Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIMB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

The molecular response of bone to growth hormone during skeletal unloading: regional differences

Hind limb elevation of the growing rat provides a good model for the skeletal changes that occur during space flight. In this model the bones of the forelimbs (normally loaded) are used as an internal control for the changes that occur in the unloaded bones of the hind limbs. Previous studies have shown that skeletal unloading of the hind limbs results in a transient reduction of bone formation in the tibia and femur, with no change in the humerus. This fall in bone formation is accompanied by a fall in serum osteocalcin (bone Gla protein, BGP) and bone BGP messenger RNA (mRNA) levels, but a rise in bone insulin-like growth factor-I (IGF-I) protein and mRNA levels and resistance to the skeletal growth-promoting actions of IGF-I. To determine whether skeletal unloading also induced resistance to GH, we evaluated the response of the femur and humerus of sham and hypophysectomized rats, control and hind limb elevated, to GH (two doses), measuring mRNA levels of IGF-I, BGP, rat bone alkaline phosphatase (RAP), and alpha 1(1)-procollagen (coll). Hypophysectomy (HPX) decreased the mRNA levels of IGF-I, BGP, and coll in the femur, but was either less effective or had the opposite effect in the humerus. GH at the higher dose (500 micrograms/day) restored these mRNA levels to or above the sham control values in the femur, but generally had little or no effect on the humerus. RAP mRNA levels were increased by HPX, especially in the femur. The lower dose of GH (50 micrograms/day) inhibited this rise in RAP, whereas the higher dose raised the mRNA levels and resulted in the appearance of additional transcripts not seen in controls. As for the other mRNAs, RAP mRNA in the humerus was less affected by HPX or GH than that in the femur. Hind limb elevation led to an increase in IGF-I, coll, and RAP mRNAs and a reduction in BGP mRNA in the femur and either had no effect or potentiated the response of these mRNAs to GH. We conclude that GH stimulates a number of markers of bone formation by raising their mRNA levels, and that skeletal unloading does not block this response, but the response varies substantially from bone to bone.

Non-NASA Center↗

Highlights from the 11-Year Record of Tropospheric Ozone from OMI/MLS and Continuation of that Long Record Using OMPS Measurements

Since October 2004 the Ozone Monitoring Instrument (OMI) and Microwave Limb Sounder (MLS) onboard the Aura satellite have provided over 11 years of continuous tropospheric ozone measurements. These OMI/MLS measurements have been used in many studies to evaluate dynamical and photochemical effects caused by ENSO, the Madden-Julian Oscillation (MJO) and shorter timescales, as well as long-term trends and the effects of deep convection on tropospheric ozone. Given that the OMI and MLS instruments have now extended well beyond their expected lifetimes, our goal is to continue their long record of tropospheric ozone using recent Ozone Mapping Profiler Suite (OMPS) measurements. The OMPS onboard the Suomi National Polar-orbiting Partnership NPP satellite was launched on October 28, 2011 and is comprised of three instruments: the nadir mapper, the nadir profiler, and the limb profiler. Our study combines total column ozone from the OMPS nadir mapper with stratospheric column ozone from the OMPS limb profiler to measure tropospheric ozone residual. The time period for the OMPS measurements is March 2012 present. For the OMPS limb profiler retrievals, the OMPS v2 algorithm from Goddard is tested against the University of Saskatchewan (USask) Algorithm. The retrieved ozone profiles from each of these algorithms are evaluated with ozone profiles from both ozonesondes and the Aura Microwave Limb Sounder (MLS). Effects on derived OMPS tropospheric ozone caused by the 2015-2016 El Nino event are highlighted. This recent El Nino produced anomalies in tropospheric ozone throughout the tropical Pacific involving increases of approximately 10 DU over Indonesia and decreases approximately 5-10 DU in the eastern Pacific. These changes in ozone due to El Nino were predominantly dynamically-induced, caused by the eastward shift in sea-surface temperature and convection from the western to the eastern Pacific.

MJO↗

Towards A Representation of Vertically Resolved Ozone Changes in Reanalyses

The Solar Backscatter Ultraviolet Radiometer (SBUV) instruments on NASA and NOAA spacecraft provide a long-term record of total-column ozone and deep-layer partial columns since about 1980. These data have been carefully processed to extract long-term trends and offer a valuable resource for ozone monitoring. Studies assimilating limb-sounding observations in the Goddard Earth Observing System (GEOS) data assimilation system (DAS) demonstrate that vertical ozone gradients in the upper troposphere and lower stratosphere (UTLS) are much better represented than with the deep-layer SBUV observations. This is exemplified by the use of retrieved ozone from the EOS Microwave Limb Sounder (EOS-MLS) instrument in the MERRA-2 reanalysis, for the period after 2004. This study examines the potential for extending the use of limb-sounding observations at earlier times and into the future, so that future reanalyses may be more applicable to the study of long-term ozone changes.Historical data are available from NASA instruments: the Limb Infrared Monitor of the Stratosphere (LIMS: 1978-1979); the Upper Atmospheric Research Satellite (UARS: 1991-1995); Sounding of the Atmosphere using Broadband Emission Radiometry (SABER: 2000-onwards). For the post EOS-MLS period, the joint NASA-NOAA Ozone Monitoring and Profiling Suite Limb Profiler (OMPS-LP) instrument was launched on the Suomi-NPP platform in 201x and is planned for future platforms. This study will examine two aspects of these data pertaining to future reanalyses. First, the feasibility of merging the EOS-MLS and OMPS-LP instruments to provide a long-term record that extends beyond the potential lifetime of EOS-MLS. If feasible, this would allow for long-term monitoring of ozone recovery in a three-dimensional reanalysis context. Second, the skill of the GEOS DAS in ingesting historical data types will be investigated. Because these do not overlap with EOS-MLS, use will be made of system statistics and evaluation using independent datasets. Impacts of using a complete ozone chemistry module will also be considered.

ML↗

High-capacity ATHLETE Offloader Mobility Constructor Concept for Human Surface Exploration

Using cross-cabled, winch-tendon four-bar frames, a new Artemis-class ATHLETE system is a multi-limbed robotic mobility platform that is designed for surface traverse, precision placement, and offloading of heavy habitats and other large human exploration payloads from high-decked landers. Building upon lessons learned from the All-Terrain Hex-Limbed Extra-Terrestrial Explorer (ATHLETE) robotic mobility system developed for Constellation Lunar Surface Systems and Evolvable Mars Campaign, a high-capacity articulated crane / lift vehicle concept has been devised that would be equipped with multi-limb six-degree-of-freedom dexterity for a variety of tasks supporting planetary surface human exploration missions and outposts. The Artemis-class ATHLETE vehicle would use any combination of three to six wheel-onlimb combinations to provide a wide “outrigger” stance to transfer loads from a high center-of-gravity on sloped terrain to low stable carry configurations for long-distance traverses, and be capable of precision docking of payloads to previously positioned elements. The new vehicle concept improves upon previous Constellation-class ATHLETE versions by allowing modular hot-swapping of individual limbs to improve maintenance and flexibility. The extreme-capacity independent limbs can individually function as single cranes, and can be delivered separately via multiple lander manifests for later congregation into self-driving “Tri-ATHLETE” vehicles after delivery to the surface. This paper provides mission architecture targets and vehicle masses for stepped payload capacity values in Earth, Mars, and Lunar gravity environments, and discusses a variety of swappable tools, including wheeled mobility attachments, grippers, excavation tools, repair fixtures, ISRU extraction, winches, block & tackle rigging combinations, 3D printheads, and construction aids.

Wilcox, Brian↗

Angioplasty or Primary Stenting for Infrapopliteal Lesions: Results of a Prospective Randomized Trial

Excellent results with small stents in coronary arteries have led endovascular therapists to their use in infrapopliteal vessels. However, to date no level I evidence exists to recommend primary stenting over infrapopliteal angioplasty alone. The aim of this randomized single-center trial was to compare their 1-year outcome. A total of 38 limbs in 35 patients with critical limb ischemia were randomized to angioplasty (22 pts) or primary stenting (16 pts). Target lesions were infrapopliteal occluded (36) or stenotic (20) lesions ranging from <2 to >15 cm in length. The mean age was 72 years. At 12 months, there was no statistical difference in survival (angioplasty, 69.3%; primary stenting, 74.7%), in limb salvage (angioplasty, 90%; primary stenting, 91.7%), or in primary and secondary patency (angioplasty, 66 and 79.5%; primary stenting, 56 and 64%) between the groups Renal insufficiency was the only significant negative predicting factor for limb salvage in both groups. In conclusion, the 1-year results for both groups were broadly similar. Stenting has its place in infrapopliteal angioplasty if the procedure is jeopardized by a dissection or recoil, but our results do not support primary stenting in all cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subintimal Angioplasty of Long Chronic Total Femoropopliteal Occlusions: Long-Term Outcomes, Predictors of Angiographic Restenosis, and Role of Stenting

Purpose: The purpose of this article is to report the results of a prospective single-center study analyzing the long-term clinical and angiographic outcomes of subintimal angioplasty (SIA) for the treatment of chronic total occlusions (CTOs) of the femoropopliteal artery. Materials and Methods: Patients with severe intermittent claudication or critical limb ischemia (CLI) were enrolled in the study. All lesions were treated with SIA and provisional stenting. Primary end points were technical success, patient survival, limb salvage, lesion primary patency, angiographic binary restenosis (>50%), and target lesion revascularization (TLR). Regular clinical and angiographic follow-up was set at 6 and 12 months and yearly thereafter. Study end points were calculated with life-table survival analysis. Proportional-hazards regression analysis with a Cox-model was applied to adjust for confounding factors of heterogeneity. Results: Between May 2004 and July 2009, 98 patients (105 limbs, patient age 69.3 {+-} 9.9 years) were included in the study. Technical success rate was 91.4% with a lesion length of 121 {+-} 77 mm. Limb-salvage and survival rates were 88.7% and 84.1% at 3 years, respectively. After 12, 24, and 36 months, primary patency was 80.1%, 42.3%, and 29.0%, angiographic binary restenosis was 37.2%, 68.6%, and 80.0%, and TLR was 84.8%, 73.0%, and 64.5%, respectively. CLI was the only adverse predictor for decreased primary patency (hazard ratio [HR] 0.36; 95% confidence interval [CI] 0.16-0.80, p = 0.012), whereas significantly less restenosis was detected after spot stenting of the entry and/or re-entry site (HR 0.31; 95% CI 0.10-0.89, p = 0.01 and HR 0.20; 95% CI 0.07-0.56, p = 0.002, respectively). Conclusions: Subintimal angioplasty is a safe and effective revascularization technique for the treatment of CTOs of the femoropopliteal artery. Provisional stenting may have a role at the subintimal entry or true lumen re-entry site.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of the Arteria Profunda Femoralis: Long-Term Angiographic and Clinical Outcomes

Purpose: This study was designed to investigate the long-term angiographic and clinical outcomes of percutaneous transluminal angioplasty (PTA) of the arteria profunda femoralis (PFA), in a series of patients suffering from critical limb ischemia (CLI) or severe intermittent claudication (IC). Methods: Our department's database was searched to identify patients who underwent PTA or bail-out stenting of the PFA. Among the study's inclusion criteria were Rutherford categories 3-6 and {>=}70% stenosis of the PFA. Only de novo stenotic lesions were assessed. Primary endpoints were technical success, angiographic lesion primary patency, angiographic binary in-lesion restenosis, and target lesion recanalization (TLR) rates. Secondary endpoints included patient survival, limb salvage, and complication rates. Patient's baseline demographics, lesion, and procedural details were analyzed. Results: Between 2001 and 2011, 20 consecutive patients (17 males) with a mean age of 73 {+-} 9 (range 53-87) years underwent PTA or bail-out stenting in 23 PFA lesions. Critical limb ischemia was the indication in eight of 20 patients (40%). The mean lesion length was 31 {+-} 9.5 mm. The procedural technical success was 100% (23/23), whereas mean time angiographic and clinical follow-up was 26.8 {+-} 24.6 months. According to the Kaplan-Meier analysis, primary patency and binary restenosis rate were 95 and 86.1% respectively up to 8 years follow-up. No TLR procedures were performed. The 8-year patient survival and limb salvage rates were 87.5 and 84.7% respectively. Conclusions: PTA or stenting of focal, stenotic, PFA lesions, in patients suffering from CLI or IC, exhibit high long-term primary patency rates, as well as low binary restenosis and TLR rates. Large, multicenter studies are required to validate these results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A unique stylopod patterning mechanism by Shox2 -controlled osteogenesis

Vertebrate appendage patterning is programmed by Hox-TALE factor-bound regulatory elements. However, it remains unclear which cell lineages are commissioned by Hox-TALE factors to generate regional specific patterns and whether other Hox-TALE co-factors exist. In this study, we investigated the transcriptional mechanisms controlled by the Shox2 transcriptional regulator in limb patterning. Harnessing an osteogenic lineage-specific Shox2 inactivation approach we show that despite widespread Shox2 expression in multiple cell lineages, lack of the stylopod observed upon Shox2 deficiency is a specific result of Shox2 loss of function in the osteogenic lineage. ChIP-Seq revealed robust interaction of Shox2 with cis-regulatory enhancers clustering around skeletogenic genes that are also bound by Hox-TALE factors, supporting a lineage autonomous function of Shox2 in osteogenic lineage fate determination and skeleton patterning. Pbx ChIP-Seq further allowed the genome-wide identification of cis-regulatory modules exhibiting co-occupancy of Pbx, Meis and Shox2 transcriptional regulators. Integrative analysis of ChIP-Seq and RNA-Seq data and transgenic enhancer assays indicate that Shox2 patterns the stylopod as a repressor via interaction with enhancers active in the proximal limb mesenchyme and antagonizes the repressive function of TALE factors in osteogenesis.

Ye, Wenduo↗

Comparison of Motion Analysis Systems in Tracking Upper Body Movement of Myoelectric Bypass Prosthesis Users

Current literature lacks a comparative analysis of different motion capture systems for tracking upper limb (UL) movement as individuals perform standard tasks. To better understand the performance of various motion capture systems in quantifying UL movement in the prosthesis user population, this study compares joint angles derived from three systems that vary in cost and motion capture mechanisms: a marker-based system (Vicon), an inertial measurement unit system (Xsens), and a markerless system (Kinect). Ten healthy participants (5F/5M; 29.6 ± 7.1 years) were trained with a TouchBionic i-Limb Ultra myoelectric terminal device mounted on a bypass prosthetic device. Participants were simultaneously recorded with all systems as they performed standardized tasks. Root mean square error and bias values for degrees of freedom in the right elbow, shoulder, neck, and torso were calculated. The IMU system yielded more accurate kinematics for shoulder, neck, and torso angles while the markerless system performed better for the elbow angles. By evaluating the ability of each system to capture kinematic changes of simulated upper limb prosthesis users during a variety of standardized tasks, this study provides insight into the advantages and limitations of using different motion capture technologies for upper limb functional assessment.

42 ENGINEERING↗

ACCELERATING WAVES IN POLAR CORONAL HOLES AS SEEN BY EIS AND SUMER

We present EIS/Hinode and SUMER/SOHO observations of propagating disturbances detected in coronal lines in inter-plume and plume regions of a polar coronal hole. The observation was carried out on 2007 November 13 as part of the JOP196/HOP045 program. The SUMER spectroscopic observation gives information about fluctuations in radiance and on both resolved (Doppler shift) and unresolved (Doppler width) line-of-sight velocities, whereas EIS 40'' wide slot images detect fluctuations only in radiance but maximize the probability of overlapping field of view between the two instruments. From distance-time radiance maps, we detect the presence of propagating waves in a polar inter-plume region with a period of 15-20 minutes and a propagation speed increasing from 130 {+-} 14 km s{sup -1} just above the limb to 330 {+-} 140 km s{sup -1} around 160'' above the limb. These waves can be traced to originate from a bright region of the on-disk part of the coronal hole where the propagation speed is in the range of 25 {+-} 1.3 to 38 {+-} 4.5 km s{sup -1}, with the same periodicity. These on-disk bright regions can be visualized as the base of the coronal funnels. The adjacent plume region also shows the presence of propagating disturbances with the same range of periodicity but with propagation speeds in the range of 135 {+-} 18 to 165 {+-} 43 km s{sup -1} only. A comparison between the distance-time radiance map of the two regions indicates that the waves within the plumes are not observable (may be getting dissipated) far off-limb, whereas this is not the case in the inter-plume region. A correlation analysis was also performed to find out the time delay between the oscillations at several heights in the off-limb region, finding results consistent with those from the analysis of the distance-time maps. To our knowledge, this result provides first spectroscopic evidence of the acceleration of propagating disturbances in the polar region close to the Sun (within 1.2 R/R{sub sun}), which provides clues to the understanding of the origin of these waves. We suggest that the waves are likely either Alfvenic or fast magnetoacoustic in the inter-plume region and slow magnetoacoustic in the plume region. This may lead to the conclusion that inter-plumes are a preferred channel for the acceleration of the fast solar wind.

79 ASTRONOMY AND ASTROPHYSICS↗

Silicone Molding and Lifetime Testing of Peripheral Nerve Interfaces for Neuroprostheses

Implantable peripheral nerve cuffs have a large application in neuroprostheses as they can be used to restore sensation to those with upper limb amputations. Modern day prosthetics, while lessening the pain associated with phantom limb syndrome, have limited fine motor control and do not provide sensory feedback to patients. Sensory feedback with prosthetics requires communication between the nervous system and limbs, and is still a challenge to accomplish with amputees. Establishing this communication between the peripheral nerves in the arm and artificial limbs is vital as prosthetics research aims to provide sensory feedback to amputees. Peripheral nerve cuffs restore sensation by electrically stimulating certain parts of the nerve in order to create feeling in the hand. Cuff electrodes have an advantage over standard electrodes as they have high selective stimulation by bringing the electrical interface close to the neural tissue in order to selectively activate targeted regions of a peripheral nerve. In order to further improve the selective stimulation of these nerve cuffs, there is need for finer spatial resolution among electrodes. One method to achieve a higher spatial resolution is to increase the electrode density on the cuff itself. Microfabrication techniques can be used to achieve this higher electrode density. Using L-Edit, a layout editor, microfabricated peripheral nerve cuffs were designed with a higher electrode density than the current model. This increase in electrode density translates to an increase in spatial resolution by at least one order of magnitude. Microfabricated devices also have two separate components that are necessary to understand before implantation: lifetime of the device and assembly to prevent nerve damage. Silicone molding procedures were optimized so that devices do not damage nerves in vivo, and lifetime testing was performed on test microfabricated devices to determine their lifetime in vivo. Future work of this project would include fabricating some of the designed devices and seeing how they compare to the current cuffs in terms of their electrical performance, lifetime, shape, and mechanical properties.

59 BASIC BIOLOGICAL SCIENCES↗

Parameterization retrieval of trace gas volume mixing ratios from Airborne MAX-DOAS

We present a parameterization retrieval of volume mixing ratios (VMRs) from differential slant column density (dSCD) measurements by Airborne Multi-AXis Differential Optical Absorption Spectroscopy (AMAX-DOAS). The method makes use of the fact that horizontally recorded limb spectra (elevation angle 0°) are strongly sensitive to the atmospheric layer at instrument altitude. These limb spectra are analyzed using reference spectra that largely cancel out column contributions from above and below the instrument, so that the resulting limb dSCDs, i.e., the column integrated concentration with respect to a reference spectrum, are almost exclusively sensitive to the atmospheric layers around instrument altitude. The conversion of limb dSCDs into VMRs is then realized by calculating box air mass factors (Box-AMFs) for a Rayleigh atmosphere and applying a scaling factor constrained by O 4 dSCDs to account for aerosol extinction. An iterative VMR retrieval scheme corrects for trace gas profile shape effects. Benefits of this method are (1) a fast conversion that only requires the computation of Box-AMFs in a Rayleigh atmosphere; (2) neither local aerosol extinction nor the slant column density in the DOAS reference (SCD ref ) needs to be known; and (3) VMRs can be retrieved for every measurement point along a flight track, thus increasing statistics and adding flexibility to capture concentration gradients. Sensitivity studies are performed for bromine monoxide (BrO), iodine monoxide (IO) and nitrogen dioxide (NO 2 ), using (1) simulated dSCD data for different trace gas and aerosol profiles and (2) field measurements from the Tropical Ocean tRoposphere Exchange of Reactive halogen species and Oxygenated VOC (TORERO) field experiment. For simulated data in a Rayleigh atmosphere, the agreement between the VMR from the parameterization method (VMR para ) and the true VMR (VMR true ) is excellent for all trace gases. Offsets, slopes and R 2 values for the linear fit of VMR para over VMR true are, respectively (0.008 ± 0.001) pptv, 0.988 ± 0.001, 0.987 for BrO; (-0.0066 ± 0.0001) pptv, 1.0021 ± 0.0003, 0.9979 for IO; (-0.17 ± 0.03) pptv, 1.0036 ± 0.0001, 0.9997 for NO 2 . The agreement for atmospheres with aerosol shows comparable R 2 values to the Rayleigh case, but slopes deviate a bit more from one: (0.093 ± 0.002) pptv, 0.933 ± 0.002, 0.907 for BrO; (0.0021 ± 0.0004) pptv, 0.887 ± 0.001, 0.973 for IO; (8.5 ± 0.1) pptv, 0.8302 ± 0.0006, 0.9923 for NO 2 . VMR para from field data are further compared with optimal estimation retrievals (VMR OE ). Least orthogonal distance fit of the data give the following equations: BrO para = (0.1 ± 0.2) pptv + (0.95 ± 0.14) × BrO OE ; IO para = (0.01 ± 0.02) pptv + (1.00 ± 0.12) × IO OE ; NO 2para = (3.9 ± 2.5) pptv + (0.87 ± 0.15) × NO 2OE . Overall, we conclude that the parameterization retrieval is accurate with an uncertainty of 20 % for IO, 30 % for BrO and NO 2 , but not better than 0.05 pptv IO, 0.5 pptv BrO and 10 pptv NO 2 . Finally, the retrieval is applicable over a wide range of atmospheric conditions and measurement geometries and not limited to the interpretation of vertical profile measurements in the remote troposphere.

54 ENVIRONMENTAL SCIENCES↗

Mariner 9 ultraviolet spectrometer experiment: Mars atomic oxygen 1304-Angstrom emission

Selected results are presented for a considerable quantity of Mariner 9 1304-A data for the first 100 revolutions from both the bright limb and disk of Mars. The limb data suggest that the exospheric temperature is less than it was in 1969 when Mariners 6 and 7 encountered the planet. Similar (O) concentrations (0.5 to 1%) are derived for a temperature of about 300 K. Structure in the limb profiles below 200 km suggests the possibility that about 0.2 kR of the observed approximately 0.8 kR near 150 km is due to dissociative excitation of CO2. Significant differences in selected limb profiles suggest that local as well as random variations in (O) occur.

Strickland, D. J.↗

Mariner 9 ultraviolet spectrometer experiment - Mars atomic oxygen 1304-A emission.

Selected results are presented for an analysis of Mariner 9 1304-A data from the first 100 passes. Based on a comparison of limb data, the exospheric temperature appears lower on several Mariner 9 passes than when Mariner 6 and 7 encountered the planet in 1969. Temperatures of 300 and 350 K are considered in the atmospheric modeling. At 300 K, derived values of the atomic oxygen concentration are typically between 0.5 and 1% of the total density at 135 km, based on fitting theoretical intensities to limb data from several passes. Structure in the limb data below 200 km suggests the possibility that approximately 0.2 kR of the observed approximately 0.8 kR near 150 km is due to dissociative excitation of CO2. There is variability in limb profiles, thus indicating changes in the O distribution with time. The variability does not appear to follow a recognizable pattern. Interpretation of the 1304-A disk data shows a correlation in intensity with the 10.7-cm solar flux and larger O concentrations in the afternoon than in the morning. The correlation in intensity with the 10.7-cm flux is probably due largely to variation in the solar 1304-A fluxes.

Strickland, D. J.↗

Correcting airborne scanning infrared radiometer measurements for atmospheric effects

Two techniques were developed for determining atmospheric corrections from observations made by a scanning radiometer. Both techniques depend on knowing the radiometer's limb function. The limb function for an RS-18 scanning radiometer is derived from calculations made with a radiation model and used to demonstrate the techniques. One technique requires observations made over an isothermal water surface within the area being remotely sensed. The other technique does not depend on an isothermal water surface but requires a boat measurement of radiometric sea surface temperature within the area being remotely sensed. The radiation model used to derive the limb function does not account for the effects of atmospheric particulates on the correction. It is hypothesized that the effect of particulates on the limb function derived in this study is negligible, and therefore the technique essentially obtains the total correction. The techniques developed can be used over land provided that a section of isothermal land exists within the experiment area or that a radiometric measurement of surface temperature is made at the surface.

Boudreau, R. D.↗

Comments on the quiet sun brightness distribution at 1.2 mm wavelength

Data on the center-to-limb brightness distribution of the quiet sun at 1.2-mm wavelength are reanalyzed. The observed brightness distribution at this wavelength is plotted along the equatorial direction and analyzed to determine whether it is uniform, limb-brightened, or limb-darkened. It is concluded that at the present time, there is no evidence for a uniform or limb-brightened distribution at 1.2 mm from either an observational or theoretical point of view.

Kundu, M. R.↗

The vertical cloud structure of Jupiter from 5 micron measurements

From 5-micron high-spatial-resolution images of Jupiter, flux-frequency histograms of the equatorial region show a trimodal distribution of brightness temperatures. Combined with limb-darkening measurements, a three-layer cloud model for Jupiter is developed. The highest, coldest clouds, apparently homogeneous and displaying relatively little limb darkening, cover the zones. These clouds are not present over the belts, allowing observational access to deeper regions. The belts appear heterogeneous: small, localized hot areas show enhanced limb darkening, while much of the belt is distinctly cooler and exhibits shallower limb darkening. These belt properties can be explained by a cool emitting layer superposed upon a hot, dense cloud deck.

Terrile, R. J.↗