Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Isotope Program”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Fuel Fabrication Specification Impact Analysis for NBSR LEU Conversion

As part of a national initiative to enhance nuclear security and reduce proliferation risks, significant efforts have been undertaken by the National Nuclear Security Administration Material Management and Minimization Office of Reactor Conversion Program to convert U.S. high performance research reactors (USHPRRs) from the use of highly enriched uranium (HEU) to low-enriched uranium (LEU), including the National Bureau of Standards Reactor (NBSR). The current plan is to procure LEU fuel assemblies from commercial fabricators according to fuel specifications tailored for each USHPRR. The analysis conducted at Brookhaven National Laboratory was part of an effort to identify the sources of uncertainty in the fuel specifications that may impact the performance of the NBSR core after its conversion and, in particular, to assess the range of acceptable tolerance limits from the perspective of core safety and reactor performance. Using the stochastic neutronics code MCNP 6.2, the variations in important NBSR neutronics characteristics were analyzed as a function of the specification parameters independently and in combination. The important NBSR specification parameters analyzed were the fuel isotopic composition, the amount of impurity content in cladding, the fuel plate thickness, and the fuel element 235U mass loading. The range of variation of each specification parameter was based on the technical specification limit or available as-fabricated assay data and uncertainties. The NBSR neutronics characteristics selected for analysis were the reactor reactivity characteristics at equilibrium and the equilibrium fuel cycle length. Results show that with variations in the fabrication parameters of the as-fabricated U-10Mo fuel within the specification limitations, the excess reactivity of the NBSR LEU core remains well below the 15% Δk/k technical specification limit, and the shutdown margin is always significantly greater than the required 0.68% Δk/k. This ensures that the NBSR can be operated safely and reliably shut down for all analyzed cases within the specified fabrication limits after the LEU conversion. In the prototypic case, the fuel cycle length was 1.5 days longer than the targeted 38.5 days. In a credible worst-case scenario, where all low-reactivity parameters were combined, the fuel cycle length was reduced to 35.5 days, which is still considered manageable for reactor operations. Variations in cycle length are primarily driven by changes in 235U loading, with other parameters having secondary effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High Radiation Environment Nuclear Fragment Separator Magnet

Superconducting coils wound with HTS conductor can be used in magnets located in a high radiation environment. NbTi and Nb 3 Sn superconductors must operate at 4.5 K or below where removal of heat is less efficient. The HTS conductor can carry significant current at higher temperatures where the Carnot efficiency is significantly more favorable and where the coolant heat capacity is much larger. Using the HTS conductor the magnet can be operated at 40 K. This project examines the use of HTS conductor for the Michigan State University Facility For Rare Isotope Beams (FRIB) fragment separator dipole magnet which bends the beam by 30° and is located in a high radiation region that will not be easily accessible. Two of these magnets are needed to select the chosen isotope. There are a number of technical challenges to be addressed in the design of this magnet. The separator dipole is 2 m long and subtends a large angle. The magnet should keep a constant transverse field profile along its beam reference path. Winding coils with a curved inner segment is difficult as the conductor will tend to unwind during the process. In the Phase I project two approaches to winding the conductor were examined. The first was to wind the coils with curved sections on the inner and outer segments with the inner segment wound with negative curvature. The alternate approach was to use a straight segment on the inner segment to avoid negative curvature. In Phase I coils with a limited number of turns were successfully wound and tested at 77 K for both coil configurations. The Phase II program concentrated on the design, coil winding procedures, structural analysis, prototyping and testing of an HTS curved dipole coil at 40 K with a heat load representative of the radiation environment. One of the key criteria of the design of this magnet is to avoid the use of organic materials that would degrade rapidly in radiation. The Lorentz forces expected from the coils interacting with the magnetic field are large and in order minimize the deformation of the coils, mechanical support must be provided. Since the support structure cannot be made of organic materials with minimal thermal conductivity, an optimization was explored comparing the amount of coil deformation that can be tolerated and the amount of heat leakage that can be endured. A test coil containing 500 m of HTS was constructed to be tested at the 40 K operating temperature. The anticipated heat load was simulated with heater strips to demonstrate that the heat could be removed and that the coil can operate in a stable state. The FRIB project has decided that using HTS coils for this magnet was too risky considering their time and funding constraints and has opted for a more conservative approach with conventional coils. As an outcome of this STTR project, it is likely that HTS coils operating at higher temperatures will have beneficial applications for future accelerator projects.

40 K↗

Extreme Temperature Sample Environment for Materials Research Using Neutron Scattering

Extreme temperatures and non-equilibrium materials are both central to Department of Energy’s (DOE) mission of addressing grand challenges in emerging energy and advanced materials technologies. The goal of this project is to develop and perfect a system for studying materials in extreme and non-equilibrium conditions using neutron scattering. Neutron scattering has many advantages in the study of materials structure including the ability to use isotopic substitution to determine partial structure factors. When used at a pulsed neutron source, the potential for event-based detection can enable a stroboscopic technique to interrogate very short lived metastable states in supercooled liquids. The work performed in this Phase I project included: (i) literature reviews and discussions with beamline scientists to establish key requirements for the instrument, (ii) laboratory-based research at Materials Development, Inc. (MDI) to test design concepts, modify control software and model designs, (iii) feasibility experiments and measurements on a prototype sample at the Spallation Neutron Source, and (iv) analysis of the results and design of the proposed Phase II instrument. The results of the work show that the proposed approach is viable and provides a strong basis for the Phase II instrument design and Phase III commercialization. MDI participated in the DOE Commercialization Assistance Program with the Larta Institute (Larta) to accelerate commercial sales of the instruments. The market research identified a served available market of ~13M including sales to beamlines, university research laboratories, and industrial glass and materials businesses. Over the ca. 10 year product life cycle, MDI expects to sell instruments with a cumulative net present value profit of approximately 5M.

47 OTHER INSTRUMENTATION↗

Disposal Process for High Activity Sources by a University through the U.S. Dept. of Energy's Off-Site Source Recovery Project - 12076

Sealed radioactive sources are used in a wide variety of applications by a large number of license holders in the Unites States. Applications range from low-activity calibration sources to high-activity irradiators for engineering, research, or medical purposes. This paper describes and evaluates the safety and security measures in place for disused sealed sources, in particular of high activity sealed sources at the end of their operational life-time. The technical, radiation protection, and financial challenges for licensees and the Competent Authorities are reviewed from the point of view of the license holder. As an example, the waste management processes and the chain of custody for disused research irradiator sources are followed from extraction from the irradiator facility to the source disposal or recycling contractor. Possible safety and security concern in the waste disposal process are investigated in order to identify improvement potential for radiation protection or source security. Two shipments of disused sealed sources from Colorado State University (CSU) have been conducted through the CSU Radiation Control Office (RCO) in the last two years, with a third shipment expected to be completed by the end of November 2011. Two of the sources shipped are considered 'high' activity and exceed the U.S. NRC limits requiring increased controls for security purposes. Three sources were shipped in 2009 and ten more are expected in 2011. A total activity of 117.3 GBq was shipped in 2009. Nine sources were recently shipped in October 2011 through a third party waste broker where the total activity was 96.34 GBq. The last source is scheduled for shipment no later than 30 November 2011 and contains an activity of 399.96 GBq. Radiation waste disposal of high activity sources in large shields with unknown manufacturers, serial numbers, or model numbers is an arduous process requiring multiple contacts with various state and federal agencies. DOE's OSRP has made it possible for CSU to dispose of older unused sources in an economically viable way. Disposal of multiple sources all at once was not an option prior to the establishment of the SCATR program. While CSU was able to dispose of sealed sources when funds were available, the cost to the University would have been prohibitive for this type of mass removal and disposal of radiation sources initiated within this initiative. Where we estimate a cost of about $130 k to ship these sources otherwise, CSU's contribution of $21 k realized a significant savings in what would have been an impossible disposal cost. Removing unused radiation sources from CSU has realized a cost savings while removing a potential security threat. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Gaussian Process Optimization of Sensitivity-Based Similarity Metrics between New Nuclear Applications and New/Existing Benchmarks [Slides]

This presentation discusses Nuclear Criticality Safety (NCS) and how designing safe, new nuclear criticality experiments requires expert judgement, which could take years of experience. Sensitivity/uncertainty (S/U) analysis can be utilized by less experienced individuals to conservatively estimate uncertainties in important parameters, such as k eff , in newly proposed nuclear experiments. The presentation poses the question of how this analysis can be performed and states that the answer lies in matching new nuclear experiments with existing benchmark experiments using similarity metrics. By increasing the criticality safety of the application in this work, higher mass limits could be used in PF-4 operations. Additionally, the presentation discusses MCNP6.2®, Whisper-1.1, the software that can be used in this analysis. Also discussed is the fact that International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmarks rarely match new nuclear applications and that there are significant differences in given set of materials and/or geometry. If there are no benchmarks that match the application, the presentation discusses the possibility of creating new benchmarks. In conclusion, this work presents a Gaussian process (GP) optimization scheme that was used to generate new benchmarks with the highest sensitivity-based similarity metrics to user-defined nuclear applications. The Gaussian process optimization successfully designed 3 new experimental benchmarks that were highly correlated to the application of interest and had k eff values near critical. Optimization over c k,i-r has shown that investigating specific isotope reactions for different applications is crucial to designing benchmark experiments. Partial contribution from Pu dominates c k similarity metric. Future work includes testing new stand-alone similarity metrics or new combinations of similarity metrics as the design criterion of this optimization – design criterion is application dependent.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-C-9A-02: Structured Noise Index as An Automated Quality Control for Nuclear Medicine: A Two Year Experience

Purpose: Flood-field uniformity evaluation is an essential element in the assessment of nuclear medicine (NM) gamma cameras. It serves as the central element of the quality control (QC) program, acquired and analyzed on a daily basis prior to clinical imaging. Uniformity images are traditionally analyzed using pixel value-based metrics which often fail to capture subtle structure and patterns caused by changes in gamma camera performance requiring additional visual inspection which is subjective and time demanding. The goal of this project was to develop and implement a robust QC metrology for NM that is effective in identifying non-uniformity issues, reporting issues in a timely manner for efficient correction prior to clinical involvement, all incorporated into an automated effortless workflow, and to characterize the program over a two year period. Methods: A new quantitative uniformity analysis metric was developed based on 2D noise power spectrum metrology and confirmed based on expert observer visual analysis. The metric, termed Structured Noise Index (SNI) was then integrated into an automated program to analyze, archive, and report on daily NM QC uniformity images. The effectiveness of the program was evaluated over a period of 2 years. Results: The SNI metric successfully identified visually apparent non-uniformities overlooked by the pixel valuebased analysis methods. Implementation of the program has resulted in nonuniformity identification in about 12% of daily flood images. In addition, due to the vigilance of staff response, the percentage of days exceeding trigger value shows a decline over time. Conclusion: The SNI provides a robust quantification of the NM performance of gamma camera uniformity. It operates seamlessly across a fleet of multiple camera models. The automated process provides effective workflow within the NM spectra between physicist, technologist, and clinical engineer. The reliability of this process has made it the preferred platform for NM uniformity analysis.

07 ISOTOPE AND RADIATION SOURCES↗

VERIFICATION MEASUREMENTS OF THE MASS AND ENRICHMENT OF URANIUM OXIDE CARD SOURCES

Measurements were performed to determine the mass and enrichment of 10 uranium oxide (U3O8) card sources. The measurements and analysis were completed as a verification of the card sources in support of Oak Ridge National Laboratory’s nuclear material control and accountability program. Although these cards are not nationally accredited as a nuclear standard, they are used as a working reference for measurements, such as holdup. The uranium card source measurements were taken with a broad energy germanium detector and the Genie 2000 Gamma Acquisition and Analysis software. A complete characterization of each of the 10 uranium card sources was performed using the 4 characteristic full energy peaks of 235U. Using the In Situ Object Counting System software to determine the mathematical efficiency of the measurement, the mass of 235U in each card was determined. The 235U mass in each card ranged from 10.42 to 12.63 g with a systematic error between 0.76 and 0.95 g and a random error of 0.01 g for each card source. The Multi-Group Analysis for Uranium (MGAU) software and the Fixed-Energy, Response Function Analysis with Multiple Efficiency (FRAM) isotopic analysis software were used to determine the isotopic composition of the uranium cards. The measured enrichment was compared to the declared enrichment for each card, with uncertainties ranging from 2.7% to 4.3% for the MGAU analysis and 2.3% to 4.1% for the FRAM analysis. This is a good example of how a well-benchmarked mathematical calibration method can be useful in characterizing uranium sources.

Hunneke, Rachel↗

Requalification of historical intermediate level waste (ILW) for the repository KONRAD on basis of non destructive assay (NDA) and re-evaluated nuclide vectors - 15289

The storage facility for ILW of the HDB contains a large number of historical waste products in 200-l drum geometry, which were produced in the 1970's to the 1990's. In the next years more ILW will be treated and stored at HDB, exceeding the storage capacity of the ILW store. All waste products produced at HDB are treated according to the acceptance criteria of the repository KONRAD and are planned to final storage in this repository. In order to qualify the waste materials for final storage in KONRAD and to remove parts of the inventory from the storage chambers this project was started. The main issues of the project, which will be accompanied by the regulator, are product control measures like gas chromatographic analyses of remotely sampled gas syringes and non destructive assay techniques like?-spectrometry and neutron-analytics. The product control is followed by declaration on the basis of re-evaluated nuclide vectors and a repackaging of the drums in licensed containers. The packaging concept includes a 400-l drum as qualified over-pack, because several of the historical drums cannot be qualified as IP-II or type A package. The annual space between the two drums is filled with quartz sand for stability and additional shielding. The drum set is afterwards inserted into a qualified UBA-container provided by GNS. In the case that the product control measures and the reassessment of the declarations result in a violation of the activity limits of the relevant acceptance criteria for KONRAD, the respective drum has to be physically re-qualified after correspondence with the surveillance authorities. This program will be applied to a fraction of approx. 400 canisters, which were selected on the basis of several quality aspects like dose rate below 100 mSv/h, nuclide inventory below 100 A2 according to paragraph 201 of TS-R-1 and well-known waste composition. In the future more waste products will be treated in the same way, if approved containers exist for the inventory. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Generation of Enrichment-Dependent Thermal Neutron Scattering Data

This work details the generation of enrichment-dependent thermal neutron scattering cross sections for several crucial uranium fuel compounds. The evaluations of the thermal scattering law (TSL) and associated cross sections for uranium dioxide (UO 2 ), uranium carbide (UC), and uranium nitride (UN) were performed using standard ab initio lattice dynamics (AILD) methods. The data for uranium metal was produced using a novel hybrid approach of molecular dynamics combined with lattice dynamics methods. 235 U enrichments of 5%, 10% (LEU+), 19.75% (HALEU), 93% (HEU), and 100% were considered, in addition to natural uranium. The enrichment-dependent masses and free atom cross sections were used in the generation of elastic and inelastic thermal neutron scattering cross sections, while the calculation of the phonon density of states (DOS) and resulting TSL considered only the natural isotopic composition of uranium. The use of an identical DOS for all enrichments is expected to have minimal impact on the final data, as the small change in uranium mass should not significantly affect lattice vibrations. The cross sections are shown to exhibit significant dependence on 235 U enrichment. The submission of this data to the National Nuclear Data Center (NNDC) for release in the ENDF/B-VIII.1 database should support the design of advanced reactor concepts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of 235 U Isotopic Dilution with the Addition of Depleted Uranium to Supernatant Liquid Waste

Laboratory-scale results on experiments performed to examine the feasibility of isotopic dilution of 235 U in supernatant liquid storage tanks at the Savannah River Site are described. Here, the isotopic dilution tests were accomplished by adding an alkaline depleted uranium solution to small portions of simulated and actual storage tank waste solutions with enriched 235 U compositions. Based on the laboratory observations, recommendations were made, which involved the addition of significant quantities of uranyl carbonate solution to more than 4 million l of 235 U enriched waste stored in tank 43H at the site to reduce the risk for criticality.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New Capability at ORNL: High Precision Uranium Titration

Destructive analytical measurements establish a nuclear facility’s nuclear material inventory and inventory differences for Nuclear Material Accountancy and Control. A nuclear laboratory’s ability to perform accurate high-precision analytical measurements is key for tracking large inventories within a facility’s material balance areas and during production to track material movement through dynamic processes. For uranium, these measurements are made by using several established high-precision measurement protocols. These include isotope dilution mass spectrometry, gravimetry, and potentiometric titrations. Whatever measurement technique a nuclear lab chooses to use, reference materials (RMs) with certified attributes and accompanying uncertainties are used to calibrate measurement systems, and are the cornerstone for accurate results. In addition to calibration, RMs provide for metrological traceability, are used for method development and validation, and thus provide critical evaluations of the appropriateness and performance of analytical processes used. Evaluations may include validation that a method is fit-for-purpose, quantification of systematic and random biases, and the evaluation of long-term and short-term performance metrics. High-precision measurement techniques require that measured attributes be certified to a high degree of precision in the RMs used—ultimately, to a higher degree than that of the measurement technique itself. The US authority on the production of special nuclear material Certified Reference Materials is the NBL Program Office (NBLPO), formally known as New Brunswick Laboratory (NBL). The NBLPO is responsible for the sales and distribution of existing NBL certified reference materials (CRMs) and for the production of the next generation of nuclear RMs. To accomplish its mission, NBLPO is establishing key base capabilities within the DOE laboratory complex that formerly existed at the NBL laboratory. The Nuclear Analytical Chemistry (NAC) section within the Chemical Sciences Division (CSD) at Oak Ridge National Laboratory (ORNL) is currently working with NBLPO to set up laboratory and measurement capabilities to provide measurements and capabilities for production and/or recertification of existing and future CRMs for uranium assay. The NBL-developed high-precision titration (HPT) method is a critically-evaluated, extremely precise and accurate primary method utilized for the determination of uranium content in a variety of uranium materials. The HPT method, combined with detailed balance weighing protocols, provides for an analytical methodology that is unsurpassed in precision and one in which all sources of error have been evaluated, a requirement of CRM certification. HPT capability within the United States was lost with the closure of the labs at NBL. The NAC has been collaborating with NBLPO to stand up and demonstrate the capability to perform uranium assay via HPT at ORNL. HPT can produce results with an expanded uncertainty of approximately 0.01% for pure uranium compounds, with typical precisions of <0.006%. The major tasks required to stand up the method at ORNL were the refurbishment of a dedicated lab and equipment setup, procedure development, analyst training, establishing method-specific quality assurance, and qualification of an analyst to perform the method. This report summarizes these tasks, outlines the documents drafted, and gives the outcome of the qualification titrations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Preliminary Assessment of the Impact on Reactor Vessel dpa Rates Due to Installation of a Proposed Low Enriched Uranium (LEU) Core in the High Flux Isotope Reactor (HFIR)

An assessment of the impact on the High Flux Isotope Reactor (HFIR) reactor vessel (RV) displacements-per-atom (dpa) rates due to operations with the proposed low enriched uranium (LEU) core described by Ilas and Primm has been performed and is presented herein. The analyses documented herein support the conclusion that conversion of HFIR to low-enriched uranium (LEU) core operations using the LEU core design of Ilas and Primm will have no negative impact on HFIR RV dpa rates. Since its inception, HFIR has been operated with highly enriched uranium (HEU) cores. As part of an effort sponsored by the National Nuclear Security Administration (NNSA), conversion to LEU cores is being considered for future HFIR operations. The HFIR LEU configurations analyzed are consistent with the LEU core models used by Ilas and Primm and the HEU balance-of-plant models used by Risner and Blakeman in the latest analyses performed to support the HFIR materials surveillance program. The Risner and Blakeman analyses, as well as the studies documented herein, are the first to apply the hybrid transport methods available in the Automated Variance reduction Generator (ADVANTG) code to HFIR RV dpa rate calculations. These calculations have been performed on the Oak Ridge National Laboratory (ORNL) Institutional Cluster (OIC) with version 1.60 of the Monte Carlo N-Particle 5 (MCNP5) computer code.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status of HEU-Pb in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook

The Department of Energy invests tens of millions of dollars each year to develop the next generation of nuclear engineering modeling & simulation (M&S) tools. These tools are used to analyze advanced reactor designs and the safety of current nuclear operations. As computers become more powerful, we are able to enhance resolution in our calculations. This improved resolution is taking us to a point where the limitations of simulation capability are in the quality of data, including our ability to quantify the uncertainty and sensitivity of the data. In order to model systems of interest with increasing accuracy, the industry must improve key nuclear data measurements. Thus, M&S tools need evaluated and quality-assured experimental data for validation purposes. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) compiles and evaluates experiment data in a handbook that can be used by criticality safety engineers and others to validate computer codes and cross-section libraries at nuclear facilities. Both critical and subcritical experiments are included in the handbook. Figure 1 organizes all the benchmark evaluations that have been performed by the isotope of interest, in this case Pb, and the average neutron energy the system. Compared to other isotopes of interest for nuclear applications, there are few benchmark evaluations for Pb systems. The lack of integral measurements to determine errors in Pb cross-section data has caused the latest nuclear cross-section libraries to over/underestimate k eff compared to experimental results. Therefore, this evaluation fills an important knowledge gap in benchmark evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER-517: Molybdenum Optimized Benchmark System Demonstrating Integral Correlations (MOBY DICK)

Nuclear criticality experiments are essential to the validation of nuclear data used in simulation software. The quality of nuclear data becomes paramount as simulation software becomes more relied upon for criticality safety studies and designs of nuclear systems. To improve the quality of nuclear data, experimenters can design critical experiments that are sensitive to isotope reaction pairs in materials of interest. The efforts conducted by the Organisation for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA) Working Party on Nuclear Criticality Safety (WPNCS) Subgroup 8: Preservation of Expert Knowledge and Judgement Applied to Criticality Benchmarks (SG8) to categorize benchmarks according to their usefulness for nuclear data validation have been of great importance. Based on the OECD studies benchmark experiments included in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook are concisely used by nuclear data evaluators, criticality safety engineers and others to validate nuclear data and simulation results. A lack of benchmarks sensitive to molybdenum in the (ICSBEP), particularly in the intermediate range, was noted by Los Alamos National Laboratory (LANL), the French Institut de Radioprotection et de Sûreté Nucléaire (IRSN), and Y-12 National Security Site prompting them to submit a joint integral experiment request to the Nuclear Criticality Safety Program (NCSP) in 2019. The request included both HEU and Plutonium systems in order to validate differential nuclear data focusing on the intermediate energy range but also includes thermal and fast configurations. This document represents the preliminary design work for a series of molybdenum integral experiments known as Molybdenum Optimized Benchmark System Demonstrating Integral Correlations (MOBY DICK).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recent Metallic Fuel Data Recovery in FIPD

The Metallic Fuels Irradiation and Physics Database (FIPD) [1] is an organized collection of metallic fuel test pin data (U-xPu-yZr, = 0 ~ 28; y = 2 ~ 10) and documentation available to industry. FIPD mainly contains three types of data: (1) Fuel pin fabrication data, including fuel slug diameter, fuel slug length, cladding diameter, smear density, etc. (2) Fuel pin operation conditions, including axial distributions for power, temperatures, fluences, burnup, and isotopic densities, etc. and (3) Fuel pin post-irradiation examination (PIE) data, including fission gas release and gas chemistry, profilometry, and neutron radiography, etc. The operating conditions for pins with PIE data available in FIPD span significant ranges across key parameters. The fuel peak burnup extends from less than 5% up to 20 at%. The cladding peak temperature varies from about 490°C to 660°C. Finally, the cladding peak DPA shows a wide range from less than 5 to 120. These broad ranges reflect the diverse testing conditions and operational parameters captured in the available PIE data. More detail about FIPD can be found in ref. [2]. The database development is an ongoing effort covering metallic fuel experiments from the Experimental Breeder Reactor II (EBR-II) and the Fast Flux Test Facility (FFTF). As reported in the ref. [3, 4], most of the PIE data generated during the IFR program [5] has been collected, reviewed, processed, and integrated into FIPD. The most recently added PIE data can be found in ref. [4], which shows the collection of over 95% of the PIE data by the time of this paper. The recent improvements to the database are summarized in this paper.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Criticality Safety Validation of Scale 6.1

The computational bias of criticality safety computer codes must be established through the validation of the codes to critical experiments. A large collection of suitable experiments has been vetted by the International Criticality Safety Benchmark Experiment Program (ICSBEP) and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). A total of more than 350 cases from this reference have been prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID) maintained by the Reactor and Nuclear Systems Division at Oak Ridge National Laboratory. The performance of the KENO V.a and KENO-VI Monte Carlo codes within the Scale 6.1 code system with ENDF/B-VII.0 cross-section data in 238-group and continuous energy is assessed using the VALID models of benchmark experiments. The TSUNAMI tools for sensitivity and uncertainty analysis are utilized to examine some systems further in an attempt to identify potential causes of unexpected results. The critical experiments available for validation of the KENO V.a code cover eight different broad categories of systems. These systems use a range of fissile materials including a range of uranium enrichments, various plutonium isotopic vectors, and mixed uranium-plutonium oxides. The physical form of the fissile material also varies and is represented as metal, solutions, or arrays of rods or plates in a water moderator. The neutron energy spectra of the systems also vary and cover both fast and thermal spectra. Over 300 of the total cases used utilize the KENO V.a code. The critical experiments available for the validation of the KENO-VI code cover three broad categories of systems. The fissile materials in the systems vary and include high and intermediate-enrichment uranium and mixed uranium/plutonium oxides. The physical form of the fissile material is either metal or rod arrays in water. As with KENO V.a, both fast and thermal neutron energy spectra are represented in the systems considered. The results indicate generally good performance of both the KENO V.a and KENO-VI codes across the range of systems analyzed. The bias of calculated k{sub eff} from expected values is less than 0.9% {Delta}k in all cases. All eight categories of experiments show biases of less than 0.5% {Delta}k in KENO V.a with the exception of intermediate enrichment metal systems using the 238-group library. The continuous energy library generally manifests lower biases than the multi-group data. The KENO-VI results show slightly larger biases, though this may primarily be the result of modeling systems with more geometric complexity, which are more difficult to describe accurately, even with a generalized geometry code like KENO-VI. Several additional conclusions can be drawn from the results of this validation effort. These conclusions include that the TSUNAMI tools can be used successfully to explain the cause of aberrant results, that some evaluations in the IHECSBE should be updated to provide more rigorous expected k{sub eff} values and uncertainties, and that potential cross-section errors can be identified by detailed review of the results of this validation. It also appears that the overall cross-section uncertainty as quantified through the Scale covariance library is overestimated. Overall, the KENO V.a and KENO-VI codes are shown to provide consistent, low bias results for a wide range of physical systems of potential interest in criticality safety applications.

Marshall, William BJ J↗

Criticality Safety Validation of SCALE 6.1 (Revised)

The computational bias of criticality safety computer codes must be established through the validation of the codes to critical experiments. A large collection of suitable experiments has been vetted by the International Criticality Safety Benchmark Experiment Program (ICSBEP) and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (IHECSBE). A total of more than 350 cases from this reference have been prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID) maintained by the Reactor and Nuclear Systems Division at Oak Ridge National Laboratory. The performance of the KENO V.a and KENO-VI Monte Carlo codes within the SCALE 6.1 code system with ENDF/B-VII.0 cross-section data in 238-group and continuous energy is assessed using the VALID models of benchmark experiments. The TSUNAMI tools for sensitivity and uncertainty analysis are utilized to examine some systems further in an attempt to identify potential causes of unexpected results. The critical experiments available for validation of the KENO V.a code cover eight different broad categories of systems. These systems use a range of fissile materials including a range of uranium enrichments, various plutonium isotopic vectors, and mixed uranium/plutonium oxides. The physical form of the fissile material also varies and is represented as metal, solutions, or arrays of rods or plates in a water moderator. The neutron energy spectra of the systems also vary and cover both fast and thermal spectra. Over 300 of the total cases used utilize the KENO V.a code. The critical experiments available for the validation of the KENO-VI code cover three broad categories of systems. The fissile materials in the systems vary and include high- and intermediate-enrichment uranium and mixed uranium/plutonium oxides. The physical form of the fissile material is either metal or rod arrays in water. As with KENO V.a, both fast and thermal neutron energy spectra are represented in the systems considered. The results indicate generally good performance of both the KENO V.a and KENO-VI codes across the range of systems analyzed. The bias of calculated k eff from expected values is less than 0.9% Δk in all cases. All eight categories of experiments show biases of less than 0.5% Δk in KENO V.a with the exception of intermediate enrichment metal systems using the 238-group library. The continuous energy library generally manifests lower biases than the multigroup data. The KENO-VI results show slightly larger biases, though this may primarily be the result of modeling systems with more geometric complexity, which are more difficult to describe accurately, even with a generalized geometry code like KENO-VI. Several additional conclusions can be drawn from the results of this validation effort. These conclusions include that the TSUNAMI tools can be used successfully to explain the cause of aberrant results, that some evaluations in the IHECSBE should be updated to provide more rigorous expected k eff values and uncertainties, and that potential cross-section errors can be identified by detailed review of the results of this validation. It also appears that the overall cross-section uncertainty as quantified through the SCALE covariance library is overestimated. Overall, the KENO V.a and KENO-VI codes are shown to provide consistent, low-bias results for a wide range of physical systems of potential interest in criticality safety applications.

Marshall, William (BJ) J.↗

HLRW management during MR reactor decommissioning in NRC 'Kurchatov Institute'

A program of decommissioning of MR research reactor in the Kurchatov institute started in 2008. The decommissioning work presumed a preliminary stage, which included: removal of spent fuel from near reactor storage; removal of spent fuel assemble of metal liquid loop channel from a core; identification, sorting and disposal of radioactive objects from gateway of the reactor; identification, sorting and disposal of radioactive objects from cells of HLRW storage of the Kurchatov institute for radwaste creating form the decommissioning of MR. All these works were performed by a remote controlled means with use of a remote identification methods of high radioactive objects. A distribution of activity along high radiated objects was measured by a collimated radiometer installed on the robot Brokk-90, a gamma image of the object was registered by gamma-visor. Spectrum of gamma radiation was measured by a gamma locator and semiconductor detector system. For identification of a presence of uranium isotopes in the HLRW a technique, based on the registration of characteristic radiation of U, was developed. For fragmentation of high radiated objects was used a cold cutting technique and dust suppression system was applied for reduction of volume activity of aerosols in air. The management of HLRW was performed by remote controlled robots Brokk-180 and Brokk-330. They executed sorting, cutting and parking of high radiated part of contaminated equipment. The use of these techniques allowed to reduce individual and collective doses of personal performed the decommissioning. The average individual dose of the personnel was 1,9 mSv/year in 2011, and the collective dose is estimated by 0,0605 man x Sv/year. Use of the remote control machines enables reducing the number of working personal (20 men) and doses. X-ray spectrometric methods enable determination of a presence of the U in high radiated objects and special cans and separation of them for further spent fuel inspection. The sorting of radwaste enabled shipping of the LLRW and ILRW to special repositories and keeping of the HLRW for decay in the Kurchatov institute repository. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗