Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation and Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Access Accommodation Study

A new mission payload concept for the International Space Station (ISS) called ACCESS (Advanced Cosmic-ray Composition Experiment for Space Station) has undergone a preliminary study which is now complete, and its results are published here. The mission holds the promise for answering many of the outstanding astrophysical questions associated with Galactic cosmic rays and their role in our Galaxy. ACCESS science goals include measurement of the rare ultra-high energy and ultra-heavy components of cosmic radiation which have not been analyzed previously above the Earth's atmosphere. The critical resource made available by the ISS is collection factor (area x exposure time), as much as 10,000 square meters-sr-days for a four-year stay on-orbit. This will allow ACCESS to go beyond balloon-borne detectors and take the science of cosmic-ray observation to the threshold of space. The ACCESS instrument, consisting of a charge module, a transition radiation detector, and a calorimeter, should make valuable measurements of nuclei throughout the periodic table up to 1015 eV. The concept, options, mission plan, and accommodation issues for such an ISS payload are summarized. This includes the carrier, ISS Site, mass, thermal control, power, data and operations. The study demonstrates that the ISS, as a stable science platform at the threshold of space, makes improved cosmic-ray ACCESS possible at the turn of the century.

Wilson, Thomas L.↗

Active Region Extent Assessment with X-rays (AREA-X)

The development of semiconductor sensors for new particle tracking detectors places increasing limits on sensor characteristics such as uniformity, size and shape of inefficient areas and size of active compared to inactive sensor areas. Accurately assessing these relatively subtle effects requires either measurements in particle beams or the modification of samples to be used in dedicated laser test setups. Active Region Extent Assessment with X-rays (AREA-X) has been developed as an alternative method for the fast, efficient and precise study of the active area of a semiconductor sensor. It uses a monochromatic, micro-focused X-ray beam with a 10–20 keV energy range as provided by several synchrotron beam lines and uses the photo current induced in the sensor to measure the depth of the responsive sensor volume. It can be used to study local inhomogeneities or inefficiencies, the overall extent of the active sensor volume and its shape and its localised application, which makes the need to gather statistics over a large area unnecessary, allowing for fast readout, which enables studies of the sensor behaviour at a range of external parameters, e.g. temperature or applied bias voltage. This paper presents the measurement concept and technical setup of the measurement, results from initial measurements as well as capabilities and limitations of the method.

47 OTHER INSTRUMENTATION↗

Progress of Multicolor Single Detector to Detector Array Development for Remote Sensing

Knowledge of the spatial and temporal distribution of atmospheric species such as CO2, O3, H2O, and CH4 is important for understanding the chemistry and physical cycles involving Earth s atmosphere. Although several remote sensing techniques are suitable for such measurements they are considered high cost techniques involving complicated instrumentation. Therefore, simultaneous measurement of atmospheric species using a single remote sensing instrument is significant for minimizing cost, size and complexity. While maintaining the instrument sensitivity and range, quality of multicolor detector, in terms of high quantum efficiency and low noise are vital for these missions. As the first step for developing multicolor focal plan array, the structure of a single element multicolor detector is presented in this paper. The detector consists of three p-n junction layers of Si, GaSb and InAs wafer bonded to cover the spectral range UV to 900 nm, 800 nm to 1.7 m, and 1.5 m to 3.4 m, respectively. Modeling of the absorption coefficient for each material was carried out for optimizing the layers thicknesses for maximum absorption. The resulted quantum efficiency of each layer has been determined except InAs layer. The optical and electrical characterization of each layer structure is reported including dark current and spectral response measurements of Si pin structure and of GaSb and InAs p-n junctions. The effect of the material processing is discussed.

Abedin, M. Nurul↗

KSPEC-a near-infrared cross-dispersed spectrograph

KSPEC (k-band spectrograph) is an infrared spectrograph designed primarily for spectroscopy in the 2.0-2.5 micrometer region. It offers two different optical configurations. The first is a cross-dispersed echelle mode designed to cover the atmospheric windows from 1-2.5 micrometer in one spectral frame of a 256x256 format on a Near Infrared Camera and Multi-Object Spectrometer-3 (NICMOS-3) HgCdTe detector array. This configuration of the spectrograph provides medium spectral resolution (lambda/delta-lambda approximately = 500) for spectral classification work, emission-line detection, and redshift measurements. Alternatively, KSPEC can be equipped with a different spectrograph camera, giving a long-slit, single-order spectrum from 2.05-2.35 micrometer. The instrument uses a second NICMOS-3 infrared detector array for slit viewing, to facilitate the acquisition of optically invisible objects, to document the slit position, and to monitor it during long spectroscopic integrations. KSPEC does not contain any moving components, making it a very reliable, relatively low-cost instrument that is easy to use.

Hodapp, Klaus-Werner↗

The Haleakala Stokes polarimeter

A versatile Stokes polarimeter for solar observations has been developed. Recent improvements to the instrument include a high-resolution echelle spectrometer coupled to the telescope by optical fibers, and 128-element diode array detectors. The on-axis design on the telescope and polarimeter limit instrumental polarization to .0001, and the spectrometer detector combination provides spectral resolving power of 160,000 for any wavelength between 4000 and 11,000 A. This paper describes the Haleakala polarimeter and in particular the spectrometer with its fiber-optic coupling. Examples of Stokes line profiles observed in a sunspot are presented, together with derived vector magnetic field maps.

Mickey, D. L.↗

Axion Dark Matter Experiment: Detailed design and operations

Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66–3.1 μeV mass range with Dine–Fischler–Srednicki–Zhitnisky sensitivity. Therefore, it is the most sensitive axion search experiment to date in this mass range. Here, we discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The EPIC-MOS Particle-Induced Background Spectrum

We have developed a method for constructing a spectrum of the particle-induced instrumental background of the XMM-Newton EPIC MOS detectors that can be used for observations of the diffuse background and extended sources that fill a significant fraction of the instrument field of view. The strength and spectrum of the particle-induced background, that is, the background due to the interaction of particles with the detector and the detector surroundings, is temporally variable as well as spatially variable over individual chips. Our method uses a combination of the filter-wheel-closed data and a database of unexposed-region data to construct a spectrum of the "quiescent" background. We show that, using this method of background subtraction, the differences between independent observations of the same region of "blank sky" are consistent with the statistical uncertainties except when there is clear evidence of solar wind charge exchange emission. We use the blank sky observations to show that contamination by SWCX emission is a strong function of the solar wind proton flux, and that observations through the flanks of the magnetosheath appear to be contaminated only at much higher solar wind fluxes. We have also developed a spectral model of the residual soft proton flares, which allows their effects to be removed to a substantial degree during spectral fitting.

Kuntz, K. D.↗

Quality concerns caused by quality control — deformation of silicon strip detector modules in thermal cycling tests

The ATLAS experiment at the Large Hadron Collider (LHC) is currently preparing to replace its present Inner Detector (ID) with the upgraded, all-silicon Inner Tracker (ITk) for its High-Luminosity upgrade (HL-LHC). The ITk will consist of a central pixel tracker and the outer strip tracker, consisting of about 19,000 strip detector modules. Each strip module is assembled from up to two sensors, and up to five flexes (depending on its geometry) in a series of gluing, wirebonding and quality control steps. During detector operation, modules will be cooled down to temperatures of about -35 °C (corresponding to the temperature of the support structures on which they will be mounted) after being initially assembled and stored at room temperature. In order to ensure compatibility with the detector's operating temperature range, modules are subjected to thermal cycling as part of their quality control process. Ten cycles between -35 °C and +40 °C are performed for each module, with full electrical characterisation tests at each high and low temperature point. As part of an investigation into the stress experienced by modules during cooling, it was observed that modules generally showed a change in module shape before and after thermal cycling. This paper presents a summary of the discovery and understanding of the observed changes, connecting them with excess module stress, as well as the resulting modifications to the module thermal cycling procedure.

47 OTHER INSTRUMENTATION↗

EPCAPE-PT-LANL Measurements: Scanning Mobility Particle Sizer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Scanning Mobility Particle Sizer (TSI), DMA Classifier Model 3082 + CPC Detector Model 3752. Data Notes: The SMPS dataset is limited due to necessary instrument maintenance and subsequent extensive downtime. Data is only available from October 21 to November 8, 2023. Post November 22, 2023, the NanoScan instrument provided coverage for the latter half of the campaign. To ensure consistency, the data was resampled into uniform size bins ranging from 15 nm to 667 nm. This adjustment was required due to changes in size bins and the maximum diameter that occurred after maintenance and repairs. Multiple Charge Correction applied, Nanoparticle Agglomerate Mobility Analysis not applied, and Diffusion Correction applied. Header: - List [15 nm to 667 nm] middle of the size bin in nanometers: Data reports the concentration particles in this size bin per cubic centimeter, dN/dLog(dp). - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement.

54 ENVIRONMENTAL SCIENCES↗

Sensor response and radiation damage effects for 3D pixels in the ATLAS IBL Detector

Pixel sensors in 3D technology equip the outer ends of the staves of the Insertable B Layer (IBL), the innermost layer of the ATLAS Pixel Detector, which was installed before the start of LHC Run 2 in 2015. 3D pixel sensors are expected to exhibit more tolerance to radiation damage and are the technology of choice for the innermost layer in the ATLAS tracker upgrade for the HL-LHC programme. While the LHC has delivered an integrated luminosity of ≃ 235 fb -1 since the start of Run 2, the 3D sensors have received a non-ionising energy deposition corresponding to a fluence of ≃ 8.5 × 10 14 1 MeV neutron-equivalent cm -2 averaged over the sensor area. This paper presents results of measurements of the 3D pixel sensors' response during Run 2 and the first two years of Run 3, with predictions of its evolution until the end of Run 3 in 2025. Data are compared with radiation damage simulations, based on detailed maps of the electric field in the Si substrate, at various fluence levels and bias voltage values. These results illustrate the potential of 3D technology for pixel applications in high-radiation

47 OTHER INSTRUMENTATION↗

MAMA Detector

Work carried out under this grant led to fundamental discoveries and over one hundred publications in the scientific literature. Fundamental developments in instrumentation were made including all the instrumentation on the EUVE satellite, the invention of a whole new type of grazing instrument spectrometer and the development of fundamentally new photon counting detectors including the Wedge and Strip used on EUVE and many other missions and the Time Delay detector used on OREFUS and FUSE. The Wedge and Strip and Time Delay detectors were developed under this grant for less than two million dollars and have been used in numerous missions most recently for the FUSE mission. In addition, a fundamentally new type of diffuse spectrometer has been developed under this grant which has been used in instrumentation on the MMSAT spacecraft and the Lewis spacecraft. Plans are underway to use this instrumentation on several other missions as well.

Bowyer, Stuart↗

The Parameterization of Top-Hat Particle Sensors with Microchannel-Plate-Based Detection Systems and its Application to the Fast Plasma Investigation on NASA's Magnetospheric MultiScale Mission

The most common instrument for low energy plasmas consists of a top-hat electrostatic analyzer geometry coupled with a microchannel-plate (MCP)-based detection system. While the electrostatic optics for such sensors are readily simulated and parameterized during the laboratory calibration process, the detection system is often less well characterized. Furthermore, due to finite resources, for large sensor suites such as the Fast Plasma Investigation (FPI) on NASA's Magnetospheric Multiscale (MMS) mission, calibration data are increasingly sparse. Measurements must be interpolated and extrapolated to understand instrument behavior for untestable operating modes and yet sensor inter-calibration is critical to mission success. To characterize instruments from a minimal set of parameters we have developed the first comprehensive mathematical description of both sensor electrostatic optics and particle detection systems. We include effects of MCP efficiency, gain, scattering, capacitive crosstalk, and charge cloud spreading at the detector output. Our parameterization enables the interpolation and extrapolation of instrument response to all relevant particle energies, detector high voltage settings, and polar angles from a small set of calibration data. We apply this model to the 32 sensor heads in the Dual Electron Sensor (DES) and 32 sensor heads in the Dual Ion Sensor (DIS) instruments on the 4 MMS observatories and use least squares fitting of calibration data to extract all key instrument parameters. Parameters that will evolve in flight, namely MCP gain, will be determined daily through application of this model to specifically tailored in-flight calibration activities, providing a robust characterization of sensor suite performance throughout mission lifetime. Beyond FPI, our model provides a valuable framework for the simulation and evaluation of future detection system designs and can be used to maximize instrument understanding with minimal calibration resources.

Instrument-model↗

Pair Production Detectors for Gamma-ray Astrophysics

Electron-positron pair production is the essential process for high-energyγ-ray astrophysical observations. Following the pioneeringOSO-3counter telescope, the field evolved into use of particle tracking instruments, largely derived from high-energy physics detectors. Although many of the techniques were developed on balloon-borneγ-ray telescopes, the need to escape the high background in the at-mosphere meant that the breakthrough discoveries came from theSAS-2andCOS-Bsatellites. The next major pair production success was EGRET on the Comp-ton Gamma Ray Observatory, which provided the first all-sky map at energies above 100 MeV and found a variety ofγ-ray sources, many of which were vari-able. The current generation of pair production telescopes,AGILEandFermiLAT,have broadened high-energyγ-ray astrophysics with particular emphasis on multi-wavelength and multimessenger studies. A variety of options remain open for future missions based on pair production with improved instrumental performance.

Gamma rays↗

A microchip microcontroller-based transducer controller for non-contact scanning probe microscopy with phase-locked loop, amplitude, and Q control

An inexpensive yet versatile transducer controller for non-contact scanning probe microscopy (SPM) based on a PIC32 microcontroller from Microchip Technology, Inc is described. In addition to feedback control using the amplitude or phase of the signal from the non-contact transducer, the controller includes a phase-locked loop for frequency-shift feedback, as well as fixed-amplitude, quality factor (Q) control, and self-excitation modes. Apart from the input amplifiers, output buffers, and the Q-control circuit, all other functions of the controller are instantiated in software on the microchip, enabling rapid changes in operating parameters if needed. The controller communicates with a host personal computer via a simple serial connection. The controller has been tested with a quartz tuning-fork transducer but can be used with any oscillating non-contact transducer.

47 OTHER INSTRUMENTATION↗

A convergence metric for counting statistics in time-resolved small angle neutron scattering

Here, this work introduces a model-independent, dimensionless metric for predicting optimal measurement duration in time-resolved small-angle neutron scattering using early-time data. Built on a Gaussian process regression framework, the method reconstructs scattering profiles with quantified uncertainty, even from sparse or noisy measurements. Demonstrated on the EQ-SANS instrument at the Spallation Neutron Source, the approach generalizes to general SANS instruments with a two-dimensional detector. A key result is the discovery of a dimensionless convergence metric revealing a universal power-law scaling in profile evolution across soft matter systems. When time is normalized by a system-specific characteristic time t*, the variation in inferred profiles collapses onto a single curve with an exponent between −2 and −1. This trend emerges within the first ten time steps, enabling early prediction of measurement sufficiency. The method supports real-time experimental optimization and is especially valuable for maximizing efficiency in low-flux environments such as compact accelerator-based neutron sources.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

FPGA-based tracking for the CMS Level-1 trigger using the tracklet algorithm

The high instantaneous luminosities expected following the upgrade of the Large Hadron Collider (LHC) to the High-Luminosity LHC (HL-LHC) pose major experimental challenges for the CMS experiment. A central component to allow efficient operation under these conditions is the reconstruction of charged particle trajectories and their inclusion in the hardware based trigger system. There are many challenges involved in achieving this: a large input data rate of about 20–40 Tb/s; processing a new batch of input data every 25 ns, each consisting of about 15,000 precise position measurements and rough transverse momentum measurements of particles (“stubs”); performing the pattern recognition on these stubs to find the trajectories; and producing the list of trajectory parameters within 4 µs. Here, this paper describes a proposed solution to this problem, specifically, it presents a novel approach to pattern recognition and charged particle trajectory reconstruction using an all-FPGA solution. The results of an end-to-end demonstrator system, based on Xilinx Virtex-7 FPGAs, that meets timing and performance requirements are presented along with a further improved, optimized version of the algorithm together with its corresponding expected performance.

47 OTHER INSTRUMENTATION↗

Characterisations of the HinOTORI telescope with a three-color imager at Ali Observatory in Western Tibet

HinOTORI is a new telescope supported by an international collaboration project between China and Japan. It is a 50 centimeter telescope equipped with simultaneous three-color imagers (u',R C , and I C bands). It is located at Ali Observatory at an altitude of 5100m. Thanks to the high altitude and extreme dryness, Ali site is one of the most suitable sites for optical astrometry. HinOTORI telescope aims at detecting optical transients such as the counterparts of gravitational wave (GW) sources, supernovae, gamma-ray bursts (GRB) and so on. This paper describes the site information, design of simultaneous three-color optical layout, system instruments and whole control system. We also report some telescope characterisations for three bands (u'/R C /I C ) respectively, such as Hartmann constant (0.49"/0.56"/0.60"), best focus position (3.922/3.920/3.903 mm), PSF FWHM size (3.755/3.328/3.167pixels), total transmittance and limiting magnitude (15.69/17.57/17.05mag, 10 σ 30 seconds exposure time). With different airmass observation data, the atmospheric extinction coefficients of three bands (0.366/0.061/0.026) were also derived.

47 OTHER INSTRUMENTATION↗