Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Instrumentation Set Points”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method may be of two types: foil and fiber-optic. Four foil gauges (full bridge) are mounted on each of the tank-supporting legs. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. One or more fiber-optic gauges may be used instead of the foil gauges. The resolution of the fiber-optic and foil gauges is approximately the same, but the fiber-optic gauges are immune to EMI (electromagnetic interference), are linear with respect to temperature over their entire dynamic range (as defined by the behavior of the sample), and measure thermally induced deformations as predictable signals. Conversely, long term testing has demonstrated that the foil gauges exhibit an erratic behavior whenever subjected to direct sun radiation (even if protected with a rubberized cover). Henceforth, for deployment in outdoor conditions, fiber-optic gauges are the only option if one is to rely on the system for an extended period of time when a recalibration procedure may not be acceptable. A set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 micro-strain) that occurred during filling and emptying of the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. However, the reliability of the foil gauges over a few hours was not acceptable. Therefore, the foil sensor system is acceptable for use only in controlled environments (complete shade, or indoors).

Figueroa, Jorge↗

Feasibility of Helical Tomotherapy in Stereotactic Body Radiation Therapy for Centrally Located Early Stage Non-Small-Cell Lung Cancer or Lung Metastases

Purpose: To investigate the ability of helical tomotherapy (HT) to spare critical organs immediately adjacent to the tumor target in stereotactic body radiation therapy (SBRT) for centrally located lung lesions. Methods and Materials: HT SBRT plans for 10 patients with centrally located lesions or lesions immediately adjacent to a critical structure were generated. A total of 70 Gy in 10 fractions was prescribed to the planning target volume (PTV) to satisfy a target volume coverage of {>=}95% PTV receiving 70 Gy and an established set of dose constraints for the organs at risk (OARs). Quality assurance (QA) of the HT plans was performed with both ion chamber and film measurements. Results: The PTV coverage criteria was met with 95% of the PTV receiving 70.68 {+-} 0.33 Gy for all cases even though the OARs immediately adjacent to the PTV ranged from 0.38 to 0.85 cm away. The mean lung dose (MLD), and V{sub 20} were 7.15 {+-} 1.44 Gy, and 11.93 {+-} 3.24 % for the total lung, respectively. The dose parameters of MLD, V{sub 5}, V{sub 10}, and V{sub 20} for the contralateral lung were significantly lower than those for the ipsilateral lung (p < 0.05). An average dose fall off from the PTV periphery to the edge of the immediately adjacent OAR was 47.6% over an average distance of 4.87 mm. Comparison of calculated and measured doses with the ion chamber showed an average of 1.85% point dose error, whereas an average mean gamma and the area with a gamma larger than 1 of 0.20 and 0.94% were observed, respectively. Conclusion: HT allows the sparing of critical structures immediately adjacent to the tumor target, thus making SBRT for these centrally located lesions feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Workshop on Advances in NASA-Relevant, Minimally Invasive Instrumentation

The purpose of this meeting is to highlight those advances in instrumentation and methodology that can be applied to the medical problems that will be encountered as the duration of manned space missions is extended. Information on work that is presently being done by NASA as well as other approaches in which NASA is not participating will be exchanged. The NASA-sponsored efforts that will be discussed are part of the overall Space Medicine Program that has been undertaken by NASA to address the medical problems of manned spaceflight. These problems include those that have been observed in the past as well as those which are anticipated as missions become longer, traverse different orbits, or are in any way different. This conference is arranged in order to address the types of instrumentation that might be used in several major medical problem areas. Instrumentation that will help in the cardiovascular, musculoskeletal, and psychological areas, among others will be presented. Interest lies in identifying instrumentation which will help in learning more about ourselves through experiments performed directly on humans. Great emphasis is placed on non-invasive approaches, although every substantial program basic to animal research will be needed in the foreseeable future. Space Medicine is a rather small affair in what is primarily an engineering organization. Space Medicine is conducted throughout NASA by a very small skeleton staff at the headquarters office in Washington and by our various field centers. These centers include the Johnson Space Center in Houston, Texas, the Ames Research Center in Moffett Field, California, the Jet Propulsion Laboratory in Pasadena, California, the Kennedy Space Center in Florida, and the Langley Research Center in Hampton, Virginia. Throughout these various centers, work is conducted in-house by NASA's own staff scientists, physicians, and engineers. In addition, various universities, industries, and other government laboratories perform research that cannot be effectively carried out in-house. At the moment, approximately 50% of the work is performed in-house and 50% is extramural. The area of bioinstrumentation pervades every one of our problem areas. In each, equipment or procedures are being developed that will allow more clinical work to be done in a ground-based or spacecraft setting. Although work of this kind goes on throughout the NASA organization and through its grants and contracts in the community at large, the major thrust of it is concentrated at the Jet Propulsion Laboratory which plays a lead role in this type of research and acts as the lead center in bioinstrumentation for NASA. It is recognized that there is much additional research being pursued in this area which would be potentially valuable to NASA and could, with some stimulation from, be made more applicable to NASA's needs. It is hoped, therefore, that the proceedings of this conference will be used as the basis for developing research strategies to be used as a road map to point the way in which NASA's own sponsored program should proceed over the course of the next three years. Additionally, it is hoped that the conference will highlight additional areas in which NASA should be involved either in-house or through the sponsorship of non-NASA scientists. NASA would also like to get an idea of which areas should be emphasized or perhaps de-emphasized among those that it is currently pursuing. In considering these questions, the discussion should concern itself not so much with whether a particular procedure or piece of equipment would work in a spacecraft, but rather, with whether the procedures that are advocated are at the state-of-the-art or beyond the state-of-the-art and whether they hold promise of giving additional insight into the problems to be confronted as humans venture into space for longer and longer periods of time.

Source record↗

Evaluation of Deep Learning Model Architectures for Point-of-Care Ultrasound Diagnostics

Point-of-care ultrasound imaging is a critical tool for patient triage during trauma for diagnosing injuries and prioritizing limited medical evacuation resources. Specifically, an eFAST exam evaluates if there are free fluids in the chest or abdomen but this is only possible if ultrasound scans can be accurately interpreted, a challenge in the pre-hospital setting. In this effort, we evaluated the use of artificial intelligent eFAST image interpretation models. Widely used deep learning model architectures were evaluated as well as Bayesian models optimized for six different diagnostic models: pneumothorax (i) B- or (ii) M-mode, hemothorax (iii) B- or (iv) M-mode, (v) pelvic or bladder abdominal hemorrhage and (vi) right upper quadrant abdominal hemorrhage. Models were trained using images captured in 27 swine. Using a leave-one-subject-out training approach, the MobileNetV2 and DarkNet53 models surpassed 85% accuracy for each M-mode scan site. The different B-mode models performed worse with accuracies between 68% and 74% except for the pelvic hemorrhage model, which only reached 62% accuracy for all model architectures. These results highlight which eFAST scan sites can be easily automated with image interpretation models, while other scan sites, such as the bladder hemorrhage model, will require more robust model development or data augmentation to improve performance. With these additional improvements, the skill threshold for ultrasound-based triage can be reduced, thus expanding its utility in the pre-hospital setting.

47 OTHER INSTRUMENTATION↗

SU-G-TeP2-14: Universal Function Form for Photon Open Field In-Water Output Ratio

Purpose: In-Water-Output-Ratio (IWOR) plays a significant role in linac-based radiotherapy treatment planning, linking MUs to delivered radiation dose. For an open rectangular field, IWOR depends on both its width and length, and changes rapidly when one of them becomes small. In this study, a universal functional form is proposed to fit the open field IWOR tables in Varian TrueBeam representative datasets for all photon energies. Methods: A novel Generalized Mean formula is first used to estimate the Equivalent Square (ES) for a rectangular field. The formula’s weighting factor and power index are determined by collapsing all data points as much as possible onto a single curve in IWOR vs. ES plot. The result is then fitted with a novel universal function IWOR=1+b*Log(ES/10cm)/(ES/10cm)^c via a least-square procedure to determine the optimal values for parameters b and c. The maximum relative residual error in IWOR over the entire two-dimensional measurement table with field sizes between 3cm and 40cm is used to evaluate the quality of fit for the function. Results: The two-step fitting strategy works very well in determining the optimal parameter values for open field IWOR of each photon energies in the Varian data-set. Relative residual error ≤0.71% is achieved for all photon energies (including Flattening-Filter-Free modes) with field sizes between 3cm and 40cm. The optimal parameter values change smoothly with regular photon beam quality. Conclusion: The universal functional form fits the Varian TrueBeam open field IWOR measurement tables accurately with small relative residual errors for all photon energies. Therefore, it can be an excellent choice to represent IWOR in absolute dose and MU calculations. The functional form can also be used as a QA/commissioning tool to verify the measured data quality and consistency by checking the IWOR data behavior against the function for new photon energies with arbitrary beam quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating Zonal Asymmetries in Stratospheric Ozone Trends From Satellite Limb Observations and a Chemical Transport Model

This study investigates the origin of a zonal asymmetry in stratospheric ozone trends at northern high latitudes, identified in satellite limb observations over the past two decades. We use a merged data set consisting of ozone profiles retrieved at the University of Bremen from SCIAMACHY and OMPS-LP measurements to derive ozone trends. We also use TOMCAT chemical transport model (CTM) simulations, forced by ERA5 reanalyses, to investigate the factors that drive the asymmetry observed in the long-term changes. By studying seasonally and longitudinally resolved observation-based ozone trends, we find, especially during spring, a well-pronounced asymmetry at polar latitudes with values up to +6 % per decade over Greenland and −5 % per decade over western Russia. The control CTM simulation agrees well with these observed trends, whereas sensitivity simulations indicate that chemical mechanisms involved in the production and removal of ozone, or their changes, are unlikely to explain the observed behavior. The decomposition of TOMCAT ozone time series and ERA5 geopotential height into the first two wavenumber components shows a clear correlation between the two variables in the middle stratosphere and demonstrates a weakening and a shift in the wavenumber-1 planetary wave activity over the past two decades. Finally, the analysis of the polar vortex position and strength points to a decadal oscillation with a reversal pattern at the beginning of the century. The same is found in the ozone trend asymmetry. This further stresses the link between changes in the polar vortex position and the identified ozone trend pattern.

Instrumentation↗

Algorithms and Statistical Models for Scientific Discovery in the Petabyte Era

The field of astronomy has arrived at a turning point in terms of size and complexity of both datasets and scientific collaboration. Commensurately, algorithms and statistical models have begun to adapt --- e.g., via the onset of artificial intelligence --- which itself presents new challenges and opportunities for growth. This white paper aims to offer guidance and ideas for how we can evolve our technical and collaborative frameworks to promote efficient algorithmic development and take advantage of opportunities for scientific discovery in the petabyte era. We discuss challenges for discovery in large and complex data sets; challenges and requirements for the next stage of development of statistical methodologies and algorithmic tool sets; how we might change our paradigms of collaboration and education; and the ethical implications of scientists' contributions to widely applicable algorithms and computational modeling. We start with six distinct recommendations that are supported by the commentary following them. This white paper is related to a larger corpus of effort that has taken place within and around the Petabytes to Science Workshops (https://petabytestoscience.github.io/).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Innovative Transponder-Based Interferometric Radar for Vibration Measurements

Ground-based radar interferometry has recently emerged as an innovative technology of remote sensing, able to accurately measure the static or dynamic displacement of several points of a structure. This technique in the last couple of years has been applied to different types of structures, such as bridges, towers and chimneys. This paper presents a prototype system developed by IDS, originally aimed at measuring the structural vibrations of helicopter rotor blades, based on an interferometric technique and constituted by combination of a radar sensor and a series of transponders installed on the target structure. The main advantages of this solution with respect to conventional interferometric radars, are related to the increased spatial resolution of the system, provided by the possibility to discriminate different transponders installed within the same resolution cell of the radar sensor, and to the reduction of the ambient noise (e.g. multi-path) on the radar measurement. The first feature allows the use of the microwave technology even on target areas with limited dimensions, such as industrial facilities, while the second aspect may extend the use of radar interferometric systems to complex scenarios, where multi-reflections are expected due to the presence of natural targets with high reflectivity to the radar signal. In the paper, the system and its major characteristics are first described; subsequently, application to the measurement of ambient vibration response of a lab set-up is summarized. Then the data acquired on a rotating mock-up are reported and analyzed to identify natural frequencies and mode shapes of the investigated structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation and application of the peak scaling method for temperature measurement in the laser heated diamond anvil cell

In this work, a new design for a double-sided high-pressure diamond anvil cell laser heating set-up is described. The prototype is deployed at beamline 12.2.2 of the Advanced Light Source at Lawrence Berkeley National Lab. Our compact design features shortened mechanical lever arms, which results in more stable imaging optics, and thus more user friendly and more reliable temperature measurements based on pyrometry. A modification of the peak scaling method was implemented for pyrometry, including an iterative method to determine the absolute peak temperature, thus allowing for quasi-real time temperature mapping of the actual hotspot within a laser-heated diamond anvil cell without any assumptions on shape, size, and symmetry of the hotspot and without any assumptions to the relationship between fitted temperature and peak temperature. This is important since we show that the relationship between peak temperature and temperature obtained by fitting the Planck function against the thermal emission spectrum averaged over the entire hotspot is not constant but depends on variable fitting parameters (in particular, the size and position of the fitting window). The accuracy of the method is confirmed through measuring melting points of metal wires at ambient pressure. Having absolute temperature maps in real time allows for more differentiated analyses of laser heating experiments. Finally, we present such an example of the pressure variations within a heated hotspot of AgI at a loaded base pressure of 3.8 GPa.

42 ENGINEERING↗

Constraints on iron sulfate and iron oxide mineralogy from ChemCam visible/near-infrared reflectance spectroscopy of Mt. Sharp basal units, Gale Crater, Mars

Relative reflectace point spectra (400–840 nm) were acquired by the Chemistry and Camera (ChemCam) instrument on the Mars Science Laboratory (MSL) rover Curiosity in passive mode (no laser) of drill tailings and broken rock fragments near the rover as it entered the lower reaches of Mt. Sharp and of landforms at distances of 2–8 km. Freshly disturbed surfaces are less subject to the spectral masking effects of dust, and revealed spectral features consistent with the presence of iron oxides and ferric sulfates. Here, we present the first detection on Mars of a ~433 nm absorption band consistent with small abundances of ferric sulfates, corroborated by jarosite detections by the Chemistry and Mineralogy (CheMin) X-ray diffraction instrument in the Mojave, Telegraph Peak, and Confidence Hills drilled samples. The disturbed materials near the Bonanza King region also exhibited strong 433 nm bands and negative near-infrared spectral slopes consistent with jarosite. ChemCam passive spectra of the Confidence Hills and Mojave drill tailings showed features suggestive of the crystalline hematite identified by CheMin analyses. The Windjana drill sample tailings exhibited flat, low relative reflectance spectra, explained by the occurrence of magnetite detected by CheMin. Passive spectra of Bonanza King were similar, suggesting the presence of spectrally dark and neutral minerals such as magnetite. Long-distance spectra of the “Hematite Ridge” feature (3–5 km from the rover) exhibited features consistent with crystalline hematite. The Bagnold dune field north of the Hematite Ridge area exhibited low relative reflectance and near-infrared features indicative of basaltic materials (olivine, pyroxene). Light-toned layers south of Hematite Ridge lacked distinct spectral features in the 400–840 nm region, and may represent portions of nearby clay minerals and sulfates mapped with orbital near-infrared observations. The presence of ferric sulfates such as jarosite in the drill tailings suggests a relatively acidic environment, likely associated with flow of iron-bearing fluids, associated oxidation, and/or hydrothermal leaching of sedimentary rocks. Combined with other remote sensing data sets, mineralogical constraints from ChemCam passive spectra will continue to play an important role in interpreting the mineralogy and composition of materials encountered as Curiosity traverses further south within the basal layers of the Mt. Sharp complex.

58 GEOSCIENCES↗

Using High-Resolution NSRDB Data to Evaluate Cloud Mask Forecast from WRF-Solar EPS

Validating spatiotemporal distributions of cloud forecasts using numerical weather prediction (NWP) models is difficult as this requires high-quality cloud-property at significantly high spatial and temporal resolution over extended periods of time. Observations of cloud properties, such as cloud mask, cloud optical thickness, and cloud type, are vital for assessing the capability of NWP models to forecast various types of clouds. Using the National Solar Radiation Database (NSRDB), this research evaluates ensemble cloud-mask predictions from the WRF-Solar ensemble prediction system (WRF-Solar EPS). From the WRF-Solar EPS, day-ahead solar forecasts for the contiguous United States (CONUS) for 2018 are simulated. Given the NSRDB data is accessible at a resolution of 2 km, we can calculate the cloud fraction across the 9-km grid of WRF-Solar EPS. This allows us to spatially assess the cloud-mask forecasts using two methods against the high-resolution NSRDB: (a) considering all 2-km NSRDB clouds in the forecast domain (EMAll), and (b) using a minimum cloud fraction threshold of 50% to designate a pixel as cloudy (EMP50). The low-resolution cloud masks from WRF-Solar EPS are evaluated directly against the cloud-resolving scale gridded observations from NSRDB using EMAll. With EMP50, we presume that scenes with less than 50% cloud cover from the 2-km NSRDB are clear. Thus, this assessment approach allows for a fair comparison with WRF-Solar EPS resolved to a 9-km grid. A method of point-by-point verification is used to evaluate dichotomous (yes/no) cloud mask predictions against the NSRDB. For each pixel of model extent, cloud frequency and traditional metrics (e.g., probability of detection, false alarm rate, and hit rate, etc.) are computed and compared with satellite-derived data sets. Mismatched cloud frequency (MCF) is computed to measure the present capability of WRF-Solar EPS in representing various types of clouds, which are categorized using three levels of cloud top height (CTH) and cloud optical depth (COD) across entire CONUS. Preliminary results show that the WRF-Solar EPS provides MCF values ranging from 9% to 46%, 16% to 33%, and 8% to 27% for low-level, middle-level, and high-level clouds, respectively, for three CTHs. The model produces MCFs ranging from 27% to 46%, 13% to 34%, and 8% to 19% for thin, medium-thickness, and thick clouds, respectively, for three CODs. The presentation will include a detailed description of the current outcomes as well as potential future extensions. The evaluation approach established in this study is readily extensible to the evaluation of cloud predictions from different ensemble NWP models. In addition, the findings of the suggested evaluation technique aid in identifying model weaknesses and will ultimately lead to advances in WRF-Solar EPS's skill in predicting clouds and solar irradiance.

cloud mask forecast↗

Transit Habitat Government-Reference Conceptual Design Reaction Control System Propulsion Concept Design Data Book

The function of Transit Habitat (TH) Reaction Control System (RCS) propulsion is to provide free-flying spacecraft capabilities and to augment Gateway stack control when docked on Gateway. The requirements of multiple propellant replenishments and extensive life operation have significant impacts on selection of the propulsion system concept and components for the RCS. The intent of this document is to provide insight into the government-reference conceptual design of a propulsion system for TH element. A pressure-fed hypergolic bi-propellant system is the assumed propulsion approach for the RCS. Its architectural concept is being traded within the NASA Moon to Mars architecture. A pressure-regulated system is examined. The propellants under consideration are Monomethyl Hydrazine (MMH) and Mixed Oxides of Nitrogen with 3% Nitric Oxide (MON3). A peer review was conducted to assess the flow schematic design and propulsion component selection, compliant with a set of assumed requirements. Redundant components to satisfy one-fault tolerance for function and two-fault tolerance against catastrophic events are incorporated in the propulsion concept design. Instrumentation laid out on the schematic would be used to gather data to monitor the health of the propulsion system and to support quantity gauging of the propulsion system fluids. Venting propellant ullage gas overboard during the refilling operations poses a significant concern to the external surfaces of the TH. A liquid/gas separator would be required to eliminate, or at least reduce, the amount of liquid propellant expelled in the vent gas mixture. The technology readiness level of the phase separator for the TH must be advanced. Metal diaphragm and non-positive-expulsion PMD propellant tank systems were traded against each other, with the PMD architecture being selected. A blowdown concept is also considered for the TH RCS propulsion. Its fluid schematic is derived from the pressure-regulated schematic with removal of assemblies involving the helium pressurization and ullage venting. Its system wet mass is 10% heavier than the pressure-regulated due to thruster performance loss and larger propellant tanks. There is no firm constraint on the propulsion system mass at this phase of the design. The blowdown concept can offer reduction in component count and operation, that would lead to a more reliable propulsion system. The blowdown concept would also benefit avionics, thermal, power, and structures on the TH. Assessing these benefits will be carried as a future work. Drawbacks of thrust and minimum impulse bit (MIB) variations due to the blowdown operation would be acceptable to Guidance, Navigation, and Control (GNC). Although the blowdown concept has been selected as a current baseline, further evaluation of the concept will be the subject of future work to ensure that the blowdown propulsion operation is appropriate for the HT RCS propulsion. This document also highlights key trade studies and design decisions, including pros and cons of the selected concept. Other appropriate options for components are pointed out for future assessments. Additional background information and documents for further review are referenced in this report.

spacecraft propulsion↗

Optimization of phosphor-based detector design for oblique x-ray incidence in digital breast tomosynthesis

Purpose: In digital breast tomosynthesis (DBT), a volumetric reconstruction of the breast is generated from a limited range of x-ray projections. One trade-off of DBT is resolution loss in the projections due to non-normal (i.e., oblique) x-ray incidence. Although degradation in image quality due to oblique incidence has been studied using empirical data and Monte Carlo simulations, a theoretical treatment has been lacking. The purpose of this work is to extend Swank's calculations of the transfer functions of turbid granular phosphors to oblique incidence. The model is ultimately used as a tool for optimizing the design of DBT detectors. Methods: A quantum-limited system and 20 keV x-rays are considered. Under these assumptions, the modulation transfer function (MTF) and noise power spectra (NPS) are derived using the diffusion approximation to the Boltzmann equation to model optical scatter within the phosphor. This approach is applicable to a nonstructured scintillator such as gadolinium oxysulfide doped with terbium (Gd{sub 2}O{sub 2}S:Tb), which is commonly used in breast imaging and which can reasonably approximate other detector materials. The detective quantum efficiency (DQE) is then determined from the Nishikawa formulation, where it is written as the product of the x-ray quantum detection efficiency, the Swank factor, and the Lubberts fraction. Transfer functions are calculated for both front- and back-screen configurations, which differ by positioning the photocathode at the exit or entrance point of the x-ray beam, respectively. Results: In the front-screen configuration, MTF and DQE are found to have considerable angular dependence, while NPS is shown to vary minimally with projection angle. As expected, the high frequency MTF and DQE are degraded substantially at large angles. By contrast, all transfer functions for the back-screen configuration have the advantage of significantly less angular dependence. Using these models, we investigated the possibility for optimizing the design of DBT detectors. As an example optimization strategy, the phosphor thickness which maximizes the DQE at a fixed frequency is analyzed. This work demonstrates that the optimal phosphor thickness for the front-screen is angularly dependent, shifting to lower thickness at higher angles. Conversely, the back-screen is not optimized by a single thickness but instead attains reasonably high DQE values over a large range of thicknesses. Although the back-screen configuration is not suited for current detectors using a glass substrate, it may prove to be preferred in future detectors using newly proposed plastic thin-film transistor (TFT) substrates. Conclusions: Using the diffusion approximation to the Boltzmann equation to model the spread of light in a scintillator, this paper develops an analytical model of MTF, NPS, and DQE for a phosphor irradiated obliquely. The model is set apart from other studies on oblique incidence in being derived from first principles. This work has applications in the optimization of DBT detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-12A-06: A Comprehensive Parameter Analysis for Low Dose Cone-Beam CT Reconstruction

Purpose: There is always a parameter in compressive sensing based iterative reconstruction (IR) methods low dose cone-beam CT (CBCT), which controls the weight of regularization relative to data fidelity. A clear understanding of the relationship between image quality and parameter values is important. The purpose of this study is to investigate this subject based on experimental data and a representative advanced IR algorithm using Tight-frame (TF) regularization. Methods: Three data sets of a Catphan phantom acquired at low, regular and high dose levels are used. For each tests, 90 projections covering a 200-degree scan range are used for reconstruction. Three different regions-of-interest (ROIs) of different contrasts are used to calculate contrast-to-noise ratios (CNR) for contrast evaluation. A single point structure is used to measure modulation transfer function (MTF) for spatial-resolution evaluation. Finally, we analyze CNRs and MTFs to study the relationship between image quality and parameter selections. Results: It was found that: 1) there is no universal optimal parameter. The optimal parameter value depends on specific task and dose level. 2) There is a clear trade-off between CNR and resolution. The parameter for the best CNR is always smaller than that for the best resolution. 3) Optimal parameters are also dose-specific. Data acquired under a high dose protocol require less regularization, yielding smaller optimal parameter values. 4) Comparing with conventional FDK images, TF-based CBCT images are better under a certain optimally selected parameters. The advantages are more obvious for low dose data. Conclusion: We have investigated the relationship between image quality and parameter values in the TF-based IR algorithm. Preliminary results indicate optimal parameters are specific to both the task types and dose levels, providing guidance for selecting parameters in advanced IR algorithms. This work is supported in part by NIH (1R01CA154747-01)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bremsstrahlung x-ray generation for high optical depth radiography applications on the National Ignition Facility [Bremsstrahlung x-ray generation for opacity radiography applications on the National Ignition Facility]

Here, we have tested a set of x-ray sources for use as probes of highly attenuating, laser-driven experiments on the National Ignition Facility (NIF). Unlike traditional x-ray sources that optimize for a characteristic atomic transition (often the n = 2 → n = 1 transition in ionized, He-like atoms), the design presented here maximizes the total photon flux by optimizing for intense, broadband Bremsstrahlung radiation. Three experiments were performed with identical targets, including a uranium x-ray source foil and a tungsten substrate with a narrow (25 μm wide) collimating slit to produce a quasi-1D x-ray source. Two experiments were performed using 12 beams from the NIF laser, each delivering approximately 46 kJ of laser energy but with different laser spatial profiles. This pair yielded similar temporal x-ray emission profiles, spatial resolution, and inferred hot electron temperature. A third experiment with only 6 beams delivering approximately 25 kJ produced a lower hot electron temperature and significantly lower x-ray flux, as well as poorer spatial resolution. The data suggest that laser pointing jitter may have affected the location and intensity of the emitting plasma, producing an emission volume that was not well centered behind the collimating slit and lower intensity than designed. However, the 12-beam design permits x-ray radiography through highly attenuating samples, where lower energy line-emission x-ray sources would be nearly completely attenuated.

47 OTHER INSTRUMENTATION↗

The use of a diode matrix in commissioning activities for electron energies {>=}9 MeV: A feasibility study

The contribution of a commercially available diode matrix (MapCHECK trade mark sign , provided by Sun Nuclear, Melbourne, FL) for the commissioning procedures of the voxel based Monte Carlo (VMC++) algorithm for electron beams of MasterPlan treatment planning system was investigated. The attention is mainly focused on the calculation in homogeneous and heterogeneous phantoms. With this aim, following a data set similar to that proposed by Electron Collaborative Working Group (ECWG), the dose profiles and two-dimensional (2D) dose distributions measured by the diode matrix were compared with the calculated ones using the gamma analysis method with acceptance criteria for the dose difference and the distance to agreement equal to 4% and 4 mm, respectively. The average and standard deviation of the percentage of points satisfying the constraint {gamma}{<=}1 are 98.3{+-}4.1% and 99.3{+-}1.7% for the 9 and 12 MeV electron beam, respectively, showing that the accuracy of MasterPlan electron beam algorithm is good for simple two-dimensional geometries as well as for more complicated three-dimensional ones. The results are in agreement with those reported in literature by Cygler et al. [''Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning,'' Med. Phys. 31, 142-153 (2004)]. In addition, the authors have also analyzed the response of the 2D array in terms of dose profiles at different depths, comparing the results with those obtained in water phantom using an electron diode. The results show that in the low gradient regions there were no deviations larger than the criteria of acceptability set by Van Dyk et al. [''Commissioning and quality assurance of treatment planning computers,'' Int. J. Radiat. Oncol. Biol. Phys. 26, 261-273 (1993)]; in the high gradient region, the maximum deviations are less than 2 mm with most of the values less than 1 mm. The present article shows that MapCHECK trade mark sign can play a useful role in the commissioning of electron algorithms of treatment planning systems in the evaluation of the 2D dose distributions in homogeneous and heterogeneous phantoms. In fact, it provides accurate results with the merit of expediting the commissioning process by using measuring device that requires minimal setup time and data processing time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation shielding analysis of the concrete hutch of a long beamline of the Advanced Photon Source Upgrade project

The radiation shielding analysis of the external concrete enclosure of a feature long beamline of the Advanced Photon Source Upgrade project is described in this work. The beamline has 2 undulators that can operate in two different configurations and the source terms are estimated for the worst configuration using the SRW code in the OASYS package as well as the STAC8 code. The shielding analysis is carried out using the STAC8 code, and for the case of pink beam, with the FLUKA code also. Effective dose rates on contact with the outside surface of the concrete walls for pink, reflected full spectrum and monochromatic beams are calculated. For the monochromatic beams, 2 sets of discrete bandwidths (BW) from the Double Crystal Monochromator (DCM) and the full reflectance of the Double Multilayer Monochromator (DMM) are used. Further, due to the size of the direct beam and the energy domain of interest in the direct and scattered fields, the importance of the equivalent dose to the lens of the eye is discussed with respect to the shielding calculations of such facilities. The dose rates outside the concrete hutch in the lateral directions calculated using STAC8 is about 50% higher than the FLUKA results for the case of pink beam but may be considered as a reasonable agreement due to the differences in the calculational methodologies. Those dose rates in the lateral and forward directions are higher for the pink beam to allow full occupancy from the radiation protection point of view. For the full spectrum after 3 reflections, the effective dose rates are less than 0.5 Sv/h in the lateral direction but is higher in the forward region below about 22° with respect to the beam direction. For the DCM beams, except for the scenario with one mirror and 0.1%BW, all dose rates are less than 0.5 Sv/h outside the concrete hutch in the lateral directions. Here, the higher harmonics are what contributes to the dose outside the shield and the bandwidths assumed to derive the photon flux thus becomes important. The dose rates with the DMM are generally lower compared to the 0.1% BW DCM beam but are higher than the results obtained with XOP calculated bandwidths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature Measurements in the Magnetic Measurement Facility

Several key LCLS undulator parameter values depend strongly on temperature primarily because of the permanent magnet material the undulators are constructed with. The undulators will be tuned to have specific parameter values in the Magnetic Measurement Facility (MMF). Consequently, it is necessary for the temperature of the MMF to remain fairly constant. Requirements on undulator temperature have been established. When in use, the undulator temperature will be in the range 20.0 {+-} 0.2 C. In the MMF, the undulator tuning will be done at 20.0 {+-} 0.1 C. For special studies, the MMF temperature set point can be changed to a value between 18 C and 23 C with stability of {+-}0.1 C. In order to ensure that the MMF temperature requirements are met, the MMF must have a system to measure temperatures. The accuracy of the MMF temperature measurement system must be better than the {+-}0.1 C undulator tuning temperature tolerance, and is taken to be {+-}0.01 C. The temperature measurement system for the MMF is under construction. It is similar to a prototype system we built two years ago in the Sector 10 alignment lab at SLAC. At that time, our goal was to measure the lab temperature to {+-}0.1 C. The system has worked well for two years and has maintained its accuracy. For the MMF system, we propose better sensors and a more extensive calibration program to achieve the factor of 10 increase in accuracy. In this note we describe the measurement system under construction. We motivate our choice of system components and give an overview of the system. Most of the software for the system has been written and will be discussed. We discuss error sources in temperature measurements and show how these errors have been dealt with. The calibration system is described in detail. All the LCLS undulators must be tuned in the Magnetic Measurement Facility at the same temperature to within {+-}0.1 C. In order to ensure this, we are building a system to measure the temperature of the undulators to {+-}0.01 C. This note describes the temperature measurement system under construction.

43 PARTICLE ACCELERATORS↗