Mechanical and Thermophysical Properties of 3D-Printed SiC before and after Neutron Irradiation – FY21

This report presents the mechanical and thermophysical properties of 3D-printed SiC before and after neutron irradiation that have been evaluated to assess the fuel matrix material for the Transformational Challenge Reactor (TCR). The TCR fuel form consists of an additively-manufactured silicon carbide (SiC) matrix and uranium nitride tristructural isotropic (UN TRISO) fuel particles, which is manufactured through a newly developed processing route combining binderjet 3D printing, TRISO fuel particle loading, and chemical vapor infiltration (CVI). Because the fuel matrix is a primary component of the TCR core and its response to mechanical and thermal loads during operation is one of the most influential factors on the integrity of TCR core, testing and evaluation have focused on producing mechanical and thermophysical properties data for the binderjet/CVI SiC. Baseline mechanical and thermophysical properties were measured from the disk specimens printed for different and sizes orientations, which included equibiaxial flexural failure strength, elastic constants, thermal diffusivity and conductivity, density, and the coefficient of thermal expansion. Flexural failure strength datasets showed similar Weibull distributions regardless of sample variants including different orientations. The mean failure strengths of the 3D-printed SiC variants were in the range of 280–310 MPa, which are slightly lower than that of the chemical vapor deposition (CVD) SiC. Thermophysical test results showed that specific heat and thermal expansion are not sensitive to the build direction of SiC samples, while thermal conductivity is highly dependent on the build direction and can be correlated to the anisotropic character of the 3D-printed SiC. Neutron irradiation tests were carried out on the 3D-printed 6-mm diameter SiC disk specimens. Irradiation was carried to 2.3 dpa over a temperature range of 360–880°C. No significant degradation in strength was observed in SiC after irradiations in various conditions and with different orientations. Anisotropy that had been observed in the thermal conductivity of 3D-printed SiC prior to irradiation vanished after irradiation as the irradiation defect thermal resistivity accumulated in the material. Electron microscopy of the microstructure after neutron irradiation showed distinct defect morphologies in the heterogenous material, but no evidence for irradiation-induced cracking or degradation in the microstructure was observed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Processing of SOFC Anodes for Enhanced Intermediate Temperature Catalytic Activity at High Fuel Utilization (Final Report)

The overall objective was to infiltrate anodes with nanoparticle catalysts so that anode catalytic performance can be improved as anode operation temperature is reduced from 800°C to intermediate temperatures of 700°C and 600°C and as anode fuel utilization is increased. The addition of nickel nanoparticle catalysts into the anode improves performance by providing additional triple phase boundaries (TPBs), increasing the density of electrochemical reaction sites. To achieve this goal, both liquid phase and vapor phase methods for depositing nickel nanoparticles in the anode active layer, the region of the anode near the electrolyte where the electrochemical reaction occurs. It is imperative that nanoparticles are stable against coarsening during long-term operation, so the mechanisms and kinetics of nanoparticle stability during cell operation will be investigated. Finally, priority is given to processes that are scalable and easily transferable to industry, leveraging existing Ni-YSZ cermet anode technology. Utilizing nickel nanoparticles at different temperatures has different considerations that will be addressed. At the upper end of the intermediate temperature range (800°C), it is important that performance improvement is maintained over long periods by mitigating the instability of nanoparticles. At the middle of the temperature range (700°C), it is important that performance improvement is maintained at high fuel utilizations. At the lower end of the temperature range (600°C), where the performance of cells is poor due to increased resistances, it is important to improve anode performance by significantly increasing the electrochemical reaction site density, while nanoparticle durability is less of an issue. Finally, the objective was to explore mixed ionic and electronic (MIEC) nanoparticle catalysts like GDC to see if 2-phase boundaries can be created to increase the electrochemical reactions at the anode.

20 FOSSIL-FUELED POWER PLANTS↗

Electrochemically Stable High Energy Density Lithium-Sulfur Batteries

Lithium-Sulfur batteries (LSB) have emerged as one of the strong contenders for high energy density rechargeable batteries in the Li-ion battery domain. The LSB system is considered as the most promising to achieve the next milestone in energy density of 500 Wh/kg. However, the LSB system is plagued with problems of polysulfide formation which are soluble in the organic electrolyte leading to loss in capacity and eventual cell failure. The problem is further compounded by dendrite formation on the Li anode during electrochemical cycling leading to puncturing of the separator causing eventual short-circuiting of the cell and consequent heat generation resulting in major safety hazards of flammability of the organic liquid electrolyte and impending explosion. This chapter describes various approaches developed to combat both cathode and anode issues. These involve synthesis and characterization of complex framework materials (CFMs) for confining the polysulfides and sulfur in the LSB cathodes. The CFMs include a CFM host and a coating applied to the CFM host, which includes one or more form of an electronic conductor, a lithium-ion conductor and a functional electrocatalyst for electrocatalytically converting the soluble polysulfides to Li 2 S. Further, sulfur is infiltrated into the CFM host creating a sulfur-carbon linkage serving as effective anchors for trapping the ensuing polysulfides. The systems have been tested in coin cells and pouch cells with metallic Li anodes under lean electrolyte conditions of 3-4 μl/mg of electrolyte (E) to sulfur (S) ratios showing promise and feasibility. New emergent dendrite-free alloys have also been identified to test against pure Li and CFM cathodes in coin cell and pouch cell configurations under lean electrolyte conditions. Results of these studies are described and discussed with thoughts on future directions.

25 ENERGY STORAGE↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY2021 Status Report on the Computing Systems for the Yucca Mountain Project TSPA-LA Models and Testing of Selected Process Models

Sandia National Laboratories continued evaluation of the total system performance assessment (TSPA) for License Application (LA) computing systems for the previously considered Yucca Mountain Project (YMP). This was done to maintain the operational readiness of the computing infrastructure (computer hardware and software) and knowledge capability for total system performance assessment) type analysis, as directed by the National Nuclear Security Administration (NNSA), DOE 2010. The FY21 task included continued operation of the cluster; maintenance of the TSPA-LA models (with GoldSim 9.60.300); continued assessment of the status of the Infiltration Model; (a process model that feeds the TSP -LA) and preliminary assessments of the Unsaturated Zone Flow Model and the Saturated Zone Flow and Transport Model Abstraction (process models that feed the TSPA-LA). The 2014 cluster and supporting software systems are currently fully operational to support TSPA-LA type analyses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Performance SOFCs with a Superior Stability for Reliable and Durable Power Systems

Next generation of fuel cells, electrolyzers, and batteries requires higher power, faster kinetics, and larger energy density, which necessitate the use of compositionally complex oxides to achieve multifunctionalities and activity. These compositionally complex oxides may change their phases and structures during an electrochemical process – a so-called “electrochemically driven phase transformation”. The origin for such a phase change has remained obscure. More importantly, there is a need to develop high performance solid oxide fuel cells with an enhanced stability. In this work, the La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3 (LSCF) cathode surface is modified by infiltration of Pr 6 O 11 and the power density at 0.8V and 750 °C is improved by 21%. In addition, by replacing the traditional barrier layer Gd 0.2 Ce 0.8 O 1.9 with mixed conducting Pr 0.1 Gd 0.1 Ce 0.8 O 1.9 , the power density increases by 38%. The different mechanism of promotions was investigated by electrochemical impedance spectroscopy. The ohmic resistance is dramatically reduced by applying the PGCO interlayer, and the distribution of relaxation time was used to analyze the mechanism for which the polarization resistance was decreased attributing to the mixed conduction nature in PrO x . An increase of power density at 0.8 V of 0.358 W/cm 2 (71%) is achieved with the implementation of both surface modification and buffer layer engineering. An experimental study and a theoretical analysis were then carried out on phase evolution in praseodymium nickelates. Nickelate-based electrodes show up to 60× greater phase transformation during operation when compared to thermally annealed ones. Theoretical analysis suggests that the presence of a reduced oxygen partial pressure at the interface between the oxygen electrode and the electrolyte is the origin for the phase change in an oxygen electrode. Guided by the theory, an addition of the electronic conduction in the interface layer leads to the significant suppression of phase change, while improving cell performance and performance stability. When an oxygen electrode is under polarization, the oxygen partial pressure at the interface between the oxygen electrode and the electrolyte is lower than that of incoming oxidant. Under a high polarization, the environment at the aforementioned interface may lead to phase transformation of the oxygen electrode. The local oxygen partial pressure is determined by the transport properties at the interfaces. An addition of the electronic conduction in the interface layer, for instance using (Pr,Gd)-doped ceria to replace Gd-doped ceria, results in improved cell performance and performance stability, while the phase transformation is significantly suppressed. This work provides a fundamental understanding of the origin for phase transformation in oxygen electrodes during operation and use this knowledge to develop a high-performance electrode that exhibits improved performance stability.

30 DIRECT ENERGY CONVERSION↗

The Energy in Modular (EMOD) Buildings Method: A Guide to Energy-Efficient Design for Industrialized Construction of Modular Buildings

Industrialized construction has immense potential to address the growing need globally to build and upgrade the building stock to be affordable, energy-efficient, and resilient. It can also help achieve the United States' goal of a 50% reduction in U.S. greenhouse gas (GHG) emissions by 2030. Despite this potential, and the ever-increasing push for electrification and decarbonization of households in the United States, industrialized construction has not yet been leveraged specifically to help address these challenges and accelerate the pathway to meet these goals. The National Renewable Energy Laboratory (NREL) aims to claim this missed opportunity by focusing on delivering affordable, grid-efficient net-zero energy (NZE) modular buildings for underserved communities to ensure an equitable transition to the future of clean energy, accelerate decarbonization of the built environment, and support the development of a high-productivity construction and energy efficiency workforce. The Energy in Modular (EMOD) method is our approach to designing, producing, and delivering affordable, net-zero energy, low-carbon, and healthier buildings at scale. The following energy efficiency strategies are part of the scope of this guide: envelope thermal control, envelope infiltration control, mechanical, electrical, and plumbing systems, smart controls, and solar plus storage. We draw synergies between design for manufacturing and assembly, process optimization, retrofit technologies, and digitization. Our goal is to influence the improvement and production of buildings to increase performance, enhance energy efficiency, and reduce GHG emissions. This guide documents the research and development efforts initiated by a set of design objectives to "modularize" a set of energy efficiency and low-carbon strategies into a housing unit while preserving and enhancing energy efficiency benefits and decarbonization pathways. This guide is intended to serve as a framework for housing developers, housing agencies, architects, energy experts, and process engineers or factory operator personnel who are critical to today's modular builder teams. This guide focuses on specific energy efficiency strategies, decarbonization pathways, and associated processes as part of NREL's research efforts. Stakeholders may substitute other means, methods, and technologies for the ones evaluated in this study.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

Annual energy savings of up to $\$ 4$ to $\$ 5$ billion could be achieved nationwide through basic insulation and heating system retrofits of existing homes. However, current utility energy efficiency programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and online advertising that lack specificity about home-specific retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments (HEAs) that are inconvenient to homeowners, expensive, and of variable accuracy. We developed computational algorithms that automatically analyze communicating thermostat (CT) heating data that could be used to increase the customer uptake of insulation and air sealing energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. The algorithms are based on an extended second-order grey-box model that characterizes a building’s thermal response using lumped elements, coupled with an empirical model of infiltration that accounts for both wind and stack effects. The basic parameters of the model correspond to actual physical parameters of the home, i.e., the home’s overall R-value of and the building envelope ACH50. Unlike the conventional approach, which estimates model parameters based on the best fit to the observed time-dependent room temperature, our approach derives correlations between the daily heating system runtime and temperature difference (indoor-outdoor) that are more robust to data quality issues in real-world applications. We also used HEA data for algorithm development and validation. With the help of our utility partners, Eversource and National Grid, we obtained data sets for hundreds of Massachusetts homes. For each home, these data sets included three sets of information anonymized by the utility: (1) CT data (HVAC runtime, room temperature, and, for some vendors, outdoor temperature and wind speed) collected by the CT vendor (one of three) over a heating season, (2) HEA report performed by the HEA vendor (same vendor for all homes), (3) Monthly utility gas bills coincident with the CT data (3 to 24 per home, depending on availability). For some homes, we also obtained blower-door test results. Initially, we applied the algorithms developed to homes with a single CT and then extended them to homes with two CTs by using an equivalent home approach. Finally, we developed algorithms for prediction of energy savings and a methodology of comparing our predictions with those generated by HEAs. The main technical results indicate that we can reliably identify homes with insulation and/or air sealing retrofit opportunities and provide accurate savings predictions. Our hypothesis is that the algorithms could be applied to utility energy efficiency programs to identify homes that could realize significant energy savings from insulation and/or air sealing retrofits. This information could then be used to reach out to those homes with highly customized outreach, thereby delivering increased program energy savings and cost-effectiveness. This would: Significantly increase the uptake rate of on-site HEAs, and Significantly increase the fraction of HEAs resulting in ECM implementation. To test these hypotheses, we designed and conducted a randomized controlled trial (RCT). The RCT results suggest that personal messaging leads to a two- to five-fold increase in the HEA uptake rate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mach Conference, 2022.

There has been considerable interest in chemical vapor infiltration (CVI) manufactured silicon carbide fiber and silicon carbide matrix (SiC/SiC) composite tubes due to their superior mechanical properties. The SiC/SiC tubes are known to remain stable even after prolonged exposure to radiation. However, there are many variables in the manufacturing of SiC/SiC composite tubes such as elastic constants of constituent SiC fiber and SiC matrix, braiding angle, porosity, and others whose values vary over a range. The intention is to identify the distribution of elastic constants of SiC/SiC tubes which would help model the performance of the novel cladding material. To do so, a sensitivity analysis will be carried out to determine the dominant variables that influence the elastic constants of SiC/SiC tubes. A chosen number of combinations of dominant variables will be sampled through the Latin hypercube sampling (LHS) method. The elastic constants of composite tube namely Young's moduli in the circumferential and longitudinal direction, Poisson's ratio, and shear modulus will be calculated at sampled points through finite element (FE) analysis. A polynomial response surface (PRS) will be built for each of the elastic constants to be used as a surrogate to FE analysis. Once the predictive accuracy of PRS is verified at the validation set of data points, the PRS will be invoked 105 times in Monte Carlo simulations (MCS). The uncertainty can be quantified by calculating the coefficient of variation (CV) based on MCS-generated data which will be presented at the conference.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Large-Scale Additive Manufacturing of Silicon Carbide with Process Monitoring

This report summarizes new capabilities in additive manufacturing (AM) of large-scale silicon carbide (SiC) components under the Advanced Materials and Manufacturing Technologies (AMMT) program. SiC is a promising material that is being considered for many advanced reactor designs due to its high temperature strength, radiation tolerance, minimal neutron absorption, and oxidation resistance [1-8]. One of the primary limitations to using SiC as an in-core structural material is the inability to fabricate large SiC components with complex geometries. While under the former Transformational Challenge Reactor (TCR) program, ceramic AM systems at the Oak Ridge National Laboratory (ORNL) were limited in the quantity and overall size achievable for producing ceramic AM components. To address this, ORNL has improved its infrastructure for binder jet and chemical vapor infiltration (CVI) processes with cutting-edge equipment coming online in a newly renovated laboratory space capable of producing larger components and higher throughput without compromise on part size. This report details the laboratory renovation progress, focusing specifically on the DesktopMetal (formerly ExOne) X25Pro binder jet, a large scale CVI furnace, and the added functionality of a software tool called Peregrine for quality assurance and control purposes.

36 MATERIALS SCIENCE↗

Understanding FLiNaK Salt Intrusion Behavior on Nuclear-Grade Graphite via Neutron Tomography

Graphite is an essential material as a neutron moderator in molten salt reactors (MSRs). To understand the impact of salt on the graphite structure to develop structural materials for MSRs, molten salt intrusion behavior on nuclear-grade graphite was studied. The graphite samples, IG-110 and PCEA, were tested for infiltration with LiF-NaF-KF (FLiNaK) at 750°C, 5 bar for 12 h, and, after the intrusion experiment, the graphite was analyzed by neutron imaging. The graphite and Li from FLiNaK showed great contrast in the neutron attenuation coefficient. Thus, the salt behavior in the graphite structure has been visualized for the first time without damaging the sample. The 3D image of the graphite was reconstructed after a neutron computed tomography scan, and the average salt coverage distribution of the XY surface in different depths was obtained from the reconstructed 3D images.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Identification of Distribution of Elastic Constants of SiC/SiC Braided Tubes

There has been considerable interest in chemical vapor infiltration (CVI) manufactured silicon carbide fiber and silicon carbide matrix (SiCf/SiCm) composite tubes due to their superior mechanical properties. There are many parameters in the manufacturing of SiCf/SiCm composite tubes such as elastic constants of constituent SiC fiber and SiC matrix, braiding angle, porosity, and others whose values vary over a range. A sensitivity analysis will be carried out to determine the dominant parameters among the abovementioned ones. We intend to determine the variability in elastic constants of SiCf/SiCm composite tubes considering the variability in dominant parameters. A chosen number of combinations of dominant variables will be sampled through Latin hypercube sampling (LHS) method. The elastic constants of composite tube namely Young's moduli in circumferential and longitudinal direction, Poisson's ratio and shear modulus will be calculated at sampled points through finite element (FE) analysis. A polynomial response surface (PRS) will be built for each of the elastic constants to be used a surrogate to FE analysis. once the predictive accuracy of PRS is verified at the validation set of data points, the PRS will be invoked 105 times in Monte Carlo simulations (MCS). The variability can be calculated based on MCS-generated data which will be presented at the conference.

42 ENGINEERING↗

High-Entropy Ceramic Coatings: Transformative New Materials for Environmentally-Compatible Thin-Film Insulators against High-T Molten Salts

An emerging new class of promising materials, High-Entropy Ceramics (HECs) or Compositionally-Complex Ceramics (CCCs), have been successfully fabricated in the last three years. This project evaluates HECs/CCCs in the concentrated solar power (CSP) context. In this project, we have identified a couple of simple, and key descriptors governing thermal conductivity in HECs. Size disorder among the cations was found to have a strong influence on the thermal conductivity across multiple systems and throughout a vast compositional space. Since identifying this, we have optimized previous compositions to achieve low thermal conductivities of $k$~$1-1.4Wm{-1}K{-1}$. We have further reduced our selection of promising compositions based on project guidelines and applied a theory that can potentially predict reactivity with molten salts to identify a small set of HECs that are suitable for further molten salt heat transfer media (HTM) stability testing. Many compositions reveal poor resistance to molten chloride salt after being exposed for 24 h compared to the reference structural alloy, Haynes 230. However, after 100 h, a few HECs/CCCs show strong parabolic rate constant effects and provide greater resistance to chloride salt compared to Haynes 230 alloy, which shows more linear kinetics. Postmortem characterization of the microstructure reveals the parabolic rate constant originates from a dense reaction layer form at the interface. This feature is absent in Haynes 230, which only shows grain boundary infiltration. The HECs/CCCs were also put in contact with the metal alloy under Ar for 800 h at 800°C and show negligible interaction. Lastly, parabolic rate constant HECs/CCCs also have low thermal conductivity $(<2 Wm^{-1} K^{-1})$ at 800°C. These specimens satisfy all project requirements and demonstrate their promising application in next-generation CSP.

14 SOLAR ENERGY↗

Pilot Study for Multifamily Building Ventilation and Indoor Air Quality

Weatherization Program Notice (WPN) 17-7 issued by the US Department of Energy (DOE) Weatherization Assistance Program (WAP) requires that buildings have ventilation in accordance with ASHRAE Standard 62.2-2016 (entitled Ventilation and Indoor Air Quality in Residential Buildings) in dwelling units weatherized under the program. The 2016 version of the standard expanded its scope of application to include all multifamily dwelling units. This has resulted in concerns for buildings where installing ventilation in individual units is costly or otherwise logistically difficult. Also, excessive ventilation rates could significantly increase energy costs, and may cause indoor air quality issues within the buildings. One deficiency that is noted is that the standard does not provide a credit for existing infiltration in multifamily buildings that reduces the required mechanical ventilation levels. This report details findings from a field study investigating envelope air-tightness, inter-unit connectivity, and indoor air quality in centrally ventilated high-rise multifamily buildings with central ventilation systems serving individual units in the state of New York. As allowed under WPN 17-7, the State of New York has a variance in the application of ASHRAE Standard 62.2-2016 in select types of multifamily buildings to provide time to determine how best to implement the standard. The purpose of this pilot study is to characterize the impact that weatherization and feasible ventilation improvements have on the indoor air quality of large, multifamily buildings with centrally ventilated apartments, as currently performed under WAP in the State of New York under their variance request (i.e., to implement ASHRAE Standard 62.2-2016 “to the greatest extent possible” in this type of multifamily building). A major goal is to determine if these practices improve or at least “do no harm” to the indoor air quality of the weatherized multifamily buildings and to the occupants themselves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A radioisotope - enabled reactive transport model for deep vadose zone carbon

In mountainous regions, which constitute the principle source of recharge to major rivers and regional aquifers, infiltration occurs through fractured, partially saturated, weathered bedrock that acts as a boundary layer between saturated aquifers and surface soil. Commonly this deep vadose zone (DVZ) is many meters thick, and yet its role in regulating the generation, retention and mobility of reactive solutes, including nutrients, contaminants and weathering products, is largely unknown. In particular, many of the key reactions that drive the formation of the weathered DVZ and the quality of water moving through it are redox processes, regulated by the availability of organic carbon and oxygen below the soil layer. The role of the DVZ is thus also poorly constrained in the context of carbon stocks and mobility, particularly in lithologies that are naturally high in organic carbon, such as shales. The overarching hypothesis of this study is that upland regions developed in geologic settings with abundant petrogenic carbon store and actively cycle carbon in the weathered DVZ below the soil and above the water table at rates that are significant and currently unconstrained. In order to quantify this cycling, the current study combines novel instrumentation techniques allowing new direct sampling of DVZ systems with advanced numerical reactive transport simulations of carbon transport and transformation. Critically, these simulations will explicitly treat the three isotopes of carbon (the abundant 12C, the stable rare 13C and the radioactive 14C) in a unified framework, thus clearly parsing between the contributions of modern surface derived carbon and lithologic carbon sources in integrated measurements of fluid and gas phase fluxes. This novel model capability will be applied to test the role of DVZ carbon cycling as a regulator of water quality and geological weathering in two complementary field sites both located in organic carbon rich shale lithologies. The first is the Eel River Critical Zone Observatory (ERCZO) in Mendocino County, California, and the second is the Lawrence Berkeley National Laboratory Watershed Function Scientific Focus Area (SFA) in the East River watershed, near Crested Butte, Colorado. At the ERCZO, a novel vadose zone monitoring system has been installed in a 20 m thick, partially saturated, weathered shale hillslope, and preliminary data already indicate substantial CO2 flux generated many meters below the soil surface. At the SFA field site, an instrumented hillslope transect indicates a more complex multi-dimensional fluid and solute transport regime, which will serve as a key test of the calibrated models. Collectively, this project will advance understanding of the cycling of carbon belowground and in relation to transport pathways across the poorly constrained DVZ characteristic of primary water recharge areas. The key product of this work will be enhanced isotope simulation capabilities that are robust and publicly available for application across a broad diversity of systems.

58 GEOSCIENCES↗

Extending the Air and Moisture Leakage Calculator to add Residential Buildings and Additional Commercial Buildings

The DOE Windows and Building Envelope Research and Development Roadmap for Emerging Technologies shows that in 2010, infiltration was responsible for 4 quads of space conditioning primary energy use in the residential and commercial sectors. The relative contribution of air leakage in building heating and cooling load is increasing with improvement in the thermal resistance of building envelopes. Advanced air barrier technologies and construction practices have been developed to reduce air leakage in buildings. However, limited information on the impact of air barrier technologies on energy consumption and the durability of buildings has hindered their adoption. In the past Oak Ridge National Laboratory (ORNL), the National Institute of Standards and Technology (NIST), Air Barrier Association of America (ABBA), and U.S.-China Clean Energy Research Center for Building Energy Efficiency (CERC-BEE) collaborated to develop an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in air tightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations given that air leakage through the building envelope can have a significant impact on moisture transfer and associated impacts. In this study, the calculator is expanded further by adding data for two additional commercial buildings (strip mall and primary school) and a residential building. The team investigated the impact of airtightness on energy consumption and moisture transfer of the added buildings. The study includes the analysis of air tightness in 52 major cities in the U.S. and 5 cities in Canada.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Predictive Engineering of Interfaces and Cathodes for High-Performance All Solid-State Lithium-Sulfur Batteries

The primary goal of this project is to leverage data-driven methods and machine learning strategies to develop accurate multi-physics models for all-solid-state Li-S battery (ASLSB) materials that can capture electrochemical and transport phenomena over atomic to mesoscopic length/timescales. These models will be rigorously validated by synthesis and advanced characterization experiments. The team will leverage the predictive power of these models, alongside synthesis/characterization experiments and battery fabrication to address longstanding issues at the electrode/electrolyte interfaces in ASLSBs. The project’s proposed technology involves the following: (1) halide-doped solid sulfide electrolytes that can concurrently provide high Li + ion conductivity and suppress dendrite growth; (2) novel mesoporous cathode composed of super-P and carbon nanotubes co-infiltrated with sulfur and sulfide electrolyte, which hold potential to allow high sulfur loading and optimal ion/electron pathways; and (3) functionalization of sulfide electrolyte with ionic liquids to improve physical contact and minimize impedance at the cathode/electrolyte interface. Successful development of proposed predictive models (at multiple scales) will bridge this knowledge gap and will advance fundamental understanding of reaction chemistry, kinetics, charge transfer, and dendrite growth at electrified SSIs. This will enable predictive design of effective strategies to mitigate interfacial problems in ASSLSBs, including poor interfacial contact, interfacial impedance to Li + ion transport, and poor electron/ion conduction within cathodes. Ultimately, the fundamental knowledge gained will lead to development of high-performance ASSLSBs.

25 ENERGY STORAGE↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗