Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Imaging a moving lung tumor with megavoltage cone beam computed tomography

Purpose: Respiratory motion may affect the accuracy of image guidance of radiation treatment of lung cancer. A cone beam computed tomography (CBCT) image spans several breathing cycles, resulting in a blurred object with a theoretical size equal to the sum of tumor size and breathing motion. However, several factors may affect this theoretical relationship. The objective of this study was to analyze the effect of tumor motion on megavoltage (MV)-CBCT images, by comparing target sizes on simulation and pretreatment images of a large cohort of lung cancer patients. Methods: Ninety-three MV-CBCT images from 17 patients were analyzed. Internal target volumes were contoured on each MV-CBCT dataset [internal target volume (ITV{sub CB})]. Their extent in each dimension was compared to that of two volumes contoured on simulation 4-dimensional computed tomography (4D-CT) images: the combination of the tumor contours of each phase of the 4D-CT (ITV{sub 4D}) and the volume contoured on the average CT calculated from the 4D-CT phases (ITV{sub ave}). Tumor size and breathing amplitude were assessed by contouring the tumor on each CBCT raw projection where it could be unambiguously identified. The effect of breathing amplitude on the quality of the MV-CBCT image reconstruction was analyzed. Results: The mean differences between the sizes of ITV{sub CB} and ITV{sub 4D} were −1.6 ± 3.3 mm (p < 0.001), −2.4 ± 3.1 mm (p < 0.001), and −7.2 ± 5.3 mm (p < 0.001) in the anterior/posterior (AP), left/right (LR), and superior/inferior (SI) directions, respectively, showing that MV-CBCT underestimates the full target size. The corresponding mean differences between ITV{sub CB} and ITV{sub ave} were 0.3 ± 2.6 mm (p = 0.307), 0.0 ± 2.4 mm (p = 0.86), and −4.0 ± 4.3 mm (p < 0.001), indicating that the average CT image is more representative of what is visible on MV-CBCT in the AP and LR directions. In the SI directions, differences between ITV{sub CB} and ITV{sub ave} could be separated into two groups based on tumor motion: −3.2 ± 3.2 mm for tumor motion less than 15 mm and −10.9 ± 6.3 mm for tumor motion greater than 15 mm. Deviations of measured target extents from their theoretical values derived from tumor size and motion were correlated with motion amplitude similarly for both MV-CBCT and average CT images, suggesting that the two images were subject to similar motion artifacts for motion less than 15 mm. Conclusions: MV-CBCT images are affected by tumor motion and tend to under-represent the full target volume. For tumor motion up to 15 mm, the volume contoured on average CT is comparable to that contoured on the MV-CBCT. Therefore, the average CT should be used in image registration for localization purposes, and the standard 5 mm PTV margin seems adequate. For tumor motion greater than 15 mm, an additional setup margin may need to be used to account for the increased uncertainty in tumor localization.

60 APPLIED LIFE SCIENCES↗

JPEG 2000 Encoding with Perceptual Distortion Control

An alternative approach has been devised for encoding image data in compliance with JPEG 2000, the most recent still-image data-compression standard of the Joint Photographic Experts Group. Heretofore, JPEG 2000 encoding has been implemented by several related schemes classified as rate-based distortion-minimization encoding. In each of these schemes, the end user specifies a desired bit rate and the encoding algorithm strives to attain that rate while minimizing a mean squared error (MSE). While rate-based distortion minimization is appropriate for transmitting data over a limited-bandwidth channel, it is not the best approach for applications in which the perceptual quality of reconstructed images is a major consideration. A better approach for such applications is the present alternative one, denoted perceptual distortion control, in which the encoding algorithm strives to compress data to the lowest bit rate that yields at least a specified level of perceptual image quality. Some additional background information on JPEG 2000 is prerequisite to a meaningful summary of JPEG encoding with perceptual distortion control. The JPEG 2000 encoding process includes two subprocesses known as tier-1 and tier-2 coding. In order to minimize the MSE for the desired bit rate, a rate-distortion- optimization subprocess is introduced between the tier-1 and tier-2 subprocesses. In tier-1 coding, each coding block is independently bit-plane coded from the most-significant-bit (MSB) plane to the least-significant-bit (LSB) plane, using three coding passes (except for the MSB plane, which is coded using only one "clean up" coding pass). For M bit planes, this subprocess involves a total number of (3M - 2) coding passes. An embedded bit stream is then generated for each coding block. Information on the reduction in distortion and the increase in the bit rate associated with each coding pass is collected. This information is then used in a rate-control procedure to determine the contribution of each coding block to the output compressed bit stream.

Watson, Andrew B.↗

Femtosecond Diffractive Imaging with a Soft-X-Ray Free-Electron Laser

Theory predicts that with an ultrashort and extremely bright coherent X-ray pulse, a single diffraction pattern may be recorded from a large macromolecule, a virus, or a cell before the sample explodes and turns into a plasma. Here we report the first experimental demonstration of this principle using the FLASH soft X-ray free-electron laser. An intense 25 fs, 4 x 10{sup 13} W/cm{sup 2} pulse, containing 10{sup 12} photons at 32 nm wavelength, produced a coherent diffraction pattern from a nano-structured non-periodic object, before destroying it at 60,000 K. A novel X-ray camera assured single photon detection sensitivity by filtering out parasitic scattering and plasma radiation. The reconstructed image, obtained directly from the coherent pattern by phase retrieval through oversampling, shows no measurable damage, and extends to diffraction-limited resolution. A three-dimensional data set may be assembled from such images when copies of a reproducible sample are exposed to the beam one by one.

Other,PHYS↗

Multispectral guided fluorescence diffuse optical tomography using upconverting nanoparticles

We report on improved image detectability for fluorescence diffuse optical tomography using upconverting nanoparticles doped with rare-earth elements. Core-shell NaYF{sub 4}:Yb{sup 3+}/Er{sup 3+}@NaYF{sub 4} upconverting nanoparticles were synthesized through a stoichiometric method. The Yb{sup 3+}/Er{sup 3+} sensitizer-activator pair yielded two anti-Stokes shifted fluorescence emission bands at 540 nm and 660 nm, here used to a priori estimate the fluorescence source depth with sub-millimeter precision. A spatially varying regularization incorporated the a priori fluorescence source depth estimation into the tomography reconstruction scheme. Tissue phantom experiments showed both an improved resolution and contrast in the reconstructed images as compared to not using any a priori information.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Soft x-ray holographic microscopy

We present a new x-ray microscopy technique based on Fourier transform holography (FTH), where the sample is separate from the optics part of the setup. The sample can be shifted with respect to the holography optics, thus large-scale or randomly distributed objects become accessible. As this extends FTH into a true microscopy technique, we call it x-ray holographic microscopy (XHM). FTH allows nanoscale imaging without the need for nanometer-size beams. Simple Fourier transform yields an unambiguous image reconstruction. We demonstrate XHM by studying the magnetic domain evolution of a Co/Pt multilayer film as function of locally varied iron overlayer thickness.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Technology Review of Nondestructive Methods for Examination of Water Intrusion Areas on Hanford’s Double-Shell Waste Tanks

Under a contract with CH2M Hill Hanford Group, Inc., PNNL has performed a review of the NDE technology and methods for examination of the concrete dome structure of Hanford’s double-shell tanks. The objective was to provide a matrix of methodologies that could be evaluated based on applicability, ease of deployment, and results that could provide information that could be used in the ongoing structural analysis of the tank dome. PNNL performed a technology evaluation with the objective of providing a critical literature review for all applicable technologies based on constraints provided by CH2M HILL. These constraints were not mandatory, but were desired. These constraints included performing the evaluation without removing any soil from the top of the tank, or if necessary, requesting that the hole diameter needed to gain access to evaluate the top of the tank structure to be no greater than approximately 12-in. in diameter. PNNL did not address the details of statistical sampling requirements as they depend on an unspecified risk tolerance. PNNL considered these during the technology evaluation and have reported the results in the remainder of this document. Many of the basic approaches to concrete inspection that were reviewed in previous efforts are still in use. These include electromagnetic, acoustic, radiographic, etc. The primary improvements in these tools have focused on providing quantitative image reconstruction, thus providing inspectors and analysts with three-dimensional data sets that allow for operator visualization of relevant abnormalities and analytical integration into structural performance models. Available instruments, such as radar used for bridge deck inspections, rely on post-processing algorithms and do not provide real-time visualization. Commercially available equipment only provides qualitative indications of relative concrete damage. It cannot be used as direct input for structural analysis to assess fitness for use and if necessary to de-rate critical components. There are currently no tools that automatically convert the NDE data to formats compatible with structural analysis programs. While radiographic techniques still provide significant advantages in spatial resolution, non-ionizing techniques are still preferred. Radar imagining in the 1–5 GHz has become the most useful. Unfortunately the algorithms and underlying assumptions used in these reconstructions are proprietary, and it is not possible to assess the quality and limitations of the analytical methods used to generate the derived structural data. The hypothesis that water intrusion may contribute to potential rebar corrosion of the tank domes provided the primary guidance in reviewing and evaluating available NDE technologies. Of primary concern is the need to employ technologies that provide the best opportunity for visualizing the rebar and providing quantitative data that can be integrated into structural analysis efforts to better understand and quantify the structural capacity of the domes. The conclusion is that an imaging system capable of locating and quantifying the distribution and conditions of the cement, aggregate, and rebar will provide the most valuable baseline upon which to build a case for the integrity of the structure. If successful, such a system would fulfill the need to incorporate valuable data into current structural load capacity analysis.

54 ENVIRONMENTAL SCIENCES↗

Microwave Imaging on Metal Objects

This final report for the project discusses the attempts to model, using different methods, microwave image reconstruction. Maximum Entropy Method was not successful. Attempts to use Singular Value Decomposition (SVD) got some good results after initial failure. SVD is based upon a theory of linear algebra, to the effect that any M X N Matrix A whose number of rows M is greater than or equal to its number of columns, N can be written as the product of an M X N column-orthogonal matrix U, an N X N diagonal Matrix, W, with m positive or zero elements (the singular values) and the transposition of an N X N orthogonal matrix V. In microwave imaging, the scattered fields can be expressed by the induced current distribution. The SVD method required more contiguous computer memory than was available. Work was also done on the Conjugate Gradient Method (CGM), which didn't work well when tried earlier. It was found that separation of the imaginary part and the real part during calculation may work. This work was considered incomplete as of the end of the grant period.

Tolliver, C. L.↗

Image Fusion of Preprocedural CTA with Real-time Fluoroscopy to Guide Proper Hepatic Artery Catheterization During Transarterial Chemoembolization of Hepatocellular Carcinoma: A Feasibility Study

To assess feasibility of proper hepatic artery catheterization using a 3D model obtained from preprocedural computed tomographic angiography (CTA), fused with real-time fluoroscopy, during transarterial chemoembolization of hepatocellular carcinoma. Twenty consecutive cirrhotic patients with hepatocellular carcinoma undergoing transarterial chemoembolization were prospectively enrolled onto the study. The early arterial phase axial images of the preprocedural CTA were postprocessed on an independent workstation connected to the angiographic system (Innova 4100; GE Healthcare, Milwaukee, WI), obtaining a 3D volume rendering image (VR) that included abdominal aorta, splanchnic arteries, and first and second lumbar vertebrae. The VR image was manually registered to the real-time X-ray fluoroscopy, with the lumbar spine used as the reference. The VR image was then used as guidance to selectively catheterize the proper hepatic artery. The procedure was considered successful when performed with no need for intraarterial contrast injections or angiographic acquisitions. The procedure was successful in 19 (95 %) of 20 patients. In one patient, celiac trunk angiography was required for the presence of a significant ostial stenosis that was underestimated at computed tomography. Time for image reconstruction and registration was <10 min in all cases. The use of preprocedural CTA model with fluoroscopy enables confident and direct catheterization of the proper hepatic artery with no need for preliminary celiac trunk angiography, thus reducing radiation exposure and contrast media administration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-135: Tumor Displacement-Based Binning for Respiratory-Gated Time-Independent 5DCT Treatment Planning

Purpose: A published 5DCT breathing motion model enables image reconstruction at any user-selected breathing phase, defined by the model as a specific amplitude (v) and rate (f). Generation of reconstructed phase-specific CT scans will be required for time-independent radiation dose distribution simulations. This work answers the question: how many amplitude and rate bins are required to describe the tumor motion with a specific spatial resolution? Methods: 19 lung-cancer patients with 21 tumors were scanned using a free-breathing 5DCT protocol, employing an abdominally positioned pneumatic-bellows breathing surrogate and yielding voxel-specific motion model parameters α and β corresponding to motion as a function of amplitude and rate, respectively. Tumor GTVs were contoured on the first (reference) of 25 successive free-breathing fast helical CT image sets. The tumor displacements were binned into widths of 1mm to 5mm in 1mm steps and the total required number of bins recorded. The simulation evaluated the number of bins needed to encompass 100% of the breathing-amplitude and between the 5th and 95th percentile amplitudes to exclude breathing outliers. Results: The mean respiration-induced tumor motion was 9.90mm ± 7.86mm with a maximum of 25mm. The number of bins required was a strong function of the spatial resolution and varied widely between patients. For example, for 2mm bins, between 1–13 amplitude bins and 1–9 rate bins were required to encompass 100% of the breathing amplitude, while 1–6 amplitude bins and 1–3 rate bins were required to encompass 90% of the breathing amplitude. Conclusion: The strong relationship between number of bins and spatial resolution as well as the large variation between patients implies that time-independent radiation dose distribution simulations should be conducted using patient-specific data and that the breathing conditions will have to be carefully considered. This work will lead to the assessment of the dosimetric impact of binning resolution. This study is supported by Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Measurement strategy for rectangular electrical capacitance tomography sensor

To investigate the influence of the measurement strategy for the rectangular electrical capacitance tomography (ECT) sensor, a Finite Element Method (FEM) is utilized to create the model for simulation. The simulation was carried out using COMSOL Multiphysics(trade mark, serif) and Matlab(trade mark, serif). The length-width ratio of the rectangular sensing area is 5. Twelve electrodes are evenly arranged surrounding the pipe. The covering ratio of the electrodes is 90%. The capacitances between different electrode pairs are calculated for a bar distribution. The air of the relative permittivity 1.0 and the material of the permittivity 3.0 are used for the calibration. The relative permittivity of the second phase is 3.0. The noise free and noise data are used for the image reconstruction using the Linear Back Projection (LBP). The measurement strategies with 1-, 2- and 4- electrode excitation are compared using the correlation coefficient. Preliminary results show that the measurement strategy with 2-electrode excitation outperforms other measurement strategies with 1- or 4-electrode excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of refractive index mismatch in optical CT imaging of polymer gel dosimeters

Purpose: Proposing an image reconstruction technique, algebraic reconstruction technique-refraction correction (ART-rc). The proposed method takes care of refractive index mismatches present in gel dosimeter scanner at the boundary, and also corrects for the interior ray refraction. Polymer gel dosimeters with high dose regions have higher refractive index and optical density compared to the background medium, these changes in refractive index at high dose results in interior ray bending. Methods: The inclusion of the effects of refraction is an important step in reconstruction of optical density in gel dosimeters. The proposed ray tracing algorithm models the interior multiple refraction at the inhomogeneities. Jacob’s ray tracing algorithm has been modified to calculate the pathlengths of the ray that traverses through the higher dose regions. The algorithm computes the length of the ray in each pixel along its path and is used as the weight matrix. Algebraic reconstruction technique and pixel based reconstruction algorithms are used for solving the reconstruction problem. The proposed method is tested with numerical phantoms for various noise levels. The experimental dosimetric results are also presented. Results: The results show that the proposed scheme ART-rc is able to reconstruct optical density inside the dosimeter better than the results obtained using filtered backprojection and conventional algebraic reconstruction approaches. The quantitative improvement using ART-rc is evaluated using gamma-index. The refraction errors due to regions of different refractive indices are discussed. The effects of modeling of interior refraction in the dose region are presented. Conclusions: The errors propagated due to multiple refraction effects have been modeled and the improvements in reconstruction using proposed model is presented. The refractive index of the dosimeter has a mismatch with the surrounding medium (for dry air or water scanning). The algorithm reconstructs the dose profiles by estimating refractive indices of multiple inhomogeneities having different refractive indices and optical densities embedded in the dosimeter. This is achieved by tracking the path of the ray that traverses through the dosimeter. Extensive simulation studies have been carried out and results are found to be matching that of experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First look at neutron emission shape characteristics of ignition hotspots at the National Ignition Facility (invited)

The nuclear imaging system has been capturing neutron images of inertial confinement fusion (ICF) driven implosions for over a decade at the National Ignition Facility. This imaging system has evolved from one to three nearly orthogonal lines-of-sight, allowing for the study of three-dimensional shape characteristics of ignition shots. Limited-view tomography algorithms help visualize the burning hotspot in 3D and assess neutron source geometry using Legendre mode parameters. With its neutron, gamma-ray, and x-ray image reconstruction capabilities, NIS has provided critical insight into mechanisms that have limited implosion performance, such as fill tube diameter for ignition-type targets. This comprehensive diagnostic suite opens a window into the shape characteristics of ignition shots and how symmetry affects ICF implosion performance. In more recent ignition shots, neutron yields have visibly increased. Analyzing the shape and size of the reconstructed neutron source has shown an expansion of the burn volume, which is indicative of more efficient alpha heating during the implosion process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-I-11: A New Cone-Beam CT System for Bedside Head Imaging

Purpose: To design and develop a new mobile cone-beam CT (CBCT) system for head imaging with good soft-tissue visibility, to be used bedside in ICU and neurosurgery department to monitor treatment and operation outcome in brain patients. Methods: The imaging chain consists of a 30cmx25cm amorphous silicon flat panel detector and a pulsed, stationary anode monoblock x-ray source of 100kVp at a maximal tube current of 10mA. The detector and source are supported on motorized mechanisms to provide detector lateral shift and source angular tilt, enabling a centered digital radiographic imaging mode and half-fan CBCT, while maximizing the use of the x-ray field and keep the source to detector distance short. A focused linear anti-scatter grid is mounted on the detector, and commercial software with scatter and other corrective algorithms is used for data processing and image reconstruction. The gantry rotates around a horizontal axis, and is able to adjust its height for different patient table positions. Cables are routed through a custom protective sleeve over a large bore with an in-plane twister band, facilitating single 360-degree rotation without a slip-ring at a speed up to 5 seconds per rotation. A UPS provides about 10 minutes of operation off the battery when unplugged. The gantry is on locked casters, whose brake is control by two push handles on both sides for easy reposition. The entire system is designed to have a light weight and a compact size for excellent maneuverability. Results: System design is complete and main imaging components are tested. Initial results will be presented and discussed later in the presentation. Conclusion: A new mobile CBCT system for head imaging is being developed. With its compact size, a large bore, and quality design, it is expected to be a useful imaging tool for bedside uses. The work is supported by a grant from Chinese Academy of Sciences.

60 APPLIED LIFE SCIENCES↗

Structure of the mite-transmitted Blackcurrant reversion nepovirus using electron cryo-microscopy

Blackcurrant reversion nepovirus (BRV; genus Nepovirus) has a single-stranded, bipartite RNA genome surrounded by 60 copies of a single capsid protein (CP). BRV is the most important mite-transmitted viral pathogen of the Ribes species. It is the causal agent of blackcurrant reversion disease. We determined the structure of BRV to 1.7 nm resolution using electron cryo- microscopy (cryoEM) and image reconstruction. The reconstruction reveals a pseudo T = 3 viral capsid similar to that of tobacco ringspot virus (TRSV). We modelled the BRV capsid protein to that of TRSV and fitted it into the cryoEM reconstruction. The fit indicated that the extended C-terminus of BRV-CP is located on the capsid surface and the N-terminus on the interior. We generated peptide antibodies to two putatively exposed C-terminal sequences and these reacted with the virus. Hence homology modelling may be useful for defining epitopes for antibody generation for diagnostic testing of BRV in commercial crops.

60 APPLIED LIFE SCIENCES↗

Physics-guided dual implicit neural representations for source separation

Significant challenges exist in efficient data analysis of most advanced experimental and observational techniques because the collected signals often include unwanted contributions, such as background and signal distortions, that can obscure the physically relevant information of interest. To address this, we have developed a self-supervised machine-learning approach for source separation using a dual implicit neural representation framework that jointly trains two neural networks: one for approximating distortions of the physical signal of interest and the other for learning the effective background contribution. Our method learns directly from the raw data by minimizing a reconstruction-based loss function without requiring labeled data or pre-defined dictionaries. We demonstrate the effectiveness of our framework by considering a challenging case study involving large-scale simulated, as well as experimental, momentum-energy-dependent inelastic neutron scattering data in a four-dimensional parameter space, characterized by heterogeneous background contributions and unknown distortions to the target signal. The method is found to successfully separate physically meaningful signals from a complex or structured background even when the signal characteristics vary across all four dimensions of the parameter space. An analytical approach that informs the choice of the regularization parameter is presented. Our method offers a versatile framework for addressing source separation problems across diverse domains, ranging from superimposed signals in astronomical measurements to structural features in biomedical image reconstructions.

47 OTHER INSTRUMENTATION↗

Radiology and Enterprise Medical Imaging Extensions (REMIX)

Radiology and Enterprise Medical Imaging Extensions (REMIX) is a platform originally designed to both support the medical imaging-driven clinical and clinical research operational needs of Department of Radiology of The Ohio State University Wexner Medical Center. REMIX accommodates the storage and handling of “big imaging data,” as needed for large multi-disciplinary cancer-focused programs. The evolving REMIX platform contains an array of integrated tools/software packages for the following: (1) server and storage management; (2) image reconstruction; (3) digital pathology; (4) de-identification; (5) business intelligence; (6) texture analysis; and (7) artificial intelligence. These capabilities, along with documentation and guidance, explaining how to interact with a commercial system (e.g., PACS, EHR, commercial database) that currently exists in clinical environments, are to be made freely available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The potential for intensity interferometry with {gamma}-ray telescope arrays

Intensity interferometry exploits a quantum optical effect in order to measure objects with extremely small angular scales. The first experiment to use this technique was the Narrabri intensity interferometer, which was successfully used in the 1970s to measure 32 stellar diameters at optical wavelengths; some as small as 0.4 milli-arcseconds. The advantage of this technique, in comparison with Michelson interferometers, is that it requires only relatively crude, but large, light collectors equipped with fast (nanosecond) photon detectors. Ground-based {gamma}-ray telescope arrays have similar specifications, and a number of these observatories are now operating worldwide, with more extensive installations planned for the future. These future instruments (CTA, AGIS, completion 2015) with 30-90 telescopes will provide 400-4000 different baselines that range in length between 50 m and a kilometre. Intensity interferometry with such arrays of telescopes attains 50 {mu}-arcsecond resolution for a limiting m{sub v}{approx}8.5. Phase information can be extracted from the interferometric measurement with phase closure, allowing image reconstruction. This technique opens the possibility of a wide range of studies amongst others, probing the stellar surface activity and the dynamic AU scale circumstellar environment of stars in various crucial evolutionary stages. Here we focuse on the astrophysical potential of an intensity interferometer utilising planned new {gamma}-ray instrumentation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of an X-ray Computed Tomography System for Non-Invasive Imaging of Industrial Materials

X-ray computed tomography is a powerful non-invasive imaging technique for viewing an object's inner structures in two-dimensional cross-section images without the need to physically section it. The invention of CT techniques revolutionised the field of medical diagnostic imaging because it provided more detailed and useful information than any previous non-invasive imaging techniques. The method is increasingly being used in industry, aerospace, geosciences and archaeology. This paper describes the development of an X-ray computed tomography system for imaging of industrial materials. The theoretical aspects of CT scanner, the system configurations and the adopted algorithm for image reconstruction are discussed. The penetrating rays from a 160 kV industrial X-ray machine were used to investigate structures that manifest in a manufactured component or product. Some results were presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗