Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION EXCHANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Enhanced prediction of Cs removal by CST from Hanford tank waste with K accountability

Abstract The treatment of Hanford tank waste is one of the most challenging environmental cleanup activities to date. To expedite the processing of liquid waste stored in underground tanks in Washington State it is necessary to remove the significant dose contributor, 137 Cs. Crystalline silicotitanate ion exchanger is currently used to remove 137 Cs from the aqueous phase of Hanford tank wastes in preparation for vitrification at the Waste Treatment and Immobilization Plant (WTP). Improving the understanding of potassium impacts on ion exchange behavior of Cs will help in the operation of a critical component of one of the most complex treatment processes in the world today. Optimization of this process can result in significant cost savings and less waste production. Toward this effort, a series of batch contact tests varied in potassium concentration were conducted to look at the impact of potassium concentration on Cs distribution. Experimental distribution ratios ( K d ) were compared to the distribution ratios predicted using the ZAM model. A significant underprediction of Cs capacity in the presence of potassium was seen with the existing model. A revision of the equilibrium constants was determined and provided a statistically better fit for determining the Cs K d values in tank waste matrices.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fire Safety Tests for Cesium-Loaded Spherical Resorcinol Formaldehyde Resin: Data Summary Report

A draft safety evaluation of the scenario for spherical resorcinol formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping. To resolve this question, the fire properties of the SRF resin were measured by Southwest Research Institute (SwRI) through a subcontract managed by Pacific Northwest National Laboratory (PNNL). The results of initial fire safety tests on the SRF resin were documented in a previous report (WTP-RPT-218). The present report summarizes the results of additional tests performed by SwRI on the cesium-loaded SRF resin. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. The as-received SwRI report is attached to this report in the Appendix A. Where applicable, the precision and bias of each test method, as given by each American Society for Testing and Materials (ASTM) standard procedure, are included and compared with the SwRI test results of the cesium-loaded SRF resin.

Fire Safety↗

Modified Isotherm Modeling to Predict Cs Exchange with Crystalline Silicotitanate in Tank Waste Simulants

The U.S. Department of Energy is working to expedite processing of Hanford tank waste supernate at the Hanford Waste Treatment and Immobilization Plant. To support this goal, Washington River Protection Solutions is designing a Tank Side Cesium Removal (TSCR) system for suspended solids and cesium (Cs/ 137 Cs) removal from Hanford tank waste supernate. The ion exchange media selected for Cs removal at TSCR is crystalline silicotitanate (CST) that is manufactured in a nearly spherical form by Honeywell UOP LLC (UOP; Des Plaines, IL) as product IONSIV® R9140-B (Na form). The Zheng Anthony Miller (ZAM) isotherm model (Zheng et al. 1997) is a multicomponent ion exchange model used to predict the exchange of Group I metals onto CST. The ZAM isotherm has historically been used to predict Cs distribution values from Hanford and Savannah River Site (SRS) tank waste simulants. Figure S.1 summarizes model predictions from the ZAM isotherm that indicate poor prediction of Cs distribution values for simple and complex simulants with the engineered form of CST, IONSIV® R9140-B, and IONSIV® R9120-B where the solid line indicates a perfect fit by the model. The dotted lines indicate ±20% error. Batch contact testing with Hanford tank waste complex and simple simulants was used in conjunction with SRS simulants to experimentally determine Cs distribution values using a modification to the original isotherm model. The experimentally determined maximum Cs capacity for IONSIV® R9140-B CST in both the simple and complex matrices was found to be 0.53±0.3 mmoles Cs/g of CST. This value is not drastically different from the maximum Cs capacity of 0.58 mmoles Cs/g TAM-5 reported by Zheng et al. (1997). However, it is important to note that TAM-5 (commercially IONSIV® IE-910) is a powder. Hamm et al. (2002) determined that a dilution factor was needed to account for the Zr(OH)2 binder in the engineered form of CST. Hamm et al. determined that a dilution factor of 0.68 was appropriate to account for binder contribution and correct overprediction of Cs exchange on the engineered form of CST in ZAM calculations. This reduced the total capacity from 0.58 mmol/g with TAM-5 to 0.39 mmol/g for the engineered form of CST (Hamm et al. 2002). Despite substituting the experimentally determined maximum Cs capacity of 0.55 mmoles Cs/g for the literature-reported capacity of 0.39 mmoles Cs/g, it was determined that additional modifications to the model’s equilibrium rate constants were necessary in refining the isotherm model. The modified model overpredicted K+ uptake by the CST when compared to digested CST results described by Campbell et al. (2019). The modified model was further revised to omit three of the five K+ exchange equilibrium reactions described by ZAM to reduce the additional K+ loading seen by the model. Figure S.2 summarizes the revised model isotherm predictions plotted against measured Kd values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Anion exchange membranes based on (3-acrylamidopropyl) trimethylammonium chloride (APTA) and phenyl Acrylate: Impact of crosslinker and crosslinker content on physiochemical properties and transport behavior of acetate and formate

CO 2 reduction cells are innovative devices that convert CO 2 into valuable chemicals, such as formate (OFm - ) and acetate (OAc - ), at the cathode. One of the key challenges in these devices is the development of ion exchange membranes that enable the transport of charge carriers between electrodes while minimizing the transfer of CO 2 reduction products. This study focuses on the preparation and characterization of crosslinked anion exchange membranes (AEMs) made of phenyl acrylate (PA) and (3-acrylamidopropyl) trimethylammonium chloride (APTA), crosslinked with either poly(ethylene glycol) diacrylate (PEGDA) or N,N’-methylenebisacrylamide (MBAA). Here, the membranes are characterized to understand their physiochemical properties and corresponding transport behavior through characterization of water volume fraction, mechanical properties, ionic conductivity, ion exchange capacity, water contact angle, glass transition temperature as well as their permeability and solubility to formate and acetate. MBAA crosslinked membranes exhibit higher Young’s modulus and lower strain at break compared to PEGDA-crosslinked membranes, which is attributed to their shorter chain length. Within a series of membranes of varied comonomer content, for either PEGDA or MBAA as crosslinker, permeabilities generally follow free volume theory (increasing permeability with increasing water content where water content increases with decreasing crosslinker content). Interestingly, for membranes with different crosslinkers but analogous water volume fraction significant differences (∼2 orders of magnitude) in permeability are observed which we attribute to differences in chain mobility as characterized through the glass transition temperature.

25 ENERGY STORAGE↗

Catalysis by framework zinc in silica-based molecular sieves

Microporous and mesoporous zincosilicates (e.g., CIT-6, VPI-8, Zn-MFI, and Zn-MCM-41) synthesized in the presence of alkali cations contain two broad types of Zn sites: one that is a dication analog of the monocation ion-exchangeable Al-site in aluminosilicates, while the other resembles isolated Zn sites on amorphous silica. The ratio of these sites varies, depending on the synthesis conditions of the zincosilicate. Post-synthetic strategies based on ion-exchange can alter the site distribution towards either population. Furthermore, post-synthetic introduction of isolated Zn sites of the latter type is possible for materials possessing silanol nests. Both types of sites behave as Lewis acid centers in probe-molecule IR spectroscopy, but have very different catalytic properties. Due to the unusually high adsorption energies of Lewis bases on such materials, Lewis acid catalysis is difficult at low temperatures and in solvents bearing Lewis basic functionality. However, at high temperatures, in hydrocarbon solvents, CIT-6 (Zn-beta) is able to selectively catalyze the Lewis-acid-catalyzed Diels–Alder cycloaddition–dehydration reactions of ethylene with methyl 5-(methoxymethyl)furan-2-carboxylate, a furan that can be derived quantitatively by partial oxidation of biomass-based 5-hydroxymethylfurfural. Additionally, zinc in silica-based molecular sieves is shown here to enable chemistries previously not accessible with framework Sn-, Ti- and Zr-based Lewis acid sites, e.g., the direct production of dimethyl terephthalate by Diels–Alder cycloaddition–dehydration reactions of ethylene and the dimethyl ester of furan-2,5-dicarboxilic acid.

09 BIOMASS FUELS↗

Evaluation of Technologies to Prevent Precipitation During Water Recovery from Urine

The International Space Station (ISS) Urine Processor Assembly (UPA) experienced a hardware failure in the Distillation Assembly (DA) in October 2010. Initially the UPA was operated to recover 85% of the water from urine through distillation, concentrating the contaminants in the remaining urine. The DA failed due to precipitation of calcium sulfate (gypsum) which caused a loss of UPA function. The ISS UPA operations have been modified to only recover 70% of the water minimizing gypsum precipitation risk but substantially increasing water resupply needs. This paper describes the feasibility assessment of several technologies (ion exchange, chelating agents, threshold inhibitors, and Lorentz devices) to prevent gypsum precipitation. The feasibility assessment includes the development of assessment methods, chemical modeling, bench top testing, and validation testing in a flight-like ground UPA unit. Ion exchange technology has been successfully demonstrated and has been recommended for further development. The incorporation of the selected technology will enable water recovery to be increased from 70% back to the original 85% and improve the ISS water balance.

Broyan, James L., Jr.↗

Ionomer Optimization for Water Uptake and Swelling in Anion Exchange Membrane Electrolyzer: Hydrogen Evolution Electrode

Green hydrogen produced through anion exchange membrane water electrolysis is a promising, low-cost chemical storage solution for intermittent renewable energy sources. Low-temperature electrolysis using anion exchange membranes (AEM) combines the benefits of established water electrolysis technologies based on alkaline electrolysis and proton exchange membrane electrolysis. The anion conductive ionomers (ACI) used in the AEM electrolyzer (AEMEL) electrodes has been investigated. The ACI serves two primary purposes: (i) facilitate hydroxide conduction between the catalyst and bulk electrolyte and (ii) bind the catalyst to the porous transport layer and membrane. High ion exchange capacity (IEC) ACIs are desired, however, high IEC can cause excessive water uptake (WU) and detrimental ACI swelling. Proper water management is a key factor in obtaining maximum performance in AEM-based devices. In this study, a series of poly(norbornene)-based ACIs were synthesized and deployed in hydrogen evolving AEMEL cathode electrodes. A balance between ionic conductivity, WU and ionomer swelling was achieved in the ACI by varying the IEC and degree of polymer cross-linking. It was found that higher IEC ACIs with light crosslinking are preferred in the HER electrode. Furthermore, such a configuration fine-tuned the WU and ionomer swelling to achieve optimum cell performance and reduce cell operating voltages.

08 HYDROGEN↗

NanoCapillary Network Proton Conducting Membranes for High Temperature Hydrogen/Air Fuel Cells

The objective of this proposal is to fabricate and characterize a new class of NanoCapillary Network (NCN) proton conducting membranes for hydrogen/air fuel cells that operate under high temperature, low humidity conditions. The membranes will be intelligently designed, where a high density interconnecting 3-D network of nm-diameter electrospun proton conducting polymer fibers is embedded in an inert (uncharged) water/gas impermeable polymer matrix. The high density of fibers in the resulting mat and the high ion-exchange capacity of the fiber polymer will ensure high proton conductivity. To further enhance water retention, molecular silica will be added to the sulfonated polymer fibers. The uncharged matrix material will control water swelling of the high ion-exchange capacity proton conducting polymer fibers and will impart toughness to the final nanocapillary composite membrane. Thus, unlike other fuel cell membranes, the role of the polymer support matrix will be decoupled from that of the proton-conducting channels. The expected final outcome of this 5-year project is the fabrication of fuel cell membranes with properties that exceed the DOE’s technical targets, in particular a proton conductivity of 0.1 S/cm at a temperature less than or equal to120°C and 25-50% relative humidity.

30 DIRECT ENERGY CONVERSION↗

TiO{sub 2} nanotube, nanowire, and rhomboid-shaped particle thin films fixed on a titanium metal plate

Titanium dioxide thin films having various nanostructures could be formed by various treatments on sodium titanate nanotube thin films approximately 5 {mu}m thick fixed on titanium metal plates. Using an aqueous solution with a lower hydrochloric acid concentration (0.01 mol/L) and a higher reaction temperature (90 deg. C) than those previously employed, we obtained a hydrogen titanate nanotube thin film fixed onto a titanium metal plate by H{sup +} ion-exchange treatment of the sodium titanate nanotube thin film. Calcination of hydrogen titanate nanotube thin films yielded porous thin films consisting of anatase nanotubes, anatase nanowires, and anatase nanoparticles grown directly from the titanium metal plate. H{sup +} ion-exchange treatment of sodium titanate nanotube thin films at 140 deg. C resulted in porous thin films consisting of rhomboid-shaped anatase nanoparticles. - Graphical abstract: Titanium dioxide nanotube, nanowire, and rhombic particle thin films could be formed by various treatments on a sodium titanate nanotube thin film fixed on a titanium metal plate.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cesium Removal from SY-101 Tank Waste Using Crystalline Silicotitanate

The newly operational Tank Side Cesium Removal (TSCR) system removes radioactive cesium-137 ( 137 Cs) and solids from tank waste supernate in the 200 east area of the Hanford site. Efforts to expand the removal capabilities to the 200 west area are underway by a system anticipated to be called the West Area Risk Management (WARM) system. Laboratory-scale ion exchange processing using expected WARM unit operations were conducted to contribute toward Washington River Protection Solutions (WRPS) establishing accurate process flowsheets for the individual feed campaigns planned for the west area supernate pretreatment. This report describes the small-scale ion exchange testing with 8.0 L of filtered supernate from tank 241-SY-101 (referred to as SY-101) at 16 °C (62 °F) to demonstrate processing conditions that would be prototypic of what the WARM system may experience. One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the SY-101 tank waste to meet this criterion, only 0.44% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 227. Testing with SY-101 matched current TSCR prototypic operations where a lead-lag configuration is used until the lag column reached the WAC limit. Neither the lead nor lag columns reached the WAC, so a polish column was never utilized during this test. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitate (CST) bed, matched the current flowrate at TSCR (an expected flowrate to be used at WARM). The lead column only reached 0.09% Cs breakthrough after processing ~1363 BVs of feed. Cesium breakthrough from the lag column was not observed during the entire processing. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics. Table S.1 and Figure S.1 also summarize the measured SY-101 Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Venting of a Resin Slurry

A resin slurry venting analysis was conducted to address safety issues associated with over-pressurization of ion exchange columns used in the plutonium uranium redox extraction (PUREX) process at the U. S. Department of Energy’s (DOE’s) Savannah River Site (SRS). If flow to these columns were inadvertently interrupted, an exothermic runaway reaction could occur between the ion exchange resin and the nitric acid used in the feed stream. The nitric acid-resin reaction generates significant quantities of noncondensable gases, which would pressurize the column. To prevent the column from rupturing during such events, rupture disks are installed on the column vent lines. The venting analysis models accelerating rate calorimeter (ARC) tests and data from tests that were performed in a vented test vessel with a rupture disk. The tests showed that the pressure inside the test vessel continued to increase after the rupture disk opened, though at a slower rate than prior to the rupture. The increase in the vessel pressure is modeled as a transient phenomenon associated with expansion of the resin slurry/gas mixture upon rupture of the disk. It is postulated that the maximum pressure at the end of this expansion is limited by energy minimization to approximately 1.5 times the rupture disk burst pressure. The magnitude of this pressure increase is consistent with the measured pressure transients. The results of this analysis demonstrate the need to allow for a margin between the design pressure and the rupture disk burst pressure in similar applications.

42 ENGINEERING↗

A High-Rate Aqueous Proton Battery Delivering Power Below -78 °C via an Unfrozen Phosphoric Acid

Lithium-sulfur batteries are attractive for automobile and grid applications due to their high theoretical energy density and the abundance of sulfur. Despite the significant progress in cathode development, lithium metal degradation and the polysulfide shuttle remain two critical challenges in the practical application of Li-S batteries. Development of advanced electrolytes has become a promising strategy to simultaneously suppress lithium dendrite formation and prevent polysulfide dissolution. Here, a new class of concentrated siloxane-based electrolytes, demonstrating significantly improved performance over the widely investigated ether-based electrolytes are reported in terms of stabilizing the sulfur cathode and Li metal anode as well as minimizing flammability. Through a combination of experimental and computational investigation, it is found that siloxane solvents can effectively regulate a hidden solvation-ion-exchange process in the concentrated electrolytes that results from the interactions between cations/anions and solvents. As a result, it could invoke a quasi-solid-solid lithiation and enable reversible Li plating/stripping and robust solid-electrolyte interphase chemistries. The solvation-ion-exchange process in the concentrated electrolytes is a key factor in understanding and designing electrolytes for other high-energy lithium metal batteries.

25 ENERGY STORAGE↗

Characterization of a mock up nuclear waste package using energy resolved MeV neutron analysis

Reliable radiographic methods for characterizing nuclear waste packages non-destructively (without the need to open containers) have the potential to significantly contribute to safe handling and future disposal options, particularly for legacy waste of unknown content. Due to required shielding of waste containers and the need to characterize materials consisting of light elements, X-ray methods are not suitable. Here, energy-resolved MeV neutron radiography is demonstrated as a first-of-its-kind application for non-destructive and remote examination of mock up nuclear waste packages from a safe position using time-of-flight techniques enabled by a novel event-mode imaging detector system. Energy-resolved neutron transmission spectra were measured spatially, permitting the detection of analogue materials to actual nuclear waste such as water, melamine, and ion exchange resin within a 2.54 cm wall thickness steel pipe. The results demonstrate the capability to locate the materials through this wall thickness by radiography and tomographic reconstruction, revealing detailed 3D distributions and structural anomalies. The method effectively detects residual water in ion exchange resin, highlighting its sensitivity to moisture content, a crucial parameter for nuclear waste characterization. Monte Carlo simulations are in agreement with the experimental findings, providing a pathway to simulate waste forms more difficult to tackle experimentally. This work paves the way to apply sub-nanosecond intense MeV neutron sources, such as laser-driven neutron sources under development, to nuclear waste characterization.

36 MATERIALS SCIENCE↗

Momentum transfer in relativistic heavy ion charge-exchange reactions

Relativistic heavy ion charge-exchange reactions yield fragments (Delta-Z = + 1) whose longitudinal momentum distributions are downshifted by larger values than those associated with the remaining fragments (Delta-Z = 1, -2,...). Kinematics alone cannot account for the observed downshifts; therefore, an additional contribution from collision dynamics must be included. In this work, an optical model description of collision momentum transfer is used to estimate the additional dynamical momentum downshift. Good agreement between theoretical estimates and experimental data is obtained.

Townsend, L. W.↗

Origins of Enhanced Ion Transport in Nanostructured Anion-Conducting Polyelectrolytes

Ion-conducting polymer chemistry and microstructure profoundly impact membrane water uptake and ionic conductivity. Water uptake strongly impacts ionic conductivity; yet excess water uptake compromises ion-exchange membrane mechanical properties. Although nanophase separation has been proposed to overcome this trade-off, it is unclear how polymer backbone architecture governs ionic nanostructure and its subsequent impact on water uptake and conductivity. Here, we integrate experiments and molecular dynamics simulations to elucidate the role of backbone chemistry in governing ionic nanostructure, hydration behavior, and ion transport in anion-conducting polyelectrolytes (ACPs). We systematically investigate hydrocarbon polynorbornene (PNB)-based ACPs with three distinct backbone architectures: vinyl-addition polymerization (VAP), ring-opening metathesis polymerization (ROMP), and hydrogenated ROMP. While maintaining comparable ion exchange capacities (IECs) and identical side-chain chemistry, we isolate the effects of backbone structure. We show that nanophase-separated ionic nanostructures originate in the dry state and evolve upon hydration through heterogeneous water uptake, with water preferentially partitioning into ion-rich domains. This nanophase separation arises from a delicate interplay between ionic segregation propensity and the entropic barrier imposed by backbone stiffness. Specifically, flexible backbones intensify attractive ion–ion interactions by reducing the entropic penalty for backbone deformation, promoting nanophase separation, while rigid backbones suppress ionic nanostructure formation. Nanophase-separated ion domains locally concentrate water upon hydration, which in turn enables the connectivity required for fast transport at lower water concentration values. Furthermore, these findings demonstrate that backbone chemistry can be tuned as a design lever to promote nanophase separation and enhance ion transport without excessive water uptake.

Anions↗

Breadboard wash water renovation system

A total wash water renovation system concept was developed for removing objectionable materials from spacecraft wash water in order to make the water reusable. The breadboard model system described provides for pretreatment with ferric chloride to remove soap by chemical precipitation, carbon adsorption to remove trace dissolved organics, and ion exchange for removal of dissolved salts. The entire system was put into continuous operation and carefully monitored to assess overall efficiency and equipment maintenance problems that could be expected in actual use. In addition, the capacity of the carbon adsorbers and the ion-exchange resin was calculated and taken into consideration in the final evaluation of the system adequacy. The product water produced was well within the Tentative Wash Water Standards with regard to total organic carbon, conductivity, urea content, sodium chloride content, color, odor, and clarity.

Source record↗

Free fatty acid separation and recovery using resin

The disclosure provides various methods for separating and recovering free fatty acids crude oil containing free fatty acids using certain ion-exchange resins to reduce the amount of free fatty acids in the crude oil to 3% or less such that the resultant oil is useable in downstream chemical processes. After separation and removal of the free fatty acids form the crude oil, the ion-exchange resin is reusable in further free fatty acid separation reactions.

Singh, Vijay↗