Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

The Effect of Dose of Nitrogen-Ion Implantation on the Concentration of Point Defects Introduced into GaAs Layers

Secondary-ion mass spectrometry and Rutherford proton backscattering have been used to measure the concentration profiles of nitrogen atoms and examine the defect structure of epitaxial GaAs layers implanted with 250-keV N{sup +} ions at doses of 5 × 10{sup 14}–5 × 10{sup 16} cm{sup –2}. It was found that no amorphization of the layers being implanted occurs at doses exceeding the calculated amorphization threshold, a concentration of point defects that is formed is substantially lower than the calculated value, and a characteristic specific feature of the defect concentration profiles is the high defect concentration in the surface layer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fabrication of single color centers in sub-50 nm nanodiamonds using ion implantation

Diamond color centers have been widely studied in the field of quantum optics. The negatively charged silicon vacancy (SiV – ) center exhibits a narrow emission linewidth at the wavelength of 738 nm, a high Debye–Waller factor, and unique spin properties, making it a promising emitter for quantum information technologies, biological imaging, and sensing. In particular, nanodiamond (ND)-based SiV – centers can be heterogeneously integrated with plasmonic and photonic nanostructures and serve as in vivo biomarkers and intracellular thermometers. Out of all methods to produce NDs with SiV – centers, ion implantation offers the unique potential to create controllable numbers of color centers in preselected individual NDs. However, the formation of single color centers in NDs with this technique has not been realized. We report the creation of single SiV– centers featuring stable high-purity single-photon emission through Si implantation into NDs with an average size of ~20 nm. We observe room temperature emission, with zero-phonon line wavelengths in the range of 730–800 nm and linewidths below 10 nm. Our results offer new opportunities for the controlled production of group-IV diamond color centers with applications in quantum photonics, sensing, and biomedicine.

36 MATERIALS SCIENCE↗

Critical Vacancy-Driven Phenomena in High-Energy Ion-Implanted Silicon

High-energy (MeV) ion implantation is now being rapidly introduced into integrated circuit manufacturing because it promises process simplification and improved device performance. However, high-energy implantation introduces an imbalance of excess vacancies and vacancy-cluster defects in the near-surface region of a silicon crystal. These defects interact with dopants affecting diffusion and electrical activation during subsequent processing. The objective of this project was to develop sufficient understanding of the physical mechanisms underlying the evolution of these defects and interactions with dopant atoms to enable accurate prediction and control of dopant diffusion and defect configurations during processing. This project supported the DOE mission in science and technology by extending ongoing Basic Energy Sciences programs in ion-solid physics and x-ray scattering at ORNL into new areas. It also strengthened the national capability for advanced processing of electronic materials, an enabling technology for DOE programs in energy conversion, use, and defense.

36 MATERIALS SCIENCE↗

Examining metallic glass formation in LaCe:Nb by ion implantation

In order to combine niobium (Nb) with lanthanum (La) and cerium (Ce), Nb ions were deposited within a thin film of these two elements. According to the Hume-Rothery rules, these elements cannot be combined into a traditional crystalline metallic solid. The creation of an amorphous metallic glass consisting of Nb, La, and Ce is then investigated. Amorphous metallic glasses are traditionally made using fast cooling of a solution of molten metals. In this paper, we show the results of an experiment carried out to form a metallic glass by implanting 9 MeV Nb 3+ atoms into a thin film of La and Ce. Prior to implantation, the ion volume distribution is calculated by Monte Carlo simulation using the SRIM tool suite. As a result, using multiple methods of electron microscopy and material characterization, small quantities of amorphous metallic glass are indeed identified.

36 MATERIALS SCIENCE↗

Evaluation of dual-tip micromanometers during 21-day implantation in goats

Investigative research efforts using a cardiovascular model required the determination of central circulatory haemodynamic and arterial system parameters for the evaluation of cardiovascular performance. These calculations required continuous beat-to-beat measurement of pressure within the four chambers of the heart and great vessels. Sensitivity and offset drift, longevity, and sources of error for eight 3F dual-tipped micromanometers were determined during 21 days of implantation in goats. Subjects were instrumented with pairs of chronically implanted fluid-filled access catheters in the left and right ventricles, through which dual-tipped (test) micromanometers were chronically inserted and single-tip (standard) micromanometers were acutely inserted. Acutely inserted sensors were calibrated daily and measured pressures were compared in vivo to the chronically inserted sensors. Comparison of the pre- and post-gain calibration of the chronically inserted sensors showed a mean sensitivity drift of 1.0 +/- 0.4% (99% confidence, n = 9 sensors) and mean offset drift of 5.0 +/- 1.5 mmHg (99% confidence, n = 9 sensors). Potential sources of error for these drifts were identified, and included measurement system inaccuracies, temperature drift, hydrostatic column gradients, and dynamic pressure changes. Based upon these findings, we determined that these micromanometers may be chronically inserted in high-pressure chambers for up to 17 days with an acceptable error, but should be limited to acute (hours) insertions in low-pressure applications.

Non-NASA Center↗

High power impulse magnetron sputtering and related discharges: scalable plasma sources for plasma-based ion implantation and deposition

High power impulse magnetron sputtering (HIPIMS) and related self-sputtering techniques are reviewed from a viewpoint of plasma-based ion implantation and deposition (PBII&D). HIPIMS combines the classical, scalable sputtering technology with pulsed power, which is an elegant way of ionizing the sputtered atoms. Related approaches, such as sustained self-sputtering, are also considered. The resulting intense flux of ions to the substrate consists of a mixture of metal and gas ions when using a process gas, or of metal ions only when using `gasless? or pure self-sputtering. In many respects, processing with HIPIMS plasmas is similar to processing with filtered cathodic arc plasmas, though the former is easier to scale to large areas. Both ion implantation and etching (high bias voltage, without deposition) and thin film deposition (low bias, or bias of low duty cycle) have been demonstrated.

36 MATERIALS SCIENCE↗

Additive Manufacturing of Biomechanically Tailored Meshes for Compliant Wearable and Implantable Devices

Abstract Additive manufacturing (AM) of medical devices such as orthopedic implants and hearing aids is highly attractive because of the potential of AM to match the complex form and mechanics of individual human bodies. Externally worn and implantable tissue‐support devices, such as ankle or knee braces, and hernia repair mesh, offer a new opportunity for AM to mimic tissue‐like mechanics and improve both patient outcomes and comfort. Here, it is demonstrated how explicit programming of the toolpath in an extrusion AM process can enable new, flexible mesh materials having digitally tailored mechanical properties and geometry. Meshes are fabricated by extrusion of thermoplastics, optionally with continuous fiber reinforcement, using a continuous toolpath that tailors the elasticity of unit cells of the mesh via incorporation of slack and modulation of filament–filament bonding. It is shown how the tensile mesh mechanics can be engineered to match the nonlinear response of muscle. An ankle brace with directionally specific inversion stiffness arising from embedded mesh is validated, and further concepts for 3D mesh devices are prototyped.

Pattinson, Sebastian W.↗

How Small Can We Go? Evaluating Survival, Tag Retention, and Growth of Juvenile Chinook Salmon Implanted with a New Acoustic Microtag

Abstract Recently, an acoustic microtag, called the Eel–Lamprey Acoustic Tag (ELAT), was developed for use in juvenile American Eel Anguilla rostrata and Pacific Lamprey Entosphenus tridentatus. The ELAT (12.0 × 2.0 mm; 0.088 g in air) has the potential to be used to study other small-bodied fishes. In this pilot study, juvenile Chinook Salmon Oncorhynchus tshawytscha 52–99 mm fork length (FL) were surgically implanted with an ELAT (n = 99) or remained untagged (control; n = 101). Fish were held for 30 d to evaluate survival, tag retention, and growth. Survival did not differ significantly between control (n = 98 or 97.0%) and tagged fish (n = 95 or 95.9%). Logistic regression analysis suggested that survival was influenced by initial FL and tag burden. Mortalities only occurred in tagged fish with initial FLs of ≤65 mm (FL range = 57–65 mm; tag burdens = 3.8–5.9%). However, a tagged fish with an initial FL of 62 mm or an initial tag burden of 4.1% (FL range = 58–64 mm) was predicted to have a 90% chance of survival, and the smallest fish that survived the study was 54 mm FL (1.8 g; tag burden = 4.9%). Tag retention was high (99%), with only one fish expelling an ELAT during the study. Control fish grew slightly larger than the tagged individuals, but differences in final pooled FLs and weight gains were not significant. Our results demonstrate the successful surgical implantation of the ELAT into Chinook Salmon as small as 54 mm FL (1.8 g).

59 BASIC BIOLOGICAL SCIENCES↗

FDG-MicroPET and Diffusion-Weighted MR Image Evaluation of Early Changes After Radiofrequency Ablation in Implanted VX2 Tumors in Rabbits

The objective of this study was to evaluate the early changes after radiofrequency ablation (RFA) in VX2 rabbit tumors implanted into the back muscles by diffusion-weighted magnetic resonance (MR) imaging and {sup 18}F-2-fluoro-2-deoxy-D-glucose positron emission tomography ({sup 18}F-FDG PET). Percutaneous CT-guided RFA was conducted in seven rabbits with implanted VX2 tumors. VX2 tumors on the other side were untreated and served as the control. MR imaging was performed with a clinical 1.5-T instrument 2 days after RFA, and FDG-PET, using a high-resolution PET scanner for small animals, was obtained 3 days after the procedure. The mean apparent diffusion coefficient (ADC) values and radioactivity count of untreated and ablated tumors were calculated. Untreated VX2 tumors showed hyperintensity on T1-, T2-, and diffusion-weighted MR images, ring-enhanced on contrast-enhanced T1-weighted imaging, and ring-shaped FDG accumulation on FDG-PET. Ablated VX2 tumors showed slight hyperintensity on T1-, T2-, and diffusion-weighed images, slight enhancement on contrast-enhanced T1-weighted images, and low accumulation on FDG-PET. The ADC value of ablated VX2 tumors (1.52 {+-} 0.24 x 10{sup -3} mm{sup 2}/s) was significantly higher than that of untreated tumors (1.09 {+-} 0.12 x 10{sup -3}; p < 0.05). The tumor/muscle ratio of ablated tumors (0.5 {+-} 0.3) was significantly lower than that of untreated tumors (11.6 {+-} 3.2; p < 0.05). Histopathological examination confirmed the lack of viable tumor cells in the ablated lesions. The results indicate that both ADC value and FDG-PET are potentially useful markers for monitoring the early effects of RFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Arterial Infusion and Stent Implantation Compared with Metal Stent Alone in Treatment of Malignant Gastroduodenal Obstruction

Many patients with malignant gastroduodenal obstruction have an unresectable primary lesion and distant metastases, which may prompt palliative management to allow the patient to eat and to improve the quality of life. Intraluminal metallic stent implantation (MSI) under fluoroscopic guidance has been reported to be an effective option for symptomatic relief in these patients, with a good safety record. An alternative, dual interventional therapy (DIT), has been used during the last decade, in which prosthesis insertion is followed by intra-arterial chemotherapy via the tumor-feeding arteries. The aim of this study was to compare success rates, complication rates, and survival time between MSI and DIT in patients who presented with gastroduodenal obstruction from advanced upper gastrointestinal tract cancer. All consecutive patients with malignant gastroduodenal obstruction seen at our center between October 2002 and August 2007 were retrospectively studied. Patients were treated palliatively by either MSI or DIT by the patient's or the next of kin's decision. Outcomes included technical and clinical success, complication rates, and survival. Of the 164 patients with malignant gastric and duodenal outlet obstructions, 80 (49%) underwent stent insertion as the primary therapy, while the remaining 84 (51%) received DIT. Clinical characteristics were similar between the two groups. In the MSI cohort initial stent implantation was successful in 73 patients (91%), two stents were used in 5 patients, and delayed additional stent insertion for stent obstruction related to tumor overgrowth was required in 3 patients during follow-up. In the DIT cohort the technical success rate was 94%, 3 patients required two stents, and stent obstruction occurred in 2 patients after initial stent placement. Early postprocedural clinical success, indicated by average dysphagia score, improved significantly in both groups: MSI group, from 4.56 to 1.51 (P < 0.01); and DIT group, from 4.38 to 1.48 (p < 0.01). There were no short-term complications. Late complications including hematemesis (n = 3), migration (n = 12), and stent occlusion due to tumor overgrowth (n = 5) were evenly distributed between the groups. In the DIT group chemotherapy-induced neutropenia and transient renal dysfunction were detected in six patients, which improved after symptomatic management. Mean survival time after the procedure was 5.9 and 11.1 months for MSI and DIT, respectively (P < 0.001). In conclusion, both MSI and DIT offer effective palliation for malignant gastroduodenal obstruction, but DIT appears to offer superior survival over MSI alone. Ideally, a prospective randomized trial comparing these two techniques should be carried out to validate this result.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Central Vein Dilatation Prior to Concomitant Port Implantation

Implantation of subcutaneous port systems is routinely performed in patients requiring repeated long-term infusion therapy. Ultrasound- and fluoroscopy-guided implantation under local anesthesia is broadly established in interventional radiology and has decreased the rate of complications compared to the surgical approach. In addition, interventional radiology offers the unique possibility of simultaneous management of venous occlusion. We present a technique for recanalization of central venous occlusion and angioplasty combined with port placement in a single intervention which we performed in two patients. Surgical port placement was impossible owing to occlusion of the superior vena cava following placement of a cardiac pacemaker and occlusion of multiple central veins due to paraneoplastic coagulopathy, respectively. In both cases the affected vessel segments were dilated with balloon catheters and the port systems were placed thereafter. After successful dilatation, the venous access was secured with a 25-cm-long, 8-Fr introducer sheath, a subcutaneous pocket prepared, and the port catheter tunneled to the venipuncture site. The port catheter was introduced through the sheath with the proximal end connected to a 5-Fr catheter. This catheter was pulled through the tunnel in order to preserve the tunnel and, at the same time, allow safe removal of the long sheath over the wire. The port system functioned well in both cases. The combination of recanalization and port placement in a single intervention is a straightforward alternative for patients with central venous occlusion that can only be offered by interventional radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis

Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access-the subclavian vein and arm vein-in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achieved in all patients. The median follow-up period was 94 (range, 1-891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Repair of a Perforation of the Vena Caval Wall Caused by the Retrieval of a Gunther Tulip Filter After Long-Term Implantation

Symptomatic penetration of the inferior vena cava (IVC) wall reportedly occurs in 0.3% of patients in whom a filter has been implanted, and it causes injury to the adjacent structures (Bogue et al. in Pediatr Radiol 39(10):1110-1113, 1; Brzezinski et al. in Burns 32(5):640-643, 2). We succeeded in the endovascular repair of perforation of the IVC wall occurring during the retrieval of a penetrated Gunther tulip vena cava filter (Cook, Bjaeverskov, Denmark) after long-term implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of Vessel Size and Tortuosity on In-stent Restenosis After Stent Implantation in the Vertebral Artery Ostium

Purpose: Percutaneous transluminal angioplasty and stenting is emerging as an alternative for treating atherosclerotic stenosis in the vertebral artery ostium. However, in-stent restenosis (ISR) still remains a critical issue to be addressed. Little is known about the relationship between anatomic characteristics of the artery and ISR after stent implantation. In this study, we have evaluated influential factors for ISR in a cohort of the patients with stenting in the vertebral artery ostium. Methods: Sixty-one patients with 63 symptomatic lesions in vertebral artery ostium treated with stenting were enrolled onto this study. An average of 12.5 months' clinical and angiographic follow-up results were analyzed retrospectively. The possible influential factors for ISR, including conventional risk factors of cerebrovascular diseases and morphological characteristics of target lesions, were evaluated by univariate and multivariate regression analysis. Results: Technical success was achieved in all 63 interventional procedures. Stenosis was reduced from (mean {+-} standard deviation) 75.5 {+-} 12% before to 1 {+-} 3.6% after the procedure. During the mean 12.5-month angiographic follow-up, ISR was detected in 17 treated vessels (27.0%), with 2 treated arteries (3.2%) resulting in occlusion, and a stent fracture in 1 case (1.6%). Multivariate Cox regression analysis showed that the tortuosity of V1 (hazard ratio 3.54, P = 0.01) and smaller diameter of the stent (hazard ratio 3.8, P = 0.04) were independent predictors of ISR. Conclusions: Angioplasty and stenting for symptomatic stenosis in the vertebral artery ostium stenosis seem to be feasible and effective. Tortuosity and smaller diameter may affect ISR after stent implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Perigraft Plug Embolization of the Internal Iliac Artery and Implantation of a Bifurcated Stentgraft: One Treatment Option for Insufficient Tubular Stentgraft Repair of a Common Iliac Artery Aneurysm

We report an endovascular technique for the treatment of type Ia endoleak after a plain tubular stentgraft had been implanted for a large common iliac artery aneurysm with an insufficient proximal landing zone and without occlusion of the hypogastric in another hospital. CT follow-up showed an endoleak with continuous sac expansion over 12 months. This was classified as type Ia by means of dynamic contrast-enhanced MRI. Before a bifurcated stentgraft was implanted to relocate the landing zone more proximally, the still perfused ipsilateral hypogastric artery was embolized to prevent a type II endoleak. A guidewire was manipulated alongside the indwelling stentgraft. The internal iliac artery could then be selectively intubated followed by successful plug embolization of the vessel’s orifice despite the stentgraft being in place.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding heterogeneity in Genesis diamond-like carbon film using SIMS analysis of implants

An amorphous diamond-like carbon film deposited on silicon made at Sandia National Laboratory by pulsed laser deposition was one of several solar wind (SW) collectors used by the Genesis Mission (NASA Discovery Class Mission #5). The film was ~1 μm thick, amorphous, anhydrous, and had a high ratio of sp 3 –sp 2 bonds (>50%). For 27 months of exposure to space at the first We passively irradiated lagrange point, the collectors, with SW (H fluence ~2 × 10 16 ions cm -2 ; He fluence ~8 × 10 14 ions cm -2 ). The radiation damage caused by the implanted H ions peaked at 12–14 nm below the surface of the film and that of He about 20–23 nm. To enable quantitative measurement of the SW fluences by secondary ion mass spectroscopy, minor isotopes of Mg ( 25 Mg and 26 Mg) were commercially implanted into flight-spare collectors at 75 keV and a fluence of 1 × 10 14 ions cm -2 . Furthermore, the shapes of analytical depth profiles, the rate at which the profiles were sputtered by a given beam current, and the intensity of ion yields are used to characterize the structure of the material in small areas (~200 × 200 ± 50 μm). Data were consistent with the hypothesis that minor structural changes in the film were induced by SW exposure.

36 MATERIALS SCIENCE↗

An introduction to the practical and ethical perspectives on the need to advance and standardize the intracoelomic surgical implantation of electronic tags in fish

The intracoelomic surgical implantation of electronic tags (including radio and acoustic telemetry transmitters, passive integrated transponders and archival biologgers) is frequently used for conducting studies on fish. Electronic tagging studies provide information on the spatial ecology, behavior and survival of fish in marine and freshwater systems. However, any surgical procedure, particularly one where a laparotomy is performed and the coelomic cavity is opened, has the potential to alter the survival, behavior or condition of the animal which can impair welfare and introduce bias. Given that management, regulatory and conservation decisions are based on the assumption that fish implanted with electronic tags have similar fates and behavior relative to untagged conspecifics, it is critical to ensure that best surgical practices are being used. Also, the current lack of standardized surgical procedures and reporting of specific methodological details precludes cross-study and cross-year analyses which would further progress the field of fisheries science. This compilation of papers seeks to identify the best practices for the entire intracoelomic tagging procedure including pre- and post-operative care, anesthesia, wound closure, and use of antibiotics. Although there is a particular focus on salmonid smolts given the large body of literature available on that group, other life-stages and species of fish are discussed where there is sufficient knowledge. Additional papers explore the role of the veterinarian in fish surgeries, the need for minimal standards in the training of fish surgeons, providing a call for more complete and transparent procedures, and identifying trends in procedures and research needs. Collectively, this body of knowledge should help to improve data quality (including comparability and repeatability), enhance management and conservation strategies, and maintain the welfare status of tagged fish.

60 APPLIED LIFE SCIENCES↗