On the complex structure of the optical spectra of a tetragonal calomel single crystal in a wide energy range

The spectral complex of optical functions of the calomel Hg{sub 2}Cl{sub 2} single crystal is determined in the range 0–20 eV at 300 K in unpolarized light. The spectra of the imaginary part of the permittivity ε{sub 2}(E), the bulk–Imε{sup –1} and the surface–Im(1 + ε){sup –1} electron energy losses are decomposed into elementary bands. Their main parameters, including energies and oscillator strengths of the transition bands are determined. Calculations are performed on the basis of the experimental reflectance spectrum of the crystal cleavage. Computer programs based on Kramers–Kronig relations, analytical formulas, and the advanced parameterfree method of combined Argand diagrams are used. The main features of the spectral set of optical functions and the parameters of expansion band components ε{sub 2}(E),–Imε{sup –1}, and–Im(1 + ε){sup –1} are determined.

36 MATERIALS SCIENCE↗

AdS/QCD, Light-Front Holography, and the Nonperturbative Running Coupling

We have analyzed the beam spin asymmetry and the longitudinally polarized target spin asymmetry of the Deep Virtual Compton Scattering process, recently measured by the Jefferson Lab CLAS collaboration. Our aim is to extract information about the Generalized Parton Distributions of the proton. By fitting these data, in a largely model-independent procedure, we are able to extract numerical values for the two Compton Form Factors $H_{Im}$ and $\tilde{H}_{Im}$ with uncertainties, in average, of the order of 30%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Excited state electron transfer in A 2 and A 2 B 2 functionalized zinc porphyrins carrying rigid and flexible β -pyrrole π-extended substituents

Optical absorption and emission, electrochemical, and photochemical properties of peripherally functionalized with flexible and rigid π-extended substituents on A 2 and A 2 B 2 type zinc porphyrins is investigated. The significance of rigid π-substituents over flexible ones in governing the spectral properties is unraveled. Flexible π-substituents on the porphyrin ring caused appreciable spectral broadening compared to porphyrin carrying rigid π-substituents. Further, supramolecular dyads are formed by coordinating phenyl imidazole functionalized fullerene, C 60 Im. Here, the calculated binding constants for the 1:1 complexes is in the order of 2–7 × 10 5 M −1 suggesting stable complex formation. Free-energy calculations performed according to the Rehm–Weller approach suggested possibility of excited state electron transfer in these dyads. Femtosecond transient absorption studies of the dyads performed in o-dichlorobenzene showed evidence of occurrence of electron transfer from the singlet-excited state that was in competition with the intersystem crossing process to populate the triplet-excited state of porphyrins.

A2 and A2B2 functionalized zinc↗

Metabolomics Collision Cross Section Database and Server

This is a the code and data for a website created to display collision cross section data for metabolites and small molecules. This repository hosts two things. First is the source code (js) for a website created to display collision cross section data for metabolites and other small molecules. The second is the underlying CCS dataset. The growing interest in metabolomic and exposomic studies is also inciting a need for new techniques to analyze these diverse molecules. Mass spectrometry-based studies are often preferred for the confident identification of small molecules. Ion mobility spectrometry (IMS) is capable of separating molecules that have the same m/z but different conformational arrangements, which is very useful in metabolomic and exposomic analyses. As the desire for IMS measurements of metabolites continues to grow, so does the need for high quality collision cross section (CCS) values.

Payne, Sam↗

EMSL-Computing/PeakDecoder

PeakDecoder is a machine learning (ML)-based metabolite identification algorithm for multidimensional mass spectrometry measurements incorporating liquid chromatography (LC) and ion mobility spectrometry (IM) separations, and collecting extensive fragmentation spectra with data-independent acquisition (DIA) methods: LC-IM-DIA-MS. The algorithm learns to distinguish true co-elution and co-mobility from raw data and calculates metabolite identification error rates.

Bilbao Pena, Aivett↗

Serum biomarkers of Burkholderia mallei infection elucidated by proteomic imaging of skin and lung abscesses

Background: The bacterium Burkholderia mallei is the etiological agent of glanders, a highly contagious, often fatal zoonotic infectious disease that is also a biodefense concern. Clinical laboratory assays that analyze blood or other biological fluids are the highest priority because these specimens can be collected with minimal risk to the patient. However, progress in developing sensitive assays for monitoring B. mallei infection is hampered by a shortage of useful biomarkers. Results: Reasoning that there should be a strong correlation between the proteomes of infected tissues and circulating serum, we employed imaging mass spectrometry (IMS) of thin-sectioned tissues from Chlorocebus aethiops (African green) monkeys infected with B. mallei to localize host and pathogen proteins that were associated with abscesses. Using laser-capture microdissection of specific regions identified by IMS and histology within the tissue sections, a more extensive proteomic analysis was performed by a technique that combined the physical separation capabilities of liquid chromatography (LC) with the sensitive mass analysis capabilities of mass spectrometry (LC-MS/MS). By examining standard formalin-fixed, paraffin-embedded tissue sections, this strategy resulted in the identification of several proteins that were associated with lung and skin abscesses, including the host protein calprotectin and the pathogen protein GroEL. Elevated levels of calprotectin detected by ELISA and antibody responses to GroEL, measured by a microarray of the bacterial proteome, were subsequently detected in the sera of C. aethiops, Macaca mulatta, and Macaca fascicularis primates infected with B. mallei. Conclusions: Our results demonstrate that a combination of multidimensional MS analysis of traditional histology specimens with high-content protein microarrays can be used to discover lead pairs of host-pathogen biomarkers of infection that are identifiable in biological fluids.

59 BASIC BIOLOGICAL SCIENCES↗

Application of laser photofragmentation-resonance enhanced multiphoton ionization to ion mobility spectrometry

We demonstrate detection of nitro-containing compounds with laser photofragmentation (PF) coupled with resonance enhanced multiphoton ionization (REMPI) and ion mobility spectrometry (IMS). In PF-REMPI, a laser dissociates the parent molecules, producing fragments that can then be ionized by absorption of additional laser photons. The production of these ions strongly depends on the wavelength of laser light, with ion yields corresponding to the absorption spectrum of the fragments [nitric oxide (NO) in the present case]. Combining IMS with PF-REMPI provides further specificity, separating ions according to their mobilities through an atmospheric-pressure drift tube. In this work, we use a pulsed UV laser to examine the characteristics of atmospheric-pressure PF-REMPI, the chemistry occurring in the ionization region and drift tube, and the viability of detecting ions created by both resonance-enhanced and nonresonant ionization. Probing NO in a helium-nitrogen bath, we demonstrate that the detection of ions displays single-shot response to changes in ion generation, with an ion extraction-to-collection efficiency of {approx}12%. We then evaluate the sensitivity and specificity of PF-REMPI/IMS as applied to the detection of both the explosive surrogate 2, 4-dinitrotoluene and the nuisance compound nitrobenzene.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nutritional markers and proteome in patients undergoing treatment for pulmonary tuberculosis differ by geographic region

Contemporary phase 2 TB disease treatment clinical trials have found that microbiologic treatment responses differ between African versus non-African regions, the reasons for which remain unclear. Understanding host and disease phenotypes that may vary by region is important for optimizing curative treatments. We characterized clinical features and the serum proteome of phase 2 TB clinical trial participants undergoing treatment for smear positive, culture-confirmed TB, comparing host serum protein expression in clinical trial participants enrolled in African and Non-African regions. Serum samples were collected from 289 participants enrolled in the Centers for Disease Control and Prevention TBTC Study 29 (NCT00694629) at time of enrollment and at the end of the intensive phase (after 40 doses of TB treatment). After a peptide level proteome analysis utilizing a unique liquid chromatography IM-MS platform (LC-IM-MS) and subsequent statistical analysis, a total of 183 core proteins demonstrated significant differences at both baseline and at week 8 timepoints between participants enrolled from African and non-African regions. The majority of the differentially expressed proteins were upregulated in participants from the African region, and included acute phase proteins, mediators of inflammation, as well as coagulation and complement pathways. Downregulated proteins in the African population were primarily linked to nutritional status and lipid metabolism pathways. We have identified differentially expressed nutrition and lipid pathway proteins by geographic region in TB patients undergoing treatment for pulmonary tuberculosis, which appear to be associated with differential treatment responses. Future TB clinical trials should collect expanded measures of nutritional status and further evaluate the relationship between nutrition and microbiologic treatment response.

59 BASIC BIOLOGICAL SCIENCES↗

NGEE Arctic Integrated Modeling (IM3): Improved snow-vegetation interaction

This data product represents the integration of new code capability for arctic tundra snow-vegetation-terrain interactions into the Energy Exascale Earth System Model (E3SM), through the E3SM Land Model (ELM) component. This code integration is the result of collaborative effort between the NGEE Arctic project and the E3SM project. The NGEE Arctic project developed a total of six Integrated Modeling (IM) modules informed by observations and experiments. New ELM capability represented by this data product (IM3) falls into three categories: 1) Downscaling from gridcell to topographic unit level when working through the existing coupler bypass code. 2) Four new parameters (taper, stocking, bendresist, and vegshape) have been added to ELM to allow for flexible definition of snow-vegetation interactions. 3) Vegshape and bendresist parameters are used to calculate the fraction of leaf area and/or stem area buried by snow for a given snow depth. This data record consists of a single document (pdf format) that describes the theoretical basis for the snow-vegetation-terrain interactions added to ELM, and describes the modifications made to the ELM code. The Methods section of this metadata record includes a link to the public E3SM code repository where the exact code modifications as integrated in E3SM can be accessed. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

Thornton, Peter E [ORNL] (ORCID:0000000247595158)↗

Threshold magnitudes for a multichannel correlation detector in background seismicity

Colocated explosive sources often produce correlated seismic waveforms. Multichannel correlation detectors identify these signals by scanning template waveforms recorded from known reference events against "target" data to find similar waveforms. This screening problem is challenged at thresholds required to monitor smaller explosions, often because non-target signals falsely trigger such detectors. Therefore, it is generally unclear what thresholds will reliably identify a target explosion while screening non-target background seismicity. Here, we estimate threshold magnitudes for hypothetical explosions located at the North Korean nuclear test site over six months of 2010, by processing International Monitoring System (IMS) array data with a multichannel waveform correlation detector. Our method (1) accounts for low amplitude background seismicity that falsely triggers correlation detectors but is unidentifiable with conventional power beams, (2) adapts to diurnally variable noise levels and (3) uses source-receiver reciprocity concepts to estimate thresholds for explosions spatially separated from the template source. Furthermore, we find that underground explosions with body wave magnitudes m b = 1.66 are detectable at the IMS array USRK with probability 0.99, when using template waveforms consisting only of P -waves, without false alarms. We conservatively find that these thresholds also increase by up to a magnitude unit for sources located 4 km or more from the Feb.12, 2013 announced nuclear test.

54 ENVIRONMENTAL SCIENCES↗

Anomaly Detection in Seismic Data with Deep Learning: Application for Instrument Failure Detection and Forecasting

Seismic data quality assessment (QA) is the first and one of the most important steps before conducting any further data analysis. Traditional methods involve checking various metrics, such as spike detection and power spectral density, by setting strict thresholds or comparing data against synthetic benchmarks. However, these approaches often rely on pre-existing knowledge and assumptions about data anomalies, leading to potential misclassification of unusual cases. Here, in this study, we propose a deep autoencoder model, an unsupervised learning approach that evaluates data quality without making assumptions about normal and anomalous data, which can be used to identify deviations in recorded data that may indicate nascent instrument failure. We test the model with the U.S. International Monitoring System (IMS) seismic stations and demonstrate the capability of detecting anomalies on a monthly scale. This could prompt station operators to examine potential problems early, allowing sufficient time for instrument maintenance to prevent data outages. In addition, we use a new manually selected testing dataset to compare our model performance against two supervised machine learning (ML) approaches and a standard QA package, as baseline models. When applied to the dataset containing known data anomalies, performance of the supervised and unsupervised ML approaches is similar, with an accuracy of 88.1% for our model compared to ∼90% for the supervised ML approach and 78.2% for the standard QA package. Our model outperforms the baseline models when applied to new stations, where new types of data anomalies can be station-specific and not included in the training dataset. Finally, we show model transferability by training the model with data from the Global Seismograph Network only and applying it to the IMS network data. The results suggest that our model is generalizable and can be applied to new stations with good accuracy.

Lin, Jiun-Ting [Lawrence Livermore National Labora↗

Annual Report of Groundwater Monitoring at Centralia, Kansas, in 2011

Periodic sampling is performed at Centralia, Kansas, on behalf of the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) by Argonne National Laboratory, in accord with the current interim monitoring program approved by the Kansas Department of Health and Environment (KDHE 2009). The objective is to monitor levels of carbon tetrachloride contamination identified in the groundwater sitewide (Argonne 2003, 2004, 2005a), as well as the response to the interim measure (IM) pilot test that is in progress (Argonne 2007b). An earlier monitoring plan (Argonne 2005b) was also approved by the KDHE (2005). Under this earlier plan, the groundwater was sampled twice yearly from September 2005 until September 2007 for analyses for volatile organic compounds (VOCs), as well as measurement of selected geochemical parameters to aid in the evaluation of possible natural contaminant degradation processes (reductive dechlorination) in the subsurface environment (Argonne 2006, 2007a, 2008a). The results from the two-year sampling program demonstrated the presence of carbon tetrachloride contamination at levels exceeding the KDHE Tier 2 risk-based screening level (RBSL) of 5 µg/L for this compound, in a localized groundwater plume that has shown little movement. The relative concentrations of chloroform, the primary degradation product of carbon tetrachloride, suggested that some degree of reductive dechlorination or natural biodegradation was talking place in situ at the former CCC/USDA facility on a localized scale. After two years of monitoring under the earlier plan, the CCC/USDA developed an Interim Measure Conceptual Design (Argonne 2007b), proposing a pilot test of the Adventus EHC technology for in situ chemical reduction (ISCR). The proposed IM was approved by the KDHE in November 2007 (KDHE 2007). Implementation of the pilot test occurred in November-December 2007. The objective was to create highly reducing conditions that would enhance both chemical and biological reductive dechlorination in the injection test area (Argonne 2009a).

LaFreniere, L. M.↗

A General Investigation of Optimized Atmospheric Sample Duration

ABSTRACT The International Monitoring System (IMS) consists of up to 80 aerosol and xenon monitoring systems spaced around the world that have collection systems sensitive enough to detect nuclear releases from underground nuclear tests at great distances (CTBT 1996; CTBTO 2011). Although a few of the IMS radionuclide stations are closer together than 1,000 km (such as the stations in Kuwait and Iran), many of them are 2,000 km or more apart. In the absence of a scientific basis for optimizing the duration of atmospheric sampling, historically scientists used a integration times from 24 hours to 14 days for radionuclides (Thomas et al. 1977). This was entirely adequate in the past because the sources of signals were far away and large, meaning that they were smeared over many days by the time they had travelled 10,000 km. The Fukushima event pointed out the unacceptable delay time (72 hours) between the start of sample acquisition and final data being shipped. A scientific basis for selecting a sample duration time is needed. This report considers plume migration of a nondecaying tracer using archived atmospheric data for 2011 in the HYSPLIT (Draxler and Hess 1998; HYSPLIT 2011) transport model. We present two related results: the temporal duration of the majority of the plume as a function of distance and the behavior of the maximum plume concentration as a function of sample collection duration and distance. The modeled plume behavior can then be combined with external information about sampler design to optimize sample durations in a sampling network.

CTBT↗

Final Report DE-SC0006997; PI Sharp; Coupled Biological and Micro-XAS/XRF Analysis of In Situ Uranium Biogeochemical Processes

Project Overview: The impact of the original seed award was substantially increased by leveraging a postdoctoral fellowship (Marie Curie Postdoctoral Fellowship) and parallel funds from (A) synergistic project supported by NSF and (B) with DOE collaborators (PI’s Ranville and Williams) as well as no-cost extension that greatly increased the impact and publications associated with the project. In aligning with SBR priorities, the project’s focus was extended more broadly to explore coupled biogeochemical analysis of metal (im)mobilization processes beyond uranium with a foundation in integrating microbial ecology with geochemical analyses. This included investigations of arsenic and zinc during sulfate reducing conditions in addition to direct microbial reduction of metals. Complimentary work with NSF funding and collaborative DOE interactions further increased the project scope to investigate metal (im)mobilization coupled to biogeochemical perturbations in forest ecosystems with an emphasis on coupled carbon and metal biogeochemistry. In total, the project was highly impactful and resulted in 9 publications and directly supported salary/tuition for 3 graduate students at various stages of their academic careers as well as my promotion to Associate Professor. In going forward, findings provided inspiration for a two subsequent proposals with collaborators at Lawrence Berkeley Laboratory and others that are currently in review (as of March 2016).

54 ENVIRONMENTAL SCIENCES↗

New approaches for metabolomics by mass spectrometry

Small molecules constitute a large part of the world around us, including fossil and some renewable energy sources. Solar energy harvested by plants and bacteria is converted into energy rich small molecules on a massive scale. Some of the worst contaminants of the environment and compounds of interest for national security also fall in the category of small molecules. The development of large scale metabolomic analysis methods lags behind the state of the art established for genomics and proteomics. This is commonly attributed to the diversity of molecular classes included in a metabolome. Unlike nucleic acids and proteins, metabolites do not have standard building blocks, and, as a result, their molecular properties exhibit a wide spectrum. This impedes the development of dedicated separation and spectroscopic methods. Mass spectrometry (MS) is a strong contender in the quest for a quantitative analytical tool with extensive metabolite coverage. Although various MS-based techniques are emerging for metabolomics, many of these approaches include extensive sample preparation that make large scale studies resource intensive and slow. New ionization methods are redefining the range of analytical problems that can be solved using MS. This project developed new approaches for the direct analysis of small molecules in unprocessed samples, as well as pushed the limits of ultratrace analysis in volume limited complex samples. The projects resulted in techniques that enabled metabolomics investigations with enhanced molecular coverage, as well as the study of cellular response to stimuli on a single cell level. Effectively individual cells became reaction vessels, where we followed the response of a complex biological system to external perturbation. We established two new analytical platforms for the direct study of metabolic changes in cells and tissues following external perturbation. For this purpose we developed a novel technique, laser ablation electrospray ionization (LAESI), for metabolite profiling of functioning cells and tissues. The technique was based on microscopic sampling of biological specimens by mid-infrared laser ablation followed by electrospray ionization of the plume and MS analysis. The two main shortcomings of this technique had been limited specificity due to the lack of a separation step, and limited molecular coverage, especially for nonpolar chemical species. To improve specificity and the coverage of the metabolome, we implemented the LAESI ion source on a mass spectrometer with ion mobility separation (IMS). In this system, the gas phase ions produced by the LAESI source were first sorted according to their collisional cross sections in a mobility cell. These separated ion packets were then subjected to MS analysis. By combining the atmospheric pressure ionization with IMS, we improved the metabolite coverage. Further enhancement of the non-polar metabolite coverage resulted from the combination of laser ablation with vacuum UV irradiation of the ablation plume. Our results indicated that this new ionization modality provided improved detection for neutral and non-polar compounds. Based on rapid progress in photonics, we had introduced another novel ion source that utilized the interaction of a laser pulse with silicon nanopost arrays (NAPA). In these nanophotonic ion sources, the structural features were commensurate with the wavelength of the laser light. The enhanced interaction resulted in high ion yields. This ultrasensitive analytical platform enabled the MS analysis of single yeast cells. We extended these NAPA studies from yeast to other microorganisms, including green algae (Chlamydomonas reinhardtii) that captured energy from sunlight on a massive scale. Combining cellular perturbations, e.g., through environmental changes, with the newly developed single cell analysis methods enabled us to follow dynamic changes induced in the cells. In effect, we were able to use individual cells as a “laboratory,” and approached the long-standing goal of establishing a “lab-in-a-cell.” Model systems for these studies included cells of cyanobacteria (Anabaena), yeast (Saccharomyces cerevisiae), green algae (C. reinhardtii) and Arabidopsis thaliana.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NCI Pilot 3 - Synthetic Data Generation Report

Two methods have been implemented so far: Independent Marginals (IM) and Bayesian Network (BN). In the IM method, it simply estimates individual discrete probability distribution from the available real data for each variable, and then sample from them.

97 MATHEMATICS AND COMPUTING↗

A Micro-Thermionic Ionization Source for Chemical Detection

The major goal of this project was to develop an ionization-based detector that could be integrated into the portable gas chromatography systems currently produced by Defiant Technologies. This new detector would allow Defiant to analyze a broader range of analytes and enter new markets. There was also an interest in testing the new ionization source in an ion mobility spectrometer (IMS) that is produced by Sandia National Laboratories. Not only could this eliminate the need for a radioactive material in the IMS, it would offer Defiant the opportunity to add a whole new product line to their chemical analysis systems. Significant progress was made in the development of a thermionic ionization source (TIS) and detector. Using a MEMs heater was an attractive concept, but it proved to be an unfruitful approach because of the fragility of the devices at elevated temperatures. A rugged alternative heater was developed using nichrome wire and alumina tubes. These heaters are simple to make, and, for low quantity production, will be considerably cheaper to construct than MEMs devices. This work has provided a firm basis for follow-on projects. There is now a solid concept for constructing heater elements where, prior to this work, there was only the hope that MEMs heaters would work. In addition, the electrometer that was developed works better than the commercial rack-mounted system that was originally used in this study. Overcoming these two obstacles provides a clear technical approach for product development. There will be follow on efforts at Defiant Technologies to refine the development of the thermal ionization detector. Designs are being made to combine the TIS and electrometer electronics into a single package with a simple-to-replace TIS element. Further work will also focus on integrating this new detector into portable gas chromatography products and testing to optimize the performance.

47 OTHER INSTRUMENTATION↗

Ultra-Sensitive Measurements of Large-Volume Radioxenon Samples Using an Ultra-Low-Background Proportional Counter (ULBPC) (Final Report)

This project investigated the feasibility of analyzing radioxenon samples in much larger quantities than currently used by the International Monitoring System (IMS). There is interest within the PTS and the international community in the ability to obtain xenon samples using the output of industrial oxygen plants, which could provide samples that are larger by three orders of magnitude, or more, than those currently provided by IMS stations. Such samples would best be analyzed using internal-source gas proportional counters, though the details of that approach and its sensitivity and limits were previously not examined. This report details the outcomes of a task designed to 1) analyze xenon radioisotope data collected previously via internal-source gas proportional counting and 2) collect additional gas proportional counter measurements to determine feasible gas blends for large volume xenon.