Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat conduction modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Steroid responsiveness in alcohol-associated hepatitis is linked to glucocorticoid metabolism, mitochondrial repair, and heat shock proteins

Alcohol-associated hepatitis (AH) is one of the clinical presentations of alcohol-associated liver disease. AH has poor prognosis, and corticosteroids remain the mainstay of drug therapy. However, ~40% of patients do not respond to this treatment, and the mechanisms underlying the altered response to corticosteroids are not understood. The current study aimed to identify changes in hepatic protein expression associated with responsiveness to corticosteroids and prognosis in patients with AH. Patients with AH were enrolled based on the National Institute on Alcohol Abuse and Alcoholism inclusion criteria for acute AH and further confirmed by a diagnostic liver biopsy. Proteomic analysis was conducted on liver samples acquired from patients with AH grouped as nonresponders (AH-NR, n = 7) and responders (AH-R, n = 14) to corticosteroids, and nonalcohol-associated liver disease controls (n = 10). The definition of responders was based on the clinical prognostic model, the Lille Score, where a score < 0.45 classified patients as AH-R and a score > 0.45 as AH-NR. Primary outcomes used to assess steroid response were Lille Score (eg, improved liver function) and survival at 24 weeks. Reduced levels of the glucocorticoid receptor and its transcriptional co-activator, glucocorticoid modulatory element-binding protein 2, were observed in the hepatic proteome of AH-NR versus AH-R. The corticosteroid metabolizing enzyme, 11-beta-hydroxysteroid dehydrogenase 1, was increased in AH-NR versus AH-R along with elevated mitochondrial DNA repair enzymes, while several proteins of the heat shock pathway were reduced. Analysis of differentially expressed proteins in AH-NR who survived 24 weeks relative to AH-NR nonsurvivors revealed several protein expression changes, including increased levels of acute phase proteins, elevated coagulation factors, and reduced mast cell markers. This study identified hepatic proteomic changes that may predict responsiveness to corticosteroids and mortality in patients with AH.

59 BASIC BIOLOGICAL SCIENCES↗

Extension of Large Fire Emissions From Summer to Autumn and Its Drivers in the Western US

Abstract Burned areas in the western US have increased ten‐fold since 1980s, which are attributable to multiple factors, including increasing heat, changing precipitation patterns, and extended drought. To better understand how these factors contribute to large fire emissions (gridded monthly fire emissions >95th percentile of all the fire emissions in the western US; 0.009 Gg/month), we build a machine learning model to predict fire emissions (PM 2.5 ) over the western US at 0.25° resolution, interpreted using explainable artificial intelligence (XAI). From the predictor contributions derived from XAI, we conduct k‐means clustering analysis to identify four clusters of predictor variables representing different drivers of large fire emissions. The four clusters feature the contributions of fuel load (Cluster 1) and different levels of dryness (Cluster 2–4), controlled by fuel moisture, drought condition, and fire‐favorable large‐scale meteorological patterns featuring high temperature, high pressure, and low relative humidity. In the past two decades, large fire emissions peak in summer. However, large fire emissions increased significantly in September and October in 2010–2020 relative to 2000–2009, extending the peak large fire emissions from summer to autumn. The larger enhancements of large fire emissions during autumn compared to summer are contributed by decreased fuel moisture, along with more frequent concurrent fire‐favorable large‐scale meteorological patterns and drought. These results highlight fuel drying as a common driver supported by multiple drivers, such as warmer temperature and more frequent synoptic patterns favorable for fires, in increasing the autumn risk of large fire emissions across the western US.

54 ENVIRONMENTAL SCIENCES↗

Design and Construction of a High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory, together with Lawrence Berkeley National Laboratory, is building a new High Field Vertical Magnet Test Facility (HFVMTF) to be situated in the Magnet Test Facility at Fermilab. The HFVMTF is jointly funded by the US DOE Offices of Science, High Energy Physics, and Fusion Energy Sciences, and will serve as a superconducting cable test facility for both communities. The background magnetic field for test samples is 15 T and will be produced by a magnet provided by LBNL operating at 1.9 K in superfluid helium. The samples will be placed in the background magnetic field, cooled to between 4.5 K and a user-specified upper limit, and will be powered with a super-conducting transformer at up to 100 kA. Additionally, this facility will be used to test high-field superconducting magnet models and demonstrators, including hybrid magnets, produced by the US Magnet Development Program. Presently, the various tasks of the project are at different stages of execution, from conceptual to ready-for-construction designs. Here, this paper describes the parameters and design status of the pit construction, cryostat, heat exchanger, lambda plate, power system, and quench protection and monitoring systems of the facility.

43 PARTICLE ACCELERATORS↗

Thermal-Mechanical Elastic-Plastic and Ductile Failure Model Calibrations for 304L Stainless Steel Alloy

Numerical simulations of metallic structures undergoing rapid loading into the plastic range require material models that accurately represent the response. In general, the material response can be seen as having four interrelated parts: the baseline response under slow loading, the effect of strain rate, the conversion of plastic work into heat and the effect of temperature. In essence, the material behaves in a thermal-mechanical manner if the loading is fast enough so when heat is generated by plastic deformation it raises the temperature and therefore influences the mechanical response. In these cases, appropriate models that can capture the aspects listed above are necessary. The material of interest here is 304L stainless steel, and the objective of this work is to calibrate thermal-mechanical models: one for the constitutive behavior and another for failure. The work was accomplished by first designing and conducting a material test program to provide data for the calibration of the models. The test program included uniaxial tension tests conducted at room temperature, 150 and 300 C and at strain rates between 10 –4 and 10 3 1/s. It also included notched tension and shear-dominated compression hat tests specifically designed to calibrate the failure model. All test specimens were extracted from a single piece of plate to maintain consistency. The constitutive model adopted was a modular $J_2$ plasticity model with isotropic hardening that included rate and temperature dependence. A criterion for failure initiation based on a critical value of equivalent plastic strain fitted the failure data appropriately and was adopted. Possible ranges of the values of the parameters of the models were determined partially on historical data from calibrations of the same alloy from other lots and are given here. The calibration of the parameters of the models were based on finite element simulations of the various material tests using relatively ne meshes and hexahedral elements. When using the model in structural finite element calculations, however, element formulations and sizes different from those in the calibration are likely to be used. A brief investigation demonstrated that the failure initiation predictions can be particularly sensitive to the element selection and provided an initial guide to compensate for the effect of element size in a specific example.

36 MATERIALS SCIENCE↗

Optimizing Simulation Fidelity in Direct-Drive Inertial Confinement Fusion with Cassio

Recently, the National Ignition Facility (NIF) demonstrated that inertial confinement fusion (ICF) is capable to achieve thermonuclear (TN) ignition in the laboratory, making it a crucial method on the path to replicate the Sun’s power production mechanism on Earth. However, the physics governing the high-energy density environments is very complex and remains a challenge to fully understand and model. For example, dopants in the TN fuel are important diagnostic tools to extract the thermodynamic conditions of the plasma. However, if their concentration is chosen too high, they can significantly degrade the performance of an ICF capsule. In this study, we use the Los Alamos National Laboratory radiation-hydrodynamics code Cassio to model ICF implosions of capsules which contain deuterium fuel with high-Z dopants like Krypton and Argon from the high-Z campaign conducted 15 years ago. We focus on how chosen computational and physics parameters influence the implosion outcomes. By systematically changing the resolution of the computational mesh and the photon energies as well as modifying settings for the laser drive and TN fuel pre-heat effects, we assess the impact on experimentally measured performance metrics like neutron production from TN burn and x-ray emission during the implosion. Our results will help to improve the fidelity of simulations and guide future numerical studies and experimental designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Process intensification approach to enhancing heat and mass transfer: Radio frequency (RF) assisted drying of paper and board

Conventional multi-cylinder drying of paper and board typically relies on both conductive drying from steam-heated cylinders and convective drying, where heated air flows over the paper web surface. Conduction primarily contributes to heat transfer, while convection is the main driver of mass transfer. However, conventional drying systems are heavily dependent on steam, usually powered by fossil fuels, and are often energy-inefficient with high levels of waste. Additionally, these surface-driven processes result in a lower percentage of energy absorption compared to the energy supplied, leading to significant energy losses. To improve this long-standing process, an experimental system was developed to investigate a process intensification approach involving the integration of Radio Frequency (RF) heating, a volumetric electromagnetic technology, alongside traditional conduction and convection drying methods. This study also emphasizes the use of sensors to continuously monitor key parameters such as moisture content, supply system temperatures, sample temperatures, air flows, and drying rates in real-time. The effect of RF as an auxiliary energy source in localized environments at varying moisture levels was explored to optimize industrial drying systems, quantify potential improvements, and provide insights for future studies. Experimental results from trials combining RF with convection and with the base case alternating conduction-convection drying processes are presented. It is shown that RF is a viable process intensification approach for paper drying improving the drying rate and energy intensity at higher moisture contents. These findings offer valuable insights for process intensification and contribute to the process development, modeling, and simulation of advanced paper drying techniques.

42 ENGINEERING↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling of Supercritical CO2 Shell-and-Tube Heat Exchangers Under Extreme Conditions: Part II: Heat Exchanger Model

Abstract Heat exchangers play a critical role in supercritical CO2 Brayton cycles by providing necessary waste heat recovery. Supercritical CO2 thermal cycles potentially achieve higher energy density and thermal efficiency operating at elevated temperatures and pressures. Accurate and computationally efficient estimation of heat exchanger performance metrics at these conditions is important for the design and optimization of sCO2 systems and thermal cycles. In this paper (Part II), a computationally efficient and accurate numerical model is developed to predict the performance of shell-and-tube heat exchangers (STHXs). Highly accurate correlations reported in Part I of this study are utilized to improve the accuracy of performance predictions, and the concept of volume averaging is used to abstract the geometry and reduce computation time. The numerical model is validated by comparison with computational fluid dynamics (CFD) simulations and provides high accuracy and significantly lower computation time compared to existing numerical models. A preliminary optimization study is conducted and the advantage of using supercritical CO2 as a working fluid for energy systems is demonstrated.

Engineering↗

Evaluating the performance of WRF urban schemes and PBL schemes over Dallas-Fort Worth during a dry summer and a wet summer

This study evaluated the Weather Research and Forecasting (WRF) model sensitivity to different planetary boundary layer (PBL) schemes (the YSU and MYJ schemes) and urban schemes including the bulk scheme (BULK), single-layer urban canopy model (UCM), multi-layer building environment parameterization (BEP) model, and multi-layer building energy model (BEM). Daily reinitialization simulations were conducted over Dallas-Fort Worth during a dry summer month (July 2011) and a wet summer month (July 2015) with weaker (stronger) daytime (nocturnal) UHI in 2011 than 2015. All urban schemes overestimated the urban daytime 2m temperature in both summers, but BEP and BEM still reproduced the daytime urban cool island in dry summer. All urban schemes reproduced the nocturnal urban heat island, with BEP producing the weakest one due to its unrealistic urban cooling. BULK and UCM overestimated the urban canopy wind speed, while BEP and BEM underestimated it. The urban schemes showed prominent impact on daytime PBL profiles. UCM+MYJ showed a superior performance than other configurations. The relatively large (small) aspect ratio between building height and road width in UCM (BEM) was responsible for the overprediction (underprediction) of urban canopy temperature. The relatively low (high) building height in UCM (BEM) was responsible for the overprediction (underprediction) of urban canopy wind speed. Improving urban schemes and providing realistic urban parameters were critical for improving urban canopy simulation.

54 ENVIRONMENTAL SCIENCES↗

Experimental Study of Alfvén Wave Reflection from an Alfvén-speed Gradient Relevant to the Solar Coronal Holes

Abstract We report the first experimental detection of a reflected Alfvén wave from an Alfvén-speed gradient under conditions similar to those in coronal holes. The experiments were conducted in the Large Plasma Device at the University of California, Los Angeles. We present the experimentally measured dependence of the coefficient of reflection versus the wave inhomogeneity parameter, i.e., the ratio of the wavelength of the incident wave to the length scale of the gradient. Two-fluid simulations using the Gkeyll code qualitatively agree with and support the experimental findings. Our experimental results support models of wave heating that rely on wave reflection at low heights from a smooth Alfvén-speed gradient to drive turbulence.

79 ASTRONOMY AND ASTROPHYSICS↗

Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility

Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO 2 ) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO 2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO 2 -side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Furthemore, off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.

14 SOLAR ENERGY↗

Development of a Comprehensive Two-Phase Flow Database for the Validation of NEK-2P

Three-dimensional (3-D) two-phase Computational Fluid Dynamics (CFD) codes are emerging as a powerful and potentially practical tool for applications in which detailed local flow information is needed. However, two-phase flow models and associated closure relations are not well established for CFD applications, which is partly due to the lack of high-quality validation data. The main objective of this work is to develop a comprehensive database of two-phase flows that can be used to validate two-phase CFD codes such as NEK-2P. In this project, four advanced local measurement systems, including Particle Image Velocimetry and Planar Laser-Induced Fluorescence (PIV-PLIF), high-speed imaging, x-ray densitometry, and multi-sensor conductivity probe are employed to measure the local two-phase flow parameters of both gas and liquid phases. By combining these techniques, the local void fraction, bubble velocity, interfacial area concentration, bubble frequency, liquid velocity, turbulence intensity, etc., in various two-phase flow regimes can be obtained. These local measurement techniques are first used in a 25.4 mm circular pipe test section. Seven air-water two-phase flow conditions spanning the bubbly, slug, churn-turbulent, and annular flow regimes are measured in this facility. The obtained database contains the radial profiles of both gas- and liquid-phase parameters at three axial locations along the test section. The second facility used in this work contains a 30 mm × 10 mm rectangular test section, in which three two-phase flow and two single-phase flow conditions are measured. Two-dimensional distributions of local two-phase flow parameters in the cross-sectional plane are measured in this facility at three axial locations as well. A facility featuring a 3×3 electrically heated rod bundle is also designed and being constructed in this project. This facility is specially designed for optical measurements and is expected to provide high-quality boiling data in the future. Preliminary analyses have been performed for the data taken in the 25.4 mm circular pipe. Both center-peaked and wall-peaked void fraction profiles have been observed in the data depending on the two-phase flow conditions and/or developing lengths. The 1-D drift-flux model was evaluated with the newly obtained datasets, in which both gas- and liquid-phases data were directly measured. The distribution parameter model has been optimized based on a new void-profile classification method proposed in this study. The optimized drift-flux model shows a significant improvement in predicting both gas velocity and void fraction. The measured liquid-phase turbulence was used to benchmark Sato’s turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. In the bubbly flows tested that have low void fractions less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction. The Conjugate Heat Transfer (CHT) model was developed and implemented in NEK-2P. This model allows the coupled simulation of the solid domain and two-phase fluid domain, allowing the specification of realistic boundary conditions. The CHT implementation was verified first with non-boiling simulations. The predicted temperatures in the fluid domain were shown to be identical in simulations with or without the CHT model. The CHT model was then validated through simulations of three Becker benchmark CHF tests performed under both Dryout (DO) and Departure from Nucleate Boiling (DNB) conditions. Reasonably good agreement was obtained between calculated wall temperatures and corresponding experimental data.

42 ENGINEERING↗

Life Cycle Analysis of Natural Gas Supply Chain and End Use Applications in the United States

Natural gas (NG) plays a crucial role in current and future energy systems in the United States due to its abundance and affordability. In this study a life cycle analysis of the NG supply chain in the United States was conducted using Argonne's R&D GREET model, examining stages from recovery to distribution using reported field data processed and documented by National Energy Technology Laboratory. Supply chain emissions were evaluated across multiple spatial scales, including national average, overall regional production, region-to-region, and basin-to-region scenarios. The GHG intensity of the U.S. average NG supply chain was estimated at 10.3 kg CO 2 e/MMBtu (lower heating value), with a range across regions from 7.8 kg CO 2 e/MMBtu (Northeast) to 15.1 kg CO 2 e/MMBtu (Pacific). The analysis further assessed how upstream NG emissions influence the life cycle GHG emissions of key end-use applications, including electricity generation (0.044–0.086 kg CO 2 e/kWh from upstream NG in combined cycle facilities), hydrogen production (1.04–2.20 kg CO 2 e/kg H 2 for steam methane reforming [SMR] and 1.06–2.23 kg CO 2 e/kg for autothermal reforming [ATR]), and transit bus operation utilizing compressed natural gas fuel (0.19–0.37 kg CO 2 e/mile) and hydrogen fuel (0.12–0.25 kg CO 2 e/mile for hydrogen produced in SMR and ATR).

compression↗

Electromagnetic levitation containerless processing of metallic materials in microgravity: rapid solidification

Space levitation processing allows researchers to conduct benchmark tests in an effort to understand the physical phenomena involved in rapid solidification processing, including alloy thermodynamics, nucleation and growth, heat and mass transfer, solid/liquid interface dynamics, macro- and microstructural evolution, and defect formation. Supported by ground-based investigations, a major thrust is to develop and refine robust computational tools based on theoretical and applied approaches. This work is accomplished in conjunction with experiments designed for precise model validation with application to a broad range of industrial processes.

42 ENGINEERING↗

Thermal loading analysis of the ring injection dump for the Spallation Neutron Source facility

The ring injection dump (RID) is the largest beam dump in the Spallation Neutron Source facility at Oak Ridge National Laboratory and accepts a fraction of the beam from the ring that is not captured in the ring during injection. Thermo-fluid modeling of the RID components was performed during the initial design by using the software ANSYS CFX to characterize the power rating for the RID. From the calculations, the power rating was lowered from 200 kW to 150 kW, at 1.3 GeV beam energy due to concerns regarding the heating of the concrete structure. The Proton Power Upgrade project scope included reevaluating the power limit to the RID in anticipation that increasing it would provide more operational flexibility. The focus was on the shielding because it was the limiting factor, and data collected from thermocouples installed on the structure were used to benchmark the analysis. A three-stage process was adopted in the latest study. First, the already existing steady-state calculations were validated and extended with the latest Monte Carlo N-Particle source term calculations. Second, transient calculations were conducted to capture the dynamic state of the system in response to the energy dumped to the RID during the following operational period of the beam from 2005–2019 (14 years), and sensitivity analyses of crucial parameters were performed to benchmark the model with reasonable accuracy. Finally, an idealized transient cycle analysis was conducted with realistic duty factors to predict the temperature distribution at higher beam powers. Overall, the results confirmed the accuracy of the original steady state model but allowed the development of a new validated transient model with higher accuracy for future analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technoeconomic Analysis of the Electrochemically Mediated Amine Regeneration CO 2 Capture Process

The electrochemically mediated amine regeneration (EMAR) process presents an alternative route to the conventional thermal amine regeneration for carbon capture from a flue gas source. In this study, we conducted an economic analysis on the EMAR system for postcombustion CO2 capture from a 550 MWe power plant capturing 3.1 MtCO2 annually and from a mini steel mill with annual capture close to 170 ktCO2. We followed the recommendation of the National Energy Technology Laboratory (NETL) 2010 report to estimate the cost of CO2 avoided ([$/tCO2]). Detailed cost modeling of the electrochemical separation stage was conducted. This is integrated with the entire process flowsheet (e.g., including absorber, compressor, pumps, and other auxiliary equipment). Here, we identified the membrane cost as the dominant capital cost for the electrochemical separation train. At a membrane unit price of less than 10/m2, the CO2 capture cost can be reduced to below 50/tCO2 with optimized process conditions (e.g., desorption pressure and utilization of waste heat). Improvements in process design, cell construction, and solvent formulation may lead to additional reductions in the CO2 capture cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Approaching PetaVolts per Meter Plasmonics Using Structured Semiconductors

A newly uncovered class of plasmons in the strongly excited limit opens access to unprecedented Petavolts per meter electromagnetic fields with wide-ranging, transformative impact. Unlike conventional plasmons, such plasmons are constituted by non-perturbative, large-amplitude oscillations of the ultradense, delocalized free electron Fermi gas inherent in conductive media. Here structured semiconductors doped to have an appropriate conduction electron density are introduced to tune the properties of the Fermi gas for matched excitation of large-amplitude plasmons using readily available electron beams which enables immediate experimental validation. Specifically, an electrostatic, surface “crunch-in” plasmon is collisionlessly excited by the beam launched inside a tube. Strong excitation due to matching results in relativistic oscillations of the electron gas and unravels unique phenomena. Relativistically induced ballistic electron transport comes about due to relativistic multifold increase in the mean free path and also leads to unconventional heat deposition beyond Ohm’s law. This explains the absence of observed damage or solid-plasma formation in past experiments on conductive samples interacting with electron bunches shorter than 10-13 seconds. Furthermore, relativistic momentum leads to copious tunneling of electron gas across the surface, which then crunches inside the tube. Relativistic effects along with large, localized electron density variations underlying these modes necessitate kinetic approach to theoretical and computational modeling. Kinetic model presented here demonstrates experimental viability of observing tens of gigavolts per meter plasmonic fields excited by matching readily available electron beams to plasmons in semiconductors with 1018cm-3 free electron density, and paves the way for Petavolts per meter plasmonics.

42 ENGINEERING↗

Atomistic Simulations for Thermophysical Properties of Uranium-Containing Halide Molten Salts

Characterizing the thermophysical properties in both fuel and coolant salts are critical in modeling, developing, process optimizing and utilizing molten salt reactors (MSRs), as these properties directly relate to operation metrics and can inform on the selection of candidate salts. The demand for consistent, accurate and publicly available thermophysical property data has become more apparent in recent years as interests have increased from molten salt reactor developers. There are a number of challenges in experimentally measuring properties such as thermal conductivity, viscosity, density and heat capacity , which have led to sparse and often times conflicting data points or molten salts in general. Additionally, there are a number of hazards to consider when synthesizing, storing, using, treating and disposing of molten salts. With the advances in computational capabilities over the last 10 years, the use of atomistic simulations can be implemented to support these efforts. The primary objective of this work is characterize the thermophysical transport properties in a number of molten chloride salts, and in particular NaCl-UCl 3 using ab-initio molecular dynamic (AIMD) simulations. In this binary salt the UCl 3 acts as the primary fissile material and NaCl acts as a carrier salt due with its’ high solubility for actinides A number of studies on the thermophysical properties of NaCl-UCl 3 have been published but there is not a vast amount of viscosity data for this system. In 1975, Desyatnik, et al published a study reporting dynamic viscosities that were calculated from kinematic viscosity measurements, and using the coefficients provided the viscosity in a 70:30 NaCl:UCl 3 mixture is 2.29 cP and 2.88 for a 60:40 mixture. Termini et al. recently reported viscosities in the range of 2.75 – 3 cP for the 63:37 NaCl-UCl 3 mixture in the same temperature range using rolling ball viscosity measurements. Computational viscosity of a similar mixture (64:36) can be obtained from the work Andersson et al. using the reported diffusion coefficients, and the hydrodynamic radius from the pair-radial distribution functions (RDFs). Using Eq (1) (vida infra), the viscosity would be 2.50 cP at 1100K. This is not to say that these values are incorrect due to the varying reported values, but aims to highlight the necessity of this work. The data reported in this ongoing work are computations on a 64:36 mixture of NaCl-UCl 3 at 987K. This work is likely to be expanded into varying concentrations of this mixture along with the inclusion of other salt candidate mixtures.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗