Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Transfer Fluid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Skylab extravehicular mobility unit thermal simulator

The analytical methods, thermal model, and user's instructions for the Skylab Extravehicular Mobility Unit (SEMU) routine are presented. This digital computer program was developed for detailed thermal performance predictions of the SEMU on the NASA-JSC Univac 1108 computer system. It accounts for conductive, convective, and radiant heat transfer as well as fluid flow and special component characterization. The program provides thermal performance predictions for a 967 node thermal model in one thirty-sixth (1/36) of mission time when operated at a calculating interval of three minutes (mission time). The program has the operational flexibility to: (1) accept card or magnetic tape data input for the thermal model describing the SEMU structure, fluid systems, crewman and component performance, (2) accept card and/or magnetic tape input of internally generated heat and heat influx from the space environment, and (3) output tabular or plotted histories of temperature, flow rates, and other parameters describing system operating modes.

Hixon, C. W.↗

Development of an Efficient CFD Model for Nuclear Thermal Thrust Chamber Assembly Design

The objective of this effort is to develop an efficient and accurate computational methodology to predict both detailed thermo-fluid environments and global characteristics of the internal ballistics for a hypothetical solid-core nuclear thermal thrust chamber assembly (NTTCA). Several numerical and multi-physics thermo-fluid models, such as real fluid, chemically reacting, turbulence, conjugate heat transfer, porosity, and power generation, were incorporated into an unstructured-grid, pressure-based computational fluid dynamics solver as the underlying computational methodology. The numerical simulations of detailed thermo-fluid environment of a single flow element provide a mechanism to estimate the thermal stress and possible occurrence of the mid-section corrosion of the solid core. In addition, the numerical results of the detailed simulation were employed to fine tune the porosity model mimic the pressure drop and thermal load of the coolant flow through a single flow element. The use of the tuned porosity model enables an efficient simulation of the entire NTTCA system, and evaluating its performance during the design cycle.

Cheng, Gary↗

Phase Change Processes for Thermal Management Systems and Science Investigations

This white paper focuses on the scientific rationale and motivation for deploying phase change processes-based spacecraft thermal management systems for space missions [1,2]. Phase change processes need to be implemented in the design of various life support systems, sub-critical cryogenic and thermal control systems, taking advantage of the latent heat of phase change so as to significantly increase the heat transfer rate per unit fluid mass. Experimental data are critical to understanding gravitational effects on complex phase change processes using novel materials and working fluids. Experimental data can be acquired by either designing new testing platforms or performing experiments with simulant fluids on existing microgravity platforms. With the acquired data, theoretical flow physics models and numerical simulations can then be validated for use under long-duration microgravity conditions. The acquired data and validated models will enable the deployment of game-changing thermal management systems with remarkably improved efficiency and stability in heat acquisition, transport, and rejection for long-duration space missions.

Fluid mechanics↗

Heat transfer in rotating passages with smooth walls and radial outward flow

Experiments were conducted to determine the effects of rotation on heat transfer in turbine blade internal coolant passages. The experiments were conducted with a smooth wall, large-scale heat transfer model. The objective was to obtain the heat transfer data base required to develop heat transfer correlations and to assess computational fluid dynamic techniques for rotating coolant passages. An analysis of the governing equations showed that four parameters influence the heat transfer in rotating passages (coolant density ratio, Rossby number, Reynolds number, and radius ratio). These four parameters were varied over ranges that exceed the ranges of current open literature results, but that are typical of current and advanced gas turbine engine operating conditions. Rotation affected the heat transfer coefficients differently for different locations in the coolant passage. For example, heat transfer at some locations increased with rotation, but decreased and then increased again at other locations. Heat transfer coefficients varied by as much as a factor of five between the leading and trailing surfaces for the same test condition and streamwise location. Comparisons with previous results are presented.

Wagner, J. H.↗

Settling of two-way momentum and energy coupled particles subject to Boussinesq and non-Boussinesq heating

This work establishes a procedure to accurately compute heat transfer between an Eulerian fluid and Lagrangian point-particles. Recent work has focused on accurately computing momentum transfer between fluid and particles. The coupling term for momentum involves the undisturbed fluid velocity at the particle location which is not directly accessible in the simulation. Analogously, in the context of thermal coupling, the undisturbed fluid temperature at the particle location is not directly accessible in simulations and must be estimated. In this paper, we develop a scheme to accurately estimate the undisturbed fluid temperature of a point-particle exchanging thermal energy with a surrounding fluid. Furthermore, the temperature disturbance is correlated with the enhanced temperature curvature in the vicinity of the particle and is formally valid in the low heating, low convection limit. We conduct extensive verification of the correction procedure for a settling particle subject to radiation. This setup allows the simultaneous testing of thermal and momentum corrections. By considering equations of drag and Nusselt number extended to finite Péclet and Boussinesq numbers, we establish a large range over which the correction procedure can be applied.

42 ENGINEERING↗

Analysis of Laminar Convective Heat Transfer Over Structured Non-Wetting Surfaces

Structured non-wetting surfaces provide alternating no-slip and partial slip boundary conditions to the fluid flow which, in turn, affects the convective heat transfer performance over the surfaces. In this work, an analytical model is developed for the interfacial Nusselt number, the overall Nusselt number and a thermal hydraulic performance factor for fluid flow in a cylinder patterned with structured non-wetting surfaces, for the two cases of uniform wall heat flux and uniform wall temperature. In addition, by considering the stability of the Cassie state of wettability and its transition to the Wenzel state for flow over superhydrophobic surfaces, the present model overcomes certain limitations of the previously reported studies in the literature. Based on the analytical formulations and the stability constraints, the present paper provides optimum design maps for tailoring structured non-wetting surfaces for maximizing convective heat transfer and the combined thermal-hydraulic performance in applications. Use of the design maps on example cases is also discussed. It is shown that the use of structured non-wetting surfaces is most effective for low Reynolds numbers and/or small cylinder radius.

42 ENGINEERING↗

Extravehicular mobility unit thermal simulator

The analytical methods, thermal model, and user's instructions for the SIM bay extravehicular mobility unit (EMU) routine are presented. This digital computer program was developed for detailed thermal performance predictions of the crewman performing a command module extravehicular activity during transearth coast. It accounts for conductive, convective, and radiative heat transfer as well as fluid flow and associated flow control components. The program is a derivative of the Apollo lunar surface EMU digital simulator. It has the operational flexibility to accept card or magnetic tape for both the input data and program logic. Output can be tabular and/or plotted and the mission simulation can be stopped and restarted at the discretion of the user. The program was developed for the NASA-JSC Univac 1108 computer system and several of the capabilities represent utilization of unique features of that system. Analytical methods used in the computer routine are based on finite difference approximations to differential heat and mass balance equations which account for temperature or time dependent thermo-physical properties.

Hixon, C. W.↗

Unstructured mesh-based multi-physics reactor transient simulation with iMC code

In this study, we present a time-dependent Monte Carlo simulation result about a complex fuel-loaded light water reactor system with thermal-hydraulic feedback using the KAIST iMC code. The intra-pin temperature distribution is calculated based on Monte Carlo-tallied detailed power distribution and the finite element heat transfer method. The temperature effect of fuel, absorber, and coolant are adequately reflected into the dynamic response by the on-the-fly Doppler broadened cross-section correction. For the time-dependent Monte Carlo transport simulation, the predictor-corrector quasi-static Monte Carlo method is used for this study. We tested the coupled analysis framework with a 17-by-17 fuel assembly loaded with the centrally-shielded burnable absorber (CSBA) fuel element. The temperature feedback effect on the material cross-section and the moderator density incurred negative reactivity in response to the external positive reactivity insertion, showing the inherent stability of the reactor system. The pin-wise power and temperature change during the system transient are presented and discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

In-situ thermal transport measurement of flowing fluid using modulated photothermal radiometry

In situ thermal transport measurement of flowing fluid could be useful for the characterization and diagnosis of practical thermal systems such as fluid heat exchangers and thermal energy storage systems. Despite abundant reports on the ex-situ thermal conductivity measurement of stagnant fluids, a suitable technique for the thermal conductivity measurement of flowing fluid has been rarely reported. Here, this paper presents the thermal conductivity measurement of flowing fluid within a pipe using a non-contact modulated photothermal radiometry (MPR) technique, where the surface of the pipe is heated by an intensity-modulated laser and the heat diffuses into the fluid with suitable modulation frequency. We design a tube section with small wall thickness suitable for the MPR measurements to maximize the sensitivity of the thermal response to the fluid properties while minimizing the lateral heat spreading effect. Intrinsic thermal conductivity of different fluids was obtained within a proper range of frequency and flow velocity where the forced convection effect is negligible. The forced convection effect became prominent at high flowing velocity and at low modulation frequency, leading to higher effective thermal conductivity of the fluid. It is found that the intrinsic thermal conductivity could be obtained when the flow velocity is less than 100 mm/sec and Re D 1/2 Pr 1/3 < 100 for DI water and Xceltherm oil under the specified experimental conditions, where Re D is the Reynolds number and Pr is the Prandtl number.

42 ENGINEERING↗

Thermal Control System of the ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS)

The ECOSystem Spaceborne Thermal Radiometer Experiment on Space Station (ECOSTRESS) is a thermal infrared imaging multispectral scanner science mission. ECOSTRESS is designed and built by the NASA Jet Propulsion Laboratory and will be deployed on the International Space Station (ISS). ECOSTRESS will measure the water loss from growing leaves and the evaporation from the soil by measuring the temperature of plants and will gather data on the health of the agriculture system on Earth. The ISS orbit will allow ECOSTRESS to take observations at different times during each day over the seasons to provide coverage over the contiguous United States. The ECOSTRESS Thermal Control System (TCS) consists of a combination of active and passive components to maintain the ECOSTRESS components within the allowable flight temperature (AFT) limits. The active thermal control systems include mechanical cryocoolers, heaters and a single-phase pumped fluid loop for Instrument and Payload. The focal plane detector is cooled to 65K by a pair of mechanical cryocoolers and a third mechanical cryocooler cools an intermediate cold shield to 130K. The pumped fluid loop transfers the instrument waste heat to JAXA’s Japanese Exposed Module External Facility (JEM-EF) provided external fluid loop before rejection to space from the ISS radiators. The passive TCS includes multi-layer and single layer insulations, flexible thermal links and coatings on the radiometer. This paper describes the ECOSTRESS instrument TCS architecture, instrument thermal requirements and key design drivers, the top level thermal design and analysis approach, and reports preliminary test results.

Carroll, Brian↗

Numerical Analysis of Novel Plate Type Heat Exchanger with Oval-Twisted Channels

The novel heat exchanger (HX) designs implementing geometrical and surface modification combinations are expected to perform better than traditional HX technologies. Applied enhancement techniques seek to achieve (1) higher overall heat transfer performance, (2) increased compactness, and (3) simplified or comparable manufacturability. One innovative enhancement technique is to generate swirling flow vortices induced by channel or tube twisting. The turbulence generated by the twisted cross-section greatly enhances the heat transfer rate with minimal increases in pressure drop. Plate-type HXs and Printed Circuit Heat Exchangers (PCHXs) are compact designs that achieve high heat transfer rates per unit volume by utilizing several small channels, which maximizes the heat transfer surface area between the hot and cold fluids. Currently, advanced manufacturing technologies enable the design and fabrication of compact-type units with complicated channel geometries to achieve the highest performance and meet the compactness criteria of innovative HX technology. The proposed HX design concept combines the compactness of plate-type HXs and twisted channels, which provide additional turbulence and flow swirl enhancement. The plate-type oval-twisted HX (PTOTHX) is a crossflow configuration, with 16 short channels on one side (for hot fluid) and 8 long channels on the perpendicular side (for cold fluid). The inlet plenums have flow guide vanes to redirect flow and produce uniformity across the various flow paths. The compact size and purportedly improved heat transfer performance of the PTOTHX investigated herein prove its viability in various applications. Some notable potential nuclear applications of the PTOTHX include reactor core, spent fuel cooling, and residual heat dissipation. To establish a reference case, circular channels (PTCHX) are also considered in the present study for comparison with (PTOTHX). This paper aims to outline the numerical analysis procedures for determining the viability of the PTOTHX by comparing its heat transfer performance with the PTCHX units. The computational study used STAR-CCM+, a commercial computational fluid dynamics (CFD) code. Sensitivity analysis and model selection studies are conducted to determine the appropriate mesh density and turbulence model to provide the reported results. Numerical analyses comparing the Nusselt number (Nu) of the PTOTHX design with a comparable HX unit, including a circular cross-section and no twisting (PTCHX), show an overall heat transfer performance increase of 29-55% for balanced flow and 29-59% for imbalanced flow. Oval-cross-sectional twisted channels induce swirling flow vortices, enhancing the working fluid's convective heat transfer capabilities.

25 ENERGY STORAGE↗

A two-phase three-field modeling framework for heat pipe application in nuclear reactors

Heat pipes and two-phase thermosyphons are highly efficient heat transfer devices utilizing continuous evaporation and condensation of working fluid for two-phase heat transport in closed systems. Because of the nearly isothermal and fully passive phase-change heat transfer mechanism, heat pipes and thermosyphons have found many applications in nuclear engineering, space technologies, and other energy systems. High-temperature heat pipes are used in nuclear microreactors to remove fission power from the primary system and are coupled with power conversion systems or process heat applications. Modeling of the two-phase flow phenomena inside a heat pipe is essential to its design and safety analysis. In this study, a comprehensive one-dimensional two-phase three-field flow model has been developed for the analysis of heat pipes in normal operation conditions and transients. The conservation or field equations of mass, momentum, and energy were developed for the liquid film, vapor, and droplet. In addition, constitutive models or correlations were reviewed thoroughly and provided for the closure of the three-field equations. Specific constitutive equations regarding interfacial mass and heat transfer at two interfaces, namely film-gas interface and gas-droplet interface, were reviewed for droplet entrainment and deposition rates as well as film and droplet evaporation rates. Furthermore, mechanistic correlations of annular flow film thickness were recommended for the modeling of the thermosyphons without a wick as a critical constitutive correlation. Furthermore, experimental data needs from new experiments using a prototype working fluid or surrogate fluids for the model validation of high-temperature heat pipes in microreactors were recommended for future research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tempering kinetics during multilayer laser additive manufacturing of a ferritic steel

Grade 91 steel forms martensite during additive manufacturing and the extent of tempering of martensite significantly affects the mechanical properties of parts. Currently, there is a lack of quantitative understanding of the tempering kinetics for Grade 91 steel, and as a result, the effects of repeated thermal cycles on properties for different processing conditions cannot be determined. Here we evaluate the tempering kinetics by determining the constant terms in the Johnson Mehl Avrami kinetic equation from the tempering data available in the literature and the thermal cycles computed using a rigorously-tested heat and fluid flow model of multi-layer additive manufacturing. The raw tempering data are cleaned using a neural network to enhance accuracy. The lower layers experience repeating cycles of heating and cooling when the upper layers are added. As a result, the hardness is reduced owing to the tempering of martensite. In contrast, martensite formed in the upper layers is not tempered to the same extent and the hardness remains high. Therefore, the hardness of the part increases with the distance from the substrate. Variations in the heat input at different laser powers and scanning speeds significantly affect the extent of tempering. Finally, since the method used here can provide a quantitative understanding of the tempering of martensite and the spatial variation in hardness, it can be used to tailor the microstructure and hardness of heat treatable printed metallic parts.

36 MATERIALS SCIENCE↗

Heat pipes containing alkali metal working fluid

A technique for improving high temperature evaporation-condensation heat-transfer devices which have important and unique advantage in terrestrial and space energy processing is described. The device is in the form of a heat pipe comprising a sealed container or envelope which contains a capillary wick. The temperature of one end of the heat pipe is raised by the input of heat from an external heat source which is extremely hot and corrosive. A working fluid of a corrosive alkali metal, such as lithium, sodium, or potassium transfers this heat to a heat receiver remote from the heat source. The container and wick are fabricated from a superalloy containing a small percentage of a corrosion inhibiting or gettering element. Lanthanum, scandium, yttrium, thorium, and hafnium are utilized as the alloying metal.

Morris, J. F.↗

Initial study on cross-section generation requirements for a PBR equilibrium core

A Serpent model of the equilibrium core HTR-PM small modular nuclear reactor in China, was developed for use in cross-section preparation studies in order to guide methods development for the Griffin reactor multiphysics application. The model includes detailed isotopics for 10 distinct pebble burnup groups in 126 core zones with unique fuel and moderator temperatures obtained from a coupled neutronics-thermal-fluids equilibrium core calculation using Griffin-Pronghorn. A sensitivity study of the fuel and moderator temperatures for various core regions was performed with the MOOSE stochastic tools. The results show that the uncertainties are, not unexpectedly, dominated by the value of the fluid temperature and that the power level, heat transfer coefficient and effective conduction to neighboring pebbles and fluid constitute, at best, second order effects. The temperature uncertainty range varies from 28 K to 57 K between the core entry and exit planes, respectively, but these values are probably higher. We still have to quantify the significance of these uncertainties in the preparation of cross-sections in future work. In addition, we verified that the effective pebble approximation used in the PEBBED and V.S.O.P. computer codes works well for the preparation of region averaged cross-sections. Nevertheless, there are some discrepancies in the cross-sections when compared to the multi-pebble model, which could affect the prediction of peak values and the depletion calculation. We conclude that is highly desirable for future studies with Griffin to be able to handle both the 'effective' pebble approximation and the multi-pebble approach for various pebble burnup groups. This enables Griffin users with the flexibility to perform higher-fidelity studies. Finally, we initiated the preparation of cross-sections for various core regions from the full core Serpent reference model. We quantified the differences in 26 group cross-sections from infinite domain models versus the full core approach. These reference cross-sections will serve to verify the double heterogeneity, self-shielding, and spectrum-correction methods in Griffin. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An experimental study on gas-liquid phase fluid migration in hydrate-bearing sediments during hydrate dissociation

Natural gas hydrate production tests face problems such as severe sand blockage, poor gas-liquid phase separation, and significant land subsidence. This is because of the insufficient understanding of the complex phase transition and gas-liquid multi-phase fluid migration during hydrate dissociation. In hydrate-bearing sediment systems, hydrate phase transition couples with gas-liquid fluid migration. The phase transition causes changes in pore structure, which in turn modifies porous infiltration parameters and fluid flow capacity. Meanwhile, alterations in phase interfaces affect key parameters like surface tension and wettability. Gas-liquid fluid migration influences heat and mass transfer, thus affecting phase equilibrium and dissociation rates. To bridge the gap in describing gas-liquid fluid migration during hydrate dissociation in experiments, this research innovatively integrated an unsteady-state gas displacement by water and a quantitative hydrate dissociation process, independently developed a multi-phase seepage experimental system suitable for hydrate dissociation and determined the relationship between seepage parameters and hydrate saturation under different porosity. The results are as follows: a) Core samples with higher initial porosity show a greater recovery rate of fluid flow capacity. b) The retarding effect of multi-phase fluid has a more significant impact on the migration of the wetting phase fluid (water) than that of the non-wetting phase fluid (methane). c) During hydrate dissociation, the evolution of absolute permeability shows an “S-shaped” pattern, and the evolution of relative permeability shows a “wiring-harness” pattern. In conclusion, the findings can provide a theoretical basis for preventing geological disasters and for geotechnical engineering design during hydrate production.

58 GEOSCIENCES↗

Deployment of Traditional and Hybrid Machine Learning for Critical Heat Flux Prediction in the CTF Thermal-Hydraulics Code

Critical heat flux (CHF) marks the transition from nucleate to film boiling, where heat transfer to the working fluid can rapidly deteriorate. Accurate CHF prediction is essential for efficiency, safety, and preventing equipment damage, particularly in nuclear reactors. Although widely used, empirical correlations frequently exhibit discrepancies when compared to experimental data, limiting their reliability in diverse operational conditions. Traditional machine learning (ML) approaches have demonstrated potential for CHF prediction but often suffer from limited interpretability, data scarcity, and insufficient knowledge of physical principles. Hybrid model approaches, which combine data-driven ML with base models, mitigate these concerns by incorporating prior knowledge of the domain. This study integrates an externally trained purely data-driven ML model and two hybrid models (using the Biasi and Bowring CHF correlations) within the CTF subchannel code via a custom Fortran framework. Performance was evaluated using two validation cases: a subset of the Nuclear Regulatory Commission (NRC) CHF database and the Bennett dryout experiments. In both cases, the hybrid models demonstrated significantly lower error metrics compared to conventional empirical correlations, with the best models often reducing relative error by about 5 percentage points. The pure ML model achieved comparable accuracy, outperforming the hybrid Biasi model in the NRC test case (3.3% versus 5.5% relative error) but exhibiting slightly higher error against the hybrid Bowring model in the Bennett test case (7.7% versus 6.1%). Trend analysis of error parity indicated that ML-based models reduced the tendency for CHF overprediction, improving overall accuracy. These results demonstrate that ML-based CHF models can be effectively integrated into subchannel codes and could potentially increase performance compared to conventional methods.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗