Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Flux”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Anomalous Heat Budgets in the Interior Pacific Ocean on Seasonal- to -Timescales and Gyre Spacescales

This study quantifies uncertainties in closing the seasonal cycle of diabatic heat storage over the Pacific Ocean from 20 degrees S to 60 degrees N through the synthesis of World Ocean Circulation Experiment (WOCE) products over 7 years from 1993-1999. We utilize WOCE reanalysis products from the following sources: diabatic heat storage (DHS) from the Scripps Institution of Oceanography (SIO); near-surface geostrophic and Ekman currents from the Earth and Space Research (ESR); and air-sea heat fluxes from Comprehensive Ocean-Atmosphere Data Set (COADS), National Centers for Environmental Prediction (NCEP), and European Center for Mid-Range Weather Forecasts (ECMWF). We interpolate these products onto a common grid, allowing the seasonal cycle of DHS to be modeled for comparison with that observed. Everywhere latent heat flux residuals dominate sensible heat flux residuals and shortwave heat flux residuals dominate longwave heat flux residuals, both comparable in magnitude to the residual horizontal heat advection. We find the root-mean-square (RMS) of the differences between observed and model residual DHS tendencies to be less than 15 W per square meters everywhere except in the Kuroshio extension. Comparable COADS and NCEP products perform better than ECMWF products in the extra-tropics, while the NCEP product performs best in the tropics. Radiative and turbulent air-sea heat flux residuals computed from ship-born measurements perform better than those computed from satellite cloud and wind measurements. Since the RMS differences derive largely from biases in measured wind speed and cloud fraction, least-squares minimization is used to correct the residual Ekman heat advection and air-sea heat flux. Minimization reduces RMS differences less than 5 W per square meters except in the Kuroshio extension, suggesting how winds, clouds, and exchange coefficients in the NCEP, ECMWF, and ESR products can be improved.

White, Warren↗

Thermoelectric System Economics - The Apex: New Paradigms in Manufacturing and Interface Performance Relationships Driving System Cost Optimizations

Thermoelectric energy recovery systems require cost-optimized designs with high thermal and thermoelectric (TE) performance to surmount common commercialization barriers controlling the acceptance of thermoelectric generator (TEG) systems. Recent work has addressed this requirement with new analytic tools and paradigms that allow integrated TEG cost-performance analysis and optimization. New work herein has identified the existence of optimized TE element design (i.e., TE element length) for minimizing TEG cost and provides design guidelines associated with critical thermal and electrical contact resistance effects and TE manufacturing sensitivities. Once optimum hot-side heat flux criteria are satisfied, this work highlights the tradeoffs between interface resistance effects and manufacturing cost effects in determining optimum-cost TE element lengths, and then quantifies the increase in optimum-cost TE lengths as manufacturing costs become more sensitive to TE element lengths. Optimized TE element design criteria and key non-dimensional design parameters (i.e., [𝐶′′′LTE/𝐶′′], [TE/con], [con/(TE,aveLTE)]) driving the design are presented and explained showing the interdependencies between manufacturing cost parameters and thermal and electrical interface impacts on integrated TE cost-performance analysis and design. Comprehensive TEG system cost-performance relationships clearly demonstrate the two parameters that most greatly impact the TEG system cost are heat exchanger costs ($/(W/K)) and TE hot side heat flux. Reducing heat exhanger cost from $1/(W/K) to $0.5/(W/K) can decrease TEG system cost by $2/W to $4/W depending on TE hot side heat fluxes from 4-10 W/cm2. The impact of TE hot side heat flux on TEG system cost is larger; reducing TE system cost by factors of 2-4 as TE hot side heat flux increases from 4 W/cm2 to high levels around 18 W/cm2. The levels of thermal contact resistance and electrical contact resistance required to even approach the critical TEG system cost level of $1/W are characterized by con = 1.0 x 10-10 -m2 and r = 0.1, respectively. This not only lowers TEG costs, but it also makes the TEG system costs less sensitive to TE manufacturing dependences on TE element length. New design paradigms and relationships create holistic, integrated TE performance-cost models that enhance understanding of crucial interrelationships between component costs, TE design parameters and material properties, heat exchanger design parameters, interfacial heat flux, and now thermal and electrical interface effects in minimizing TEG system costs.

Hendricks, Terry J.↗

Boiling and cavitation caused by transient heat transfer in superfluid helium-4

Superfluid helium-4 (He II) has been widely utilized as a coolant in various scientific and engineering applications due to its superior heat transfer capability. An important parameter required in the design of many He II based cooling systems is the peak heat flux $q^*$, which refers to the threshold heat flux above which boiling spontaneously occurs in He II. Past experimental and numerical studies showed that $q^*$ increases when the heating time $t_h$ is reduced, which leads to an intuitive expectation that very high $q^*$ may be achievable at sufficiently small $t_h$. Knowledge on how $q^*$ actually behaves at small $t_h$ is important for applications such as laser ablation in He II. Furthermore we present a numerical study on the evolution of the thermodynamic state of the He II in front of a planar heater by solving the He II two-fluid equations of motion. For an applied heat flux, we determine the heating time beyond which the He II near the heater transits to the vapor phase. As such, a curve correlating $q^*$ and $t_h$ can be obtained, which nicely reproduces some relevant experimental data. Surprisingly, we find that there exists a critical peak heat flux $q^*_c$, above which boiling occurs nearly instantaneously regardless of $t_h$. We reveal that the boiling in this regime is essentially cavitation caused by the combined effects of the first-sound and the second-sound waves in He II. Based on this physical picture, an analytical model for $q^*_c$ is developed, which reproduces the simulated $q^*_c$ values at various He II bath temperatures and hydrostatic head pressures. This work represents a major progress in our understanding of transient heat transfer in He II.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of stationary filaments with resonant magnetic perturbations in NSTX

The application of resonant magnetic perturbations (RMPs) induces striated heat fluxes on the divertor plate in tokamaks. These striated heat fluxes were previously considered strike point splitting by the intersection between the divertor and predicted magnetic lobe structures. Recently, the existence of stationary 3D filaments has been observed for the first time in National Spherical Torus Experiment (NSTX) plasmas with toroidal mode number n = 3 RMPs. Magnetic field line tracing of these filaments from the midplane to the divertor is consistent with the quantity and the radial and toroidal location of striated heat fluxes observed on the divertor. This study suggests that divertor striated heat flux patterns are linked to these stationary filaments rather than to strike point splitting or magnetic lobe structures for NSTX. This finding will help guide future efforts to understand the heat flux striations in NSTX with RMPs in order to control and reduce the divertor peak heat flux.

RMPs↗

Ocean Surface Flux Algorithm Effects on Tropical Indo-Pacific Intraseasonal Precipitation

Surface latent heat fluxes help maintain tropical intraseasonal precipitation. We develop a latent heat flux diagnostic that depicts how latent heat fluxes vary with the near-surface specific humidity vertical gradient (Δq) and surface wind speed (|V|). Compared to fluxes estimated from |V| and Δq measured at tropical moorings and the Coupled Ocean Atmosphere Response Experiment 3.0 (COARE3.0) algorithm, tropical latent heat fluxes in the National Center for Atmospheric Research CEMS2 and Department of Energy E3SMv1 models are significantly overestimated at |V| and Δq extrema. Madden–Julian oscillation (MJO) sensitivity to surface flux algorithm is tested with offline and inline flux corrections. The offline correction adjusts model output fluxes toward mooring-estimated fluxes; the inline correction replaces the original bulk flux algorithm with the COARE3.0 algorithm in atmosphere-only simulations of each model. Both corrections indicate reduced latent heat flux feedback to intraseasonal precipitation, in better agreement with observations, suggesting that model-simulated fluxes are overly supportive for maintaining MJO convection.

54 ENVIRONMENTAL SCIENCES↗

MARS 2020 Backshell Radiative Heating Measurement and Shock Tube Verification

In February 2021, the Perseverance rover was brought to the surface of Mars by the Mars 2020 mission. A feature of the Mars 2020 capsule was instrumentation to measure its entry, descent and landing (EDL) with the so-called Mars EDL Instrumentation 2 (MEDLI2) [1]. The MEDLI2 introduced, among other things, backshell instrumentation, including a broadband radiometer. The radiometer was mounted on the leeside of the vehicle next to thermocouple plugs and a heat flux gauge. The data returned by the leeside MEDLI2 heat flux gauge is largely analogous to that measured by the COMARS gauge flown on the ExoMars Schiaparelli [2] entry in that it is measuring heat flux in an area that is entirely dominated by radiative heating. The COMARS measurement provided excellent validation of backshell radiative heating models for Mars entry, albeit at a limited number of points [3]. The MEDLI2 heat flux gauge measurement effectively confirmed the quality of the prediction, extended over the full trajectory, as will be presented in this paper. The MEDLI2 radiometer,however, was blocked by ablation products and suffered a loss of half of its signal. The second backshell heat flux gauge installed on the windside of the vehicle was also well predicted, although the heating had both radiative and convective contributions. It was desired to reproduce the conditions of the Mars 2020 entry via ground testing in the Electric Arc Shock Tube (EAST) at NASA Ames. Tests to verify stagnation line heating were previously reported in EAST, confirming the presence of shock layer radiation as the major discrepancy in heatshield temperature modelling [4]. Therefore, tests for stagnation line heating were not repeated. Instead, the shock tube informed bias method [5, 6] was used to identify test conditions that may produce similarity to streamlines that pass around the backside of the vehicle and are responsible for the radiation observed at the two heat flux gauge locations. This method was used to identify a range of velocities and densities in the shock tube that are relevant for confirming the radiative environment encountered. This paper reports the results obtained in the 10 cm diameter EAST shock tube, corresponding to later trajectory points at ambient pressures of 1.1-2.0 Torr and velocities from 1.2-3.5 km/s. The test series employed two primary diagnostics: emission spectroscopy and tunable diode laser absorption spectroscopy (TDLAS). The emission spectroscopy performed broadband measurements of the radiative emission of the 4.3 and 2.7 m bands of CO2 at flight similar conditions, obtaining both spectral and spatial data corresponding to the relaxation behind the shock front. The TDLAS measured the absorption of several lines of CO and CO2 and obtains species number densities and temperatures as a function of time behind the shock front. This paper will review highlights of this test series and analyses of the emission and absorption data. While the datasets generally show good agreement with predictions, a few discrepancies and items for additional investigation are identified and will be discussed

Brett A Cruden↗

The role of ETG modes in JET–ILW pedestals with varying levels of power and fuelling

Abstract We present the results of GENE gyrokinetic calculations based on a series of JET–ITER-like-wall (ILW) type I ELMy H-mode discharges operating with similar experimental inputs but at different levels of power and gas fuelling. We show that turbulence due to electron-temperature-gradient (ETGs) modes produces a significant amount of heat flux in four JET–ILW discharges, and, when combined with neoclassical simulations, is able to reproduce the experimental heat flux for the two low gas pulses. The simulations plausibly reproduce the high-gas heat fluxes as well, although power balance analysis is complicated by short ELM cycles. By independently varying the normalised temperature gradients ( ω T e ) and normalised density gradients ( ω n e ) around their experimental values, we demonstrate that it is the ratio of these two quantities η e = ω T e / ω n e that determines the location of the peak in the ETG growth rate and heat flux spectra. The heat flux increases rapidly as η e increases above the experimental point, suggesting that ETGs limit the temperature gradient in these pulses. When quantities are normalised using the minor radius, only increases in ω T e produce appreciable increases in the ETG growth rates, as well as the largest increases in turbulent heat flux which follow scalings similar to that of critical balance theory. However, when the heat flux is normalised to the electron gyro-Bohm heat flux using the temperature gradient scale length L T e , it follows a linear trend in correspondence with previous work by different authors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data efficiency assessment of generative adversarial networks in energy applications

This study investigates the data requirements of generative artificial intelligence (AI), particularly generative adversarial networks (GANs), for reliable data augmentation in energy applications. Generative AI, though seen as a solution to data limitations, requires substantial data to learn meaningful distributions—a challenge often overlooked. This study addresses the challenge through synthetic data generation for critical heat flux (CHF) and power grid demand, focusing on renewable and nuclear energy. Two variants of GAN employed are conditional GAN (cGAN) and Wasserstein GAN (wGAN). Our findings include the strong dependency of GAN on data size, with performance declining on smaller datasets and varying performance when generalizing to unseen experiments. Mass flux and heated length significantly influence CHF predictions. wGAN is more robust to feature exclusion, making it suitable for constrained synthetic data generation. In energy demand forecasting, wGAN performed well for solar, wind, and load predictions. Longer lookback hours and larger datasets improved predictions, especially for load power. Seasonal variations posed challenges, with wGAN achieving a relatively high error of Root Mean Squared Error (RMSE) of 0.32 for load power prediction, compared to RMSE of 0.07 under same-season conditions. Feature exclusions impacted cGAN the most, while wGAN showed greater robustness. This study concludes that, while generative AI is effective for data augmentation, it requires substantial data and careful training to generate realistic synthetic data and generalize to new experiments in engineering applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermocatalytic Heat Pipes for Geothermal Resource Recovery

Heat pipes are an important technology that allow orders of magnitude faster heat transfer than simple conduction. However, operating principles in heat pipes place fundamental bounds on their performance (critical heat flux and efficiency). Conventional heat pipe functionality is inherently tied to vaporization and condensation of the working fluid charged in the heat pipe. These fluids each have different operating temperature ranges based on the capillary, entrainment, sonic, and boiling limits of the heat pipe design. These limits, typically the capillary limit, dictate the maximum heat flux a heat pipe can carry, and most importantly for geothermal systems, the distance over which the pipes can operate (100 to 200 m maximum under optimum conditions). A thermocatalytic heat pipe breaks the inherent limitations of phase change thermo- and hydrodynamics and can transform heat pipe technology as a potentially more efficient means of extracting heat from a geothermal resource. The thermocatalytic heat pipe uses a working fluid to transport both sensible and chemical heat. An endothermic chemical reaction at depth removes heat from the reservoir and produces reactive intermediates, which are transported to the surface and used to run a reverse exothermic reaction that releases heat for use in power generation or other useful purposes. This technology offers two distinct advantages over conventional geothermal heat recovery technologies: (1) lower heat loss to the rock outside of the geothermal reservoir, and (2) higher heat transfer rates to the well field within the geothermal reservoir. Both advantages offer opportunity to reduce risks and lower costs of geothermal energy recovery. In this report, we discuss an initial effort to assess the efficacy and limitations of this technology for extracting heat from both porous/permeable and nominally impermeable geothermal reservoirs. Numerical simulation capabilities of the STOMP-GT code were enhanced to enable simulations of thermochemical heat pipes traversing geothermal reservoirs. An array of potential thermochemical reaction systems was evaluated and screened. Of these, an ethanol dehydration reaction was most promising in the vapor-liquid reaction set. A solid-phase dehydration reaction (CuSO4·5H2O) showed the highest reaction enthalpy per unit volume but would require development of a nonaqueous carrier fluid to implement it in a heat pipe. Subsurface reservoir simulations predicted long-term performance of the heat pipes for each geothermal reservoir type. The performance of U-shaped wells and coaxial wells was evaluated for a suite of reactions for both hydrothermal and hot dry rock reservoirs and was compared with a baseline case of simply pumping water through the wells. The heat pipe technology was additionally evaluated for an enhanced geothermal system (EGS) with an injection borehole, production borehole, and intervening hydraulically conductive fracture. All reservoir types showed significant improvement in heat recovered over a 20-year operating period ranging from a 1.8X increase for the hot dry rock case to more than 2.5X more energy recovered for the EGS case.

15 GEOTHERMAL ENERGY↗

Boiling Heat Transfer Mechanisms in Earth and Low Gravity: Boundary Condition and Heater Aspect Ratio Effects

Boiling is a complex phenomenon where hydrodynamics, heat transfer, mass transfer, and interfacial phenomena are tightly interwoven. An understanding of boiling and critical heat flux in microgravity environments is of importance to space based hardware and processes such as heat exchange, cryogenic fuel storage and transportation, electronic cooling, and material processing due to the large amounts of heat that can be removed with relatively little increase in temperature. Although research in this area has been performed in the past four decades, the mechanisms by which heat is removed from surfaces in microgravity are still unclear. Recently, time and space resolved heat transfer data were obtained in both earth and low gravity environments using an array of microheaters varying in size between 100 microns to 700 microns. These heaters were operated in both constant temperature as well as constant heat flux mode. Heat transfer under nucleating bubbles in earth gravity were directly measured using a microheater array with 100 m resolution operated in constant temperature mode with low and high subcooled bulk liquid along with images from below and from the side. The individual bubble departure diameter and energy transfer were larger with low subcooling but the departure frequency increased at high subcooling, resulting in higher overall heat transfer. The bubble growth for both subcoolings was primarily due to energy transfer from the superheated liquid layer relatively little was due to wall heat transfer during the bubble growth process. Oscillating bubbles and sliding bubbles were also observed in highly subcooled boiling. Transient conduction and/or microconvection was the dominant heat transfer mechanism in the above cases. A transient conduction model was developed and compared with the experimental data with good agreement. Data was also obtained with the heater array operated in a constant heat flux mode and measuring the temperature distribution across the array during boiling. The instantaneous heat transfer into the substrate was numerically determined and subtracted from the supplied heat to obtain the wall to liquid heat flux.

Kim, Jungho↗

Direct microstability optimization of stellarator devices

Turbulent transport is regarded as one of the key issues in magnetic confinement nuclear fusion, both for tokamaks and stellarators. Here, in this work, we show that a significant decrease in a microstability-based proxy, as opposed to a geometric one, for the turbulent heat flux, namely the quasilinear heat flux, can be obtained in an efficient manner by coupling stellarator optimization with linear gyrokinetic simulations. This is accomplished by computing the quasilinear heat flux at each step of the optimization process, as well as the deviation from quasisymmetry, and minimizing their sum, leading to a balance between neoclassical and the turbulent transport proxy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-Dimensional Simulations of Mantle Convection in Io

Io has very high surface heat flow and an abundance of volcanic activity, which are thought to be driven by nonuniform tidal heating in its interior. This nonuniform heat is transported to the base of the lithosphere by very vigorous convection in Io's silicate mantle, the form of which is presumably responsible for the distribution of surface features such as volcanoes and mountains. We here present three-dimensional spherical calculations of mantle convection in Io, in order to ascertain the likely form of this convection and the resulting distribution of heat flow at the surface and core-mantle boundary. Different models of tidal dissipation are considered: the endmember scenarios (identified by M. N. Ross and G. Schubert) of dissipation in the entire mantle, or dissipation in a thin (approximately 100-km-thick) asthenosphere, as well as the 'preferred' distribution of M. N. Ross et al. comprising 1/3 mantle and 2/3 asthenosphere heating. The thermal structure of Io's mantle and asthenosphere is found to be strongly dependent on tidal heating mode, as well as whether the mantle-asthenosphere boundary is permeable or impermeable. Results indicate a large-scale flow pattern dominated by the distribution of tidal heating, with superimposed small-scale asthenospheric instabilities that become more pronounced with increasing Rayleigh number. These small-scale instabilities spread out the surface heat flux, resulting in smaller heat flux variations with increasing Rayleigh number. Scaled to Io's Rayleigh number of O(10(exp 12)) variations of order a few percent are expected. This small but significant variation in surface heat flux may be compatible with the observed distributions of volcanic centers and mountains, which appear fairly uniform at first sight but display a discernible distribution when suitably processed. The observed distribution of volcanic centers is similar to the asthenosphere heating distribution, implying that most of the tidal heating in Io occurs in an asthenosphere.

Tackley, Paul J.↗

Characteristic of cryogenic hydrogen flames from high-aspect ratio nozzles

Unintentional leaks at hydrogen fueling stations have the potential to form hydrogen jet flames, which pose a risk to people and infrastructure. The heat flux from these jet flames are often used to develop separation distances between hydrogen components and buildings, lot-lines, etc. The heat flux and visible flame length is well understood for releases from round nozzles, but real unintended leaks would be expected to be from higher aspect-ratio cracks. Here, we measured the visible flame length and heat-flux characteristics of cryogenic hydrogen flames from high-aspect ratio nozzles. Heat flux measurements from 5 radiometers were used to assess the single-point vs the multi-point methods for interpretation of heat flux sensor data, finding the axial distance of the sensor for a single-point heat flux measurement to be important. We compare the flame length and heat flux data to flames of both cryogenic and compressed hydrogen from round nozzles. The aspect ratio of the release does not affect the flame length or heat flux significantly, for a given mass flow under the range of conditions studied. The engineering correlations presented in this work enable the prediction of flame length and heat flux which can be used to assess risk at hydrogen fueling stations with liquid hydrogen and develop science-based separation distances for these stations.

08 HYDROGEN↗

Simplified Methodology to Estimate the Maximum Liquid Helium (LHe) Cryostat Pressure from a Vacuum Jacket Failure

The aircraft-based Stratospheric Observatory for Infrared Astronomy (SOFIA) is a platform for multiple infrared astronomical observation experiments. These experiments carry sensors cooled to liquid helium temperatures. The liquid helium supply is contained in large (i.e., 10 liters or more) vacuum-insulated dewars. Should the dewar vacuum insulation fail, the inrushing air will condense and freeze on the dewar wall, resulting in a large heat flux on the dewar's contents. The heat flux results in a rise in pressure and the actuation of the dewar pressure relief system. A previous NASA Engineering and Safety Center (NESC) assessment provided recommendations for the wall heat flux that would be expected from a loss of vacuum and detailed an appropriate method to use in calculating the maximum pressure that would occur in a loss of vacuum event. This method involved building a detailed supercritical helium compressible flow thermal/fluid model of the vent stack and exercising the model over the appropriate range of parameters. The experimenters designing science instruments for SOFIA are not experts in compressible supercritical flows and do not generally have access to the thermal/fluid modeling packages that are required to build detailed models of the vent stacks. Therefore, the SOFIA Program engaged the NESC to develop a simplified methodology to estimate the maximum pressure in a liquid helium dewar after the loss of vacuum insulation. The method would allow the university-based science instrument development teams to conservatively determine the cryostat's vent neck sizing during preliminary design of new SOFIA Science Instruments. This report details the development of the simplified method, the method itself, and the limits of its applicability. The simplified methodology provides an estimate of the dewar pressure after a loss of vacuum insulation that can be used for the initial design of the liquid helium dewar vent stacks. However, since it is not an exact tool, final verification of the dewar pressure vessel design requires a complete, detailed real fluid compressible flow model of the vent stack. The wall heat flux resulting from a loss of vacuum insulation increases the dewar pressure, which actuates the pressure relief mechanism and results in high-speed flow through the dewar vent stack. At high pressures, the flow can be choked at the vent stack inlet, at the exit, or at an intermediate transition or restriction. During previous SOFIA analyses, it was observed that there was generally a readily identifiable section of the vent stack that would limit the flow – e.g., a small diameter entrance or an orifice. It was also found that when the supercritical helium was approximated as an ideal gas at the dewar condition, the calculated mass flow rate based on choking at the limiting entrance or transition was less than the mass flow rate calculated using the detailed real fluid model2. Using this lower mass flow rate would yield a conservative prediction of the dewar’s wall heat flux capability. The simplified method of the current work was developed by building on this observation.

Ungar, Eugene K.↗

Regulation of the solar wind electron heat fluxfrom 1 to 5 AU: Ulysses observations

In this study we use observations from the three-dimensional electron spectrometer and magnetometer aboard the Ulysses spacecraft to examine the solar wind electron heat flux from 1.2 to 5.4 AU in the ecliptic plane. Throughout Ulusses' transit to 5.4 AU, the electron heat flux decreases more rapidly (approximately R(exp -30)) than simple collisionless expansion along the local magnetic field and is smaller than expected for a thermal gradient heat flux, q(sub parallel e) (r) = - Kappa(sub parallel) del(sub parallel) T(sub e)(r). The radial gradients and magnitudes expected for a number of electron heat flux regulatory mechanisms are examined and compared to the observations. The best agreement is found for heat flux regulation by the whistler heat flux instability. The upper bound and radial scaling for the electron heat flux predicted for the whistler heat flux instability are consistent with the observations.

Scime, Earl E.↗

A direct numerical simulation study for confined non-isothermal jet impingement at moderate nozzle-to-plate distances: Capturing jet-to-ambient density effects

A direct numerical simulation (DNS) campaign is deployed for a series of confined downward oriented, non-isothermal turbulent impinging jet configurations. A baseline Reynolds number of 9960 is obtained through a precursor DNS pipe flow simulation (Re τ = 505). Three jet temperature configurations (confinement height to nozzle diameter of three) enter a cylindrical domain that share ambient and impingement plate temperatures (298.15 K). The range of jet temperatures are crafted such that the ratio of inlet to ambient density varies from unity to 0.52, showcasing the effect of density disparity on flow characteristics such as core collapse, radial mixing of momentum and energy, near-wall stagnation behavior, wall-jet profiles, and large-scale vortical structures. Surface quantities provided include mean radial heat flux and wall-shear stress profiles, and heat flux histograms at select radial stations. Results showcase increased radial normal stresses for higher temperature jets that support increased mixing, resulting in large-scale recirculation structures that are smaller, while retaining similar normalized radial wall profiles for shear stress, heat flux and pressure. Furthermore, radial plots for wall shear stress and Nusselt number showcase strong radial decay as compared to previous configurations that share similar jet and ambient temperatures. For the 373.15 K case, a Gaussian-like histogram for heat fluxes at the impingement plate transitions to a log-normal profile as radial distances increase. In contrast, the 573.15 K configuration displays a bi-modal heat flux characteristic at the impingement plate, and in similar manner to the moderate temperature counterpart, transitions to a log-normal profile at larger radial distances.

33 ADVANCED PROPULSION SYSTEMS↗

Validation of Supersonic Film Cooling Modeling for Liquid Rocket Engine Applications

Topics include: upper stage engine key requirements and design drivers; Calspan "stage 1" results, He slot injection into hypersonic flow (air); test articles for shock generator diagram, slot injector details, and instrumentation positions; test conditions; modeling approach; 2-d grid used for film cooling simulations of test article; heat flux profiles from 2-d flat plate simulations (run #4); heat flux profiles from 2-d backward facing step simulations (run #43); isometric sketch of single coolant nozzle, and x-z grid of half-nozzle domain; comparison of 2-d and 3-d simulations of coolant nozzles (run #45); flowfield properties along coolant nozzle centerline (run #45); comparison of 3-d CFD nozzle flow calculations with experimental data; nozzle exit plane reduced to linear profile for use in 2-d film-cooling simulations (run #45); synthetic Schlieren image of coolant injection region (run #45); axial velocity profiles from 2-d film-cooling simulation (run #45); coolant mass fraction profiles from 2-d film-cooling simulation (run #45); heat flux profiles from 2-d film cooling simulations (run #45); heat flux profiles from 2-d film cooling simulations (runs #47, #45, and #47); 3-d grid used for film cooling simulations of test article; heat flux contours from 3-d film-cooling simulation (run #45); and heat flux profiles from 3-d and 2-d film cooling simulations (runs #44, #46, and #47).

Morris, Christopher I.↗

Daytime convective development over land: the role of surface forcing

Water availability at the Earth surface determines the portioning of the surface heat flux into its sensible and latent components, that is, the surface heat flux Bowen ratio. The two components affect differently the surface buoyancy flux and thus the development and growth of the convective boundary layer. As a result, the Bowen ratio has a strong impact on the daytime dry and moist convection development over land. Here, we use two canonical modeling test cases, one for the shallow convection and one for the shallow-to-deep convection transition, to document the impact of the surface Bowen ratio on daytime convection development. A simple approach is used where results from simulations featuring the original setup are contrasted with simulations where surface sensible heat flux takes on values of the latent heat flux and vice versa. Such a change illustrates the key impact of the surface water availability without changing the total surface heat flux. Because of the larger surface buoyancy flux, simulations with the reversed surface heat fluxes feature faster deepening of the convective boundary layer and wider clouds once moist convection develops. Mean cloud base width of cumulus clouds increases with the boundary layer depth. For shallow-to-deep convection transition, comparison of simulations with the observed large-scale flow that feature substantial lower-tropospheric shear with simulations with no mean horizontal flow suggests that the organization of convective circulations within the boundary layer strongly affects initial size and organization of shallow convection, as well as the subsequent width increase once convection deepens and eventually transitions to deep precipitating convection. A simple explanation is provided of why deeper well-mixed convective subcloud layer results in wider clouds. The key is the larger width of boundary layer coherent updraft structures when the mixed layer is deeper.

54 ENVIRONMENTAL SCIENCES↗