SEARCH · Engineering Papers
Results for “Hardware in the loop”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Ultra-Compact High Efficiency Multi-Level Gan-Based PV Inverter
This project developed the key technology for a scalable, high-density photovoltaic (PV) inverter, based on gallium-nitride (GaN) power semiconductors, and advanced digital control. Specifically, we explored the feasibility of a flying-capacitor multi-level inverter for 1.5 kV PV installations, through the development of hardware prototypes utilizing low-inductance commutation loop designs, robust digital control and signaling, and low-cost heatsink integration.
Army-NASA aircrew/aircraft integration program: Phase 4 A(3)I Man-Machine Integration Design and Analysis System (MIDAS) software detailed design document
The Man-Machine Integration Design and Analysis System (MIDAS) is an integrated suite of software components that constitutes a prototype workstation to aid designers in applying human factors principles to the design of complex human-machine systems. MIDAS is intended to be used at the very early stages of conceptual design to provide an environment wherein designers can use computational representations of the crew station and operator, instead of hardware simulators and man-in-the-loop studies, to discover problems and ask 'what if' questions regarding the projected mission, equipment, and environment. This document is the Software Product Specification for MIDAS. Introductory descriptions of the processing requirements, hardware/software environment, structure, I/O, and control are given in the main body of the document for the overall MIDAS system, with detailed discussion of the individual modules included in Annexes A-J.
Compiling global name-space parallel loops for distributed execution
Distributed memory machines do not provide hardware support for a global address space. Thus programmers are forced to partition the data across the memories of the architecture and use explicit message passing to communicate data between processors. The compiler support required to allow programmers to express their algorithms using a global name-space is examined. A general method is presented for analysis of a high level source program and its translation into a set of independently executing tasks communicating via messages. If the compiler has enough information, this translation can be carried out at compile time. Otherwise, run-time code is generated to implement the required data movement. The analysis required in both situations is described and the performance of the generated code on the Intel iPSC/2 is presented.
Current results from a Rover Science Data Analysis System
In this paper, we provide a brief overview of the OASIS system, and then describe our recent successes in integrating with and using rover hardware. OASIS currently works in a closed loop fashion with onboard control software (e.g., navigation and vision) and has the ability to autonomously perform the following sequence of steps: analyze gray scale images to find rocks, extract the properties of the rocks, identify rocks of interest, retask the rover to take additional imagery of the identified target and then allow the rover to continue on its original mission. We also describe the early 2004 ground test validation of specific OASIS components on selected Mars Exploration Rover (MER) images. These components include the rockfinding algorithm, RockIT, and the rock size feature extraction code. Our team also developed the RockIT GUI, an interface that allows users to easily visualize and modify the rock-finder results. This interface has allowed us to conduct preliminary testing and validation of the rockfinder's performance.
An Environmental Impact Assessment of Perfluorocarbon Thermal Working Fluid Use On Board Crewed Spacecraft
The design and operation of crewed spacecraft requires identifying and evaluating chemical compounds that may present reactivity and compatibility risks with the environmental control and life support (ECLS) system. Such risks must be understood so that appropriate design and operational controls, including specifying containment levels, can be instituted or an appropriate substitute material selected. Operational experience acquired during the International Space Station (ISS) program has found that understanding ECLS system and environmental impact presented by thermal control system working fluids is imperative to safely operating any crewed space exploration vehicle. Perfluorocarbon fluids are used as working fluids in thermal control fluid loops on board the ISS. Also, payload hardware developers have identified perfluorocarbon fluids as preferred thermal control working fluids. Interest in using perfluorocarbon fluids as thermal control system working fluids for future crewed space vehicles and outposts is high. Potential hazards associated with perfluorocarbon fluids are discussed with specific attention given to engineering assessment of ECLS system compatibility, compatibility testing results, and spacecraft environmental impact. Considerations for perfluorocarbon fluid use on crewed spacecraft and outposts are summarized.
Optimal Force Control of Vibro-Impact Systems for Autonomous Drilling Applications
The need to maintain optimal energy efficiency is critical during the drilling operations performed on future and current planetary rover missions (see figure). Specifically, this innovation seeks to solve the following problem. Given a spring-loaded percussive drill driven by a voice-coil motor, one needs to determine the optimal input voltage waveform (periodic function) and the optimal hammering period that minimizes the dissipated energy, while ensuring that the hammer-to-rock impacts are made with sufficient (user-defined) impact velocity (or impact energy). To solve this problem, it was first observed that when voice-coil-actuated percussive drills are driven at high power, it is of paramount importance to ensure that the electrical current of the device remains in phase with the velocity of the hammer. Otherwise, negative work is performed and the drill experiences a loss of performance (i.e., reduced impact energy) and an increase in Joule heating (i.e., reduction in energy efficiency). This observation has motivated many drilling products to incorporate the standard bang-bang control approach for driving their percussive drills. However, the bang-bang control approach is significantly less efficient than the optimal energy-efficient control approach solved herein. To obtain this solution, the standard tools of classical optimal control theory were applied. It is worth noting that these tools inherently require the solution of a two-point boundary value problem (TPBVP), i.e., a system of differential equations where half the equations have unknown boundary conditions. Typically, the TPBVP is impossible to solve analytically for high-dimensional dynamic systems. However, for the case of the spring-loaded vibro-impactor, this approach yields the exact optimal control solution as the sum of four analytic functions whose coefficients are determined using a simple, easy-to-implement algorithm. Once the optimal control waveform is determined, it can be used optimally in the context of both open-loop and closed-loop control modes (using standard realtime control hardware).
EMU Ventilation Loop Simulation and Assessment of Contamination of the EMU Sublimator Hydrophilic Coating
Controlling moisture is a critical function performed in the space suit during extra vehicular activity (EVA) missions. Currently, this function is carried out by a sublimator, which is coated with a hydrophilic material. Tests have shown that siloxane compounds can off gas from the helmet absorption pad extension (HAP-E) and helmet absorption band (HAB) when they are at elevated temperatures and initial testing indicated that siloxanes could damage the hydrophilic coating. Therefore, more representative testing was needed. Important test considerations were source and destination kinetics, system geometries, scrubbing efficacy by the activated charcoal from the Metox canister, and other benefits that derive from active condensation occurring on the hydrophilic coating during exposure. A ventilation loop that was originally constructed to test hardware for control of CO2 and trace contaminants under EVA conditions was modified to conduct the siloxane off gassing tests. A vacuum compatible acrylic chamber was installed to simulate the suit volume. A steel beaker located in the chamber contained the HAP-E and HAB materials and was heated with two band heaters. The flow exiting the chamber passed through a LiOH cannister, which contained carbon beds to simulate their function in the Metox. The flow then was directed into a smaller volume that contained a coupon, which was coated with the hydrophilic material and was maintained at 10°C (50°F). Moisture was injected upstream of the suit volume simulator to maintain the dew point between 12.7°C (55°F) and 18.3°C (65°F). The pressure was controlled to between 3.8 and 4.4 psia, and the flow was held at 6 acfm. The system was run for an equivalent of 25 ten-hour EVAs, where the HAP-E/HAB materials were changed out after each EVA. The effect of the potential off gassing on the coupon was measured after each EVA period.
Intern Poster Session 08/13: Autonomous Nuclear Robotics: Applications in nuclear waste inspection and hot cell experiments
The nuclear industry is experiencing renewed interest in autonomous robotics, yet most deployed systems remain teleoperated with limited autonomy. This work presents two contributions toward fully autonomous nuclear robotic systems: autonomous waste inspection at the Hanford Site and an autonomous hot cell laboratory framework. Inspections of Hanford's underground waste storage tanks are performed manually at significant cost and personnel exposure. We developed a reinforcement-learning (RL) training pipeline for a custom-built inspection arm. In parallel, we are designing an autonomous laboratory framework for post-irradiation examination in hot cells at the Specimen Preparation Laboratory (SPL) that integrates computer vision, task and motion planning, hardware execution, and operator-in-the-loop control. These systems demonstrate a path toward safer, more efficient nuclear operations by reducing human exposure while maintaining rigorous human oversight at critical decision points.
Exploration Extravehicular Mobility Unit (xEMU) Chamber B Thermal Vacuum “Suit 2” Pressure Garment System Hardware and Test Design
NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation space suit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test hardware design and test methodology for the “Suit 2” Pressure Garment System (PGS) test article. The uncrewed “Suit 2” PGS test article consisted of a full PGS assembly with simulated Portable Life Support System (PLSS) functionality provided by test equipment, including a ventilation loop and two distinct thermal control loops. This paper will discuss in depth the test hardware design, including internal suit thermal boundary simulation, sensor quantity and placement, test support equipment rigs for gas flow, water flow, and power. Custom hardware designed to add additional penetrations to the suit or provide additional interfaces for sensors will also be discussed. This paper will also address the assembly and integration sequence for the test article. In addition to test hardware design, this paper will provide insights into the test methodology for this test article, including a discussion of thermal steady-state testing, simultaneous dual suit thermal vacuum testing, and hazard mitigation and controls.
Development of the engineering design integration (EDIN) system: A computer aided design development
The EDIN (Engineering Design Integration) System which provides a collection of hardware and software, enabling the engineer to perform man-in-the-loop interactive evaluation of aerospace vehicle concepts, was considered. Study efforts were concentrated in the following areas: (1) integration of hardware with the Univac Exec 8 System; (2) development of interactive software for the EDIN System; (3) upgrading of the EDIN technology module library to an interactive status; (4) verification of the soundness of the developing EDIN System; (5) support of NASA in design analysis studies using the EDIN System; (6) provide training and documentation in the use of the EDIN System; and (7) provide an implementation plan for the next phase of development and recommendations for meeting long range objectives.
Design and Certification of the Extravehicular Activity Mobility Unit (EMU) Water Processing Jumper
The Extravehicular Mobility Units (EMUs) onboard the International Space Station (ISS) experienced a failure due to cooling water contamination from biomass and corrosion byproducts forming solids around the EMU pump rotor. The coolant had no biocide and a low pH which induced biofilm growth and corrosion precipitates, respectively. NASA JSC was tasked with building hardware to clean the ionic, organic, and particulate load from the EMU coolant loop before and after Extravehicular Activity (EVAs). Based on a return sample of the EMU coolant loop, the chemical load was well understood, but there was not sufficient volume of the returned sample to analyze particulates. Through work with EMU specialists, chemists, (EVA) Mission Operations Directorate (MOD) representation, safety and mission assurance, astronaut crew, and team engineers, requirements were developed for the EMU Water Processing hardware (sometimes referred to as the Airlock Coolant Loop Recovery [A/L CLR] system). Those requirements ranged from the operable level of ionic, organic, and particulate load, interfaces to the EMU, maximum cycle time, operating pressure drop, flow rate, and temperature, leakage rates, and biocide levels for storage. Design work began in February 2005 and certification was completed in April 2005 to support a return to flight launch date of May 12, 2005. This paper will discuss the details of the design and certification of the EMU Water Processing hardware and its components
A comparison of Manchester symbol tracking loops for block 5 applications
The linearized tracking errors of three Manchester (biphase coded) symbol tracking loops are compared to determine which is appropriate for Block 5 receiver applications. The first is a nonreturn to zero (NRZ) symbol synchronizer loop operating at twice the symbol rate (NRZ x 2) so that it operates on half symbols. The second near optimally processes the mid-symbol transitions and ignores the between symbol transitions. In the third configuration, the first two approaches are combined as a hybrid to produce the best performance. Although this hybrid loop is the best at low symbol signal to noise ratios (SNRs), it has about the same performance as the NRZ x 2 loop at higher SNRs (greater than 0-dB E sub s/N sub 0). Based on this analysis, it is tentatively recommended that the hybrid loop be implemented for Manchester data in the Block 5 receiver. However, the high data rate case and the hardware implications of each implementation must be understood and analyzed before the hybrid loop is recommended unconditionally.
Piloted Full-Motion Simulation with Simulink®
A recent experiment at NASA Ames Research Center’s Vertical Motion Simulator (VMS) successfully combined a real-time, human in-the-loop architecture with the flexibility of operating in the Simulink® graphical model-based engineering environment. The VMS is a large amplitude flight simulator designed to be adaptable to provide rapid integration and development of a wide variety of vehicles and support diverse aeronautical investigations. Math models are often programmed in Simulink. Typically, to run Simulink models in real time, they are converted to C code. However, the conversion and integration process can be time consuming and cumbersome. Thus, the VMS facility capabilities were expanded to allow a Simulink vehicle math model to run in the MathWorks’ MATLAB environment during a piloted full-motion simulation experiment. The MATLAB Simulink based approach to driving the VMS was found to decrease development time by allowing quick integration of math model changes and providing the ability to run the same version of the model on researcher’s desktop computers. This accomplishment demonstrated that the development ease of the graphical Simulink environment could be retained, while working within the real-time environment of the VMS architecture and maintaining the unique flexibility of the VMS.
Multi-machine validation of plasma initiation modelling and prospects for future devices: Predicting plasma initiation using only hardware design and control room input data
This paper reports on the generic prediction capability of full electromagnetic plasma initiation modelling with DYON, which was carried out for the first time in fusion research by the joint modelling of the International Tokamak Physics Activity—Integrating Operation Scenario group. The following devices were included in the experiment database: VEST (spherical torus, copper coils, Stainless steel wall, R/a = 0.3 m/0.2 m, V v = 3.7 m 3 ), MAST-U (spherical torus, copper coils, C wall, R/a = 0.7 m/0.5 m, V v = 55 m 3 ), EAST (conventional tokamak, superconducting coils, metallic wall, R/a = 1.85 m/0.5 m, V v = 38 m 3 ), DIII-D (conventional tokamak, copper coils, C wall, R/a = 1.67 m/0.65 m, V v = 35 m 3 ), and KSTAR (conventional tokamak, superconducting coils, C wall, R/a = 1.8 m/0.5 m, V v = 55 m 3 ). Despite the different hardware features of the devices, the required operating spaces of the loop voltage induction and prefill gas pressure for inductive plasma initiation in each device were successfully reproduced by the predictive simulations with DYON using only the individual hardware design and the control room input data for each discharge. This successful validation across multiple machines demonstrates that the full electromagnetic DYON modelling can capture the essential physics of inductive plasma initiation. The simulation settings commonly employed for all modelling and the modifications necessary to account for the discrepancies between individual devices are reported. Predictions for ITER based on the multi-machine validation indicate that a wide range of prefill gas pressures exists for the Townsend breakdown and the plasma burn-through (0.01–1.5 mPa).
A dynamic motion simulator for future European docking systems
Europe's first confrontation with docking in space will require extensive testing to verify design and performance and to qualify hardware. For this purpose, a Docking Dynamics Test Facility (DDTF) was developed. It allows reproduction on the ground of the same impact loads and relative motion dynamics which would occur in space during docking. It uses a 9 degree of freedom, servo-motion system, controlled by a real time computer, which simulates the docking spacecraft in a zero-g environment. The test technique involves and active loop based on six axis force and torque detection, a mathematical simulation of individual spacecraft dynamics, and a 9 degree of freedom servomotion of which 3 DOFs allow extension of the kinematic range to 5 m. The configuration was checked out by closed loop tests involving spacecraft control models and real sensor hardware. The test facility at present has an extensive configuration that allows evaluation of both proximity control and docking systems. It provides a versatile tool to verify system design, hardware items and performance capabilities in the ongoing HERMES and COLUMBUS programs. The test system is described and its capabilities are summarized.
Auxiliary Payload Power System thermal control
The Auxiliary Payload Power System (APPS) provides supplementary power and cooling to Space Processing Application (SPA) experiments to be mounted in the APPS and the Spacelab in the Shuttle Payload Bay. SPA experiment operations are planned for early Shuttle flights. This paper presents thermal control study results for preliminary analysis and design definition of the APPS. A 100/sq m, three-wing, pumped-fluid, deployable radiator with separate APPS equipment and SPA experiments coolant loops was selected as the baseline. The system is capable of rejecting the heat (approximately 26 kw) associated with the production and consumption of approximately 16 kw of electrical power produced by the APPS fuel cells for a worst case radiator orientation. For the most favorable orientation, the heat rejection and power capability approach 38 and 24 kw, respectively. Alternate approaches were evaluated, such as heat pipes for the radiator and alternate fluids for the coolant loops. Emphasis was placed on using Shuttle developed hardware: coolant pumps, heat exchangers, fluids, and radiator technology.
Data reduction programs for a laser radar system
The listing and description of software routines which were used to analyze the analog data obtained from LIDAR - system are given. All routines are written in FORTRAN - IV on a HP - 1000/F minicomputer which serves as the heart of the data acquisition system for the LIDAR program. This particular system has 128 kilobytes of highspeed memory and is equipped with a Vector Instruction Set (VIS) firmware package, which is used in all the routines, to handle quick execution of different long loops. The system handles floating point arithmetic in hardware in order to enhance the speed of execution. This computer is a 2177 C/F series version of HP - 1000 RTE-IVB data acquisition computer system which is designed for real time data capture/analysis and disk/tape mass storage environment.