Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GRATINGS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

FUSE/Lyman grant

A variety of options for a short wavelength spectrometer for the Lyman telescope has been studied, and the optimum configuration for this instrument identified. In this spectrometer option study it is assumed (consistent with performance goals outlined by the project) that the instrument, whose prime spectral domain is 900-12000A, will incorporate a grazing incidence telescope which will maintain good collecting efficiency down to 100A. In particular it is assumed that the telescope will have an effective focal length of 10 meters, an image quality of 1.5", and will provide a diverging f/10 beam. Designs compatible with this telescope are analyzed, and it is determined that a two-element grazing incidence spectrometer using as its first optic an ellipsoid to re-focus the beam and a varied line-space plane diffraction grating to disperse the light is the best overall design. This spectrometer could be fed by a small pick-off mirror located just behind the prime focus of the telescope and would clear the light path when not in use. A test of the diffraction efficiency of a low blaze angle grating is undertaken, which is the only technical uncertainty in the spectrometer design.

Hurwitz, M.↗

Spectral variability of Cygnus X-2 - Structure in the circumsource material

Cygnus X-2 was observed during 13 separate pointings in the course of 1 yr by the Einstein monitor proportional counter. During one of these pointings the objective grating spectrometer was also used. It is found that the data from these observations are well fitted by single-component thermal bremsstrahlung models with temperatures ranging from 4-12 keV; however, two-component models, where one component is a blackbody, are not excluded. The X-ray light curve appears to be correlated with the 9.843 day optical period, possibly implying a partial eclipse of the X-ray source. During the high states there are irregular dips of up to 30 percent in intensity that last for 300-700 s. The high spectra resolution grating data were taken during one of the high states when these dips occurred, and it is possible to distinguish variable variable emission and absorption features due to Fe, O, and Ne. The picture of Cygnus X-2 is consistent with an intrinsic thermal source surrounded by a hot accretion disk corona. This model can be used to explain the high and low X-ray states, the variability within the states, and the intensity dips which occur in the high states.

Vrtilek, S. D.↗

A high resolution spectrometer for EUV/FUV wavelengths

The most efficient of the various configurations considered for a high-resolution spaceborne spectrometer for point-source astronomy in the 400-1200-A wavelength region which will fit within an envelope defined by the projected Spartan space platform is a multiple Rowland circle spectrograph, with each of four toroidal gratings respectively intercepting a fraction of the primary mirror beam. Each spectrometer can accept a rather slowly diverging beam, reducing grating aberrations, without further efficiency loss due to additional reflections or magnification. The line densities, detector size, pixel size, etc., of the detector for this instrument are dependent on the drift rate of the space platform; a design optimized for an uncorrected 4-arcsec drift is presented.

Hurwitz, Mark↗

Simplified dichromated gelatin hologram recording process

A simplified method for making dichromated gelatin (DCG) holographic optical elements (HOE) has been discovered. The method is much less tedious and it requires a period of processing time comparable with that for processing a silver halide hologram. HOE characteristics including diffraction efficiency (DE), linearity, and spectral sensitivity have been quantitatively investigated. The quality of the holographic grating is very high. Ninety percent or higher diffraction efficiency has been achieved in simple plane gratings made by this process.

Georgekutty, Tharayil G.↗

Real-Time Keratometer

Optical/electronic keratometer system produces contour map of corneal surface illuminated by infrared light pulses. Prevents operator error and eliminates need to apply fluorescent liquids to cornea. Keratometer provides both video display and numerical recording for corneal-transplant and radial-keratotomy surgery and for contact-lens fitting. Optical system of keratometer, circular grating pattern transmitted to corneal surface reflected onto identical circular grating on surface of fiber plate, producing Moire pattern. Data-analysis-and-display mode, laser light pulsed, and Moire pattern converted to digital information in frame grabber. Digital picture information sent to computer for processing and display.

Frazer, Robert E.↗

Distributed feedback lasers

A ridge waveguide distributed feedback laser was developed in InGaAsP. These devices have demonstrated CW output powers over 7 mW with threshold currents as low as 60 mA at 25 C. Measurements of the frequency response of these devices show a 3 dB bandwidth of about 2 GHz, which may be limited by the mount. The best devices have a single mode spectra over the entire temperature range tested with a side mode suppression of about 20 dB in both CW and pulsed modes. The design of this device, including detailed modeling of the ridge guide structure, effective index calculations, and a discussion of the grating configuration are presented. Also, the fabrication of the devices is presented in some detail, especially the fabrication of and subsequent growth over the grating. In addition, a high frequency fiber pigtailed package was designed and tested, which is a suitable prototype for a commercial package.

Ladany, I.↗

Self-pulsing and bichromatic emission in homogeneously broadened bidirectional ring lasers

The effects of saturation-induced Bragg gratings on the mode structure and dynamics of bidirectional homogeneously broadened ring lasers are studied. The grating is viewed as a distributed feedback medium in a ring cavity and modes appropriate to such a structure are used. A Fourier decomposed rate equation model is developed to study the behavior of these modes above threshold. The difference in the properties of these solutions from the modes of an unfilled ring cavity lead to the possibility of bichromatic emission and both regular undamped and irregular damped self-pulsing.

Rabinovich, W. S.↗

Imaging spectrometer for high resolution measurements of stratospheric trace constituents in the ultraviolet

A high-resolution spectrometer has been developed for studies of minor constituents in the middle atmosphere at ultraviolet wavelengths. In particular, the instrument is intended for observations of upper stratospheric UV bands. The spectrometer has a slit width of 0.08 A obtained by means of an echelle grating and a cross-disperser grating. The image plane detector is an intensified CCD consisting of a high gain proximity focused image intensifier that is fiber optically coupled to a two-dimensional CCD array. An instantaneous bandwidth of 9.2 A is resolved across 488 pixels at 0.018 A/pixel, permitting simultaneous acquisition of multiple lines of selected OH bands and the neighboring background. The spectrometer and the approach have been successfully demonstrated as a technique for measuring the concentration of OH on two high-altitude balloon flights. This paper reports the instrument design and its achieved performance.

Torr, Marsha R.↗

Ground based infrared astronomy

Infrared spectroscopic instrumentation has been developed for ground-based measurements of astrophysical objects in the intermediate infrared. A conventional Michelson interferometer is limited for astronomical applications in the intermediate infrared by quantum noise fluctuations in the radiation form the source and/or background incident on the detector, and the multiplex advantage is no longer available. One feasible approach to recovering the multiplex advantage is post-dispersion. The infrared signal after passing through telescope and interferometer, is dispersed by a low resolution grating spectrometer onto an array of detectors. The feasibility of the post-dispersion system has been demonstrated with observations of astrophysical objects in the 5 and 10 micrometer atmospheric windows from ground-based telescopes. During FY87/88 the post-disperser was used at the Kitt Peak 4-meter telescope and McMath telescope with facility Fourier transform spectrometers. Jupiter, Saturn, Mars, and Venus were observed. On Jupiter, the resolution at 12 micrometer was 0.01/cm, considerably higher than had been acheived previously. The spectrum contains Jovian ethane and acetylene emission. Construction was begun on the large cryogenic grating spectrometer.

Jennings, D. E.↗

Precision in the perception of direction of a moving pattern

The precision of the model of pattern motion analysis put forth by Adelson and Movshon (1982) who proposed that humans determine the direction of a moving plaid (the sum of two sinusoidal gratings of different orientations) in two steps is qualitatively examined. The volocities of the grating components are first estimated, then combined using the intersection of constraints to determine the velocity of the plaid as a whole. Under the additional assumption that the noise sources for the component velocities are independent, an approximate expression can be derived for the precision in plaid direction as a function of the precision in the speed and direction of the components. Monte Carlo simulations verify that the expression is valid to within 5 percent over the natural range of the parameters. The expression is then used to predict human performance based on available estimates of human precision in the judgment of single component speed. Human performance is predicted to deteriorate by a factor of 3 as half the angle between the wavefronts (theta) decreases from 60 to 30 deg, but actual performance does not. The mean direction discrimination for three human observers was 4.3 plus or minus 0.9 deg (SD) for theta = 60 deg and 5.9 plus or minus 1.2 for theta = 30 deg. This discrepancy can be resolved in two ways. If the noises in the internal representations of the component speeds are smaller than the available estimates or if these noises are not independent, then the psychophysical results are consistent with the Adelson-Movshon hypothesis.

Stone, Leland S.↗

AlGaAs phased array laser for optical communications

Phased locked arrays of multiple AlGaAs diode laser emitters were investigated both in edge emitting and surface emitting configurations. CSP edge emitter structures, coupled by either evanescent waves or Y-guides, could not achieve the required powers (greater than or similar to 500 mW) while maintaining a diffraction limited, single lobed output beam. Indeed, although the diffraction limit was achieved in this type of device, it was at low powers and in the double lobed radiation pattern characteristic of out-of-phase coupling. Grating surface emitting (GSE) arrays were, therefore, investigated with more promising results. The incorporation of second order gratings in distribute Bragg reflector (DBR) structures allows surface emission, and can be configured to allow injection locking and lateral coupling to populate 2-D arrays that should be able to reach power levels commensurate with the needs of high performance, free space optical communications levels. Also, a new amplitude modulation scheme was developed for GSE array operation.

Carlson, N. W.↗

Optically-Tuned Far-Infrared Device

Spacing of visible interference pattern determines frequency of infrared radiation. Variable photoconductivity grating formed by interference of two visible laser beams intersecting on surface of proposed AlGaAs device substituted for fixed metal grating. Proposed device provides higher output-power density and greater tunability.

Katz, Joseph↗

Deferred electronic heterodyne moire deflectometry: A method for transient density fields measurement

Effects of spherical aberrations of the mirror used in the moire system on the angular resolution of the system are investigated. It is shown that the spherical aberrations may reduce significantly the performance of the conventional moire deflectometer. However, due to the heterodyne procedure, this is not the case with the heterodyne moire system. A moire system with a constant speed moving grating is demonstrated. It is shown that the system readout is linear and the system does not need calibration. In addition, the repeatability of the measurements is improved in this system as compared to the sinusoidally moving grating setup. The problem of the photographic plates alignment is solved by using a mechanical system in which the plate is held firmly throughout the experiment and accurately replaced after removing for photographic processing. The effect of a circular detector's aperture size on readout was tested. It is shown that the spatial phase variations, observed when scanning along a straight moire fringe, may considerably be reduced. At present we may say that both the on-line and the deferred heterodyne moire techniques may reliably be used. The errors of phase readings are 1 deg and 5 deg for the on-line and deferred methods. The total error due to subtraction of two readings at each position is, therefore, 1.4 deg and 7 deg, respectively. Further research for improving the deferred system is suggested.

Stricker, Josef↗

Exosat observations of Cygnus X-2 continuum and line spectrum

An analysis of five Exosat observations of Cyg X-2, taken around a full binary orbit is presented. The data were obtained using all instrumentation (1000 lines/mm Transmission Grating Spectrometer, Channel Multiplier Array + filters, Medium-Energy experiment, and Gas Scintillation Proportional Counter) simultaneously, and span the full energy range 0.5-20 keV. No clear evidence was found for a correlation of any of the source characteristics with orbital phase. During two of the observations, significant iron K emission at 6.7 keV was detected, the relative strength of which seems to correlate with total X-ray intensity during two sharp intensity dips. The previous detection of discrete emission features in the 12-19 A band with the Einstein grating is confirmed.

Chiappetti, L.↗

Multiaperture Spectrometer

Proposed multiaperture spectrometer containing single grating provides high spectral resolution over broad spectrum. Produces parallel line images, each of which highly spectrally resolved display of intensity vs. wavelength in wavelength band of one of orders of spectrum produced by grating. Advantages; convenient two-dimensional spectral image, fewer components, and greater efficiency.

Schindler, Rudolf A.↗

Structures and characteristics of commercially available 1.5 micron InGaAsP distributed feedback laser diodes

The characteristics of commercially available 1.5-micron distributed feedback (DFB) laser diodes obtained from seven manufacturers were investigated, and the results are correlated with the lasers' structural parameters. It was found that buried heterostructures with first-order gratings showed consistently good results (as opposed to buried heterostructures with second-order gratings). A ridge waveguide laser was near the bottom of most performance charts.

Cook, A. L.↗

Optical design of Lyman/FUSE

The optical system for the proposed Lyman/Far UV Spectroscopic Explorer (FUSE) orbiting observatory is described and illustrated with drawings and graphs of predicted performance. The system comprises (1) an FUV channel based on a 1.84-m-diameter Rowland circle spectrograph with five high-density modified ellipsiodal near-normal-incidence gratings and an array of four MAMA detectors; (2) an EUV channel with ellipsoidal mirror, planar varied-line-space grating, microchannel-plate array, and wedge-and-strip anode detector; (3) a 70-cm Wolter II glancing-incidence telescope; and (4) a CCD-detector fine-error sensor to provide accurate pointing (within 200 marcsec rms). The resolving powers of the spectrographs are 30,000 in the FUV and 300-600 (wavelength-dependent) in the EUV.

Content, D. A.↗

X-ray optics. II - A technique for high resolution spectroscopy

A novel combination of optical elements and properties is combined to achieve high-spectral resolution using grazing incidence optics of modest quality. Analysis and ray tracing of examples show that using radial groove gratings at high blaze angles in the manner of an echelle spectrograph can provide high spectral resolution. This arrangement is compared to the conventional in-plane designs to show that the off-plane is superior in nearly every respect. Cross dispersion can be provided by the energy resolution of a CCD detector. Additional resolution can be squeezed from the system by strategic placement of gratings to take advantage of the azimuthal response of a Wolter X-ray optic.

Cash, Webster C., Jr.↗