At least 793 records · Page 44

Quarkonium mass splittings with Fermilab heavy quarks and 2+1 flavors of improved staggered sea quarks

We present results from an ongoing lattice study of the lowest lying charmonium and bottomonium level splittings using the Fermilab heavy quark formalism. Our objective is to test the performance of this action on MILC-collaboration ensembles of (2+1) flavors of light improved staggered (asqtad) quarks. Measurements are done on 16 ensembles with degenerate up and down quarks of various masses, thus permitting a chiral extrapolation, and over lattice spacings ranging from 0.09 fm to 0.18 fm, thus permitting study of lattice-spacing dependence. We examine combinations of the mass splittings that are sensitive to components of the effective quarkonium potential.

Burch, T.↗

The Mu2e Experiment at Fermilab

Mu2e is an experiment under construction at Fermilab that will search for the coherent neutrinoless conversion of a muon into an electron in the field of an atomic nucleus. This is a charged-lepton flavour violating process, and its observation would be clear evidence of physics beyond the standard model. Mu2e's single-event sensitivity of $3\times 10^{-17}$ is 4 orders of magnitude better than previous experiments looking at this reaction, and indirectly probes energy scales beyond those envisioned for high-energy colliders. To achieve the high sensitivity requires a very intense but low-energy muon beam, a high-precision measurement of the conversion electron's momentum, and several key mechanisms to reduce background events. This work presents an overview of the experimental design and construction status, focusing on four "Big Deal" items which are particularly innovative or interesting.

Caron, Jean-François↗

The Muon $g-2$ experiment at Fermilab and the First Physics Run

Measurement of the muon anomalous magnetic moment (muon g-2) is a sensitive tool for testing the Standard Model (SM) and searching for new physics. It is an important and complementary tool to probe the high energy frontier. In this talk, I will provide an overview on the Fermilab Muon g-2 experiment, which aims to perform the measurement the muon g-2 with a precision goal of 140 parts per billion, a fourfold improvement over the previous BNL measurement. The first physics run finished in 2018 collecting a data sample with similar size of the BNL measurement. The current experimental status and prospects of the experiment will also be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring the muon precession frequency in the E989 Fermilab g-2 experiment

Since more than 50 years the electron and muon anomalies, $a_e$ and $a_\mu$, defined in terms of the gyromagnetic factor $g_i$ for particle $i$ as $a_i=(g_i-2)/2$, have provided a deep insight into the quantum structure of elementary particles.They have been, and continue to be, a milestone for the development of the Standard Model of Particle Physics against which all new theories have to be compared.For almost 20 years, the experimental value of $a_\mu$ has shown a tantalizing discrepancy of more than $3 \sigma$ from the theoretical prediction making it mandatory for experimentalists to improve the current result, dominated by the E821 experiment at BNL\cite{BNL}. The Muon $g-2$ E989 experiment at Fermilab will use the same storage ring technique used at BNL, and previously in the CERN-III experiment, with the goal of decreasing by a factor of 4 the current error on $a_\mu$, which will allow for a finer comparison with the theoretical prediction. E989 started collecting data in winter 2018 accumulating, in the period April-July 2018 (Run1) almost twice the statistics of the previous experiment (before application of data quality cuts). In this document, the experiment will be briefly described, underlying the improvements which will allow to reduce the systematic error, and some preliminary result will be shown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The muon g-2 experiment at Fermilab

The E989 collaboration has recently published the most precise measurement of the muon anomalous magnetic moment $a_\mu$ with an uncertainty of $0.46\,\mathrm{ppm}$. The new experimental world average of $a_\mu$ deviates by 4.2 standard deviations from the Standard Model prediction provided by the Muon g-2 Theory Initiative. Emerging results from ab-initio lattice QCD calculations for hadron-physics contributions allow to scrutinize this tantalizing hint for physics beyond the Standard Model for the first time in a three way comparison. To extract the value of $a_\mu$ a frequency comparison experiment is performed with spin-polarized muons confined in a superbly controlled electric and magnetic field environment. A measurement of the difference between the Larmor and the cyclotron frequency, the so-called anomalous spin precession frequency, is combined with a high-precision measurement of the magnetic field environment which is performed using nuclear magnetic resonance techniques. I discussed the most recent result of the Fermilab Muon g-2 experiment's first physics data run performed in 2018. I reported on the experimental improvements implemented for the subsequent science runs that will allow the collaboration to achieve the ultimate goal of $0.14\,\mathrm{ppm}$ uncertainty on $a_\mu$.

Fertl, Martin↗

Development, construction and qualification tests of the mechanical structures of the electromagnetic calorimeter of the Mu2e experiment at Fermilab

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the Charged Lepton Flavour Violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of physics beyond the Standard Model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides excellent electron identification, complementary information to aid pattern recognition and track reconstruction, and a fast calorimetric online trigger. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1340 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements.The hostile Mu2e operational conditions, in terms of radiation levels (total ionizing dose of 12 krad and a neutron fluence of 5x1010 n/cm2 @ 1 MeVeq (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on the design of the detector mechanical structures and materials choice. The support structure of the two 670 crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and service front-end electronics for each crystal are assembled in a unique mechanical unit inserted in a machined copper holder. The 670 units are supported by a machined plate made of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics is hosted in aluminum custom crates positioned on the external lateral surface of the two disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system.The constraints on the calorimeter mechanical structures design, the development from the conceptual design to the specifications of all the structural components, the status of components production and the components quality assurance tests are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Short Baseline Neutrino Program at Fermilab

The current status of the Short Baseline Neutrino (SBN) project at Fermilab is reviewed. While the installation of SBND is still in progress, ICARUS has taken its first neutrino data on beam:using both the Booster Neutrino Beam (BNB) and the Neutrino at the Main Injector (NuMI) beam.MicroBooNE has presently completed its data taking and is producing the world’s first high statistics results on neutrino Argon interactions, in both inclusive and exclusive channels. In parallel, the unexpected MiniBooNE “low energy excess” is under investigation, to search for sterile neutrinos.The physics potential for sterile neutrino searches at SBN will be outlined, with emphasis on the Neutrino-4 experiment and the possible ICARUS verification of this claim.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Field Analysis for Fermilab Muon $g-2$

The Muon g-2 experiment E989 at Fermilab measures the anomalous magnetic moment of the muon $a_\mu$ with improved precision compared to the Brookhaven (E821) experiments. The Brookhaven results are in tension with the Standard Model by more than $3\sigma$. The determination of $a_\mu$ requires the measurement of both the muon anomaly frequency, $\omega_a$, and the magnetic field, $\mathbf{B}$, that confines muons in a storage ring. The field is monitored by a set of coordinated nuclear magnetic resonance (NMR) measurements. NMR probes at fixed locations above and below the storage region constantly monitor the field. An in-vacuum trolley equipped with 17 NMR probes maps the muon storage region, and a special water-based NMR probe provides the calibration for the trolley probes. This presentation focuses on the determination of the time-dependent field maps from combining the fixed probe measurements and the trolley maps. The field maps are combined with the muon distribution to derive the average field observed by the muons during the measurement. These proceedings will cover the analysis from the first data run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the anomalous spin precession frequency $\omega_a$ in the Muon $g-2$ experiment at Fermilab

The muon anomaly, $a_\mu=(g_{\mu}-2)/2$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model (SM) and a probe for new physics. The current discrepancy between the experimental value and the Standard Model calculation from the Muon $g-2$ Theory Initiative is $a_{\mu}^{exp}-a_{\mu}^{SM}=(251\pm59)\cdot10^{-11}$, with a significance of $4.2\,\sigma$.The Fermilab E989 experiment aims, with the full statistical power, to improve by a factor of four the precision of the measurement.In April 2021 the collaboration published the first measurement, based on the first year of data taking.This paper will present the status of the measurement of the anomalous muon spin precession frequency, $\omega_a$, performed on the datasets collected during Run-2 and Run-3 (2019 and 2020 campaigns), with a preliminary projection of the systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the muon anomalous precession frequency $\omega_a$ in the Fermilab $g-2$ experiment

The Fermilab Muon $g-2$ Experiment was designed to measure the muon's anomalous magnetic moment $a_{\mu} = (g-2)/2$ to 140 parts per billion. The value of $a_{\mu}$ is proportional to the difference frequency $\omega_a=\omega_s-\omega_c$ between the muon's cyclotron frequency and spin precession frequency in the uniform magnetic field of the $g-2$ storage ring. The frequency $\omega_a$ is extracted from the time distribution of the mu-decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. We will discuss the various approaches to the frequency determination including the reconstruction, fitting of time distributions, and procedures for handling the effects of gain changes, positron pileup and beam dynamics. We also discuss the data consistency checks and the strategy for the averaging of $\omega_a$ across the different analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results from the Muon g-2 experiment at Fermilab

The goal of the Muon g-2 experiment at Fermilab is to measure the muon magnetic momentanomaly with a final accuracy of 140 parts per billion (ppb). The experiment has published tworesults based on the data collected in 2018 (Run-1) and 2019-2020 (Run-2/3), respectively. These results confirm the previous measurement performed 20 years ago at Brookhaven National Laboratory, and their combination reaches the unprecedented uncertainty of 200 ppb. This proceeding presents a brief overview of the Standard Model prediction for the muon g-2. It then summarizes the experimental measurement technique and the Run-1 and Run-2/3 measurements, detailing the improvements in their systematic and statistical uncertainties. Finally, it illustrates the comparison between theory and experiment and discusses future prospects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision Measurement of the Muon Spin Precession Frequency in the Fermilab Muon g-2 Experiment

The Fermilab Muon $g-2$ Experiment is designed to measure the muon's anomalous magnetic moment, $ a_\mu = (g-2)/2 $ with an accuracy of 140 parts per billion. This quantity is determined from two key measurements; the difference between the muon's spin precession frequency and its cyclotron frequency, given by $\omega_a = \omega_s - \omega_c$, and $\tilde{\omega_p^\prime}$, proportional to the muon-weighted magnetic field.In this talk, we focus on presenting the methodology for determining $\omega_a$. Muons with a momentum of 3.1 GeV are injected into a storage ring, and $\omega_a$ is extracted from the time distribution of decay positrons recorded by 24 electromagnetic calorimeters placed symmetrically inwards around the ring. We present the final result from the muon g-2 collaboration and analysis techniques based on data collected from 2020 to 2023.

Zaid, Estifa'a [Liverpool U.]↗

The first measurement of the muon anomalous magnetic moment from the Fermilab Muon g-2 collaboration

This paper will cover the physics and methods behind Fermilab’s Muon g-2 Experiment, along with the long-awaited results from Run-1. The experiment was undertaken to resolve the tension between the Standard Model and the previous measurement taken at Brookhaven National Laboratory. The measured value of the muon magnetic anomaly is a µ (FNAL) = 116592040(54) × 10 -11 . This result is in good agreement with Brookhaven’s previous measurement. The new world average, a µ (Exp) = 116592061(41) × 10 -11 , shows a difference from the theoretical value of the Standard Model (SM), a µ (SM) = 116591810(43) × 10 -11 , of 4.2 standard deviations, strongly hinting at physics beyond the Standard Model. The experiment requires the simultaneous measurement of the muon precession frequency, the magnetic field, and the muons’ distribution in the field. All three of these measurements will be discussed in context, along with the main systematic corrections and uncertainties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Autoencoder Based Analysis of RF Parameters in the Fermilab Low Energy Linac

Machine learning (ML) has the potential for significant impact on the modeling, operation, and control of particle accelerators due to its ability to model nonlinear behavior, interpolate on complicated surfaces, and adapt to system changes over time. Anomaly detection in particular has been highlighted as an area where ML can significantly impact the operation of accelerators. These algorithms work by identifying subtle behaviors of key variables prior to negative events. Efforts to apply ML to anomaly detection have largely focused on subsystems such as RF cavities, superconducting magnets, and losses in rings. However, dedicated efforts to understand how to apply ML for anomaly detection in linear accelerators have been limited. In this paper the use of autoencoders is explored to identify anomalous behavior in measured data from the Fermilab low-energy linear accelerator.

Edelen, Jonathan P. (ORCID:0000000215180652)↗

Machine Learning Applications to Maintain the NuMI Neutrino Beam Quality at Fermilab

The NuMI target facility at Fermilab produces an intense muon neutrino beam for NOvA (NuMI Off-axis νe Appearance) long baseline neutrino experiment. Three arrays of muon monitors located in the downstream of the hadron absorber in the NuMI beamline provide the measurements of the primary beam and horn current quality. We have studied the response of muon monitors with the proton beam profile changes and focusing horn current variations. The responses of muon monitors are used to develop Machine Learning (ML) algorithms to monitor the beam quality. We present the development of the machine learning applications and the future plans. This effort is important for future applications such as beam quality assurance, anomaly detections, neutrino beam systematics studies and neutrino beam quality assurance. Our results demonstrate the advantages of developing useful ML applications that can be leveraged for future beamlines such as LBNF.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Third generation residual gas ionization profile monitors at Fermilab

The latest generation of IPMs installed in the Fermilab Main Injector and Recycler incorporate a 1 kG permanent magnet, a newly designed high-gain, rad-tolerant preamp, and a control grid to moderate the charge that is allowed to arrive on the anode pick-up strips. The control grid is intended to select a single Booster batch measurement per turn. Initially it is being used to allow for a faster turn-on of a single, high-intensity cycle in either machine. The expectation is that this will extend the Micro Channel Plate lifetime, which is the high-cost consumable in the measurement system. We discuss the new design and data acquired with this system.

Zagel, J. R.↗

Run 2/3 measurement of the muon anomalous magnetic moment by the Muon g-2 experiment at Fermilab

The Muon g-2 experiment at Fermilab seeks to measure the muon magnetic moment anomaly, $a_μ=(g-2)/2$, with a final target precision of 0.14 parts-per-million (ppm). The experiment's initial result, published in 2021 using Run 1 data from 2018, confirmed the previous measurement at Brookhaven National Laboratory with a comparable sensitivity of 0.46 ppm. In 2023, a new result based on Run 2 and Run 3 data, collected in 2019 and 2020, was released. These datasets contain four times the data from Run 1, significantly enhancing sensitivity and achieving an unprecedented uncertainty of 0.20 ppm. This advancement resulted in a two-fold improvement in both statistical and systematic uncertainties. Here, we will discuss the muon $g-2$ measurement, the increased precision relative to the Run 1 result, and provide an outlook on future measurements which will incorporate datasets from 2021 to 2023. Additionally, we will explore the implications of comparing the new measurements with the latest Standard Model predictions for muon g-2.

Zaid, Estifa'a [Liverpool U.]↗

The Fermilab Short-Baseline Program: MicroBooNE

The MicroBooNE experiment is the first of three detectors of the Fermilab short-baseline neutrino program that started operation in the Booster Neutrino Beamline in October 2015 [1]. When completed, the three-detector lineup will explore short-baseline neutrino oscillations and will be sensitive to sterile neutrino scenarios. MicroBooNE in itself is now starting its own physics program, with the measurement of neutrino-argon cross sections in the ~1GeV range being one of its main physics goals. These proceedings describe the status of the detector, the start of operation, and the automated reconstruction of the first neutrino events observed with MicroBooNE. Prospects for upcoming cross section measurements are also given.