Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLASH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Global Patterns of Lightning Properties Derived by OTD and LIS

The satellite instruments Optical Transient Detector (OTD) and Lightning Imaging Sensor (LIS) provide unique empirical data about the frequency of lightning flashes around the globe (OTD), and the tropics (LIS), which 5 has been used before to compile a well received global climatology of flash rate densities. Here we present a statistical analysis of various additional lightning properties derived from OTD/LIS, i.e. the number of so-called "events" and "groups" per flash, as well as 10 the mean flash duration, footprint and radiance. These normalized quantities, which can be associated with the flash "strength", show consistent spatial patterns; most strikingly, oceanic flashes show higher values than continental flashes for all properties. Over land, regions with high (Eastern US) 15 and low (India) flash strength can be clearly identified. We discuss possible causes and implications of the observed regional differences. Although a direct quantitative interpretation of the investigated flash properties is difficult, the observed spatial patterns provide valuable information for the 20 interpretation and application of climatological flash rates. Due to the systematic regional variations of physical flash characteristics, viewing conditions, and/or measurement sensitivities, parametrisations of lightning NOx based on total flash rate densities alone are probably affected by regional biases.

Beirle, Steffen↗

Size, duration, and rate of growth of nocturnal lightning events appearing on space shuttle video tapes

An analysis of video tapes of nocturnal lightning events, taken aboard space shuttle flights STS-8, STS-9, STS-41D, and STS-51J, shows flashes with dimensions ranging from approximately 1 km by 1 km to 440 km by 110 km. Of particular interest are the flashes whose dimensions exceeded 100 km, as flashes of this size are seldom reported. In general, larger flashes were found to have longer durations, take longer to reach their maximum extent, and reach their maximum extent at a smaller percent of their total duration than smaller flashes. Sixty four percent of the flashes occurred with one to five other events appearing in the same video frame. These simultaneous events were an average of 60 km apart from each other. If a breakdown process is propagating between the simultaneous flashes, it would be travelling at a rate of 10(exp 5)m/sec. Plots of the area of an event over its duration show peaks in the area curve which may be indicative if lightning strokes. There was an average of 3.6 peaks per flash. In general, the longer the flash duration, the more peaks there were in the area curve. The area curves of the lightning events fall into one of five shape categories. It is suggested that the shape of the area curve may indicate whether an event is an intracloud or cloud to ground lightning flash. Some of the lightning events had a persistent bright spot. These events had an average duration which was greater than that of events without the bright spot. On average, the bright spot events had a maximum area which was larger than that of the flashes without the bright spot.

Breslawski, Christine↗

Florida Thunderstorms: A Faucet of Reactive Nitrogen to the Upper Troposphere

During the NASA Cirrus Regional Study of Tropical Anvils and Cirrus Layers-Florida Area Cirrus Experiment (CRYSTAL-FACE) enhanced mixing ratios of nitric oxide were measured in the anvils of thunderstorms and in clear air downwind of storm systems on flights of a Wl3-57F high-altitude aircraft. Mixing ratios greater than l0 - 20 times background were readily observed over distances of 25-120 km due to lightning activity. In many of the Florida storms deposition of NO occurred up to near the tropopause but major deposition usually occurred 1 - 2 km below the tropopause, or mostly within the visible anvil volume formed prior to storm decay. Observations from two storms of very different anvil size and electrical activity allowed estimates of the total mass of NO, vented to the middle and upper troposphere. Using the cloud-to ground (CG) flash accumulations from the National Lightning Detection Network, climatological intra-cloud (IC) to CG ratios, and assuming that CG and IC flashes were of equivalent efficiency for NO production, the ranges of production per flash for a moderate-sized and a large storm were (0.51 - 1.0) x l0(exp 26) and (2.3 - 3.1) x 10(exp 26) molecules NO/flash, respectively. Using the recently determined average global flash rate of 44 8, a gross extrapolation of these two storms to represent possible global annual production rates yield 1.6 - 3.2 and 7.3 - 9.9 Tg(N)/yr, respectively. If the more usual assumption is made that IC efficiency is l/l0th that of CG activity, the ranges of production for the moderate-sized and large storm were (1.3 - 2.7) x l0(exp 26) and (6.0 - 8.1) x l0(exp 26) molecules NO/CG flash, respectively. The estimates from the large storm may be high because there is indirect evidence that the IC/CG ratio was larger than would be derived from climatology. These two storms and others studied did not have flash rates that scaled as approx. H(sup 5) where H is the cloud top altitude. The observed CG flash accumulations and NO(x) mass production estimate for the month of July over the Florida area were compared with a representative 3D global Chemistry-Transport Model (CTMJ that uses the Price et al. lightning parameterization. For two land grid points representing the Florida peninsula the model compared well with the observations: CG flash rates were low by only a factor of approx. 2. When the model grid points included the coastal regions of Florida the flash accumulations were lower than observed by a factor of 3.4 - 4.6. It is recommended that models using the Price et al. parameterization allow any global coastal grid point to maintain the land rather than the marine flash rate parameterization. The convection in this CTM underestimated the actual cloud top heights over Florida by 1 - 2 km and thus the total lightning flash rates and the altitude range of reactive nitrogen deposition. Broad scale (20 - 120 km) median mixing ratios of NO within anvils over Florida were significantly larger than in storms previously investigated over Colorado and New Mexico.

Ridley, B.↗

Synchronized Electronic Shutter System (SESS) for Thermal Nondestructive Evaluation

The purpose of this paper is to describe a new method for thermal nondestructive evaluation. This method uses a synchronized electronic shutter system (SESS) to remove the heat lamp's influence on the thermal data during and after flash heating. There are two main concerns when using flash heating. The first concern is during the flash when the photons are reflected back into the camera. This tends to saturate the detectors and potentially introduces unknown and uncorrectable errors when curve fitting the data to a model. To address this, an electronically controlled shutter was placed over the infrared camera lens. Before firing the flash lamps, the shutter is opened to acquire the necessary background data for offset calibration. During flash heating, the shutter is closed to prevent the photons from the high intensity flash from saturating the camera's detectors. The second concern is after the flash heating where the lamps radiate heat after firing. This residual cooling introduces an unwanted transient thermal response into the data. To remove this residual effect, a shutter was placed over the flash lamps to block the infrared heat radiating from the flash head after heating. This helped to remove the transient contribution of the flash. The flash lamp shutters were synchronized electronically with the camera shutter. Results are given comparing the use of the thermal inspection with and without the shutter system.

Zalameda, Joseph N.↗

Performance Assessment of the Optical Transient Detector and Lightning Imaging Sensor: Clustering Algorithm - Part 2

We describe the clustering algorithm used by the Lightning Imaging Sensor (LIS) and the Optical Transient Detector (OTD) for combining the lightning pulse data into events, groups, flashes, and areas. Events are single pixels that exceed the LIS/OTD background level during a single frame (2 ms). Groups are clusters of events that occur within the same frame and in adjacent pixels. Flashes are clusters of groups that occur within 330 ms and either 5.5 km (for LIS) or 16.5 km (for OTD) of each other. Areas are clusters of flashes that occur within 16.5 km of each other. Many investigators are utilizing the LIS/OTD flash data; therefore, we test how variations in the algorithms for the event group and group-flash clustering affect the flash count for a subset of the LIS data. We divided the subset into areas with low (1-3), medium (4-15), high (16-63), and very high (64+) flashes to see how changes in the clustering parameters affect the flash rates in these different sizes of areas. We found that as long as the cluster parameters are within about a factor of two of the current values, the flash counts do not change by more than about 20%. Therefore, the flash clustering algorithm used by the LIS and OTD sensors create flash rates that are relatively insensitive to reasonable variations in the clustering algorithms.

Mach, Douglas M.↗

Characteristics of Winter Lightning Currents Struck an Isolated Tower

To make clear the characteristics of winter lightning flashes, the current waveforms of winter lightning flashes were measured by two resistive shunts which were connected to two lighting rods since the winter of 1981, and another measurement has started using a set of five Rogowsky type coils since the winter of 1982. They were recorded by computer controlled digital recording systems. Up to date, 145 current waveforms of the winter lightning flashes, which have the current amplitude over 1 kA, were obtained by the shunt systems and/or the coils system. They show that winter lightning flashes often have a very long duration or continuing current and sometimes have a very large amplitude over 200 kA in positive flashes. For example, the current parameters that were measured on 9 Jan. 1987 were the maximum current amplitude, +280 kA, maximum current derivative 1.0 x 10(exp 10) A/s, total charge +400 C, and action integral 1.5 x 10(exp 7)(sq. A)(s). The statistical evaluation shows that medium peak values of winter lightning flashes (50 percent values) were about 5 kA for negative and 10 kA for positive, and 5 percent values were about 30 kA for negative and 170 kA for positive. The winter lightning current waveforms are classified into three types: single stroke flashes, monopolar multistroke flashes, and bipolar flashes. Moreover, each flash is subdivided into positive or negative, single peak or multipeak, and with or without continuing current.

Yukihiro Goto↗

A LIS Validation Study at the KSC-ER using LDAR and Field Mill Data

The chance of having the TRMM satellite pass over east central Florida when there is lightning over the NASA Kennedy Space Center (KSC) and USAF Eastern Range (ER) is small; however, such a condition did occur on September 21, 1998 (Day 264). Starting at about 20:40 GMT, the Lightning Imaging Sensor (LIS) reported 5 flashes during a 90 second interval that the KSC-ER was within the sensor field of view. Ground-based instrumentation, the Lightning Detection and Ranging (LDAR) system and a network of electric field mills (FM), detected 6 flashes in the same interval. In this paper, we will compare the times and locations of the optical pulses that were detected by LIS with the times and locations of RF sources (LDAR) and the charges that were deposited by the flash (FM network). We will show that LIS responded to all flashes that the LDAR and FM network detected; however, two discharges that were separated by less than 1 second in time and by about 10 km in space were grouped as one flash by the LIS data processing algorithm. In spite of the fact that all flashes occurred near the edge of the LIS field of view, the locations of the LIS events were consistent with both the LDAR and FM locations (the latter are usually within 1-2 kilometers of each other and often are co-located). Two of the 5 flashes reported by LIS were shifted north by about 8 km from the corresponding LDAR and FM locations. The LIS flash times tended to be after the first LDAR pulse was detected and before the last, and the integrated light signal (per LIS event) was surprisingly constant over the 5 flashes that were detected by LIS. In the future, we plan to study more correlated events and will try to determine whether and how the LIS light signal is related to the charge transfer in the flash and/or the number and spatial extent of RF sources.

Koshak, William J.↗

Lightning NO(x) Production and Its Consequences for Tropospheric Chemistry

Cloud-resolving case-study simulations of convective transport and lightning NO production have yielded results which are directly applicable to the design of lightning parameterizations for global chemical transport models. In this work we have used cloud-resolving models (the Goddard Cumulus Ensemble Model (GCE) and MMS) to drive an off-line cloud-scale chemical transport model (CSCTM). The CSCTM, in conjunction with aircraft measurements of NO(x) in thunderstorms and ground-based lightning observations, has been used to constrain the amount of NO produced per flash. Cloud and chemistry simulations for several case studies of storms in different environments will be presented. Observed lightning flash rates have been incorporated into the CSCTM, and several scenarios of NO production per intracloud (IC) and per cloud-to-ground (CG) flash have been tested for each storm. The resulting NO(x) mixing ratios are compared with aircraft measurements taken within the storm (typically the anvil region) to determine the most likely NO production scenario. The range of values of NO production per flash (or per meter of lightning channel length) that have been deduced from the model will be shown and compared with values of production in the literature that have been deduced from observed NO spikes and from anvil flux calculations. Results show that on a per flash basis, IC flashes are nearly as productive of NO as CG flashes. This result simplifies the lightning parameterization for global models (ie., an algorithm for estimating the ICKG ratio is not necessary). Vertical profiles of lightning NOx mass at the end of the 3-D storm simulations have been summarized to yield suggested profiles for use in global models. Estimates of mean NO production per flash vary by a factor of three from one simulated storm to another. When combined with the global flash rate of 44 flashes per second from NASA's Optical Transient Detector (OTD) measurements, these estimates and the results from other techniques yield global NO production rates of 2-9 TgN/year. Simulations of the photochemistry over the 24 hours following a storm has been performed to determine the additional ozone production which can be attributed to lightning NO. Convective transport of HO(x), precursors leads to the generation of a HO(x), plume which substantially aids the downstream ozone production.

Pickering, Kenneth E.↗

Lightning NOx Production and Its Consequences for Tropospheric Chemistry

Cloud-resolving case-study simulations of convective transport and lightning NO production have yielded results which are directly applicable to the design of lightning parameterizations for global chemical transport models. In this work we have used cloud-resolving models (the Goddard Cumulus Ensemble Model (GCE) and MMS) to drive an off-line cloud-scale chemical transport model (CSCTM). The CSCTM, in conjunction with aircraft measurements of NO x in thunderstorms and ground-l;>ased lightning observations, has been used to constrain the amount of NO produced per flash. Cloud and chemistry simulations for several case studies of storms in different environments will be presented. Observed lightning flash rates have been incorporated into the CSCTM, and several scenarios of NO production per intracloud (IC) and per cloud-to-ground (CG) flash have been tested for each storm. The resulting NOx mixing ratios are compared with aircraft measurements taken within the storm (typically the anvil region) to determine the most likely NO production scenario. The range of values of NO production per flash (or per meter of lightning channel length) that have been deduced from the model will be shown and compared with values of production in the literature that have been deduced from observed NO spikes and from anvil flux calculations. Results show that on a per flash basis, IC flashes are nearly as productive of NO as CG flashes. This result simplifies the lightning parameterization for global models (ie., an algorithm for estimating the IC/CG ratio is not necessary). Vertical profiles of lightning NOx mass at the end of the 3-D storm simulations have been summarized to yield suggested profiles for use in global models. Estimates of mean NO production per flash vary by a factor of three from one simulated storm to another. When combined with the global flash rate of 44 flashes per second from NASA's Optical Transient Detector (OTD) measurements, these estimates and the results from other techniques yield global NO production rates of2-9 TgN/year. Simulations of the photochemistry over the 24 hours following a storm has been performed to determine the additional ozone production which can be attributed to lightning NO. Convective transport of HOx precursors leads to the generation of a HOx plume which substantially aids the downstream ozone production.

Pickering, Kenneth E.↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Total Lightning and Radar Storm Characteristics Associated with Severe Storms in Central Florida

This paper examines the three dimensional characteristics of lightning flashes and severe storms observed in Central Florida during 1997-1998. The lightning time history of severe and tornadic storms were captured during the on-going ground validation campaign supporting the Lightning Imaging Sensor (LIS) experiment on the Tropical Rainfall Measuring Mission (TRMM). The ground validation campaign is a collaborative experiment that began in 1997 and involves scientists at the Global Hydrology and Climate Center, MIT/Lincoln Laboratories, and the NWS Forecast Office at Melbourne, FL. Lightning signatures that may provide potential early warning of severe storms are being evaluated by the forecasters at the NWS/MLB office. Severe storms with extreme flash rates sometimes exceeding 300 per minute and accompanying rapid increases in flash rate prior to the onset of the severe weather (hall, damaging winds, tornadoes) have been reported by Hodanish et al. and Williams et al. (1998-this conference). We examine the co-evolving changes in storm structure (mass, echo top, shear, latent heat release) and kinematics associated with these extreme and rapid flash rate changes over time. The flash frequency and density are compared with the three dimensional radar reflectivity structure of the storm to help interpret the possible mechanisms producing the extreme and rapidly increasing flash rates. For two tornadic storms examined thus far, we find the burst of lightning is associated with the development of upper level rotation in the storm. In one case, the lightning burst follows the formation of a bounded weak echo region (BWER). The flash rates diminish with time as the rotation develops to the ground in conjunction with the decent of the reflectivity core. Our initial findings suggest the dramatic increase of flash rates is associated with a sudden and dramatic increase in storm updraft intensity which we hypothesize is stretching vertical vorticity as well as enhancing the development of the mixed phase region of the storm. We discuss the importance of these factors in producing both the observed extreme flash rates and the severe weather that follows in these storms and others to be presented.

Goodman, Steven J↗

The Unit of Lightning

For the past century, scientists have made quantitative measurements of lightning discharges. In the process, they refined the definition of a lightning unit, or basic quantum of lightning, in order to base it on observable parameters. Although many components of a lightning discharge have been identified, lightning usually occur in groups of discharges or pulses that, although complex, can be organized into units of flashes. This unit definition is based mainly on measurements of lightning from electric field, video, and ground flash lightning locating networks. More recent instrumentation with various combinations of high sensitivity, high temporal, or high spatial resolution often measure signals produced by lightning that do not cleanly divide into flashes. The data from these systems indicate the need or a more fundamental unit for lightning. Such a unit would be of benefit for both basic understanding of lightning and comparing lightning information between instruments. Without a common lightning unit definition, intercomparisons are difficult. For an example, the Lightning Detection And Ranging system (LDAR) at Kennedy Space Center (KSC) have detected ,flash' rates as high as 600 per minute while analysis based on the Advanced Ground Based Field Mill network (AGBFM) detect only 33 "flashes" per minute in the same area and time periods. The satellite based Optical Transient Detector (OTD) and Lightning Imaging Sensor (LIS) sometimes see single "flashes" that last longer than 10 seconds. Such long duration flashes are not found in electric field records or ground strike location system data sets. The unit of lightning should be based on the fundamental components of the lightning discharge. This should make the unit as generally applicable as possible. For example, studies of NO(x) production by lightning depend on parameters of the individual lightning channels and not the summary flash characteristics. For such studies, the best unit of lightning may be closer to the classical stroke in the electric field data sets, flash in the LDAR data sets, and group in the OTD/LIS data sets. For this type of study, however, more than just the stroke count information is needed. In this paper, we will outline the current definitions of the unit of lightning and propose new basic definitions for the unit of lightning. Since different instruments detect lightning in different ways and different studies may need almost mutually exclusive aspects of the lightning discharge, there may not be a single definition of the unit of lightning that can be applied to all systems and all studies. However, common components can be found since all instrumentation are detecting aspects of the same phenomenon.

Mach, Douglas M.↗

Saccades to remembered targets: the effects of smooth pursuit and illusory stimulus motion

1. Measurements were made in four normal human subjects of the accuracy of saccades to remembered locations of targets that were flashed on a 20 x 30 deg random dot display that was either stationary or moving horizontally and sinusoidally at +/-9 deg at 0.3 Hz. During the interval between the target flash and the memory-guided saccade, the "memory period" (1.4 s), subjects either fixated a stationary spot or pursued a spot moving vertically sinusoidally at +/-9 deg at 0.3 Hz. 2. When saccades were made toward the location of targets previously flashed on a stationary background as subjects fixated the stationary spot, median saccadic error was 0.93 deg horizontally and 1.1 deg vertically. These errors were greater than for saccades to visible targets, which had median values of 0.59 deg horizontally and 0.60 deg vertically. 3. When targets were flashed as subjects smoothly pursued a spot that moved vertically across the stationary background, median saccadic error was 1.1 deg horizontally and 1.2 deg vertically, thus being of similar accuracy to when targets were flashed during fixation. In addition, the vertical component of the memory-guided saccade was much more closely correlated with the "spatial error" than with the "retinal error"; this indicated that, when programming the saccade, the brain had taken into account eye movements that occurred during the memory period. 4. When saccades were made to targets flashed during attempted fixation of a stationary spot on a horizontally moving background, a condition that produces a weak Duncker-type illusion of horizontal movement of the primary target, median saccadic error increased horizontally to 3.2 deg but was 1.1 deg vertically. 5. When targets were flashed as subjects smoothly pursued a spot that moved vertically on the horizontally moving background, a condition that induces a strong illusion of diagonal target motion, median saccadic error was 4.0 deg horizontally and 1.5 deg vertically; thus the horizontal error was greater than under any other experimental condition. 6. In most trials, the initial saccade to the remembered target was followed by additional saccades while the subject was still in darkness. These secondary saccades, which were executed in the absence of visual feedback, brought the eye closer to the target location. During paradigms involving horizontal background movement, these corrections were more prominent horizontally than vertically. 7. Further measurements were made in two subjects to determine whether inaccuracy of memory-guided saccades, in the horizontal plane, was due to mislocalization at the time that the target flashed, misrepresentation of the trajectory of the pursuit eye movement during the memory period, or both. 8. The magnitude of the saccadic error, both with and without corrections made in darkness, was mislocalized by approximately 30% of the displacement of the background at the time that the target flashed. The magnitude of the saccadic error also was influenced by net movement of the background during the memory period, corresponding to approximately 25% of net background movement for the initial saccade and approximately 13% for the final eye position achieved in darkness. 9. We formulated simple linear models to test specific hypotheses about which combinations of signals best describe the observed saccadic amplitudes. We tested the possibilities that the brain made an accurate memory of target location and a reliable representation of the eye movement during the memory period, or that one or both of these was corrupted by the illusory visual stimulus. Our data were best accounted for by a model in which both the working memory of target location and the internal representation of the horizontal eye movements were corrupted by the illusory visual stimulus. We conclude that extraretinal signals played only a minor role, in comparison with visual estimates of the direction of gaze, in planning eye movements to remembered targ.

Clinical Trial↗

Cloud-to-Ground Lightning Estimates Derived from SSMI Microwave Remote Sensing and NLDN

Lightning observations are collected using ground-based and satellite-based sensors. The National Lightning Detection Network (NLDN) in the United States uses multiple ground sensors to triangulate the electromagnetic signals created when lightning strikes the Earth's surface. Satellite-based lightning observations have been made from 1998 to present using the Lightning Imaging Sensor (LIS) on the NASA Tropical Rainfall Measuring Mission (TRMM) satellite, and from 1995 to 2000 using the Optical Transient Detector (OTD) on the Microlab-1 satellite. Both LIS and OTD are staring imagers that detect lightning as momentary changes in an optical scene. Passive microwave remote sensing (85 and 37 GHz brightness temperatures) from the TRMM Microwave Imager (TMI) has also been used to quantify characteristics of thunderstorms related to lightning. Each lightning detection system has fundamental limitations. TRMM satellite coverage is limited to the tropics and subtropics between 38 deg N and 38 deg S, so lightning at the higher latitudes of the northern and southern hemispheres is not observed. The detection efficiency of NLDN sensors exceeds 95%, but the sensors are only located in the USA. Even if data from other ground-based lightning sensors (World Wide Lightning Location Network, the European Cooperation for Lightning Detection, and Canadian Lightning Detection Network) were combined with TRMM and NLDN, there would be enormous spatial gaps in present-day coverage of lightning. In addition, a globally-complete time history of observed lightning activity is currently not available either, with network coverage and detection efficiencies varying through the years. Previous research using the TRMM LIS and Microwave Imager (TMI) showed that there is a statistically significant correlation between lightning flash rates and passive microwave brightness temperatures. The physical basis for this correlation emerges because lightning in a thunderstorm occurs where ice is first present in the cloud and electric charge separation occurs. These ice particles efficiently scatter the microwave radiation at the 85 and 37 GHz frequencies, thus leading to large brightness temperature depressions. Lightning flash rate is related to the total amount of ice passing through the convective updraft regions of thunderstorms. Confirmation of this relationship using TRMM LIS and TMI data, however, remains constrained to TRMM observational limits of the tropics and subtropics. Satellites from the Defense Meteorology Satellite Program (DMSP) have global coverage and are equipped with passive microwave imagers that, like TMI, observe brightness temperatures at 85 and 37 GHz. Unlike the TRMM satellite, however, DMSP satellites do not have a lightning sensor, and the DMSP microwave data has never been used to derive global lightning. In this presentation, a relationship between DMSP Special Sensor Microwave Imager (SSMI) data and ground-based cloud-to-ground (CG) lightning data from NLDN is investigated to derive a spatially complete time history of CG lightning for the USA study area. This relationship is analogous to the established using TRMM LIS and TMI data. NLDN has the most spatially and temporally complete CG lightning data for the USA, and therefore provides the best opportunity to find geospatially coincident observations with SSMI sensors. The strongest thunderstorms generally have minimum 85 GHz Polarized Corrected brightness Temperatures (PCT) less than 150 K. Archived radar data was used to resolve the spatial extent of the individual storms. NLDN data for that storm spatial extent defined by radar data was used to calculate the CG flash rate for the storm. Similar to results using TRMM sensors, a linear model best explained the relationship between storm-specific CG flash rates and minimum 85 GHz PCT. However, the results in this study apply only to CG lightning. To extend the results to weaker storms, the probability of CG lightning (instead of the flash rate) was calculated for storms having 85 GHz PCT greater than 150 K. NLDN data was used to determine if a CG strike occurred for a storm. This probability of CG lightning was plotted as a function of minimum 85 GHz PCT and minimum 37 GHz PCT. These probabilities were used in conjunction with the linear model to estimate the CG flash rate for weaker storms with minimum 85 GHz PCTs greater than 150 K. Results from the investigation of CG lightning and passive microwave radiation signals agree with the previous research investigating total lightning and brightness temperature. Future work will take the established relationships and apply them to the decades of available DMSP data for the USA to derive a map of CG lightning flash rates. Validation of this method and uncertainty analysis will be done by comparing the derived maps of CG lightning flash rates against existing NLDN maps of CG lightning flash rates.

Winesett, Thomas↗

The Origin of Hot Subluminous Horizontal-Branch Stars in Omega Centauri and NGC 2808

Hot subluminous stars lying up to 0.7 mag below the extreme horizontal branch (EHB) are found in the ultraviolet color-magnitude diagrams of both omega Cen (DCruz et.al. 2000) and NGC 2808 (Brown et al. 2001). In order to investigate the origin of these subluminous stars, we have constructed a detailed set of evolutionary sequences that follow the evolution of low-mass stars continuously from the zero-age main sequence through the helium-core flash to the HB for a wide range in the mass loss along the red-giant branch (RGB). Stars with the largest mass loss evolve off the RGB to high effective temperatures before igniting helium in their cores (Castellani & Castellani 1993). Our results indicate that the location of the subluminous EHB stars, as well as the high temperature gap along the EHB of NGC 2808, can be explained if these stars undergo a late helium-core flash while descending the white-dwarf cooling curve. Under these conditions the convection zone produced by the main helium flash will penetrate into the stellar envelope, thereby mixing most, if not all, of the envelope hydrogen into the hot helium-burning interior, where it is rapidly consumed (Sweigart 1997). This phenomenon is analogous to the "born-again" scenario for producing hydrogen-deficient stars following a very late helium-shell flash. This "flash mixing" of the envelope during a late helium-core flash greatly enhances the envelope helium and carbon abundances and, as a result, leads to a discontinuous increase in the HB effective temperature. We argue that the hot HB gap observed in NGC 2808 is associated with this theoretically predicted dichotomy in the HB properties. Using new helium- and carbon-rich stellar atmospheres, we show that the changes in the envelope abundances due to flash mixing will suppress the ultraviolet flux in the spectra of hot EHB stars. We suggest that such changes in the emergent spectral energy distribution are primarily responsible for explaining the hot subluminous EHB stars in omega Cen and NGC 2808. Moreover, we demonstrate that models without flash mixing lie, at most, only approximately 0.1 mag below the EHB, and hence fail to explain the observations.

Sweigart, Allen V.↗

The Origin of Hot Subluminous Horizontal-Branch Stars in (omega) Centauri and NGC 2808

Hot subluminous stars lying up to 0.7 mag below the extreme horizontal branch (EHB) are found in the ultraviolet (UV) color magnitude diagrams of both (omega) Cen and NGC 2808. In order to explore the evolutionary status of these subluminous stars, we have evolved a set of low-mass stars continuously from the main sequence through the helium-core flash to the HB (horizontal branch) for a wide range in the mass loss along the red-giant branch (RGB). Stars with the largest mass loss evolve off the RGB to high effective temperatures before igniting helium in their cores. Our results indicate that the subluminous EHB stars, as well as the gap within the EHB of NGC 2808, can be explained if these stars undergo a late helium-core flash while descending the white-dwarf cooling curve. Under these conditions the convection zone produced by the helium flash will penetrate into the stellar envelope, thereby mixing most, if not all, of the envelope hydrogen into the hot helium-burning interior, where it is rapidly consumed. This phenomenon is analogous to the 'born-again' scenario for producing hydrogen-deficient stars following a very late helium-shell flash. This 'flash mixing' of the stellar envelope greatly enhances the envelope helium and carbon abundances and, as a result, leads to a discontinuous jump in the HB effective temperature. We argue that the EHB gap in NGC 2808 is associated with this theoretically predicted dichotomy in the HB morphology. Using new helium- and carbon-rich stellar atmospheres, we show that these changes in the envelope abundances of the flash-mixed stars will suppress the UV flux by the amount needed to explain the hot subluminous EHB stars in (omega) Cen and NGC 2808. Moreover, we demonstrate that models without flash mixing lie, at most, only approximately 0.1 mag below the EHB, and hence fail to explain the observations. Flash mixing may also provide a new evolutionary channel for producing the high gravity, helium-rich sdO and sdB stars.

Sweigart, Allen V.↗

A New Formation Mechanism for the Hottest Horizontal-Branch Stars

Hot subluminous stars lying up to 0.7 mag below the extreme horizontal branch (EHB) are found in the ultraviolet color-magnitude diagrams (CMDs) of both omega Cen and NGC 2808. In order to investigate the origin of these subluminous stars, we have constructed a detailed set of evolutionary sequences that follow the evolution of low-mass stars continuously from the zero-age main sequence through the helium-core flash to the HB for a wide range in the mass loss along the red-giant branch (RGB). Stars with the largest mass loss evolve off the RGB to high effective temperatures before igniting helium in their cores. Our results indicate that the subluminous EHB stars, as well as the high temperature gap along the EHB of NGC 2808, can be explained if these stars undergo a late helium-core flash while descending the white-dwarf cooling curve. Under these conditions the convection zone produced by the main helium flash will penetrate into the stellar envelope, thereby mixing most, if not all, of the envelope hydrogen into the hot helium-burning interior, where it is rapidly consumed. This phenomenon is analogous to the 'born-again' scenario for producing hydrogen-deficient stars following a very late helium-shell flash. This 'flash mixing' of the envelope during a late helium-core flash greatly enhances the envelope helium and carbon abundances and, as a result, leads to a discontinuous increase in the HB effective temperature. We argue that the hot HB gap observed in NGC 2808 is associated with this theoretically predicted dichotomy in the RB properties. Using new helium- and carbon-rich stellar atmospheres, we show that the changes in the envelope abundances due to flash mixing will suppress the ultraviolet flux in the spectra of hot EHB stars. We suggest that such changes in the emergent spectral energy distribution are primarily responsible for explaining the hot subluminous EHB stars in omega Cen and NGC 2808. Moreover, we demonstrate that models without flash mixing lie, at most, only approximately 0.1 mag below the EHB, and hence fail to explain the observations.

Sweigart, Allen V.↗

Effects of Deep Convection on Atmospheric Chemistry

This presentation will trace the important research developments of the last 20+ years in defining the roles of deep convection in tropospheric chemistry. The role of deep convection in vertically redistributing trace gases was first verified through field experiments conducted in 1985. The consequences of deep convection have been noted in many other field programs conducted in subsequent years. Modeling efforts predicted that deep convection occurring over polluted continental regions would cause downstream enhancements in photochemical ozone production in the middle and upper troposphere due to the vertical redistribution of ozone precursors. Particularly large post-convective enhancements of ozone production were estimated for convection occurring over regions of pollution from biomass burning and urban areas. These estimates were verified by measurements taken downstream of biomass burning regions of South America. Models also indicate that convective transport of pristine marine boundary layer air causes decreases in ozone production rates in the upper troposphere and that convective downdrafts bring ozone into the boundary layer where it can be destroyed more rapidly. Additional consequences of deep convection are perturbation of photolysis rates, effective wet scavenging of soluble species, nucleation of new particles in convective outflow, and the potential fix stratosphere-troposphere exchange in thunderstorm anvils. The remainder of the talk will focus on production of NO by lightning, its subsequent transport within convective clouds . and its effects on downwind ozone production. Recent applications of cloud/chemistry model simulations combined with anvil NO and lightning flash observations in estimating NO Introduction per flash will be described. These cloud-resolving case-study simulations of convective transport and lightning NO production in different environments have yielded results which are directly applicable to the design of lightning parameterizations for global chemical transport models. The range of mean values (factor of 3) of NO production per flash (or per meter of lightning channel length) that have been deduced from the model will be shown and compared with values of production in the literature that have been deduced using other methods, Results show that on a per flash basis, IC flashes are nearly as productive of NO as CG flashes. When combined with the global flash rate of 44 flashes per second from NASA's Optical Transient Detector (OTD) measurements, these estimates and the results from other techniques yield global NO production rates of 2-9 TgN/year. Vertical profiles of lightning NOx mass at the end of the 3-D storm simulations have been summarized to yield suggested profiles for use in global models. Simulations of the photochemistry over the 24 hours following a storm have been performed to determine the additional ozone production which can be attributed to lightning NO.

Pickering, Kenneth E.↗