Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Lifelong population connectivity between large rivers and their tributaries: A case study of shovelnose sturgeon from the Mississippi and Wisconsin rivers

Fishes that depend on large–river habitats have declined in many regions due to human alteration of both mainstems and tributaries. Conserving these species is often complicated by their dependence on long–distance movements to complete their life cycle, but the location of key habitats is difficult to assess across multiple life history stages. Movement of large–river fishes between mainstems and major tributaries is commonly observed, but the role of these exchanges at the population level is uncertain. We used shovelnose sturgeon ( Scaphirhynchus platorynchus ) as a case study for assessing the lifelong spatial ecology of large–river fishes. Fin ray microchemistry data indicate that shovelnose sturgeon from the Mississippi and Wisconsin rivers represent a unified population that relies on connections among multiple large–river habitats throughout life history. The tributary serves as an important spawning area, but fin ray chemistry data suggest larvae subsequently drift downstream to nursery habitats in the mainstem; an assertion that is supported by extensive field survey data. Our analyses underscore the lifelong importance of connections within river networks for maintaining viable populations of this, and likely other large–river species that have been documented to use tributary habitats. Furthermore, these findings support a metapopulation perspective on species that depend on large–river habitats, many of which are now highly altered and fragmented. For shovelnose sturgeon and species with similar life history, protecting or restoring linkages between mainstem rivers and their tributaries should be a conservation priority.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of Acclimation on Poststocking Dispersal and Physiological Condition of Age-1 Pallid Sturgeon

A propagation program for pallid sturgeon Scaphirhynchus albus in the upper Missouri River was implemented by the U. S. Fish and Wildlife Service in 1997. Preliminary research indicated that many hatchery-reared pallid sturgeon were experiencing significant downstream poststocking dispersal, negatively affecting their recruitment. Therefore, the objective of this study was to evaluate the effects of acclimation to flow and site-specific physicochemical water conditions on poststocking dispersal and physiological condition of age-1 pallid sturgeon. Fish from three acclimation treatments were radio-tagged, released at two locations (Missouri River and Marias River), and monitored using passive telemetry stations. Marias treatment was acclimated to flow and site-specific physicochemical conditions, Bozeman treatment was acclimated to flow only, and traditional treatment had no acclimation (reared under traditional protocol). During both years fish released in the Missouri River dispersed less than fish released in the Marias River. In 2005, Marias treatment dispersed less and nearly twice as many fish remained in the Missouri River reach than traditional treatment. In 2006, pallid sturgeon dispersed similarly among treatments and fish remaining in the Missouri River reach were similar among all treatments. Differences in poststocking dispersal between years may be related to fin curl. Fin curl was present in all fish in 2005 and 27% of the fish in 2006. Pallid sturgeon from all treatments in both years had a greater affinity for the lower reaches of the Missouri River than the upper reaches. Thus, habitat at release site influenced poststocking dispersal more than acclimation treatment. No difference was observed in relative growth rate among treatments in 2006. However, acclimation to flow (i.e., exercise conditioning) may reduce liver fat content. Acclimation conditions used in this study may not benefit pallid sturgeon unless physiological maladies are present. Further, natural resource agencies need to consider stocking location carefully to reduce poststocking dispersal.

54 ENVIRONMENTAL SCIENCES↗

Subcooled Boiling Heat Transfer for Cooling of Power Electronics in Hybrid Electric Vehicles

At present, single-phase liquid, forced convection cooled heat sinks with fins are used to cool power electronics in hybrid electric vehicles (HEVs). Although use of fins in the cooling channels increases heat transfer rates considerably, a second low-temperature radiator and associated pumping system are still required in HEVs. This additional cooling system adds weight and cost while decreasing the efficiency of HEVs. With the objective of eliminating this additional low-temperature radiator and pumping system in HEVs, an alternative cooling technology, subcooled boiling in the cooling channels, was investigated in the present study. Numerical heat transfer simulations were performed using subcooled boiling in the power electronics cooling channels with the coolant supplied from the existing main engine cooling system. Results show that this subcooled boiling system is capable of removing 25% more heat from the power electronics than the conventional forced convection cooling technology, or it can reduce the junction temperature of the power electronics at the current heat removal rate. With the 25% increased heat transfer option, high heat fluxes up to 250 W/cm(2) (typical for wideband-gap semiconductor applications) are possible by using the subcooled boiling system.

Heat transfer simulations↗

Numbering-Up of Microscale Devices for Megawatt-Scale Supercritical Carbon Dioxide Concentrating Solar Power Receivers

Concentrated solar power (CSP) plants have the potential to reduce the consumption of nonrenewable resources and greenhouse gas emissions in electricity production. In CSP systems, a field of heliostats focuses solar radiation on a central receiver, and energy is then transferred to a thermal power plant at high temperature. However, maximum receiver surface fluxes are low (30–100 W cm -2 ) with high thermal losses, which has contributed to the limited market penetration of CSP systems. Recently, small (~4 cm 2 ), laminated micro pin-fin devices have shown potential to achieve concentrated surface fluxes over 100 W cm -2 using supercritical CO 2 as the working fluid. The present study explores the feasibility of using these microscale unit cells as building blocks for a megawatt-scale (250 MW thermal) open solar receiver through a numbering-up approach, where multiple microscale unit cell devices are connected in parallel. A multiscale model of the full-scale central receiver is developed. The model consists of interconnected unit cell and module level (i.e., multiple unit cells in parallel) submodels which predict local performance of the central receiver. Each full-scale receiver consists of 3000 micro pin-fin unit cells divided into 250 modules. The performance of three different full-scale receivers is simulated under representative operating conditions. The results show that the microscale unit cells have the potential to be numbered up to megawatt applications while providing high heat flux and thermal efficiency. At the design incident flux and surface emissivity, a global receiver efficiency of approximately 90% when heating sCO 2 from 550 °C to 650 °C at an average incident flux of 110 W cm -2 can be achieved.

14 SOLAR ENERGY↗

High Power Density Thermal Energy Storage With Phase Change Material in Enhanced Compact Heat Exchangers

Abstract Performance of a novel ultracompact thermal energy storage (TES) heat exchanger, designed as a microchannel finned-tube exchanger is presented. With water as the heating–cooling fluid in the microchannels, a salt hydrate phase change material (PCM), lithium nitrate trihydrate (LiNO3 · 3H2O), was encased on the fin side. To establish the hypothesis that small-length-scale encasement (<3 mm) of PCM substantially enhances heat transfer to yield very high power-density energy storage, heat exchanger designs with 10 and 24 fins/inch were considered. They were subjected to thermal cycling, or repeated heating (melting) and cooling (freezing), with inlet fluid flow mimicking diurnal variation between 42 °C and 25 °C (representing typical arid-region conditions) over an accelerated time period. By employing salt self-seeding to obviate subcooling during cooling or recrystallization, the TES was found to exhibit stable long-term (100 heating–cooling cycles) operation with very high PCM-side heat transfer coefficients (∼100–500 W/m2 K) and storage power density (∼160–175 kW/m3). In fact, with optimization of heating–cooling fluid flowrate for given charging–discharging time period and exchanger size, power density >300 kW/m3 can be achieved. The results clearly establish that highly compact heat exchangers used as TES units can provide very high-performance alternatives to conventional ones.

Engineering↗

Multi-Scale Thermal Analysis for Design of SiC-Based Medium Voltage Motor Drive: Preprint

This paper describes a multi-scale thermal analysis approach for the design of an air-cooled 1.7-kV SiC MOSFET-based medium-voltage variable-speed motor drive. The National Renewable Energy Laboratory supported the project objectives by providing thermal management design support to the project partner The Ohio State University (OSU). The scope of the models and limited resources required efficient and flexible thermal models to be developed. Two modeling techniques are described that significantly reduced model run time and enabled more complex models to be run faster while retaining needed accuracy. The first technique uses the effectiveness-NTU method to extract convection boundary conditions from a computational fluid dynamics (CFD) model that can be applied to a fast-running finite element analysis model. The second is a porous media technique that enables system-level CFD simulations that incorporate effects from heat exchangers (e.g., pin fin heat sinks) that run in a fraction of the time required for fully resolved CFD simulations. The multi-scale approach to the thermal analysis enabled fast and accurate simulation for the converter design ranging from the die level up to the full system with 36 submodules. The modeling results were validated against experimental data from system tests performed by OSU.

DIRECT ENERGY CONVERSION↗

Prediction of plasma-induced damage distribution during silicon nitride etching using advanced three-dimensional voxel model

The authors modeled SiN film etching with hydrofluorocarbon (CH{sub x}F{sub y}/Ar/O{sub 2}) plasma considering physical (ion bombardment) and chemical reactions in detail, including the reactivity of radicals (C, F, O, N, and H), the area ratio of Si dangling bonds, the outflux of N and H, the dependence of the H/N ratio on the polymer layer, and generation of by-products (HCN, C{sub 2}N{sub 2}, NH, HF, OH, and CH, in addition to CO, CF{sub 2}, SiF{sub 2}, and SiF{sub 4}) as ion assistance process parameters for the first time. The model was consistent with the measured C-F polymer layer thickness, etch rate, and selectivity dependence on process variation for SiN, SiO{sub 2}, and Si film etching. To analyze the three-dimensional (3D) damage distribution affected by the etched profile, the authors developed an advanced 3D voxel model that can predict the time-evolution of the etched profile and damage distribution. The model includes some new concepts for gas transportation in the pattern using a fluid model and the property of voxels called “smart voxels,” which contain details of the history of the etching situation. Using this 3D model, the authors demonstrated metal–oxide–semiconductor field-effect transistor SiN side-wall etching that consisted of the main-etch step with CF{sub 4}/Ar/O{sub 2} plasma and an over-etch step with CH{sub 3}F/Ar/O{sub 2} plasma under the assumption of a realistic process and pattern size. A large amount of Si damage induced by irradiated hydrogen occurred in the source/drain region, a Si recess depth of 5 nm was generated, and the dislocated Si was distributed in a 10 nm deeper region than the Si recess, which was consistent with experimental data for a capacitively coupled plasma. An especially large amount of Si damage was also found at the bottom edge region of the metal–oxide–semiconductor field-effect transistors. Furthermore, our simulation results for bulk fin-type field-effect transistor side-wall etching showed that the Si fin (source/drain region) was directly damaged by high energy hydrogen and had local variations in the damage distribution, which may lead to a shift in the threshold voltage and the off-state leakage current. Therefore, side-wall etching and ion implantation processes must be carefully designed by considering the Si damage distribution to achieve low damage and high transistor performance for complementary metal–oxide–semiconductor devices.

42 ENGINEERING↗

Sources and levels of ambient ocean sound near the antarctic peninsula

Arrays of hydrophones were deployed within the Bransfield Strait and Scotia Sea (Antarctic Peninsula region) from 2005 to 2009 to record ambient ocean sound at frequencies of up to 125 and 500 Hz. Icequakes, which are broadband, short duration signals derived from fracturing of large free-floating icebergs, are a prominent feature of the ocean soundscape. Icequake activity peaks during austral summer and is minimum during winter, likely following freeze-thaw cycles. Iceberg grounding and rapid disintegration also releases significant acoustic energy, equivalent to large-scale geophysical events. Overall ambient sound levels can be as much as ~10–20 dB higher in the open, deep ocean of the Scotia Sea compared to the relatively shallow Bransfield Strait. Noise levels become lowest during the austral winter, as sea-ice cover suppresses wind and wave noise. Ambient noise levels are highest during austral spring and summer, as surface noise, ice cracking and biological activity intensifies. Vocalizations of blue ( Balaenoptera musculus ) and fin ( B. physalus ) whales also dominate the long-term spectra records in the 15–28 and 89 Hz bands. Blue whale call energy is a maximum during austral summer-fall in the Drake Passage and Bransfield Strait when ambient noise levels are a maximum and sea-ice cover is a minimum. Fin whale vocalizations were also most common during austral summer-early fall months in both the Bransfield Strait and Scotia Sea. The hydrophone data overall do not show sustained anthropogenic sources (ships and airguns), likely due to low coastal traffic and the typically rough weather and sea conditions of the Southern Ocean.

54 ENVIRONMENTAL SCIENCES↗

CIRCULATING MOVING BED COMBUSTION PROOF OF CONCEPT

Circulating Moving Bed (CMB) combustion technology has its roots in traditional circulating fluidized bed technology and involves a novel method of solid fuel combustion and heat transfer. CMB technology represents a step change in improved performance and cost relative to conventional PC and FBC boilers. The CMB heat exchanger preheats the energy cycle working fluid, steam or air, to the high temperature levels required in systems for advanced power generation. Unique features of the CMB are the reduction of the heat transfer surfaces by about 60% as a result of the enhanced heat transfer rates, flexibility of operation, and about 30% lower cost over existing technology. The CMB Phase I project ran from July 2001 through March 2003. Its objective was to continue development of the CMB technology with a series of proof of concept tests. The tests were conducted at a scale that provided design data for scale up to a demonstration plant. These objectives were met by conducting a series of experiments in ALSTOM Power’s Multi-use Test Facility (MTF). The MTF was modified to operate under CMB conditions of commercial interest. The objective of the tests were to evaluate gas-to-solids heat transfer in the upper furnace, assess agglomeration in the high temperature CMB bubbling bed, and evaluate solids-to-tube heat transfer in the moving bed heat exchanger. The Phase I program results showed that there are still some significant technical uncertainties that needed to be resolved before the technology can be confidently scaled up for a successful demonstration plant design. Work remained in three primary areas: • scale up of gas to solid heat transfer • high temperature finned surface design • the overall requirements of mechanical and process design. The CMB Phase II workscope built upon the results of Phase I and specifically addressed the remaining technical uncertainties. It included a scaled MTF heat transfer test to provide the necessary data to scale up gas-to-solids heat transfer. A stress test rig was built and tested to provide validation data for a stress model needed to support high temperature finned surface design. Additional cold flow model tests and MTF tests were conducted to address mechanical and process design issues. This information was then used to design and cost a commercial CMB design concept. Finally, the MBHE was reconfigured into a slice arrangement and tested for an extended duration at a commercial CFB plant.

42 ENGINEERING↗

Development of external and neutrally buoyant acoustic transmitters for turbine passage evaluation

Recent studies show transmitters surgically implanted into juvenile salmonids, for the purposes of estimating survival of fish passing through turbines, increases the risk of injury and mortality due to the presence of the tag and exposure to rapid turbine pressure changes. Neutrally buoyant external tags may instead be used to eliminate this bias. However, the externally tagged fish could be affected by other factors such as shear and turbulence which may also bias survival estimates. Studies have been conducted to examine the influence of shear and turbulence on non-tagged juvenile salmonids, however, tests have never been conducted in the laboratory or field to determine the influence of shear and turbulence on retention and injury related to attachment of external transmitters. We designed and manufactured two different configurations of neutrally buoyant (nearly zero g weight in water) external transmitters: Type A and Type B. The Type A transmitters weigh approximately 0.60 g in air and are attached to fish using two sutures anterior to the dorsal fin. The Type B transmitters weigh approximately 0.83 g in air and consist of battery part and transducer part with both parts neutrally buoyant. They are attached to both sides of the dorsal fin using two enamel coated 25 gauge magnet wires. This study provides a broad approach using evaluation measures such as holding, swimming performance, shear, turbulence, rapid decompression exposures, and predation to determine the efficacy of using neutrally buoyant external transmitters to estimate survival of juvenile salmonids passing through turbines. Preliminary results show the Type A design is a viable design for turbine passage evaluation and is being planned for field deployment in the near future.

Advanced turbine↗

Demonstration of a Variable Phase Turbine Power System for Low Temperature Geothermal Resources

A variable phase turbine assembly will be designed and manufactured having a turbine, operable with transcritical, two-phase or vapor flow, and a generator – on the same shaft supported by process lubricated bearings. The assembly will be hermetically sealed and the generator cooled by the refrigerant. A compact plate-fin heat exchanger or tube and shell heat exchanger will be used to transfer heat from the geothermal fluid to the refrigerant. The demonstration turbine will be operated separately with two-phase flow and with vapor flow to demonstrate performance and applicability to the entire range of low temperature geothermal resources. The vapor leaving the turbine is condensed in a plate-fin refrigerant condenser. The heat exchanger, variable phase turbine assembly and condenser are all mounted on single skids to enable factory assembly and checkout and minimize installation costs. The system will be demonstrated using low temperature (237F) well flow from an existing large geothermal field. The net power generated, 1 megawatt, will be fed into the existing power system at the demonstration site. The system will demonstrate reliable generation of inexpensive power from low temperature resources. The system will be designed for mass manufacturing and factory assembly and should cost less than $\$$1,200/kWe installed, when manufactured in large quantities. The estimated cost of power for 300F resources is predicted to be less than 5 cents/kWh. This should enable a substantial increase in power generated from low temperature geothermal resources.

15 GEOTHERMAL ENERGY↗

Status Report on the Water-Based NSTF RCCS Capability: Preparations and Design for the Transformation of the Natural Convection Shutdown Heat Removal Test Facility (NSTF) From Air to Water-based Cooling

The following report provides an overview of the current status of the water-based transformation, including details of the design, geometry, and fabrication of the test section and network piping, for the ½ scale water-based NSTF program at Argonne National Laboratory. In early FY2015, efforts towards a water-based design began in parallel with on-going air-based work, and began by identifying top level objectives of the transformation. Scaling studies and preparation tasks with computational modeling were carried out to guide the design decisions, minimize distortions, and ensure relevant data among scales. This entailed close collaboration with AREVA, whose water-based RCCS (included as part of their 625 MWt SC-HTGR) served as the primary design basis for incorporation into the NSTF. A literature review of previous works was made, with an emphasis placed on similar facilities, relevance to passive decay heat removal, and details pertaining to two-phase flow and measurement techniques. The study focused on input from key designers and a thermal analysis of existing cooling panels (e.g. at TAMU and UW-Madison) and two proposed AREVA cooling panels. A base case was used as a reference point for parametric studies of effects from varying tube spacing (pitch), tube diameter, fin thickness, and materials. Then, a structural analysis was performed to ensure safe material stresses during high temperature operation. Details of the pipe network geometry and guidelines for design of the water storage tank are finally presented, followed by engineering drawings in the appendix. The results of this study have identified a suitable configuration to support both the ANL/DOE project goals and the DOE vision to provide AREVA with data suitable for characterizing the RCCS of their full scale HTGR design. The dimensions were not selected for optimal RCCS performance, but instead to serve as a representative yet bounding configuration for future implementation into a full scale design. Scaling distortions are unavoidable; however, they can be accurately predicted based on earlier works of derived similarity solutions. Flexibility remained a primary design philosophy, and will allow the test facility to easily accommodate future alterations. The final design for the test section and network piping is as follows: riser tubes: 1.5” Schedule 160, 5.91” (150-mm) pitch, 304L stainless, heat transfer panels: 5/16” plates, 4.01” (102-mm) width, full penetration weld to risers, 304L stainless, split into 4 panels per riser separated by horizontal 1/8” gaps, test section: Eight (x8) riser tubes and nine (x9) heat transfer panels, fabricated into banks of two (x2) riser tubes and three (x3) fins, joined to form single section, and network geometry: 4.0” Schedule 40, 304L stainless. Details of the water storage tank will reflect competing effects such as thermal hydraulic phenomena during single and two-phase operation. These considerations include mixing during single-phase jet penetration, condensation of rising bubbles during two-phase discharge, bubble entrainment into the liquid outlet, and liquid carry-over into the steam outlet.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development of HPWH System Model, Using All Microchannel Heat Exchangers

In this report, 24-hour energy factor (EF) and first-hour draw rating (FHR) simulations were conducted on two heat pump water heater systems (HPWHs), one using a fin-and-tube evaporator and wrapped-tank condenser coil with D-shape tubes, and the other using a micro-channel evaporator and wrapped-tank condenser coil with microchannel tubes. Alternative refrigerants as drop-in replacements of R-134a were evaluated, including R-1234yf, R-1234ze(E), propane (R-290), R-450A and R-513A. The results are summarized below: 1.Microchannel heat exchangers can decrease the system charge down to 30% relative to fin-and-tube evaporator and wrapped-tank D tubes.2.Having the same contact surface area to the water tank and evaporator frontal flow area, the system using microchannel heat exchangers (MHXs) results in 5% efficiency degradation. Due to the very small cross-sectional flow area of a microchannel tube, MHXs tend to have multiple parallel tubes to restrict the refrigerant pressure drop. The parallel pattern can’t utilize the water temperature stratification as effectively as the D-shape tubes, which are arranged in one or two circuits and counter flow to the water stratification. 3.Refrigerant drop-in system simulations were conducted for R-1234yf, R-1234ze(E), propane, R450A and R513A in comparison to R-134a. Among the alternatives, propane has the largest volumetric capacity, which results in shortest HPWH run time and highest first-hour rating. Propane leads to the smallest energy factor because its largest volumetric capacity overloads the heat exchangers. R-1234ze(E) has the smallest volumetric capacity, highest energy factor, but smallest first-hour rating. R-1234yf, R-450A and R-513A achieve similar performance indices as R-134a. 4.Propane requires the least refrigerant mass (45% relative to R-134a). If a wrapped-tank microchannel condenser and microchannel evaporator are used, the required system charge can be limited below 150 grams, which makes it feasible to use propane for domestic HPWH.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Additive Manufacturing of Energy Harvesting Material System for Active Wireless MEMS Sensors

Combustion systems make up a large sum of the world’s yearly energy production despite advances in renewable energy sources. Precise control of pressure and temperature in combustion chambers allows for lower carbon emissions, and overall higher efficiency. Wireless temperature and pressure sensors are critical for the operation of combustion chambers. Energy harvesters have emerged as a viable way to power wireless sensors when heat and mechanical energy are available. Lithium niobate (LNB), barium titanate (BTO), and lead zirconate titanate (PZT) pyroelectric ceramics were studied and fabricated through additive manufacturing (AM) for use as energy harvesting structures in combustion environments. The electric power generation potential of LNB and PZT ceramics was studied by varying the temperature from 50 to 60 °C and by introducing cyclic compression loads of 2000 N amplitude. It was found that thermal energy conversion had the highest output of 500 nW and that combined thermal and mechanical conversion did not increase the harvesting potential because of the competing contributions of both effects. Powder bed and slurry extrusion AM methods were used to fabricate BTO and PZT ceramic structures. Optimization of the powder-based binder jetting method produced BTO ceramics with a relative density of 36.77% a piezoelectric coefficient of 153 pC/N. The density of the ceramics increased up to 56% when increasing the saturation of binder in the powder to because of liquid phase sintering. Finally, PZT structures were manufactured through AM and fin features were added to the design to enhance the heat transfer along the material. The harvested power density of the flat samples was 3.643 μW/cm 3 and of the finned samples was 3.034 μW/cm3. This research paves the ways for the development of self-powered wireless sensors in critical areas of operation such as combustion.

01 COAL, LIGNITE, AND PEAT↗

Technologies for Enhanced Condensation in sCO 2 Power Cycles

The direct fired supercritical carbon dioxide power cycle has higher efficiency, compact machinery footprint, and is resilient under transient operation. It has been shown that improving the cycle main cooler significantly improves performance, including increased cycle efficiency, decreased cost of electricity and decreased cooler outlet temperatures. One way to improve this process is through enhanced condensation techniques and management of condensation fluid. This manuscript provides an overview of active and passive enhanced condensation technologies, with a focus on the passive approaches. compared to passive approaches, active approaches can have higher heat transfer enhancement, but the additional power and infrastructure can be problematic. The passive approaches identified include microfins (helical and herringbone), corrugated tubing, dimpled tubing and pin fins. After comparison it is found that the microfin geometry has the best performance characteristics followed by the additively manufactured pin fins. It is noted that current literature around additively manufactured enhancements is lacking, and investigation of conventional as well as novel geometries fabricated in this manner may be worth further investigation. Benchmark correlations for these geometries are identified and their limitations outlined. For further investigation, a matrix of test articles is presented for possible experimentation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular Hydronic Room Conditioning System

This project presents the development and validation of high-fidelity numerical models for fin-tube heat exchangers to enable accurate performance prediction and informed design optimization. The modeling framework integrates detailed geometric specifications, thermophysical property data, and system-level constraints to simulate the heat exchanger’s behavior under a range of operating conditions. The model is calibrated using real-world product specifications and validated against experimental data collected from controlled cooling and heating tests. In cooling mode, the model captures the overall trends in capacity and outlet air temperature but tends to underpredict latent effects, especially at lower air flow rates. In heating mode, the simulation consistently overestimates both the thermal capacity and outlet air temperature, indicating the need for refinement in air-side heat transfer assumptions. Despite these deviations, the model provides a solid foundation for optimization, allowing key design variables to be tuned within physical and performance-based constraints. This research advances the ability to simulate, validate, and optimize fin tube heat exchanger designs with greater confidence and efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a High-Efficiency Hybrid Dry Cooler System for sCO 2 Power Cycles in CSP Applications

This project addressed a major gap in supercritical CO 2 (sCO 2 ) power cycle research by focusing on the pre-cooler, a component that had received little attention despite its significant impact on cycle efficiency and plant economics. The team developed a compact dry cooler using brazed/diffusion-bonded microchannel passages paired with formed air-side fins, advancing the technology from TRL-2 toward commercial readiness. Compared to conventional fin-tube coolers, the design cuts installation footprint by roughly half for 10+ MWth systems while achieving better heat transfer and lower approach temperatures, translating into a projected LCOE reduction from 6.04 ¢/kWh to between 5.85 and 5.94 ¢/kWh. While fabrication of an aluminum MW-scale prototype revealed brazing and sealing challenges at larger scales, lessons learned informed a subsequent 1 MWth unit that was successfully built and delivered for integration into Sandia's Gen3 Particle Pilot Plant, advancing the technology to TRL-7 with a path toward TRL-8 pending successful testing.

30 DIRECT ENERGY CONVERSION↗

Smolt Monitoring at the Head of Lower Granite Reservoir and Lower Granite Dam, 2002 Annual Report.

This project monitored the daily passage of Chinook salmon Oncorhynchus tshawytscha, steelhead trout O. mykiss, and sockeye salmon smolts O. nerka during the 2002 spring out-migration at migrant traps on the Snake River and Salmon River. In 2002 fish management agencies released significant numbers of hatchery Chinook salmon and steelhead trout above Lower Granite Dam that were not marked with a fin clip or coded-wire tag. Generally, these fish were distinguishable from wild fish by the occurrence of fin erosion. Total annual hatchery Chinook salmon catch at the Snake River trap was 11.4 times greater in 2002 than in 2001. The wild Chinook catch was 15.5 times greater than the previous year. Hatchery steelhead trout catch was 2.9 times greater than in 2001. Wild steelhead trout catch was 2.8 times greater than the previous year. The Snake River trap collected 3,996 age-0 Chinook salmon of unknown rearing. During 2002, the Snake River trap captured 69 hatchery and 235 wild/natural sockeye salmon and 114 hatchery coho salmon O. kisutch. Differences in trap catch between years are due to fluctuations not only in smolt production, but also differences in trap efficiency and duration of trap operation associated with flow. The significant increase in catch in 2002 was due to a 3.1 fold increase in hatchery Chinook production and a more normal spring runoff. Trap operations began on March 10 and were terminated on June 7. The trap was out of operation for a total of four days due to mechanical failure or debris. Hatchery Chinook salmon catch at the Salmon River trap was 4.2 times greater and wild Chinook salmon catch was 2.4 times greater than in 2001. The hatchery steelhead trout collection in 2002 was 81% of the 2001 numbers. Wild steelhead trout collection in 2002 was 81% of the previous year's catch. Trap operations began on March 10 and were terminated on May 29 due to high flows. The trap was out of operation for four days due to high flow or debris. The increase in hatchery Chinook catch in 2002 was due to a 3.1 fold increase in hatchery production and differences in flow between years. Changes in hatchery and wild steelhead catch are probably due to differences in flow between years. Travel time (d) and migration rate (km/d) through Lower Granite Reservoir for PIT-tagged Chinook salmon and steelhead trout marked at the Snake River trap were affected by discharge. Statistical analysis of 2002 data detected a relation between migration rate and discharge for hatchery and wild Chinook salmon. For hatchery and wild Chinook salmon there was a 4.7-fold and a 3.7-fold increase in migration rate, respectively, between 50 and 100 kcfs. For steelhead trout tagged at the Snake River trap, statistical analysis detected a significant relation between migration rate and Lower Granite Reservoir inflow discharge. For hatchery and wild steelhead trout, there was a 1.8-fold and a 1.7-fold increase in migration rate, respectively, between 50 and 100 kcfs. Travel time and migration rate to Lower Granite Dam for fish marked at the Salmon River trap were calculated. Statistical analysis of the 2002 data detected a significant relation between migration rate and Lower Granite Reservoir inflow discharge for wild Chinook salmon and hatchery steelhead trout. The analysis was unable to detect a relation between migration rate and discharge for hatchery Chinook salmon. The lack of a detectable relation was probably a result of the migration rate data being spread over a very narrow range of discharge. Not enough data were available to perform the analysis for wild steelhead trout. Migration rate increased 4.3-fold for wild Chinook salmon and 2.2-fold for hatchery steelhead between 50 kcfs and 100 kcfs. Fish tagged with passive integrated transponder (PIT) tags at the Snake River trap were interrogated at four dams with PIT tag detection systems (Lower Granite, Little Goose, Lower Monumental, and McNary dams). Because of the addition of the fourth interrogation site (Lower Monumental) in 1993 and the installation of the Removable Spillway Weir at Lower Granite Dam in 2000, caution must be used in comparing cumulative interrogation data. Cumulative interrogations at the four dams for fish marked at the Snake River trap were 61% for hatchery Chinook, 68% for wild Chinook, 58% for hatchery steelhead, and 62% for wild steelhead. Cumulative interrogations at the four dams for fish marked at the Salmon River trap were 51% for hatchery Chinook, 59% for wild Chinook salmon, 45% for hatchery steelhead trout, and 54% for wild steelhead trout. Cumulative interrogations were significantly lower in 2002 than in previous years with similar flow.

13 HYDRO ENERGY↗