Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

High Power Density Thermal Energy Storage With Phase Change Material in Enhanced Compact Heat Exchangers

Abstract Performance of a novel ultracompact thermal energy storage (TES) heat exchanger, designed as a microchannel finned-tube exchanger is presented. With water as the heating–cooling fluid in the microchannels, a salt hydrate phase change material (PCM), lithium nitrate trihydrate (LiNO3 · 3H2O), was encased on the fin side. To establish the hypothesis that small-length-scale encasement (<3 mm) of PCM substantially enhances heat transfer to yield very high power-density energy storage, heat exchanger designs with 10 and 24 fins/inch were considered. They were subjected to thermal cycling, or repeated heating (melting) and cooling (freezing), with inlet fluid flow mimicking diurnal variation between 42 °C and 25 °C (representing typical arid-region conditions) over an accelerated time period. By employing salt self-seeding to obviate subcooling during cooling or recrystallization, the TES was found to exhibit stable long-term (100 heating–cooling cycles) operation with very high PCM-side heat transfer coefficients (∼100–500 W/m2 K) and storage power density (∼160–175 kW/m3). In fact, with optimization of heating–cooling fluid flowrate for given charging–discharging time period and exchanger size, power density >300 kW/m3 can be achieved. The results clearly establish that highly compact heat exchangers used as TES units can provide very high-performance alternatives to conventional ones.

Engineering↗

Quantification of regional early stage gas exchange changes using hyperpolarized {sup 129}Xe MRI in a rat model of radiation-induced lung injury

Purpose: To assess the feasibility of hyperpolarized (HP) {sup 129}Xe MRI for detection of early stage radiation-induced lung injury (RILI) in a rat model involving unilateral irradiation by assessing differences in gas exchange dynamics between irradiated and unirradiated lungs. Methods: The dynamics of gas exchange between alveolar air space and pulmonary tissue (PT), PT and red blood cells (RBCs) was measured using single-shot spiral iterative decomposition of water and fat with echo asymmetry and least-squares estimation images of the right and left lungs of two age-matched cohorts of Sprague Dawley rats. The first cohort (n = 5) received 18 Gy irradiation to the right lung using a {sup 60}Co source and the second cohort (n = 5) was not irradiated and served as the healthy control. Both groups were imaged two weeks following irradiation when radiation pneumonitis (RP) was expected to be present. The gas exchange data were fit to a theoretical gas exchange model to extract measurements of pulmonary tissue thickness (L{sub PT}) and relative blood volume (V{sub RBC}) from each of the right and left lungs of both cohorts. Following imaging, lung specimens were retrieved and percent tissue area (PTA) was assessed histologically to confirm RP and correlate with MRI measurements. Results: Statistically significant differences in L{sub PT} and V{sub RBC} were observed between the irradiated and non-irradiated cohorts. In particular, L{sub PT} of the right and left lungs was increased approximately 8.2% and 5.0% respectively in the irradiated cohort. Additionally, V{sub RBC} of the right and left lungs was decreased approximately 36.1% and 11.7% respectively for the irradiated cohort compared to the non-irradiated cohort. PTA measurements in both right and left lungs were increased in the irradiated group compared to the non-irradiated cohort for both the left (P < 0.05) and right lungs (P < 0.01) confirming the presence of RP. PTA measurements also correlated with the MRI measurements for both the non-irradiated (r = 0.79, P < 0.01) and irradiated groups (r = 0.91, P < 0.01). Conclusions: Regional RILI can be detected two weeks post-irradiation using HP {sup 129}Xe MRI and analysis of gas exchange curves. This approach correlates well with histology and can potentially be used clinically to assess radiation pneumonitis associated with early RILI to improve radiation therapy outcomes.

60 APPLIED LIFE SCIENCES↗

Momentum-exchange interactions in a Bragg atom interferometer suppress Doppler dephasing

Large ensembles of laser-cooled atoms interacting through infinite-range photon-mediated interactions are powerful platforms for quantum simulation and sensing. Here we realize momentum-exchange interactions in which pairs of atoms exchange their momentum states by collective emission and absorption of photons from a common cavity mode, a process equivalent to a spin-exchange or XX collective Heisenberg interaction. The momentum-exchange interaction leads to an observed all-to-all Ising-like interaction in a matter-wave interferometer. A many-body energy gap also emerges, effectively binding interferometer matter-wave packets together to suppress Doppler dephasing in analogy to Mössbauer spectroscopy. The tunable momentum-exchange interaction expands the capabilities of quantum interaction–enhanced matter-wave interferometry and may enable the realization of exotic behaviors, including simulations of superconductors and dynamical gauge fields.

Science & Technology - Other Topics↗

Exchange Spring in a Heterostructure with Pd{sub 0.96}Fe{sub 0.04} Low-Temperature Ferromagnet

The exchange bias of the magnetic hysteresis loop and the exchange-spring effect have been observed in thin-film heterostructures comprising layers of Pd{sub 0.96}Fe{sub 0.04} low-temperature ferromagnet, metallic cobalt, and cobalt monoxide (CoO) grown on single-crystalline sapphire by methods of magnetron sputtering and molecular beam epitaxy in an ultrahigh-vacuum system. It is established that the exchange anisotropy of Pd{sub 0.96}Fe{sub 0.04} layer in Pd{sub 0.96}Fe{sub 0.04}/CoO/Co/Al{sub 2}O{sub 3} thin-film heterostructure is absent and the exchange-spring effect in this system is not manifested. In the case of a Pd{sub 0.96}Fe{sub 0.04}/Co/CoO/Al{sub 2}O{sub 3} structure, it is shown that, according to the results of magnetometric measurements, the inversion of the order of antiferromagnetic and ferromagnetic layers leads to pinning of the magnetic moment of Pd{sub 0.96}Fe{sub 0.04} layer at the interface with cobalt and to realization of the exchange-spring effect. Additional evidence in favor of this interpretation was obtained using the micromagnetic modeling of magnetic hysteresis loops.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Leaf gas exchange, spectral reflectance and leaf composition, BIONTE, Brazil, 2022

Leaf traits measured at the top of the canopy on 10 species at the BIONTE experimental plot T1B4SB3, near Manaus, Brazil, in August and September, 2022. The aim of this study was to test the relationship between leaf water use efficiency and wood density. Ten tree species located in close proximity of each other (within 50 meters) were selected and classified by wood density (low or high). Sampling was carried out on top-of-canopy leaves accessed by an articulated boom lift. Survey gas exchange measurement were performed on attached leaves at various times during the day. Following gas exchange, the leaf was harvested, and measured for spectral reflectance, leaf water content, leaf mass per area and leaf carbon content and leaf nitrogen content. Additional leaves other than those used for gas exchange were also harvested from different branches on the same tree for spectral reflectance and leaf trait measurements. Data in this data package is presented in csv files, with metadata in csv and descriptive experimental protocols as pdf. Gas exchange data and metadata meets the requirements of the ESS-DIVE reporting format for leaf gas exchange data and metadata.

54 ENVIRONMENTAL SCIENCES↗

Leaf gas exchange, leaf water potential and spectral reflectance, BIONTE, Brazil, 2023

Leaf traits measured at the top of the canopy on 30 tree species in the BIONTE experimental forest, near Manaus, Brazil, at three time points during August to November, 2023. The aim of this study was to test the relationship between leaf water use efficiency and wood density. Leaf gas exchange was measured on top-of-canopy leaves accessed by an articulated boom lift. Response curves (A-Ci and A-Q), and dark adapted respiration were measured on cut branches. Survey gas exchange measurements were performed on attached leaves at various times during the day. Following gas exchange, leaves were harvested, and measured for leaf water potential and spectral reflectance. Data in this data package is presented in csv files, with metadata in csv and descriptive experimental protocols as pdf. Gas exchange data and metadata meets the requirements of the ESS-DIVE reporting format for leaf-level gas exchange data and metadata.

54 ENVIRONMENTAL SCIENCES↗

Experimental Findings on Actinide Recovery Utilizing Oxidation by Peroxydisulfate Followed by Ion Exchange

Our research seeks to determine if inorganic ion-exchange materials can be exploited to provide effective minor actinide (Am, Cm) separation from lanthanides. Previous work has established that a number of inorganic and UMOF ion-exchange materials exhibit varying affinities for actinides and lanthanides, which may be exploited for effective separations. During FY15, experimental work focused on investigating methods to oxidize americium in dilute nitric and perchloric acid with subsequent ion-exchange performance measurements of ion exchangers with the oxidized americium in dilute nitric acid. Ion-exchange materials tested included a variety of alkali titanates. Americium oxidation testing sought to determine the influence that other redox active components may have on the oxidation of Am III . Experimental findings indicated that Ce III , Np V , and Ru II are oxidized by peroxydisulfate, but there are no indications that the presence of Ce III , Np V , and Ru II affected the rate or extent of americium oxidation at the concentrations of peroxydisulfate being used.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low Cost Polymer heat Exchangers for Condensing Boilers

Work in this project sought to develop a suitable design for a low cost, corrosion resistant heat exchanger as part of a high efficiency condensing boiler. Based upon the design parameters and cost analysis several geometries and material options were explored. The project also quantified and demonstrated the durability of the selected polymer/filler composite under expected operating conditions. The core material idea included a polymer matrix with fillers for thermal conductivity improvement. While the work focused on conventional heating oil, this concept could also be applicable to natural gas, low sulfur heating oil, and biodiesel- although these are considered to be less challenging environments. An extruded polymer composite heat exchanger was designed, built, and tested during this project, demonstrating technical feasibility of this corrosion-resistant material approach. In such flue gas-to-air heat exchangers, the controlling resistance to heat transfer is in the gas-side convective layer and not in the tube material. For this reason, the lower thermal conductivity polymer composite heat exchanger can achieve overall heat transfer performance comparable to a metal heat exchanger. However, with the polymer composite, the surface temperature on the gas side will be higher, leading to a lower water vapor condensation rate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pu Anion Exchange Process Intensification

This research is focused on improving the efficiency of the anion exchange process for purifying plutonium. While initially focused on plutonium, the technology could also be applied to other ion-exchange processes. Work in FY17 focused on the improvement and optimization of porous foam columns that were initially developed in FY16. These foam columns were surface functionalized with poly(4-vinylpyridine) (PVP) to provide the Pu specific anion-exchange sites. Two different polymerization methods were explored for maximizing the surface functionalization with the PVP. The open-celled polymeric foams have large open pores and large surface areas available for sorption. The fluid passes through the large open pores of this material, allowing convection to be the dominant mechanism by which mass transport takes place. These materials generally have very low densities, open-celled structures with high cell interconnectivity, small cell sizes, uniform cell size distributions, and high structural integrity. These porous foam columns provide advantages over the typical porous resin beads by eliminating the slow diffusion through resin beads, making the anion-exchange sites easily accessible on the foam surfaces. The best performing samples exceeded the Pu capacity of the commercially available resin, and also offered the advantage of sharper elution profiles, resulting in a more concentrated product, with less loss of material to the dilute heads and tails cuts. An alternate approach to improving the efficiency of this process was also explored through the development of a microchannel array system for performing the anion exchange.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Cesium Ion Exchange Testing Using Crystalline Silicotitanate with Hanford Tank Waste 241-AP-107

The Low-Activity Waste Pretreatment System (LAWPS) provides for the early production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility for immobilization. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 (hereafter called AP-107) be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange) then vitrified. A small-scale test platform to demonstrate the solids filtration, Cs removal, and LAW vitrification was constructed and installed at the Pacific Northwest National Laboratory. Bench-scale ion exchange testing with approximately 9 L of AP-107 supernate was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Batch 2081000057). The ion exchange media was first tested with simulant and was previously described. This report describes the Cs ion exchange batch contact and column test results with the AP-107 tank waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data Driven Temperature Control of Heat Exchangers

The following poster presents a couple of approaches for temperature control at heat exchanger’s exit. One of the approaches is based on using n-step ahead neural network while the other approach utilizes a combination of control + learning module for temperature control. Designing robust controllers for typical heat exchangers is very challenging primarily because of complexities associated with the synthesis of dynamics of industrial heat exchangers. Even if a dynamics model is synthesized, the accuracy of it would be called into question as there can be lot of unmodeled system dynamics and random noise in input parameters. In many situations, the degree of uncertainty in the model of system being controlled limits the utility of optimal control design. Controller can be manually tuned on the field but it is very difficult to determine manual adjustments that result in overall improvement. These practical challenges call for learning based approaches for temperature control that would result in optimal heat exchanger performance. We utilize the existing mathematical model for air-water system synthesized by Underwood and Crawford for testing our algorithms. Underwood and Crawford developed a model of heating coil by fitting a second-order non-linear equations to measurements of air and water temperature and flow rates obtained from the actual coil. The uncertainties in the model include air and water inlet temperatures and air-flow rate. These uncertainties are modeled as random variables that are sampled from a uniform distribution. The control variable is the water flow rate which is controlled for regulating the air-outlet temperature. Neural networks are frequently used in various literatures for learning time-series. We propose a modified version of neural networks known as n-step ahead neural network that take the state variables and output at time t as input to successfully predict output at time t+n. The variable n is a hyper-parameter which can be optimized based on performance constraints. The n-step ahead neural network was then trained on training data generated from experimental model to high training accuracies. This trained model performed appreciably in its objective to regulate outlet temperature of a heat exchanger. The second approach uses a combination of control and learning module for temperature regulation. The control module used is a proportional controller while the learning module used is steady state neural network. The steady state neural network is used to learn the controller output as a function of random variables and temperature set-point. The proportional controller is then used to compensate for transient behavior of linearized system around various operating points. The algorithm works effectively for temperature regulation as neural network captures the non-linear input-output behavior of closed loop system leaving proportional controller to compensate for steady state errors of a linearized plant. The proposed algorithm’s performances were evaluated against the performance of a PI controller. Further, the robustness of the algorithms were also studied in great detail under small perturbations around tuned parameters of the proposed algorithms.

Sundar, Sreenath↗

Modified Isotherm Modeling to Predict Cs Exchange with Crystalline Silicotitanate in Tank Waste Simulants

The U.S. Department of Energy is working to expedite processing of Hanford tank waste supernate at the Hanford Waste Treatment and Immobilization Plant. To support this goal, Washington River Protection Solutions is designing a Tank Side Cesium Removal (TSCR) system for suspended solids and cesium (Cs/ 137 Cs) removal from Hanford tank waste supernate. The ion exchange media selected for Cs removal at TSCR is crystalline silicotitanate (CST) that is manufactured in a nearly spherical form by Honeywell UOP LLC (UOP; Des Plaines, IL) as product IONSIV® R9140-B (Na form). The Zheng Anthony Miller (ZAM) isotherm model (Zheng et al. 1997) is a multicomponent ion exchange model used to predict the exchange of Group I metals onto CST. The ZAM isotherm has historically been used to predict Cs distribution values from Hanford and Savannah River Site (SRS) tank waste simulants. Figure S.1 summarizes model predictions from the ZAM isotherm that indicate poor prediction of Cs distribution values for simple and complex simulants with the engineered form of CST, IONSIV® R9140-B, and IONSIV® R9120-B where the solid line indicates a perfect fit by the model. The dotted lines indicate ±20% error. Batch contact testing with Hanford tank waste complex and simple simulants was used in conjunction with SRS simulants to experimentally determine Cs distribution values using a modification to the original isotherm model. The experimentally determined maximum Cs capacity for IONSIV® R9140-B CST in both the simple and complex matrices was found to be 0.53±0.3 mmoles Cs/g of CST. This value is not drastically different from the maximum Cs capacity of 0.58 mmoles Cs/g TAM-5 reported by Zheng et al. (1997). However, it is important to note that TAM-5 (commercially IONSIV® IE-910) is a powder. Hamm et al. (2002) determined that a dilution factor was needed to account for the Zr(OH)2 binder in the engineered form of CST. Hamm et al. determined that a dilution factor of 0.68 was appropriate to account for binder contribution and correct overprediction of Cs exchange on the engineered form of CST in ZAM calculations. This reduced the total capacity from 0.58 mmol/g with TAM-5 to 0.39 mmol/g for the engineered form of CST (Hamm et al. 2002). Despite substituting the experimentally determined maximum Cs capacity of 0.55 mmoles Cs/g for the literature-reported capacity of 0.39 mmoles Cs/g, it was determined that additional modifications to the model’s equilibrium rate constants were necessary in refining the isotherm model. The modified model overpredicted K+ uptake by the CST when compared to digested CST results described by Campbell et al. (2019). The modified model was further revised to omit three of the five K+ exchange equilibrium reactions described by ZAM to reduce the additional K+ loading seen by the model. Figure S.2 summarizes the revised model isotherm predictions plotted against measured Kd values.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AP-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System (Rev.1)

The Tank Side Cesium Removal (TSCR) system, under development by Washington River Protection Solutions LLC (WRPS), will send initial low-activity Hanford waste tank supernate feeds to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B), was selected as the ion exchange media at TSCR. CST is a non-elutable inorganic material that has demonstrated robust chemical, physical, and radiation tolerance while maintaining functionality. However, exchange kinetics of Cs onto CST is slow, resulting in low utilization of the CST Cs load capacity before unacceptable Cs breakthrough. Two process flow designs have been tested, as follows. 1. Lead-lag column processing: The lead column was removed after the lag column effluent reached the waste acceptance criteria (WAC) limit, the lag column was moved into the lead position, and a new lag column was installed. This format used ~52% Cs load capacity on the lead column. 2. Lead-lag-polish column processing: The processing was stopped when the polish column effluent reached the WAC limit. This format resulted in 81% Cs load capacity on the lead column. Testing with diluted feed from Hanford tank AP-105 (AP-105DF) incorporated a nuanced change to the lead-lag-polish column system where the polish column was inserted when the lag column effluent reached WAC limit. A 10.9-L volume of AP-105DF (diluted to 5.6 M Na) was processed through the Direct Feed Test Platform system, established at Pacific Northwest National Laboratory to support small-scale waste qualification efforts. The columns consisted of 10-mL CST beds (CST Lot 2002009604, sieved to screen out >30-mesh particles) placed in 1.5-cm-inner-diameter columns. Feed was processed at 1.83 bed volumes (BV) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The <30-mesh CST sieve cut was expected to provide appropriate performance scaling to a full-height column. The installation of the polish column later in processing (after processing 523 BVs) did not appear to fundamentally change the utilization of the lead column for Cs exchange nor did it extend the total feed processing volume when compared to the previous test with AP-107 feed. Table ES.1 and Figure ES.1 summarize the measured AP-105DF Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Best-Practices and Computationally Inexpensive Radiative Exchange Models for Discrete Element Method Modeling of Aluminosilicate Particles in Concentrating Solar Power Environments

Chemically inert, aluminosilicate based particles have been investigated as both a thermal transport and sensible energy storage medium for concentrating solar power facilities. These particles will experience a wide range of operating temperatures (300-1000 K) and handling conditions (dense to dilute falling particle curtains, dense granular flows, or dense structures), requiring specially-designed and optimized infrastructures. The relative influence of collisional and frictional interactions between particles varies based on temperature-dependent particulate properties and greatly impacts the bulk, granular flow behavior. These underlying physics are captured using discrete element method modeling tools. However, this modeling method is computationally expensive as each particle position and interaction is tracked during the simulation. These modeling methods are further complicated by introducing temperature-dependent particle properties, high-temperature radiative exchange, and directional irradiation sources experienced by granular flows in concentrating solar power environments. In this study, coupled experimental and numerical slump testing of aluminosilicate particles was performed and computationally efficient radiative exchange models were evaluated to establish best-practices for discrete element method models for concentrating solar power environments. The three particle types investigated included Carbobead HSP 30 /60, Carbobead CP 30/60, and Granusil 4030. Existing modeling limitations and computationally-efficient multi-modal heat transfer models were evaluated using Aspherix®, a commercial discrete element method software. High-temperature (< 1073 K) slump testing of aluminosilicate particles was performed to investigate the deviation between experimentally-observed and numerically-predicted angles of repose introduced by computation-time reduction practices including the relaxation of the particle elastic modulus and coarse-graining. Coarse-graining is used to use a single modeled particle that is representative of a collection of smaller particles, decreasing the computational cost at the expense of geometric accuracy. Additionally, relaxation of the elastic modulus is used to reduce computational time at the expense of an increased, modeled particle overlap. Prior studies have determined that aluminosilicate particles retain a high elastic modulus at high temperatures (< 1073 K), requiring small simulation timesteps to ensure resolved contact forces resemble appropriate solid mechanics. A parametric study was performed to evaluate the influence of computation time improvements on the deviation between experimental and modeled angle of repose across high temperatures < 1073 K. Additionally, numerical case studies were performed on candidate particle systems at varying porosities and temperatures. These studies were performed to investigate the influence of computationally-efficient radiative-exchange modeling methods coupled to Aspherix® on modeled accuracy and computation time. The recently-developed distance-based approximation was evaluated in estimating radiative exchange between particles and participating surfaces located in close proximity. The distance based approximation was developed to use tabulated estimates of the radiative distribution factor between individual particles and surfaces in close proximity (< 40 particle radii). These methods were expanded to the aluminosilicate particles of interest, including the influence of particle size distributions. To capture radiative exchange between particles and surfaces not in close proximity (> 40 particle radii) and to capture the absorption of directional irradiation from concentrating solar resources, a volumetrically-averaged radiative distribution factor was calculated between the modeled granular flow and surfaces using Monte Carlo ray-tracing for participating media. Volume-averaged absorption and scattering coefficients were predicted using a volumetric discretization of the modeled domain with monodisperse approximations based on geometric optics and experimentally-determined scattering phase functions for aluminosilicate particles.

14 SOLAR ENERGY↗

Multi-physics Topology OPtimization and Additive Manufacturing for High-temperature Heat Exchangers

This research significantly advances the understanding of high-temperature heat exchanger design through an integrated approach that combines topology optimization (TO), triply periodic minimal surface (TPMS) structures, additive manufacturing (AM) and thermohydraulic testing. Each of these components contributes uniquely to a unified, high-performance design, fabrication and testing workflow. Topology optimization serves as the foundation of the design methodology by providing a systematic way to determine the most effective material layout for separating hot and cold fluids while maximizing thermal performance. The researchers introduced a novel three-material optimization framework using two density fields to represent hot fluid, cold fluid, and solid domains. This approach enables automated discovery of optimal shapes and flow paths that cannot be intuitively designed, especially under constraints imposed by manufacturing technologies. Furthermore, constraints such as minimal wall thickness and overhang angles were embedded into the optimization process, ensuring that resulting designs are not only thermally efficient but also manufacturable using modern additive techniques. In parallel, the study delves into the use of Gyroid-based TPMS geometries for constructing the core of the heat exchanger. TPMS structures are known for their high surface area, excellent fluid mixing capabilities, and minimal pressure drop characteristics. The researchers applied a data-driven modeling framework using Heteroscedastic Sparse Gaussian Process Regression (HSGPR) combined with genetic algorithms. This allowed for the rapid evaluation and optimization of key geometric parameters such as frequency, iso-value, and phase shift. The result was a set of Gyroid structures tailored for high heat transfer and low flow resistance, demonstrating clear improvements over conventional straight-channel designs. After the designing process, additive manufacturing played a critical role by turning these highly complex, optimized geometries into physical components. Utilizing Laser Powder Bed Fusion (LPBF) with Haynes 282, the study demonstrated the feasibility of fabricating these heat exchangers at high precision. Post-processing methods, including dilation-erosion operations, were applied to ensure local features adhered to self-supporting constraints. The fabricated structures were then subjected to thermohydraulic testing under conditions representative of supercritical CO 2 Brayton cycles, validating the predicted performance and confirming the viability of the full design-to-fabrication pipeline. Finally, thermohydraulic testing across the above studies served as a crucial experimental validation of advanced heat exchanger. Under consistent high-temperature and high-pressure conditions using supercritical CO 2 , the testing demonstrated that both TO and Gyroid-based TPMS designs significantly outperformed conventional straight-channel HXs. The TO design achieved a 115% increase in UA and NTU and a 27.6% boost in gravimetric power density, while the data-driven optimized Gyroid design delivered a 166% increase in UA and NTU and improved effectiveness from 68.7% to 86.1%. These results validate the simulation models, confirm the manufacturability of complex geometries under AM constraints, and provide key insights into design-performance trade-offs, thereby advancing the development of high-efficiency, compact heat exchangers for extreme environments.

36 MATERIALS SCIENCE↗

Riverbed Temperature and 4D ERT Monitoring Reveals Heterogenous Horizontal and Vertical Groundwater-Surface Water Exchange Flows Under Dynamic Stage Conditions

Groundwater surface water exchange plays a critical role in physical, biological, and geochemical function of coastal and riverine systems. Observing exchange flow behavior in heterogeneous systems is a primary challenge, particularly when flows are governed by dynamic river stage or tidal variations. In this paper we demonstrate a novel application of time-lapse 3D electrical resistivity tomography and temperature monitoring where an array of thermistors installed beneath a riverbed double as resistivity electrodes. We use the array to monitor stage driven exchange flows over a 6-day period in a dynamic, stage-driven high order stream. We present a method for addressing the otherwise confounding effects of the moving river-surface boundary on the raw resistivity data, thereby enabling successful tomographic imaging. Temperature time-series at each thermistor location and time-lapse 3D images of changes in bulk electrical conductivity together provide a detailed description of exchange dynamics over a 10-meter by 45-meter section of the riverbed, to a depth of approximately 5 m. Results reveal highly variable flux behavior throughout the monitoring domain including both horizontal and vertical exchange flows.

54 ENVIRONMENTAL SCIENCES↗

Quantifying Lithium Ion Exchange in Solid Electrolyte Interphase (SEI) on Graphite Anode Surfaces

Solid Electrolyte Interphase (SEI) has been identified as the most important and least understood component in lithium-ion batteries. Despite extensive studies in the past two decades, a few mysteries remain: what is the chemical form of and degree of mobility of Li + in the interphase? What fraction of Li + is permanently immobilized in the SEI, while the rest are still able to participate in the cell reactions via the ion-exchange process with Li + in the electrolyte? This study attempted to answer, in part, these questions by using 6 Li and 7 Li-isotopes to label SEIs and electrolytes, and then quantifying the distribution of permanently immobilized and ion-exchangeable Li + with solid-state NMR and ToF-SIMS. The results showed that the majority of Li + were exchanged after one SEI formation cycle, and a complete exchange after 25 cycles. Ion exchange by diffusion based on concentration gradient in the absence of applied potential also occurred simultaneously. This knowledge will provide a foundation for not only understanding but also designing better SEIs for future battery chemistries.

25 ENERGY STORAGE↗

Spatial and temporal variation in river corridor exchange across a 5th-order mountain stream network

Although most field and modeling studies of river corridor exchange have been conducted at scales ranging from tens to hundreds of meters, results of these studies are used to predict their ecological and hydrological influences at the scale of river networks. Further complicating prediction, exchanges are expected to vary with hydrologic forcing and the local geomorphic setting. While we desire predictive power, we lack a complete spatiotemporal relationship relating discharge to the variation in geologic setting and hydrologic forcing that is expected across a river basin. Indeed, the conceptual model of Wondzell (2011) predicts systematic variation in river corridor exchange as a function of (1) variation in baseflow over time at a fixed location, (2) variation in discharge with location in the river network, and (3) local geomorphic setting. To test this conceptual model we conducted more than 60 solute tracer studies including a synoptic campaign in the 5th-order river network of the H. J. Andrews Experimental Forest (Oregon, USA) and replicate-in-time experiments in four watersheds. We interpret the data using a series of metrics describing river corridor exchange and solute transport, testing for consistent direction and magnitude of relationships relating these metrics to discharge and local geomorphic setting. We confirmed systematic decrease in river corridor exchange space through the river networks, from headwaters to the larger main stem. However, we did not find systematic variation with changes in discharge through time or with local geomorphic setting. While interpretation of our results is complicated by problems with the analytical methods, the results are sufficiently robust for us to conclude that space-for-time and time-for-space substitutions are not appropriate in our study system. Finally, we suggest two strategies that will improve the interpretability of tracer test results and help the hyporheic community develop robust datasets that will enable comparisons across multiple sites and/or discharge conditions.

54 ENVIRONMENTAL SCIENCES↗