Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Engineering, Energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Non-equilibrium low-temperature plasma-assisted combustion of iso-octane: Perturbing pyrolysis and oxidation kinetics

Here, in this study, a plasma-coupled flow reactor facility is used to examine the effects of non-equilibrium low-temperature plasmas on perturbing the pyrolysis and oxidation kinetics of iso-octane. Experiments were performed in highly dilute reactive mixtures of nitrogen, at near isothermal conditions for temperatures ranging from 523 K to 1203 K. Experiments cumulatively demonstrated enhanced chemical reactivity with the plasma for temperatures below 900 K, and a lowering of the hot-ignition temperature. Detailed kinetic insight was derived from a 0D plasma-coupled kinetic model, utilizing a constructed mechanism that combined both plasma-specific chemistry and the neutral combustion chemistry. For pyrolysis conditions, the model displayed relatively good agreement with fuel consumption and the formation of most intermediates compared to the experimental data, demonstrating the model is able to accurately predict primary radical formation from the plasma directly interacting with the fuel. Enhanced reactivity was attributed to collisional quenching of excited-states of N 2 with fuel, which led to efficient fuel fragmentation and enhancement of the H-radical flux. For oxidation conditions, the model displayed satisfactory agreement with the experiments. Model predictions were able to accurately predict fuel consumption and most intermediate speciation data for T > 800 K, but most discrepancies were towards T < 800 K in particular with oxygenated intermediates. In the presence of oxygen, plasma effects were predominantly spent on efficient enhancement of O- and H-radical fluxes, leading to further fuel fragmentation and initiation of both the OH- and HO 2 -radical pools. Subsequent reactivity of iso-octane was then dictated by the response of the temperature-dependent neutral chemistry. At low-temperatures (T = 643 K), enhanced fuel radicals and O 2 -additon chemistry lead to the formation of oxygenated species, while at intermediate temperatures (T = 843 K) net decrease in OH-radical reactivity led to an increase in hydrocarbon speciation. Near the self-ignition threshold (T = 1163 K), radicals generated by high-temperature branching reactions dominate the oxidation process and effectively ignition. This study ultimately demonstrated that the enhancement of radicals afforded by the plasma causes a deviation in known understanding of iso-octane kinetics in some regards and warrants future studies to reconcile these discrepancies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Theoretical estimates of flammability bounds for thin condensed fuel diffusion flames in microgravity using detailed models of chemistry and radiation

Recently, U-shape flammability maps have been constructed showing minimal oxygen vs. flame strain for opposed flame spread in micro-gravity by Olson and Ferkul. The U-shape defines the limiting flammability bounds from radiative extinction and flame blow-off. Here, the minimum of the U corresponds to the minimum possible oxidizer concentration where burning can occur, and is an important quantity of interest for fire safety. While high strain extinction bounds have been well analyzed, low strain radiative extinction has not. To estimate low strain extinction, in this study an analytical theory is developed based on thin flame theory coupled with a heat and mass transfer model for solid fuels. A reaction progress variable based on the Damköhler number is adapted in the theory to account for incomplete combustion at high strain rates and enable the capturing of the full flammability map. The analytical model is compared to a one dimensional numerical model w/ detailed chemical kinetics and coupled radiation heat transfer in planar and spherical geometries. The flammability maps are then qualitatively compared to experimental extinguishment data compiled by Olson and Ferkul for cylindrical rods of PMMA showing similar trends. The results show the newly developed analytics capture the radiative extinction bound compared to the numerical model and qualitatively agrees with microgravity data.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Plasma-based global pathway analysis to understand the chemical kinetics of plasma-assisted combustion and fuel reforming

The Global Pathway Analysis (GPA) algorithm helps analyze the chemical kinetics of complex combustion systems by identifying important global reaction pathways connecting a source species to a sink species through various important intermediate species (i.e., hub species). Here, the present work aims to extend GPA algorithm to plasma-assisted combustion and fuel reforming systems to identify the dominant global pathways in such systems at various conditions. In addition, the present study extends the ability of GPA algorithm to identify reaction cycles involving the excitation of high-concentration species (e.g., O 2 , N 2 , and fuel) to their vibrational and electronic states and the subsequent de excitation to their ground state, based on their significance on the reactivity of plasma-assisted systems in terms of gas heating and radical production. Provisions are made in the GPA algorithm to evaluate the reactivity of identified re action pathways and cycles based on the element-flux transfer (i.e., dominance), heat release, and radical production rate. The newly developed Plasma-based Global Pathway Analysis (PGPA) algorithm is then used to analyze the plasma assisted combustion of ammonia and reforming of methane. The PGPA analyses elucidated the significance of vibrational-translational cycles on the reactivity of NH 3 /air mixtures. Further, analyses on the production of NO ascribed the early reforming of NH 3 to N 2 and H 2 in impeding the production of NO during plasma-assisted NH 3 ignition. Lastly, the enhanced reforming of CH 4 /N 2 mixtures using plasma has been attributed to electron impact dissociation of CH 4 when compared to thermal reforming. In contrast, conventional path-Flux analysis (PFA) was found to require significant manual effort and pre-analysis intuitions from expert knowledge, making it arduous to provide valuable in sights into plasma chemistry. The user-friendly and automated nature of PGPA thus provides a valuable tool for assessing the kinetics of plasma-assisted systems helpful in analyzing and, further, a foundation in reducing plasma-assisted chemistry, without the needs of expert knowledge.

33 ADVANCED PROPULSION SYSTEMS↗

A simple-structured benzo[1,2-b:4,5-b’]dithiophene-based molecule as a third component enables organic solar cells with over 18.2% efficiency

In this study, research has shown that ternary strategy is an effective tool for improving the performance of organic solar cells (OSCs) and simple-structured small molecules with low-cost and wide bandgap which broadens the scope of the choice in third components recently attracted the attention of researchers. Herein, a small molecule with benzo[1,2-b:4,5-b’]dithiophene (BDT) core named BR-C12 which mixed well with PM6 has been designed and synthesized. Incorporating BR-C12 as third component into PM6:Y6, BR-C12 exhibits a complementary absorption with PM6 and Y6, promoted exciton dissociation and charge collection, reduced bimolecular recombination, resulting in more ordered molecular packing. The PM6:Y6:BR-C12 (1:1.2:0.1, weight ratio) OSC shows an improved power conversion efficiency (PCE) of 17.02% in comparison to host binary devises (16.42%). In addition, by employing BR-C12 as third component into PM6:L8-BO, the ternary device based on PM6:L8-BO:BR-C12 also achieves significant enhancement in device photovoltaic performance with a PCE of 18.26%. In addition, BR-C12-added ternary devices exhibit improved stability than binary ones. This work presents a method for constructing high-performance ternary OSCs and enriches the abundance of materials for the third components.

14 SOLAR ENERGY↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A zone-level occupancy counting system for commercial office spaces using low-resolution time-of-flight sensors

Understanding the locations of occupants in a commercial built environment is critical for realizing energy savings by delivering lighting, heating, and cooling only where it is needed. In this paper, we present an indoor occupancy counting system using a sparse array of inexpensive, low-resolution, and privacy-preserving time-of-flight sensors. We develop and validate an algorithm for zonal occupancy counting that can deal with multiple people walking underneath the sensors in arbitrary directions, and evaluate the system both in realistic simulations of office spaces and in a real-world installation. Finally, we found that our system has an error rate of around 0.4%, resulting in highly accurate person localization and zone counting using only a few sensors per space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of common faults on an air conditioner with a microtube condenser and analysis of fault characteristic features

Split system air conditioners are widely used to cool residential buildings, because of their low cost and simplicity. However, their efficiency is impacted by installation faults, which include: improper refrigerant charge (undercharge or overcharge), improper evaporator airflow, liquid line restrictions (LL), and the presence of non-condensable gas (NC) in the refrigerant. No known previously published research has studied the effect of these four faults on a system equipped with a microtube condenser, which has smaller tube size than a traditional condenser and therefore holds less refrigerant charge, but has a different configuration than a microchannel. Furthermore, very few have studied the impacts of LL and NC. Herein this paper describes laboratory fault tests of a microtube-equipped system, compares the fault impacts with those of a traditional system, and considers the characteristic fault features. The tested system uses R-410A refrigerant and has a scroll compressor, a fixed orifice expansion device, and two fin-tube heat exchangers. The tests were carried out under steady operation with a range of fault intensities and operating conditions. The microtube system’s performance degradation from faults is similar to systems with traditional heat exchangers, despite the reduced capacity to hold refrigerant charge.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and testing of a performance evaluation methodology to assess the reliability of occupancy sensor systems in residential buildings

With the emergence of advanced occupancy sensor technologies to better detect occupancy in buildings, a universal methodology and metrics are required to evaluate and report sensor systems’ reliability and compare the performance across multiple sensor systems. Herein this research presents a methodology to assess the reliability of occupancy sensor systems in residential buildings in a controlled laboratory environment, including both “typical” and “failure” testing scenarios. The developed methodology was then implemented to evaluate a novel occupancy detection sensor system’s reliability. “Typical” testing evaluates the overall accuracy of the sensor system, which suggest how reliable the occupancy sensor system is over time. Results show that on average, the precision and recall are 0.75 and 0.70, indicating similar numbers of false positives and false negatives across the dataset. The overall accuracy of the tested sensor system was 62.4% to 76.4%. Failure testing results indicate whether there are influential variables impacting the sensor performance. For the tested sensor system, the number of occupants, presence of large objects, presence of interior light sources, and number of doors are not influential, while lighting level, location of occupants, additional door in the entry/exit area, and having the TV on are variables determined to impact the sensor system performance.

47 OTHER INSTRUMENTATION↗

Incorporating two-dimensional conduction modeling techniques into an energy simulation program: The EnergyPlus radiant system example

Due to the inherent complexity of multi-dimensional solutions for transient conduction in a multilayered building element, most heat balance-based algorithms assume that conduction occurs only in one dimension—through the building element between the inside and outside environments. Usually, since the length and width of the elements are much greater than the thickness of the element, this is a valid assumption. However, there are some cases such as hydronic radiant slabs where this assumption may not lead to an accurate estimate of the energy consumption of the system. In a hydronic radiant slab, water tubes are embedded in a slab, and hot or chilled water is circulated to meet any heating or cooling loads. The energy consumption of such a system will depend highly on the temperature of the water being sent to the slab (i.e., produced by the boiler or chiller). The temperature of the water that must be sent to the slab will depend on the spacing of the tubes, the multilayer construction of the building element, and the boundary conditions to which the construction is exposed. Thus, to accurately predict the energy consumption of such a system, a transient two-dimensional heat conduction model must be integrated with a heat balance-based simulation. This paper demonstrates the potential loss of accuracy associated with the one-dimensional radiant system models by providing a comparison of one- and two-dimensional solutions using EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗