Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRON SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

NuSTAR Observations of Abell 2163: Constraints on Non-thermal Emission

Since the first non-thermal reports of inverse Compton (IC) emission from the intracluster medium (ICM) of galaxy clusters at hard X-ray energies, we have yet to unambiguously confirm IC emission in observations with newer facilities. RXTE detected IC emission in one of the hottest known clusters, Abell 2163 (A2163), a massive merging cluster with a giant radio halo—the presumed source of relativistic electrons IC scattering CMB photons to X-ray energies. The cluster's redshift (z ~ 0.2) allows its thermal and non-thermal radio emission to fit the field of view of the Nuclear Spectroscopic Telescope Array (NuSTAR), permitting a deep observation capable of confirming or ruling out the RXTE report. The IC flux provides constraints on the average magnetic field strength in a cluster. To determine the global diffuse IC emission in A2163, we fit its global NuSTAR spectrum with four models: single- (1T) and two-temperature (2T), 1T+power-law component (T+IC), and multi-temperature+power law (9T+IC). Each represents different characterizations of the thermal ICM emission, with power-law components added to represent IC emission. We find that the 3–30 keV spectrum can be described by purely thermal emission, with a global average temperature of kT = (11.8 ± 0.2) keV. The IC flux is constrained to <4.0 × 10 –12 erg s –1 cm –2 using the 1T+IC model and <1.6 × 10 –12 erg s –1 cm –2 with the more physical 9T+IC model, both to 90% confidence levels. Here, combining these limits with 1.4 GHz diffuse radio data from the VLA, we find the average magnetic field strength to be >0.22 μG and >0.35 μG, respectively, providing the strongest constraints on these values in A2163 to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Battery inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 30 kW off-the-shelf grid following battery inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV inverter experimental data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Due to the limitations of the DC supply used, inverter is tested under 75%, 50%, 25% load conditions (This dataset does not contain 100% load condition). In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Split phase inverter data

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 8.35 kW off-the-shelf grid following split phase PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. Inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.9 to 1.1 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59 Hz to 61 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PV Inverter Experimental Dataset Version 2 with 100 Percent Power

The increase in power electronic based generation sources require accurate modeling of inverters. Accurate modeling requires experimental data over wider operation range. We used 20 kW off-the-shelf grid following PV inverter in the experiments. We used controllable AC supply and controllable DC supply to emulate AC and DC side characteristics. The experiments were performed at NREL's Energy Systems Integration Facility. The PV inverter is tested under 100%, 75%, 50%, 25% load conditions. In the first dataset, for each operating condition, controllable AC source voltage is varied from 0.88 to 1.09 per unit (p.u) with a step value of 0.025 p.u while keeping the frequency at 60 Hz. In the second dataset, under similar load conditions (100%, 75%, 50%, 25% ), the frequency of the controllable AC source voltage was varied from 59.4 Hz to 60.45 Hz with a step value of 0.2 Hz. Voltage and frequency range is chosen based on inverter protection. Voltages and currents on DC and AC side are included in the dataset.

14 SOLAR ENERGY↗

Monitor senses amount of contamination deposited on surfaces

Monitoring device detects and indicates directly the amount of contamination deposited on a surface. It uses an optical system in conjunction with a reliable collimated light source and associated electronics. Change in its output signal is proportional to change in the optical absorption characteristics of the sample plate surface.

Sheehy, R. N.↗

High energy solar flare X-rays

Very high energy X-rays-and by that I means X-rays with energies in excess of 100 kilovolts or so-are observed from the sun only during very large solar flares, and even then only for a very few minutes. Unlike the lower energy X-ray measurements you heard about a little bit earlier, which are essentially measures of the thermal nature of the emitting region, the very high energy X-rays are a direct reflection of the high energy electrons in the source region.

Stephen S. Holt↗

Thermospheric temperature measurement technique.

A method for measurement of temperature in the earth's lower thermosphere from a high-velocity probes is described. An undisturbed atmospheric sample is admitted to the instrument by means of a free molecular flow inlet system of skimmers which avoids surface collisions of the molecules prior to detection. Measurement of the time-of-flight distribution of an initially well-localized group of nitrogen metastable molecular states produced in an open, crossed electron-molecular beam source, yields information on the atmospheric temperature. It is shown that for high vehicle velocities, the time-of-flight distribution of the metastable flux is a sensitive indicator of atmospheric temperature. The temperature measurement precision should be greater than 94% at the 99% confidence level over the range of altitudes from 120-170 km. These precision and altitude range estimates are based on the statistical consideration of the counting rates achieved with a multichannel analyzer using realistic values for system parameters.

Hueser, J. E.↗

Optical study of charge exchange collisions between He+ and CO2.

Helium ions were produced in an electron bombardment ion source and directed into a gas cell containing carbon dioxide. A Wien filter placed between the ion source and the gas cell insured that only singly charged helium ions reached the cell. The spectrum obtained for the bombardment of carbon dioxide with the helium ions at 1200 eV is shown in a graph. Prominent features of the lower spectrum are two atomic lines at 3889 and 4471 A.

Coplan, M. A.↗

Characterization of Metals Melting Discs: Skylab Experiment M551

Information developed to characterize flight and ground based samples from the metals melting experiment is detailed in this report. Included are the characteristics determined by nondestructive examination, visual observation, metallographic examination and posttest measurements. Comparisons of the flight and ground based discs showed that an electron beam heat source can be used successfully in zero gravity for cutting, welding, or melting. Few differences were observed that could be attributed to the absence of gravity in these operations.

Monroe, R. E.↗

Modulation of the Jovian decametric radio emission by IO

It is argued that the sweeping of trapped energetic MeV protons by Io can result in induced emissions. The instability is caused by the density gradient occurring at the edge of the cavity. It is shown that the azimuthal Larmor drift of the energetic protons which is transverse to both the local magnetic field and the density gradient can excite extraordinary waves with frequencies slightly above the local electron cyclotron frequency. It is found that the emission coefficient is proportional to the square root of (n sub p/n sub t), where n sub p and n sub t denote the density of the energetic protons and the density of the thermal electrons, respectively. The theory also predicts a lower frequency cutoff. This cutoff frequency depends upon the density of thermal electrons in the source region.

Wu, C. S.↗

Characterization of metals melting discs Skylab experiment M551

Characterizations of flight and ground based samples from the metals melting experiment are detailed. The characteristics were determined by nondestructive investigation, visual observation, metallographic examination, and post-test measurements. Comparisons of the flight and ground based discs showed that an electron beam heat source can be used in zero gravity for cutting, welding, or melting.

Monroe, R. E.↗

Line absorption studies of the interstellar gas near 1 million GHz

The Copernicus satellite now opens up the ultraviolet region for inspection, and the number of resonance lines which may be studied has increased from 6, seen in the visible, to more than 30. The distribution and properties of an important constituent of the interstellar gas, molecular hydrogen, can be studied in detail using this instrument. A more comprehensive picture may now be developed for element depletion factors, electron densities, and sources of ionization (UV photons, low energy cosmic and X-rays).

Jenkins, E. B.↗

Coatings for directional eutectics

Significant advances have been made in the development of an environmentally stable coating for a very high strength, directionally solidified eutectic alloy designated NiTaC-13. Three duplex (two-layer) coatings survived 3,000 hours on a cyclic oxidation test (1,100 C to 90 C). These coatings were fabricated by first depositing a layer of NiCrAl(Y) by vacuum evaporation from an electron beam heated source, followed by depositing an aluminizing overlayer. The alloy after exposure with these coatings was denuded of carbide fibers at the substrate/coating interface. It was demonstrated that TaC fiber denudation can be greatly retarded by applying a carbon-bearing coating. The coating was applied by thermal spraying followed by aluminization. Specimens coated with NiCrAlCY+Al survived over 2,000 hours in the cyclic oxidation test with essentially no TaC denudation. Coating ductility was studied for coated and heat-treated bars, and stress rupture life at 871 C and 1,100 C was determined for coated and cycled bars.

Rairden, J. R.↗

Ion beam sputter modification of the surface morphology of biological implants

The surface chemistry and texture of materials used for biological implants may significantly influence their performance and biocompatibility. Recent interest in the microscopic control of implant surface texture has led to the evaluation of ion beam sputtering as a potentially useful surface roughening technique. Ion sources, similar to electron bombardment ion thrusters designed for propulsive applications, are used to roughen the surfaces of various biocompatible alloys or polymer materials. These materials are typically used for dental implants, orthopedic prostheses, vascular prostheses, and artificial heart components. Masking techniques and resulting surface textures are described along with progress concerning evaluation of the biological response to the ion beam sputtered surfaces.

Weigand, A. J.↗

Optical properties of ion beam textured metals

Copper, silicon, aluminum, titanium and 316 stainless steel were textured by 1000 eV xenon ions from an 8-cm diameter electron bombardment ion source. Copper, silicon, and aluminum developed a cone structure with an average peak-to-peak distance ranging from 1 micron for silicon to 6 microns for aluminum. Titanium and 316 stainless steel developed a serpentine ridge structure. The average peak-to-peak distance for both of these materials was 0.5 micron. Total reflectance for air mass 0 and 2, solar absorptance, and total emittance, normalized for a 425 K black body were calculated from the reflectance measurements. All materials had solar absorptances between 0.93 (stainless steel) and 0.97 (silicon and aluminum). Total emittance values of 0.75, 0.80, and 0.85 for Si, Al, and Cu, respectively, resulted in a solar absorptance/total emittance ratio of approximately 1.2. Titanium and 316 stainless steel had values of 2.6 and 2.9, respectively, for this ratio.

Hudson, W. R.↗