Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Track Structure and the Biological Effectiveness of Accelerated Particles for the Induction of Chromosome Damage

Track structure models predict that at a fixed value of LET, particles with lower charge number, Z will have a higher biological effectiveness compared to particles with a higher Z. In this report we investigated how track structure effects induction of chromosomal aberration in human cells. Human lymphocytes were irradiated in vitro with various energies of accelerated iron, silicon, neon, or titanium ions and chromosome damage was assessed in using three color FISH chromosome painting in chemically induced PCC samples collected a first cell division post irradiation. The LET values for these ions ranged from 30 to195 keV/micron. Of the particles studied, Neon ions have the highest biological effectiveness for induction of total chromosome damage, which is consistent with track structure model predictions. For complex-type exchanges 64 MeV/ u Neon and 450 MeV/u Iron were equally effective and induced the most complex damage. In addition we present data on chromosomes exchanges induced by six different energies of protons (5 MeV/u to 2.5 GeV/u). The linear dose response term was similar for all energies of protons suggesting that the effect of the higher LET at low proton energies is balanced by the production of nuclear secondaries from the high energy protons.

George, K.↗

The effects of deuterium on static posture control

A significant operational problem impacting upon the Space Shuttle program involves the astronaut's ability to safely egress from the Orbiter during an emergency situation. Following space flight, astronauts display significant movement problems. One variable which may contribute to increased movement ataxia is deuterium (D2O). Deuterium is present in low levels within the Orbiter's water supply but may accumulate to significant physiological levels during lengthy missions. Deuterium was linked to a number of negative physiological responses, including motion sickness, decreased metabolism, and slowing of neural conduction velocity. The effects of D2O on static postural control in response to a range of dosage levels were investigated. Nine sugjects were divided into three groups of three subjects each. The groups were divided into a low, medium, and a high D2O dosage group. The subjects static posture was assessed with the use of the EquiTest systems, a commercially available postural control evaluation system featuring movable force plates and a visual surround that can be servoed to the subject's sway. In addition to the force plate information, data about the degree of subject sway about the hips and shoulders was obtained. Additionally, surface electromyographic (EMG) data from the selected lower limb muscles were collected along with saliva samples used to determine the amount of deuterium enrichment following D2O ingestion. Two baseline testing sessions were performed using the EquiTest testing protocol prior to ingestion of the D2O. Thirty minutes after dosing, subjects again performed the tests. Two more post-dosing tests were run with an interest interval of one hour. Preliminary data anlaysis indicates that only subjects in the igh dose group displayed any significant static postural problems. Future analyses of the sway and EMG is expected to reveal significant variations in the subject's postural control strategy following D2O dosing. While functionally significant static postural problems were not commonly observed, subjects in both the medium and high dosage groups displayed significant, and in some cases, severe voluntary movement problems.

Layne, Charles S.↗

The Biological Effectiveness of Accelerated Particles for the Induction of Chromosome Damage: Track Structure Effects and Cytogenetic Signatures of High-LET Exposure

Track structure models predict that at a fixed value of LET, particles with lower charge number, Z will have a higher biological effectiveness compared to particles with a higher Z. In this report we investigated how track structure effects induction of chromosomal aberration in human cells. Human lymphocytes were irradiated in vitro with various energies of accelerated iron, silicon, neon, or titanium ions and chromosome damage was assessed in using three color FISH chromosome painting in chemically induced PCC samples collected a first cell division post irradiation. The LET values for these ions ranged from 30 to 195 keV/micrometers. Of the particles studied, Neon ions have the highest biological effectiveness for induction of total chromosome damage, which is consistent with track structure model predictions. For complex-type exchanges 64 MeV/ u Neon and 450 MeV/u Iron were equally effective and induced the most complex damage. In addition we present data on chromosomes exchanges induced by six different energies of protons (5 MeV/u to 2.5 GeV/u). The linear dose response term was similar for all energies of protons suggesting that the effect of the higher LET at low proton energies is balanced by the production of nuclear secondaries from the high energy protons. All energies of protons have a much higher percentage of complex-type chromosome exchanges than gamma rays, signifying a cytogenetic signature for proton exposures.

George, K.↗

Improvement of Risk Assessment from Space Radiation Exposure for Future Space Exploration Missions

Protecting astronauts from space radiation exposure is an important challenge for mission design and operations for future exploration-class and long-duration missions. Crew members are exposed to sporadic solar particle events (SPEs) as well as to the continuous galactic cosmic radiation (GCR). If sufficient protection is not provided the radiation risk to crew members from SPEs could be significant. To improve exposure risk estimates and radiation protection from SPEs, detailed variations of radiation shielding properties are required. A model using a modern CAD tool ProE (TM), which is the leading engineering design platform at NASA, has been developed for this purpose. For the calculation of radiation exposure at a specific site, the cosine distribution was implemented to replicate the omnidirectional characteristic of the 4 pi particle flux on a surface. Previously, estimates of doses to the blood forming organs (BFO) from SPEs have been made using an average body-shielding distribution for the bone marrow based on the computerized anatomical man model (CAM). The development of an 82-point body-shielding distribution at BFOs made it possible to estimate the mean and variance of SPE doses in the major active marrow regions. Using the detailed distribution of bone marrow sites and implementation of cosine distribution of particle flux is shown to provide improved estimates of acute and cancer risks from SPEs.

Kim, Myung-Hee Y.↗

ExpoKids: An R-based tool for characterizing aggregate chemical exposure during childhood

Background: Aggregate exposure, the combined exposures to a single chemical from all pathways, is a critical children’s health issue. Objective: The primary objective is to develop a tool to illustrate potential differences in aggregate exposure at various childhood lifestages and the adult lifestage. Methods: We developed ExpoKids (an R-based tool) using oral exposure estimates across lifestages generated by US EPA’s Exposure Factors Interactive Resource for Scenarios Tool (ExpoFIRST). Results: ExpoKids is applied to illustrate aggregate oral exposure, for ten media, as average daily doses (ADD) and lifetime average daily doses (LADD) in five graphs organized across seven postnatal childhood lifestages and the adult lifestage. This data visualization tool conveys ExpoFIRST findings, from available exposure data, to highlight the relative contributions of media and lifestages to chemical exposure. To evaluate the effectiveness of ExpoKids, three chemical case examples (di[2-ethylhexyl] phthalate [DEHP], manganese, and endosulfan) were explored. Data available from the published literature and databases for each case example were used to explore research questions regarding media and lifestage contributions to aggregate exposure. Significance: These illustrative case examples demonstrate ExpoKids’ versatile application to explore a diverse set of children’s health risk assessment and management questions by visually depicting specific media and lifestage contributions to aggregate exposure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Predicting oncology drug-induced cardiotoxicity with donor-specific iPSC-CMs—a proof-of-concept study with doxorubicin

Abstract Many oncology drugs have been found to induce cardiotoxicity in a subset of patients, which significantly limits their clinical use and impedes the benefit of lifesaving anticancer treatments. Human induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) carry donor-specific genetic information and have been proposed for exploring the interindividual difference in oncology drug-induced cardiotoxicity. Herein, we evaluated the inter- and intraindividual variability of iPSC-CM-related assays and presented a proof of concept to prospectively predict doxorubicin (DOX)-induced cardiotoxicity (DIC) using donor-specific iPSC-CMs. Our findings demonstrated that donor-specific iPSC-CMs exhibited greater line-to-line variability than the intraindividual variability in impedance cytotoxicity and transcriptome assays. The variable and dose-dependent cytotoxic responses of iPSC-CMs resembled those observed in clinical practice and largely replicated the reported mechanisms. By categorizing iPSC-CMs into resistant and sensitive cell lines based on their time- and concentration-related phenotypic responses to DOX, we found that the sensitivity of donor-specific iPSC-CMs to DOX may predict in vivo DIC risk. Furthermore, we identified a differentially expressed gene, DND microRNA-mediated repression inhibitor 1 (DND1), between the DOX-resistant and DOX-sensitive iPSC-CMs. Our results support the utilization of donor-specific iPSC-CMs in assessing interindividual differences in DIC. Further studies will encompass a large panel of donor-specific iPSC-CMs to identify potential novel molecular and genetic biomarkers for predicting DOX and other oncology drug-induced cardiotoxicity.

Toxicology↗

Simultaneous Exposure of Cultured Human Lymphoblastic Cells to Simulated Microgravity and Radiation Increases Chromosome Aberrations

During space travel, humans are continuously exposed to two major environmental stresses, microgravity (μG) and space radiation. One of the fundamental questions is whether the two stressors are interactive. For over half a century, many studies were carried out in space, as well as using devices that simulated μG on the ground to investigate gravity effects on cells and organisms, and we have gained insights into how living organisms respond to μG. However, our knowledge on how to assess and manage human health risks in long-term mission to the Moon or Mars is drastically limited. For example, little information is available on how cells respond to simultaneous exposure to space radiation and μG. In this study, we analyzed the frequencies of chromosome aberrations (CA) in cultured human lymphoblastic TK6 cells exposed to X-ray or carbon ion under the simulated μG conditions. A higher frequency of both simple and complex types of CA were observed in cells exposed to radiation and μG simultaneously compared to CA frequency in cells exposed to radiation only. Our study shows that the dose response data on space radiation obtained at the 1G condition could lead to the underestimation of astronauts’ potential risk for health deterioration, including cancer. This study also emphasizes the importance of obtaining data on the molecular and cellular responses to irradiation under μG conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Radiation Exposure Analyses Supporting the Development of Solar Particle Event Shielding Technologies

NASA has plans for long duration missions beyond low Earth orbit (LEO). Outside of LEO, large solar particle events (SPEs), which occur sporadically, can deliver a very large dose in a short amount of time. The relatively low proton energies make SPE shielding practical, and the possibility of the occurrence of a large event drives the need for SPE shielding for all deep space missions. The Advanced Exploration Systems (AES) RadWorks Storm Shelter Team was charged with developing minimal mass SPE storm shelter concepts for missions beyond LEO. The concepts developed included "wearable" shields, shelters that could be deployed at the onset of an event, and augmentations to the crew quarters. The radiation transport codes, human body models, and vehicle geometry tools contained in the On-Line Tool for the Assessment of Radiation In Space (OLTARIS) were used to evaluate the protection provided by each concept within a realistic space habitat and provide the concept designers with shield thickness requirements. Several different SPE models were utilized to examine the dependence of the shield requirements on the event spectrum. This paper describes the radiation analysis methods and the results of these analyses for several of the shielding concepts.

Walker, Steven A.↗

Radionuclide Inventory Threshold for Trench 31 and 34 Located Within the 200 West Area Low-Level Burial Grounds

Trenches 31 and 34 located in the 200 West Area Low-Level Burial Ground (LLBG) are authorized for disposal of low-level and mixed low-level radioactive waste under DOE Order 435.1, Radioactive Waste Management. A revised Disposal Authorization Statement was issued in October 2023 following approval of the performance assessment (PA) and supporting technical basis documents. To be consistent with approved PA calculations, the waste acceptance criteria (WAC) needs to be updated to include concentration limits for Category 1 (CAT1) and Category 3 (CAT3) waste along with the inventory limits. This environmental calculation file (ECF) provides the inventory limits for Category 1 and Category 3 waste disposal of radionuclides at Trench 31 and 34 based on the PA calculations. The concentration limits are not calculated as they are provided in the PA itself. The inventory thresholds (or limits) are calculated for only those radionuclides that are identified in the PA as the primary dose contributors. The primary dose contributors for the groundwater pathway are technetium-99, iodine-129, niobium-94, chlorine-36, molybdenum-93, and niobium-93m while those for the air pathway are tritium and carbon-14.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lunar base thermoelectric power station study

Under NASA's Project Prometheus, the Nuclear Systems Program, the Jet Propulsion Laboratory, Pratt & Whitney Rocketdyne, and Teledyne Energy Systems have teamed with a number of universities, under the Segmented Thermoelectric Multicouple Converter (STMC) program, to develop the next generation of advanced thermoelectric converters for space reactor power systems. Work on the STMC converter assembly has progressed to the point where the lower temperature stage of the segmented multicouple converter assembly is ready for laboratory testing and the upper stage materials have been identified and their properties are being characterized. One aspect of the program involves mission application studies to help define the potential benefits from the use of these STMC technologies for designated NASA missions such as the lunar base power station where kilowatts of power are required to maintain a permanent manned presence on the surface of the moon. A modular 50 kWe thermoelectric power station concept was developed to address a specific set of requirements developed for this mission. Previous lunar lander concepts had proposed the use of lunar regolith as in-situ radiation shielding material for a reactor power station with a one kilometer exclusion zone radius to minimize astronaut radiation dose rate levels. In the present concept, we will examine the benefits and requirements for a hermetically-sealed reactor thermoelectric power station module suspended within a man-made lunar surface cavity. The concept appears to maximize the shielding capabilities of the lunar regolith while minimizing its handling requirements. Both thermal and nuclear radiation levels from operation of the station, at its 100-m exclusion zone radius, were evaluated and found to be acceptable. Site preparation activities are reviewed and well as transport issues for this concept. The goal of the study was to review the entire life cycle of the unit to assess its technical problems and technology needs in all areas to support the development, deployment, operation and disposal of the unit.

space power↗

A New Shutdown Dose Rate Benchmark Problem for Representative Fusion Applications

Here, this work introduces a new benchmark problem for calculating shutdown dose rates (SDDRs) aimed at fusion reactor applications. The model is designed to represent a simplified version of a typical ITER port plug. The responses of interest include neutron flux, gamma flux, and gamma SDDR at 12 different locations scattered throughout the port. This article outlines the geometry specifications of the problem, provides material definitions for the components, specifies the required responses to be calculated, and presents the source definition information. The need for this benchmark arises from the limited availability of publicly accessible references, with only one benchmark representing the typical dimensions and materials found in fusion systems. This existing benchmark has been cited extensively, reflecting the demand within the scientific community to test both established and novel workflows for SDDR calculations. However, since its presentation at a conference in 2011, the results have become increasingly well known. Moreover, the absence of formal publication and peer review has led to the details of this benchmark being extracted from secondary sources, such as subsequent studies that reference it. As a result, analysts are left with significant flexibility in interpreting the key parameters, which can be adjusted to account for unknown systematic errors, ultimately reproducing the already well-known responses. This new benchmark serves as an updated version of that earlier work, with the aim of providing a more reliable description of the materials and their impurities, which is crucial for assessing activation and subsequent gamma emission. Additionally, it seeks to provide a geometry that more closely represents an ITER port plug. The improvements in the problem definition will lead to a more reproducible benchmark problem, while also presenting the radiation transport community with a completely new challenge. The results will be published in a future article to allow analysts adequate time to analyze this problem independently.

Benchmark↗

Back to functional hydrides: Effects of neutron-irradiated microstructure on hydrogen retention in yttrium hydride

Functional hydrides are promising candidates for advanced nuclear reactors, particularly in portable or transportable applications, due to their high hydrogen-retention capabilities, enabling efficient neutron moderation, and compact reactor design. However, hydrogen mobility in hydrides at elevated irradiation temperatures poses significant technological challenges, necessitating a comprehensive understanding of their irradiation behavior. Furthermore, this study investigated the microstructural and chemical stability of neutron-irradiated yttrium hydrides to assess their hydrogen-retention capacity. A targeted literature review was also conducted to contextualize neutron-irradiation effects on functional hydrides with regards to structural stability and hydrogen retention. Experimental characterizations revealed that, at high temperatures, irradiated hydrides retained their phase stability, which was likely enhanced by irradiation-induced microstructure evolution. Notably, an amorphous yttrium and oxygen -rich surface layer was present at the free surface of the hydride. Its thickness decreased while a continuous crystalline Y-O-rich layer was formed with increasing neutron damage. Additionally, the number density of dislocation loops and cavities generally increased as a function of neutron dose. First-principles calculations of hydrogen behavior within yttrium vacancy clusters in yttrium hydrides demonstrated vacancy-size-dependent hydrogen stability and configuration, highlighting the role of vacancy geometry in regulating hydrogen retention. Thus, the presence of irradiation-induced dislocation loops and cavities were hypothesized to improve hydrogen retention. Collectively, these findings advance the understanding of hydride behavior under neutron irradiation as well as their technological readiness for portable or transportable nuclear reactors.

Defect clusters↗

Spaceflight Autonomous Multigenerational Microbial Sequencer in Support of Plant-Growth Systems

The CubeSat platform has proven successful in obtaining meaningful life science information when biological payloads are incorporated. Examples include: 1) the first-ever CubeSat with a biological payload, GeneSat-1, which demonstrated decreased growth rates for flight samples of Escherichia coli in low Earth orbit (Parra et al. 2008); 2) PharmaSat, demonstrated that Saccharomyces cerevisiae in the microgravity environment exhibits a significant level of metabolic activity even at high doses of applied antifungal (Ricco et al. 2011); 3) O/OREOS, which used Bacillus subtilis(bacteria) to demonstrate for the first time that microorganisms can be loaded in a dried, dormant form and then rehydrated and grown in orbit months after launch (Nicholson et al. 2011; Ehrenfreund et al. 2014; 4) the SporeSat payload, which investigated Ceratopteris richardii(fern spores) using lab-on-a-chip devices (BioCDs) and minicentrifuges to produce artificial gravitational forces in ground studies (Park et al. 2017), with demonstration of the BioCD and minicentrifuge in space; 5) EcAMSat, the first CubeSat to be directly deployed from the ISS for an experiment assessing antibiotic resistance of E. coli in the microgravity environment (Padgen et al. 2020); 6) BioSentinel, exposed a culture of yeast to galactic cosmic radiation (GCR) and solar particle events while in heliocentric orbit to measure the rate of double-strand-break repair using DNA-repair-deficient mutants. This effort measures the metabolic parameters of yeast in a deep-space environment compared to Earth ambient conditions using a 3-color LED detection system (Ricco et al. 2020; Padgen et al. 2021). We aim to expand this list to include a Spaceflight Autonomous Multigenerational Microbial Sequencer (SAMMS). SAMMS will allow for the genome level understanding of changes in growth and metabolic activity for any organism. While microbes are suitable for early studies in our proposed platform because of their small size, small and relatively less-complicated genomes, fast generation times, and relevance to life support systems; multicellular organisms can similarly be evaluated for their genetic response to the spaceflight environment. The Spaceflight Autonomous Multigenerational Microbial Sequencer (SAMMS) will enable autonomous sequencing of biological samples in plant production units, cislunar orbit and on the lunar surface to examine spaceflight effects (ie. radiation, altered gravity, reduced pressures) on plant and microbial genomes.On this team a Kennedy Space Center (KSC) space crop production and water systems microbiologist/molecular biologist works with a Johnson Space Center (JSC) International Space Station (ISS) microbial sequencing expert and an Ames Research Center (ARC) CubeSat Engineering team to convert an automated Oxford Nanopore librarypreparation and sequencing method to a fluidic CubeSat payload system. The Oxford Nanopore MinION sequencing platform has proven successful in the spaceflight environment onboard the ISS (Stahl-Rommel et al. 2021). Further long-duration spaceflight and exposure to high levels of radiation will cause genotypic effects in biological organisms that may affect their function. Monitoring the adaption of a population to the spaceflight environment and any subsequent beneficial mutations will allow for the harnessing of organisms best suited for use in life support systems. This will ensure that the selected life support-essential microorganisms maintain their intended specified function over generations of culturing in the relevant spaceflight environment without becoming hazardous to crew or spacecraft systems.

Aubrie E Orourke↗

Assessment of thermal and radiation induced creep in the dual cooled lead lithium blanket

The creep in recently designed blanket for the fusion nuclear science facility is described by decomposing it into thermal, irradiation and cavity swelling creep. Initial estimates of thermal creep using elastic high temperature rules showed that the recent heat transfer improvements at the first wall (FW) is feasible, and the FW can withstand heat flux of 0.35 MW/m 2 at 3000 hrs without rupture. A viscoplastic model that is based on Norton's power law and relies on Multiphysics coupling of solid mechanics and heat transfer modules is used to capture the inelastic deformation in the blanket. Results showed that the design peak heat flux of 0.25 MW/m 2 produced maximum thermal creep strain of 0.45 % and the relaxation of the thermal stress at the FW. Irradiation creep is prescribed to be proportional to the displacement damage dose and applied stress. The displacements from irradiation creep radially decrease from the FW to the back wall, but the maximum deformation is found at the back wall that is connected to the Helium manifold due to the high stresses at the region. In conclusion, cavity swelling creep is dominant at steady state and combined with radiation creep to produce displacement of about 8 mm at the FW.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of Evidence Base from Medical Debriefs Data on Space Motion Sickness Incidence and Treatment

An objective of this data compilation and analysis project is to examine incidence and treatment efficacy of common patho-physiological disturbances during spaceflight. Analysis of medical debriefs data indicated that astronauts used medications to alleviate symptoms of four major ailments for which astronauts received treatment for sleep disturbances, space motion sickness (SMS), pain (headache, back pain) and sinus congestion. In the present data compilation and analysis project on SMS treatment during space missions, subject demographics (gender, age, first-time or repeat flyer), incidence and severity of SMS symptoms and subjective treatment efficacy from 317 crewmember debrief records were examined from STS-1 through STS-89. Preliminary analysis of data revealed that 50% of crew members reported SMS symptoms on at least one flight and 22% never experienced it. In addition, there were 387 medication dosing episodes reported, and promethazine was the most commonly used medication. Results of analysis of symptom check lists, medication use/efficacy and gender and flight record differences in incidence and treatment efficacy will be presented. Evidence gaps for treatment efficacy along with medication use trend analysis will be identified.

Younker, D.R.↗

Advanced Multifunctional MMOD Shield: Radiation Shielding Assessment

As NASA is looking to explore further into deep space, multifunctional materials are a necessity for decreasing complexity and mass. One area where multifunctional materials could be extremely beneficial is in the micrometeoroid orbital debris (MMOD) shield. A typical MMOD shield on the International Space Station (ISS) is a stuffed whipple shield consisting of multiple layers. One of those layers is the thermal blanket, or multi-layer insulation (MLI). By increasing the MMOD effectiveness of MLI blankets, while still preserving their thermal capabilities, could allow for a less massive MMOD shield. Thus, a study was conducted to evaluate concept MLI blankets for MMOD shields. In conjunction, these MLI blankets and the subsequent MMOD shields were also evaluated for their radiation shielding effectiveness towards protecting crew. These concepts were evaluated against the ISS MLI blankets and the ISS MMOD shield, which acted as the baseline. These radiation shielding assessments were performed using the high charge and energy transport software (HZETRN). This software is based on a one-dimensional formula of the Boltzmann transport equation with a straight-ahead approximation. Each configuration was evaluated against the following environments to provide a diverse view of radiation shielding effectiveness in most space environments within the heliosphere: August 1972 solar particle event, October 1989 solar particle event, 1982 galactic cosmic ray environment (during solar maximum), 1987 galactic cosmic ray environment (during solar minimum), and a low earth orbit environment in 1970 that corresponded to an altitude of 400 km and inclination of 51.6 . Both the absorbed dose and the dose equivalent were analyzed, but the focus of the discussion was on the dose equivalent since the data is most concerned with radiation shielding of the crew. The following paper outlines the evaluations performed and discusses the results and conclusions of this evaluation for radiation shielding effectiveness. Future work will focus on optimizing the radiation shielding properties for the MMOD shield. Submission

Rojdev, Kristina↗

Efficiency of a radiophotoluminescence glass dosemeter for low-earth-orbit space radiation

Chips of a radiophotoluminescence glass dosemeter (RPLG) were used for measurements of space radiation during a 9.8 d Shuttle-Mir mission (STS-91) at an altitude of 400 km and an inclination of 51.65 degrees. Two of RPLG chips were put into each of 59 positions in or on a life-size human phantom. The RPLG values equivalent to 137Cs gamma ray absorbed doses were found to be systematically lower than those of a Mg2SiO4:Tb thermoluminescence dosemeter (TDMS). In comparison with the organ or tissue absorbed dose and dose equivalent values that were estimated using a combination of TDMS and plastic nuclear track detectors, the efficiencies of the RPLG chips were about 80% for the water absorbed dose and about 40% for the dose equivalent. Whereas the percentage values will change during different missions, such additional information obtained from small RPLG chips is useful for improving the reliability of radiation dosimetry in space.