Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Defect detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Early Results from GLASS-JWST. II. NIRCam Extragalactic Imaging and Photometric Catalog

We present the reduced images and multiwavelength catalog of the first JWST NIRCam extragalactic observations from the GLASS Early Release Science Program, obtained as coordinated parallels of the NIRISS observations of the Abell 2744 cluster. Images in seven bands (F090W, F115W, F150W, F200W, F277W, F356W, and F444W) have been reduced using an augmented version of the official JWST pipeline; we discuss the procedures adopted to remove or mitigate defects in the raw images. We obtain a multiband catalog by means of forced aperture photometry on point-spread function (PSF)-matched images at the position of F444W-detected sources. The catalog is intended to enable early scientific investigations, and it is optimized for faint galaxies; it contains 6368 sources, with limiting magnitude 29.7 at 5 σ in F444W. We release both images and catalog in order to allow the community to become familiar with the JWST NIRCam data and evaluate their merit and limitations given the current level of knowledge of the instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

Terahertz Imaging and Backscatter Radiography Probability of Detection Study for Space Shuttle Foam Inspections

This slide presentation reviews the use of terahertz imaging and Backscatter Radiography in a probability of detection study of the foam on the external tank (ET) shedding and damaging the shuttle orbiter. Non-destructive Examination (NDE) is performed as one method of preventing critical foam debris during the launch. Conventional NDE methods for inspection of the foam are assessed and the deficiencies are reviewed. Two methods for NDE inspection are reviewed: Backscatter Radiography (BSX) and Terahertz (THZ) Imaging. The purpose of the Probability of Detection (POD) study was to assess performance and reliability of the use of BSX and or THZ as an appropriate NDE method. The study used a test article with inserted defects, and a sample of blanks included to test for false positives. The results of the POD study are reported.

Ussery, Warren↗

First constraints on causal sources of primordial gravitational waves from BICEP/Keck, SPTpol, SPT-3G, Planck and WMAP $B$-mode data

Non-inflationary sources of gravitational waves in the early Universe generically predict causality-limited tensor power spectra at low frequencies. We report the first-ever constraints on such sources based on cosmic microwave background (CMB) $B$-mode polarization measurements. Using data from BICEP/Keck, SPTpol, SPT-3G, Planck, and WMAP, we constrain the amplitude of an early causal tensor (ECT) power spectrum parameterized by $r_{ect}$, the ratio of causal tensor power to total scalar power at $k~=~0.01$ Mpc$^{-1}$, and obtain a 95% CL upper limit of $r_{ect}<$ 0.0077. Since $r_{ect}$ can easily be related to the parameters of a given theory, our bound robustly constrains a broad class of well-motivated gravitational wave sources in the early universe, including first-order cosmological phase transitions, enhanced small-scale density perturbations, and various topological defects. Finally, we translate our limit into a bound on the present-day energy density in gravitational waves at ultra-low frequencies otherwise inaccessible to traditional gravitational wave detection strategies, including pulsar timing arrays, interferometers, and resonant cavities.

Zebrowski, Jessica A. [Fermilab; Chicago U., KICP]↗

Optical activation and detection of charge transport between individual colour centres in diamond

Understanding the capture of charge carriers by colour centres in semiconductors is important for the development of novel forms of sensing and quantum information processing, but experiments typically involve ensemble measurements, often impacted by defect proximity. In this study, we show that confocal fluorescence microscopy and magnetic resonance can be used to induce and probe charge transport between individual nitrogen-vacancy centres in diamond at room temperature. In our experiments, a ‘source’ nitrogen vacancy undergoes optically driven cycles of ionization and recombination to produce a stream of photogenerated carriers, one of which is subsequently captured by a ‘target’ nitrogen vacancy several micrometres away. We use a spin-to-charge conversion scheme to encode the spin state of the source colour centre into the charge state of the target, which allows us to set an upper bound to carrier injection from other background defects. We attribute our observations to the action of unscreened Coulomb potentials producing giant carrier capture cross-sections, orders of magnitude greater than those measured in ensembles.

36 MATERIALS SCIENCE↗

Transient Studies of CO 2 Adsorption over CeO 2 Nanostructures with In Situ DRIFTS and Modulation Excitation

Experiments of in-situ DRIFTS combined with modulation excitation (ME) spectroscopy showed a rich surface chemistry associated with the adsorption of CO 2 on nanocubes and nanospheres of ceria. The nanocubes exposed faces with a (100) orientation, with the edges and corners displaying (110) and (111) orientations, respectively. Here, the nanospheres mainly contained ceria (111) and (110) planes. DFT calculations showed that CO 2 is a multidentate adsorbate on ceria that can undergo changes in its bonding configuration depending on the chemical environment. At 250 °C, a temperature typically used for the conversion of CO 2 into oxygenates, alkanes and olefins, CO 2 reacted with O centers or OH groups present on the nanocubes and nanospheres to yield bi- and tri-dentate carbonates, hydroxycarbonates, and formates. Both nanostructures were highly reactive and a dynamic equilibrium was established: carbonate species were rapidly generated upon the injection of CO 2 and they decomposed upon the removal of CO 2 from the gas phase. In the case of the ceria nanocubes, the adsorption/desorption processes were essentially reversible, opening the door to catalytic transformations. A larger concentration of defects in the ceria nanospheres led to strongly bound carbonates and formates that may be spectators, site blockers, or surface modifiers in catalytic processes. In the ME studies, additional intermediates were detected, and it was clear that the response of surface species to the presence/absence of CO 2 was highly dependent on the morphology of the ceria nanostructures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parallel pumping of magnons in inhomogeneous spin textures probed through NV spin relaxometry

We combine micromagnetic simulations and nitrogen-vacancy (NV) defect center spin relaxometry measurements to study magnon modes in inhomogeneous spin textures. A thin, micrometer-scale ferromagnetic disk is magnetized in a vortex state in which the magnetization curls around a central core. Micromagnetic simulations show that at zero applied field, the magnetization dynamics of the disk consist of a low frequency gyrotropic mode and higher frequency azimuthal magnon modes, all far detuned from the NV spin transition frequencies. An in-plane static magnetic field breaks the azimuthal symmetry of the vortex state, resulting in the magnon modes transforming in frequency and spatial profile as the field increases. Experimentally, we probe the dynamics of vortex magnetization as a function of applied in-plane static field and ac driving frequency by optically monitoring a nearby NV defect center spin. At certain values of the applied magnetic field, we observe enhanced spin relaxation when driving at twice the frequency of the NV ground state spin transition in optically detected magnetic resonance measurements. We attribute this effect to parallel pumping of a magnon mode in the disk producing magnons at half the excitation frequency. Micromagnetic simulations support this finding, showing spatial and spectral overlap of a confined magnon mode and an NV spin transition, with sufficient interaction strength to explain the observed signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vision inspection system and method

An optical vision inspection system (4) and method for multiplexed illuminating, viewing, analyzing and recording a range of characteristically different kinds of defects, depressions, and ridges in a selected material surface (7) with first and second alternating optical subsystems (20, 21) illuminating and sensing successive frames of the same material surface patch. To detect the different kinds of surface features including abrupt as well as gradual surface variations, correspondingly different kinds of lighting are applied in time-multiplexed fashion to the common surface area patches under observation.

Huber, Edward D.↗

Anomaly Detection Techniques with Real Test Data from a Spinning Turbine Engine-Like Rotor

Online detection techniques to monitor the health of rotating engine components are becoming increasingly attractive to aircraft engine manufacturers in order to increase safety of operation and lower maintenance costs. Health monitoring remains a challenge to easily implement, especially in the presence of scattered loading conditions, crack size, component geometry, and materials properties. The current trend, however, is to utilize noninvasive types of health monitoring or nondestructive techniques to detect hidden flaws and mini-cracks before any catastrophic event occurs. These techniques go further to evaluate material discontinuities and other anomalies that have grown to the level of critical defects that can lead to failure. Generally, health monitoring is highly dependent on sensor systems capable of performing in various engine environmental conditions and able to transmit a signal upon a predetermined crack length, while acting in a neutral form upon the overall performance of the engine system.

Abdul-Aziz, Ali↗

Nitrogen Vacancy Centers in Diamond for Stress Sensing Applications: Theory and Experiments

Sensing of stress under high elevated environmental conditions with high resolution has critical importance for range of applications including earth’s subsurface scanning and geological CO2 storage monitoring. Using first principles density functional theory (DFT) approach combined with the theoretical modelling of low energy Hamiltonian, here we investigate a novel approach to detect unprecedented level of pressure by taking advantage of solid-state electron’s spin of Nitrogen vacancy (NV) centers in nanodiamond. We computationally explore the effect of strain on the defect band edges and band gaps by varying the lattice parameters of diamond supercell hosting a single NV center. A low energy Hamiltonian is developed that includes effect of stress on the energy level of ±1 spin manifold at the ground state. By quantifying the energy level shift and split, we predict the pressure sensing of up to 0.3 MPa/√Hz. We show superiority of the quantum sensing over traditional optical sensing techniques by discussing our results from DFT and theoretical modelling for the frequency shift per unit pressure. The proposed quantum stress sensing could be useful to measure earth’s subsurface vibrations. Our results open avenues for development of sensing technology with a high sensitivity and resolution under extreme pressure conditions that potentially has a wider applicability than existing pressure sensing technologies.

Paudel, Hari P.↗

In Situ Ion Counting for Improved Implanted Ion Error Rate and Silicon Vacancy Yield Uncertainty

An in situ counted ion implantation experiment improving the error on the number of ions required to form a single optically active silicon vacancy (SiV) defect in diamond 7-fold compared to timed implantation is presented. Here, traditional timed implantation relies on a beam current measurement followed by implantation with a preset pulse duration. It is dominated by Poisson statistics, resulting in large errors for low ion numbers. Instead, our in situ detection, measuring the ion number arriving at the substrate, results in a 2-fold improvement of the error on the ion number required to generate a single SiV compared to timed implantation. Through postimplantation analysis, the error is improved 7-fold compared to timed implantation. SiVs are detected by photoluminescence spectroscopy, and the yield of 2.98% is calculated through the photoluminescence count rate. Hanbury–Brown–Twiss interferometry is performed on locations potentially hosting single-photon emitters, confirming that 82% of the locations exhibit single photon emission statistics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Van der Waals Nanowires with Continuously Variable Interlayer Twist and Twist Homojunctions

Abstract Moiré patterns at van der Waals interfaces between twisted 2D crystals give rise to distinct optoelectronic excitations, as well as, narrowly dispersive bands responsible for correlated electron phenomena. Contrasting with the conventional, mechanically stacked planar twist moirés, recent work shows twisted van der Waals interfaces spontaneously formed in nanowires of layered crystals, where Eshelby twist due to axial screw dislocations stabilizes a chiral structure with small interlayer rotation. Here, the realization of tunable twist in germanium(II) sulfide (GeS) van der Waals nanowires is reported. Tapered nanowires host continuously variable interlayer twist. Homojunctions between dislocated (chiral) and defect‐free (achiral) segments are obtained by triggering the emission of axial dislocations during growth. Measurements across such junctions, implemented here using local absorption and luminescence spectroscopy, provide a convenient tool for detecting twist effects. The results identify a versatile system for 3D twistronics, probing moiré physics, and for realizing moiré architectures without equivalent in planar systems.

Sutter, Peter↗

Effects of excess Te on flux inclusion formation in the growth of cadmium zinc telluride when forced melt convection is applied

The presence of second phase defects, particularly flux inclusions of tellurium rich composition, are of great concern for charge collection efficiency in cadmium zinc telluride (CZT) and cadmium telluride (CT) material intended for applications such as radiation detection. These inclusions can distort applied electric field lines within the detector as well as act as trapping centers for charge carriers. Reduction and/or elimination of these inclusions is required to achieve appropriate charge collection efficiencies, especially in detectors of thicknesses greater than 5 mm. These so-called flux inclusions are understood to form as a consequence of constitutional undercooling at the crystal growth interface. In this study, a forced melt convection technique was applied in Vertical Bridgman (VB) melt growth of CZT without reducing imposed growth rates of ~2 mm/hr. Several rotation profiles were tested while adjusting the melt composition from 51.62 to 61.75 atomic percent (at%) Te where the Te concentration was initially increased to improve overall material purity. With forced melt convection, the best inclusion distributions were achieved with highly Te rich melt compositions, far beyond the stoichiometric composition range for the CZT system. Average inclusion diameters were reduced to 2 µm while inclusions greater than 5 µm were essentially eliminated. Composition analyses of these ingots revealed near equilibrium concentrations of Te, even with ingots grown from Te concentrations as high as 61.75 at% Te. In this paper, a recipe for the reduction of inclusions in CZT melt growth is put forward and the implications of this method on our understanding of inclusion formation are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NDE standards for high temperature materials

High temperature materials include monolithic ceramics for automotive gas turbine engines and also metallic/intermetallic and ceramic matrix composites for a range of aerospace applications. These are materials that can withstand extreme operating temperatures that will prevail in advanced high-efficiency gas turbine engines. High temperature engine components are very likely to consist of complex composite structures with three-dimensionality interwoven and various intermixed ceramic fibers. The thermomechanical properties of components made of these materials are actually created in-place during processing and fabrication stages. The complex nature of these new materials creates strong incentives for exact standards for unambiguous evaluations of defects and microstructural characteristics. NDE techniques and standards that will ultimately be applicable to production and quality control of high temperature materials and structures are still emerging. The needs range from flaw detection to below 100 micron levels in monolithic ceramics to global imaging of fiber architecture and matrix densification anomalies in composites. The needs are different depending on the processing stage, fabrication method, and nature of the finished product. The standards are discussed that must be developed in concert with advances in NDE technology, materials processing research, and fabrication development. High temperature materials and structures that fail to meet stringent specifications and standards are unlikely to compete successfully either technologically or in international markets.

Vary, Alex↗

Biotelemetry

Sensors 2000! is developing pill-shaped biotelemeters for measuring physiological parameters during space flight life sciences experiments using rodents aboard the ISS Gravitational Biology Facility, with the additional capability for monitoring the health of astronauts in the Human Research Facility. The first "pill transmitter" is capable of measuring pressure and temperature for up to 10 months. The NASA objective is to utilize these devices. The pill-transmitters can also be used by non-NASA users for medical applications. One application is fetal surgery. The 44pill" is small enough to be endoscopically placed into the womb through a tube used during surgeries to correct fetal defects before birth. After surgery, the pill-transmitter will continue to monitor body temperature, pressure and other vital signs in the womb, radioing results to physicians. It will help them to detect preterm-labor, a serious problem after fetal surgery. The pill is about one-third-of-an-inch across and one-and-one-third-inches long. Future pill-versions will include pH, heartrate, and ECG. A pH-pill prototype is currently being tested. Sensors 2000! has also designed and built a 2-channel biotelemetry receiver and has developed data acquisition software to display and record the measured physiological parameters. A DSP-base hand-held receiver (trisponder) is currently under development.

Mundt, C.↗

Scalable Parallel Measurement of Individual Nitrogen-Vacancy Centers

The nitrogen-vacancy (NV) center in diamond is a solid-state spin defect that has been widely adopted for quantum sensing and quantum information processing applications. Typically, experiments are performed either with a single isolated NV center or with an unresolved ensemble of many NV centers, resulting in a trade-off between measurement speed and spatial resolution or control over individual defects. In this work, we introduce an experimental platform that bypasses this trade-off by addressing multiple optically resolved NV centers in parallel. We perform charge- and spin-state manipulations selectively on multiple NV centers from within a larger set, and we manipulate and measure the electronic spin states of over 100 NV centers in parallel. We show that the high signal-to-noise ratio of the measurements enables the detection of shot-to-shot pairwise correlations between the spin states of 108 NV centers, corresponding to the simultaneous measurement of 5778 unique correlation coefficients. We discuss how our platform can be scaled to parallel experiments with thousands of individually resolved NV centers. These results enable parallelized high-throughput sensing experiments that retain the spatial resolution of single defects and will, thereby, help to unlock advances in applications such as single-molecule NMR and characterization of integrated circuits. In addition, our approach to multiplexing provides a natural platform for the application of recently developed correlated sensing techniques.

NV centers↗

Updates to Relevance Vector Machine: Multiclass Classification, Variable Selection, and Proof-of-Concept Application to Safeguards Fresh Fuel Verification using List-Mode Neutron Collar Data

To expand the capabilities of safeguards authorities to verify the integrity of fresh fuel assemblies, Oak Ridge National Laboratory has retrofit the existing electronics of the JCC-71 uranium neutron coincidence collar, which contains 18 3 He neutron detectors and an external 241 AmLi(α, n) neutron interrogation source arranged to surround a fresh nuclear fuel assembly. The new electronics system allows analysts to record list-mode neutron multiplicity data in addition to the singles and doubles rates that are currently measured. Based on previous proof-of-concept research, analysis of these new data will identify off-normal fuel configurations in an assembly and characterize or localize the specific partial fuel defects. The purpose of this report it to document the analysis algorithm development and then to demonstrate its capability for the safeguards verification of fresh fuel assemblies using list mode neutron collar data. To analyze the complex list-mode data collected with the upgraded uranium neutron collar, multivariate classification algorithms are being developed using a novel classification method, the relevance vector machine. This approach may be applied to multiclass problems to estimate the probability that test data belongs to one of many possible classes of data. In addition, our method identifies the most useful variables/channels for making predictions, which illuminates the basis for the model’s predictions, and this interpretability is largely unique among data analytics methods. Variable selection occurs during model training and parameter tuning and does not need any external hyperparameter tuning routines. Finally, we apply the modified relevance vector machine to a simulated dataset of list-mode neutron collar data generated with the radiation transport code MCNP. The method can correctly identify off-normal fuel configurations, categorize the data according to four fuel defect scenarios, and rank the channels in the data according to prediction utility. For nuclear safeguards applications, it is concluded that this method has the potential to increase the sensitivity and reliability to detect missing fuel rods from a standard 17 x 17 Pressurized Water Reactor (PWR) fresh fuel assembly. Within this analysis, “off-normal” (i.e., missing fuel rods) were correctly classified in 17 simulated test scenarios with one quarter (25%) of the fresh fuel rods missing using a training data set of 58 simulated measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computed Tomography For Internal Inspection Of Castings

Computed tomography used to detect internal flaws in metal castings before machining and otherwise processing them into finished parts. Saves time and money otherwise wasted on machining and other processing of castings eventually rejected because of internal defects. Knowledge of internal defects gained by use of computed tomography also provides guidance for changes in foundry techniques, procedures, and equipment to minimize defects and reduce costs.

Hanna, Timothy L.↗

Impact of Oxygen Non-Stoichiometry on Near-Ambient Temperature Ionic Mobility in Polaronic Mixed-Ionic-Electronic Conducting Thin Films

Enhanced ionic mobility in mixed ionic and electronic conducting solids contributes to improved performance of memristive memory, energy storage and conversion, and catalytic devices. Ionic mobility can be significantly depressed at reduced temperatures, for example, due to defect association and therefore needs to be monitored. Measurements of ionic transport in mixed conductors, however, proves to be difficult due to dominant electronic conductivity. This study examines the impact of different levels of quenched-in oxygen deficiency on the oxygen vacancy mobility near room temperature as measured by a novel dynamic current-voltage analysis. A Pr 0.1 Ce 0.9 O 2-δ film was grown by pulsed laser deposition and subsequently annealed, from 400-600° C, in various oxygen partial pressures to modify its oxygen vacancy concentration while minimizing microstructural growth and cation segregation. To monitor changes in film non-stoichiometry, we leverage the existence of an optical absorption center, related to the oxidation state of Pr ions in Pr0.1Ce0.9O2-δ. The oxygen vacancy migration enthalpy was found to exhibit a small increase from 0.73± 0.04 to 0.79 ± 0.02 eV with increasing oxygen deficiency, while the pre-factor was found to increase by a factor of 135. Here, a nearly 13-fold increase in ionic mobility at 60 °C for increases in oxygen non-stoichiometry from 0.032 ± 0.001 to 0.042± 0.001 was thereby detected. Raman spectroscopy was employed to rule out changes in strain as the primary cause for the significant change in mobility. Several factors potentially contributing to the large pre-factor changes are examined and discussed. Insights into how ionic defect concentration can markedly impact ionic mobility should help in elucidating the origins of variations seen in nanoionic devices.

36 MATERIALS SCIENCE↗