Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data acquisition systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Beam Stability R&D for the APS MBA Upgrade

Beam diagnostics required for the APS Multi-bend acromat (MBA) are driven by ambitious beam stability requirements. The major AC stability challenge is to correct rms beam motion to 10% the rms beam size at the insertion device source points from0.01 to 1000 Hz. The vertical plane represents the biggest challenge forAC stability, which is required to be 400 nm rms for a 4-micron vertical beam size. In addition to AC stability, long-term drift over a period of seven days is required to be 1 micron or less. Major diagnostics R&D components include improved rf beam position processing using commercially available FPGA-based BPM processors, new X-ray beam position monitors based on hard X-ray fluorescence from copper and Compton scattering off diamond, mechanical motion sensing to detect and correct long-term vacuum chamber drift, a new feedback system featuring a tenfold increase in sampling rate, and a several-fold increase in the number of fast correctors and BPMs in the feedback algorithm. Feedback system development represents a major effort, and we are pursuing development of a novel algorithm that integrates orbit correction for both slow and fast correctors down to DC simultaneously. Finally, a new data acquisition system (DAQ) is being developed to simultaneously acquire streaming data from all diagnostics as well as the feedback processors for commissioning and fault diagnosis. Results of studies and the design effort are reported.

APS MBA Upgrade↗

A micron resolution optical scanner for characterization of silicon detectors

The emergence of high position resolution (∼10 μm) silicon detectors in recent times have highlighted the urgent need for the development of new automated optical scanners of micron level resolution suited for characterizing microscopic features of these detectors. More specifically, for the newly developed silicon photo-multipliers (SiPM) that are compact, possessing excellent photon detection efficiency with gain comparable to photo-multiplier tube. In a short time, since their invention the SiPMs are already being widely used in several high-energy physics and astrophysics experiments as the photon readout element. The SiPM is a high quantum efficiency, multi-pixel photon counting detector with fast timing and high gain. The presence of a wide variety of photo sensitive silicon detectors with high spatial resolution requires their performance evaluation to be carried out by photon beams of very compact spot size. We have designed a high resolution optical scanner that provides a monochromatic focused beam on a target plane. The transverse size of the beam was measured by the knife-edge method to be 1.7 μm at 1 − σ level. Since the beam size was an order of magnitude smaller than the typical feature size of silicon detectors, this optical scanner can be used for selective excitation of these detectors. The design and operational details of the optical scanner, high precision programmed movement of target plane (0.1 μm) integrated with general purpose data acquisition system developed for recording static and transient response photo sensitive silicon detector are reported in this paper. Entire functionality of scanner is validated by using it for selective excitation of individual pixels in a SiPM and identifying response of active and dead regions within SiPM. Results from these studies are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Considerations for Large Mass Ultra-Low Background Experiments

Summary The objective of this document is to present the designers of the next generation of large-mass, ultra-low background experiments with lessons learned and design strategies from previous experimental work. Design issues divided by topic into mechanical, thermal and electrical requirements are addressed. Large mass low-background experiments have been recognized by the scientific community as appropriate tools to aid in the refinement of the standard model. The design of these experiments is very costly and a rigorous engineering review is required for their success. The extreme conditions that the components of the experiment must withstand (heavy shielding, vacuum/pressure and temperature gradients), in combination with unprecedented noise levels, necessitate engineering guidance to support quality construction and safe operating conditions. Physical properties and analytical results of typical construction materials are presented. Design considerations for achieving ultra-low-noise data acquisition systems are addressed. Five large-mass, low-background conceptual designs for the one-tonne scale germanium experiment are proposed and analyzed. The result is a series of recommendations for future experiments engineering and for the Majorana simulation task group to evaluate the different design approaches.

1TGe One-tonne 76Ge neutrinoless double beta-decay↗

An active drop counting device using condenser microphone for superheated emulsion detector

An active device for superheated emulsion detector is described. A capacitive diaphragm sensor or condenser microphone is used to convert the acoustic pulse of drop nucleation to electrical signal. An active peak detector is included in the circuit to avoid multiple triggering of the counter. The counts are finally recorded by a microprocessor based data acquisition system. Genuine triggers, missed by the sensor, were studied using a simulated clock pulse. The neutron energy spectrum of {sup 252}Cf fission neutron source was measured using the device with R114 as the sensitive liquid and compared with the calculated fission neutron energy spectrum of {sup 252}Cf. Frequency analysis of the detected signals was also carried out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field trials results of guided wave tomography

Corrosion is one of the industries major issues regarding the integrity of assets. Guided wave travel time tomography is a method capable of providing an absolute wall thickness map. This method is currently making the transition from the laboratory to the field. For this purpose a dedicated data acquisition system and special purpose EMAT sensor rings have been developed. The system can be deployed for permanent monitoring and inspections. Field trials have been conducted on various pipes with different diameters, containing either liquid or gas. The main focus has been on pipe supports. The results demonstrate the successful operation of the technology in the field. Expected corrosion damage was clearly visible on the produced results enabling asset owner to make calculated decisions on the pipelines safety, maintenance and operations.

42 ENGINEERING↗

IceCube: An Instrument for Neutrino Astronomy

Neutrino astronomy beyond the Sun was first imagined in the late 1950s; by the 1970s, it was realized that kilometer-scale neutrino detectors were required. The first such instrument, IceCube, is near completion and taking data. The IceCube project transforms a cubic kilometer of deep and ultra-transparent Antarctic ice into a particle detector. A total of 5,160 optical sensors are embedded into a gigaton of Antarctic ice to detect the Cherenkov light emitted by secondary particles produced when neutrinos interact with nuclei in the ice. Each optical sensor is a complete data acquisition system, including a phototube, digitization electronics, control and trigger systems and LEDs for calibration. The light patterns reveal the type (flavor) of neutrino interaction and the energy and direction of the neutrino, making neutrino astronomy possible. The scientific missions of IceCube include such varied tasks as the search for sources of cosmic rays, the observation of Galactic supernova explosions, the search for dark matter, and the study of the neutrinos themselves. These reach energies well beyond those produced with accelerator beams.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-111: Development of Proton Dosimetry System Using Fiber-Optic Cerenkov Radiation Sensor Array

Purpose: We had developed and evaluated a new dosimetric system for proton therapy using array of fiber-optic Cerenkov radiation sensor (FOCRS) which can measure a percent depth dose (PDD) instantly. In this study, the Bragg peaks and spread out Bragg peak (SOBP) of the proton beams measured by FOCRS array were compared with those measured by an ion chamber. Methods and Method: We fabricated an optical fiber array of FOCRS in a handmade phantom which is composed of poly-methyl methacrylate (PMMA). There are 75 holes of 1mm diameter inside the phantom which is designed to be exposed in direction of beam when it is emerged in water phantom. The proton beam irradiation was carried out using IBA cyclotron PROTEUS 235 at national cancer center in Korea and a commercial data acquisition system was used to digitize the analog signal. Results: The measured Bragg peak and SOBP for the proton ranges of 7∼ 20 cm were well matched with the result from ion chamber. The comparison results show that the depth of proton beam ranges and the width of SOBP measured by array of FOCRS are comparable with the measurement from multi-layer ion chamber (MLIC) although there are some uncertainty in the measurement of FOCRS array for some specific beam ranges. Conclusion: The newly developed FOCRS array based dosimetric system for proton therapy can efficiently reduce the time and effort needed for proton beam range measurement compared to the conventional method and has the potential to be used for the proton pencil beam application.

07 ISOTOPE AND RADIATION SOURCES↗

WE-D-BRF-03: Proton Beam Range Verification with a Single Prompt Gamma-Ray Detector

Purpose: To present an experimental study of a novel range verification method for scanned and scattered proton beams. Methods: A detection system consisting of an actively shielded lanthanum(III)bromide scintillator and a one-sided lead collimator was used to measure prompt gamma-rays emitted during the delivery of proton beams to a water phantom and an anthropomorphic head phantom. The residual proton range at the collimator position was determined by comparing gamma-ray intensities while the proton energy was modulated to the distal end of the target. We used a clinical field to deliver a 50 cGy dose to a 12 cm diameter target in the water phantom and to a 175 cc tumor-shaped target in the head phantom. The detector signals were acquired with a custom data acquisition system enabling energy and time-of-flight discrimination of prompt gamma-rays. Results: Range deviations were detected with a statistical accuracy of ± 0.2 mm and ± 1.4 mm at 90% confidence level, respectively for the water and head phantom. We obtained a time resolution of 1 ns FWHM and an energy resolution < 2% FWHM for the main gamma lines from proton-induced nuclear reactions with carbon and oxygen. This allowed for an accurate separation of the prompt gamma-rays from neutron-induced background. Conclusion: Proton range deviations can be detected with millimeter accuracy using a single prompt gamma-ray measurement point acquired during the delivery of a few proton energy layers to the distal part of the target. The method is also feasible in the presence of background radiation from passively scattered proton beam delivery.

60 APPLIED LIFE SCIENCES↗

Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab

The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped Gd 2 SiO 5 crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Langmuir probe diagnostics of plasma in high current electron cyclotron resonance proton ion source

A high current Electron Cyclotron Resonance (ECR) proton ion source has been developed for low energy high intensity proton accelerator at Bhabha Atomic Research Centre. Langmuir probe diagnostics of the plasma generated in this proton ion source is performed using Langmuir probe. The diagnostics of plasma in the ion source is important as it determines beam parameters of the ion source, i.e., beam current, emittance, and available species. The plasma parameter measurement in the ion source is performed in continuously working and pulsed mode using hydrogen as plasma generation gas. The measurement is performed in the ECR zone for operating pressure and microwave power range of 10{sup −4}–10{sup −3} mbar and 400–1000 W. An automated Langmuir probe diagnostics unit with data acquisition system is developed to measure these parameters. The diagnostics studies indicate that the plasma density and plasma electron temperature measured are in the range 5.6 × 10{sup 10} cm{sup −3} to 3.8 × 10{sup 11} cm{sup −3} and 4–14 eV, respectively. Using this plasma, ion beam current of tens of mA is extracted. The variations of plasma parameters with microwave power, gas pressure, and radial location of the probe have been studied.

43 PARTICLE ACCELERATORS↗

Energy resolution of gamma-ray spectroscopy of JET plasmas with a LaBr{sub 3} scintillator detector and digital data acquisition

A new high efficiency, high resolution, fast {gamma}-ray spectrometer was recently installed at the JET tokamak. The spectrometer is based on a LaBr{sub 3}(Ce) scintillator coupled to a photomultiplier tube. A digital data acquisition system is used to allow spectrometry with event rates in excess of 1 MHz expected in future JET DT plasmas. However, at the lower rates typical of present day experiments, digitization can degrade the energy resolution of the system, depending on the algorithms used for extracting pulse height information from the digitized pulses. In this paper, the digital and analog spectrometry methods were compared for different experimental conditions. An algorithm based on pulse shape fitting was developed, providing energy resolution equivalent to the traditional analog spectrometry method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-element CZT array for nuclear safeguards applications

To address drawbacks of a CZT detector due to its limited size, a dual-CZT array, consisting of two CZT detectors and a DAS (Data Acquisition System), was constructed and algorithm to handle the spectra from the CZT array was discussed in this study. Spectra of 4.5% enriched UO{sub 2} powder were obtained using the dual-CZT array. The detection efficiency acquired by the CZT array was about twice higher than that of a single CZT spectra, while FWHMs are nearly identical (about 7.0 keV) for each spectrum. The results of this study show that a much better detection efficiency of CZT can be achieved without degrading its energy resolution. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ALDAS user's manual

The Acoustic Laboratory Data Acquisition System (ALDAS) is an inexpensive, transportable means to digitize and analyze data. The system is based on the Macintosh 2 family of computers, with internal analog-to-digital boards providing four channels of simultaneous data acquisition at rates up to 50,000 samples/sec. The ALDAS software package, written for use with rotorcraft acoustics, performs automatic acoustic calibration of channels, data display, two types of cycle averaging, and spectral amplitude analysis. The program can use data obtained from internal analog-to-digital conversion, or discrete external data imported in ASCII format. All aspects of ALDAS can be improved as new hardware becomes available and new features are introduced into the code.

Watts, Michael E.↗

New portable instrument for the measurement of thermal conductivity in gas process conditions

The development of high temperature gas sensors for the monitoring and determination of thermophysical properties of complex process mixtures at high temperatures faces several problems, related with the materials compatibility, active sensing parts sensitivity, and lifetime. Ceramic/thin metal films based sensors, previously developed for the determination of thermal conductivity of molten materials up to 1200 °C, were redesigned, constructed, and applied for thermal conductivity measuring sensors. Platinum resistance thermometers were also developed using the same technology, to be used in the temperature measurement, which were also constructed and tested. A new data acquisition system for the thermal conductivity sensors, based on a linearization of the transient hot-strip model, including a portable electronic bridge for the measurement of the thermal conductivity in gas process conditions was also developed. The equipment is capable of measuring the thermal conductivity of gaseous phases with an accuracy of 2%-5% up to 840 °C (95% confidence level). The development of sensors up to 1200 °C, present at the core of the combustion chambers, will be done in a near future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vexcel Spells Excellence for Earth and Space

With assistance from Stennis Space Center, Vexcel was able to strengthen the properties of its Apex Ground Station(TM), an affordable, end-to-end system that comes complete with a tracking antenna that permits coverage within an approximate 2,000-kilometer radius of its location, a high speed direct-to-disk data acquisition system that can download information from virtually any satellite, and data processing software for virtually all synthetic aperture radar and optical satellite sensors. Vexcel is using an Apex system linked to the Terra satellite to help scientists and NASA personnel measure land and ocean surface temperatures, detect fires, monitor ocean color and currents, produce global vegetation maps and data, and assess cloud characteristics and aerosol concentrations. In addition, Vexcel is providing NASA with close-range photogrammetry software for the International Space Station. The technology, commercially available as FotoG(TM), was developed with SBIR funding and support from NASA's Jet Propulsion Laboratory. Commercially, FotoG is used for demanding projects taken on by engineering firms, nuclear power plants, oil refineries, and process facilities. A version of Vexcel's close-range photo measurement system was also used to create virtual 3-D backdrops for a high-tech science fiction film.

Source record↗

Lifetime fatigue response due to wake steering on a pair of utility-scale wind turbines

Quantifying the impacts on turbine loads during wind farm control is an important consideration in assessing power production benefits. Wake steering controls aim to improve total wind farm performance by coordinating the control actions of individual turbines, wherein an upstream turbine is intentionally yawed at an offset angle from the measured wind direction. Consequently, this redirects its wake for improved power production and potentially reduces fatigue loads of the downstream turbines. This paper studies the lifetime fatigue loads associated with wake steering by using utility-scale wind turbine experimental data to conduct an analysis on a pair of wind turbines. This study was part of a large field experiment in which a group of five GE 1.5-MW SLE CWE turbines were selected as targets for conducting wake steering research. A standard loads instrumentation package and data acquisition system were installed on two turbines within the cluster to measure turbine fundamental loads. The time-series databases were used to calculate loads statistics as well as short-term and lifetime damage equivalent loads. Fatigue calculations followed the guidance in Annex H of the International Electrotechnical Commission standard 61400-1, Edition 4. Lifetime fatigue calculation results are presented in this analysis; three methods of assessing lifetime fatigue were used to determine percent difference for blade root moments, main shaft moments, main shaft torque, and tower top torque. For all three fatigue treatments, some components’ lifetime fatigue increases for the controlled turbine; however, the downwind turbine experienced a reduction in lifetime fatigue and combined effect for the turbine pair results in a reduction of fatigue when wake steering controls are applied.

17 WIND ENERGY↗

Experimental system for studying temperature gradient-driven fracture of oxide nuclear fuel out of reactor

Temperature gradients in ceramic light water reactor (LWR) uranium dioxide (UO 2 ) nuclear fuel pellets generate thermal stresses that cause fractures in the fuel beginning early in the life of fresh fuel. The combination of heating due to fission and forced convective cooling on the exterior of LWR fuel rods generates a temperature profile that is difficult to replicate outside the reactor environment. In the present study, a state-of-the-art experimental set-up using electrical heating to replicate fission heating was built and surrogate fuel materials such as ceria (CeO 2 ) were used to validate the system. Cracking experiments were conducted on these surrogates by inducing reactivity-initiated-accident (RIA) like temperature gradients in the pellets via induction and direct resistance heating. Induction heating was done using copper coils and molybdenum susceptors which heated the surrogates to a threshold temperature that is sufficiently high for the fuel material to conduct current. Thereafter, direct resistance heating was used by a D.C. power supply to introduce volumetric heating to replicate LWR operating conditions analogous to fission heating. The pellets were held against nickel electrodes and mounted on a boron nitride test-stand. All the tests were carried out in a stainless-steel vacuum chamber. Simultaneous real-time dual imaging of the surrogate pellet surface has been implemented using an optical and infrared camera system which will be mounted along axial and perpendicular directions to the pellet surface respectively. A beam-splitter was used to split the incoming radiation from the sample into two halves. While one of the beams is transmitted from the splitter through a bandpass filter to obtain optical images, the other beam is reflected from the splitter to the thermal camera to capture full field temperature gradients of the as fabricated pellet surface during crack initiation and propagation. In the current series of tests, a 2-color pyrometer was used for recording and comparing the surface and centerline temperatures of the surrogate pellets in lieu of the thermal camera. A LabVIEW data acquisition system has been set up for collecting useful data during experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Degradation of Photovoltaic Modules Under High Voltage Stress in the Field: Preprint

The degradation in performance for eight photovoltaic (PV) modules stressed at high voltage (HV) is presented. Four types of modules--tandem-junction and triple-junction amorphous thin-film silicon, plus crystalline and polycrystalline silicon modules--were tested, with a pair of each biased at opposite polarities. They were deployed outdoors between 2001 and 2009 with their respective HV leakage currents through the module encapsulation continuously monitored with a data acquisition system, along with air temperature and relative humidity. For the first 5 years, all modules were biased continuously at fixed 600 VDC, day and night. In the last 2 years, the modules were step-bias stressed cyclically up and down in voltage between 10 and 600 VDC, in steps of tens to hundreds of volts. This allowed characterization of leakage current versus voltage under a large range of temperature and moisture conditions, facilitating determination of leakage paths. An analysis of the degradation is presented, along with integrated leakage charge. In HV operation: the bulk silicon modules degraded either insignificantly or at rates of 0.1%/yr higher than modules not biased at HV; for the thin-film silicon modules, the added loss rates are insignificant for one type, or 0.2%/yr-0.6%/yr larger for the other type.

14 SOLAR ENERGY↗