Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DUCTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Ducted fuel injection

Various technologies presented herein relate to enhancing mixing inside a combustion chamber to form one or more locally premixed mixtures comprising fuel and charge-gas to enable minimal, or no, generation of soot and/or other undesired emissions during ignition and subsequent combustion of the locally premixed mixtures. To enable sufficient mixing of the fuel and charge-gas, a jet of fuel can be directed to pass through a bore of a duct causing charge-gas to be drawn into the bore creating turbulence to mix the fuel and the drawn charge-gas. The duct can be located proximate to an opening in a tip of a fuel injector. The various technologies presented herein can be utilized in a number of combustion systems, such as compression-ignition (CI) reciprocating engines, spark-ignition (SI) reciprocating engines, gas-turbine (GT) engines, burners and boilers, wellhead/refinery flaring, etc.

Mueller, Charles J.↗

Bench-scale studies of in-duct mercury capture using cupric chloride-impregnated carbons

A brominated activated carbon (Darco Hg-LH) and cupric chloride-impregnated activated carbon (CuCl{sub 2}-ACs) sorbent have been tested in a bench-scale entrained-flow reactor system which was developed for simulating in-flight mercury capture in ducts upstream of particulate matter control devices. The bench-scale experimental system has been operated with the conditions of a residence time of 0.75 s and a gas temperature of 140{sup o}C to simulate typical conditions in the duct of coal-fired exhaust gas. In addition, sorbent deposition on walls which can occur in a laboratory-scale system more than in a full-scale system was significantly reduced so that additional mercury capture by the deposited sorbent was minimized. In the entrained-flow system, CuCl{sub 2}-ACs demonstrated similar performance in Hg adsorption and better performance in Hg{sup 0} oxidation than Darco Hg-LH. In addition, the carbon content of those sorbents was found to determine their Hg adsorption capability in the entrained-flow system. The bench-scale entrained-flow system was able to demonstrate the important Hg adsorption and oxidation characteristics of the tested sorbents. 18 refs., 9 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

RCUT: A Non-Invasive Method for Detection, Location, and Quantification of Radiological Contaminants in Pipes and Ducts - 12514

Radiological Characterization Using Tracers (RCUT) is a minimally invasive method for detection and location of residual radiological contamination in pipes and ducts. The RCUT technology utilizes reactive gaseous tracers that dissociate when exposed to gamma and/or beta radiation emitting from a radiological contaminant in a pipe or duct. Sulfur hexafluoride (SF{sub 6}) was selected as a tracer for this radiological application, because it is a chemically inert gas that is both nonflammable, nontoxic, and breaks down when exposed to gamma radiation. Laboratory tests demonstrated that the tracer pair of SF{sub 6} and O{sub 2} formed SO{sub 2}F{sub 2} when exposed to a gamma or beta radioactive field, which indicated the presence of radiological contamination. Field application of RCUT involves first injecting the reactive tracers into the pipe to fill the pipe being inspected and allowing sufficient time for the tracer to interact with any contaminants present. This is followed by the injection of an inert gas at one end of the pipe to push the reactive tracer at a known or constant flow velocity along the pipe and then out the exit and sampling port at the end of the pipeline where its concentration is measured by a gas chromatograph. If a radiological contaminant is present in the pipe being tested, the presence of SO{sub 2}F{sub 2} will be detected. The time of arrival of the SO{sub 2}F{sub 2} can be used to locate the contaminant. If the pipe is free of radiological contamination, no SO{sub 2}F{sub 2} will be detected. RCUT and PCUT are both effective technologies that can be used to detect contamination within pipelines without the need for mechanical or human inspection. These methods can be used to detect, locate, and/or estimate the volume of a variety of radioactive materials and hazardous chemicals such as chlorinated solvents, petroleum products, and heavy metals. While further optimization is needed for RCUT, the key first step of identification of a tracer compound appropriate for the application of detecting radioactive pipeline contamination through the detection of decomposition products of SF{sub 6} has been demonstrated. Other tracer gases that will also undergo radiolysis will be considered in the future. The next step for the RCUT development process is conducting laboratory scale tests using short pipelines to define analytical requirements, establish performance boundaries, and develop strategies for lower exposure levels. Studies to identify additional analytical techniques using equipment that is more field rugged than a GC/MS would also be beneficial. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Flow Area in the Axial Cross-Vessel Annular Duct Following a Breach of the Primary Helium Boundary of an HTGR

The lock-exchange flow phenomenon has been heavily studied for decades, including the lock-exchange phenomenon that takes place during an air ingress accident in a High-Temperature Gas-cooled Reactor (HTGR) during a break on the axial cross-vessel duct. The present study aims to characterize the gas dynamics in the cavity region of an HTGR, particularly the axial cross-vessel outer duct region. This study computes the velocity and flow area of the heavy and light currents when a break on the primary helium boundary occurs. This analysis is supported using experimental data from experiments conducted in a 1/20th length-scale HTGR. The following study summarizes the conditions of the experiment, the approach adopted to predict the flow area, and future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are (1) the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and (2) the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Duct Sealing and Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Duct Sealing and Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of flow topology on the calculation of two-phase frictional multipliers in uniformly heated flow of R-134a in a rectangular duct

The two-phase frictional multipliers for SUVA R-134a flowing in a rectangular duct (with D{sub H} = 4.8 mm) have been measured for three nominal system pressures (0.88, 1.34 and 2.34 MPa) and four nominal mass fluxes (510, 1020 and 1740, 2040 kg/m{sup 2}/s) under uniform heat flux conditions. The data is compared with adiabatic data previously taken at similar flow conditions, as well as with several classical multiplier correlations. The comparisons reveal a strong effect of pressure and mass flux on the flow topology and, by extension, a large effect on the calculation of acceleration and frictional pressure drop components. For this fluid and this geometry, entrainment and fluid separation is enhanced at higher pressures and mass flux such that most of the liquid exists in the test section edges and as dispersed droplets in the core. For these cases, the classical simplified approach to calculate acceleration pressure drop fails to adequately predict the acceleration component and leads to erroneous calculations of frictional pressure drop from the measured total pressure drop. Best estimates of the true acceleration component are given, based on void profiles measured with a gamma densitometer system, comparisons to the adiabatic data, and recasting the data in terms of the total pressure drop multiplier as a function of the Martinelli parameter, X{sub tt}. (author)

42 ENGINEERING↗

The Discrete Equation Method (DEM) for Fully Compressible, Two-Phase Flows in Ducts of Spatially Varying Cross-Section

For the simulation of light water nuclear reactor coolant flows, general two-phase models (valid for all volume fractions) have been generally used which, while allowing for velocity disequilibrium, normally force pressure equilibrium between the phases (see, for example, the numerous models of this type described in H. Städtke, Gasdynamic Aspects of Two-Phase Flow, Wiley-VCH, 2006). These equations are not hyperbolic, their physical wave dynamics are incorrect, and their solution algorithms rely on dubious truncation error induced artificial viscosity to render them numerically well posed over a portion of the computational spectrum. The inherent problems of the traditional approach to multiphase modeling, which begins with an averaged system of (ill-posed) partial differential equations (PDEs) which are then discretized to form a numerical scheme, are avoided by employing a new homogenization method known as the Discrete Equation Method (DEM) (R. Abgrall and R. Saurel, Discrete Equations for Physical and Numerical Compressible Multiphase Mixtures, J. Comp. Phys. 186, 361-396, 2003). This method results in well-posed hyperbolic systems, this property being important for transient flows. This also allows a clear treatment of non-conservative terms (terms involving interfacial variables and volume fraction gradients) permitting the solution of interface problems without conservation errors, this feature being important for the direct numerical simulation of two-phase flows. Unlike conventional methods, the averaged system of PDEs for the mixture are not used, and the DEM method directly obtains a well-posed discrete equation system from the single-phase conservation laws, producing a numerical scheme which accurately computes fluxes for arbitrary number of phases and solves non-conservative products. The method effectively uses a sequence of single phase Riemann problem solutions. Phase interactions are accounted for by Riemann solvers at each interface. Non-conservative terms are correctly approximated. Some of the closure relations missing from the traditional approach are automatically obtained. Lastly, the continuous equation system resulting from the discrete equations can be identified by taking the continuous limit with weak-wave assumptions. In this work, this approach is tested by constructing a DEM model for the flow of two compressible phases in 1-D ducts of spatially varying cross-section with explicit time integration. An analytical equation of state is included for both water vapor and liquid phases, and a realistic interphase mass transfer model is developed based on interphase heat transfer. A robust compliment of boundary conditions are developed and discussed. Though originally conceived as a first step toward implict time integration of the DEM method (to relieve time step size restrictions due to stiffness and to achieve tighter coupling of equations) in multidimensions, this model offers some unique capabilities for incorporation into next generation light water reactor safety analysis codes. We demonstrate, on a converging-diverging two-phase nozzle, that this well-posed, 2-pressure, 2-velocity DEM model can be integrated to a realistic and meaningful steady-state with both phases treated as compressible.

42 ENGINEERING↗

On the interaction between the external magnetic field and nanofluid inside a vertical square duct

In this paper, we numerically study how the external magnetic field influences the flow and thermal characteristics of nanofluid inside a vertical square duct. The flow is considered to be laminar and hydrodynamically as well as thermally developed, whereas the thermal boundary condition of constant heat flux per unit axial length with constant peripheral temperature at any cross section, is assumed. The governing equations are solved using the spectral method and the finite difference method. Excellent comparison is noted in the numerical results given by the two methods but the spectral method is found to be superior in terms of both efficiency and accuracy. We have noted that the flow reversal due to high Raleigh number may be controlled by applying an external magnetic field of suitable strength. Moreover, the Nusselt number is found to be almost a linear function of the nanoparticle volume fraction parameter, for different values of the Raleigh number and the magnetic parameter.

36 MATERIALS SCIENCE↗

Instabilities and Transition in Magnetohydrodynamic Flows in Ducts with Electrically Conducting Walls

This Letter presents a numerical study of a magnetohydrodynamic flow in a square duct with electrically conducting walls subject to a uniform, transverse magnetic field. Two regimes of instability and transition of Hunt's jets at the walls parallel to the magnetic field have been identified. The first one occurs for relatively low values of the Reynolds number Re and is associated with weak, periodic, counterrotating vortices discovered previously in linear stability studies. The second is a new regime taking place for higher values of Re. It is associated with trains of small-scale vortices enveloped into larger structures, and involves partial detachment of jets from parallel walls. Once this regime sets in, the kinetic energy of perturbations increases by 2 orders of magnitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Solid particulate mass and number from ducted fuel injection in an optically accessible diesel engine in skip-fired operation

Ducted fuel injection (DFI) is a new combustion strategy that has been shown to significantly attenuate soot formation in diesel engines. While previous studies have used optical diagnostics and optical filter smoke number methods to show that DFI reduces in-cylinder soot formation and engine-out soot emissions, respectively, this is the first study to measure solid particle number (PN) emissions in addition to particle mass (PM). Furthermore, this study quantitatively evaluates the use of transient particle instruments for measuring particles from skip-fired operation in an optical single cylinder research engine (SCRE). Engine-out PN was measured using an engine exhaust particle sizer following a catalytic stripper, and PM was measured using a photoacoustic analyzer. The study improves on earlier preliminary emissions studies by clearly showing that DFI reduces overall PM by 76%–79% and PN for particles larger than 23 nm by 77% relative to conventional diesel combustion at a 1200-rpm, 13.3-bar gross indicated mean effective pressure operating condition. The degree of engine-out PM reduction with DFI was similar across both particulate measurement instruments used in the work. Through the use of bimodal distribution fitting, DFI was also shown to reduce the geometric mean diameter of accumulation mode particles by 26%, similar to the effects of increased injection pressure in conventional diesel combustion systems. This work clearly shows the significant solid particulate matter reductions enabled by DFI while also demonstrating that engine-out PN can be accurately measured from an optical SCRE operating in a skip-fired mode. Based on these results, it is believed that DFI has the potential to enable fuel savings when implemented in multi-cylinder engines, both by lowering the required frequency of active diesel particulate filter regeneration, and by reducing the backpressure imposed by exhaust filtration systems.

33 ADVANCED PROPULSION SYSTEMS↗

Final Report: Cooling Seasonal Energy and Peak Demand Impacts of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps

A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Report: Cooling Seasonal Energy and Peak Demand Impacts of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps

A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Advanced Air Sealing, Attic Floor Insulation, and Duct Sealing and Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Advanced Air Sealing, Attic Floor Insulation, and Duct Sealing" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Advanced Air Sealing, Attic Floor Insulation, Duct Sealing and Insulation, and Drill-and-Fill Wall Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Advanced Air Sealing, Attic Floor Insulation, Duct Sealing and Insulation, and Drill-and-Fill Wall Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ducted Fuel Injection versus Conventional Diesel Combustion: An Operating-Parameter Sensitivity Study Conducted in an Optical Engine with a Four-Orifice Fuel Injector

Ducted fuel injection (DFI) has been shown to attenuate engine-out soot emissions from diesel engines. The concept is to inject fuel through a small tube within the combustion chamber to enable lower equivalence ratios at the autoignition zone, relative to conventional diesel combustion. Previous experiments have demonstrated that DFI enables significant soot attenuation relative to conventional diesel combustion for a small set of operating conditions at relatively low engine loads. This is the first study to compare DFI to conventional diesel combustion over a wide range of operating conditions and at higher loads (up to 8.5 bar gross indicated mean effective pressure) with a four-orifice fuel injector. This study compares DFI to conventional diesel combustion through sweeps of intakeoxygen mole fraction (XO 2 ), injection duration, intake pressure, start of combustion (SOC) timing, fuel-injection pressure, and intake temperature. DFI is shown to curtail engine-out soot emissions at all tested conditions. Under certain conditions, DFI can attenuate engine-out soot by over a factor of 100. In addition to producing significantly lower engine-out soot emissions, DFI enables the engine to be operated at low-NO x conditions that are not feasible with conventional diesel combustion due to high soot emissions.

42 ENGINEERING↗