Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Development and testing of a portable wind sensitive directional air sampler

A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.

Deyo, J.↗

Ultralow-Power Digital Correlator for Microwave Polarimetry

A recently developed high-speed digital correlator is especially well suited for processing readings of a passive microwave polarimeter. This circuit computes the autocorrelations of, and the cross-correlations among, data in four digital input streams representing samples of in-phase (I) and quadrature (Q) components of two intermediate-frequency (IF) signals, denoted A and B, that are generated in heterodyne reception of two microwave signals. The IF signals arriving at the correlator input terminals have been digitized to three levels (-1,0,1) at a sampling rate up to 500 MHz. Two bits (representing sign and magnitude) are needed to represent the instantaneous datum in each input channel; hence, eight bits are needed to represent the four input signals during any given cycle of the sampling clock. The accumulation (integration) time for the correlation is programmable in increments of 2(exp 8) cycles of the sampling clock, up to a maximum of 2(exp 24) cycles. The basic functionality of the correlator is embodied in 16 correlation slices, each of which contains identical logic circuits and counters (see figure). The first stage of each correlation slice is a logic gate that computes one of the desired correlations (for example, the autocorrelation of the I component of A or the negative of the cross-correlation of the I component of A and the Q component of B). The sampling of the output of the logic gate output is controlled by the sampling-clock signal, and an 8-bit counter increments in every clock cycle when the logic gate generates output. The most significant bit of the 8-bit counter is sampled by a 16-bit counter with a clock signal at 2(exp 8) the frequency of the sampling clock. The 16-bit counter is incremented every time the 8-bit counter rolls over.

Piepmeier, Jeffrey R.↗

In Situ Chemical Reduction Interim Measures Work Plan Hot Spot 3 Mobile Launcher Platform Rehabilitation Sites / Vehicle Assembly Building Area (SWMU 056) Kennedy Space Center, Florida

This document presents the design details of an In Situ Chemical Reduction (ISCR) Interim Measures Work Plan for Hot Spot 3 within Mobile Launcher Platform Rehabilitation Sites/Vehicle Assembly Building Area, Solid Waste Management Unit (SWMU) 056 (SWMU 056), located at the John F. Kennedy Space Center, Florida. The interim measures (IM) treatment zone encompasses an area identified as the High Concentration Plume (HCP), which is defined as the area with chlorinated volatile organic compound (CVOC) groundwater concentrations greater than their respective Natural Attenuation Default Concentration (NADC). The objective of the IM is to remove CVOC mass within the treatment area to levels that facilitate a transition to natural attenuation monitoring. The IM design consists of the selected ISCR amendment, Provect-IR, which is a mixture of solid reagents in a single product that promotes enhanced reductive dechlorination and ISCR. ProvectIR includes natural antimethanogenic compounds; multiple hydrophilic, nutrient-rich organic carbon sources; zero valent iron; chemical oxygen scavengers; and vitamin and mineral sources. The proposed treatment area for this IM encompasses less than 1 acre and includes three vertical treatment intervals to reach the NADC plumes that vary per CVOC and depth: 4 to 10 feet below land surface (bls), 10 to 18 feet bls, and 42 to 52 feet bls. The amendment will be distributed through 16 injection points (IP01 through IP16) using dosing rates ranging from 0.4% to 0.6% of soil mass within the treatment interval and a 15% or 20% slurry strength. Dosage rates and slurry strength are based on groundwater geochemistry, soil characteristics, and contaminant concentrations. To aid in the evaluation of the ISCR IM performance, six performance monitoring wells will be installed following injections and sampled semiannually. CVOC parameters will be sampled until concentrations reduce to below their NADC. Underground Injection Control parameters will be sampled until concentrations decrease to background levels or to levels that meet respective groundwater standards. Sampling frequency will be evaluated annually and modified as needed. The path forward for the ISCR IM implementation includes preparing the IM Implementation Work Plan, ISCR injections, monitoring well installation, performance monitoring, and reporting.

Randall K. Sillan↗

Continuous Fiberization of Silicon-Carbide-Nitride Precursor Resin

The objective of this project is to design and build a laboratory scale extruder and with it to fiberize 5000 continuous feet of silicon-carbide-nitride precursor resin. Subsequently the objective is extended to include the cross-linking and pyrolysis of approximately 100 feet of the resin fiber. The extruder is designed to accommodate approximately 1 cubic centimeter samples at accurately controllable rates corresponding to take-up from a single orifice of a 25 micron fiber at speeds in the 1000 feet/minute region. Positive feed delivery is achieved with a cylinder and piston driven by a geared down electric motor. Gear reduction is achieved primarily with off-the-shelf parts. Over 5000 feet of fiber, 20 to 30 micron diameter, are spun from precursor resin samples. The formation of continuous silicon carbide/silicon nitride fiber appears to be feasible.

Dunn, S. A.↗

Controllable Skyrmionic Phase Transition between Néel Skyrmions and Bloch Skyrmionic Bubbles in van der Waals Ferromagnet Fe 3-δ GeTe 2

The van der Waals (vdW) ferromagnet Fe 3-δ GeTe 2 has garnered significant research interest as a platform for skyrmionic spin configurations, that is, skyrmions and skyrmionic bubbles. However, despite extensive efforts, the origin of the Dzyaloshinskii–Moriya interaction (DMI) in Fe 3-δ GeTe 2 remains elusive, making it challenging to acquire these skyrmionic phases in a controlled manner. In this study, it is demonstrated that the Fe content in Fe 3-δ GeTe 2 has a profound effect on the crystal structure, DMI, and skyrmionic phase. For the first time, a marked increase in Fe atom displacement with decreasing Fe content is observed, transforming the original centrosymmetric crystal structure into a non-centrosymmetric symmetry, leading to a considerable DMI. Additionally, by varying the Fe content and sample thickness, a controllable transition between Néel-type skyrmions and Bloch-type skyrmionic bubbles is achieved, governed by a delicate interplay between dipole–dipole interaction and the DMI. The findings offer novel insights into the variable skyrmionic phases in Fe 3-δ GeTe 2 and provide the impetus for developing vdW ferromagnet-based spintronic devices.

2D ferromagnet Fe3-δGeTe2↗

Contamination Observed on the Passive Optical Sample Assembly (POSA)-1 Experiment

The Passive Optical Sample Assembly-1 (POSA-1), part of the Mir Environmental Effects Payload (MEEP), was designed to study the combined effects of contamination, atomic oxygen, ultraviolet radiation, vacuum, thermal cycling, and other constituents of the space environment on spacecraft materials. The MEEP program is a Phase 1 International Space Station Risk Mitigation Experiment. The payload was attached by EVA to the exterior of the Mir docking module during the Space Shuttle mission STS-76. It was removed during STS-86 after exposure to the Mir environment for 18 months. POSA-1 consists of nearly 400 samples of thermal control paints, chemical conversion coatings, mirrors, optics, and other candidate materials for International Space Station Alpha (ISSA). POSA-1 also flew state-of-the-art materials, such as electrically conductive thermal control coatings developed under contract by IITRI and AZ Technology, and passive instruments for monitoring the atomic oxygen and ultraviolet radiation dose to the experiment. Contamination was detected on the POSA-1 experiment. On the side facing space (-Z(sub B) direction using the Mir coordinate system), visible contamination was observed. The contamination was uniform as would occur from a slow photodeposition process. A very definite film was deposited on the optical samples. The deposition appears to have directionality with definite shadowing effects. On the side facing the main Mr core (+ZB direction using the Mir coordinate system), no visible contamination was noted. Pre- and post-flight characterization of candidate spacecraft materials is discussed, particularly the effect of contamination on total hemispherical spectral reflectance (250 - 2500 nm), infrared emittance, the bi-directional reflectance distribution function (BRDF), and vacuum ultraviolet spectral reflectance. Extensive photography under normal and black light was performed. Results of electron spectroscopy for chemical analysis (ESCA) and Fourier Transform Infrared Analysis (FTIR) on selected samples are also discussed.

Zwiener, James M.↗

Distributed I/O Control System Implementation for the 1238 Optical Witness Sample Thermoelectric Quartz Crystal Microbalance Thermal Vacuum Bakeout Chamber

The 1238 Thermal Vacuum Bakeout Chamber is used to test materials to determine if they meet space program contamination requirements. The system was previously manual in its operation, in that there was no supervisory control system and therefore, no means for automated operation. Marshall Space Flight Center (MSFC) requested that its operation be automated. The subsequent process implemented involved a hybrid scenario that included existing hardware, a distributed input and output (I/O) system and a graphical user interface (GUI).

Randy K. Buchanan↗

Minimizing Segregation During the Controlled Directional Solidification of Dendritic Alloys Publication: Metallurgical and Materials Transactions

Gravity-driven thermosolutal convection that arises during controlled directional solidification (DS) of dendritic alloys promotes detrimental macro-segregation (e.g. freckles and steepling) in products such as turbine blades. Considerable time and effort has been spent to experimentally and theoretically investigate this phenomena; although our knowledge has advanced to the point where convection can be modeled and accurately compared to experimental results, little has been done to minimize its onset and deleterious effects. The experimental work demonstrates that segregation can be. minimized and microstructural uniformity promoted when a slow axial rotation is applied to the sample crucible during controlled directional solidification processing. Numerical modeling utilizing continuation and bifurcation methods have been employed to develop accurate physical and mathematical models with the intent of identifying and optimizing processing parameters.

Grugel, R. N.↗

AERACEPT (AErosol Rapid Analysis Combined Entry Probe/sonde Technology) for the Nephele Venus Cloud Mission Concept

Nephele is a small atmospheric probe mission concept to determine whether the Venus clouds contain organic matter. Nephele complements larger missions that seek to conduct Venus atmospheric analyses, such as DAVINCI, Venera-D, and the Morning Star missions, by directly sampling and analyzing cloud and haze particles. AERACEPT is an aerosol sampling technology designed to minimize the mass, volume, and complexity required for in situ planetary atmosphere characterization. A single aeroshell functions as a combined entry vehicle, descent probe, and instrumented sonde, combining recent advances in thermal protection materials with heritage technology from planetary and airborne science. The velocity of descent drives aerosol through inlets embedded in the aeroshell’s thermal protection material; inertial separation isolates the particles from the gas stream; and the particle capture surface doubles as the analysis substrate. This method can work without heat shield separation, descent control, or active sample handling; these advantages trade against a smaller sample volume, higher risk of sample heating, and shorter time for analysis and data return. AERACEPT further benefits from modeling of the internal and external flow to understand the particle capture efficiency and bias for size and concentration distributions. AERACEPT is well suited for a Venus mission such as Nephele, where a passive descent trajectory is both subsonic over the altitudes of interest and provides sufficient velocity and pressure differential for the particle sizes of interest. A thermal and flow toolchain developed in-house (Traj→ DPLR→ PATO→ openFOAM) was used to model an 80-cm aeroshell with science operations 63–39 km. These models indicate that AERACEPT will provide ~24 µL accumulated sample of particles ≥ 0.2 µm, substantially above the 2 µL threshold requirement. The worst-case particle heating will be ~14 K above ambient, for the smallest particles at the lowest altitude; most particles will experience ≤ 1 K rise, at which almost all analytes of interest will be unaffected. Plasma jet testing of a small-scale aeroshell-material inlet was recently conducted to validate the thermal model parameters; wind tunnel testing to validate the flow model parameters is underway.

AERACEPT↗

Microstructural transitions during containerless processing of undercooled Fe-Ni alloys

In order to identify the possible hierarchy of microstructural pathways and transitions, a systematic evaluation of the microstructural evolution in undercooled Fe-Ni alloys was performed on uniformly processed samples covering seven orders of magnitude in volume. At appropriate undercooling levels, alternate solidification pathways become thermodynamically possible and metastable product structures can result from the operation of competitive solidification kinetics. For thermal history evaluation, a heat flow analysis was applied and tested with large Fe-Ni alloy particles (1 to 3 mm) to assess undercooling potential. Alloy powders (10 to 150 microns), with large liquid undercoolings, were studied under the same composition and processing conditions to evaluate the solidification kinetics and microstructural evolution, including fcc/bcc phase selection and the thermal stability of a retained metastable bcc phase. The identification of microstructural transitions with controlled variations in sample size and composition during containerless solidification processing was used to develop a microstructure map which delineates regimes of structural evolutions and provides a unified analysis of experimental observations in the Fe-Ni system.

Thoma, D. J.↗

Spacelab Charcoal Analyses

This report describes analytical methods and results obtained from chemical analysis of 31 charcoal samples in five sets. Each set was obtained from a single scrubber used to filter ambient air on board a Spacelab mission. Analysis of the charcoal samples was conducted by thermal desorption followed by gas chromatography/mass spectrometry (GC/MS). All samples were analyzed using identical methods. The method used for these analyses was able to detect compounds independent of their polarity or volatility. In addition to the charcoal samples, analyses of three Environmental Control and Life Support System (ECLSS) water samples were conducted specifically for trimethylamine.

Slivon, L. E.↗

PCR Based Microbial Monitor for Analysis of Recycled Water Aboard the ISSA: Issues and Prospects

The monitoring of spacecraft life support systems for the presence of health threatening microorganisms is paramount for crew well being and successful completion of missions. Development of technology to monitor spacecraft recycled water based on detection and identification of the genetic material of contaminating microorganisms and viruses would be a substantial improvement over current NASA plans to monitor recycled water samples that call for the use of conventional microbiology techniques which are slow, insensitive, and labor intensive. The union of the molecular biology techniques of DNA probe hybridization and polymerase chain reaction (PCR) offers a powerful method for the detection, identification, and quantification of microorganisms and viruses. This technology is theoretically capable of assaying samples in as little as two hours with specificity and sensitivity unmatched by any other method. A major advance in probe-hybridization/PCR has come about in a technology called TaqMan(TM), which was invented by Perkin Elmer. Instrumentation using TaqMan concepts is evolving towards devices that could meet NASA's needs of size, low power use, and simplicity of operation. The chemistry and molecular biology needed to utilize these probe-hybridization/PCR instruments must evolve in parallel with the hardware. The following issues of chemistry and biology must be addressed in developing a monitor: Early in the development of a PCR-based microbial monitor it will be necessary to decide how many and which organisms does the system need the capacity to detect. We propose a set of 17 different tests that would detect groups of bacteria and fungus, as well as specific eukaryotic parasites and viruses; In order to use the great sensitivity of PCR it will be necessary to concentrate water samples using filtration. If a lower limit of detection of 1 microorganism per 100 ml is required then the microbes in a 100 ml sample must be concentrated into a volume that can be added to a PCR assay; There are not likely to be contaminants in ISSA recycled water that would inhibit PCR resulting in false-negative results; The TaqMan PCR product detection system is the most promising method for developing a rapid, highly automated gene-based microbial monitoring system. The method is inherently quantitative. NASA and other government agencies have invested in other technologies that, although potentially could lead to revolutionary advances, are not likely to mature in the next 5 years into working systems; PCR-based methods cannot distinguish between DNA or RNA of a viable microorganism and that of a non-viable organism. This may or may not be an important issue with reclaimed water on the ISSA. The recycling system probably damages the capacity of the genetic material of any bacteria or viruses killed during processing to serve as a template in a PCR desinged to amplify a large segment of DNA (less than 650 base pairs). If necessary, vital dye staining could be used in addition to PCR, to enumerate the viable cells in a water sample; The quality control methods have been developed to insure that PCR's are working properly, and that reactions are not contaminated with PCR carryover products which could lead to the generation of false-positive results; and The sequences of the small rRNA subunit gene for a large number of microorganisms are known, and they consititue the best database for rational development of the oligonucleotide reagents that give PCR its great specificity. From those gene sequences, sets of oligonucleotide primers for PCR and Taqman detection that could be used in a NASA microbial monitor were constructed using computer based methods. In addition to space utilization, a microbial monitior will have tremendous terrestrial applications. Analysis of patient samples for microbial pathogens, testing industrial effluent for biofouling bacteria, and detection biological warfare agents on the battlefield are but a few of the diverse potential uses for this technology. Once fully developed, gene-based microbial monitors will become the fundamental tool in every lab that tests for microbial contaminants, and serve as a powerful weapon in mankind's war with the germ world.

Cassell, Gail H.↗

Modification of the continuous flow diffusion chamber for use in zero-gravity

The design philosophy and performance characteristics of the continuous flow diffusion chamber developed for use in ground-based simulation of some of the experiments planned for the atmospheric cloud physics laboratory during the first Spacelab flight are discussed. Topics covered include principle of operation, thermal control, temperature measurement, tem-powered heat exchangers, wettable metal surfaces, sample injection system, and control electronics.

Keyser, G.↗

Emperical Tests of Acceptance Sampling Plans

Acceptance sampling is a quality control procedure applied as an alternative to 100% inspection. A random sample of items is drawn from a lot to determine the fraction of items which have a required quality characteristic. Both the number of items to be inspected and the criterion for determining conformance of the lot to the requirement are given by an appropriate sampling plan with specified risks of Type I and Type II sampling errors. In this paper, we present the results of empirical tests of the accuracy of selected sampling plans reported in the literature. These plans are for measureable quality characteristics which are known have either binomial, exponential, normal, gamma, Weibull, inverse Gaussian, or Poisson distributions. In the main, results support the accepted wisdom that variables acceptance plans are superior to attributes (binomial) acceptance plans, in the sense that these provide comparable protection against risks at reduced sampling cost. For the Gaussian and Weibull plans, however, there are ranges of the shape parameters for which the required sample sizes are in fact larger than the corresponding attributes plans, dramatically so for instances of large skew. Tests further confirm that the published inverse-Gaussian (IG) plan is flawed, as reported by White and Johnson (2011).

White, K. Preston, Jr.↗

Helium mining on the Moon: Site selection and evaluation

The feasibility of recovering helium (He) from the Moon as a source of fusion energy on Earth is currently being studied at the University of Wisconsin. Part of this study is selection and evaluation of potential sites for lunar He mining. Selection and evaluation of potential mining sites are based on four salient findings by various investigators of lunar samples: (1) Regoliths from areas underlain by highland materials contain less than 20 wppm He; (2) Certain maria regoliths contain less than 20 wppm He, but other contain 25 to 49 wppm; (3) The He content of a mare regolith is a function of its composition; regoliths rich in Ti are relatively rich in He; and (4) He is concentrated in the less than 100-micron size fractions of regoliths. The first three findings suggest that maria are the most promising mining sites, specifically, those that have high-Ti regoliths. Information on the regional distribution and extent of high-Ti regoliths comes mainly from two sources: direct sampling by various Apollo and Luna missions, and remote sensing by gamma-ray spectroscopy and Earth-based measurements of lunar spectral reflectance. Sampling provides essential control on calibration and interpretation of data from remote sensing. These data indicate that Mare Tranquillitatis is the principal area of high-Ti regolith of the eastern nearside, but large areas of high-Ti regolith are indicated in the Imbrium and Procellarum regions. Recovery of significant amounts of He-3 will require mining billions of tonnes of regolith. Large individual areas suitable for mining must therefore be delineated. The concentration of He in the finer size fractions and considerations of ease of mining mean that mining areas must be as free as possible of sizable craters and blocks of rock. Pending additional lunar missions, information regarding these features must be obtained from lunar photographs, photogeologic maps, and radar surveys. The present study is decidedly preliminary; available information is much to limited to permit even a close approach to final evaluations. As a prelude to recovery of He from the Moon, systematic exploration and sampling of high-Ti regoliths should therefore have a high priority in future lunar missions.

Cameron, Eugene N.↗

Thermal Control Materials on MISSE-6 with Comparison to Earlier Flight Data

This slide presentation reviews the results of exposing thermal control materials as studied during Materials International Space Station Experiment-6 (MISSE-6). It discusses the location of the materials, and the type of environmental exposure. It then reviews the effect on the various types of coatings, showing the results with graphs and photos of the samples after the experimental exposure to the low earth orbital environment for comparison with the control sample and with earlier flights.

Finckenor, Miria M.↗

XPS guide: Charge neutralization and binding energy referencing for insulating samples

This guide deals with methods to control surface charging during XPS analysis of insulating samples and approaches to extracting useful binding energy information. Furthermore, the guide summarizes the causes of surface charging, how to recognize when it occurs, approaches to minimize charge buildup, and methods used to adjust or correct XPS photoelectron binding energies when charge control systems are used. Additionally, there are multiple ways to control surface charge buildup during XPS measurements and examples of systems on advanced XPS instruments are described. There is no single, simple, and foolproof way to extract binding energies on insulating material, but advantages and limitations of several approaches are described. Because of the variety of approaches and limitations of each it is critical for researchers to accurately describe the procedures that have been applied in research reports and publications.

47 OTHER INSTRUMENTATION↗