Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous byproducts of laboratory research activities or airborne pathogens. As a result, building ventilation is a primary defense against unseen airborne hazards. Critical laboratory facilities require effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an in-depth intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently many contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in critical laboratory environments. In this article, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories. This article describes a low-cost sensor to support providing a safe, healthy building environment and reduce energy use through effective and efficient ventilation.

dynamic management of indoor air quality↗

Techno Economic Analysis for Production of Renewable Natural Gas and Value-Added Chemicals from Forest Biomass Residues (CRADA Final Report)

West Biofuels - in collaboration with the University of California San Diego, the University of California Davis, the National Laboratory of the Rockies (NLR), the Colorado School of Mines’ Center for Hydrate Research, Placer County Air Pollution Control District, the Sierra Business Council, and the Southern California Gas Company (SoCalGas)-will demonstrate an innovative pathway to convert forest biomass to renewable gas (RG). The project, Production of Pipeline Grade Renewable Natural Gas and Value-Added Chemicals from Forest Biomass Residues, will utilize an existing pilot-scale gasification system and data and lessons learned from a lab-scale catalytic reactor design, develop, and demonstrate an integrated pilot-scale RG process with a scaled-up catalytic reactor and hydrate-based gas separation process. This robust and simple process uses a commercial proven gasifier, a commercially available catalyst that can tolerate gas contaminants, and a gas separation process that simplifies the downstream processing. Current testing has shown that the process can yield a large amount of methane rich renewable gas in addition to a mixture of propanol, ethanol and other higher alcohols and the relative amounts can be controlled by shifting the process conditions. This process is novel and groundbreaking because the product mixture of RG and valuable alcohols byproducts makes RG production economically feasible at $\$$12 per million British thermal units (MMBtu) or less using forest biomass from high hazard zones.

09 BIOMASS FUELS↗

Silicate coating to prevent leaching from radiolabeled surrogate far-field fallout in aqueous environments

Recent characterization of radioactive particles indicate that a large percentage of the radioactivity observed during the Fukushima Daiichi nuclear meltdown was insoluble 137 Cs bound within silica microparticles. Therefore, much of the decontamination research performed prior to the Fukushima incident that used either soluble radionuclides deposited onto wet surfaces or large (~100 μm) particles characteristic of nuclear weapons fallout do not accurately represent the characteristics of potential contamination. Thus, the common practice of extrapolating radioactive decontamination methods generically to all radioactive release events is, at best, suspect. In response, a method to produce chemically-inert, radiolabeled silica particles was developed. Binding 152 Eu within a sodium silicate coating required proper temperature control and ethanol was beneficial as a volatile dispersant to limit residues. In the end, a step-wise method, which first deposited 152 Eu or 241 Am as a nitrate salt, decomposed the salt to a sesquioxide, and finally coated the surface with sodium silicate led to dispersed particles of the desired 2 or 0.5 μm diameters. Dynamic light scattering and scanning election microscopy confirmed the particle size was unchanged. Leaching studies into several common decontaminants were performed to ensure particle inertness. In this paper, our approach allows for substitution of other radionuclides making it a robust, simple, and novel method to produce inert particle surrogates for a release event that allows direct comparison of decontamination techniques and contaminant fate studies, greatly aiding the development of response and recovery plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Millisecond lifetimes and coherence times in 2D transmon qubits

Materials improvement is a powerful approach to reducing loss and decoherence in superconducting qubits, because such improvements can be readily translated to large-scale processors. Recent work improved transmon coherence by using tantalum as a base layer and sapphire as a substrate. The losses in these devices are dominated by two-level systems with comparable contributions from both the surface and bulk dielectrics, indicating that both must be tackled to achieve substantial improvements in the state of the art. Here we show that replacing the substrate with high-resistivity silicon markedly decreases the bulk substrate loss, enabling 2D transmons with time-averaged quality factors (Q avg ) of 9.7 × 10 6 across 45 qubits. For our best qubit, we achieve a Q avg of 1.5 × 10 7 , reaching a maximum Q of 2.5 × 10 7 , corresponding to a lifetime (T 1 ) up to 1.68 ms. This low loss also allows us to observe decoherence effects related to the Josephson junction, and we use an improved, low-contamination junction deposition to achieve Hahn echo coherence times (T 2E ) exceeding T 1 . We achieve these materials improvements without any modifications to the qubit architecture, allowing us to readily incorporate standard quantum control gates. Here, we demonstrate single-qubit gates with 99.994% fidelity. The tantalum-on-silicon platform comprises a simple material stack that can potentially be fabricated at the wafer scale and therefore can be readily translated to large-scale quantum processors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Solid electrolytes for solid-state and lithium-sulfur batteries

The stringent demands placed on batteries by emerging vehicle technologies such as plug-in and battery electric vehicles suggest that improvements in the safety and performance of electrochemical energy storage devices, as well as concurrent reductions in their cost, are highly desirable. Current strategies for improving performance have largely focused on Li-ion battery chemistries. In this project went beyond the state of the art by pursuing electrolyte chemistries that will enable the use of Li metal anodes and sulfur cathodes, either concurrently in a solid state Li-S battery, or as a means to achieve a Li metal anode which is stable upon cycling. More specifically, our effort advanced strategies to enable Li metal anodes for myriad beyond Li-ion chemistries . LLZO garnet (Li 7 La 3 Zr 2 O 12 ) is the first bulk-scale ceramic electrolyte to exhibit the combination of superionic conductivity (1mS/cm at 298K), high shear modulus (61 GPa) to suppress Li dendrite penetration, and apparent electrochemical stability (0-6V vs Li/Li + ), thus enabling Li metal anodes. However, to date there are no reports confirming LLZO can tolerate current densities > 1mA/cm 2 , thus demonstrating relevance to PHEV/EV batteries. Our goal was to investigate the mechanisms that govern the Li-LLZO interfacial stability as a function of current density. We determined that defects in polycrystalline LLZO reduce the critical current density (CCD). Primarily contaminants on the LLZO surface and grain boundaries were the primary defects the limited the CCD. Using our experience with synthesis and processing (Sakamoto and Wolfenstine) and sophisticated materials characterization (Nanda), we precisely controlled atomistic and microstructural defects and correlated their effects on controlling the critical current density. These data fed into multi-scale computation models (Siegel and Monroe) to isolate and quantify the roles that each defect played in controlling the critical current density. Bridging this knowledge gap allowed us to demonstrate that LLZO can withstand > 1mA/cm 2 .

25 ENERGY STORAGE↗

Site Environmental Report for 2017

Lawrence Berkeley National Laboratory (LBNL, Berkeley Lab) is a multi-program scientific facility operated by the University of California (UC) for the U.S. Department of Energy (DOE). Berkeley Lab’s research is focused on the physical, biological, environmental, and computational sciences with the objective of delivering scientific knowledge and discoveries pertinent to DOE’s mission. This annual report describes environmental protection activities and potential impacts resulting from LBNL operations conducted in 2017. The format and content of this report satisfy the requirements of both DOE Order 231.1B, Administrative Change 1 (Environment, Safety, and Health Reporting) and the operating contract between UC and DOE (DOE Contract No. DE-AC02-05CH11231, also known as Contract 31). Activities are planned and conducted with full regard to protecting employees, the public, and the environment, as well as complying with all applicable environmental, safety, and health laws and regulations. Berkeley Lab implements an Environmental Management System (EMS) to oversee these compliance activities and continually improve overall environmental performance while maintaining operational capability and sustaining its overall mission. The effectiveness of the EMS and environmental programs is reviewed annually as part of the performance evaluation process of Contract 31. For fiscal year (FY) 2017, which began October 1, 2016, and ended September 30, 2017, the EMS was given a performance rating of B plus for its management of environmental activities (on a scale from A plus as the highest grade to F as the lowest). The measurement and rating system was developed jointly by Berkeley Lab, UC, and DOE. The FY 2017 rating was based on how Berkeley Lab met the objective in DOE’s FY 2017 Performance Evaluation and Measurement Plan (Appendix B in Contract 31, Section J) of providing an efficient and effective EMS. Six significant accomplishments, which ranged from effective teaming on projects and with regulatory agencies to improved program assessment approaches, were factors in the rating. The EMS was also graded through the federal Office of Management and Budget’s annual EMS performance metrics, in which a reporting scorecard rates elements of the International Organization for Standardization (ISO) 14001 standard and the degree of integration between the EMS and Berkeley Lab’s sustainable practices. Overall scores fall into one of three categories: green (highest), yellow (middle), or red (lowest). For FY 2017, Berkeley Lab received a score of green, as described in more detail in Chapter 2. An overview of environmental protection and restoration programs is provided, including information about compliance activities, operating permits, and regulatory agency inspections that occurred during 2017. Thirteen minor violations issued during City of Berkeley inspections of above and underground storage tanks, treatment units, and hazardous waste storage areas are discussed in this chapter. This report also includes information on environmental monitoring performed in 2017. The results of these monitoring activities confirmed that groundwater cleanup actions continue to show improving conditions, and all emissions and discharges from LBNL operations were within environmental compliance release limits, with the exception of some stormwater discharges. Most stormwater discharges measured throughout the LBNL site fall within acceptable levels established by the state’s stormwater permit; however, iron and aluminum exceeded Numeric Action Levels. To reduce iron and aluminum discharge levels, Berkeley Lab is aggressively implementing controls such as construction of asphaltic berms and check dams to restrain and filter runoff to storm drains, and installation of filtration units in storm drain basins to collect sediment and absorb metal contaminants. The radiological dose assessments performed in 2017 concluded that the maximum potential dose to a hypothetical resident from Berkeley Lab’s airborne radionuclide releases was approximately 0.1% of the DOE and U.S. Environmental Protection Agency annual limit of 10 millirem per year (mrem/yr); the potential dose from all radiation sources at Berkeley Lab was approximately 0.06% of the average natural background radiation dose of 310 mrem/yr in the United States, and about 0.2% of the DOE annual limit of 100 mrem/yr from all sources.

54 ENVIRONMENTAL SCIENCES↗

FX Hg Fogging Fixative Deployment for Mercury Vapor Suppression

Idaho National Laboratory’s (INL) FX Hg fixative solution was deployed at the Y-12 Complex in Oak Ridge, Tennessee to support disposal of mercury-contaminated metal debris. The fixative was dispensed via fogging. Fogging infiltrates non-line-of-sight areas improving fixative coating on complex geometries such as debris piles. FX Hg is the mercury vapor controlling derivative of INL’s FX2 fixative. FX2 was jointly developed with the National Nuclear Laboratory of the United Kingdom, and INL developed the FX Hg derivative to suppress mercury vapor generation. The Y-12 deployment was performed in concert with cleanup contractor UCOR. A dumpster filled with debris was fogged with FX Hg. The material was acceptable as municipal landfill waste, save for the mercury vapor levels measured. If the mercury vapor generation rate could be sufficiently reduced, disposal costs for this waste would be dramatically reduced. FX Hg had previously proven effective at significantly reducing mercury vapor generation rates in bench scale testing at INL. This deployment was the first field scale deployment of the method. Efficacy results were underwhelming, but interpretation of the outcome is complicated by a paucity of hard data. Methods for improving data capture and analysis are analyzed. Operational difficulties associated with scaling the process up and process improvements for future deployments are discussed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FX Hg Fogging Fixative Deployment for Mercury Vapor Suppression - 20410

Idaho National Laboratory's (INL) FX Hg fixative solution was deployed at the Y-12 National Security Complex in Oak Ridge, Tennessee to support disposal of mercury-contaminated metal debris. The fixative was dispensed via fogging. Fogging infiltrates non-line-of-sight areas improving fixative coating on complex geometries such as debris piles. FX Hg is the mercury vapor controlling derivative of INL's FX2 fixative. FX2 was jointly developed with the National Nuclear Laboratory of the United Kingdom, and INL developed the FX Hg derivative to suppress mercury vapor generation. The Y-12 deployment was performed in concert with UCOR (URS CH2M Oak Ridge), the cleanup contractor for Y-12. A dumpster filled with debris was fogged with FX Hg. The debris was acceptable as municipal landfill waste, save for the mercury vapor levels measured. If the mercury vapor generation rate could be sufficiently reduced, disposal costs for this waste would be dramatically reduced. FX Hg had previously proven effective at significantly reducing mercury vapor generation rates in bench scale testing at INL. This deployment was the first field-scale deployment of the method. Efficacy results were underwhelming, but interpretation of the outcome is complicated by a paucity of hard data. Methods for improving data capture and analysis are analyzed. Operational difficulties associated with scaling up the process and process improvements for future deployments are discussed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multi-Sensor Optimal Motion Planning for Radiological Contamination Surveys by Using Prediction-Difference Maps

Distributed and networked mobile sensor platforms using unmanned aerial and/or ground vehicles to survey areas of interest offer a safer and more efficient method for radiological contamination mapping; however, most applications rely on uniformly sweeping of the area in a raster-type motion without utilizing the information available in a dynamic sense. We have developed a fully autonomous optimal motion planning procedure for networks with two or more mobile sensors. The procedure utilizes well-established concepts of Gaussian processes in combination with control laws based on centroidal Voronoi tessellations to achieve optimal next-iteration sensor movements. A new method of informing optimal motion planning is proposed, whereby the absolute difference between the prior and current full-map prediction, referred to as the prediction-difference map, is used as the spatial density function within each Voronoi cell, providing immediate and iterative feedback for dynamic use of available information. The Gaussian process regression model used to estimate the contamination in unvisited locations also provides prediction uncertainties, and can be used as a quantitative metric to assess the confidence in the calculated contamination map; these estimates and prediction uncertainties are unavailable for standard uniform survey routines as they can only produce maps in the vicinity of observed locations. We present through simulation the achievable performance gains from using this new method by directly comparing to a uniform survey method. Results show that using the prediction-difference maps to inform motion planning procedures offers a faster rate of producing an accurate and convergent map relative to a uniform survey route.

47 OTHER INSTRUMENTATION↗

Determination of water saturation using gas phase partitioning tracers and time-lapse electrical conductivity measurements

Water saturation is an important indicator of contaminant distribution and plays a governing role in contaminant transport within the vadose zone. Understanding the water saturation distribution is critical for both remediation and contaminant flux monitoring in unsaturated environments. In this work we propose and demonstrate a method of remotely determining water saturation levels using gas phase partitioning tracers and time-lapse bulk electrical conductivity measurements. The theoretical development includes the partitioning chemistry for the tracers we demonstrate (ammonia and carbon dioxide), as well as a review of the petrophysical relationship governing how these tracers influence bulk conductivity. We also investigate methods of utilizing secondary information provided by electrical conductivity breakthrough magnitudes induced by the tracers. We test the method on clean, well characterized, intermediate-scale sand columns under controlled conditions. Results demonstrate the capability to predict partitioning coefficients and accurately monitor gas breakthrough curves along the length of the column according to the corresponding electrical conductivity response, leading to accurate water saturation estimates. This work is motivated by the need to develop effective characterization and monitoring techniques for contaminated deep vadose zone environments, and provides a proof-of-concept toward uniquely characterizing and monitoring water saturation levels at the field scale and in three-dimensions using electrical resistivity tomography.

30 DIRECT ENERGY CONVERSION↗

Evaluation of fuel-borne sodium effects on a DOC-DPF-SCR heavy-duty engine emission control system: Simulation of full-useful life

Here we report that for renewable fuels to displace petroleum, they must be compatible with emissions control devices. Pure biodiesel contains up to 5 ppm Na + K and 5 ppm Ca + Mg metals, which have the potential to degrade diesel emissions control systems. This study aims to address these concerns, identify deactivation mechanisms, and determine if a lower limit is needed. Accelerated aging of a production exhaust system was conducted on an engine test stand over 1001 h using 20% biodiesel blended into ultra-low sulfur diesel (B20) doped with 14 ppm Na. This Na level is equivalent to exposure to Na at the uppermost expected B100 value in a B20 blend for the system full-useful life. During the study, NOx emissions exceeded the engine certification limit of 0.33 g/bhp-hr before the 435,000-mile requirement. Replacing aged diesel oxidation catalyst (DOC), diesel particulate filter (DPF), and selective catalytic reduction (SCR) devices with new degreened parts showed that each device contributed equally to the NOx increase. Following this systems-based evaluation, a detailed investigation of the individual components was completed. Na was determined to have minimal impact on DOC activity. For this system, it is estimated that B20-Na resulted in 50% more ash into the DPF. However, the Na did not diffuse into the cordierite DPF nor degrade its mechanical properties. The SCR degradation was found to be caused by a small amount of precious group metals (PGM) contamination that increased NH3 oxidation, and lowered NOx reduction. Therefore, we determined that the primary effect of Na in this study is through increased ash in the DPF rather than deactivation of the catalytic activity.

42 ENGINEERING↗

Progress toward Biomass and Coal-Derived Syngas Warm Cleanup: Proof-of-Concept Process Demonstration of Multicontaminant Removal for Biomass Application

Systems comprising of multiple sorbent and catalytic beds have been developed for the warm syngas cleanup of coal- and biomass-derived syngas. Tailored specifically for biomass application the process described here consists of six primary unit operations: 1) Na2CO3 bed for HCl removal, 2) two regenerable ZnO beds for bulk H2S removal, 3) ZnO bed for H2S polishing, 4) NiCu/SBA-16 sorbent for trace metal (e.g. AsH3) removal, 5) steam reforming catalyst bed for tars and light hydrocarbons reformation and NH3 decomposition, and a 6) Cu-based LT-WGS catalyst bed. Simulated biomass-derived syngas containing a multitude of inorganic contaminants (H2S, AsH3, HCl, and NH3) and hydrocarbon additives (methane, ethylene, benzene, and naphthalene) was used to demonstrate process effectiveness. The efficiency of the process was demonstrated for a period of 175 hours, during which no signs of deactivation were observed. Post-run analysis revealed small levels of sulfur slipped through the sorbent bed train to the two downstream catalytic beds. Future improvements could be made to the trace metal polishing sorbent to ensure complete inorganic contaminant removal (to low ppb level) prior to the catalytic steps. However, dual, regenerating ZnO beds were effective for continuous removal for the vast majority of the sulfur present in the feed gas. The process was effective for complete AsH3 and HCl removal. The steam reforming catalyst completely reformed all the hydrocarbons present in the feed (methane, ethylene, benzene, and naphthalene) to additional syngas. However, post-run evaluation, under kinetically-controlled conditions, indicates deactivation of the steam reforming catalyst. Spent material characterization suggests this is attributed, in part, to coke formation, likely due to the presence of benzene and/or naphthalene in the feed. Future adaptation of this technology may require dual, regenerable steam reformers. The process and materials described in this report hold promise for a warm cleanup of a variety of contaminant species within warm syngas.

Environmental Molecular Sciences Laboratory↗

In-line chemical sensor deployment in a tritium plant

The Savannah River Tritium Plant (TP) relies on well understood but aging sensor technology for process gas analysis. The use of alternative sensing and detection technologies for in-line and real-time analysis would aid process control and optimization. The TP upgrading follows a 2-phase projects. In the first phase, TP sensing requirements were determined by a team of process experts. Meanwhile, Savannah River National Laboratory sensor experts identified candidate technologies and related them to the TP processing requirements. The resulting road-map links the candidate technologies to actual plant needs. In the second phase an instrument demonstration station was established within a TP glove box in order to provide accurate assessments of how a candidate sensor technology would perform in a contaminated process environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Laboratory Analytical Methods for Uranium Analysis Superior Steel FUSRAP Site - 16606

The Superior Steel Site processed uranium metal in support of the Atomic Energy Commission's fuel-element development program in the 1950's, and was subsequently classified as a Formerly Utilized Sites Remedial Action Program (FUSRAP) Site. Previous investigations at the site identified uranium contamination both inside and outside the buildings associated with historic uranium metalworking activities. The U.S. Army Corps of Engineers (USACE) is currently engaged in the Remedial Investigation (RI) phase in accordance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) of 1980, as amended. As part of the RI, gamma spectroscopy analysis of environmental samples was performed on-site using a laboratory-grade, high-purity germanium (HPGe) spectrometer. The gamma spectroscopy analysis included isotopes of uranium and their progeny. As a quality assurance measure, a subset of samples already analyzed on-site were sent to a certified, commercial, off-site laboratory for analysis using a suite of analytical methods including gamma spectroscopy, alpha spectroscopy, and mass spectroscopy. As an element of the quality assurance program implemented for the RI, an assessment of the correlations between the various analytical methods employed by both the on-site and off-site laboratory was performed. This assessment revealed inconsistencies between on-site and off-site gamma spectroscopy analytical results, which raised concerns about the appropriateness and suitability of the analytical data. To resolve the data quality concerns and better understand the source(s) of analytical results variability, the Superior Steel RI team (USACE together with its contractor, Amec Foster Wheeler) developed a quality control test whose design objective was to control or practically eliminate sampling and sample preparation variability in order to focus more clearly on analytical variability. This paper discusses the results of this supplemental quality control test, showing the differences in the various analytical methods (both on-site and off-site). It demonstrates in a practical and real world setting how sample preparation and analytical variability, if not controlled and understood can impact data quality and data defensibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Healthy Zero Energy Buildings (HZEB) Program - Cross-Sectional Study of Contaminant Levels, Source, Strengths, and Ventilation Rates in Retail Stores

This field study measured ventilation rates and indoor air quality parameters in 21 visits to retail stores in California. The data was collected to guide the development of new, science-based commercial building ventilation rate standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. Data collection occurred between September 2011 and March 2013. Three types of stores participated in this study: grocery stores, furniture/hardware stores, and apparel stores. Ventilation rates and indoor air contaminant concentrations were measured on a weekday, typically between 9 am and 6 pm. Ventilation rates measured using a tracer gas decay method exceeded the minimum requirement of California’s Title 24 Standard in all but one store. Even though there was adequate ventilation according to Title 24, concentrations of formaldehyde, acetaldehyde, and acrolein exceeded the most stringent chronic health guidelines. Other indoor air contaminants measured included carbon dioxide (CO{sub 2}), carbon monoxide (CO), ozone (O{sub 3}), and particulate matter (PM). Concentrations of CO{sub 2} were kept low by adequate ventilation, and were assumed low also because the sampling occurred on a weekday when retail stores were less busy. CO concentrations were also low. The indoor-outdoor ratios of O{sub 3} showed that the first-order loss rate may vary by store trade types and also by ventilation mode (mechanical versus natural). Analysis of fine and ultrafine PM measurements showed that a substantial portion of the particle mass in grocery stores with cooking-related emissions was in particles less than 0.3 μm. Stores without cooking as an indoor source had PM size distributions that were more similar indoors and outdoors. The whole-building emission rates of volatile organic compounds (VOCs) and PM were estimated from the measured ventilation rates and indoor and outdoor contaminant concentrations. Mass balance models were then used to determine the ventilation rates, filtration strategies, or source reductions needed to maintain indoor contaminant concentrations below reference levels. Several scenarios of potential concern were considered: (i) formaldehyde levels in furniture/hardware stores, (ii) contaminants associated with cooking (e.g., PM, acrolein, and acetaldehyde) in grocery stores, and (iii) outdoor contaminants (e.g., PM and O{sub 3}) impacting stores that use natural ventilation. Estimated formaldehyde emission rates suggest that retail stores would need to ventilate at levels far exceeding the current Title 24 requirement to lower indoor concentrations below California’s stringent formaldehyde reference level. Given the high costs of providing ventilation but only modest chronic health benefit is expected, effective source control is an attractive alternative, as demonstrated by some retail stores in this study. Predictions showed that grocery stores need MERV 13 air filters, instead of MERV 8 filters that are more commonly used, to maintain indoor PM at levels that meet the chronic health standards for PM. Exposure to acrolein is a potential health concern in grocery stores, and should be addressed by increasing the use of kitchen range hoods or improving their contaminant removal efficiency. In stores that rely on natural ventilation, indoor PM can be a health concern if the stores are located in areas with high outdoor PM. This concern may be addressed by switching to mechanical ventilation when the outdoor air quality is poor, while continuing natural ventilation when outdoor air quality is good.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Arsenic stabilization performance of a novel starch-modified Fe-Mn binary oxide colloid

Arsenic (As) is an environmentally hazardous contaminant and can be a serious threat to human health. In China, remediation needs for a large number of As-contaminated sites renders a strong demand for efficient remedial reagents and cost effective approaches. In this study, a novel starch-modified Fe-Mn binary oxide (SFM), an amorphous colloidal material, has been synthesized as a remedial reagent and its As stabilization performance has been evaluated. A set of laboratory batch experiments were carried out by directly adding SFM of different dosages into three contaminated soils. Results demonstrated that SFM could transform As in soil from non-specifically and specifically sorbed fractions to the more stable form bounded to amorphous iron hydrous oxides, thus reducing the As concentration in TCLP leachates by 42.0-93.2%. Results from adsorption tests and microscopic analysis indicated that the interactions between SFM and As are mainly controlled by adsorption, oxidation, and precipitation processes. SFM has abundant surface hydroxyl groups, with excellent adsorption properties for both As(V) and As(III), with the maximum adsorption capacities of 160.63 and 284.64 mg/g respectively at pH 7.0. The adsorption process closely fitted pseudo second-order kinetics and Freundlich isotherm model. SFM could increase soil Eh and oxidize As(III) to As(V), which facilitated the As stabilization in soilColloidal iron-based material directly used for stabilization in As contaminated soils is reported here for the first time. Starch modification improves both the reactivity and mobility of SFM in soil. Our findings propose an efficient and convenient reagent for As remediation in soil.

Yan, Xiulan↗

The Use of Subsurface Barriers to Support Treatment of Metals and Reduce the Flux of Tritium to Fourmile Branch at the Savannah River Site in South Carolina - 13358

The Savannah River Site (SRS) produced tritium, plutonium, and special nuclear materials for national defense, medicine, and the space programs. Acidic groundwater plumes containing metals, metallic radionuclides, non-metallic radionuclides and tritium sourced from the F and H Area Seepage Basins have impacted the surface water of Fourmile Branch on SRS. Tritium releases from Fourmile Branch have impacted the water quality within areas of the Savannah River adjacent to the SRS, and this circumstance has been an ongoing regulatory concern. The F and H Area Seepage Basins operated until 1988 for the disposition of deionized acidic waste water from the F and H Separations Facilities. The waste water contained dilute nitric acid and low concentrations of non-radioactive metals, and radionuclides, with the major isotopes being Cs-137, Sr-90, U-235, U-238, Pu-239, Tc-99, I-129, and tritium. The tritium concentration in the waste water was relatively elevated because there is not a practicable removal method in water. The acid content of the waste water during the operational period of the basins was equal to 12 billion liters of nitric acid. The seepage basins were closed in 1988 and backfilled and capped by 1991. The plumes associated with the F and H basins cover an area of nearly 2.4 square kilometers (600 acres) and discharge along ∼2,600 meters of Fourmile Branch. The acidic nature of the plumes and their overall discharge extent along the branch represent a large challenge with respect to reducing contaminant flux to Fourmile Branch. The introduction of nitric acid into the groundwater over a long time effectively reduced the retardation of metal migration from the basins to the groundwater and in the groundwater to Fourmile Branch, because most negatively charged surfaces on the aquifer materials were filled with hydrogen ion. Two large pump and treat systems were constructed in 1997 and operated until 2003 in an attempt to capture and control the releases to Fourmile Branch. The operating cost, including waste disposal, for the two systems was ∼$1.3 M/month. Both systems employed reinjection of tritiated water up gradient of the extraction, and produced large quantities of waste from non-tritium isotopes and metals removal prior to reinjection. Both systems were determined to be ineffective and potentially detrimental with respect to limiting the flux of contaminants to Fourmile Branch. After it became apparent that there was very little benefit to continued operation of the systems, and the staggering cost of operations was recognized by the SRS and regulators, a new remedy was developed. The new system uses vertical subsurface barriers to redirect groundwater flow to limit the transport of contaminants to the stream. The barriers were constructed of acid resistant grout using deep soil mixing techniques. The grout mixture used low swelling clay, fly ash, and sodium hydroxide to form a pozzolana material with low permeability and low strength. The SRS and regulators agreed to a series of remedial goals, with the first goal to reduce tritium flux to the stream by 70% and bring constituents other than tritium to groundwater protection standards. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chemistry and Formation of the Beilby Layer During Polishing of Fused Silica Glass

The chemical characteristics and the proposed formation mechanisms of the modified surface layer (called the Beilby layer) on polished fused silica glasses are described. Fused silica glass samples were polished using different slurries, polyurethane pads, and at different rotation rates. The concentration profiles of several key contaminants, such as Ce, K, and H, were measured in the near surface layer of the polished samples using Secondary Ion Mass Spectroscopy (SIMS). The penetration of K, originating from KOH used for pH control during polishing, decreased with increase in polishing material removal rate. In contrast, penetration of the Ce and H increased with increase in polishing removal rate. In addition, Ce penetration was largely independent of the other polishing parameters (e.g., particle size distribution and the properties of the polishing pad). The resulting K concentration depth profiles are described using a two-step diffusion process: (1) steady-state moving boundary diffusion (due to material removal during polishing) followed by (2) simple diffusion during ambient postpolishing storage. Using known alkali metal diffusion coefficients in fused silica glass, this diffusion model predicts concentration profiles that are consistent with the measured data at various polishing material removal rates. On the other hand, the observed Ce profiles are inconsistent with diffusion based transport. Rather we propose that Ce penetration is governed by the ratio of Ce–O–Si and Si–O–Si hydrolysis rates; where this ratio increases with interface temperature (which increases with polishing material removal rate) resulting in greater Ce penetration into the Beilby layer. Calculated Ce surface concentrations using this mechanism are in good agreement to the observed change in measured Ce surface concentrations with polishing material removal rate. In conclusion, these new insights into the chemistry of the Beilby layer, combined together with details of the single particle removal function during polishing, are used to develop a more detailed and quantitative picture of the polishing process and the formation of the Beilby layer.