Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Conditional Normalizing Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

M.I.T. Stirling-cycle heat transfer apparatus

The design and construction of a two-cylinder apparatus to measure heat transfer under conditions of oscillating pressure and oscillating flow such as found in Stirling-cycle machines are described. The apparatus consists of two large single-stage air compressors joined by a rigid drive shaft between the two crack shafts, and is powered by a 25-hp variable speed DC motor. The apparatus is capable of measuring heat transfer while velocity and pressure change over the range of dimensionless parameters normally found in Stirling cycle machines. It allows each parameter to be varied independently and easily. Instrumentation for the apparatus is adequate for measurement of pressure, time, gas and wall temperature, wall heat flux, and gas velocity. It yields preliminary data which show that the apparatus and data acquisition are operating satisfactorily and produce reasonable results.

Smith, Joseph L., Jr.↗

Unveiling the High Energy Obscured Universe: Hunting Collapsed Objects Physics

A large part of energy from space is coming from collapsing stars (SN, Hypernovae) and collapsed stars (black holes, neutron stars and white dwarfs). The peak of their energy release is in the hard-X and gamma-ray wavelengths where photons are insensitive to absorption and can travel from the edge the Universe or the central core of the Galaxy without loosing the primordial information of energy, time signature and polarization. The most efficient process to produce energetic photons is gravitational accretion of matter from a "normal" star onto a collapsed companion (L~GxMcollxdMacc/dtx( 1Rdisc)-dMacc/dt x c2), exceeding by far the nuclear reaction capability to generate high energy quanta. Thus our natural laboratory for "in situ" investigations are collapsed objects in which matter and radiation co-exist in extreme conditions of temperature and density due to gravitationally bent geometry and magnetic fields. This is a unique opportunity to study the physics of accretion flows in stellar mass and super-massive Black Holes (SMBHs), plasmoids generated in relativistic jets in galactic microQSOs and AGNs, ionised plasma interacting at the touching point of weakly magnetized NS surface, GRB/Supernovae connection, and the mysterious origins of "dark" GRB and X-ray flash.

Ubertini, P.↗

ITER Port Interspace Pressure Calculations

The ITER Vacuum Vessel (VV) is equipped with 54 access ports. Each of these ports has an opening in the bioshield that communicates with a dedicated port cell. During Tokamak operation, the bioshield opening must be closed with a concrete plug to shield the radiation coming from the plasma. This port plug separates the port cell into a Port Interspace (between VV closure lid and Port Plug) on the inner side and the Port Cell on the outer side. This paper presents calculations of pressures and temperatures in the ITER (Ref. 1) Port Interspace after a double-ended guillotine break (DEGB) of a pipe of the Tokamak Cooling Water System (TCWS) with high temperature water. It is assumed that this DEGB occurs during the worst possible conditions, which are during water baking operation, with water at a temperature of 523 K (250 C) and at a pressure of 4.4 MPa. These conditions are more severe than during normal Tokamak operation, with the water at 398 K (125 C) and 2 MPa. Two computer codes are employed in these calculations: RELAP5-3D Version 4.2.1 (Ref. 2) to calculate the blowdown releases from the pipe break, and MELCOR, Version 1.8.6 (Ref. 3) to calculate the pressures and temperatures in the Port Interspace. A sensitivity study has been performed to optimize some flow areas.

Interspace ITER Vacuum vessel↗

Investigation of Thermal Stress Convection in Nonisothermal Gases under Microgravity Conditions

The project has sought to ascertain the veracity of the Burnett relations, as applied to slow moving, highly nonisothermal gases, by comparison of convection and stress predictions with those generated by the DSMC method. The Burnett equations were found to provide reasonable descriptions of the pressure distribution and normal stress in stationary gases with a 1-D temperature gradient. Continuum/Burnett predictions of thermal stress convection in 2-D heated enclosures, however, are not quantitatively supported by DSMC results. For such situations, it appears that thermal creep flows, generated at the boundaries of the enclosure, will be significantly larger than the flows resulting from thermal stress in the gas.

Mackowski, Daniel W.↗

Buoyancy Effects on Concurrent Flame Spread Over Thick PMMA

The flammability of combustible materials in a spacecraft is important for fire safety applications because the conditions in spacecraft environments differ from those on earth. Experimental testing in space is difficult and expensive. However, reducing buoyancy by decreasing ambient pressure is a possible approach to simulate on-earth the burning behavior inside spacecraft environments. The objective of this work is to determine that possibility by studying the effect of pressure on concurrent flame spread, and by comparison with microgravity data, observe up to what point low-pressure can be used to replicate flame spread characteristics observed in microgravity. Specifically, this work studies the effect of pressure and microgravity on upward/concurrent flame spread over 10 mm thick polymethyl methacrylate (PMMA) slabs. Experiments in normal gravity were conducted over pressures ranging between 100 and 40 kPa and a forced flow velocity of 200 mm/s. Microgravity experiments were conducted during NASA’s Spacecraft Fire Experiment (Saffire II), on board the Cygnus spacecraft at 100 kPa with an air flow velocity of 200 mm/s. Results show that reductions of pressure slow down the flame spread over the PMMA surface approaching that in microgravity. The data is correlated in terms of a non-dimensional mixed convection analysis that describes the convective heat transferred from the flame to the solid, and the primary mechanism controlling the spread of the flame. The extrapolation of the correlation to low pressures predicts well the flame spread rate obtained in microgravity in the Saffire II experiments. Similar results were obtained by the authors with similar experiments with a thin composite cotton/fiberglass fabric (published elsewhere). Both results suggest that reduced pressure can be used to approximately replicate flame behavior of untested gravity conditions for the burning of thick and thin solids. This work could provide guidance for potential ground-based testing for fire safety design in spacecraft and space habitats.

Environmental conditions↗

Backward-propagating MeV electrons from 10{sup 18} W/cm{sup 2} laser interactions with water

We present an experimental study of the generation of ∼MeV electrons opposite to the direction of laser propagation following the relativistic interaction at normal incidence of a ∼3 mJ, 10{sup 18} W/cm{sup 2} short pulse laser with a flowing 30 μm diameter water column target. Faraday cup measurements record hundreds of pC charge accelerated to energies exceeding 120 keV, and energy-resolved measurements of secondary x-ray emissions reveal an x-ray spectrum peaking above 800 keV, which is significantly higher energy than previous studies with similar experimental conditions and more than five times the ∼110 keV ponderomotive energy scale for the laser. We show that the energetic x-rays generated in the experiment result from backward-going, high-energy electrons interacting with the focusing optic, and vacuum chamber walls with only a small component of x-ray emission emerging from the target itself. We also demonstrate that the high energy radiation can be suppressed through the attenuation of the nanosecond-scale pre-pulse. These results are supported by 2D particle-in-cell simulations of the laser-plasma interaction, which exhibit beam-like backward-propagating MeV electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Variations of a global constraint factor in cracked bodies under tension and bending loads

Elastic-plastic finite-element analyses were used to calculate stresses and displacements around a crack in finite-thickness plates for an elastic-perfectly plastic material. Middle- and edge-crack specimens were analyzed under tension and bending loads. Specimens were 1.25 to 20 mm thick with various widths and crack lengths. A global constraint factor alpha(sub g), an averaged normal-stress to flow-stress ratio over the plastic region, was defined to simulate three-dimensional (3D) effects in two-dimensional (2D) models. For crack lengths and uncracked ligament lengths greater than four times the thickness, the global constraint factor was found to be nearly a unique function of a normalized stress-intensity factor (related to plastic-zone size to thickness ratio) from small- to large-scale yielding conditions for various specimen types and thickness. For crack length-to-thickness ratios less than four, the global constraint factor was specimen type, crack length and thickness dependent. Using a 2D strip-yield model and the global constraint factors, plastic-zone sizes and crack-tip displacements agreed reasonably well with the 3D analyses. For a thin sheet aluminum alloy, the critical crack-tip-opening angle during stable tearing was found to be independent of specimen type and crack length for crack length-to-thickness ratios greater than 4.

Newman, J. C., Jr.↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Estimation of the time for steam generator trip due to cyber intrusions

The time required to trip a pressurized water reactor (PWR) by inserting malicious signals into its steam generator (SG) control system has been studied using the Generic PWR (GPWR) Simulator. A semi-analytical model is developed to approximately reproduce the simulator response and understand the dynamics of the control unit. A series of two proportional-integral controllers determines control action according to preset constants, the readings from the feedwater level sensor, and those from feedwater and steam flowrate transmitters. It is observed that the most important factor that determines whether a trip will occur is how much additional water is added to or withheld from the SG over time compared to normal operating conditions. In order to determine the effects of control action on the SG, changes in mass inventory are considered. This approach models the SG water level as a function of mass inventory and has a backward temporal memory. A Python interface is developed for the GPWR framework to automatically simulate different spoofing scenarios and post-process the related data. We observe that the trip times predominantly depend on flow mismatch and/or level errors. Controller parameters, including the integral time and gain constants, either speed up or slow down the rate of progression to a trip setpoint but do not cause a trip by themselves. The reactor can trip on a high-level signal when the reading crosses above 78%, increased from its reference level of 57%, or a low-level reading when it is below 25%. The present results show roughly how long the operators would have to respond to an attack, given a specific set of spoofing signals within the issue space analyzed. Furthermore, we have generated a simple surface by fitting a combination of exponential functions to the data obtained from the GPWR Simulator. In general, trips on a low level have been observed to occur faster than those on a high level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Two-fluid equilibrium with flow: FLOW2

The effects of finite macroscopic velocities on axisymmetric ideal equilibria are examined using the two-fluid (ions and electrons) model. A new equilibrium solver, the code FLOW2, is introduced for the two-fluid model and used to investigate the importance of various flow patterns on the equilibrium of tight aspect ratio (NSTX) and regular tokamak (DIII-D) configurations. Several improvements to the understanding and calculation of two-fluid equilibria are presented, including an analytical and numerical proof of the single-fluid and static limits of the two-fluid model, a discussion of boundary conditions, a user-friendly free-function formulation, and the explicit evaluation of velocity components normal to magnetic surfaces.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Liquid jet impingement normal to a disk in zero gravity

An experimental and analytical investigation was conducted to determine the free surface shapes of circular jets impinging normal to sharp-edged disks in zero gravity. Experiments conducted in a zero gravity drop tower yielded three distinct flow patterns which were classified in terms of the relative effects of surface tension and inertial forces. An order of magnitude analysis was conducted indicating regions where viscous forces were not significant when computing free surface shapes. The free surface analysis was simplified by transforming the governing potential flow equations and boundary conditions into the inverse plane. The resulting nonlinear equations were solved numerically and comparisons were made with the experimental data for the inertia dominated regime.

Labus, T. L.↗

Radiative properties of a nickel based superalloy: Inconel 617 - After simulated earth reentry

Experimental results are presented to show the effect of environmental simulation exposures of convective heating and of radiant heating on the spectral (1.0 to 14 micrometers) and total emittance of oxidized Inconel 617. Convective heating exposures were conducted in an arc heated supersonic wind tunnel using a wedge-shaped specimen configuration. Radiant tests were conducted in dry air at a flow velocity of several meters per second. Convective heating specimens were subjected to 8, 20 and 38 heating cycles of 15-minutes duration and radiant heating specimens were tested for 10, 20, 50 and 100 one-half hour heating cycles. Changes in radiative properties are discussed in terms of changes in composition and morphology resulting from the exposure tests. Total normal emittance did not significantly change from the statically oxidized condition after either type of exposure, and it remained above 0.80 at 1260K for all cases. Although spectral changes were observed on post exposure specimens at wavelengths less than 2.0 micrometers and greater than 15 micrometers, these changes have no influence on total emittance at 1260K.

Cunnington, G. R.↗

Heat transfer deterioration in tubes caused by bulk flow acceleration due to thermal and frictional influences

Severe deterioration of forced convection heat transfer can be encountered with compressible fluids flowing through strongly heated tubes of relatively small bore as the flow accelerates and turbulence is reduced because of the fluid density falling (as the temperature rises and the pressure falls due to thermal and frictional influence). The model presented here throws new light on how the dependence of density on both temperature and pressure can affect turbulence and heat transfer and it explains why the empirical equations currently available for calculating effectiveness of forced convection heat transfer under conditions of strong non-uniformity of fluid properties sometimes fail to reproduce observed behaviour. It provides a criterion for establishing the conditions under which such deterioration of heat transfer might be encountered and enables heat transfer coefficients to be determined when such deterioration occurs. The analysis presented here is for a gaseous fluid at normal pressure subjected strong non-uniformity of fluid properties by the application of large temperature differences. Thus the model leads to equations which describe deterioration of heat transfer in terms of familiar parameters such as Mach number, Reynolds number and Prandtl number. It is applicable to thermal power plant systems such as rocket engines, gas turbines and high temperature gas-cooled nuclear reactors. However, the ideas involved apply equally well to fluids at supercritical pressure. Impairment of heat transfer under such conditions has become a matter of growing interest with the active consideration now being given to advanced water-cooled nuclear reactors designed to operate at pressures above the critical value. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simulation and Modeling of Hypersonic Turbulent Boundary Layers Subject to Adverse Pressure Gradients due to Concave Streamline Curvature

Direct numerical simulations (DNS) of adverse-pressure-gradient turbulent boundary layers over a planar concave wall are presented for a nominal freestream Mach number of 5, with the objective of assessing the limitations of the currently available Reynolds-averaged Navier-Stokes (RANS) models. The wall geometry and flow conditions of the DNS are representative of the experimental data for a Mach 4.9 turbulent boundary layer that was tested on a two-dimensional planar concave wall model in the high-speed blow-down wind tunnel located at the National Aerothermochemistry Laboratory at Texas A&M University (TAMU). The DNS was validated against the experimental results of TAMU for the same flow conditions and wall geometry. An analysis of the DNS datasets was also conducted to provide an assessment of the validity of Morkovin’s hypothesis and the strong Reynolds analog for turbulence subject to mechanical nonequilibrium. In addition to the DNS results, RANS predictions are obtained by using the Baldwin-Lomax (BL), Spalart-Allmaras (SA), and the k - w SST turbulence models. The comparisons between RANS and DNS showed little impact of an adverse pressure gradient on the accuracy of these models, at least up to an incompressible Clauser pressure gradient parameter of beta(sub inc) 1.22. While the Boussinesq assumption provided reasonable predictions for the Reynolds shear stress, it failed to adequately predict the normal components of the Reynolds stress.

turbulent boundary layers↗

Conjugate Heat Transfer Modeling of Salt-Filled Fuel Pins for Stable Salt Reactor Safety Analysis

The Stable Salt Reactor (SSR) combines the proven structural design of light water reactor fuel assemblies with the inherent safety and fuel-cycle advantages of molten salt technology. In its fast reactor configuration, the SSR utilizes recycled nuclear waste as fuel, sealed within narrow salt-filled fuel pins and cooled by a surrounding liquid salt coolant. Reliable transfer of heat from the molten fuel salt through the cladding to the external coolant is essential for both reactor safety and performance. This work investigates conjugate heat transfer (CHT) in the SSR’s salt-filled fuel pins using NekRS, a high-fidelity spectral element computational fluid dynamics (CFD) solver. The analyses capture internal natural convection within the molten fuel salt and external forced convection in the coolant, under steady-state and transient operating conditions. Parametric studies evaluate how variations in reactor power and coolant flow rate influence heat transfer distributions and system response. The high-fidelity CFD results are time-averaged and post-processed for direct comparison with moderate-fidelity Reynolds-averaged Navier–Stokes (RANS) models, and for the development of reduced-order models within the SAM system code. These validated models support fast-running safety analyses of normal and off-normal transients, improving predictive capability for key safety margins. By integrating advanced CFD with system-level safety tools, this study strengthens the modeling framework for SSR design, reduces uncertainty in molten salt CHT simulations, and accelerates the engineering and licensing of next-generation nuclear reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nonlinear aerodynamic effects on bodies in supersonic flow

The supersonic flow about generic bodies was analyzed to identify the elments of the nonlinear flow and to determine the influence of geometry and flow conditions on the magnitude of these nonlinearities. The nonlinear effects were attributed to separated-flow nonlinearities and attached-flow nonlinearities. The nonlinear attached-flow contribution was further broken down into large-disturbance effects and entropy effects. Conical, attached-flow bundaries were developed to illustrate the flow regimes where the nonlinear effects are significant, and the use of these boundaries for angle of attack and three-dimensional geometries was indicated. Normal-force and pressure comparisons showed that the large-disturbance and separated-flow effects were the dominant nonlinear effects at low supersonic Mach numbers and that the entropy effects were dominant for high supersonic Mach number flow. The magnitude of all the nonlinear effects increased with increasing angle of attack. A full-potential method, NCOREL, which includes an approximate entropy correction, was shown to provide accurate attached-flow pressure estimates from Mach 1.6 through 4.6.

Pittman, J. L.↗

An experimental study of a supercritical trailing-edge flow

An experimental study has been conducted of a transonic, turbulent, high-Reynolds-number blunt trailing-edge flow. The model shape and the surface pressure distribution are characteristics of a modern supercritical airfoil under shock-free conditions. Reynolds number and pressure gradient scaling of the boundary layer are relevant to airfoil applications. The data set is exceptionally accurate and consistent, with the momentum balance accounting for the flux of momentum to within 1 percent, except in the immediate vicinity of the blunt trailing edge. The experimental flow exhibits strong viscous-inviscid interaction and higher-order boundary-layer effects including strong adverse streamwise pressure gradient, significant normal pressure gradients associated with surface and streamline curvature, and significant wake curvature. Navier-Stokes calculations with a two-equation K-epsilon turbulence model predict the correct pressure distribution which demonstrates the utility of these engineering tools. The experiment approaches separation at the strailing edge. However, in comparison to the experiment, the calculations predict too high skin friction and insufficient displacement thickness growth. An analysis of the turbulent and mean flow fields reveals the turbulence model defects are likely in modeling the dissipation source and sink terms, and in the eddy viscosity relation.

Brown, J. L.↗

Flow Coupling Effects in Jet-in-Crossflow Flowfields

The combustor designer is typically required to design liner orifices that effectively mix air jets with crossflow effluent. CFD combustor analysis is typically used in the design process; however the jets are usually assumed to enter the combustor with a uniform velocity and turbulence profile. The jet-mainstream flow coupling is usually neglected because of the computational expense. This CFD study was performed to understand the effect of jet-mainstream flow coupling, and to assess the accuracy of jet boundary conditions that are commonly used in combustor internal calculations. A case representative of a plenum-fed quick-mix section of a Rich Burn/Quick Mix/Lean Burn combustor (i.e. a jet-mainstream mass-flow ratio of about 3 and a jet-mainstream momentum-flux ratio of about 30) was investigated. This case showed that the jet velocity entering the combustor was very non-uniform, with a low normal velocity at the leading edge of the orifice and a high normal velocity at the trailing edge of the orifice. Three different combustor-only cases were analyzed with uniform inlet jet profile. None of the cases matched the plenum-fed calculations. To assess liner thickness effects, a thin-walled case was also analyzed. The CFD analysis showed the thin-walled jets had more penetration than the thick-walled jets.

Bain, D. B.↗