Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computing, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Preface to the Proceedings of the 23rd Topical Conference on High-Temperature Plasma Diagnostics

Measurements of phenomena advance our understanding of the physical universe. As our understanding grows, more precise measurements are required, as are measurements of new quantities. Diagnosis of a plasma requires developing new instruments, also called diagnostics, as well as new ways to analyze, interpret, synthesize, and correlate their measurements. Further, as computing power increases and multi-physics codes improve their accuracy, more precise measurements are needed to guide future code developments and to validate predictions of these simulation codes. The Topical Conference on High-Temperature Plasma Diagnostics is focused on presenting and documenting the most recent advances in these instrumentation areas for plasmas. The 23rd occurrence of this biennial conference took place on December 14–17, 2020, and was hosted by Los Alamos National Laboratory. Originally scheduled for June 2020 in Santa Fe, New Mexico, the conference was postponed and then held virtually due to the global COVID-19 pandemic. Conference times were adjusted and presentations were scheduled to meet the needs of attendees in Europe, the USA, and Asia.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and Simulation for Safeguards [Slides]

The purpose of this talk is to give an overview of the role of modeling and simulation in Safeguards R&D and introduce you to (some of) the tools used. Some definitions are: (1) Modeling - the representation, often mathematical, of a process, concept, or operation of a system, often implemented by a computer program; (2) Simulation - the representation of the behavior or characteristics of one system through the use of another system, especially a computer program designed for the purpose; and (3) Safeguards - the timely detection of diversion of significant quantities of nuclear material. The role of modeling and simulation are: (1) Calculate amounts of material (plant modeling); (2) Calculate signatures of nuclear material etc. (source terms); and (3) Detector performance (radiation transport and detection). Plant modeling software (e.g. FACSIM) gives the flows and amount of material stored at all parts of the process. In safeguards this allow us to calculate the expected uncertainty of the mass and evaluate the expected MUF. We can determine the measurement accuracy required to achieve a certain performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Acquisition System of Nobeyama MKID Camera

We are developing a superconducting camera based on microwave kinetic inductance detectors (MKIDs) to observe 100-GHz continuum with the Nobeyama 45-m telescope. A data acquisition (DAQ) system for the camera has been designed to operate the MKIDs with the telescope. This system is required to connect the telescope control system (COSMOS) to the readout system of the MKIDs (MKID DAQ) which employs the frequency-sweeping probe scheme. The DAQ system is also required to record the reference signal of the beam switching for the demodulation by the analysis pipeline in order to suppress the sky fluctuation. The system has to be able to merge and save all data acquired both by the camera and by the telescope, including the cryostat temperature and pressure and the telescope pointing. A collection of software which implements these functions and works as a TCP/IP server on a workstation was developed. The server accepts commands and observation scripts from COSMOS and then issues commands to MKID DAQ to configure and start data acquisition. We made a commissioning of the MKID camera on the Nobeyama 45-m telescope and obtained successful scan signals of the atmosphere and of the Moon.

42 ENGINEERING↗

Development of a Data Acquisition System for Kinetic Inductance Detectors: Wide Dynamic Range and High Sampling Rate for Astronomical Observation

Microwave kinetic inductance detectors have a variety of potential applications in astronomical observations. We built a data acquisition system for kinetic inductance detectors combining a dedicated analog board and a commercially available digital board to meet the requirements of astronomical measurements, such as observation of the cosmic microwave background. This paper reports the status of the development of the data acquisition system. We have already achieved simultaneous readout through 120 channels using a direct down-conversion method to decode the signal. A variety of software has been developed and tested using the functionalities of the system and actual detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tetris-inspired detector with neural network for radiation mapping

Abstract Radiation mapping has attracted widespread research attention and increased public concerns on environmental monitoring. Regarding materials and their configurations, radiation detectors have been developed to identify the position and strength of the radioactive sources. However, due to the complex mechanisms of radiation-matter interaction and data limitation, high-performance and low-cost radiation mapping is still challenging. Here, we present a radiation mapping framework using Tetris-inspired detector pixels. Applying inter-pixel padding for enhancing contrast between pixels and neural networks trained with Monte Carlo (MC) simulation data, a detector with as few as four pixels can achieve high-resolution directional prediction. A moving detector with Maximum a Posteriori (MAP) further achieved radiation position localization. Field testing with a simple detector has verified the capability of the MAP method for source localization. Our framework offers an avenue for high-quality radiation mapping with simple detector configurations and is anticipated to be deployed for real-world radiation detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inverse design of photonic surfaces via multi fidelity ensemble framework and femtosecond laser processing

We demonstrate a multi-fidelity (MF) machine learning ensemble framework for the inverse design of photonic surfaces, trained on a dataset of 11,759 samples that we fabricate using high throughput femtosecond laser processing. The MF ensemble combines an initial low fidelity model for generating design solutions, with a high fidelity model that refines these solutions through local optimization. The combined MF ensemble can generate multiple disparate sets of laser-processing parameters that can each produce the same target input spectral emissivity with high accuracy (root mean squared errors < 2%). SHapley Additive exPlanations analysis shows transparent model interpretability of the complex relationship between laser parameters and spectral emissivity. Finally, the MF ensemble is experimentally validated by fabricating and evaluating photonic surface designs that it generates for improved efficiency energy harvesting devices. Our approach provides a powerful tool for advancing the inverse design of photonic surfaces in energy harvesting applications.

97 MATHEMATICS AND COMPUTING↗

The SciBooNE Data Acquisition System

SciBooNE started in June 2007 primarily to study neutrino and anti-neutrino interactions in the energy region below 1 GeV. The SciBooNE detector is located in Booster Neutrino Beamline at Fermi National Accelerator Laboratory. The SciBooNE data aquisition system consists of the readout software and an event builder, which collects data from each detector component (SciBar detector, an electromagnetic calorimeter, Muon Range Detector and GPS). The typical DAQ readout time per trigger is 20 ms, which is fast enough to take every beam spill. The system is also very stable and the probability of missing a beam spill due to the readout time is less than 0.002 %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A portable energy-sensitive cosmic neutron detection instrument

The construction and testing of a portable energy-sensitive neutron instrument are described. This instrument has been designed and constructed for the primary purpose of characterizing cosmic-ray neutron fields in the upper atmosphere and in cosmic reference field facilities. The instrument comprises a helium-3 proportional counter surrounded by 15 mm of lead and 140 mm of polyethylene creating a spherical structure with a diameter of 34 cm. The instrument also incorporates 12 boron-coated diodes, six on the outside of the polyethylene layer with six placed within the structure. The dimensions, materials, and arrangement of these in the instrument have previously been optimized with the MCNPX Monte Carlo simulation software to provide a compromise between the requirements of portability and spectral response. Testing took place at several locations and experimental data from the instrument's operation at the high-altitude Jungfraujoch laboratory in the Swiss alps are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impedance e-tongue instrument for rapid liquid assessment

We present a compact and easy to handle instrument developed to perform rapid analysis of liquids utilizing an 'electronic tongue' system. Briefly, the e-tongue used here is based on impedance measurements of an array of sensing units fabricated with ultrathin films of different materials deposited onto gold interdigitated electrodes. The instrument has the capability of measuring up to eight different sensor sets, each comprising an array of eight sensing units, and can perform a series of measurements in less than half of an hour. Additionally, there is a user-friendly software interface for instrument control, allowing the statistical correlation of samples using principal component analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High figure-of-merit ultrathin metal transparent electrodes incorporating a conductive grid

It is known that ultrathin (<10 nm) metal films (UTMFs) can achieve high level of optical transparency at the expense of the electrical sheet resistance. In this letter, we propose a design, the incorporation of an ad hoc conductive grid, which can significantly reduce the sheet resistance of UTMF based transparent electrodes, leaving practically unchanged their transparency. The calculated highest figure-of-merit corresponds to a filling factor and a grid spacing-to-linewidth ratio of 0.025 and 39, respectively. To demonstrate the capability of the proposed method the sheet resistance of a continuous 2 nm Ni film (>950 OMEGA/square) is reduced to approx6.5 OMEGA/square when a 100 nm thick Cu grid is deposited on it. The transparency is instead maintained at values exceeding 75%. These results, which can be further improved by making thicker grids, already demonstrate the potential in applications, such as photovoltaic cells, optical detectors and displays.

36 MATERIALS SCIENCE↗

Experimental Modal Analysis on a Rotating Fan Using Tracking-CSLDV

Continuous Scan Laser Doppler Vibrometry (CSLDV) modifies the traditional mode of operation of a vibrometer by sweeping the laser measurement point continuously over the structure while measuring, enabling one to measure spatially detailed mode shapes quickly and minimizing the inconsistencies that can arise if the structure or test conditions change with time. When a periodic scan path is employed, one can decompose the measurement into the response that would have been measured at each point traversed by the laser and obtain the structure's mode shapes and natural frequencies using conventional modal analysis software. In this paper, continuous-scan vibrometry is performed on a rotating fan, using computer controlled mirrors to track the rotating fan blades while simultaneously sweeping the measurement point over the blades. This has the potential to circumvent the difficulty of attaching contact sensors such as strain gauges, which might modify the structure and invalidate the results. In this work, impact excitation was used to excite a 3-blade fan rotating at various speeds, and the blades were scanned with a cloverleaf pattern that captured the bending of all three blades simultaneously. Some specialized signal processing is helpful in minimizing the effect of rotation frequency harmonics in the measurements, and specific scan strategies are needed to avoid those frequencies, both of these issues are discussed in the paper. While noise in the laser vibrometer does pose some difficulty, the results show that several modes could be extracted and that the tracking-CSLDV results agree with measurements obtained from the parked fan.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SIMS instrumentation and methodology for mapping of co-localized molecules

We describe an innovative mode for localizing surface molecules. In this methodology, individual C{sub 60} impacts at 50 keV are localized using an electron emission microscope, EEM, synchronized with a time-of-flight mass spectrometer for the detection of the concurrently emitted secondary ions. The instrumentation and methodologies for generating ion maps are presented. The performance of the localization scheme depends on the characteristics of the electron emission, those of the EEM and of the software solutions for image analysis. Using 50 keV C{sub 60} projectiles, analyte specific maps and maps of co-emitted species have been obtained. The individual impact sites were localized within 1-2 μm. A distinctive feature of recording individual impacts is the ability to identify co-emitted ions which originate from molecules co-located within ∼10 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron-paramagnetic resonance detection with software time locking

A setup for electron paramagnetic resonance with narrow band digital detection is described. A low frequency reference tone is added to the radio frequency signal. This reference signal, after digital detection, is used to lock the resonance signal, even in the absence of hardware time locking among the radio frequency generator, the conversion local oscillators, and the sampling stage. Results obtained with 2,2-Diphenyl-1-Pycryl-Hydrazil are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of movement of the western and central belts of Peninsular Malaysia using GPS data analysis

Since the large earthquakes in Sumatera and Nias, there were some tremors incidents at Bukit Tinggi. Therefore, a study on the earth’s crust movement and the effects of the earthquake in Indonesia on the tectonic blocks of Peninsular Malaysia have been carried out using GPS data analysis. GPS data from five MyRTKnet stations within Peninsular Malaysia have been analyzed to monitor the movement of two major tectonic blocks of Peninsular Malaysia which are the western belt represented by the Behrang (BEHR) and UPM Serdang (UPMS) stations and the central belt represented by Bentong (BENT), Jerantut (JRNT) and Temerloh (TLOH) stations. GPS data recorded from 2005 to 2010 were analysed based on horizontal and vertical displacements of the respective stations by using Trimble Business Centre (TBC) software. Based on the results of accumulated displacements of recorded GPS data from January 2006 to December 2013, it shows that the western belt which represented by UPMS has shifted 0.096m towards northwest with changes of ellipsoidal height of +0.030m while the central belt which represented by TLOH has shifted 0.080m towards northwest with changes of ellipsoidal height of −0.015m. Meanwhile, BENT station which is located on the Bentong-Raub suture zone turns to its original position as well as JRNT station. However, BEHR station which are located in western belt do not show any movements. All of these movements may be due to the influence of reactive faults in the stations area stimulated by several large earthquakes that occurred in 2005 to 2010. Study on using the GPS data analysis and combine with integrated geophysical methods are necessary to understand in detail about the tectonic evolution of Peninsular Malaysia.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A firmware-defined digital direct-sampling NMR spectrometer for condensed matter physics

We report on the design and implementation of a new digital, broad-band nuclear magnetic resonance (NMR) spectrometer suitable for probing condensed matter. The spectrometer uses direct sampling in both transmission and reception. It relies on a single, commercially-available signal processing device with a user-accessible field-programmable gate array (FPGA). Its functions are defined exclusively by the FPGA firmware and the application software. Besides allowing for fast replication, flexibility, and extensibility, our software-based solution preserves the option to reuse the components for other projects. The device operates up to 400 MHz without, and up to 800 MHz with undersampling, respectively. Digital down-conversion with ±10 MHz passband is provided on the receiver side. The system supports high repetition rates and has virtually no intrinsic dead time. We describe briefly how the spectrometer integrates into the experimental setup and present test data which demonstrates that its performance is competitive with that of conventional designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-bit quantum random number generation by measuring positions of arrival photons

We report upon the realization of a novel multi-bit optical quantum random number generator by continuously measuring the arrival positions of photon emitted from a LED using MCP-based WSA photon counting imaging detector. A spatial encoding method is proposed to extract multi-bits random number from the position coordinates of each detected photon. The randomness of bits sequence relies on the intrinsic randomness of the quantum physical processes of photonic emission and subsequent photoelectric conversion. A prototype has been built and the random bit generation rate could reach 8 Mbit/s, with random bit generation efficiency of 16 bits per detected photon. FPGA implementation of Huffman coding is proposed to reduce the bias of raw extracted random bits. The random numbers passed all tests for physical random number generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-speed quantum-random number generation by continuous measurement of arrival time of photons

We demonstrate a novel high speed and multi-bit optical quantum random number generator by continuously measuring arrival time of photons with a common starting point. To obtain the unbiased and post-processing free random bits, the measured photon arrival time is converted into the sum of integral multiple of a fixed period and a phase time. Theoretical and experimental results show that the phase time is an independent and uniform random variable. A random bit extraction method by encoding the phase time is proposed. An experimental setup has been built and the unbiased random bit generation rate could reach 128 Mb/s, with random bit generation efficiency of 8 bits per detected photon. The random numbers passed all tests in the statistical test suite.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗