Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compact”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

A compact filtered x-ray diode array spectrometer for the National Ignition Facility: SENTINEL

Sentinel is a 16-channel, filtered x-ray diode array spectrometer that has been developed to measure ~1 keV–20 keV x-ray emission generated by the National Ignition Facility (NIF) laser. Unlike the large, fixed-port versions of this diagnostic that currently exist on the NIF (known as Dante), Sentinel is a Diagnostic Instrument Manipulator compatible such that it can be fielded along the polar or equatorial lines-of-sight—an essential new capability for characterizing the often anisotropic x-ray emission from laser-driven sources. Here, we present the diagnostic design along with preliminary diode calibrations and performance results. The novel, small-form-factor x-ray diode design allows for ≳5×–25× increased channel areal density over that of Dante, simultaneously enabling improved diagnostic robustness and fidelity of spectral reconstructions. While the Sentinel diagnostic is anticipated to improve line-of-sight spectral characterization of x-ray sources for a wide variety of programs on the NIF, the compact and portable design is also attractive to small- and mid-scale facilities with limited diagnostic real estate.

47 OTHER INSTRUMENTATION↗

Complete Stokes vector analysis with a compact, portable rotating waveplate polarimeter

Accurate calibration of polarization dependent optical elements is often necessary in optical experiments. A versatile polarimeter device to measure the polarization state of light is a valuable tool in these experiments. Here we report a rotating waveplate-based polarimeter capable of complete Stokes vector analysis of collimated light. Calibration of the device allows accurate measurements over a range of wavelengths, with a bandwidth of >30 nm in this implementation. A photo-interrupter trigger system supplies the phase information necessary for full determination of the Stokes vector. An Arduino microcontroller performs rapid analysis and displays the results on a liquid crystal display. The polarimeter is compact and can be placed anywhere on an optical table on a single standard post. The components to construct the device are only a fraction of the cost of commercially available devices while the accuracy and precision of the measurements are of the same order of magnitude.

47 OTHER INSTRUMENTATION↗

A compact x-ray diffraction system for dynamic compression experiments on pulsed-power generators

Pulsed-power generators can produce well-controlled continuous ramp compression of condensed matter for high-pressure equation-of-state studies using the magnetic loading technique. X-ray diffraction (XRD) data from dynamically compressed samples provide direct measurements of the elastic compression of the crystal lattice, onset of plastic flow, strength–strain rate dependence, structural phase transitions, and density of crystal defects, such as dislocations. Here, we present a cost-effective, compact, pulsed x-ray source for XRD measurements on pulsed-power-driven ramp-loaded samples. This combination of magnetically driven ramp compression of materials with a single, short-pulse XRD diagnostic will be a powerful capability for the dynamic materials’ community to investigate in situ dynamic phase transitions critical to equation of states. Finally, we present results using this new diagnostic to evaluate lattice compression in Zr and Al and to capture signatures of phase transitions in CdS.

47 OTHER INSTRUMENTATION↗

Ultra-compact x-ray spectrometer for high-repetition-rate laser–plasma experiments

Here, we present in this work the development of an ultra-compact, multi-channel x-ray spectrometer (UCXS). This diagnostic has been specially built and adapted to perform at high-repetition-rate (>1 Hz) for high-intensity, short-pulse laser plasma experiments. X-ray filters of varying materials and thicknesses are chosen to provide spectral resolution up to ΔE ≈ 1 keV over the x-ray energy range of 1–30 keV. These filters are distributed over a total of 25 channels, where each x-ray filter is coupled to a single scintillator. The UCXS is designed to detect and resolve a large variety of laser-driven x-ray sources such as low energy bremsstrahlung emission, fluorescence, and betatron radiation (up to 30 keV). Preliminary results from commissioning experiments at the ABL laser facility at Colorado State University are provided.

47 OTHER INSTRUMENTATION↗

Compact high repetition rate Thomson parabola ion spectrometer

Here, we present the development of a compact Thomson parabola ion spectrometer capable of characterizing the energy spectra of various ion species of multi-MeV ion beams from >10 20 W/cm 2 laser produced plasmas at rates commensurate with the highest available from any of the current and near-future PW-class laser facilities. This diagnostic makes use of a polyvinyl toluene based fast plastic scintillator (EJ-260), and the emitted light is collected using an optical imaging system coupled to a thermoelectrically cooled scientific complementary metal–oxide–semiconductor camera. This offers a robust solution for data acquisition at a high repetition rate, while avoiding the added complications and nonlinearities of micro-channel plate based systems. Different ion energy ranges can be probed using a modular magnet setup, a variable electric field, and a varying drift-distance. We have demonstrated operation and data collection with this system at up to 0.2 Hz from plasmas created by irradiating a solid target, limited only by the targeting system. With the appropriate software, on-the-fly ion spectral analysis will be possible, enabling real-time experimental control at multi-Hz repetition rates.

47 OTHER INSTRUMENTATION↗

Developing compact tuning fork thermometers for sub-mK temperatures and high magnetic fields

There is a growing demand for experiments on calorimetric and thermal transport measurements at ultra-low temperatures below 1 mK and high magnetic fields up to 16 T. Particularly, milligram-sized solid samples are of great interest. Here, we present the development of scalable thermometers based on quartz tuning fork resonators immersed in liquid 3 He and adapt hydrodynamic models to provide an improved description of temperature dependence in the high viscosity regime between 1 and 10mK. We demonstrate successful thermometer operation and discuss the feasibility of fast and compact thermal probes suitable for small samples.

47 OTHER INSTRUMENTATION↗

Compact in-vacuum gamma-ray spectrometer for high-repetition rate PW-class laser–matter interaction

With the advent of high repetition rate laser facilities, novel diagnostic tools compatible with these advanced specifications are required. This paper presents the design of an active gamma-ray spectrometer intended for these high repetition rate experiments, with particular emphasis on functionality within a PW level laser-plasma interaction chamber’s extreme conditions. The spectrometer uses stacked scintillators to accommodate a broad range of gamma-ray energies, demonstrating its adaptability for various experimental setups. In addition, it has been engineered to maintain compactness, electromagnetic pulse resistance, and ISO-5 cleanliness requirements while ensuring high sensitivity. The spectrometer has been tested in real conditions inside the PW-class level interaction chamber at the BELLA center, LBNL. The paper further details the calibration process, which utilizes a 60 Co radioactive source, and describes the unfolding technique implemented through a stochastic minimization method.

47 OTHER INSTRUMENTATION↗

Development of a compact magnetic spectrometer for use at the OMEGA Laser Facility and the National Ignition Facility

Measurement of proton spectra is an important diagnostic for a variety of high energy density physics experiments. Current diagnostics are either not designed to capture the spectrum of low-energy protons or are unsuitable for high debris experiments. To bridge the gap, a new CR-39 based compact magnetic spectrometer (MagSpec) has been developed to measure proton spectra in the 1–20 MeV energy range, with a particular focus on the low-energy (1–6 MeV) spectrum, for use in experiments at the OMEGA Laser Facility and the National Ignition Facility (NIF). In the MagSpec diagnostic, protons of different energies are dispersed as they pass through a magnetic field before impinging on a differentially filtered CR-39 surface, resulting in a spatial distribution of CR-39 tracks that corresponds to the energy spectrum. In this paper, we discuss details of the design and implementation of MagSpec on the NIF and OMEGA.

47 OTHER INSTRUMENTATION↗

A Grad-Shafranov model for compact quasisymmetric stellarators

A Grad-Shafranov equation (GSE) valid for compact quasisymmetric stellarators is derived by an asymptotic expansion around a vacuum field carried to first order. We obtain an equation for the existence of flux surfaces leading up to the GSE. The flux surface label must simultaneously satisfy the existence equation and the GSE, which generally leads to an overdetermined problem. We show how the overdetermined problem can be resolved within our model for a class of hybrid devices similar to that studied by Henneberg and Plunk [Phys. Rev. Res. 6, L022052 (2024)]. We are also able to solve the existence equation for flux surfaces analytically in the most general case by introducing a special coordinate system. This will enable us to carry out an optimization seeking to minimize the error in our GSE while obeying the flux surface existence equation, which will allow us to find solutions outside the class of hybrid devices. This will allow for a coarse-grained approximate search in the space of quasisymmetric equilibria that should be faster than a conventional stellarator optimization. Nevertheless, it would still be necessary to fine-tune the approximate solutions using conventional tools to obtain a more precise optimized equilibrium.

Nikulsin, N. (ORCID:0000000318611777)↗

Benchmarking core turbulence and transport predictions for an inductive compact tokamak reactor plasma

Motivated by the need for accurate, timely, and efficient calculations of plasma transport, predictions of plasma turbulence properties made using different TGLF saturation rules are benchmarked against corresponding predictions from linear and nonlinear gyrokinetic CGYRO simulations. This benchmarking is carried out using parameters taken from an inductive burning plasma scenario in a hypothetical compact high-field (R maj = 4 m, B T = 8 T) tokamak, lying in a much different regime of parameter space than either the TGLF calibration regime or current-day experiments. The core turbulent transport in this scenario is predicted to be dominated by ion temperature gradient (ITG) turbulence. In general, the ITG critical gradients predicted by various TGLF saturation rules are quite close to the CGYRO predictions. Both codes predict similar linear ITG growth rates and frequency spectra, as well as their scaling with R/L T i = −Rd ln(T i )/dr. However, TGLF systematically predicts unstable trapped-electron modes (TEMs) above k y ρ s ≃ 0.5 not seen by CGYRO for the same parameters, due to TGLF predicting a lower threshold in R/L T e than CGYRO for TEM onset. It is shown that for this scenario, nonlinear CGYRO simulations predict stiffer ITG turbulence than the TGLF SAT0 and SAT1 saturation rules, with energy fluxes close in magnitude and scaling with R/L T i to what is predicted by the SAT2 saturation rule. Self-consistent core profiles calculated using nonlinear CGYRO flux predictions and the PORTALS transport solver are shown to agree fairly well with corresponding predictions made using the TGLF SAT2 model, including a similar level of density peaking.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A compact in situ polarized 3He neutron spin filter for the diffractometer VULCAN at the Spallation Neutron Source

We have built and commissioned a compact in situ 3He polarizer based on spin-exchange optical pumping for the engineering materials diffractometer, named VULCAN, at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The system achieved 78% 3He polarization with a short pump-up time constant of 2.2 h. Its first deployment in an in situ half-polarized neutron diffraction experiment on a magnetic shape memory alloy, Ni–Mn–Ga, revealed changes in magnetization coupled to deformation twinning under compression. With this new capability, VULCAN has become the first diffractometer at SNS capable of performing polarized neutron experiments, opening new opportunities to study a wider range of magnetism-related material behaviors under varied thermal, mechanical, electrical, and/or magnetic fields.

Fu, Sichao [ORNL] (ORCID:0009000846771640)↗

A highly efficient, compact Yb:KYW laser for mobile precision systems

We have developed a promising scheme of a multimodediode-pumped ytterbium laser. The Yb:KYW laser in the cw regime demonstrates record-high differential (40%) and total optical (35%) efficiencies. Mode locking is realised, which allows the scheme to be used for the development of compact laser systems, such as mobile femtosecond precision synthesisers. The peculiarities of the laser operation and ways of further improving its efficiency are discussed. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a prototype compact fibre frequency synthesiser for mobile femtosecond optical clocks

A prototype compact fibre frequency synthesiser based on a femtosecond erbium fibre laser and an original hybrid highly nonlinear fibre is developed and preliminarily studied. This synthesiser will ensure an extremely low relative instability of synthesised frequencies (down to 10{sup -17}) with the use of a corresponding optical standard and will be used in mobile optical clocks. The realised frequency stabilisation principle makes the synthesiser universal and allows it to transfer the frequency stability of various types of optical standards to the synthesised radio- and optical frequencies. (extreme light fields and their applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-power compact laser with segmented longitudinal pumping of coupled laser channels

The characteristics of a compact Nd:YAG/Cr:YAG laser with segmented end pumping using a bundle of seven optical fibres are presented. In the regime of optical coupling of thus formed seven laser channels, 3-ns pulses with an energy up to 20 mJ, as well as their trains, are obtained. The used method makes it possible to scale the energy and power of lasers of this type with controlled spatial beam profile. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of the possibility of designing more compact DF lasers driven by combustion of preheated fuels

We report a theoretical calculation of the processes proceeding in the combustor of combustion-driven cw DF/HF chemical lasers with different mixtures of fuels preheated to high temperatures. Calculation results demonstrate a great effect of the preheating temperature on the yield of F atoms and strongest deactivator, on the primary dilution ratio Ψp and on the estimated specific power. When fuels are preheated to about 1300 K, the specific power is improved by about 74.2 %, and the total mass of the fuel is reduced by about 43 %, which makes it possible to realise a more compact and efficient design of combustion-driven cw DF/HF chemical lasers at elevated combustor pressures. Fuel preheating can facilitate the development of chemical lasers and high-power lasers based not only on airborne and space-borne platforms, but also on mobile ground-based platforms. (active media)

42 ENGINEERING↗

Compact transversely diode-pumped Nd :YAG laser with a self-pumped phase-conjugate multiloop cavity

A compact high-power repetitively pulsed Nd :YAG laser with transverse diode pumping and a multiloop self-pumped phase-conjugate cavity is presented. The obtained pulse trains have an energy of 2.55 J with beam quality M{sup 2}⩽1.2, a divergence of 0.35 mrad, and a spatial brightness of 7×10{sup 14} W cm{sup −2} sr{sup −1}. The peak power of single-frequency pulses exceeds 21 MW at a pulse energy of 230 mJ. The laser bandwidth is 300 MHz. (lasers)

42 ENGINEERING↗

Versatile and compact wide-range VUV spectrometer for quantitative measurements

Main parameters of a new scheme of a compact VUV grazing incidence spectrometer based on a plane amplitude diffraction grating are considered. The spectrometer will allow simultaneous detection of spectra at the +1st order diffraction edge with a sufficiently high ( λ/δ λ ∼ 150) spectral resolution and in the –1st order with a moderate resolution ( λ/δ λ ∼ 15 – 30), but in a very wide (5 – 200 nm) spectral range. The use of such a spectrometer is promising for measuring the absolute radiation yield in these spectral regions, which is necessary for the diagnostics and control of plasma radiation sources, including those intended for projection EUV nanolithography. (vuv spectroscopy)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact Q-switched Yb : Er laser with a pulse repetition rate of 10 Hz

A compact acousto-optically Q-switched Yb : Er laser emitting 20-ns pulses at λ = 1.5 μm with an energy of 8 mJ and a repetition rate of 10 Hz is developed. The laser radiation divergence at the exit of an optical forming system is 1 mrad. The experimental sample can stably operate in a wide temperature range with unchanged output parameters. The developed laser is 110 × 30 × 30 mm in size taking into account the dimensions of the optical forming system. Life tests demonstrated stable continuous operation of the sample for 50000 pulses. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗