Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CURRENT AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

KPiX, An Array of Self Triggered Charge Sensitive Cells Generating Digital Time and Amplitude Information

The Silicon Detector proposed for the International Linear Collider (ILC) requires electronic read-out that can be tightly coupled to the silicon detectors envisioned for the tracker and the electromagnetic calorimeter. The KPiX is a 1024-channel read-out chip that bump-bonds to the detector and communicates through a few digital signals, power, and detector bias. The KPiX front-end is a low-noise dual-range charge-amplifier with a dynamic range of 17 bit, achieved by autonomous switching of the feedback capacitor. The device takes advantage of the ILC duty cycle of 1 ms trains at 5 Hz rate by lowering the supply current after the data acquisition cycle for an average power consumption of <20 {micro}W/channel. During the 1 ms train, up to four events exceeding a programmable threshold can be stored, the amplitude as a voltage on a capacitor for subsequent digitization, the event time in digital format. The chip can be configured for other than ILC applications.

43 PARTICLE ACCELERATORS↗

Review of the Oak Ridge National Laboratory (ORNL) Neutronic Calculations Regarding the Conversion of the High Flux Isotope Reactor (HFIR) to the Use of Low Enriched Uranium (LEU) Fuel

In awareness of the risk caused by the proliferation of nuclear materials, the international community initiated in 1978 the Reduced Enrichment for Research and Test Reactors (RERTR) Program. The goal of the RERTR program is to seek solutions to convert the reactors using High Enriched Uranium (HEU) fuel ( 235 U/U ≥ 20 wt. %) to the use of Low Enriched Uranium (LEU) Fuel ( 235 U/U < 20 wt. %). Among the 200 reactors worldwide currently in the scope of the program, about 70 have been converted or shut down prior to conversion. In the U.S., six high reactors remain to be converted. One of the U.S. reactors is the High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory (ORNL). This multipurpose reactor is mainly used for neutron scattering experiments and isotope production. It has two fuel elements made of involute-shaped fuel plates. The ORNL Research Reactor Division (RRD) has prepared during FY2011 two series of calculations, one neutronic and one thermal-hydraulic (TH), in support of the conversion activities for HFIR. The neutronic calculations cover mainly the evaluation of the matrix of performance (cycle length and flux), the distribution of power in the fuel elements, kinetics parameters and reactivity coefficients. As defined by the RRD procedures, the calculations have to be reviewed. Per internal decision, the RRD proposed an external reviewer, Argonne National Laboratory (ANL). The results of the Argonne neutronic review are presented in this report. The results of the TH review are presented in a separate report. The main conclusion of the ORNL reactor physics analyses is that the proposed reference HFIR LEU core (using the so-called monolithic UMo fuel) could maintain the current level of performance (obtained with a HEU core at 85MW) if it is operated at 100MW. However, to operate within the same safety limits as the current HEU core, the thermal hydraulic analyses show that the peaking of the power distribution occurring at the bottom of the fuel plates has to be reduced. The RRD has found a potential solution by reducing the fuel thickness at the bottom of the fuel plate. This would require addition of an axial grading to the already radially-graded fuel. Thus, the review has been focused on independently recalculating all of the ORNL calculations and making an as fair as possible comparison between the current 85MW HEU core and the reference 100MW LEU core design. ORNL and ANL have used the same computational tools to perform the work. The codes MCNP and ORIGEN have been used to perform the steady state and depletion calculations, respectively. The communication between the two codes has been carried out by the code VESTA. Even though the code MCNP is able to handle complex geometries, it cannot model the involute shape. Nonetheless, ANL has developed an innovative methodology to model the involute shape with MCNP with an approximation that can be made as accurate as desired. Thus, ANL has been able to perform the calculations using an explicit (or discrete) description of the fuel elements. The current modeling used by ORNL consists in homogenizing the different fuel element components (cladding, fuel, coolant…). Although this method is easier to implement, it may also affect the reactor physics which may have an impact on the calculated results. Even though some differences in the physics parameters (flux for instance) have been detected between the HEU explicit (ANL) and homogenized (ORNL) models, they are small enough to not significantly impact the performance parameters. However, this is not the case for the LEU core where the differences in the physics parameters lead to significant differences in the performance parameters, especially the cycle length (found to be considerably longer in the explicit model). Nonetheless, the others parameters calculated by ANL (power distribution, kinetics parameters…) are in good agreement with those calculated by ORNL. Some inconsistencies have been detected in the original ORNL inputs that have been corrected in the reference ones used by ANL for the review and, therefore, the cycle length difference between the LEU homogenized and explicit models has been amplified. Consequently, the ANL comparison of the HFIR HEU and LEU cores has given different results than the ORNL results. The ORNL matrix of performance for the 100MW LEU reference design shows that the reactor cycle length would be as long and the flux as high as the current 85MW HEU core. In contrast, the ANL matrix of performance shows that the 100MW LEU design would have a significantly longer cycle length (~33days) than the current 85MW HEU core (~25days). In addition, it has been shown that, if the reactor is operated for 33days, the neutron fluence would be high enough to increase the overall reactor performance by a significant factor. If the reactor is forced to shut down after 25days, calculations show that the neutron flux would be high enough to maintain the performance of the neutron scattering experiments but losses are predicted to occur in several irradiation facilities. Increasing the cycle length may not be possible for other reasons. For instance, a longer cycle length can increase the cumulative oxide layer thickness growth on the plate. The increase in the neutron fluence may affect the lifetime of the reactor vessel and, by reducing the time for maintenance, pose operational challenges. An assessment of these as well as other potential questions associated with a 33 day cycle length is needed. Since such an assessment has not been carried out, ANL cannot conclude that the ORNL reference LEU core should or could operate at 100MW. The conclusions of the ANL review are different than those of the ORNL investigation mainly because the explicit and homogenized methodologies used to model the core are different. In this report, an attempt is made to justify and explain as clearly as possible why the ANL methodology is thought to be better suited for HFIR analyses. It is acknowledged that because the ANL and ORNL LEU models have not been benchmarked against experiments, it is possible that doubts could be raised concerning the ability of the models to correctly capture all of the physics behavior of the reactor.

Bergeron, A.↗

Vapor-Phase-Gating-Induced Ultrasensitive Ion Detection in Graphene and Single-Walled Carbon Nanotube Networks

Designing ultrasensitive detectors often requires complex architectures, high-voltage operations, and sophisticated low-noise measurements. Here, it is shown that simple low-bias two-terminal DC-conductance values of graphene and single-walled carbon nanotubes are extremely sensitive to ionized gas molecules. Incident ions form an electrode-free, dielectric- or electrolyte-free, bias-free vapor-phase top-gate that can efficiently modulate carrier densities up to ≈0.6 × 10 13 cm -2 . Surprisingly, the resulting current changes are several orders of magnitude larger than that expected from conventional electrostatic gating, suggesting the possible role of a current-gain inducing mechanism similar to those seen in photodetectors. These miniature detectors demonstrate charge–current amplification factor values exceeding 10 8 A C -1 in vacuum with undiminished responses in open air, and clearly distinguish between positive and negative ions sources. At extremely low rates of ion incidence, detector currents show stepwise changes with time, and calculations suggest that these stepwise changes can result from arrival of individual ions. Lastly, these sensitive ion detectors are used to demonstrate a proof-of-concept low-cost, amplifier-free, light-emitting-diode-based low-power ion-indicator.

36 MATERIALS SCIENCE↗

Stimulation of nuclear receptor REV-ERBs regulates tumor necrosis factor-induced expression of proinflammatory molecules in C6 astroglial cells

Under physiological conditions, astrocytes maintain homeostasis in the CNS. Following inflammation and injury to the CNS, however, activated astrocytes produce neurotoxic molecules such as cytokines and chemokines, amplifying the initial molecular-cellular events evoked by inflammation and injury. Nuclear receptors REV-ERBα and REV-ERBβ (REV-ERBs) are crucial in the regulation of inflammation- and metabolism-related gene transcription. The current study sought to elucidate a role of REV-ERBs in rat C6 astroglial cells on the expression of inflammatory molecules following stimulation with the neuroinflammatory cytokine tumor necrosis factor (TNF). Stimulation of C6 cells with TNF (10 ng/ml) significantly increased the mRNA expression of CCL2, interleukin-6 (IL-6), inducible nitric oxide synthase (iNOS), and matrix metalloprotease (MMP)-9, but not fibroblast growth factor-2 (FGF-2), cyclooxygenase-2 (COX-2) and MMP-2. Treatment with either REV-ERB agonists GSK4112 or SR9009 significantly blocked TNF-induced upregulation of CCL2 mRNA and MMP-9 mRNA, but not IL-6 mRNA and iNOS mRNA expression. Furthermore, treatment with RGFP966, a selective histone deacetylase 3 (HDAC3) inhibitor, potently reversed the inhibitory effects of GSK4112 on TNF-induced expression of MMP-9 mRNA, but not CCL2 mRNA. Expression of Rev-erbs mRNA in C6 astroglial cells, primary cultured rat cortical and spinal astrocytes was confirmed by reverse transcription polymerase chain reaction. Together, the findings demonstrate an anti-inflammatory effect, downregulating of MMP-9 and CCL2 transcription, of astroglial REV-ERBs activation through HDAC3-dependent and HDAC3-independent mechanisms. - Highlights: • Rev-erbα mRNA and Rev-erbβ mRNA are expressed in C6 astroglial cells. • TNF increases the expression of CCL2, IL-6, MMP-9 and iNOS mRNA. • REV-ERB activation inhibits CCL2 mRNA and MMP-9 mRNA expression. • HDAC3 activity is involved in the inhibitory effect of REV-ERB on MMP-9 induction.

60 APPLIED LIFE SCIENCES↗

Conceptual design of the LHCD system on CFETR

With the capability of saving flux consumption in the current ramp up phase, controlling the safety factor (q) profile, providing the required off-axis current drive (CD), a lower hybrid current drive (LHCD) system was eventually determined to be used on the China Fusion Engineering Test Reactor (CFETR). Here, in this paper, a 20 MW/4.6 GHz system composed of 40 units of 500 kW continuous wave (CW) klystron amplifier is preliminarily designed. The feasibility of the frequency choice of 4.6 GHz in the physical aspect is discussed. In order to minimize the transmission loss, a TE01 over-mode of circular waveguide will be used in the transmission system. Although previous calculations indicates that high field side (HFS) launcher location results in waves damping at inner region than low field side (LFS) launcher, which is favorable for plasma stability, HFS launcher will be extremely difficult in engineering due to the limited space. Calculations show that the tritium breeding ratio (TBR) will be decreased by ~ 1.5% with HFS launcher, while it will be decreased by ~ 0.22% only with LFS launcher. As a result, the LH power will be coupled to plasma from the top port at LFS. The designed passive active multi-junction (PAM) launcher is arranged in an array of 5 rows and 8 columns with the height of 1181 mm and the width of 794 mm. A shielding block with a thickness of 20 cm will be equipped around the feeding waveguides to protect the feeding waveguides and to prevent neutron leakage. A preliminary scheme of the remote maintenance for the LFS launcher is given. The modeling results shows that the density for optimum coupling is ~ 1.8 × 10 17 /m 3 , lower than the 4.6 GHz cut-off density n e_co = 2.6 × 10 17 /m 3 . Around this density, the power directivity (D p ) can be high as 71%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inhibitor of apoptosis signal-regulating kinase 1 protects against acetaminophen-induced liver injury

Metabolic activation and oxidant stress are key events in the pathophysiology of acetaminophen (APAP) hepatotoxicity. The initial mitochondrial oxidative stress triggered by protein adduct formation is amplified by c-jun-N-terminal kinase (JNK), resulting in mitochondrial dysfunction and ultimately cell necrosis. Apoptosis signal-regulating kinase 1 (ASK1) is considered the link between oxidant stress and JNK activation. The objective of the current study was to assess the efficacy and mechanism of action of the small-molecule ASK1 inhibitor GS-459679 in a murine model of APAP hepatotoxicity. APAP (300 mg/kg) caused extensive glutathione depletion, JNK activation and translocation to the mitochondria, oxidant stress and liver injury as indicated by plasma ALT activities and area of necrosis over a 24 h observation period. Pretreatment with 30 mg/kg of GS-459679 almost completely prevented JNK activation, oxidant stress and injury without affecting the metabolic activation of APAP. To evaluate the therapeutic potential of GS-459679, mice were treated with APAP and then with the inhibitor. Given 1.5 h after APAP, GS-459679 was still protective, which was paralleled by reduced JNK activation and p-JNK translocation to mitochondria. However, GS-459679 treatment was not more effective than N-acetylcysteine, and the combination of GS-459679 and N-acetylcysteine exhibited similar efficacy as N-acetylcysteine monotherapy, suggesting that GS-459769 and N-acetylcysteine affect the same pathway. Importantly, inhibition of ASK1 did not impair liver regeneration as indicated by PCNA staining. In conclusion, the ASK1 inhibitor GS-459679 protected against APAP toxicity by attenuating JNK activation and oxidant stress in mice and may have therapeutic potential for APAP overdose patients. - Highlights: • Two ASK1 inhibitors protected against acetaminophen-induced liver injury. • The ASK1 inhibitors protect when used as pre- or post-treatment. • Protection by ASK1 inhibitor is not due to inhibition of APAP metabolism. • The ASK1 inhibitor prevents JNK activation and translocation to mitochondria. • Treatment with ASK1 inhibitors does not impair liver regeneration after APAP.

60 APPLIED LIFE SCIENCES↗

Electron-optical systems for planar gyrotrons

The methodology of designing an electron-optical system (EOS) that forms sheet helical electron beams (HEBs) for high-power gyrotrons is developed. As an example, we consider the EOS for a 140-GHz gyrotron operated at the first harmonic of the cyclotron frequency with an accelerating voltage of 50 kV, a beam current of 30 A, and a magnetic field compression of 36. A planar geometry of the magnetron-injection gun (MIG) is suggested. The adiabatic theory of MIGs modified for the planar geometry of EOS is used for preliminary estimations of MIG parameters. Numerical simulation of the HEB properties based on the CST STUDIO SUITE 3D code is performed to find the optimal configuration of a planar MIG. The accuracy of the calculated data is discussed. The main factors that affect the HEB quality are considered. It is shown that a sheet HEB with a pitch-factor of 1.3 and velocity spread not exceeding 25%–30% can be formed; this is quite acceptable for high-efficiency operation of modern gyrotrons. Calculation of the beam-wave interaction with the obtained HEB parameters proved that a high output power with a sufficiently good efficiency of about 20% can be reached. Simulations show the feasibility of the experimental implementation of a novel planar EOS and its use in short-wave planar gyrotrons. The developed technique can be used for the study and optimization of planar gyrotrons of different frequency bands and power levels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First operation of a multi-channel Q-Pix prototype: measuring transverse electron diffusion in a gas time projection chamber

We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH 4 ) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The Q-Pix method incorporates a precision switched integrating transimpedance amplifier whose output is compared to a threshold voltage. Upon reaching the threshold, a comparator sends a 'reset' signal, initiating a discharge of the integrating capacitor. The time difference between successive resets is inversely proportional to the average current at the pixel in that time interval, and the number of resets is directly proportional to the total collected charge. We developed a 16-channel Q-Pix prototype fabricated from commercial off-the-shelf components and coupled them to 16 concentric annular anode electrodes to measure the spatial extent of the electron swarm that reaches the anode after drifting through the uniform field of the TPC. The swarm is produced at a gold photocathode using pulsed UV light. The measured transverse diffusion agrees with simulations in PyBoltz across a range of operating pressures (200–1500 Torr). These results demonstrate that a Q-Pix readout can successfully reconstruct the ionization topology in a TPC.

47 OTHER INSTRUMENTATION↗

(Invited) Fuel Cell Component Durability for Million Mile Fuel Cell Trucks

While significant advances have been made and early commercial fuel cell light-duty vehicles (LDVs) are starting to be produced, fuel cells in the heavy-duty-vehicle (HDV) transportation sector (including trucks, long-haul semitrailers, maritime, trains, etc.) are nascent, despite the fact that advantages of fuel cells compared to both diesel and electric powertrains are very compelling in terms of emissions, charging time, efficiency, power-to-weight ratio, among others. However, the fuel-cell technology for HDVs requires a paradigm shift in fuel-cell research and development compared to LDVs, where the emphasis becomes efficiency and improvements in durability instead of a focus on increased power densities and lower cell costs. Heavy-duty applications require significantly longer vehicle lifetimes (>25,000 hours/1,000,000 miles for heavy-duty trucks), and therefore require improved fuel cell durability compared to light-duty vehicles. In 2020, HFTO formed the Million Mile Fuel Cell Truck Consortium (M2FCT) that includes a core team of five national laboratories to overcome durability and efficiency challenges in PEMFCs for heavy-duty applications with an initial focus on long-haul trucks. While targets and testing protocols have been developed for light-duty vehicles, the same level of targets and testing protocols have not been established for heavy-duty transportation. With operational times of greater than > 25,000 hours required, the need for well-developed accelerated stress tests (ASTs) is amplified. Results from these ASTs demonstrate the need for more durable electrode layers and well-controlled potential variations. Finally, this presentation will provide an overview of the DOE's Fuel Cell R&D approach, highlighting past and current activities, as well as strategies to enable fuel cell competiveness for heavy-duty applications.

25 ENERGY STORAGE↗

Measurement of Noise Produced by a Plasma Contactor Operating in Ground Based Facilities

Methods to measure electric field fluctuations accurately in a plasma with an active monopole antenna are described. It is shown that the conductive surfaces of the antenna must be adequately isolated from the ambient plasma and that the monopole must be sufficiently short to avoid antenna amplifier saturation. Experimental results illustrate that the noise produced by plasma contactor operation and sensed by the antenna is due to plasma phenomena and is not induced by laboratory power supplies. A good correlation is shown between the current fluctuations in the contactor electrical circuit and the noise detected by the antenna. A large body of experimental data support the conclusion that the majority of noise sensed by the antenna at frequencies less than 1 MHz is due to current fluctuations (electrostatic waves) in the plasma adjacent to the antenna and not to electromagnetic wave radiation. Caution is suggested when comparing antenna noise measurements to conventional specifications for radiated emissions.

Snyder, Steve↗

Acoustic wave propagation in uniform glow discharge plasma at an arbitrary angle between the electric field and wave vectors

This paper extends the recently reported one-dimensional model for sound propagation in glow discharge plasma to arbitrary mutual orientation of the plasma electric field and acoustic wave vectors. The results demonstrate that an acoustic wave in plasma may amplify, attenuate, or remain unchanged depending on the angle between these vectors and on the power input into the discharge. Quantitative evaluations indicate that for glow discharge plasma of a self-sustained discharge in air at the electric current densities of the order of 100 mA cm{sup -2}, a gain of as much as 1 m{sup -1} at 0 deg. angle between the vectors changes to similar strength attenuation for the 90 deg. angle.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectroscopic measurement of ion temperature and ion velocity distributions in the flux-coil generated FRC

One aim of the flux-coil generated field reversed configuration at Tri Alpha Energy (TAE) is to establish the plasma where the ion rotational energy is greater than the ion thermal energy. To verify this, an optical diagnostic was developed to simultaneously measure the Doppler velocity-shift and line-broadening using a 0.75 m, 1800 groves/mm, spectrometer. The output spectrum is magnified and imaged onto a 16-channel photomultiplier tube (PMT) array. The individual PMT outputs are coupled to high-gain, high-frequency, transimpedance amplifiers, providing fast-time response. The Doppler spectroscopy measurements, along with a survey spectrometer and photodiode-light detector, form a suite of diagnostics that provide insights into the time evolution of the plasma-ion distribution and current when accelerated by an azimuthal-electric field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microgan electron cyclotron resonance ion source in a Van de Graaff accelerator terminal

The Van de Graaff accelerator at IRMM works since many years providing proton, deuteron, and helium beams for nuclear data measurements. The original ion source was of RF type with quartz bottle. This kind of source, as well known, needs regular maintenance for which the accelerator tank must be completely opened. The heavy usage at high currents of the IRMM accelerator necessitated an opening about once every month. In 2010, the full permanent magnet Microgan electron cyclotron resonance (ECR) ion source from PANTECHNIK was installed into a new terminal platform together with a solid state amplifier of 50 W, a dedicated dosing system for 4 gases (with respective gas bottles H{sub 2}, D{sub 2}, He, and Ar), and a set of dedicated power supplies and electronic devices for the remote tuning of the source. The new system shows a very stable behaviour of the produced beam allowing running the Van de Graaf without maintenance for several months. This contribution will describe the full installed system in details (working at high pressure in the terminal, spark effects, and optic of the extraction), as well as beam results in dc or pulsed mode.

43 PARTICLE ACCELERATORS↗

INDUCED MAXIMUM MAGNETIC FIELD IN COSMIC OUTFLOW SYSTEM BY A RELATIVISTIC CURRENT FILAMENTATION INSTABILITY: EXACT ANALYTICAL MODEL

We present an analytical study of current filamentation instability (CFI) in a fully relativistic cold plasma system, including arbitrary currents. For our purposes, we employ the cold fluid equations, together with Maxwell's equations as well as the plasma shell concept and boost frame method, to obtain an exact solution of the instability growth rate. A simple relation is found for the maximum growth rate of the CFI (for any arbitrary current system), which remarkably is used to calculate the large magnitude of an induced magnetic field in astrophysical environments such as active galactic nuclei (AGNs), microquasars, supernova remnants (SNRs), and stellar winds. We find that the magnetic field is amplified in the SNR up to the level required to justify the recent discovery of the year-scale variability in the X-ray emission of SNRs. Also, the maximum magnetic field of two and three orders higher (or two orders lower) than that of the SNR has been derived for microquasars and AGNs (or stellar winds), respectively. Moreover, making use of the exact analytical solution of the CFI, it is shown that the maximum magnetic field up to around 10{sup 8} G can be detected from a classical cold counterstreaming system after a saturation time.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermometric- and Acoustic-Based Beam Power Monitor for Ultra-Bright X-Rays

A design for an average beam power monitor for ultra-bright X-ray sources is proposed that makes simultaneous use of calorimetry and radiation acoustics. Radiation incident on a solid target will induce heating and ultrasonic vibrations, both of which may be measured to give a fairly precise value of the beam power. The monitor is intended for measuring ultra-bright Free-Electron Laser (FEL) X-ray beams, for which traditional monitoring technologies such as photo-diodes or scintillators are unsuitable. The monitor consists of a Boron Carbide (B{sub 4}C) target designed to absorb most of the incident beam's energy. Resistance temperature detectors (RTD) and piezoelectric actuators are mounted on the outward faces of the target to measure the temperature changes and ultrasonic vibrations induced by the incident beam. The design was tested using an optical pulsed beam (780 nm, 120 and 360 Hz) from a Ti:sapphire oscillator at several energies between 0.8 and 2.6 mJ. The RTDs measured an increase in temperature of about 10 K over a period of several minutes. The piezoelectric sensors recorded ringing acoustic oscillations at 580 {+-} 40 kHz. Most importantly, the amplitude of the acoustic signals was observed to scale linearly with beam power up to 2 mJ of pulse energy. Above this pulse energy, the vibrational signals became nonlinear. Several causes for this nonlinearity are discussed, including amplifier saturation and piezoelectric saturation. Despite this nonlinearity, these measurements demonstrate the feasibility of such a beam power measurement device. The advantage of two distinct measurements (acoustic and thermometric) provides a useful method of calibration that is unavailable to current LCLS diagnostics tools.

Bentsen, Gregory↗

Weakly Magnetized, Hall Dominated Plasma Couette Flow

A novel plasma equilibrium in the high-β, Hall regime that produces centrally-peaked, high Mach number Couette flow is described. Flow is driven using a weak, uniform magnetic field and large, cross field currents. Large magnetic field amplification (factor 20) due to the Hall effect is observed when electrons are flowing radially inward, and near perfect field expulsion is observed when the flow is reversed. A dynamic equilibrium is reached between the amplified (removed) field and extended density gradients.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reliability study of refractory gate gallium arsenide MESFETS

Refractory gate MESFET's were fabricated as an alternative to aluminum gate devices, which have been found to be unreliable as RF power amplifiers. In order to determine the reliability of the new structures, statistics of failure and information about mechanisms of failure in refractory gate MESFET's are given. Test transistors were stressed under conditions of high temperature and forward gate current to enhance failure. Results of work at 150 C and 275 C are reported.

Yin, J. C. W.↗

Virology: The Next Generation from Digital PCR to Single Virion Genomics

In the past 25 years, virology has had major technology breakthroughs stemming first from the introduction of nucleic acid amplification testing, but more recently from the use of next-generation sequencing, digital PCR, and the possibility of single virion genomics. These technologies have and will improve diagnosis and disease state monitoring in clinical settings, aid in environmental monitoring, and reveal the vast genetic potential of viruses. Using the principle of limiting dilution, digital PCR amplifies single molecules of DNA in highly partitioned endpoint reactions and reads each of those reactions as either positive or negative based on the presence or absence of target fluorophore. In this review, digital PCR will be highlighted along with current studies, advantages/disadvantages, and future perspectives with regard to digital PCR, viral load testing, and the possibility of single virion genomics.

59 BASIC BIOLOGICAL SCIENCES↗