Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Multiscale porosity characterization in additively manufactured polymer nanocomposites using micro-computed tomography

Extrusion-based additive manufacturing (AM) of polymer composites exhibits complex thermally driven phenomena that introduce severe discontinuities in the internal structure across length scales, especially voids or porosity. This study utilizes a high-throughput porosity characterization technique to analyze large datasets from numerous micro-computed tomography (mu CT) scans to capture the influence of AM print parameters on the size, shape, and location of porosity across multiple print layers (up to a few cm) on fused granular fabrication (FGF) printers. The materials investigated include nanocomposite formulations based on commercially relevant nylon-12 and polyether ketone ketone (PEKK) materials comprising nano- or micro- sized fillers. The estimated global porosity follows an inverse linear correlation against the bulk density of the printed samples. Increasing the extrusion multiplier (EM) and the nozzle temperature while decreasing the print speeds reduces the global porosity. Outlier analyses (local porosity morphology) show that faster print speeds and higher extrusion rates result in long, slender inter-layer voids, while lower nozzle temperatures lead to large, symmetrical, inter-bead voids (at the bead junction). Lack of active chamber temperature increases inter-layer and intra-bead voids with a two-fold increase in global porosity. Overall, the micro filler-reinforced composites exhibit higher global porosity than nanofiller-reinforced composites, which is attributed to the increased mismatch in the thermal expansion coefficient between the filler and the polymers used in the study.

36 MATERIALS SCIENCE↗

The role of the spatial heterogeneity and correlation length of surface wettability on two-phase flow in a CO 2 -water-rock system

This study characterized and modeled heterogeneous surface wettability in sandstone and investigated the role of spatial heterogeneity and correlation length of surface wettability on relative permeability in a supercritical CO 2 (scCO 2 )-brine-rock system. Understanding the role of wettability heterogeneity on relative permeability is essential to geological CO 2 sequestration, oil and gas recovery, and contaminated groundwater remediation. Although numerous studies have attempted to understand the influences of surface wettability, capillary number (Ca), and viscosity ratio, the role of the spatial variation and correlation length of surface wettability on two-phase flow in three-dimensional (3D) porous media has not been unraveled due to the challenges in the measurement and representation of realistic rock surface wettability. In this work, we conducted in-situ measurements of surface contact angle (CA) in a Bentheimer sandstone after CO 2 flooding using micro-computed tomography (micro-CT), and found that the pore-scale CA distribution on rock surfaces followed a log-normal distribution associated with a spatial correlation length. Based on the statistical information from CT scanning, a Gaussian random field was used to model CA distributions that had desired standard deviations and spatial correlation lengths, which were then adjusted within a certain range of values for sensitivity analyses to study their combined effects on the two-phase flow in the porous medium using the lattice Boltzmann (LB) method. The LB two-phase flow simulation was accelerated using hybrid, multicore parallel computing to overcome the challenges in simulating multiphase flow in a large 3D domain having 800 × 800 × 600 nodes. The simulation results showed that the surface wettability heterogeneity (i.e., standard deviation of CA) had a lesser effect on the relative permeability of the wetting fluid (water) but a more significant impact on the relative permeability of the non-wetting fluid (scCO 2 ). The Corey model was used to fit the LB-simulated relative permeability curves of water and scCO 2 and showed that the variations in the relative permeability curves for both water and scCO 2 increased as the standard deviation and spatial correlation length of CA increased. This study illustrated that the assumption of homogeneous surface wettability may cause errors in multiphase flow simulations. Furthermore, the impacts of both the standard deviation and spatial correlation length of CAs should be accounted for. This is the first study that explored the spatial correlation lengths associated with CA distributions on sandstone surfaces and comprehensively investigated the roles of both spatial variation and correlation length of CA on two-phase flow properties in 3D porous media. The optimized LB multiphase flow model was proved a powerful tool to study the interplays and combined effects of these statistical parameters, which had critical applications in numerous natural and engineering processes that involved multiphase flow in porous media.

58 GEOSCIENCES↗

Tenuigenin inhibits RANKL-induced osteoclastogenesis by down-regulating NF-κB activation and suppresses bone loss in vivo

Tenuigenin, a major active component of polygala tenuifolia root, has been used to treat patients with insomnia, dementia, and neurosis. In this study, we aimed to investigate the effects of tenuigenin on osteoclastogenesis and clarify the possible mechanism. We showed that tenuigenin inhibited receptor activator of nuclear factor-κB ligand (RANKL)-induced osteoclast differentiation and bone resorption without cytotoxicity, which was further demonstrated by reduced osteoclast specific gene expression such as TRAP, c-Src, ATP6v0d2, etc. Moreover, the inhibitory effect of tenuigenin was associated with impaired NF-κB activity owing to delayed degradation/regeneration of IkBa and inhibition of p65 nuclear translocation. Consistent with the in vitro results, micro-ct scanning and analysis data showed that tenuigenin suppressed RANKL-induced bone loss in an animal model. Taken together, our data demonstrate that tenuigenin inhibit osteoclast formation and bone resorption both in vitro and in vivo, and comprise a potential therapeutic alternative for osteoclast-related disorders such as osteoporosis and cancer-induced bone destruction. - Highlights: • Tenuigenin suppresses osteoclasts formation, survival and function in vitro. • Tenuigenin impairs NF-κB activation. • Tenuigenin suppresses RANKL-induced bone lose in vivo. • Tenuigenin may be used for treating osteoclast related diseases.

60 APPLIED LIFE SCIENCES↗

Depleting the carboxy-terminus of human Wnt5a attenuates collagen-induced arthritis in DBA/1 mice

Highlights: • phWnt5a-NL recombinant results in decreased severity of CII-induced arthritis. • phWnt5a-NL recombinant suppresses synovitis and osteoclastogenesis. • phWnt5a-NL recombinant induces the production of Treg cells. • phWnt5a-NL recombinant interrupts the Wnt5a-Ror2 signalling pathway. Wnt5a signalling plays pathological roles in synovial inflammation and bone destruction. In the present study, we designed four human Wnt5a-based DNA recombinants and detected their effects on immunogenicity and anti-rheumatism in a collagen-induced arthritis (CIA) model. Histomorphometry and micro-CT scanning showed that the phWnt5a-NL was superior to other recombinants because it resulted in decreased severity of arthritis, histopathological scores of synovial inflammation and bone erosion in CIA mice. In addition, ELISA and TRAP staining showed that the phWnt5a-NL-immunized CIA mice had reductions in the serum concentrations of the rheumatoid-associated cytokines IL-1β and RANKL and in osteoclastogenesis. Furthermore, flow cytometry showed that the phWnt5a-NL treatment increased the percentage of Treg cells. Finally, western blotting analysis showed that the phWnt5a-NL-immunization interrupted β-catenin and JNK expression in osteoclast precursors derived from the CIA mice. The results suggest that depleting the carboxy-terminus in hWnt5a-based DNA recombinants may be beneficial for the treatment of chronic inflammatory disorders involving bone resorption.

60 APPLIED LIFE SCIENCES↗

Combined treatment with cinnamaldehyde and PTH enhances the therapeutic effect on glucocorticoid-induced osteoporosis through inhibiting osteoclastogenesis and promoting osteoblastogenesis

Highlights: • Administration with cinnamaldehyde and PTH together promoted bone formation compared with monotherapy in GIO rats. • Administration with cinnamaldehyde and PTH together promoted the expression of runx2 compared with monotherapy in GIO rats. • Administration with cinnamaldehyde and PTH together inhibited the expression of trap compared with monotherapy in GIO rats. • Administration with cinnamaldehyde and PTH together promoted the expression of ALP in vitro compared with monotherapy. The study was to investigate the effect of combining treatment with cinnamaldehyde and parathyroid hormone (1−34) (PTH) on glucocorticoid-induced osteoporosis (GIO) and compare with monotherapy. Forty Sprague-Dawley male rats with GIO were divided into four groups randomly: control group (CON group, N = 10); group that intragastric administration with cinnamaldehyde (CIN group, N = 10); group that subcutaneous injection with PTH, three times per week(PTH group, N = 10); both administration with cinnamaldehyde and PTH (CIN + PTH group, N = 10). Distal femurs were harvested for hematoxylin and eosin (H&E) staining, micro-CT scanning and immunohistochemical analysis. Murine mesenchymal stem cells were cultured and dealt with the presence of dexamethasone(DEX group), DEX + cinnamaldehyde(DEX + CIN group), DEX + PTH(DEX + PTH group) or DEX + cinnamaldehyde + PTH(DEX + CIN + PTH group). Alkaline phosphatase (ALP) staining was performed subsequently. The results showed that bone formation in CIN + PTH group was notably promoted compared with other groups. And the expression of tartrate-resistant acid phosphatase (trap) and runt-related transcription factor 2 (runx2) in CIN + PTH group were down-regulated and up-regulated respectively compared with PTH group. In vitro study revealed that ALP-positive cell number in DEX + CIN + PTH group was obviously enhanced compared with other groups. The study revealed that combined treatment with cinnamaldehyde and PTH enhances the therapeutic effect on GIO through inhibiting osteoclastogenesis and promoting osteoblastogenesis.

60 APPLIED LIFE SCIENCES↗

Finite elements for Matérn-type random fields: Uncertainty in computational mechanics and design optimization

This work highlights an approach for incorporating realistic uncertainties into scientific computing workflows based on finite elements, focusing on prevalent applications in computational mechanics and design optimization. We leverage Matérn-type Gaussian random fields (GRFs) generated using the SPDE method to model aleatoric uncertainties, including environmental influences, variating material properties, and geometric ambiguities. Our focus lies on delivering practical GRF realizations that accurately capture imperfections and variations and understanding how they impact the predictions of computational models as well as the shape and topology of optimized designs. Here we describe a numerical algorithm based on solving a generalized SPDE to sample GRFs on arbitrary meshed domains. The algorithm leverages established techniques and integrates seamlessly with the open-source finite element library MFEM and associated scientific computing workflows, like those found in industrial and national laboratory settings. Our solver scales efficiently for large-scale problems and supports various domain types, including surfaces and embedded manifolds. We showcase its versatility through biomechanics and topology optimization applications, emphasizing the potential to influence these domains. The flexibility and efficiency of SPDE-based GRF generation empowers us to run large-scale optimization problems on 2D and 3D domains, including finding optimized designs on embedded surfaces, and to generate design features and topologies beyond the reach of conventional techniques. Moreover, these capabilities allow us to model and quantify geometric uncertainties on reconstructed submanifolds, such as the interpolated surfaces of cerebral aneurysms provided by postprocessing CT scans. In addition to offering benefits in these specific domains, the proposed techniques transcend specific applications and generalize to arbitrary forward and backward problems in uncertainty quantification involving finite elements.

97 MATHEMATICS AND COMPUTING↗

Influence of carbon dioxide on coal permeability determined by pressure transient methods

The permeability of coal samples from Pittsburgh Seam was determined using carbon dioxide as the flowing fluid. The confining pressure was varied to cover a wide range of depths. The permeability was determined as a function of exposure time of carbon dioxide while the confining stress was kept constant. The porosities of the coal samples were found to be very low and most of the samples had porosities less than 1%. The permeability of these coal samples was very low-less than 1μD. Since the objective of this study was to investigate the influence of CO 2 exposure on coal permeability, it was necessary to increase the initial permeability of the coal samples by introducing a fracture. A longitudinal fracture was induced mechanically, and CT scans were taken to ensure that the fracture was present throughout the sample and that the sample was not damaged otherwise during the process. In this study, the permeability of coal was determined by using pressure transient methods. Two types of pressure pulses were used: A-spike and Sine-6 pressure transients. It was first established that the permeability of fractured coal samples did not change with exposure time when an inert gas (Argon) was used as the fluid medium in the experiments. However, the permeability of coal samples decreased significantly when carbon dioxide was used as the fluid medium. This reduction can be attributed to the coal swelling phenomenon. The results show that the permeability reduction in fractured coal samples can be over 90% of the original value, and the exposure time for such reductions can range from 1.5 days up to a week, typically about 2 days under laboratory conditions. The permeability decreased significantly with the increase in confining pressure. The higher confining pressure appears to close internal fractures causing a reduction in permeability.

01 COAL, LIGNITE, AND PEAT↗

Geochemical and geomechanical alteration of siliciclastic reservoir rock by supercritical CO 2 -saturated brine formed during geological carbon sequestration

Geologic carbon sequestration (GCS) is a method for storing CO 2 and mitigating greenhouse gas emissions. During GCS, carbon dioxide dissolves into pore water, resulting in a low-pH brine that can react with reservoir rock minerals. This work evaluates the effects of geochemical reactions on geomechanical integrity of representative siliciclastic reservoir samples obtained from the Mt. Simon formation. Rock samples were aged 4 or 8 weeks in CO 2 -saturated brine under reservoir conditions, and in N 2 -saturated brine as a control. Post-aging, CT scans revealed more extensive micro-fracture development along horizontal bedding planes at grain edges in CO 2 versus N 2 -aged samples. Digital analysis of CO 2 -aged samples showed porosity increase from 8.1% to 15.8%. Scanning electron microscopy unearthed the loss of clay cementation, greater exposure of quartz and K-feldspar grains, and apparent surface roughening (confirmed by laser profilometry) in CO 2 -aged samples, but not in N 2 -aged samples. Fracture toughness as evaluated by scratch testing was reduced by 32.1% after 4 weeks in scCO 2 -saturated brine and 69.5% after 8 weeks. The main reason for weakening appears to be detachment of clays from quartz and feldspar grain surfaces, resulting in weakening of the rock matrix. Rock weakening may alter the geomechanical stability of storage formations.

58 GEOSCIENCES↗

Implantation and Stability of Metallic Fiducials Within Pulmonary Lesions

Purpose: To report and describe implantation techniques and stability of metallic fiducials in lung lesions to be treated with external beam radiotherapy. Methods and Materials: Patients undergoing radiation therapy for small early-stage lung cancer underwent implantation with small metallic markers. Implantation was either transcutaneous under computed tomographic (CT) or fluoroscopic guidance or transbronchial with the superDimension/Bronchus system (radiofrequency signal-based bronchoscopy guidance related to CT images). Results: Implantation was performed transcutaneously in 15 patients and transbronchially in 8 patients. Pneumothorax occurred with eight of the 15 transcutaneous implants, six of which required chest tube placement. None of the patients who underwent transbronchial implantation developed pneumothorax. Successfully inserted markers were all usable during gated image-guided radiotherapy. Marker stability was determined by observing the variation in gross target volume (GTV) centroid relative to the marker on repeated CT scans. Average three-dimensional variation in the GTV center relative to the marker was 2.6 {+-} 1.3 (SD) mm, and the largest variation along any anatomic axis for any patient was <5 mm. Average GTV volume decrease during the observation period was 34% {+-} 23%. Gross tumor volumes do not appear to shrink uniformly about the center of the tumor, but rather the tumor shapes deform substantially throughout treatment. Conclusions: Transbronchial marker placement is less invasive than transcutaneous placement, which is associated with high pneumothorax rates. Although marker geometry can be affected by tumor shrinkage, implanted markers are stable within tumors throughout the treatment duration regardless of implantation method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Four-Dimensional CT-Based Evaluation of Techniques for Gastric Irradiation

Purpose: To evaluate three-dimensional conformal (3D-CRT), intensity-modulated (IMRT) and respiration-gated radiotherapy (RGRT) techniques for gastric irradiation for target coverage and minimization of renal doses. All techniques were four-dimensional (4D)-CT based, incorporating the intrafractional mobility of the target volume and organs at risk (OAR). Methods and Materials: The stomach, duodenal C-loop, and OAR (kidneys, liver, and heart) were contoured in all 10 phases of planning 4D-CT scans for five patients who underwent abdominal radiotherapy. Planning target volumes (PTVs) encompassing all positions of the stomach (PTV{sub allphases}) were generated. Three respiratory phases for RGRT in inspiration and expiration were identified, and corresponding PTV{sub inspiration} and PTV{sub expiration} and OAR volumes were created. Landmark-based fields recommended for the Radiation Therapy Oncology Group (RTOG) 99-04 study protocol were simulated to assess PTV coverage. IMRT and 3D-CRT planning with and without additional RGRT planning were performed for all PTVs, and corresponding dose volume histograms were analyzed. Results: Use of landmark-based fields did not result in full geometric coverage of the PTV{sub allphases} in any patient. IMRT significantly reduced mean renal doses compared with 3D-CRT (15.0 Gy {+-} 0.9 Gy vs. 20.1 Gy {+-} 9.3 Gy and 16.6 Gy {+-} 1.5 Gy vs. 32.6 Gy {+-} 7.1 Gy for the left and right kidneys, respectively; p = 0.04). No significant increase in renal sparing was seen when adding RGRT to either 3D-CRT or IMRT. Tolerance doses to the other OAR were not exceeded. Conclusions: Individualized field margins are essential for gastric irradiation. IMRT plans significantly reduce renal doses, but the benefits of RGRT in gastric irradiation appear to be limited.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Image Guidance on Outcomes After External Beam Radiotherapy for Localized Prostate Cancer

Purpose: To verify whether rectal distention at the time of planning impacts outcomes in patients with localized prostate cancer treated with daily image guidance. Methods and Materials: Between 1998 and 2002, a total of 488 prostate cancer patients were treated with intensity-modulated radiotherapy. The radiation dose was 70 Gy delivered at 2.5 Gy per fraction in all cases. All cases were treated with a 4-mm margin posteriorly. In all cases the total rectal volume documented on the CT scan was used for treatment planning. No special bowel preparation instructions were given, either for the simulation or the daily treatments. Before each daily treatment, alignment of the prostate was performed with the B-mode acquisition and targeting (BAT) transabdominal ultrasound system. The median follow-up for all 488 patients was 60 months (range, 24-96 months). Results: For all patients the biochemical relapse-free survival (bRFS) rate at 5 years was 86%. The 5-year bRFS rate for the rectal distention <50 cm{sup 3}, 50 to <100 cm{sup 3}, and {>=}100 cm{sup 3} groups was 90%, 83%, and 85%, respectively (p = 0.18). To adjust for other potential variables affecting bRFS rates, a multivariate time-to-failure analysis using the Cox proportional hazards model was performed. Rectal distention was not an independent predictor of biochemical failure on multivariate analysis (p = 0.80). Rectal distention was not a predictor of rectal or urinary toxicity. Conclusion: The use of daily image guidance eliminates errors such as rectal distention at the initial planning stage that can affect outcomes after radiotherapy for localized prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of Intensity-Modulated Radiotherapy on Radiation-Induced Second Malignancies

Purpose: To compare intensity-modulated radiotherapy (IMRT) with three-dimensional conformal radiotherapy (3D-CRT) in terms of carcinogenic risk for actual clinical scenarios. Method and Materials: Clinically equivalent IMRT plans were generated for prostate, breast, and head-and-neck cases treated with 3D-CRT. Two possible dose-response models for radiocarcinogenesis were generated based on A-bomb survivor data corrected for fractionation. Dose-volume histogram analysis was used to determine dose and its distribution to nontargeted tissues within the planning CT scan volume and thermoluminescent dosimetry for the rest of the body. Carcinogenic estimates were calculated with and without a correction factor accounting for cancer patients' advanced age and reduced longevity. Results: For the model assuming a plateau in risk above 2-Gy single-fraction-equivalent (SFE), IMRT and 3D-CRT produced risks of 1.7% and 2.1%, respectively, for prostate; 1.9% and 1.8%, respectively, for nasopharynx; 1% each for tonsil; and 1.4-2.2% and 1.5-1.6%, respectively, depending on technique, for breast. Assuming a reduction in risk above 2-Gy SFE, risks for IMRT and 3D-CRT were 1.1% and 1.5%, respectively, for prostate; 1.4% and 1.2%, respectively, for nasopharynx; 1% each for tonsil; and 1.3-1.8% vs. 1.3-1.6%, respectively, for breast. Applying a correction factor of 0.5 for cancer patients halved these risks and their relative differences. Conclusions: Carcinogenic risks were comparable in absolute terms between modalities. Risks are dependant on technique used. Risks with IMRT are influenced by monitor unit demand and are therefore software/hardware dependant. The dose-response model accounting for cell killing at higher doses fitted best with actual observed risks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Dimensional Image Registration for Image-Guided Radiotherapy

Purpose: Newly emerged four-dimensional (4D) imaging techniques such as 4D-computed tomography (CT), 4D-cone beam CT, 4D-magnetic resonance imaging, and 4D-positron emission tomography are effective tools to reveal the spatiotemporal details of patients' anatomy. To use the 4D data acquired under different conditions or using different modalities, an algorithm for registering 4D images must be in place. We developed an automated 4D-4D registration method to take advantage of 4D information. Methods and Materials: We used 4D-4D matching to find the appropriate three-dimensional anatomy in the fixed image for each phase of the moving image and spatially register them. A search algorithm was implemented to simultaneously find the best phase and spatial match of two 4D inputs. An interpolation scheme capable of deriving an image set based on temporally adjacent three-dimensional data sets was developed to deal with the situation in which the discrete temporal points of the two inputs do not coincide or correspond. Results: In a phantom study, our technique was able to reproduce the known 'ground truth' with high spatial fidelity. The technique regenerated all deliberately introduced 'missing' three-dimensional images at different phases of the input using temporal interpolation. In the registration of gated-magnetic resonance imaging and 4D-CT, the algorithm was able to select the appropriate CT phase. The technique was also able to register 4D-CT with 4D-cone beam CT and two 4D-CT scans acquired at different times. A spatial accuracy of <3 mm was achieved in 98% of voxels in all cases. Conclusion: Automated 4D-4D registration can find the best possible spatiotemporal match between two 4D data sets and is useful for image-guided radiotherapy applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Multiple Breathing States Using a Multiple Instance Geometry Approximation (MIGA) in Inverse-Planned Optimization for Locoregional Breast Treatment

Purpose: Although previous work demonstrated superior dose distributions for left-sided breast cancer patients planned for intensity-modulated radiation therapy (IMRT) at deep inspiration breath hold compared with conventional techniques with free-breathing, such techniques are not always feasible to limit the impact of respiration on treatment delivery. This study assessed whether optimization based on multiple instance geometry approximation (MIGA) could derive an IMRT plan that is less sensitive to known respiratory motions. Methods and Materials: CT scans were acquired with an active breathing control device at multiple breath-hold states. Three inverse optimized plans were generated for eight left-sided breast cancer patients: one static IMRT plan optimized at end exhale, two (MIGA) plans based on a MIGA representation of normal breathing, and a MIGA representation of deep breathing, respectively. Breast and nodal targets were prescribed 52.2 Gy, and a simultaneous tumor bed boost was prescribed 60 Gy. Results: With normal breathing, doses to the targets, heart, and left anterior descending (LAD) artery were equivalent whether optimizing with MIGA or on a static data set. When simulating motion due to deep breathing, optimization with MIGA appears to yield superior tumor-bed coverage, decreased LAD mean dose, and maximum heart and LAD dose compared with optimization on a static representation. Conclusions: For left-sided breast-cancer patients, inverse-based optimization accounting for motion due to normal breathing may be similar to optimization on a static data set. However, some patients may benefit from accounting for deep breathing with MIGA with improvements in tumor-bed coverage and dose to critical structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calcifications Are Potential Surrogates for Prostate Localization in Image-Guided Radiotherapy

Purpose: To investigate the feasibility of using calcifications as surrogates for the prostate position during cone-beam computed tomography (CBCT) image-guided radiotherapy. Methods and Materials: The twice-weekly CBCT images taken during the treatment course of 4 patients were retrospectively studied for the stability of the calcifications. The geometric center of three fiducial markers was used as the reference. The planning CT images of 131 prostate patients recently treated with external beam radiotherapy at our center were reviewed to estimate the calcification occurrence rate. Analysis was conducted using the Varian Eclipse treatment planning system. Two patients were treated using prostate calcifications as the landmark in on-line registration. Both the Varian standard and the low-dose CBCT modes were used for imaging. Results: The calcifications were found to be stable during the treatment course. At the 95% confidence interval, the difference between the distance from an identified calcification to the fiducial markers on CBCT and the distance on the planning CT scans was 0.2 {+-} 2.0 mm, 0.8 {+-} 2.2 mm, and 0.4 {+-} 2.4 mm in the left-right, anteroposterior, and superoinferior direction, respectively. Of the 131 patients, 46 (35%) had well-defined calcifications either inside the prostate or near the borders. Our experience in treating the first 2 patients demonstrated that the calcifications are easily distinguished on low-dose scans and that calcification registration can be precisely performed. Conclusion: The results of our study have shown that calcifications can be reliable markers of prostate position and allow for precise image guidance with a low-imaging dose. With this approach, potentially about one-third of prostate patients could benefit from precise image guidance without the invasive use of markers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Dosimetric Parameters and Disease Response After {sup 125}Iodine Transperineal Brachytherapy for Low- and Intermediate-Risk Prostate Cancer

Purpose: To analyze dosimetric outcomes after permanent brachytherapy for men with low-risk and 'low-tier' intermediate-risk prostate cancer and explore the relationship between the traditional dosimetric values, V100 (volume of prostate receiving 100% of the prescribed dose) and D90 (minimum dose to 90% of the prostate), and risk of biochemical failure. Methods and Materials: A total of 1,006 consecutive patients underwent implantation between July 20, 1998, and Oct 23, 2003. Most (58%) had low-risk disease; the remaining 42% comprised a selected low-tier subgroup of intermediate-risk patients. The prescribed minimum peripheral dose (MPD) was 144 Gy. All implants used 0.33 mCi {sup 125}I sources using a preplan technique featuring right-left symmetry and a strong posterior-peripheral dose bias. Sixty-five percent of patients had 6 months of androgen deprivation therapy. Postimplantation dosimetry was calculated using day-28 CT scans. Results: With a median follow-up of 54 months, the actuarial 5-year rate of freedom from biochemical recurrence (bNED) was 95.6% {+-} 1.6%. Median D90 was 105% of MPD, median V100 was 92%, median V150 was 58%, and median V200 was 9%. Dosimetric values were not predictive of biochemical recurrence on univariate or multivariate analysis. Analysis of dosimetric values by implantation number showed statistically significant increases in all values with time (D90, V100, V150, and V200; p < 0.001), but this did not translate into improved bNED. Conclusions: In contrast to some previous studies, dosimetric outcomes did not correlate with biochemical recurrence in the first 1,006 patients treated with {sup 125}I prostate brachytherapy at the British Columbia Cancer Agency. Despite a median D90 of only 105% of MPD, our bNED rates are indistinguishable from series that reported higher D90 values.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential for Higher Treatment Failure in Obese Patients: Correlation of Elevated Body Mass Index and Increased Daily Prostate Deviations From the Radiation Beam Isocenters in an Analysis of 1,465 Computed Tomographic Images

Purpose: Recent clinical outcome studies on prostate cancer have reported the influence of patient's obesity on the biochemical failure rates after various treatment modalities. In this study, we investigated the effect of patient's physical characteristics on prostate shift in external beam radiotherapy (EBRT) and hypothesized that there maybe a correlation between patient physique and tumor shift. Methods and Materials: A retrospective analysis was performed using data for 117 patients who received image-guided radiation therapy (IGRT) for prostate cancer between January 2005 and April 2007. A total of 1,465 CT scans were analyzed. The standard deviations (SDs) of prostate shifts for all patients, along with patient weight, body mass index (BMI), and subcutaneous adipose-tissue thickness (SAT), were determined. Spearman rank correlation analysis was performed. Results: Of the 117 patients, 26.5% were considered normal weight, 48.7% were overweight, 17.9% were mildly obese, and 6.9% were moderately to severely obese. Notably 1.3%, 1.5%, 2.0%, and 21.2% of the respective shifts were greater than 10 mm in the left-right (LR) direction for the four patient groups, whereas in the anterior-posterior direction the shifts are 18.2%, 12.6%, 6.7%, and 21.0%, respectively. Strong correlations were observed between SAT, BMI, patient weight, and SDs of daily shifts in the LR direction (p < 0.01). Conclusions: The strong correlation between obesity and shift indicates that without image-guided radiation therapy, the target volume (prostate with or without seminal vesicles) may not receive the intended dose for patients who are moderate to severely obese. This may explain the higher recurrence rate with conventional external beam radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Vivo Dosimetry Using a Linear Mosfet-Array Dosimeter to Determine the Urethra Dose In {sup 125}I Permanent Prostate Implants

Purpose: In vivo dosimetry during brachytherapy of the prostate with {sup 125}I seeds is challenging because of the high dose gradients and low photon energies involved. We present the results of a study using metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to evaluate the dose in the urethra after a permanent prostate implantation procedure. Methods and Materials: Phantom measurements were made to validate the measurement technique, determine the measurement accuracy, and define action levels for clinical measurements. Patient measurements were performed with a MOSFET array in the urinary catheter immediately after the implantation procedure. A CT scan was performed, and dose values, calculated by the treatment planning system, were compared to in vivo dose values measured with MOSFET dosimeters. Results: Corrections for temperature dependence of the MOSFET array response and photon attenuation in the catheter on the in vivo dose values are necessary. The overall uncertainty in the measurement procedure, determined in a simulation experiment, is 8.0% (1 SD). In vivo dose values were obtained for 17 patients. In the high-dose region (> 100 Gy), calculated and measured dose values agreed within 1.7% {+-} 10.7% (1 SD). In the low-dose region outside the prostate (< 100 Gy), larger deviations occurred. Conclusions: MOSFET detectors are suitable for in vivo dosimetry during {sup 125}I brachytherapy of prostate cancer. An action level of {+-} 16% (2 SD) for detection of errors in the implantation procedure is achievable after validation of the detector system and measurement conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗