Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BERYLLIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Body burden of toxic metals and rare earth elements in non-smokers, cigarette smokers and electronic cigarette users

Highlights: • The role of smoking as a source for 42 inorganic element intakes was explored. • The exposure levels of non-smoker, cigarette smokers and e-cigarette users was compared. • Cigarette smokers showed the highest levels of Cu, Mo, Zn, Sb, and Sr. • E-cigarettes users presented the highest concentrations of Se, Ag, and V. • Be, Eu and La were detected more frequently among e-cigarette users. Smoking is considered an important source for inorganic elements, most of them toxic for human health. During the last years, there has been a significant increase in the use of e-cigarettes, although the role of them as source of inorganic elements has not been well established. A cross-sectional study including a total of 150 subjects from Brasov (Romania), divided into three groups (non-smokers, cigarette smokers and electronic cigarettes smokers) were recruited to disclose the role of smoking on the human exposure to inorganic elements. Concentration of 42 elements, including trace elements, elements in the ATSDR's priority pollutant list and rare earth elements (REE) were measured by ICP-MS in the blood serum of participants. Cigarette smokers showed the highest levels of copper, molybdenum, zinc, antimony, and strontium. Electronic cigarette (e-cigarette) users presented the highest concentrations of selenium, silver, and vanadium. Beryllium, europium and lanthanides were detected more frequently among e-cigarette users (20.6%, 23.5%, and 14.7%) than in cigarette smokers (1.7%, 19.0%, and 12.1%, respectively); and the number of detected REE was also higher among e-cigarette users (11.8% of them showed more than 10 different elements). Serum levels of cerium and erbium increased as the duration of the use of e-cigarettes was longer. We have found that smoking is mainly a source of heavy metals while the use of e-cigarettes is a potential source of REE. However, these elements were detected at low concentrations.

54 ENVIRONMENTAL SCIENCES↗

Overview of the US-Japan collaborative investigation on hydrogen isotope retention in neutron-irradiated and ion-damaged tungsten

Plasma-facing components (PFCs) will be exposed to 14 MeV neutrons from deuterium-tritium (D-T) fusion reactions, and tungsten, a candidate PFC for the divertor in ITER, is expected to receive a neutron dose of 0.7 displacement per atom (dpa) by the end of operation in ITER. The effect of neutron-irradiation damage has been mainly simulated using high-energy ion bombardment. While this prior database of results is quite valuable for understanding the behavior of hydrogen isotopes in PFCs, it does not encompass the full range of effects that must be considered in a practical fusion environment due to short penetration depth, damage gradient, high damage rate, and high PKA energy spectrum of the ion bombardment. In addition, neutrons change the elemental composition via transmutations, and create a high radiation environment inside PFCs, which influence the behavior of hydrogen isotope in PFCs, suggesting the utilization of fission reactors is necessary for neutron irradiation. Therefore, the effort to correlate among high-energy ions, fission neutrons, and fusion neutrons is crucial for accurately estimating tritium retention under a neutron-irradiation environment. Under the framework of the US-Japan TITAN program, tungsten samples (99.99 at. % purity from A.L.M.T. Co.) were irradiated by neutron in the High Flux Isotope Reactor (HFIR), ORNL, at 50 and 300C to 0.025, 0.3, and 1.2 dpa, and the investigation of deuterium retention in neutron-irradiation was performed in the INL Tritium Plasma Experiment (TPE), the unique high-flux linear plasma facility that can handle tritium, beryllium and activated materials. This paper reports the recent results from the comparison of ion-damaged tungsten via various ion species (2.8 MeV Fe2+, 20 MeV W2+, and 700 keV H-) with that from neutron-irradiated tungsten to identify the similarities and differences among them.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Temperature measurement through detailed balance in X-ray Thomson scattering

The plasma conditions in isochorically heated beryllium are measured by x-ray Thomson scattering in the collective regime with a Cl Ly-{alpha} x-ray source at 2.96 keV. In addition to the down-shifted plasmon shape which provides electron density and temperature information, an up-shifted plasmon signal is observed allowing a model independent determination of the plasma temperature from the detailed balance relation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An overview of research activities on materials for nuclear applications at the INL Safety, Tritium and Applied Research facility

The Safety, Tritium and Applied Research facility at the Idaho National Laboratory is a US Department of Energy National User Facility engaged in various aspects of materials research for nuclear applications related to fusion and advanced fission systems. Research activities are mainly focused on the interaction of tritium with materials, in particular plasma facing components, liquid breeders, high temperature coolants, fuel cladding, cooling and blanket structures and heat exchangers. Other activities include validation and verification experiments in support of the Fusion Safety Program, such as beryllium dust reactivity and dust transport in vacuum vessels, and support of Advanced Test Reactor irradiation experiments. This paper presents an overview of the programs engaged in the activities, which include the US-Japan TITAN collaboration, the US ITER program, the Next Generation Power Plant program and the tritium production program, and a presentation of ongoing experiments as well as a summary of recent results with emphasis on fusion relevant materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shape memory properties and microstructural evolution of rapidly solidified CuAlBe alloys

In this work, the effects of Be addition on the microstructure and phase transformation temperatures of Cu–12Al–xBe (x = 0.4, 0.5 and 0.6 wt.%) shape memory alloys fabricated by using the arc-melting and melt-spinning techniques have been investigated. X-ray diffraction analysis revealed that the arc-melted alloys consisted of austenitic β{sub 1}, martensitic β{sub 1}′ and γ{sub 2} precipitate phases, whereas melt-spun ribbons were composed of a fully martensitic phase. The average grain size of martensitic phases in melt-spun ribbons was determined by electron microscopy images, showing a decrease with increasing Beryllium (Be) amount. Moreover, it was found that the Be addition in the arc-melted alloys had a distinct effect on the morphology of the γ{sub 2} precipitate phase. Transmission electron microscopy analysis showed that the thickness of martensitic plates in the melt-spun ribbons reduced with increasing Be addition. In a differential scanning calorimeter analysis, no martensitic transformation (M{sub s}) peak was observed in arc-melted alloys, but it was clearly detected in melt-spun ribbons, in which M{sub s} decreased dramatically with increasing Be addition. The improvement in the shape memory ability of melt-spun ribbons was explained in terms of the refinement in grain size and martensitic plates. - Highlights: • The CuAlBe SMAs were produced by means of arc-melter and melt-spinner techniques. • MT was directly obtained in melt-spuns without any intermediate process. • The transformation temperatures decreased with increasing Be amount. • The thickness of martensitic plates in the ribbons reduced with increasing Be. • SMP of CuAl was improved by the addition of Be together with rapid solidification.

36 MATERIALS SCIENCE↗

Paleoclimatic implications of glacial fluctuations in the Sierra Nevada del Cocuy, northern Andes, Colombia, during the Lateglacial and Holocene

The reconstruction of former mountain glaciers from geomorphic mapping and cosmogenic-nuclide surface-exposure dating provides a unique opportunity to infer patterns of past terrestrial climate variability. Tropical mountain glaciers are particularly valuable as there are comparatively few terrestrial climate proxies at equatorial latitudes relative to higher latitudes. As the single largest climate zone on Earth, the tropics play an outsized role in mediating global climate via the ocean-atmosphere transfer of latent heat and water vapor. Nonetheless, there remains a persistent gap in our understanding of how the tropics influenced – or were influenced by – the high-magnitude climate shifts of the Late Pleistocene, and whether this high-energy region simply responded to extratropical forcing or was itself a driver of global climatic change. To help address this knowledge gap, we analyzed geologic evidence for past glacial fluctuations in three adjacent valleys in the Sierra Nevada del Cocuy, the highest subrange of the Eastern Cordillera in the Colombian Andes, to provide a terrestrial record of atmospheric temperature during the latter part of Termination 1. Coupled with geomorphic mapping and paleo-snowline reconstructions, our beryllium-10 glacial chronology indicates that glaciers in the humid inner tropics underwent pronounced growth and gradual decay during the Antarctic Cold Reversal (14.5–12.8 ka) and Younger Dryas (12.8–11.7 ka) periods, respectively, following a trend that, according to directly dated moraine records from throughout both polar hemispheres, appears to have been global. While the specific mechanism(s) behind this large-scale behavior remains to be corroborated, we revisit the hypothesis that ocean-atmosphere heat transfer and water vapor flux are key drivers of abrupt Lateglacial temperature fluctuations. Subsequent to the Lateglacial, deglaciation of the Sierra Nevada del Cocuy accelerated during the Early Holocene, a pattern also observed in other tropical glacier records. More recently, the magnitude of snowline rise and glacier retreat over the last two centuries supports the view that modern tropospheric warming is anomalously strong at least relative to the last ∼16,000 years.

Andes↗

Tungsten-induced carcinogenesis in human bronchial epithelial cells

Metals such as arsenic, cadmium, beryllium, and nickel are known human carcinogens; however, other transition metals, such as tungsten (W), remain relatively uninvestigated with regard to their potential carcinogenic activity. Tungsten production for industrial and military applications has almost doubled over the past decade and continues to increase. Here, for the first time, we demonstrate tungsten's ability to induce carcinogenic related endpoints including cell transformation, increased migration, xenograft growth in nude mice, and the activation of multiple cancer-related pathways in transformed clones as determined by RNA sequencing. Human bronchial epithelial cell line (Beas-2B) exposed to tungsten developed carcinogenic properties. In a soft agar assay, tungsten-treated cells formed more colonies than controls and the tungsten-transformed clones formed tumors in nude mice. RNA-sequencing data revealed that the tungsten-transformed clones altered the expression of many cancer-associated genes when compared to control clones. Genes involved in lung cancer, leukemia, and general cancer genes were deregulated by tungsten. Taken together, our data show the carcinogenic potential of tungsten. Further tests are needed, including in vivo and human studies, in order to validate tungsten as a carcinogen to humans. - Highlights: • Tungsten (W) induces cell transformation and increases migration in vitro. • W increases xenograft growth in nude mice. • W altered the expression of cancer-related genes such as those involved in leukemia. • Some of the dysregulated leukemia genes include, CD74, CTGF, MST4, and HOXB5. • For the first time, data is presented that demonstrates tungsten's carcinogenic potential.

60 APPLIED LIFE SCIENCES↗

Developing one-dimensional implosions for inertial confinement fusion science

Experiments on the National Ignition Facility show that multi-dimensional effects currently dominate the implosion performance. Low mode implosion symmetry and hydrodynamic instabilities seeded by capsule mounting features appear to be two key limiting factors for implosion performance. One reason these factors have a large impact on the performance of inertial confinement fusion implosions is the high convergence required to achieve high fusion gains. To tackle these problems, a predictable implosion platform is needed meaning experiments must trade-off high gain for performance. LANL has adopted three main approaches to develop a one-dimensional (1D) implosion platform where 1D means measured yield over the 1D clean calculation. A high adiabat, low convergence platform is being developed using beryllium capsules enabling larger case-to-capsule ratios to improve symmetry. The second approach is liquid fuel layers using wetted foam targets. With liquid fuel layers, the implosion convergence can be controlled via the initial vapor pressure set by the target fielding temperature. The last method is double shell targets. For double shells, the smaller inner shell houses the DT fuel and the convergence of this cavity is relatively small compared to hot spot ignition. However, double shell targets have a different set of trade-off versus advantages. As a result, details for each of these approaches are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inhalation of Trace Metals in Secondhand and Thirdhand Tobacco Smoke Can Result in Increased Health Risks

Here, the presence of toxic metals in tobacco smoke is well documented. However, few studies have quantified trace metals in secondhand smoke (SHS) and thirdhand smoke (THS). Their presence in indoor air can contribute to nonsmokers’ exposures and health effects. In this study, emission and deposition rates of toxic trace metals were determined, and their airborne concentration in typical indoor scenarios was predicted. PM 2.5 was collected on Teflon-coated filters at various times following a smoking event in a room-sized chamber over a 43 h period. The concentration of 28 trace metals was determined by extraction and analysis using inductively coupled plasma-triple quadrupole-mass spectrometry (ICP-QQQ-MS). Emission and indoor deposition rates of cadmium, arsenic, chromium, manganese, beryllium and selenium were determined, and used to predict concentrations expected in a smokers’ home and a smoking bar. In most of the considered scenarios, average indoor concentrations of Cd, As, and Cr exceeded their corresponding cancer risk thresholds and, in some cases, also noncancer reference exposure levels, more than 3 h after smoking ended. The fraction of cadmium that remained airborne was significantly higher than those of other metal traces and that of PM 2.5 , suggesting an association of Cd traces with small particles.

60 APPLIED LIFE SCIENCES↗

Energy resolved soft x-ray imaging using a charge coupled device camera for long pulse discharges in the Large Helical Device

Energy resolved soft x-ray imaging system using a charge coupled device camera and a multifilter disk has recently been installed to the Large Helical Device for the measurements in the long pulse discharges. Eight images with different cutoff energies are measured sequentially during a single discharge by rotating a filter disk mounting eight beryllium filters with different thicknesses. A tangential line-integrated profile for a specific photon energy range can be obtained by taking intensity difference between two images measured with a filter pair of adjacent thicknesses. The typical photon energy corresponding to each difference ranges from 1.9 to 4.8 keV with the bandwidth of 2-3 keV. In the initial results, the difference in the line-integrated soft x-ray profile by the energy range has been clearly observed. This diagnostic method can possibly be applied to the observation of the dependence of two dimensional soft x-ray profile on photon energy range especially if local non-Maxwellian component appears in electron energy distribution function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2E1 Ar{sup 17+} decay and conventional radioactive sources to determine efficiency of semiconductor detectors

Although reliable models may predict the detection efficiency of semiconductor detectors, measurements are needed to check the parameters supplied by the manufacturers, namely, the thicknesses of dead layer, beryllium window, and crystal active area. The efficiency of three silicon detectors has been precisely investigated in their entire photon energy range of detection. In the zero to a few keV range, we developed a new method based on the detection of the 2E1 decay of the metastable Ar{sup 17+} 2s{yields}1s transition. Very good theoretical knowledge of the energetic distribution of the 2E1 decay mode enables precise characterization of the absorbing layers in front of the detectors. In the high-energy range (>10 keV), the detector crystal thickness plays a major role in the detection efficiency and has been determined using a {sup 241}Am source.

43 PARTICLE ACCELERATORS↗

Tritium Retention and Removal in Tokamaks

Management of tritium inventory remains one of the grand challenges in the development of fusion energy. Tritium is an important source term in safety assessments, it is expensive and in short supply. Tritium can be continuously retained in a tokamak by codeposition with eroded carbon or beryllium and JET and TFTR with carbon plasma facing components showed a tritium retention level that would be unacceptable in ITER or future fusion reactors. Asdex-U and Alcator C-mod have shown reduced hydrogenic retention with tungsten clad and molybdenum plasma facing components. Once the tritium inventory approaches the administrative limit, tritium must be removed to permit continued D-T plasma operations. Several candidate techniques are being considered and need to be proven at a relevant speed and efficiency in contemporary tokamaks. Projections for ITER are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Fluorescence (XRF) Assay Using Laser Compton Scattered (LCS) X-rays

Laser Compton Scattered (LCS) X-rays are produced as a result of the interaction between accelerated electrons and a laser beam. The yield of LCS X-rays is dependent on the laser power, angle of collision between interacting particles, and the electron linear accelerator's (linac) electron beam energy and its current. One of our research goals at the Idaho Accelerator Center (IAC) focuses on applications such as detection and imaging of fissionable isotopes for nuclear non-proliferation, safeguards and homeland security. Quasi monochromatic LCS X-rays offer much better signal-to-noise ratios for such applications. The energy of LCS X-rays is tunable, that enable element-specific analysis. Two sharp 36.5 keV and 98.4 keV LCS peaks were observed in two separate experiments based on electron beams tuned at 32 MeV and 37 MeV, that were brought in collision with the (Power){sub peak} = 4 GW Nd.YAG laser operating at 532 nm and 266 nm wavelengths. The linac was operating at 60 Hz with an electron beam pulse length of about 50 ps and a peak current of about 7 A. We exploited X-ray fluorescence (XRF) techniques to identify elemental K{alpha}{sub 1}, K{alpha}{sub 2}, and K{beta}{sub 1} lines in a high-purity germanium (HPGe) detector, with a 0.5 mm thick Beryllium (Be) absorbing layer, emitted from tin (Sn), cadmium (Cd), silver (Ag), gold (Au), and lead (Pb) foils with thicknesses ranging from 25-500 {mu}m, following absorption of 36.1 keV and 98.4 keV LCS X-rays. These reference foils were used for the proof of principle, and some have atomic numbers near to that of relevant fission products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic Data For Core And Edge Modeling

Future magnetic fusion energy devices, will have both very high Z (tungsten) and low Z (beryllium) plasma facing components, are setting the agenda for current atomic data needs. Data for the light species are in good shape but the heavy species present some challenges. We outline an approach for systematic heavy element data production for fusion applications in addition to techniques for handling the large amount of data in modeling codes efficiently.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mixed Material Plasma-Surface Interactions in ITER: Recent Results from the PISCES Group

This paper summarizes recent PISCES studies focused on the effects associated with mixed species plasmas that are similar in composition to what one might expect in ITER. Formation of nanometer scale whiskerlike features occurs in W surfaces exposed to pure He and mixed D/He plasmas and appears to be associated with the formation of He nanometer-scaled bubbles in the W surface. Studies of Be-W alloy formation in Be-seeded D plasmas suggest that this process may be important in ITER all metal wall operational scenarios. Studies also suggest that BeD formation via chemical sputtering of Be walls may be an important first wall erosion mechanism. D retention in ITER mixed materials has also been studied. The D release behavior from beryllium co-deposits does not appear to be a diffusion dominated process, but instead is consistent with thermal release from a number of variable trapping energy sites. As a result, the amount of tritium remaining in codeposits in ITER after baking will be determined by the maximum temperature achieved, rather than by the duration of the baking cycle.

36 MATERIALS SCIENCE↗

Measurements of magneto-Rayleigh-Taylor instability growth during the implosion of initially solid metal liners

A recent publication [D. B. Sinars et al., Phys. Rev. Lett. 105, 185001 (2010)] describes the first controlled experiments measuring the growth of the magneto-Rayleigh-Taylor instability in fast ({approx}100 ns) Z-pinch plasmas formed from initially solid aluminum tubes (liners). Sinusoidal perturbations on the surface of these liners with wavelengths of 25-400 {mu}m were used to seed single-mode instabilities. The evolution of the outer liner surface was captured using multiframe 6.151 keV radiography. The initial paper shows that there is good agreement between the data and 2-D radiation magneto-hydrodynamic simulations down to 50 {mu}m wavelengths. This paper extends the previous one by providing more detailed radiography images, detailed target characterization data, a more accurate comparison to analytic models for the amplitude growth, the first data from a beryllium liner, and comparisons between the data and 3D simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intense Photoneutron Sources For Nuclear Material Detection

Intense neutron sources are essential for cargo inspection for a broad range of threats from explosives, to contraband, to nuclear materials and especially SNM (Special Nuclear Materials). To be effective over a wide range of cargo materials, in particular for hydrogenous cargo such as food, and to offer practical inspection times, the neutron source must be very strong, typically >10{sup 10} neutrons per second. Unfortunately there are currently no reasonably compact and economical neutron generators with the required intensities. The insufficiency and inadequacy of intense neutron sources are especially conspicuous in the {<=}2.5 MeV range (low voltage (d,D) generator). This energy range is needed if the strong signature of prompt fission neutrons ({approx_equal}3 per fission) is to be detected and discerned from the numerous source neutrons. The photonuclear reactions of x-rays from commercial linacs in appropriate converters can provide ample intensities of neutrons. These converters have a very low ({gamma},n) energy threshold: 1.67 MeV for beryllium and 2.23 MeV for deuterium. The intense x-ray beams provided by commercial x-ray systems, more than compensate for the relatively low ({gamma},n) cross-sections which are in the milli-barn range. The choice of converter material, the geometrical shape, dimensions and location relative to the x-ray source, determine the efficiency of the neutron conversion. For electron accelerators with less than 10 MeV, the preferred converters, Be and D{sub 2}O, are also very good neutron moderators. Thus, while increasing the converters' thickness leads to an increase in the overall neutron yield, this causes the softening of the neutron spectrum, which reduces the neutron penetration especially in hydrogenous cargos. Photoneutron sources can be optimized to meet specific needs such as maximum fission signals in various cargo materials of interest. Efficient photoneutron sources with different energy spectra were investigated. Conversion efficiency of more than 10-4 neutron per 9 MeV electron yielding neutron intensities of more than 10{sup 11} n/s for commercial 100 {mu}Amp electron accelerators has been modeled and designed. The simulation was validated in laboratory experiments using small Be and D{sub 2}O converters.

43 PARTICLE ACCELERATORS↗

Progress on a Be Cavity Design

Previous RF experiments with normal-conducting cavities have demonstrated that there is a significant degradation in maximum gradient when the cavity is subjected to a strong axial magnetic field. We have developed a model suggesting that a cavity with beryllium walls may perform better than copper cavities. In this paper we outline the issues that led us to propose fabricating a Be-wall cavity. We also discuss a concept for fabricating such a cavity and mention some of the manufacturing issues we expect to face.

43 PARTICLE ACCELERATORS↗