Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Analysis facilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Analysis of Energy Savings and CO2 Emission Reduction Contribution for Industrial Facilities in USA

Abstract Energy audits can identify energy consumptions, energy costs of the facility and evolve to develop measures to maximize efficiency, optimize supply energy, and eliminate waste. This paper investigates the potential energy savings at 20 different industrial sectors with 152 assessments for various facilities in Wisconsin, USA. On average, eight energy recommendations were suggested and applied in each facility. This paper provides a detailed guideline for each industry in terms of eight different energy categories: heating, ventilation, and air conditioning (HVAC) systems, heat recovery systems, electrical demand management, and utility bills, motors, compressors, waste management, and productivity enhancement, lighting, besides building envelope. In total, the energy savings were as follows: 98 million kWh in the shape of electricity, 561 billion British thermal units (BTUs) gas savings, 44 million gallons water savings, and 2-million-pound solid waste savings. Based on these savings, a 100-thousand-ton reduction in carbon dioxide emissions was obtained.

Energy & Fuels↗

Development of integrated neutronics and thermal analysis capabilities to support design and optimization of fusion engineering demonstration facility systems and blanket design (Final Scientific/Technical Report)

A fusion engineering demonstration facility would be the first step in the commercial fusion plant developmental pathway that aims to be an engineering demonstration of tritium self-sufficiency. One of the primary requirements for tritium self-sufficiency, as well as to ensure low plant tritium release to the external environment, is to minimize the tritium loss through the internal components, which requires accurate predictions of the tritium behavior for a wide range of materials and system conditions. This grant addressed the lack of a comprehensive model which accounts for particular conditions, such as the significance of temperature fields and neutronics information, and the systematic uncertainty quantification of associated material properties that impact tritium generation, utilization, and loss mechanisms in the blanket.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of integrated neutronics and thermal analysis capabilities to support design and optimization of fusion engineering demonstration facility systems and blanket design (Final Scientific/Technical Report)

A fusion engineering demonstration facility would be the first step in the commercial fusion plant developmental pathway that aims to be an engineering demonstration of tritium self- sufficiency. One of the primary requirements for tritium self-sufficiency, as well as to ensure low plant tritium release to the external environment, is to minimize the tritium loss through the internal components, which requires accurate predictions of the tritium behavior for a wide range of materials and system conditions. This grant addressed the lack of a comprehensive model which accounts for particular conditions, such as the significance of temperature fields and neutronics information, and the systematic uncertainty quantification of associated material properties that impact tritium generation, utilization, and loss mechanisms in the blanket.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of the T-97 Space Shuttle Solid Rocket Motor test facility

The history of the analyses for the hydraulic force control systems of the T-97 test facility is presented. Two approaches that were investigated for softening the hydraulic systems for improved performance are presented. A valve modification and inclusion of a proportional-integral controller that finally stabilized the system are described. A simulated test case is shown and compared to actual test data from the QM-7 test. The simulated results are very close to the real results but indicate a slightly higher open-loop gain than for the real system.

Williamson, Marlin J.↗

Analysis of Frost Prevention for Heat Recovery Ventilation in an Arctic Facility

Sub-Arctic environments present a unique challenge for the continuous operation of mechanical ventilation systems in occupied buildings where cold temperatures create complications for maintaining adequate air quality, efficiency, and system operability. Heat recovery ventilation is most difficult at the coldest temperatures, when there is the greatest availability to transfer heat between airstreams, due to the potential for frost accumulation in the exhaust airstream. Frost limits heat transfer and creates the potential for subsequent blockage of airflow. A successful frost prevention strategy is necessary to ensure that recovery ventilation systems function in locations with a large amount of annual heating degree days. Commonly, this is achieved by preheating outdoor air above freezing temperatures via airflow through a glycol-water mix hydronic coil before heat exchange occurs. Preheating the outdoor air proactively inhibits frost formation but is associated with a penalty to recovery efficiency. A commercial-scale heat recovery ventilator in a facility in Fairbanks, Alaska was analyzed for sensible recovery effectiveness and exhaust temperature at different winter conditions. The system utilized the common defrost strategy of preheating the air above-freezing with a static temperature control scheme. The heat transfer efficiency of the recovery ventilator was observed to be poor at various winter conditions with elevated exhaust temperatures indicating lost heat recovery effectiveness. Using prior findings on strategies for sub-freezing temperatures along with observed field conditions it was determined that a dynamic relationship between the coil and the exterior conditions would reduce the energy required to preheat the air and allow the heat exchanger to maximize effectiveness due to temperate difference. This reduction in preheated temperature of the air is achieved by modulating the temperature of the coil to keep the discharge air stream above a certain dewpoint temperature threshold, likely leading to energy savings for other sub-Arctic facilities using this frost control strategy.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Building High-Energy Silicon-Containing Batteries Using Off-The-Shelf Materials

The technology of silicon anodes appears to be reaching maturity, with high-energy Si cells already in pilot-scale production. However, the performance of these systems can be difficult to replicate in academic settings, making it challenging to translate research findings into solutions that can be implemented by the battery industry. Part of this difficulty arises from the lack of access to engineered Si particles and anodes, as electrode formulations and the materials themselves have become valuable intellectual property for emerging companies. Here, we summarize the efforts by Argonne’s Cell Analysis, Modeling, and Prototyping (CAMP) Facility in developing Si-based prototypes made entirely from commercially available materials. We describe the many challenges we encountered when testing high-loading electrodes (>5 mAh cm −2 ) and discuss strategies to mitigate them. With the right electrode and electrolyte design, we show that our pouch cells containing ≥ 70 wt% SiO x can achieve 600–1,000 cycles at C/3 and meet projected energy targets of 700 Wh L −1 and 350 Wh kg −1 . These results provide a practical reference for research teams seeking to advance silicon-anode development using accessible materials.

25 ENERGY STORAGE↗

Assessing thermal resilience of an assisted living facility during heat waves and cold snaps with power outages

Extreme hot and cold weather events are becoming more frequent, intense, and longer due to climate change. When these events occur coincidentally with power outages, the resulting extreme indoor temperatures pose a severe health hazard for occupants. This study conducted a holistic modeling and analysis of an assisted living facility, where senior residents live, to assess its thermal resilience performance under a six-day heat wave in 2015 and a three-day cold snap in 2021 with power outages. Impacts of 13 energy efficiency measures on thermal resilience and backup power capacity of the facility were evaluated. Three thermal resilience metrics: the SET (standard effective temperature) degree-hours, the Heat Index, and the Hours of Safety, were used and calculated from the EnergyPlus simulation models. Furthermore, major findings are: (1) the facility would suffer from extreme temperatures during the cold and hot events without a power supply, not meeting the passive survivability requirements; (2) most passive envelope measures improve thermal resilience for both hot and cold events, but making the building envelope airtight results in conflicting performance between the hot and cold events; (3) natural ventilation is an effective measure to mitigate summer indoor overheating; and (4) the energy efficiency package can reduce backup power capacity by 19% for the three-day cold snap. It is recommended that building technologies and design strategies be evaluated to consider co-benefits of energy use, thermal resilience, and backup power needs through building energy codes or policies for existing and new buildings, which are transitioning for decarbonization and climate resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of seals and lubricants used on the Long Duration Exposure Facility

This report described results from testing and analysis of seals and lubricants subsequent to the 69-month low-earth-orbit (LEO) exposure on the Long Duration Exposure Facility (LDEF). Results show that if the materials were shielded from exposure to LDEF's external environment, the 69-month exposure to LEO resulted in minimal changes to material properties. However, if the materials were exposed to LDEF's exterior environments (atomic oxygen, solar radiation, meteoroids, and/or space debris), a variety of events occurred, ranging from no material change, to changes in properties, to significant erosion of the material.

Dursch, H. W.↗

ExaFEL: extreme-scale real-time data processing for X-ray free electron laser science

ExaFEL is an HPC-capable X-ray Free Electron Laser (XFEL) data analysis software suite for both Serial Femtosecond Crystallography (SFX) and Single Particle Imaging (SPI) developed in collaboration with the Linac Coherent Lightsource (LCLS), Lawrence Berkeley National Laboratory (LBNL) and Los Alamos National Laboratory. ExaFEL supports real-time data analysis via a cross-facility workflow spanning LCLS and HPC centers such as NERSC and OLCF. Our work therefore constitutes initial path-finding for the US Department of Energy's (DOE) Integrated Research Infrastructure (IRI) program. We present the ExaFEL team's 7 years of experience in developing real-time XFEL data analysis software for the DOE's exascale supercomputers. We present our experiences and lessons learned with the Perlmutter and Frontier supercomputers. Furthermore we outline essential data center services (and the implications for institutional policy) required for real-time data analysis. Finally we summarize our software and performance engineering approaches and our experiences with NERSC's Perlmutter and OLCF's Frontier systems. This work is intended to be a practical blueprint for similar efforts in integrating exascale compute resources into other cross-facility workflows.

59 BASIC BIOLOGICAL SCIENCES↗

A Bayesian method to estimate the neutron response matrix of a single crystal CVD diamond detector

Detectors made from artificial chemical vapor deposition (CVD) single crystal diamond are very promising candidates for applications where high resolution neutron spectrometry in very high neutron fluxes is required, for example in fusion research. We propose a Bayesian method to estimate the neutron response function of the detector for a continuous range of neutron energies (in our case, 10 MeV ≤ E{sub n} ≤ 16 MeV) based on a few measurements with quasi-monoenergetic neutrons. This method is needed because a complete set of measurements is not available and the alternative approach of using responses based on Monte Carlo calculations is not feasible. Our approach uses Bayesian signal-background separation techniques and radial basis function interpolation methods. We present the analysis of data measured at the PTB accelerator facility PIAF. The method is quite general and it can be applied to other particle detectors with similar characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A systematic retrieval analysis of secondary eclipse spectra. II. A uniform analysis of nine planets and their C to O ratios

Secondary eclipse spectroscopy provides invaluable insights into the temperatures and compositions of exoplanetary atmospheres. We carry out a systematic temperature and abundance retrieval analysis of nine exoplanets (HD 189733b, HD 209458b, HD 149026b, GJ436b, WASP-12b, WASP-19b, WASP-43b, TrES-2b, and TrES-3b) observed in secondary eclipse using a combination of space- and ground-based facilities. Our goal with this analysis is to provide a consistent set of temperatures and compositions from which self-consistent models can be compared and to probe the underlying processes that shape these atmospheres. This paper is the second in a three part series of papers exploring the retrievability of temperatures and abundances from secondary eclipse spectra and the implications of these results for the chemistry of exoplanet atmospheres. In this investigation we present a catalogue of temperatures and abundances for H{sub 2}O, CH{sub 4}, CO, and CO{sub 2}. We find that our temperatures and abundances are generally consistent with those of previous studies, although we do not find any statistically convincing evidence for super-solar C to O ratios (e.g., solar C/O falls in the 1σ confidence intervals in eight of the nine planets in our sample). Furthermore, within our sample we find little evidence for thermal inversions over a wide range of effective temperatures (with the exception of HD 209458b), consistent with previous investigations. The lack of evidence for inversions for most planets in our sample over such a wide range of effective temperatures provides additional support for the hypothesis that TiO is unlikely to be the absorber responsible for the formation of these inversions.

79 ASTRONOMY AND ASTROPHYSICS↗

Materials and Nondestructive Evaluation Laboratoriers: User Test Planning Guide

The Materials and Nondestructive Evaluation Laboratory process, milestones and inputs are unknowns to first-time users. The Materials and Nondestructive Evaluation Laboratory Planning Guide aids in establishing expectations for both NASA and non- NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware developers. It is intended to assist their project engineering personnel in materials analysis planning and execution. Material covered includes a roadmap of the analysis process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, products, and inputs necessary to define scope of analysis, cost, and schedule are included as an appendix to the guide.

Schaschl, Leslie↗

Integration of SWPF into the DWPF Flowsheet: Gap Analysis and Test Matrix Development

Based on Revision 19 of the High Level Waste (HLW) System Plan, it is anticipated that the Salt Waste Processing Facility (SWPF) will be integrated into the Defense Waste Processing Facility (DWPF) flowsheet in October 2018 (or with Sludge Batch 11 (SB11)). Given that, Savannah River Remediation (SRR) has requested a technical basis be developed that validates the current Product Composition Control System (PCCS) models for use during the processing of the SWPF-based coupled flowsheet or that leads to the refinements of or modifications to the models that are needed so that the models may be used during the processing of the SWPF-based coupled flowsheet. To support this objective, Savannah River National Laboratory (SRNL) has completed three key interim activities prior to validation of the current or development of refined PCCS models over the anticipated glass composition region for SWPF processing. These three key activities include: (1) defining the glass compositional region over which SWPF is anticipated to be processed, (2) comparing the current PCCS model validation ranges to the SWPF glass compositional region from which compositional gaps can be identified, and (3) developing a test matrix to cover the compositional gaps.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Performance Computing Facility Operational Assessment 2015: Oak Ridge Leadership Computing Facility

Oak Ridge National Laboratory’s (ORNL’s) Leadership Computing Facility (OLCF) continues to surpass its operational target goals: supporting users; delivering fast, reliable systems; creating innovative solutions for high-performance computing (HPC) needs; and managing risks, safety, and security aspects associated with operating one of the most powerful computers in the world. The results can be seen in the cutting-edge science delivered by users and the praise from the research community. Calendar year (CY) 2015 was filled with outstanding operational results and accomplishments: a very high rating from users on overall satisfaction that ties the highest-ever mark set in CY 2014; the greatest number of core-hours delivered to research projects; the largest percentage of capability usage since the OLCF began tracking the metric in 2009; and success in delivering on the allocation of 60, 30, and 10% of core hours offered for the INCITE (Innovative and Novel Computational Impact on Theory and Experiment), ALCC (Advanced Scientific Computing Research Leadership Computing Challenge), and Director’s Discretionary programs, respectively. These accomplishments, coupled with the extremely high utilization rate, represent the fulfillment of the promise of Titan: maximum use by maximum-size simulations. The impact of all of these successes and more is reflected in the accomplishments of OLCF users, with publications this year in notable journals Nature, Nature Materials, Nature Chemistry, Nature Physics, Nature Climate Change, ACS Nano, Journal of the American Chemical Society, and Physical Review Letters, as well as many others. The achievements included in the 2015 OLCF Operational Assessment Report reflect first-ever or largest simulations in their communities; for example Titan enabled engineers in Los Angeles and the surrounding region to design and begin building improved critical infrastructure by enabling the highest-resolution Cybershake map for Southern California to date. The Titan system provides the largest extant heterogeneous architecture for computing and computational science. Usage is high, delivering on the promise of a system well-suited for capability simulations for science. This success is due in part to innovations in tracking and reporting the activity on the compute nodes, and using this information to further enable and optimize applications, extending and balancing workload across the entire node. The OLCF continues to invest in innovative processes, tools, and resources necessary to meet continuing user demand. The facility’s leadership in data analysis and workflows was featured at the Department of Energy (DOE) booth at SC15, for the second year in a row, highlighting work with researchers from the National Library of Medicine coupled with unique computational and data resources serving experimental and observational data across facilities. Effective operations of the OLCF play a key role in the scientific missions and accomplishments of its users. Building on the exemplary year of 2014, as shown by the 2014 Operational Assessment Report (OAR) review committee response in Appendix A, this OAR delineates the policies, procedures, and innovations implemented by the OLCF to continue delivering a multi-petaflop resource for cutting-edge research. This report covers CY 2015, which, unless otherwise specified, denotes January 1, 2015, through December 31, 2015.

97 MATHEMATICS AND COMPUTING↗

Hazard Analysis for Building 34 Vacuum Glove Box Assembly

One of the characteristics of an effective safety program is the recognition and control of hazards before mishaps or failures occur. Conducting potentially hazardous tests necessitates a thorough hazard analysis in order to prevent injury to personnel, and to prevent damage to facilities and equipment. The primary purpose of this hazard analysis is to define and address the potential hazards and controls associated with the Building 34 Vacuum Glove Box Assembly, and to provide the applicable team of personnel with the documented results. It is imperative that each member of the team be familiar with the hazards and controls associated with his/her particular tasks, assignments and activities while interfacing with facility test systems, equipment and hardware. In fulfillment of the stated purposes, the goal of this hazard analysis is to identify all hazards that have the potential to harm personnel, damage the facility or its test systems or equipment, test articles, Government or personal property, or the environment. This analysis may also assess the significance and risk, when applicable, of lost test objectives when substantial monetary value is involved. The hazards, causes, controls, verifications, and risk assessment codes have been documented on the hazard analysis work sheets in Appendix A of this document. The preparation and development of this report is in accordance with JPR 1700.1, "JSC Safety and Health Handbook" and JSC 17773 Rev D "Instructions for Preparation of Hazard Analysis for JSC Ground Operations".

Meginnis, Ian↗