Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Airport”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

2024 JISEA Annual Meeting: Session 1

This is the presentation for the 2024 JISEA Annual Meeting Session 1: Hard-to-Decarbonize Industries, which took place on February 26, 2024. The presentation includes slides from Chad Reese, Environmental Affairs Manager at the San Diego County Regional Airport Authority, on sustainability efforts at the San Diego International Airport; Jordan Lambert, Director of Ag Innovation at Colorado State University, on agricultural decarbonization; Ana Aday, Materials Science Researcher at NREL, on decarbonizing the cement and concrete industry; and Rolf Weberg, Director of the Natural Resource Research Institute at the University of Minnesota Duluth, on integrated industrial decarbonization.

agriculture decarbonization↗

Aviation security screening optimizer for risk and throughput (ASSORT)

The increasing number of air travelers each year presents a challenge as many airports are near their capacity in terms of resources and space for passenger screening. Fortunately, advancements in technologies like next-generation millimeter wave scanning offer solutions to ease this strain. The focus remains on managing risk while enhancing the passenger experience for the traveling public. The risk model presented in this paper known as the Aviation Security Screening Optimizer for Risk and Throughput (ASSORT) is designed to assess risk-based approaches for passenger screening and checkpoint operations. Additionally, ASSORT is exploring various traveler categories — general, trusted, and trusted-plus — along with different checkpoint screening Concept of Operations tailored to each traveler type. For instance, travelers with a higher trust level may experience fewer screening technologies, resulting in quicker processing times at the checkpoint. The output of ASSORT provides a risk score for predefined threat scenarios, as well as the overall risk to the checkpoint, aircraft, and airport by traveler type. In conclusion, benefits of using this tool include assessing the trade-offs between the overall risk associated with checkpoints and the throughput rate of passengers screened. We show for example the impact that different passenger volumes at the checkpoint can have on risk.

99 GENERAL AND MISCELLANEOUS↗

Review of Onsite Temperature and Solar Forecasting Models to Enable Better Building Design and Operations

Advanced building controls and energy optimization for new constructions and retrofits rely on accurate weather data. Traditionally, most studies utilize airport weather information as the decision inputs. However, most buildings are in environments that are quite different than those at the airport miles away. Tree cover, adjacent buildings, and micro-climate effects caused by the larger surrounding area can all yield deviations in air temperature, humidity, solar irradiance, and wind that are large enough to influence design and operation decisions. In order to overcome this challenge, there are many prior studies on developing weather forecasting algorithms from micro-to meso-scales. Additionally, this paper reviews and complies knowledge on common weather data resources, data processing methodologies and forecasting techniques of weather information. Commonly used statistical, machine learning and physical-based models are discussed and presented as two major categories: deterministic forecasting and probabilistic forecasting. Finally, evaluation metrics for forecasting errors are listed and discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatial Patterns and Trends of Summertime Low Cloudiness for the Pacific Northwest, 1996–2017

Summertime low clouds are common in the Pacific Northwest (PNW), but spatiotemporal patterns have not been characterized. We show the first maps of low cloudiness for the western PNW and North Pacific Ocean using a 22-year satellite-derived record of monthly mean low cloudiness frequency for May through September and supplemented by airport cloud base height observations. Domain-wide cloudiness peaks in midsummer and is strongest over the Pacific. Empirical orthogonal function (EOF) analysis identified four distinct PNW spatiotemporal modes: oceanic, terrestrial highlands, coastal, and northern coastal. There is a statistically significant trend over the 22-year record toward reduced low cloudiness in the terrestrial highlands mode, with strongest declines in May and June; however, this decline is not matched in the corresponding airport records. The coastal mode is partly constrained from moving inland by topographic relief and migrates southward in late summer, retaining higher late-season low cloud frequency than the other areas.

54 ENVIRONMENTAL SCIENCES↗

A Global LIS/OTD Climatology of Lightning Flash Extent Density

Previous lightning climatologies derived from Lightning Imaging Sensor (LIS) and Optical Transient Detector (OTD) total lightning measurements have quantified lightning frequency as a Flash Rate Density (FRD). This approach assumes that lightning flashes can be represented as points and quantifies the frequency of lightning centered in each grid cell. However, lightning has a finite extent that can reach hundreds of kilometers. A new climatology based on Flash Extent Density (FED) is constructed for LIS (including ISS-LIS) and OTD that accounts for the horizontal dimension of lightning. The FED climatology documents the frequency that an observer can expect lightning to be visible overhead—regardless of where the flash began or ended. This new FED climatology confirms and elaborates on the previous global LIS/OTD FRD and Americas-only Geostationary Lightning Mapper (GLM) findings. The FED climatology maintains Lake Maracaibo as the global lightning hotspot with an average of 389 flashes/day but designates Karabre in the Democratic Republic of the Congo as the global thunderstorm duty (percent of the total viewtime where lightning is observed) hotspot at 7.29%. Meanwhile, Kuala Lumpur is the national capital city with the most lightning, and its airport (KUL) is the top major airport affected by lightning (in terms of duty). The FED seasonal cycle and month-to-month changes in the “center of lightning” for the three continental chimney regions are also discussed.

54 ENVIRONMENTAL SCIENCES↗

Capture, storage, and re-use of liquid hydrogen boil-off for aviation and aerospace applications

Despite major interest in the use of liquid hydrogen as a fuel for aviation and aerospace sectors, loss of hydrogen through boil-off continues to be a hurdle as it causes financial loss, indirect greenhouse gas emissions, and safety concerns. Herein, we perform techno-economic analysis, calibrated with experimental measurements, to assess the use of sorbents to capture and condition hydrogen boil-off events in the range of 1.5 to 70 tonnes per day at launch sites and airports. We evaluate the direct delivery of captured boil-off to combustion engines and fuel cells, comparing against boil-off re-liquification and compression. Results indicate probable cost-effectiveness at delivered liquid hydrogen prices above 0.9 U.S. dollar ($) per kg H2 at airports, and above 10 $ per kg H2 at launch sites where 10% or more of hydrogen is lost to boil-off.

08 HYDROGEN↗

Behind-the-Meter Energy Storage and Generation in Support of Electrified Rental Car Centers

Electrification of rental car centers at major airports is expected to generate tens of MW in additional power loads. The magnitude of these loads poses challenges including high utility costs, expensive and lengthy distribution capacity upgrades, and disruptions to traditional operation. Behind-the-meter stationary battery storage and onsite photovoltaic generation offer a viable solution to these challenges without impacting the operation and business model of rental car companies, defined by minimal fleet inventory and short vehicle dwell time. Using data-driven syn-thetic charging loads for the rental car center at the Dallas/Fort Worth airport in the United States, we show that optimally-designed and controlled behind - the- meter resources can reduce the lifecycle cost of electrified rental centers by an average 41 % and reduce peak grid demand by 64 %, deferring the need for distribution upgrades or potentially avoiding it altogether.

battery storage↗

Athena - Digital Twin and Infrastructure Model [SWR 20-106]

The software provides database access and analysis code for project ATHENA data. In particular, it provides (1) access to the AWS RDS database and (2) supporting code for analysis. Additionally, the software contains all the code related to modeling the Dallas-Fort Worth International Airport (DFW) curbside (CTA modeling) using SUMO simulator. It demonstrates how to install, run and derive useful data from SUMO simulations. We will describe the basic files needed to run a simulation and how those files are generated. The software also has code for generating simulations representing different traffic management policies for DFW and simulating those policies on personal computer or on NREL's Eagle supercomputer. The examples provided are a representation of the DFW airport for curbside dropoff and and pickup.

Severino, Joseph↗

Athena - Shuttle Bus Optimization and Event Driven Simulator [SWR 20-105]

The primary purpose of the software is to optimize shuttle routes to and from terminals, given some airport campus location like the rental car center. This code was developed as part of the DOE funded Athena project. One aspect of the Athena project was to investigate if the optimization of shuttle routes that move passengers to and from the five DFW terminals and the rental car center could result in lower energy consumption from the shuttle fleet while still maintaining an acceptable level of service to passengers. Hence, the optimization done by the code determines a set of shuttle routes, the type of shuttle on each route, and the number of shuttles servicing each route. The optimization aims to make these choices in a way that the energy consumption per hour by the fleet is minimized. Additionally, the software can fast simulate airport shuttle operations with collected data. The simulation inputs are passenger arrival rates, shuttle routes and frequencies, and simulation configurations. The outputs include: time dependent shuttle energy level, time dependent charging station usage, time dependent number of passengers on each bus, time dependent number of passengers at each bus stop, history of number of passengers left at each bus stop, route history of fleet shuttle buses and on-demand buses, and time dependent bus distance traveled.

Kelly, Kenneth↗

NLR VISSIM Wrapper [SWR-26-023]

Software that allows the execution of VISSIM simulations based on any airport access/egress mode share scenario. This is a standalone executable that takes the baseline VISSIM model provided by Seattle Tacoma International Airport (SEA) and a synthetic passenger dataset as inputs and generates travel time changes based on the congestion evaluation function built into the software.

Ge, Yanbo [National Laboratory of the Rockies (NLR↗

Do Machine Learning Approaches Offer Skill Improvement for Short-Term Forecasting of Wind Gust Occurrence and Magnitude?

Abstract Wind gusts, and in particular intense gusts, are societally relevant but extremely challenging to forecast. This study systematically assesses the skill enhancement that can be achieved using artificial neural networks (ANNs) for forecasting of wind gust occurrence and magnitude. Geophysical predictors from the ERA5 reanalysis are used in conjunction with an autoregressive term in regression and ANN models with different predictors, and varying model complexity. Models are derived and assessed for the warm (April–September) and cold (October–March) seasons for three high passenger volume airports in the United States. Model uncertainty is assessed by deriving models for 1000 different randomly selected training (70%) and testing (30%) subsets. Gust prediction fidelity in independent test samples is critically dependent on inclusion of an autoregressive term. Gust occurrence probabilities derived using five-layer ANNs exhibit consistently higher fidelity than those from regression models and shallower ANNs. Inclusion of the autoregressive term and increasing the number of hidden layers in ANNs from 1 to 5 also improve the model performance for gust magnitudes (lower RMSE, increased correlation, and model standard deviations that more closely approximate observed values). Deeper ANNs (e.g., 20 hidden layers) exhibit higher skill in forecasting strong (17–25.7 m s −1 ) and damaging (≥25.7 m s −1 ) wind gusts. However, such deep networks exhibit evidence of overfitting and still substantially underestimate (by 50%) the frequency of strong and damaging wind gusts at the three airports considered herein. Significance Statement Improved short-term forecasting of wind gusts will enhance aviation safety and logistics and may offer other societal benefits. Here we present a rigorous investigation of the relative skill of models of wind gust occurrence and magnitude that employ different statistical methods. It is shown that artificial neural networks (ANNs) offer considerable skill enhancement over regression methods, particularly for strong and damaging wind gusts. For wind gust magnitudes in particular, application of deeper learning networks (e.g., five or more hidden layers) offers tangible improvements in forecast accuracy. However, deeper networks are vulnerable to overfitting and exhibit substantial variability with the specific training and testing data subset used. Also, even deep ANNs reproduce only half of strong and damaging wind gusts. These results indicate the need for future work to elucidate the dynamical mechanisms of intense wind gusts and advance solutions to their prediction.

54 ENVIRONMENTAL SCIENCES↗

Wind speed data from NCEI Marcos A Gelabert station, Panama, Jan 2008 – Dec 2019

This data package contains wind speed data retrieved from the National Oceanic and Atmospheric Administration's National Center for Environmental Information (NCEI). Measurements were collected at the Marcos A. Gilbert airport in Panama City, Panama. This station can be considered as an analogue to the NGEE Tropics Parque Natural Metropolitano site in Panama. In the attached Excel file, wind speed units have been converted from MPH to m/s (1MPH = 0.447 m/s). Data from NCEI can be accessed at: https://gis.ncdc.noaa.gov/maps/ncei/, STATION NAME: MARCOS A GELABERT (Airport in Panama City). Within the attached zip file are three .csv data files, three PDF files containing an explanation of gap filling procedures and site information, and a read.me text file with metadata and instructions for accessing data from NCEI.

54 ENVIRONMENTAL SCIENCES↗

SEDONA: SpEctroscopic Detection of Nerve Agents

Los Alamos National Laboratory developed the only portable screener to accurately detect the chemical nerve agents, providing results in seconds. Current airport detection system cannot scan for the threat of organophosphorus nerve agents and insecticides. Small quantities of these toxic chemicals can very quickly cause widespread exposure and severe symptoms. SEDONA screens through an unopened bottle using the principles of nuclear magnetic resonance spectroscopy. The system could be deployed and operated with minimal training. SEDONA dramatically reduces the likelihood of a successful nerve agent attack at airports, government buildings, embassies, sporting events, concerts, and political rallies.

47 OTHER INSTRUMENTATION↗

Port Authority of New York and New Jersey Sustainable Aviation Fuel Logistics and Production Study

The Port Authority of New York and New Jersey (PANYNJ) sustainability commitment is to meet the goals set by the Paris Agreement, with an interim greenhouse gas reduction target of 35% by 2025 and 80% by 2050. PANYNJ is seeking sustainable solutions to reduce carbon emissions for all public forms of transportation, including aviation. Similarly, the global aviation industry adopted the Carbon Offsetting and Reduction Scheme for International Aviation (CORSIA), which seeks to cap net carbon dioxide (CO 2 ) aviation emissions at 2020 levels through 2035. Industry has also set a goal of reducing CO 2 emissions by 50% compared to 2005 levels by 2050. Sustainable aviation fuel (SAF), made from non-petroleum feedstocks, is a near-term alternative fuel that reduces emissions from air transportation. The National Renewable Energy Laboratory (NREL) conducted a resource assessment and a techno-economic analysis to identify the potential for production in the port district. Although SAF could be sourced from other areas of the United States or imported, an evaluation of local production was conducted due to the potential positive impacts of a circular economy by converting local waste feedstocks into SAF for use at nearby airports. The study found that the highest volumes of feedstock nearby were municipal solid waste and woody biomass. SAF must be blended with Jet A up to certain percent determined by ASTM International fuel quality standards prior to use in aircraft. SAF from a stand-alone facility could be delivered by barge, rail, or truck to a Linden, New Jersey based terminal for blending with Jet A or it could be blended in the Gulf region and shipped via the Colonial pipeline to one of the terminals. The investment will take place at the terminal(s) to accommodate SAF/Jet A blends and it will be business as usual for the airports in how they receive fuel and distribute it to aircraft.

09 BIOMASS FUELS↗

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)↗

Package Data for CERF-Data Centers

This dataset contains sample input 100m resolution raster files for running the CERF-DC python package (see https://github.com/IMMM-SFA/cerf_data_centers) at the state level across the CONUS. Due to data availability constraints, some of the items included in this dataset are proxies or assumptions for siting factors used in the model. These are individually noted in the item descriptions and can be exchanged with more detailed information upon availability. Data Descriptions The following raster files are included in the data download: state_siting_region.tif — State areas identified by state FIPS code composite_siting_suitability.tif — Value of 1 indicates suitable siting location, 0 otherwise. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands land_value_dollar_per_sqft.tif — USD per square foot (sqft) derived from USDA $/acre land cost personal_property_tax_rate.tif — Personal property tax rate by state. Uses an assumed 0.0125 personal property tax rate for states with personal property tax, 0 for states without personal property tax. real_property_tax_rate.tif — Real property tax rate. Based on county level residential real estate property tax rates. sales_tax_rate.tif — Sales tax rate by state. mechanical_cooling_fraction.tif — Fraction of year (values between 0 and 1, inclusive) that the data center would be cooled through mechanical processes based on local water stress and humidity levels. water_cooling_fraction.tif — Fraction of year (values between 0 and 1, inclusive) that the data center would be cooled through evaporative (water cooled) processes based on local water stress and humidity levels. distance_to_substation.tif — Distance to nearest substation in hundreds of meters (i.e., value of 1 equals a distance of 100m). Offshore areas have a value of 0. industrial_electricity_rates_dollar_per_kwh.tif — USD/kWh industrial electricity rates. Represents the average industrial rate across all utilities that operate within a given county. Values are derived from the US Utility Rate Database. commercial_electricity_rates_dollar_per_kwh.tif — USD/kWh commercial electricity rates. Represents the average commercial rate across all utilities that operate within a given county. Values are derived from the US Utility Rate Database. data_center_market_locations.tif — Grid cells with positive values represent the centroid of existing data center market clusters. The value of non-zero grid cells represents the number of data centers in the market cluster. All other grid cells have a value of 0. Geospatial Metadata CRS: Albers Equal Area Conic (ESRI:102003) Extent: -2415585.0000000023283064,-1441981.2605773280374706 : 2384414.9999999976716936,1708018.7394226719625294 Dimensions: X: 48000 Y: 31500 Bands: 1 Origin: -2415585.0000000023283064,1708018.7394226719625294 Pixel Size: 100,-100 Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall↗

Aircraft-crash-locating transmitter features design improvements

Crash locater is automatically ejected from aircraft at time of crash and begins transmitting at emergency radio frequencies monitored by all airports and airport control towers. Advantages are smaller size, simpler design and installation, extended transmitting range and life, greater deployment reliability and increased crash resistance.

Manoli, R.↗