Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Distribution Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Total Thermal Management of Battery Electric Vehicles (BEVs)

The key hurdles to achieving wide consumer acceptance of battery electric vehicles (BEVs) are weather-dependent drive range, higher cost, and limited battery life. These translate into a strong need to reduce a significant energy drain and resulting drive range loss due to auxiliary electrical loads the predominant of which is the cabin thermal management load. Studies have shown that thermal subsystem loads can reduce the drive range by as much as 45% under ambient temperatures below -10°C. Often, cabin heating relies purely on positive temperature coefficient (PTC) resistive heating, contributing to a significant range loss. Reducing this range loss may improve consumer acceptance of BEVs. The authors present a unified thermal management system (UTEMPRA) that satisfies diverse thermal and design needs of the auxiliary loads in BEVs. Demonstrated on a 2015 Fiat 500e BEV, this system integrates a semi-hermetic refrigeration loop with a coolant network and serves three functions: (1) heating and/or cooling vehicle traction components (battery, power electronics, and motor) (2) heating and cooling of the cabin, and (3) waste energy harvesting and re-use. The modes of operation allow a heat pump and air conditioning system to function without reversing the refrigeration cycle to improve thermal efficiency. The refrigeration loop consists of an electric compressor, a thermal expansion valve, a coolant-cooled condenser, and a chiller, the latter two exchanging heat with hot and cold coolant streams that may be directed to various components of the thermal system. The coolant-based heat distribution is adaptable and saves significant amounts of refrigerant per vehicle. Also, a coolant-based system reduces refrigerant emissions by requiring fewer refrigerant pipe joints. The authors present bench-level test data and simulation analysis and describe a preliminary control scheme for this system.

Chowdhury, Sourav↗

Earth Science Technology Office (ESTO) New Observing Strategies (NOS) and NOS-Testbed (NOS-T)

With the advancement of space hardware technologies such as smaller spacecraft, component and instrument miniaturization and high performance space processors, and with the advancement of software technologies in artificial intelligence, big data analysis and autonomous decision making, Earth Science is looking at novel ways to observe phenomena that previously could not have been studied or would have been too expensive to study with traditional missions. In particular, the New Observing Strategies (NOS) component of the NASA Earth Science Technology Office (ESTO) Advanced Information Systems Technology (AIST) Program aims at leveraging these novel technologies as well as low cost and easy access to space to acquire multi-temporal or simultaneous multi-angular, multi-locations, multi-resolution and multi-spectral observations that will provide better multi-source measurements and will build a more dynamic and comprehensive picture of Earth Science phenomena that need to be studied and analyzed. For applications such as water resources management, air quality monitoring, biodiversity studies or disaster management, NOS will integrate the use of small instruments, small spacecraft, constellations of spacecraft and networks of sensors to design new missions that will provide the necessary measurements to improve future forecast and science modeling systems.Measurement acquisition will therefore be approached as a system of systems rather than on a mission basis, and a system of this complexity should not be expected to work without full integration and experimental characterization. Although most of the individual technologies enabling to link and coordinate multi-source observations are more or less mature, a few technologies need to be developed and all of them need to be integrated and tested as a system. In order for this validation to occur, the AIST Program is developing the NOS Testbed that includes 3 main goals:1.Validate novel NOS technologies, independently and as a system2.Demonstrate novel distributed operations concepts3.Socialize new Distributed Spacecraft Mission (DSM) and SensorWeb (SW) technologies and concepts to the science community by significantly retiring the risk of integrating these new technologies.The NOS Testbed will consist of multiple sensing nodes, simulated or actual, representing space, air and/or ground measurements, that are interconnected by a communications fabric (infrastructure that permits nodes to transmit and receive data between one another and interact with each other). Each node will be supported by hardware capabilities required to perform nodes monitoring and command & control, as well as intelligent "onboard" computing. The nodes will work together in a collaborative manner to demonstrate optimal science capabilities. The testbed will enable to validate technologies such as inter-node communication models, techniques and protocols; inter-node coordination; real-time data fusion and understanding; planning; sensor re-targeting; etc. Additionally, the testbed will have the capability to interact with various mission design tools, OSSEs and one or several forecast models. More details about the NOS Testbed will be presented at the confererence.

Earth Science missions; Advanced information Syste↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A System of Agents for Supporting Optimization and Control of a Connected Community

The residential sector consumes a significant portion of the electricity sold in the United States. Above 60% of the energy used in the sector is used to operate heating, ventilation, and air conditioning (HVAC) systems and water heating (WH) systems. With the increase of intelligence in the grid and the new decision and control options enabled by the Internet of Things; control of these devices can be used to support the grid. Therefore, this article presents a scalable multiagent system for optimizing HVAC and WH systems while maintaining comfort. It allows a utility to orchestrate the shifting of energy from critical periods without direct control, but instead by using a price signal. The architecture, optimization formulation, implementation strategy and results from an implementation project are discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative Analysis of Model Predictive Control and MPC-Informed Rule-Based Control for Thermal Storage Operation in Ultra-Low Temperature 4th Generation District Heating Networks

The integration of thermal storage and heat pumps in district heating networks (DHNs) can significantly enhance operational flexibility and energy efficiency; however, the practical deployment of advanced control strategies is often hindered by forecasting requirements and computational complexity. This study presents a comparative analysis of thermal storage control strategies in an ultra-low-temperature fourth-generation DHN, focusing on the development of a simplified rule-based control (RBC) explicitly informed by Model Predictive Control (MPC) behavior. The proposed methodology systematically analyzes the charging and discharging decisions of an MPC-controlled system under ideal forecasting conditions and extracts recurrent control patterns as a function of key system variables, including outdoor temperature, thermal demand, and electricity price. These patterns are translated into a set of structured time- and condition-based rules, resulting in an MPC-informed RBC that embeds predictive insights while preserving implementation simplicity and operational transparency. The approach is validated on a realistic mixed-use urban district in Denver, Colorado, USA, equipped with a centralized air-source heat pump, distributed water-to-water heat pumps, and a central thermal storage unit. Results show that the tuned RBC attains approximately 96% of ideal MPC economic performance (-27% of costs), preserves values of technical and environmental indicators (reduction only of 2-3%), and substantially reduces complexity. Sensitivity analyses further demonstrate the robustness of the RBC under varying operational conditions (i.e., ambient temperature, electricity price). Overall, the study demonstrates that MPC-informed rule-based control represents an effective trade-off between control performance and real-world applicability, enabling the integration of additional system components while maintaining simplicity, robustness, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of MP-PIC on Dual Interconnected Chemical Looping Cold Flow System: Validation Process with Hydrodynamic Experiments

Chemical looping with oxygen uncoupling (CLOU) is a promising carbon capture technologies, that utilizes a dual fluidized bed interconnected by loopseals to selectively separate oxygen from ambient air. This study validated Barracuda-VR® hydrodynamic simulations of dual circulating fluidized bed. The experiments were run on a scaled-down cold-flow unit of a 100 kW dual reactor to find the quantities of interest: circulation rate, bed mass location distribution, and pressure profile. The numerical parameters of time step and grid resolution were studied to find the numeric uncertainty for the quantities of interest. The scenario parameters of flowrates, particle densities, and particle voidage were studied. The uncertainty from the model parameters of tangent-to-wall, drag multiplier, and stress model were studied. Simulation and experimental results matched over some of the parameters studied. These can be used to scale the system back to the 100 kW dual reactor and to a larger system.

Hamilton, Matthew A↗

Transactive Control of Commercial Buildings for Demand Response

Transactive control is a type of distributed control strategy that uses market mechanism to engage self-interested responsive loads to achieve power balance in the electrical power grid. In this paper, we propose a transactive control approach of commercial building Heating, Ventilation, and Air- Conditioning (HVAC) systems for demand response. We first describe the system models, and identify their model parameters using data collected from Systems Engineering Building (SEB) located on our Pacific Northwest National Laboratory (PNNL) campus. We next present a transactive control market structure for commercial building HVAC system, and describe its agent bidding and market clearing strategies. Several case studies are performed in a simulation environment using Building Control Virtual Test Bed (BCVTB) and calibrated SEB EnergyPlus model. We show that the proposed transactive control approach is very effective at peak clipping, load shifting, and strategic conservation for commercial building HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aleutian Pribilof Islands Wind Energy Feasibility Study

Under this project, the Aleutian Pribilof Islands Association (APIA) conducted wind feasibility studies for Adak, False Pass, Nikolski, Sand Point and St. George. The DOE funds were also be used to continue APIA's role as project coordinator, to expand the communication network quality between all participants and with other wind interest groups in the state and to provide continued education and training opportunities for regional participants. This DOE project began 09/01/2005. We completed the economic and technical feasibility studies for Adak. These were funded by the Alaska Energy Authority. Both wind and hydro appear to be viable renewable energy options for Adak. In False Pass the wind resource is generally good but the site has high turbulence. This would require special care with turbine selection and operations. False Pass may be more suitable for a tidal project. APIA is funded to complete a False Pass tidal feasibility study in 2012. Nikolski has superb potential for wind power development with Class 7 wind power density, moderate wind shear, bi-directional winds and low turbulence. APIA secured nearly $\$$1M from the United States Department of Agriculture Rural Utilities Service Assistance to Rural Communities with Extremely High Energy Costs to install a 65kW wind turbine. The measured average power density and wind speed at Sand Point measured at 20m (66ft), are 424 W/m2 and 6.7 m/s (14.9 mph) respectively. Two 500kW Vestas turbines were installed and when fully integrated in 2012 are expected to provide a cost effective and clean source of electricity, reduce overall diesel fuel consumption estimated at 130,000 gallons/year and decrease air emissions associated with the consumption of diesel fuel. St. George Island has a Class 7 wind resource, which is superior for wind power development. The current strategy, led by Alaska Energy Authority, is to upgrade the St. George electrical distribution system and power plant. Avian studies in Nikolski and Sand Point have allowed for proper wind turbine siting without killing birds, especially endangered species and bald eagles. APIA continues coordinating and looking for funding opportunities for regional renewable energy projects. An important goal for APIA has been, and will continue to be, to involve community members with renewable energy projects and energy conservation efforts.

17 WIND ENERGY↗

Field Evaluation of Advances in Energy-Efficiency Practices for Manufactured Homes

Three side-by-side lab houses were built, instrumented and monitored in an effort to determine through field testing and analysis the relative contributions of select technologies toward reducing energy use in new manufactured homes. The lab houses in Russellville, Alabama compared the performance of three homes built to varying levels of thermal integrity and HVAC equipment: a baseline HUD-code home equipped with an electric furnace and a split system air conditioner; an ENERGY STAR manufactured home with an enhanced thermal envelope and traditional split system heat pump; and a house designed to qualify for Zero Energy Ready Home designation with a ductless mini-split heat pump with transfer fan distribution system in place of the traditional duct system for distribution. Experiments were conducted in the lab houses to evaluate impact on energy and comfort of interior door position, window blind position and transfer fan operation. The report describes results of tracer gas and co-heating tests and presents calculation of the heat pump coefficient of performance for both the traditional heat pump and the ductless mini-split. A series of calibrated energy models was developed based on measured data and run in three locations in the Southeast to compare annual energy usage of the three homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nature of convection-stabilized dc arcs in dual-flow nozzle geometry. I - The cold flow field and dc arc characteristics. II - Optical diagnostics and theory

Steady-state low-current air arcs in a dual-flow nozzle system are studied experimentally. The cold flow field with no arc is investigated using a 12.7-mm diameter dual-flow nozzle in a steady-flow facility. Mach number and mass flux distributions are determined for various nozzle-pressure ratios and nozzle-gap spacing. It is found that the shock waves in the converging-diverging nozzles result in a decrease in overal resistance by about 15 percent. Also, Schlieren and differential interferometry techniques are used to visualize the density gradients within the arc plasma and thermal mantle. Both optical techniques reveal a laminar arc structure for a reservoir pressure of 1 atm at various current levels. Experimentally determined axial static pressure and cold-flow mass flux rate distributions and a channel-flow model with constant arc temperatre are used to solve the energy integral for the arc radius as a function of axial distance. The arc electric field strength, voltage, resistance, and power are determined with Ohm's law and the total heat transfer is related to arc power.

Serbetci, Ilter↗

High energy density aluminum-oxygen cell

An alternative to a secondary battery as the power source for vehicle propulsion is a fuel cell. An example of this is the metal-air fuel cell using metals such as aluminum, zinc, or iron. Aluminum is a particularly attractive candidate, having high energy and power densities, being environmentally acceptable, and having a large, established industrial base for production and distribution. An aluminum-oxygen system is currently under development for a UUV test vehicle, and recent work has focussed upon low corrosion aluminum alloys and an electrolyte management system for processing the by-products of the energy-producing reactions. This paper summarizes the progress made in both areas. Anode materials capable of providing high utilization factors over current densities ranging from S to 150 mA/sq cm have been identified. These materials are essential to realizing an acceptable mission life for the UUV. With respect to the electrolyte management system, a filter/precipitator unit has been successfully operated for over 250 hours in a large scale, half-cell system.

Rudd, E. J.↗

The Life Cycles of Intense Cyclonic and Anticyclonic Circulation Systems Observed over Oceans

This report presents a summary of research accomplished over the past four years under the sponsorship of NASA grant #NAG8-915. Building on previously funded NASA grants, this part of the project focused on the following specific goals relative to cyclone/anticyclone systems: the jet streak link between block formation and upstream cyclone activity; the role of northward warm air advection in block formation; the importance of cooperative participation of several forcing mechanisms during explosive cyclone development; and the significance of the vertical distribution of forcing processes during cyclone/anticyclone development.

Smith, Phillip J.↗

Goddard Atmospheric Composition Data Center: Aura Data and Services in One Place

The Goddard Atmospheric Composition Data and Information Services Center (AC-DISC) is a portal to the Atmospheric Composition specific, user driven, multi-sensor, on-line, easy access archive and distribution system employing data analysis and visualization, data mining, and other user requested techniques for the better science data usage. It provides convenient access to Atmospheric Composition data and information from various remote-sensing missions, from TOMS, UARS, MODIS, and AIRS, to the most recent data from Aura OMI, MLS, HIRDLS (once these datasets are released to the public), as well as Atmospheric Composition datasets residing at other remote archive site.

Leptoukh, G.↗

Design, Prototyping, and Testing of a Novel Flowpath with an Array of Six 3D Matrix Vitvo Bioreactors for the NASA Bioculture System

The NASA Bioculture System is an advanced cell culture closed-loop system containing highly automated flowpaths designed to conduct long term biology experiments on ISS with earth remote controllable medium flow, temperature, gas composition, medium exchange, cell sampling and fixation. This technology was already demonstrated with successful cardiomyocyte and osteocyte cultures experiments onboard the ISS and is now supporting NASA PI science. The Bioculture System, however, can only support 10 cassettes with disposable flowpaths, each containing a single hollow fiber bioreactor with a culture capacity of about 2ml. This constraint not only severely limits the number of investigators that can conduct experiments in space, but also subjects the experiments to limitations in the number of replicates and conditions that can be studied. To address these limitations, we sought a novel design solution to maximize the number of separate bioreactor cultures and volume that can be conducted simultaneously. To this end we designed, prototyped, and are now testing a six-Vitvo 3D Matrix 2ml bioreactor insert that replaces the conventional Bioculture System hollow fiber bioreactor. This design will allow the Bioculture System to support up to 60 different bioreactors and samples at once. Specifically, the novel gas-tight containment housing insert contains six COTS Rigenerand VITVO bioreactors stacked on each side of a heat sink powered by the existing heating element and pair of temperature sensors. Medium will be distributed into each bioreactor's cell-free chamber via its built-in Luer connector, then across the 3D matrix to the cell chamber, dissipating laminar flow and limiting fluid shear stresses that might mechanostimulate cell cultures. Gas (5% CO2 in air) will be supplied directly to the bioreactor gas-tight housing for exchange via the bioreactor flat-surface gas-permeable membranes, eliminating the need for the existing Bioculture System cassette oxygenator. If successfully implemented on ISS, this new multi-bioreactor insert for the Bioculture System has the potential to make real-time cell science experimentation in space more efficient and accessible to more investigators.

Ma, Kristin R.↗

Thermal Energy Storage for Electricity Peak-demand Mitigation: A Solution in Developing and Developed World Alike

In much of the developed world, air-conditioning in buildings is the dominant driver of summer peak electricity demand. In the developing world a steadily increasing utilization of air-conditioning places additional strain on already-congested grids. This common thread represents a large and growing threat to the reliable delivery of electricity around the world, requiring capital-intensive expansion of capacity and draining available investment resources. Thermal energy storage (TES), in the form of ice or chilled water, may be one of the few technologies currently capable of mitigating this problem cost effectively and at scale. The installation of TES capacity allows a building to meet its on-peak air conditioning load without interruption using electricity purchased off-peak and operating with improved thermodynamic efficiency. In this way, TES has the potential to fundamentally alter consumption dynamics and reduce impacts of air conditioning. This investigation presents a simulation study of a large office building in four distinct geographical contexts: Miami, Lisbon, Shanghai, and Mumbai. The optimization tool DER-CAM (Distributed Energy Resources Customer Adoption Model) is applied to optimally size TES systems for each location. Summer load profiles are investigated to assess the effectiveness and consistency in reducing peak electricity demand. Additionally, annual energy requirements are used to determine system cost feasibility, payback periods and customer savings under local utility tariffs.

25 ENERGY STORAGE↗

Building America Case Study: Southern Energy Homes, First DOE Zero Energy Ready Manufactured Home, Russellville, Alabama

Three side-by-side lab houses were built, instrumented and monitored in an effort to determine through field testing and analysis the relative contributions of select technologies toward reducing energy use in new manufactured homes.The lab houses in Russellville, Alabama compared the performance of three homes built to varying levels of thermal integrity and HVAC equipment: a baseline HUD-code home equipped with an electric furnace and a split system air conditioner; an ENERGY STAR manufactured home with an enhanced thermal envelope and traditional split system heat pump; and a house designed to qualify for Zero Energy Ready Home designation with a ductless mini-split heat pump with transfer fan distribution system in place of the traditional duct system for distribution. Experiments were conducted in the lab houses to evaluate impact on energy and comfort of interior door position, window blind position and transfer fan operation. The report describes results of tracer gas and co-heating tests and presents calculation of the heat pump coefficient of performance for both the traditional heat pump and the ductless mini-split. A series of calibrated energy models was developed based on measured data and run in three locations in the Southeast to compare annual energy usage of the three homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Time- and space-resolved quantitative LIF measurements of formaldehyde in a heavy-duty diesel engine

Formaldehyde (CH{sub 2}O) is a characteristic species for the ignition phase of diesel-like fuels. As such, the spatio-temporal distribution of formaldehyde is an informative parameter in the study of the ignition event in internal combustion engines, especially for new combustion modes like homogeneous charge compression ignition (HCCI). This paper presents quantitative data on the CH{sub 2}O distribution around diesel and n-heptane fuel sprays in the combustion chamber of a commercial heavy-duty diesel engine. Excitation of the 4{sub 0}{sup 1} band (355 nm) as well as the 4{sub 0}{sup 1}2{sub 0}{sup 1} band (339 nm) is applied. We use quantitative, spectrally resolved laser-induced fluorescence, calibrated by means of formalin seeding, to distinguish the contribution from CH{sub 2}O to the signal from those of other species formed early in the combustion. Typically, between 40% and 100% of the fluorescence in the wavelength range considered characteristic for formaldehyde is in fact due to other species, but the latter are also related to the early combustion. Numerical simulation of a homogeneous reactor of n-heptane and air yields concentrations that are in reasonable agreement with the measurements. Formaldehyde starts to be formed at about 2 CA (crank angle degrees) before the rise in main heat release. There appears to be a rather localised CH{sub 2}O formation zone relatively close to the injector, out of which formaldehyde is transported downstream by the fuel jet. Once the hot combustion sets in, formaldehyde quickly disappears. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Materials Performance in USC Steam

Goals of the U.S. Department of Energy's Advanced Power Systems Initiatives include power generation from coal at 60% efficiency, which requires steam conditions of up to 760 C and 340 atm. Towards this end, further validation of a previously developed chromia evaporation model is shown by examining the reactive evaporation effects resulting from exposure of Haynes 230 and Haynes 282 to moist air environments as a function of flow rate and water content. These two alloys differ in Ti and Mn contents, which may form outer layers of TiO{sub 2} or Cr-Mn spinels. This would in theory decrease the evaporation of Cr{sub 2}O{sub 3} from the scale by decreasing the activity of chromia at the scale surface, and be somewhat self-correcting as chromia evaporation concentrates the Ti and Mn phases. The apparent approximate chromia activity was found for each condition and alloy that showed chromia evaporation kinetics. As expected, it was found that increasing the gas flow rate led to increased chromia evaporation and decreased chromia activity. However, increasing the water content in moist air increased the evaporation, but results were mixed with its effect on chromia activity.

01 COAL, LIGNITE, AND PEAT↗