In Situ Synchrotron Tensile Investigations on Ultrasonic Additive Manufactured (UAM) Zirconium
The microstructure evolution of ultrasonic additive manufactured (UAM) zirconium under room temperature uniaxial tensile straining is reported. Miniature dog-bone tensile specimens of two orientations were cut from a UAM zirconium bar for in situ synchrotron tensile tests. Wide-angle X-ray scattering (WAXS) scanning at the Advanced Photon Source (APS) at Argonne National Laboratory was used to unveil the changes in microstructure of the entire gauge regions throughout the straining. A series of WAXS data analysis methods were utilized to quantify both elastic and plastic deformation mechanisms within the strained specimens. Stress concentrations were identified during early stage of plastic deformation, which become candidate necking positions and eventually lead to failure. Fracture surface analysis implied that these stress concentration locations may be correlated to the fabrication defects, providing insightful guidance for future improvement of the UAM zirconium process.