Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerated degradation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Neutron-Friendly Li-Ion Battery Coin Cell for In Situ 3D Visualization of Li Plating

Advanced battery characterization using in situ/operando neutron imaging is critical for uncovering degradation modes such as lithium (Li) plating in Li-ion batteries (LIBs). However, conventional LIBs hinder operando neutron radiography (NR) and in situ neutron micro-computed tomography (N-μCT) for visualizing Li plating near the graphite-separator interface due to strong attenuation from hydrogen-rich components like PP–PE–PP separators, electrolyte, and Fe-based spacers. In this work, we designed and tested a neutron-friendly battery (NFB) optimized for in situ Li detection during extreme fast charging (XFC). Guided by neutron attenuation cross-sections and material transmission, the NFB enables clear visualization at the graphite–separator interface, which is typically opaque in standard LIBs. Electrochemical tests show the NFB exhibits voltage/current responses like standard cells for up to 50 XFC cycles. However, its lower reversibility and capacity are likely due to Cu-coated Al spacer degradation from delamination or corrosion. We propose titanium spacers as a more stable alternative, albeit requiring custom machining. Using this optimized cell, we achieved simultaneous neutron tomography of multiple cells, capturing in situ 3D images of dead Li accumulation, particularly near graphite edges. These heterogeneous deposits and disconnected Li clusters suggest localized current density hotspots during XFC.

25 ENERGY STORAGE↗

PVDeg: Enhancing Usability and AI-Driven Multi-Mechanism Degradation Modeling

PVDeg version 0.7.0, released in December 2025, introduced major enhancements to improve usability and performance. This update reorganized tutorials and tool notebooks to create a more intuitive experience, enabling users to easily follow and adapt workflows for their specific analyses. In addition to structural improvements, both the notebooks and core logic underwent significant optimization for efficiency, robustness, and style. These refinements were supported by new testing frameworks built on nbval and pytest, adherence to PEP8 standards, and extensive code refactoring, which collectively simplify onboarding for new developers. Looking ahead, version 0.8.0 will deliver advanced AI-driven capabilities. The primary focus is to further develop and automate the degradation workflow, designed to analyze PV module degradation across diverse locations and system configurations. By integrating large language models (LLMs) to scan literature and compile a comprehensive database of materials and degradation rates, this feature will enable modeling of multiple materials and mechanisms within a single, streamlined workflow. Users will be able to evaluate degradation impacts on different system architectures under varying environmental conditions, facilitating informed decisions on bill-of-materials optimization for specific deployment scenarios. These advancements position PVDeg as a powerful, user-friendly tool for accelerating PV reliability research and system design.

14 SOLAR ENERGY↗

NASA Lewis advanced IPV nickel-hydrogen technology

Individual pressure vessel (IPV) nickel-hydrogen technology was advanced at NASA Lewis and under Lewis contracts. Some of the advancements are as follows: to use 26 percent potassium hydroxide electrolyte to improve cycle life and performance, to modify the state of the art cell design to eliminate identified failure modes and further improve cycle life, and to develop a lightweight nickel electrode to reduce battery mass, hence reduce launch and/or increase satellite payload. A breakthrough in the LEO cycle life of individual pressure vessel nickel-hydrogen battery cells was reported. The cycle life of boiler plate cells containing 26 percent KOH electrolyte was about 40,000 accelerated LEO cycles at 80 percent DOD compared to 3,500 cycles for cells containing 31 percent KOH. Results of the boiler plate cell tests have been validated at NWSC, Crane, Indiana. Forty-eight ampere-hour flight cells containing 26 and 31 percent KOH have undergone real time LEO cycle life testing at an 80 percent DOD, 10 C. The three cells containing 26 percent KOH failed on the average at cycle 19,500. The three cells containing 31 percent KOH failed on the average at cycle 6,400. Validation testing of NASA Lewis 125 Ah advanced design IPV nickel-hydrogen flight cells is also being conducted at NWSC, Crane, Indiana under a NASA Lewis contract. This consists of characterization, storage, and cycle life testing. There was no capacity degradation after 52 days of storage with the cells in the discharged state, on open circuit, 0 C, and a hydrogen pressure of 14.5 psia. The catalyzed wall wick cells have been cycled for over 22,694 cycles with no cell failures in the continuing test. All three of the non-catalyzed wall wick cells failed (cycles 9,588; 13,900; and 20,575). Cycle life test results of the Fibrex nickel electrode has demonstrated the feasibility of an improved nickel electrode giving a higher specific energy nickel-hydrogen cell. A nickel-hydrogen boiler plate cell using an 80 mil thick, 90 percent porous Fibrex nickel electrode has been cycled for 10,000 cycles at 40 percent DOD.

Smithrick, John J.↗

Telerobotic system concept for real-time soft-tissue imaging during radiotherapy beam delivery

Purpose: The curative potential of external beam radiation therapy is critically dependent on having the ability to accurately aim radiation beams at intended targets while avoiding surrounding healthy tissues. However, existing technologies are incapable of real-time, volumetric, soft-tissue imaging during radiation beam delivery, when accurate target tracking is most critical. The authors address this challenge in the development and evaluation of a novel, minimally interfering, telerobotic ultrasound (U.S.) imaging system that can be integrated with existing medical linear accelerators (LINACs) for therapy guidance. Methods: A customized human-safe robotic manipulator was designed and built to control the pressure and pitch of an abdominal U.S. transducer while avoiding LINAC gantry collisions. A haptic device was integrated to remotely control the robotic manipulator motion and U.S. image acquisition outside the LINAC room. The ability of the system to continuously maintain high quality prostate images was evaluated in volunteers over extended time periods. Treatment feasibility was assessed by comparing a clinically deployed prostate treatment plan to an alternative plan in which beam directions were restricted to sectors that did not interfere with the transabdominal U.S. transducer. To demonstrate imaging capability concurrent with delivery, robot performance and U.S. target tracking in a phantom were tested with a 15 MV radiation beam active. Results: Remote image acquisition and maintenance of image quality with the haptic interface was successfully demonstrated over 10 min periods in representative treatment setups of volunteers. Furthermore, the robot's ability to maintain a constant probe force and desired pitch angle was unaffected by the LINAC beam. For a representative prostate patient, the dose-volume histogram (DVH) for a plan with restricted sectors remained virtually identical to the DVH of a clinically deployed plan. With reduced margins, as would be enabled by real-time imaging, gross tumor volume coverage was identical while notable reductions of bladder and rectal volumes exposed to large doses were possible. The quality of U.S. images obtained during beam operation was not appreciably degraded by radiofrequency interference and 2D tracking of a phantom object in U.S. images obtained with the beam on/off yielded no significant differences. Conclusions: Remotely controlled robotic U.S. imaging is feasible in the radiotherapy environment and for the first time may offer real-time volumetric soft-tissue guidance concurrent with radiotherapy delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Design of the low-speed NLF(1)-0414F and the high-speed HSNLF(1)-0213 airfoils with high-lift systems

The design and testing of Natural Laminar Flow (NLF) airfoils is examined. The NLF airfoil was designed for low speed, having a low profile drag at high chord Reynolds numbers. The success of the low speed NLF airfoil sparked interest in a high speed NLF airfoil applied to a single engine business jet with an unswept wing. Work was also conducted on the two dimensional flap design. The airfoil was decambered by removing the aft loading, however, high design Mach numbers are possible by increasing the aft loading and reducing the camber overall on the airfoil. This approach would also allow for flatter acceleration regions which are more stabilizing for cross flow disturbances. Sweep could then be used to increase the design Mach number to a higher value also. There would be some degradation of high lift by decambering the airfoil overall, and this aspect would have to be considered in a final design.

Viken, Jeffrey K.↗

Mechanical Design of a High Energy Beam Absorber for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab

A high energy beam absorber has been built for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab. In the facility's initial configuration, an electron beam will be accelerated through 3 TTF-type or ILC-type SRF cryomodules to an energy of 750MeV. The electron beam will be directed to one of multiple downstream experimental and diagnostic beam lines and then deposited in one of two beam absorbers. The facility is designed to accommodate up to 6 cryomodules, which would produce a 75kW beam at 1.5GeV; this is the driving design condition for the beam absorbers. The beam absorbers consist of water-cooled graphite, aluminum and copper layers contained in a helium-filled enclosure. This paper describes the mechanical implementation of the beam absorbers, with a focus on thermal design and analysis. The potential for radiation-induced degradation of the graphite is discussed.

43 PARTICLE ACCELERATORS↗

UN-SiC TRISO Post Irradiation Examination Developmental Work

As part of efforts to strengthen INL?s post irradiation analysis capabilities with non-Advanced Gas Reactor (AGR) tristructural isotropic (TRISO) fuels, two developmental activities were conducted. The first activity was to determine how best to analyze uranium nitride TRISO fuel kernels using electron probe microanalysis, while the second activity focused on developing a method to deconsolidate TRISO fuel particles that have been encased in a silicon carbide matrix. Because these two activities were unrelated, they have been presented separately in this report. Initial EPMA analyses showed nitrogen contents that far exceeded the concentration expected for UN--a line compound. Further examination showed that current literature values for the mass absorption coefficient (MAC) for the N ka X-ray absorbed by U ranged from approximately 1600 to 9500, with most values tending toward 9500. Measuring UN with five different progressively increasing accelerating voltages followed by using the modeling program xMAC suggests the actual MAC is approximately 2115. Additional MAC modifications were required to produce reasonable analytical results. Because of the inaccuracies of necessary MAC coefficients, UN analysis via scanning electron microscopy (SEM) is likely to produce inaccurate results. This is because SEM software does not typically allow the user to alter MACs. Tests have been performed to examine the feasibility of an electrochemical technique to liberate irradiated TRISO fuel from a SiC matrix without damaging the outer pyrolytic carbon layer of the fuel particle. The method is performed by electrochemically exposing the SiC to magnesium metal forming Mg2Si and C. Following exposure, the small SiC samples showed slight mass increases with no evidence of conversion to Mg2Si and C nor obvious degradation of the SiC samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RaDIATE Collaboration for Material Studies

In the recent past, major accelerator facilities have been limited in beam power not by their accelerators, but by the beam intercepting device survivability. As next-generation accelerator target facilities (High Energy Physics, Spallation Sources, …) become increasingly more powerful and intense, high power target systems face key technical challenges. Beam-intercepting devices such as beam windows and secondary particle-production targets are continuously bombarded by high-energy high-intensity pulsed proton beams to produce secondary particles. Energy deposition from the primary beam induces near instantaneous heating (thermal shock) and microstructural changes (radiation damage) in the beam-intercepting materials. Both thermal shock and radiation damage ultimately degrade the performance and lifetime of targets and have been identified as the leading cross-cutting challenges of high-power target facilities. In order to operate reliable beam-intercepting devices in the framework of energy and intensity increase for next generation accelerators, the RaDIATE collaboration (Radiation Damage In Accelerator Target Environment) managed by Fermilab, brings together existing expertise in nuclear material and accelerator targets from 20 international institutions to execute a coordinated strategy for high power targetry R&D. This collaboration is generating new and useful materials data for application within the accelerator and the fission/fusion communities. I will give an overview of the RaDIATE R&D program and the achievement in the last few years on material studies in support of High Power Targetry development, including results obtained from irradiation test, development of novel materials and the prospective towards future irradiation campaign. A highlight will be given to the results in collaboration with our colleagues from J-PARC.

Pellemoine, Frederique↗

Vibration-based health characterization of multiple IMUs in UAV applications

Inertial measurement units (IMUs) are vital in UAV navigation for vehicle attitude and position estimation, especially in the frequently-occurring case of temporary loss of GPS capabilities. Degradation in these units could yield inaccurate position estimates, resulting in incorrect input for vehicle control systems. A wide variety of these units exist to meet the needs of UAV operators, general aviation, and military vehicles. In recent decades, lightweight and inexpensive MEMS sensors have grown in popularity with respect to UAVs. Studies into the failure modes of MEMS devices suggest that vibration is one of the leading causes of MEMS degradation. MEMS sensors are generally encased in their own hermetic packaging, as their small size and sensitivity cause them to be particularly vulnerable to air damping and particulate contamination when exposed. Exposure to excessive vibration can cause cracking in this packaging as well as damage to connecting electronics, with recorded results that cause sensors to act outside of their specifications, potentially providing unreliable input to controllers. A prior study from the Politecnico di Torino looked into the degradation of MEMS IMUs, specifically the AXIS-AIS402, for aerospace and vibrating environments. In the study, the authors found that after exposing MEMS IMUs to simulated vibrations from working conditions of aerospace applications, the sensors showed increased noise and increased bias instability. At NASA Ames, several widely-used MEMS IMUs were selected for a new IMU degradation study, comparing accelerometer performance before and after exposure to similar levels of vibration simulating aerospace conditions. The IMUs were selected from the Pixhawk autopilot systems, hobby sUAS, or prior experimental studies at NASA. Additionally, the industrial grade VectorNav-100 IMU was selected as a ground truth reference point to which the performance of the test sensors can be compared. In the study, each sensor is exposed to functional levels of UAV vibration as replicated on a single-frequency vibratory table in the NASA Ames SHARP Laboratory, and each accelerometer is characterized for bias, drift, and noise characteristics both before and after vibratory exposure. The focus of this study is to monitor the health of the IMU sensors and determine if sensor degradation can be detected from output error and frequency spectrum analysis, rather than from microscopic examination of the sensors. In this case, sensor degradation and faulty data can be more easily detectable by non-experts hoping to use these sensors as an important piece of an integrated package. In addition, specific sensor degradation modes potentially leading to in-flight hazards could be identified, such as accelerated levels of drift and altered temperature response. The overall goal of this work is to increase levels of safety for future users of these sensors and to provide a clear analysis of sensor limitations currently lacking in most sensor specification documentation.

IMUs↗

An Investigation of Catastrophic Failure in Solid-State Lamps Exposed to Harsh Environment Operational Conditions

Today’s lighting technology is steadily becoming more energy efficient and less toxic to the environment since the passing of the Energy Independence and Security Act of 2007 (EISA) [1]. EISA has mandated a higher energy efficiency standard for lighting products and the phase out of the common incandescent lamp. This has led lighting manufacturers to pursue solid-state lighting (SSL) technologies for consumer lighting applications. However, two major roadblocks are hindering the transition process to SSL lamps: cost and quality. In order to cut cost, manufactures are moving towards cheaper packaging materials and a variety of package architecture construction techniques which may potentially erode the quality of the lamp and reduce its survivability in everyday applications. Typically, SSL lamps are given product lifetimes of over twenty years based off of the IES TM-21-11 lighting standard which does not include moisture effects or large operational temperatures [2]. A group of recently released off-the-shelf lamps have undergone a steady-state temperature humidity bias life test of 85°C/85%RH (85/85) to investigate the reliability in harsh environment applications. The lack of accelerated test methods for lamps to assess reliability prior to introduction into the marketplace does not exist in literature. There is a need for SSL physics based models for the assessment and prediction of a lamp’s lifetime which is being spearheaded by the DOE [3]. In order to be fully accepted in the marketplace, SSL lamps must be able to perform similarly to incandescent lamps in these environments, as well as live up to the lifetime claims of manufacturers. A lamp’s package architecture must be designed with performance factors in mind, as well as address some of the known and published package related failure mechanisms, such as carbonization of the encapsulant material, delamination, encapsulant yellowing, lens cracking, and phosphor thermal quenching [4]. Each failure mechanism produces the similar failure mode of lumen degradation predominately due to two contributing factors: high junction temperature and moisture ingress. The current state-of-the-art has focused on individual areas of the lamp, such as the LED chip, substrate material, electrical driver design and thermal management techniques. [5] – [16] Looking at the lamp as a whole is a novel approach and has not been seen before in literature. This work followed the JEDEC standard JESD22-A101C of 85/85 with a one hour interval of applied voltage followed by a one hour interval of no applied voltage [17]. This test was performed continuously for each SSL lamp until it became nonoperational, i.e. did not turn on. Periodically, photometric measurements were taken following the IES LM-79-08 standard at room temperature using an integrating sphere, a spectrometer, and lighting software. The overall health of the SSL lamps was assed using the relative luminous flux (RLF), correlated color temperature (CCT) and the color difference (Δu'v') using the Euclidean distance of the CIE 1976 color space coordinates. Finally, a Weibull analysis was completed to compare the characteristic lifetime of the SSL lamp to the actual rated lifetime. An important result from this work shows that the rated lifetime does not come close to the actual lifetime when the SSL lamps are used in a harsh humid environment which is fairly common in outdoor applications across the U.S. Also, the photometric results are presented for the entire lifetime of each SSL lamp under test.

54 ENVIRONMENTAL SCIENCES↗

Sensorimotor Countermeasures

Exploration class missions will include multiple transitions between gravitational environments, sometimes after long periods in microgravity, which will impact the neurovestibular system and sensorimotor capabilities. New countermeasures and assessment tools are needed to enhance preflight disorientation training, maintain inflight physical performance, and accelerate recovery following transitions between gravity environments so that crew are enabled to perform critical exploration mission tasks. The Sensorimotor Countermeasures capability area encompasses three projects. 1) The Upright Proprioception Retention via Inflight Training and Evaluation (UPRITE) system is being developed as an in-flight countermeasure that will mitigate the degradation of balance control mechanisms, which will improve post-flight postural stability. The development of such a countermeasure is not simply a matter of adapting a ground-based training program for spaceflight. The way that we control balance in a gravitational environment cannot be duplicated in 0g. Therefore, the UPRITE system challenges proprioception and tactile function using a 0g configuration. The steps to develop the countermeasure have been broken into seven phases: training type, controllable board factors, protocol development, 0g hardware test, training efficacy, ISS hardware demonstration, and countermeasure verification. 2) Unobtrusive Monitoring Tools and Operational Assessments (aka Head/Body Assessments) are being developed to quantify crew member sensorimotor adaptation following gravitational transitions. Three areas are needed in this development 1) explore, develop, and validate unobtrusive monitoring tools, 2) define sensorimotor performance metrics, and 3) explore capabilities to enhance sensorimotor assessment tasks for operational use and validate assessment tasks via high-fidelity analogs. 3) The Spatial Disorientation Trainer is being developed as a portable training capability to simulate the performance of landing and recovery type tasks while experiencing vertigo due to post-flight vestibular alterations. These simulations can be used 1) across research studies investigating the impacts of vestibular disruption on operational performance/assessments, 2) to train astronauts for upcoming spaceflight missions, and 3) to educate space medicine and operational personnel prior to providing post-flight support.

Scott Jonathan Wood↗

RF optimization and analysis of the 805-MHz cavity for the MuCool program using ACE3P

An 805 MHz pillbox cavity tested at Fermilab's MTA facility showed significant degradation in gradient when operated in a several Tesla solenoidal magnetic field. We have used the advanced ACE3P simulation codes developed at SLAC to study the cavity dark current and multipacting characteristics to gain more insight into the gradient limitations. We also checked whether there is an optimal cavity length that minimizes the dark current impact energy. Finally, we have improved on the cavity design, significantly lowering the fields outside the beam area. These and other results are presented in this paper.

43 PARTICLE ACCELERATORS↗

Application of Peracetic Acid in Poultry Processing: Effects of Treatment Dynamics and Emerging Risk of Resistance Development in Salmonella spp.

Nontyphoidal Salmonella is a leading cause of foodborne illness, with poultry representing a major source. Peracetic acid (PAA), a widely adopted antimicrobial in poultry processing, offers advantages over traditional disinfectants but has sparked interest in its combined use with other antimicrobials and potential resistance. This review evaluates the efficacy of PAA in mitigating Salmonella in combination with other food-grade antimicrobials, explores possible synergism, efficacy under varying treatment parameters, resistance development against PAA, and its role in resistance evolution. While PAA demonstrates broad-spectrum efficacy, its performance varies with environmental parameters; higher temperatures generally enhance antimicrobial action but also accelerate PAA degradation. Organic matter diminishes PAA efficacy by reactive quenching. Variability in concentration and contact time further influences outcomes. Despite its oxidative mode of action and presumed low risk for resistance, emerging studies indicate that Salmonella can develop adaptive tolerance and potential cross/coresistance following repeated or sublethal exposure to PAA. These adaptations may involve genetic upregulation of oxidative stress response pathways, efflux systems, and modifications in cell membrane integrity, raising concerns about the long-term sustainability of PAA use. Additionally, combinatorial treatments (e.g., PAA with UV-C, enzymes, or organic acids) show promise in enhancing efficacy while mitigating resistance risks. Despite recognition of PAA's safety and effectiveness, knowledge gaps remain regarding standardized resistance definitions, serotype-specific tolerance, and optimal intervention strategies in commercial settings. Therefore, there is a need for standardized testing protocols, robust studies on potential resistance, and further exploration of synergistic PAA applications to ensure sustained poultry product safety and public health protection.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Durable Mn-Based PGM-Free Catalysts for Polymer Electrolyte Membrane Fuel Cells

This proposed project aims to develop and evaluate novel manganese based, nitrogen-derived, PGM-free electrocatalysts (denoted as Mn-N-C) to fully address the membrane electrolyte assemblies (MEA)’s ionomer degradation issue resulting from iron. Four thrusts will be pursed in this proposed project. First, advanced first-principles computation methods will be employed to accelerate the rational catalyst design and synthesis. Second, an effective hydro-gel method will be used to maximize atomic Mn active sites embedded in carbon matrix. Next, state-of-the art methods in fuel cell companies will be used to fabricate MEAs containing the Mn-N-C catalysts. Finally, industry standards will be rigorously followed to evaluate fuel cell performance and durability of the Mn-N-C catalysts. With successful completion of the project, it is expected that the following outcomes will be achieved. (1) A set of MEAs containing the Mn-N-C catalysts and with active area large than 50 cm 2 for independent testing, (2) testing results demonstrating that the MEAs of Mn-N-C catalysts have mass activity of 0.044 A/cm 2 at 0.9 VIR-free and H 2 /air performance of 0.50 V at 1.0 A/cm 2 ; (3) fundamental understanding of the composition-structure-property relation of the PGM-free Mn- N-C catalysts, and (4) computational data, measurement data, and publications deposited into the database of ElectroCat Consortium.

08 HYDROGEN↗

A novel electron gun for inline MRI-linac configurations

Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0.5 T magnet without capture efficiency reduction below the experimental value in zero field. In this range of linac displacements, the electron beam generated by the new gun geometry is more effectively injected into the linac in the presence of an external magnetic field, resulting in approximately 20% increase of the target current compared to the original gun geometry behavior at zero field. The new gun geometry can generate and accelerate electron beams in external magnetic fields without current loss for fields higher than 0.11 T. The new electron-gun geometry is robust enough to function in the fringe fields of the other two magnets with a target current loss of no more than 16% with respect to the current obtained with no external magnetic fields. Conclusions: In this work, a specially designed electron gun was presented which can operate in the presence of axisymmetric strong magnetic fringe fields of MRI magnets. Computer simulations show that the electron gun can produce high quality beams which can be injected into a straight through linac such as Varian 600C and accelerated with more efficiency in the presence of the external magnetic fields. Also, the new configuration allows linac displacements along the magnet axis in a range equal to the diameter of the imaging spherical volume of the magnet under consideration. The new electron gun-linac system can function in the fringe field of a MRI magnet if the field strength at the cathode position is higher than 0.11 T. The capture efficiency of the linac depends on the magnetic field strength and the field gradient. The higher the gradient the better the capture efficiency. The capture efficiency does not degrade more than 16%.

43 PARTICLE ACCELERATORS↗

Intrinsically stable organic solar cells under high-intensity illumination

Organic photovoltaic cells are now approaching commercially viable efficiencies, particularly for applications that make use of their unique potential for flexibility and semitransparency. However, their reliability remains a major concern, as even the most stable devices reported so far degrade within only a few years. This has led to the belief that short operational lifetimes are an intrinsic disadvantage of devices that are fabricated using weakly bonded organic materials—an idea that persists despite the rapid growth and acceptance of organic light-emitting devices, which can achieve lifetimes of several million hours9. Here we study an extremely stable class of thermally evaporated single-junction organic photovoltaic cells. We accelerated the aging process by exposing the packaged cells to white-light illumination intensities of up to 37 Suns. The cells maintained more than 87 percent of their starting efficiency after exposure for more than 68 days. The degradation rate increases superlinearly with intensity, leading to an extrapolated intrinsic lifetime, T 80 , of more than 4.9 × 10 7 hours, where T 80 is the time taken for the power conversion efficiency to decrease to 80 per cent of its initial value. This is equivalent to 27,000 years outdoors. Additionally, we subjected a second group of organic photovoltaic cells to 20 Suns of ultraviolet illumination (centred at 365 nanometres) for 848 hours, a dose that would take 1.7 × 10 4 hours (9.3 years) to accumulate outdoors. No efficiency loss was observed over the duration of the test. Overall, we find that organic solar cells packaged in an inert atmosphere can be extremely stable, which is promising for their future use as a practical energy generation technology.

14 SOLAR ENERGY↗

Next Generation Anodes for Lithium Ion Batteries: Thermodynamic Understanding and Abuse Performance.

As we develop new materials to increase performance of lithium ion batteries for electric vehicles, the impact of potential safety and reliability issues become increasingly important. In addition to electrochemical performance increases (capacity, energy, cycle life, etc.), there are a variety of materials advancements that can be made to improve lithium-ion battery safety. Issues including energetic thermal runaway, electrolyte decomposition and flammability, anode SEI stability, and cell-level abuse tolerance behavior. Introduction of a next generation materials, such as silicon based anode, requires a full understanding of the abuse response and degradation mechanisms for these anodes. This work aims to understand the breakdown of these materials during abuse conditions in order to develop an inherently safe power source for our next generation electric vehicles. The effect of materials level changes (electrolytes, additives, silicon particle size, silicon loading, etc.) to cell level abuse response and runaway reactions will be determined using several techniques. Experimentation will start with base material evaluations in coin cells and overall runaway energy will be evaluated using techniques such as differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and accelerating rate calorimetry (ARC). The goal is to understand the effect of materials parameters on the runaway reactions, which can then be correlated to the response seen on larger cells (18650). Experiments conducted showed that there was significant response from these electrodes. Efforts to minimize risk during testing were taken by development of a smaller capacity cylindrical design in order to quantify materials decision and how they manifest during abuse response.

25 ENERGY STORAGE↗

Fabrication and Testing of a Prototype RF-Dipole Crabbing Cavity

Crabbing cavities are essential in particle colliders to compensate the luminosity degradation due to beam collision at a crossing angle. The 952.6 MHz 2-cell rf-dipole crabbing cavity system was proposed for the Jef-ferson Lab Electron-Ion Collider to restore the head-on collisions of electron and proton bunches at the interac-tion point. A prototype cavity was designed and devel-oped to demonstrate the performance of multi-cell rf-dipole structures. This paper presents the fabrication pro-cess and cold test results of the first 2-cell rf-dipole proto-type cavity.

43 PARTICLE ACCELERATORS↗