Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “55”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Diversity of Chemical Bonding and Oxidation States in MS 4 Molecules of Group 8 Elements

The geometric and electronic ground-state structures of six MS 4 molecules (M = group-8 metals Fe, Ru, Os, Hs, Sm, and Pu) have been studied by using quantum-chemical density-functional and correlated wave-function approaches. The MS 4 species are compared to analogous MO 4 species recently investi-gated (Inorg. Chem. 2016, 55: 4616). Metal oxidation state (MOS) of high value VIII appears in low- spin singlet Td geometric species (Os,Hs)S 4 and (Ru,Os,Hs)O 4 , whereas low MOS=II appears in high- spin septet D 2d species Fe(S 2 ) 2 and (slightly excited) metastable Fe(O 2 ) 2 . The ground states of all other molecules have intermediate MOS values, containing S 2- , S 2 2- , S2 1- (and resp. O 2- -, O 1- , O 2 2- , O 2 1- ) ligands, bonded by ionic, covalent and correlative contributions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature-dependent Battery Performance of a Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT Cathode and In-situ Heat Generation on Cycling

Excellent structural stability, high operating voltage, and high capacity have made Na 3 V 2 (PO 4 ) 2 F 3 a promising cathode material for sodium-ion batteries. However, high-temperature battery performances and heat generation measurements have not been systematically reported yet. Carbon-coated Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT (multi-walled carbon nanotube) samples are fabricated by a hydrothermal-assisted sol-gel method and the electrochemical performances are evaluated at three different temperatures (25, 45, and 55 °C). Furthermore, the well-crystallized Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT samples exhibit good cycling stability at both low and high temperatures; they deliver an initial discharge capacity of 120–125 mAhg -1 at a 1 C rate with a retention of 53 % capacity after 1,400 cycles with 99 % columbic efficiency. The half-cell delivers a capacity of 100 mAhg -1 even at a high rate of 10 C at room temperature. Furthermore, the Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT samples show good long-term durability; the capacity loss is an average of 0.05 % per cycle at a 1 C rate at 55 °C. Additionally, ionic diffusivity and charge transfer resistance are evaluated as functions of state of charge, and they explain the high electrochemical performance of the Na 3 V 2 (PO 4 ) 2 F 3 @MWCNT samples. In-situ heat generation measurements reveal reversible results upon cycling owing to the high structural stability of the material. Excellent electrochemical performances are also demonstrated in the full-cell configuration with hard carbon as well as antimony Sb/C anodes.

25 ENERGY STORAGE↗

Degradation in Photovoltaic Encapsulant Transmittance: Results of the Second PVQAT TG5 Artificial Weathering Study

The optical degradation of encapsulants from ultraviolet (UV) radiation has historically resulted in a significant loss in performance throughout the life of a photovoltaic (PV) module. International Electrotechnical Commission (IEC) test methods have recently been developed to screen for PV encapsulants prone to loss in optical performance. The present study was performed to benchmark polymeric packaging materials relative to IEC 62788-1-4 (covering the measurement of optical transmittance) and IEC 62788-1-7 (on the durability of transmittance), provide feedback toward improvement of the methods, and develop insight regarding optical degradation. Contemporary materials were examined, including poly(ethylene-co-vinyl acetate) (EVA), thermoplastic polyolefin (TPO), polyolefin elastomer (POE), and polyvinyl butyral (PVB) encapsulants; a poly(ethene-co-tetrafluoroethene)/poly(ethylene terephthalate) (ETFE/PET) transparent backsheet; and a polystyrene (PS) working reference material. The use of silica-, specialty-, and rolled-glass was also compared in laminated coupons. Specimen size was separately examined from 2.5 to 12.5 cm. Weathering was performed with a xenon source, using IEC TS 62788-7-2 methods A2, A3, A4, and A5 (chamber temperature of 55 degrees C, 65 degrees C, 75 degrees C, or 85 degrees C), respectively. Characterizations were made using a UV-visible-near-infrared (UV-VIS-NIR) spectrophotometer (transmittance and reflectance, with and without an integrating sphere), a UV-VIS fluorescence spectrophotometer, a camera, and an optical microscope. Performance was analyzed, including solar weighted transmittance, yellowness index, UV cut-off wavelength, and haze (scattering). Separate Arrhenius analyses were performed to assess retention of transmittance and changes in yellowness index. The activation energy for both characteristics was found to range from 15-80 kJ mol-1, with an average of 48 kJ mol-1, similar to the average of 45 kJ mol-1 identified in the previous international PV Quality Assurance Task Force (PVQAT) Task Group 5 (TG5) study of more traditional encapsulants. The separate degradation modes of discoloration and scattering were distinguished in the encapsulants using a comprehensive spectral characterization. Based on these results, the IEC 62788-1-7 pass/fail criteria of 5% change in transmittance was confirmed to identify a known bad encapsulant.

durability↗

How Safe is Bilateral Internal Iliac Artery Embolization Prior to EVAR?

Purpose. To assess the outcomes of patients after bilateral internal iliac artery (IIA) embolization prior to endovascular aneurysm repair (EVAR). Methods. Thirty-nine patients (age range 55-88 years, mean 72.5 years; 2 women) underwent IIA embolization/occlusion before EVAR. There were 28 patients with aorto-biiliac aneurysms and 6 with bilateral common iliac artery (CIA) aneurysms. Five patients with unilateral CIA aneurysms had previous surgical ligation of the contralateral IIA or inadvertent covering by the stent-graft of the contralateral IIA origin. Outcomes were assessed by clinical follow-up. Results. Severe ischemic complications were limited to spinal cord ischemia in 1 patient (3%) who developed paraparesis following EVAR. No other severe ischemic complications such as buttock necrosis, or bowel or bladder ischemia, occurred. Buttock and/or thigh claudication occurred in 12 patients (31%) and persisted beyond 1 year in 3 patients (9%). Sexual dysfunction occurred in 2 patients (5%). Patients who underwent simultaneous embolization had a 25% (3/12) ischemic complication rate versus 41% (11/27) in those with sequential embolization (p = 0.48). Embolization limited to the main trunk of the IIA resulted in a significantly reduced ischemic complication rate of 16% (3/19) versus 55% (11/20) of patients who had a more distal embolization of the IIA (p = 0.019, Fisher's exact test). Conclusion. Severe complications after bilateral IIA embolization are uncommon. Although buttock/thigh claudication occurs in around 30% of patients soon after the procedure, this resolves in the majority after 1 year. There is no obvious benefit for sequential versus simultaneous IIA embolization in our series. Occlusion of the proximal IIA trunk is associated with reduced complications compared with occlusion of the distal IIA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Radiofrequency Ablation for the Treatment of Unresectable Recurrent Non-Small-Cell Lung Cancer After Surgical Intervention

Purpose: A retrospective evaluation was done of clinical utility of lung radiofrequency (RF) ablation in recurrent non-small-cell lung cancer (NSCLC) after surgical intervention. Methods: During May 2003 to October 2010, 44 consecutive patients (26 male and 18 female) received curative lung RF ablation for 51 recurrent NSCLC (mean diameter 1.7 {+-} 0.9 cm, range 0.6 to 4.0) after surgical intervention. Safety, tumor progression rate, overall survival, and recurrence-free survival were evaluated. Prognostic factors were evaluated in multivariate analysis. Results: A total of 55 lung RF sessions were performed. Pneumothorax requiring pluerosclerosis (n = 2) and surgical suture (n = 1) were the only grade 3 or 4 adverse events (5.5%, 3 of 55). During mean follow-up of 28.6 {+-} 20.3 months (range 1 to 98), local tumor progression was found in 5 patients (11.4%, 5 of 44). The 1-, 3-, and 5-year overall survival rates were 97.7, 72.9, and 55.7%, respectively. The 1- and 3-year recurrence-free survival rates were 76.7 and 41.1%, respectively. Tumor size and sex were independent significant prognostic factors in multivariate analysis. The 5-year survival rates were 73.3% in 18 women and 60.5% in 38 patients who had small tumors measuring {<=}3 cm. Conclusion: Our results suggest that lung RF ablation is a safe and useful therapeutic option for obtaining long-term survival in treated patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcome after Radiofrequency Ablation of Sarcoma Lung Metastases

Purpose: Resection is the mainstay of management in patients with sarcoma lung metastases, but there is a limit to how many resections can be performed. Some patients with inoperable disease have small-volume lung metastases that are amenable to thermal ablation. We report our results after radiofrequency ablation (RFA). Methods: This is a retrospective study of patients treated from 2007 to 2012 in whom the intention was to treat all sites of disease and who had a minimum CT follow-up of 4 months. Treatment was performed under general anesthesia/conscious sedation using cool-tip RFA. Follow-up CT scans were analyzed for local control. Primary tumor type, location, grade, disease-free interval, prior resection/chemotherapy, number and size of lung tumors, uni- or bilateral disease, complications, and overall and progression-free survival were recorded. Results: Twenty-two patients [15 women; median age 48 (range 10–78) years] with 55 lung metastases were treated in 30 sessions. Mean and median tumor size and initial number were 0.9 cm and 0.7 (range 0.5–2) cm, and 2.5 and 1 (1–7) respectively. Median CT and clinical follow-up were 12 (4–54) and 20 (8–63) months, respectively. Primary local control rate was 52 of 55 (95 %). There were 2 of 30 (6.6 %) Common Terminology Criteria grade 3 complications with no long-term sequelae. Mean (median not reached) and 2- and 3-year overall survival were 51 months, and 94 and 85 %. Median and 1- and 2-year progression-free survival were 12 months, and 53 and 23 %. Prior disease-free interval was the only significant factor to affect overall survival. Conclusion: RFA is a safe and effective treatment for patients with small-volume sarcoma metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Retrospective Comparison of Ultrasound-Assisted Catheter-Directed Thrombolysis and Catheter-Directed Thrombolysis Alone for Treatment of Proximal Deep Vein Thrombosis

BackgroundRecent studies have suggested that catheter-directed thrombolysis (CDT) reduces development of post-thrombotic syndrome (PTS). Ultrasound-assisted CDT (USCDT) might enhance the efficiency of thrombolysis. We aimed to compare USCDT with CDT on efficacy, safety, development of PTS, and quality of life after long-term follow-up.MethodsWe describe a retrospective case series of 94 consecutive patients admitted with iliofemoral or more proximal deep vein thrombosis (DVT) to the University Hospital from 2002 to 2011, treated either with CDT or USCDT. Scheduled follow-up visits took place between April 2013 and January 2014. Venography measured the degree of residual luminal obstruction of the affected veins. Each patient completed the Short Form 36-item health survey assessment and the Venous Insufficiency Epidemiological and Economic Study-Quality of Life/Symptoms questionnaires. PTS was assessed using the Villalta scale.ResultsRisk factors of DVT were equally distributed between groups. In the USCDT group, we observed a significant decline in the duration of thrombolytic treatment (<48 h: 27 vs. 10 %), shortened hospital stay (median 6.0 days (IQR 5.0–9.0) vs. 8.0 (IQR 5.8–12.0)), and less implantation of (intravenous) stents (30 vs. 55 %). There was no difference in patency (76 vs. 79 % fully patent), prevalence of PTS (52 vs. 55 %), or quality of life between groups after long-term follow-up (median 65 months, range: 15–141).ConclusionsIn this observational study, USCDT was associated with shortened treatment duration, shorter hospital stay, and less intravenous stenting, compared to CDT alone without affecting the long-term prevalence of PTS or quality of life.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hemorrhagic Complications of Percutaneous Cryoablation for Renal Tumors: Results from a 7-year Prospective Study

PurposeCryoablation of renal tumors is assumed to have a higher risk of hemorrhagic complications compared to other ablative modalities. Our purpose was to establish the exact risk and to identify hemorrhagic risk factors.Materials and MethodsThis IRB approved, 7-year prospective study included 261 renal cryoablations. Procedures were under conscious sedation and CT guidance. Pre- and postablation CT was obtained, and hemorrhagic complications were CTCAE tabulated. Age, gender, tumor size, histology, and probes number were tested based on averages or proportions using their exact permutation distribution. “High-risk” subgroups (those exceeding the thresholds of all variables) were tested for each variable alone, and for all combinations of variable threshold values. We compared the subgroup with the best PPV using one variable, with the subgroup with the best PPV using all variables (McNemmar test).ResultsThe hemorrhagic complication rate was 3.5 %. Four patients required transfusions, two required emergent angiograms, one required both a transfusion and angiogram, and two required bladder irrigation for outlet obstruction. Perirenal space hemorrhage was more clinically significant than elsewhere. Univariate risks were tumor size >2 cm, number of probes >2, and malignant histology (P = 0.005, 0.002, and 0.033, respectively). Multivariate analysis showed that patients >55 years with malignant tumors >2 cm requiring 2 or more probes yielded the highest PPV (7.5 %).ConclusionsAlthough older patients (>55 years old) with larger (>2 cm), malignant tumors have an increased risk of hemorrhagic complications, the low PPV does not support the routine use of embolization. Percutaneous cryoablation has a 3.5 % risk of significant hemorrhage, similar to that reported for other types of renal ablative modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Growth of organized flow coherent motions within a single-stream shear layer: 4D-PTV measurements

Abstract This study investigates the evolution of a single-stream shear layer (SSSL) originating from a wall boundary layer past a backward-facing step. Utilizing a time-resolved 3D-Particle Tracking Velocimetry (4D-PTV) technique, we track the trajectories of fluorescent particles to gain insight into the flow characteristics of the SSSL. A compact water tunnel facility ( $$\textrm{Re}_\tau =1\,240$$ Re τ = 1 240 ) is fabricated to obtain an SSSL with a perpendicular slow entrainment stream past the separation edge. A hybrid interpolation approach that combines ensemble binning and Gaussian weighting is implemented to derive minimally filtered mean and instantaneous lower- and higher-order flow field parameters. Spanwise-dominant coherent motion accompanied by finer flow scales is observed to grow due to flow entrainment through “nibbling” actions of small-scale vortices, “engulfing” by large-scale vortices, and vortex pairing events. Furthermore, the non-zero-speed stream edge grows relatively faster than the zero-speed stream edge, showing a strong asymmetry in mixing composition across a mixing layer. The SSSL reaches self-similarity at a streamwise distance of $$\approx 55\,\theta _{0}$$ ≈ 55 θ 0 , where $$\theta _0$$ θ 0 is the initial momentum thickness from the separation edge, i.e., considerably shorter than reported in previous studies. A literature comparison of growth rate parameters raises intriguing questions regarding a potential inclusive growth scaling unifying the free shear layers. A turbulent kinetic energy (TKE) budget analysis reveals a negative production region immediately downstream of the separation edge attributed to a large positive streamwise gradient of streamwise velocity. In the self-similar region, the phase-averaged flow mapping demonstrates a larger concentration of turbulence production rate around the outer edges of spanwise vortices, specifically at the intersection of braids and vortices. Furthermore, a spatial separation exists in the regions of peak production and dissipation rates within the vortex core region favoring dissipation. The braids exhibit a larger concentration of turbulence diffusion rates, indicating their function as a conduit for exchanging turbulence between neighboring coherent motions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Decadal carbon decomposition dynamics in three peatlands in Northern Minnesota

The uppermost portion of the peat profile, an area of active diagenetic processes, is exceedingly important for understanding peatland dynamics and the diagenesis and geochemistry of atmospherically-deposited materials. In this study, we investigated high resolution carbon (C) accrual and peat decomposition rates at two Sphagnum-rich ombrotrophic bogs and one fen in northern Minnesota, USA by analyzing 1 cm increments from 30 cm thick intact frozen blocks of peat soil. We conducted radiocarbon analysis of Sphagnum cellulose to determine peat age and net C accumulation at each depth interval. Calibrated peat ages were determined using CALIBomb and a compilation of calibration datasets for the pre-bomb period. We fit data with a negative exponential accumulation model and used model-derived parameters to estimate net primary productivity (NPP) and a peat decomposition rate constant k. FTIR spectroscopy and C:N were used to derive humification indices and to chemically characterize the peat. NPP ranged from 180 to 266 g C m -2 year -1 , k ranged from 0.015 to 0.019 year -1 . Net C accumulation rates ranged from 112 to 174 g C m -2 year -1 at 25 years and 70 to 113 g C m -2 year-1 at 50 years. Mass loss was up to 55% during the first 50 years of peat accumulation. Decomposition is greater at depth in the bogs—where 25 cm of peat correspond to 55 years of peat accumulation—than in the fen, where peat age is approximately 25 years at 25 cm depth. Lastly, information on fine-scale variations in peat mass decomposition and loss across ombrotrophic bogs and a fen help interpret other diagenetic processes in peatlands.

54 ENVIRONMENTAL SCIENCES↗

Modeling delayed thermal runaway in nitric acid-soaked cat litter mixed with radioactive waste

Thermal ignition of radioactive waste within a 55-gallon drum was simulated by using a pressure-dependent waste decomposition model (Hobbs et al. in Process Saf Environ Prot https://doi.org/10.1016/j.psep.2022.09.047, 2022) calibrated with data from full-scale drum experiments (Parker et al. in The thermolytic response of a surrogate RNS waste mixture at the drum scale. Los Alamos National Laboratory Report LA-UR-16-21760, 2016) and validated with experiments from multiple laboratories (Hobbs et al. in Thermal analysis of aged nitric acid-soaked kitty litter in TRU waste drums-23370.WM2023 Conference, Phoenix, AZ, 2023). The acceleration of nitric acid chemistry reacting with an organic cat litter leading to thermal ignition was likely triggered by a restricted vent in the drum. Here, we address whether the form of the rate equation in (Hobbs et al. in Process Saf Environ Prot https://doi.org/10.1016/j.psep.2022.09.047, 2022) is sufficient to extrapolate thermal ignition within aged drums of similar content that have been stored in Texas for over nine years by investigating four different reaction rate forms for waste decomposition. A critical reaction rate reduction analysis is performed on each of these models to determine if delayed thermal runaway within vented aged waste is possible after nine years. We found that a pressure-dependent first-order rate expression not only predicted the accidental ignition of the waste drum, but the form also matches multiple experiments from different laboratories. Even though the waste composition decreases over time, the model predicts that acceleration leading to thermal runaway is possible if the waste is confined, even after 9 years. In conclusion, waste containing oxidizers such as nitric acid should not be mixed with organic adsorbents, especially if the waste is confined.

cookoff↗

Influence of bath temperatures on physical and electrical properties of potentiostatically deposited Cu{sub 2}O thin films for heterojunction solar cell applications

In the present work, the influence of bath temperatures on structural, morphological, vibrational, optical, electrical and photo response properties of the electrochemically deposited cuprous oxide (Cu{sub 2}O) thin films on fluorine doped tin oxide substrate is extensively investigated with the help of X-ray diffraction (XRD), scanning electron microscopy (SEM), Micro Raman spectroscopy, photo luminescence (PL) spectroscopy, UV–visible spectroscopy, LCR measurement, Keithley 4200 semiconductor characterization system respectively. XRD patterns reveal that the deposited Cu{sub 2}O films have cubic structure grown along the preferential (111) orientation and the film deposited at 40 °C shows better crystalline nature when compared at 55 and 70 °C. The micro structural properties of films such as crystallite size (D), dislocation density (δ), micro strain (ε) and stacking fault probability (α) were calculated and discussed in detail. SEM displays a well-defined three side pyramid shaped morphology for the film deposited at 40 °C. Micro Raman and PL spectra reveal the film deposited at 40 °C by being better crystalline at a higher acceptor concentration. UV–Visible study shows that the optical energy band gap increases from 2.05 to 2.17 eV with an increase in bath temperature from 40 to 70 °C. The frequency-temperature dependence of impedance analysis shows a higher electrical conductivity for a film deposited at 40 °C compared to other bath temperatures. I-V measurement illustrates a good photoconductivity response for Cu{sub 2}O thin film deposited at 40 °C compared to films deposited at 55 and 70 °C.

36 MATERIALS SCIENCE↗

Structural investigation and applications of glassy sodium phosphate including the kinetics of dissolution rates and spectral analysis of the prepared samples with a focus on their effects on water treatment

This paper discuss the preparation of the binary system of Phosphate Based Glass (PBG) xP{sub 2}O{sub 5}–(100 − x) Na{sub 2}O mol% and investigates the compositions that form glassy matrix. It is found that x in the range between x = 40–60 mol% and divided in to 5 glass samples (x = 40, 45, 50, 55, 60) and for compositions of 40 > x > 60 no glassy matrix is formed. The intensities of the peak centers of the IR spectra of sodium phosphate glasses and the suggested vibrational modes of structural phosphate chains, terminal groups and tabulated data imply a shift in absorption bands with increasing the Na{sub 2}O mol% content. The amount of bridging phosphorous, shows a maximum value for the glass containing 60 mol% Na{sub 2}O due to the depolymerization of the phosphate matrix with increasing Na{sub 2}O content from 40 to 60 mol% via a breakdown of some terminal bonds (P=O) in the glass network which decreases the bond strength, consequently the peak center is shifted towards lower wave number. Essentially, five compositions of glassy samples were investigated: (x = 40, 45, 50, 55, and 60) mol%. The kinetics of dissolution rate were investigated by two ways: 1—the weight loss data and 2—electrical properties of the solution (pH, Electrical Conductivity) leached by the glass sample in to the deionized water. It is found that with increasing the Na{sub 2}O% content, the pH values, the dissolution rate and the solubility are increasing. It could be noticed that the ionic levels increased with the immersion time and were directly related to the solubility of the glasses. The highest in solubility (x = 40) is the highest in EC and pH values caused by high Na{sub 2}O%. By studying the effect of PBG on the real water medium physical characteristics the following results were achieved: Softening of (Treated drinking water, Nile raw water) by removal of hardness (Ca, Mg) by x = 50; 50% P{sub 2}O{sub 5}–50% Na{sub 2}O, Sequestering and agglomerating of (groundwater, wastewater) of some heavy metals as (Fe, Mn) up to 100% removal by x = 60; 60% P{sub 2}O{sub 5}–40% Na{sub 2}O and the electrical properties (pH, EC) were discussed. Results are assuring the possibility of applying PBG for groundwater treatment of high Fe and Mn content. The data show that municipal groundwater supplies become acceptable according to the guidelines of American Chemistry Council for safe drinking water by using of polyphosphates for water treatment.

54 ENVIRONMENTAL SCIENCES↗

Deposition Height Prediction in Directed Energy Deposition

Using 316L stainless steel as a model material, reduced-order models are developed to predict capture efficiency, deposition height, and site-specific hardness in directed energy deposition. Capture efficiency is predicted over a 15 to 55 pct range using a dimensionless number derived from processing conditions and thermophysical properties. Deposition height is predicted over a 0.3 to 1.3 mm range without in situ sensing or prior training data, using two models based on the same mass and energy-balance principles. Predictions are compared with machine learning approaches. A quantitative relationship links deposition height, primary dendrite arm spacing (PDAS), and hardness: heights of 0.3 to 1.1 mm correspond to PDAS values of 2.7 to 5.1 µm and Vickers hardness (HV) of 160 to 219. Thinner layers cool more rapidly, producing finer microstructures and higher hardness. Samples fabricated with in situ variations in deposition height exhibited up to 55 HV differences between thick and thin regions, demonstrating that local control of deposition height enables predictive, site-specific hardness within a single build. These results establish deposition height prediction as a pathway for a priori process design and property control in directed energy deposition for 316L stainless steel.

Kunkel, William [Univ. of Wisconsin, Madison, WI (↗

Influence of Ca and Sr Addition on Impression Creep Behavior of Mg-4Al-RE Alloy

The impression creep behavior of Mg-4Al-RE-0.8Ca-0.2Sr (AEXJ4110) alloy was investigated under the applied stresses of 55, 75, 95 MPa and the temperatures of 398, 423, 448 K on a special apparatus. The results showed that the microstructure of AEXJ4110 alloy consisted of acicular Al{sub 11}La{sub 3}, granular Al{sub 2}La, bone shape Al{sub 2}Ca and fish-bone shape Al{sub 4}Sr. The impression creep resistance of AE41 alloy was improved by adding Ca and Sr. The primary impression creep depth of AEXJ4110 alloy was increased with increasing applied stress and temperature. The creep strain rates of AEXJ4110 alloy under different stresses and temperatures were a power function of time. The constitutive equation of steady-state impression creep for AEXJ4110 alloy can be written as ε-dot {sub s}=9.71×10{sup −3}(E/T)(σ/E){sup 4.3}exp ((−100.449+3368.98(σ/E))/RT) with stress exponent n 4.3 and creep activation energy Q{sub c} about 100.449 kJ/mol. The impression creep mechanism of AEXJ4110 alloy in the temperature range of 398-448 K and stress range of 55-95 MPa is controlled by dislocation climb dominated by self-diffusion of magnesium atoms impeded by the precipitated phases with high melting temperatures.

36 MATERIALS SCIENCE↗

Relationships between electrical and mechanical dyssynchrony in patients with left bundle branch block and healthy controls

Background: Abnormal electrical activation may cause dyssynchronous left ventricular (LV) contraction. In this study, we characterized and analyzed electrical and mechanical dyssynchrony in patient with left bundle branch block (LBBB) and healthy controls. Methods: Myocardial perfusion imaging (MPI) data from 994 patients were analyzed. Forty-three patient fulfilled criteria for LBBB and 24 for controls. Electrical activation was characterized with vector electrocardiography (VECG) and LV function including mechanical dyssynchrony with ECG-gated MPI phase analysis. Results: QRS duration (QRSd; r = 0.69, P < .001) and a few other VECG parameters correlated significantly with phase bandwidth (phaseBW) representing mechanical dyssynchrony. End-diastolic volume (EDV; r = 0.59, P < .001), ejection fraction and end-systolic volume correlated also with phaseBW. QRSd (β = 0.47, P < .001) and EDV (β = 0.36, P = .001) were independently associated with phaseBW explaining 55% of its variation. Sixty percent of patients with LBBB had significant mechanical dyssynchrony. Those patients had wider QRSd (159 vs 147 ms, P = .013) and larger EDV (144 vs 94 mL, P = .008) than those with synchronous LV contraction. Cut-off values for mechanical dyssynchrony seen in patients with LBBB were QRSd ≥ 165 ms and EDV ≥ 109 mL. Conclusions: Despite obvious conduction abnormality, LBBB is not always accompanied by mechanical dyssynchrony. QRSd and EDV explained 55% of variation seen in phaseBW. These two parameters were statistically different between LBBB cases with and without mechanical dyssynchrony.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Substance P in Solution: Trans-to-Cis Configurational Changes of Penultimate Prolines Initiate Non-enzymatic Peptide Bond Cleavages

We report ion mobility spectrometry and mass spectrometry studies of the non-enzymatic step-by-step degradation of substance P (subP), an 11-residue neuropeptide, with the sequence Arg{sup 1}-Pro{sup 2}-Lys{sup 3}-Pro{sup 4}-Gln{sup 5}-Gln{sup 6}-Phe{sup 7}-Phe{sup 8}-Gly{sup 9}-Leu{sup 10}-Met{sup 11}-NH{sub 2}, in ethanol. At elevated solution temperatures (55 to 75 °C), several reactions are observed, including a protonation event, i.e., [subP+2H]{sup 2+} + H{sup +} → [subP+3H]{sup 3+}, that appears to be regulated by a configurational change and two sequential bond cleavages (the Pro{sup 2}-Lys{sup 3} peptide bond is cleaved to form the smaller nonapeptide Lys{sup 3}-Met{sup 11}-NH{sub 2} [subP{sub (3–11)}], and subsequently, subP{sub (3–11)} is cleaved at the Pro{sup 4}-Gln{sup 5} peptide bond to yield the heptapeptide Gln{sup 5}-Met{sup 11}-NH{sub 2} [subP{sub (5–11)}]). Each of the product peptides [subP{sub (3–11)} and subP{sub (5–11)}] is accompanied by a complementary diketopiperazine (DKP): cyclo-Arg{sup 1}-Pro{sup 2} (cRP) for the first cleavage, and cyclo-Lys{sup 3}-Pro{sup 4} (cKP) for the second. Insight about the mechanism of degradation is obtained by comparing kinetics calculations of trial model mechanisms with experimental data. The best model of our experimental data indicates that the initial cleavage of subP is regulated by a conformational change, likely a trans→cis isomerization of the Arg{sup 1}-Pro{sup 2} peptide bond. The subP{sub (3–11)} product has a long lifetime (t{sub 1/2} ~ 30 h at 55 °C) and appears to transition through several structural intermediates prior to dissociation, suggesting that subP{sub (3–11)} is initially formed with a Lys{sup 3}-trans-Pro{sup 4} peptide bond configuration and that slow trans→cis isomerization regulates the second bond cleavage event as well. From these data and our model mechanisms, we obtain transition state thermochemistry ranging from ΔH{sup ‡} = 41 to 85 kJ mol{sup −1} and ΔS{sup ‡} = − 43 to – 157 J mol{sup −1} K{sup −1} for each step in the reaction. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗