Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Dynamic Dislocation-Defect Analysis and SAXS Study of Nanovoid Formation in Aluminum Alloys

Crystalline defects other than the essential dislocations are produced by dislocation intersections resulting in debris, which can transform into loops, point defects, and/or nanovoids. The stress concentrations ahead of slip clusters promote void formation leading to incipient cracks. To evaluate the progression of these processes during deformation, dynamic dislocation-defect analysis was applied to nominally pure aluminum, Al-Mg, and Al-Cu alloys. In the case of nanovoid formation, small angle X-ray scattering (SAXS) was used to quantitatively assess if the void size and its volume fraction can be determined to directly correlate with the measured thermodynamic response values. The SAXS signal from the nanovoids in nominally pure aluminum is distinctly measurable. On the other hand, thermomechanical processing of even nominally pure aluminum results in the formation of nanoprecipitates, which requires future calibration.

36 MATERIALS SCIENCE↗

Verification of dose distribution for volumetric modulated arc therapy total marrow irradiation in a humanlike phantom

Purpose: Volumetric modulated arc therapy (VMAT) treatment planning studies have been reported to provide good target coverage and organs at risk (OARs) sparing in total marrow irradiation (TMI). A comprehensive dosimetric study simulating the clinical situation as close as possible is a norm in radiotherapy before a technique can be used to treat a patient. Without such a study, it would be difficult to make a reliable and safe clinical transition especially with a technique as complicated as VMAT-TMI. To this end, the dosimetric feasibility of VMAT-TMI technique in terms of treatment planning, delivery efficiency, and the most importantly three dimensional dose distribution accuracy was investigated in this study. The VMAT-TMI dose distribution inside a humanlike Rando phantom was measured and compared to the dose calculated using RapidArc especially in the field junctions and the inhomogeneous tissues including the lungs, which is the dose-limiting organ in TMI. Methods: Three subplans with a total of nine arcs were used to treat the planning target volume (PTV), which was determined as all the bones plus the 3 mm margin. Thermoluminescent detectors (TLDs) were placed at 39 positions throughout the phantom. The measured TLD doses were compared to the calculated plan doses. Planar dose for each arc was verified using mapcheck. Results: TLD readings demonstrated accurate dose delivery, with a median dose difference of 0.5% (range: -4.3% and 6.6%) from the calculated dose in the junctions and in the inhomogeneous medium including the lungs. Conclusions: The results from this study suggest that RapidArc VMAT technique is dosimetrically accurate, safe, and efficient in delivering TMI within clinically acceptable time frame.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-388: Estimating the Radioactivity Inventory of a Cyclotron Based Pencil Beam Proton Therapy Facility

Purpose: Parts of the cyclotron and energy degrader are incidentally activated by protons lost during the acceleration and transport of protons for radiation therapy. An understanding of the radioactive material inventory is needed when regulatory requirements are assessed. Methods: First, the tumor dose and volume is used to determine the required energy deposition. For spot scanning, the tumor length along the beam path determines the number of required energy layers. For each energy layer the energy deposition per proton can be calculated from the residual proton range within the tumor. Assuming a typical layer weighting, an effective energy deposition per proton can then be calculated. The total number of required protons and the number of protons per energy layer can then be calculated. For each energy layer, proton losses in the energy degrader are calculated separately since its transmission efficiency, and hence the amount of protons lost, is energy dependent. The degrader efficiency also determines the number of protons requested from the cyclotron. The cyclotron extraction efficiency allows a calculation of the proton losses within the cyclotron. The saturation activity induced in the cyclotron and the degrader is equal to the production rate R for isotopes whose half-life is shorter that the projected cyclotron life time. R can be calculated from the proton loss rate and published production cross sections. Results: About 1/3 of the saturation activity is produced in the cyclotron and 2/3 in the energy degrader. For a projected case mix and a patient load of 1100 fractions per week at 1.8 Gy per fraction a combined activity of 180 mCi was estimated at saturation. Conclusion: Calculations were used to support to application of a radioactive materials license for the possession of 200 mCi of activity for isotopes with atomic numbers ranging from 1-83.

07 ISOTOPE AND RADIATION SOURCES↗

Poster — Thur Eve — 31: Dosimetric Effect of Respiratory Motion on RapidArc Lung SBRT Treatment Delivered by TrueBeam Linear Accelerator

Volumetric modulated arc therapy (VMAT) allows fast delivery of stereotactic radiotherapy. However, the discrepancies between the calculated and delivered dose distributions due to respiratory motion and dynamic multileaf collimators (MLCs) interplay are not avoidable. The purpose of this study is to investigate RapidArc lung SBRT treatment delivered by the flattening filter-free (FFF) beam and flattened beam with Varian TrueBeam machine. CIRS Dynamic Thorax Phantom with in-house made lung tumor insertion was CT scanned both in free breathing and 4DCT. 4DCT was used to determine the internal target volume. The free breathing CT scan was used for treatment planning. A 5 mm margin was given to ITV to generate a planning target volume. Varian Eclipse treatment planning was used to generate RapidArc plans based on the 6 MV flattened beam and 6MV FFF beam. The prescription dose was 48 Gy in 4 fractions. At least 95% of PTV was covered by the prescribed dose. The RapidArc plans with 6 MV flattened beam and 6MV FFF beam were delivered with Varian TrueBeam machine. The dosimetric measurements were performed with Gafchromic XR-RV3 film, which was placed in the lung tumor insertion. The interplay between the dynamic MLC-based delivery of VMAT and the respiratory motion of the tumor degraded target coverage and created undesired hot or cold dose spots inside the lung tumor. Lung SBRT RapidArc treatments delivered by the FFF beam of TrueBeam linear accelerator is superior to the flattened beam. Further investigation will be performed by Monte Carlo simulation.

60 APPLIED LIFE SCIENCES↗

Sci—Sat AM: Stereo — 06: Dosimetric Comparison of 3D Conformai, Flattened and Flattening Filter-Free TrueBeam RapidArc Planning for Lung SBRT

The major advantages of the VMAT SBRT plans compared to the conventional 3D conformai plan include faster delivery and improved target dose conformity. This study quantifies the dosimetric differences among 3D conformai plan; flattened beam and flattening filter-free (FFF) beam RapidArc Plans for lung SBRT. Five early stage lung cancer patients with various tumor positions and sizes previously treated with 3D non-coplanar SBRT were randomly selected. 4DCT was used for each patient to determine the internal target volume. Abdominal compression was applied to minimize respiratory motion for SBRT patients. For treatment planning, a 5 mm margin was given to the ITV to generate a planning target volume. The prescription dose was 48 Gy in 4 fractions and normalized to 95% of the PTV. Organs at risk (OAR) included spinal cord, esophagus, heart, trachea, bilateral lung, and great vessels. Optimization constraints were set to meet the criteria of the RTOG-0915 protocol. All VMAT plans were optimized with the RapidArc technique using two full arcs in Eclipse treatment planning system. The RapidArc SBRT plans with flattened 6MV beam and 6MV FFF beam were generated and dosimetric results were compared with the previous treated 3D non-coplanar plans. RapidArc plans demonstrated better conformity to target, sharper dose fall-off in normal tissues and lower dose to normal lung and other OARs than the 3D conformai plans. RapidArc SBRT for FFF beam showed comparable target conformity, adequate tumor dose, and clinically acceptable DVHs of OARs to flattened beams and significantly reduced treatment delivery time.

60 APPLIED LIFE SCIENCES↗

SU-E-T-538: Lung SBRT Dosimetric Comparison of 3D Conformal and RapidArc Planning

Purpose: Dose distributions of RapidArc Plan can be quite different from standard 3D conformal radiation therapy. SBRT plans can be optimized with high conformity or mimic the 3D conformal treatment planning with very high dose in the center of the tumor. This study quantifies the dosimetric differences among 3D conformal plan; flattened beam and FFF beam RapidArc Plans for lung SBRT. Methods: Five lung cancer patients treated with 3D non-coplanar SBRT were randomly selected. All the patients were CT scanned with 4DCT to determine the internal target volume. Abdominal compression was applied to minimize respiratory motion for SBRT patients. The prescription dose was 48 Gy in 4 fractions. The PTV coverage was optimized by two groups of objective function: one with high conformity, another mimicking 3D conformal dose distribution with high dose in the center of PTV. Optimization constraints were set to meet the criteria of the RTOG-0915 protocol. All VMAT plans were optimized with the RapidArc technique using four full arcs in Eclipse treatment planning system. The RapidArc SBRT plans with flattened 6MV beam and 6MV FFF beam were generated and dosimetric results were compared with the previous treated 3D non-coplanar plans. Results: All the RapidArc plans with flattened beam and FFF beam had similar results for the PTV and OARs. For the high conformity optimization group, The DVH of PTV exhibited a steep dose fall-off outside the PTV compared to the 3D non-coplanar plan. However, for the group mimicking the 3D conformal target dose distribution, although the PTV is very similar to the 3D conformal plan, the ITV coverage is better than 3D conformal plan. Conclusion: Due to excellent clinical experiences of 3D conformal SBRT treatment, the Rapid Arc optimization mimicking 3D conformal planning may be suggested for clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sci-Fri AM: MRI and Diagnostic Imaging - 02: Quality Improvement: Diagnostic Reference Levels for Interior Health CT exams – L-Spine, Chest/Abdomen/pelvis, Abdomen/Pelvis, Head

Diagnostic Reference Levels are used to optimize patient dose and image quality in the clinical setting. It is assumed that the majority of exams are of diagnostic quality, or the radiologists would request protocol adjustments. By investigating the dose indicator distributions from all scanners, the upper DRL can be set to the 75th percentile of the distribution and a lower DRL can be set to the 10th percentile. Scanners using doses consistently outside the upper/lower DRL range can be adjusted accordingly. 11 CT scanners, all contributing to the American College of Radiology Dose Index Registry (ACR DIR) were used in this study. Dose indicator data were compiled from the ACR DIR data and local DRLs established. Scanners with median doses outside the upper/lower DRL were followed-up with. Using effective dose and exam volumes, collective dose was determined before and after protocol adjustments to evaluate the effect of this quality improvement effort. The quality initiative is complete for L-spine and Chest/Abdomen/Pelvis exams and only initial surveys were completed for Head and Abdomen/Pelvis examsg. Median Scanner Dose reductions were 8.8 and 4.9 % for L-spine and Chest/Abdomen/Pelvis exams, respectively, resulting with collective dose reductions of 0.7 and 3.2 person•Sv/yr. Follow-up is ongoing for Abdomen/Pelvis and Head exams.

60 APPLIED LIFE SCIENCES↗

Technical assessment of compressed hydrogen storage tank systems for automotive applications.

The performance and cost of compressed hydrogen storage tank systems has been assessed and compared to the U.S. Department of Energy (DOE) 2010, 2015, and ultimate targets for automotive applications. The on-board performance and high-volume manufacturing cost were determined for compressed hydrogen tanks with design pressures of 350 bar ({approx}5000 psi) and 700 bar ({approx}10,000 psi) capable of storing 5.6 kg of usable hydrogen. The off-board performance and cost of delivering compressed hydrogen was determined for hydrogen produced by central steam methane reforming (SMR). The main conclusions of the assessment are that the 350-bar compressed storage system has the potential to meet the 2010 and 2015 targets for system gravimetric capacity but will not likely meet any of the system targets for volumetric capacity or cost, given our base case assumptions. The 700-bar compressed storage system has the potential to meet only the 2010 target for system gravimetric capacity and is not likely to meet any of the system targets for volumetric capacity or cost, despite the fact that its volumetric capacity is much higher than that of the 350-bar system. Both the 350-bar and 700-bar systems come close to meeting the Well-to-Tank (WTT) efficiency target, but fall short by about 5%. These results are summarized.

03 NATURAL GAS↗

Nanofiltration Treatment Options for Thermoelectric Power Plant Water Treatment Demands

Nanofiltration (NF) can effectively treat both cooling-tower water and coal-bed methane (CBM) produced waters. NF is an attractive option over conventional reverse osmosis because it requires less power and is less likely to scale. Nanofiltration could help in minimizing water consumption and maximize water usage efficiency of thermoelectric power plants. The power plants could increase the cycles of water recirculation through cooling towers and/or used treated impaired waters. The NF system effectively removed scaling components from cooling-tower recirculating water with an efficiency of > 99% for divalent ions, 78% - 95.8% for monovalent ions and almost 90% for silica and from CBM produced water with efficiency greater than 95% for most constituents including silica. In most cases the NF system worked better than predicted by the ROSA™, a manufacturer’s desalination software used to design systems and predict how well they will work. Theoretical calculations determined that the total volume of water discharged from cooling towers can be reduced by as much as 75% using the continuous NF process compared to traditional recirculating cooling-tower operation. The total volume of water needed for make up could be reduced by as much as 25%. The cost for NF of cooling-tower water is estimated to be $\$$0.50 – $\$$0.90 per per 1,000 gallons. Before the successful use of a NF system in a cooling tower with similar chemistry of this pilot study, the system and pretreatment system must be designed carefully to control scaling in NF unit. In addition, NF treatment of CBM produced water will likely require a pretreatment system to control parafilms, filming agents, iron flocs, coal fines, and biological growth.

Altman, Susan Jeanne↗

EPICS Controlled Collimator for Controlling Beam Sizes in HIPPO

Controlling the beam spot size and shape in a diffraction experiment determines the probed sample volume. The HIPPO - High-Pressure-Preferred Orientation– neutron time-offlight diffractometer is located at the Lujan Neutron Scattering Center in Los Alamos National Laboratories. HIPPO characterizes microstructural parameters, such as phase composition, strains, grain size, or texture, of bulk (cm-sized) samples. In the current setup, the beam spot has a 10 mm diameter. Using a collimator, consisting of two pairs of neutron absorbing boron-nitride slabs, horizontal and vertical dimensions of a rectangular beam spot can be defined. Using the HIPPO robotic sample changer for sample motion, the collimator would enable scanning of e.g. cylindrical samples along the cylinder axis by probing slices of such samples. The project presented here describes implementation of such a collimator, in particular the motion control software. We utilized the EPICS (Experimental Physics Interface and Control System) software interface to integrate the collimator control into the HIPPO instrument control system. Using EPICS, commands are sent to commercial stepper motors that move the beam windows.

43 PARTICLE ACCELERATORS↗

The Role of Grain Boundary Structure and Chemistry in Materials Failure

The project investigated the local mechanical behavior of metal grain boundaries with and without the influence of a segregated alloy element, specifically in the Fe-C alloy system. Local deformation was carried out using nano-indentation with varying indentation-grain boundary geometry and strain rate. Stress relaxation under constant load and strain rate response to stress jumps were used to determine activation energy, activation volume and athermal stress as a function of grain boundary chemistry. The primary accomplishments of the project were (i) resolving the action of the proposed Ashby mechanism of grain boundary hardening from the action of the accepted Hall-Petch mechanism (ii) revealed the relationship between grain boundary chemistry, activation energy and athermal stress.

36 MATERIALS SCIENCE↗

On Two-Phase Pressure and Temperature Equilibration with Mie-Grüneisen Equations of State

In the course of reactive flow modeling, the phases of high explosive (HE) reactants and products introduce additional degrees of freedom to the underlying hydrodynamic equations of compressible reactive fluid mechanics. Hydrodynamic simulations track the bulk (mixture) conservation properties of mass, momentum and energy. When multiple phases are introduced, one must decide on appropriate closure rules to determine the relative phase volumes and energy distribution between the phases. One typical closure is to assume that the phases are in pressure and temperature equilibrium. Here, the requisite equations of p-T equilibration are explored for Mie-Grüneisen Equations of State (EOS). Examples with Davis reactants and Davis products EOSs will be given. The Davis forms are used in both the WSD and AWSD reactive flow models.

42 ENGINEERING↗

The Austin Chalk/Eagle Ford Field Laboratory (ACEFFL)

This project, led by Texas A&M University, developed a science-based field laboratory in the Austin Chalk/Eagle Ford Shale Formation to determine the stimulated reservoir volume created by the fracturing of multiple wells. Utilizing newly developed monitoring solutions, the team delivered comprehensive high-quality field data on the extent and morphologies of productive fractures created from these wells. Advanced field monitoring was complemented by laboratory testing on cores and drill cuttings, and coupled modeling for design, prediction, calibration, and code validation. The Austin Chalk/Eagle Ford Field Laboratory (ACEFFL) was hosted by SM Energy, which provided access to the wells of opportunity.

02 PETROLEUM↗

3013 Fire Test 2020: Post-Test Measurements and Analysis

Sandia National Laboratory conducted fire tests on ten 3013 containers with varying amounts of water. The containers with attached manifolds were sent to Los Alamos National Laboratory for post-test measurements of the plastic deformation, the amount of water remaining on the material post-test and the mass loss. The measurements of the plastic deformation were used to determine the free gas volume in each container and manifold post-test. The disassembly of each container was documented by photographs. The amount of pre-test gas constituents is also reported using data in the Sandia Final Report.

3013 fire test↗

The YNP metagenome project: environmental parameters responsible for microbial distribution in the Yellowstone geothermal ecosystem

The Yellowstone geothermal complex contains over 10,000 diverse geothermal features that host numerous phylogenetically deeply rooted and poorly understood archaea, bacteria, and viruses. Microbial communities in high-temperature environments are generally less diverse than soil, marine, sediment, or lake habitats and therefore offer a tremendous opportunity for studying the structure and function of different model microbial communities using environmental metagenomics. One of the broader goals of this study was to establish linkages among microbial distribution, metabolic potential, and environmental variables. Twenty geochemically distinct geothermal ecosystems representing a broad spectrum of Yellowstone hot-spring environments were used for metagenomic and geochemical analysis and included approximately equal numbers of: (1) phototrophic mats, (2) “filamentous streamer” communities, and (3) archaeal-dominated sediments. The metagenomes were analyzed using a suite of complementary and integrative bioinformatic tools, including phylogenetic and functional analysis of both individual sequence reads and assemblies of predominant phylotypes.This volume identifies major environmental determinants of a large number of thermophilic microbial lineages, many of which have not been fully described in the literature nor previously cultivated to enable functional and genomic analyses. Moreover, protein family abundance comparisons and in-depth analyses of specific genes and metabolic pathways relevant to these hot-spring environments reveal hallmark signatures of metabolic capabilities that parallel the distribution of phylotypes across specific types of geochemical environments.

59 BASIC BIOLOGICAL SCIENCES↗

Implementation and Performance Evaluation of a Community-Scale Adobe Evaporative Cooling Chamber for Vegetable Preservation

The construction of evaporative coolers in remote areas can increase the longevity of vegetables, improving food security and the local economy of small farmers in remote, impoverished communities without access to electricity. This work presents a 1:1 scale prototype of an 8 m 3 (2.1 × 2.1 × 2.3 m) stabilized adobe evaporative cooler, with a design based on the appropriate technology framework, and it was built as a chamber using double adobe walls, filled with wet sand, to induce evaporative cooling. Furthermore, the paper presents the prototype’s performance evaluation. The tests were carried out in the dry and wet states, with different volumes of water. The results show good performance compared with other prototypes, although the optimum watering volume could not be determined because of the high climate variance (outside temperature and humidity) that prevented the repetition of the experiments in identical operating conditions. Stabilized adobe proved to be a good choice for use in the cooler, even when subject to moisture accumulation, indicating an estimated long lifetime for the cooler. The data obtained about the efficiency of evaporative cooling show that the cooler, as expected, has its best performance on the hottest and driest days, reducing the internal temperature (up to 13.24 °C) and managing to keep the internal humidity. The cost, efficiency, durability, and replicability make the proposed evaporative cooler a feasible solution for food preservation.

42 ENGINEERING↗

The SAGA Survey. IV. The Star Formation Properties of 101 Satellite Systems around Milky Way–mass Galaxies

We present the star-forming properties of 378 satellite galaxies around 101 Milky Way analogs in the Satellites Around Galactic Analogs (SAGA) Survey, focusing on the environmental processes that suppress or quench star formation. In the SAGA stellar mass range of 10 6−10 M ⊙ , we present quenched fractions, star-forming rates, gas-phase metallicities, and gas content. The fraction of SAGA satellites that are quenched increases with decreasing stellar mass and shows significant system-to-system scatter. SAGA satellite quenched fractions are highest in the central 100 kpc of their hosts and decline out to the virial radius. Splitting by specific star formation rate (sSFR), the least star-forming satellite quartile follows the radial trend of the quenched population. The median sSFR of star-forming satellites increases with decreasing stellar mass and is roughly constant with projected radius. Star-forming SAGA satellites are consistent with the star formation rate–stellar mass relationship determined in the Local Volume, while the median gas-phase metallicity is higher and median H i gas mass is lower at all stellar masses. We investigate the dependence of the satellite quenched fraction on host properties. Quenched fractions are higher in systems with larger host halo mass, but this trend is only seen in the inner 100 kpc; we do not see significant trends with host color or star formation rate. Our results suggest that lower-mass satellites and satellites inside 100 kpc are more efficiently quenched in a Milky Way–like environment, with these processes acting sufficiently slowly to preserve a population of star-forming satellites at all stellar masses and projected radii.

79 ASTRONOMY AND ASTROPHYSICS↗

Elastomer Swell Behavior in 1-Propanol, Diisobutylene, Cyclopentanone, and a Furan Mixture Blended in E10 and a Blendstock for Oxygenate Blending (BOB)

The compatibility of four potential bio-derived blendstock molecules with infrastructure elastomers was determined by measuring the volume change following exposure. The blendstock molecules included 1-propanol, diisobutylene, cyclopentanone, and a furan mixture. The elastomers included two fluorocarbons, six nitrile rubbers (NBRs), and one each of fluorosilicone, neoprene, polyurethane, and silicone. The elastomers were exposed to the fuel molecules as blends ranging from 0 to 30 vol.% in both a blendstock for oxygenate blending (BOB) formulation and an E10 fuel. Silicone exhibited excessive swelling in each test fuel, while the other elastomers showed good compatibility (low swell) with diisobutylene, 1-propanol, and the furan mixture when BOB was used as the base fuel. The E10 base fuel produced high (>30%) swell in neoprene, polyurethane, and some nitrile rubbers. In most cases diisobutylene produced the least amount of volume expansion. In contrast, the addition of cyclopentanone produced unacceptably high swelling in each elastomer and is not considered suitable for use with these fuels. Analysis of the results showed that the swelling behavior is predominantly due to the polarity of the elastomer and test fuels.

03 NATURAL GAS↗