Electron Dynamics Within a MITL Containing a Load

In this paper, we derive the vacuum electric fields within specific cylindrically symmetric magnetically insulated transmission lines (MITLs) in the limit of an infinite speed of light for an arbitrary time-dependent current. We focus our attention on two types of MITLs: the radial MITL and a spherically curved MITL. We then simulate the motion of charged particles, such as electrons, present in these MITLs due to the vacuum fields. In general, the motion of charged particles due to the vacuum fields is highly nonlinear since the fields are nonlinear functions of spatial coordinates and depend on an arbitrary time-dependent current drive. Using guiding center theory, however, one can describe the gross particle kinetics using a combination of $\textbf {E} \times \textbf {B}$ and $\nabla B$ drifts. In addition, we compare our approximate inner MITL field models and particle kinetics with those from a fully electromagnetic simulation code. We find that the agreement between the approximate model and the electromagnetic simulations is excellent.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutral gas pressure dependence of ion–ion mutual neutralization rate constants using Landau–Zener theory coupled with trajectory simulations

In this computational study, we describe a self-consistent trajectory simulation approach to capture the effect of neutral gas pressure on ion–ion mutual neutralization (MN) reactions. The electron transfer probability estimated using Landau–Zener (LZ) transition state theory is incorporated into classical trajectory simulations to elicit predictions of MN cross sections in vacuum and rate constants at finite neutral gas pressures. Electronic structure calculations with multireference configuration interaction and large correlation consistent basis sets are used to derive inputs to the LZ theory. The key advance of our trajectory simulation approach is the inclusion of the effect of ion-neutral interactions on MN using a Langevin representation of the effect of background gas on ion transport. For H + – H – and Li + – H(D) – , our approach quantitatively agrees with measured speed-dependent cross sections for up to ~10 5 m/s. For the ion pair Ne + – Cl – , our predictions of the MN rate constant at ~1 Torr are a factor of ~2 to 3 higher than the experimentally measured value. Similarly, for Xe + – F – in the pressure range of ~20 000–80 000 Pa, our predictions of the MN rate constant are ~20% lower but are in excellent qualitative agreement with experimental data. Here, the paradigm of using trajectory simulations to self-consistently capture the effect of gas pressure on MN reactions advanced here provides avenues for the inclusion of additional nonclassical effects in future work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Formation of blade and slot die coated small molecule multilayers for OLED applications studied theoretically and by XPS depth profiling

Slot die coaters especially designed for low material consumption and doctor blades were used to process small molecule solutions for organic light-emitting diodes (OLEDs). Optimum process parameters were developed for the large-scale coating techniques to generate stable single and multiple layers only a few nanometers thick. Achieving a multilayer architecture for solution-processed OLEDs is the most challenging step. X-ray photoelectron spectroscopy sputter depth profiling was performed to determine defined interfaces between coated organic layers. Commercially available small molecules NPB (N,N’-Di(1-naphthyl)-N,N’-diphenyl-(1,1’-biphenyl)-4,4’-diamine) and BAlq (Bis(8-hdroxy-2methylquinoline)-(4-phenylphenoxy)aluminum), originally developed for vacuum deposition, were used as hole, respectively electron transport material. Defined double-layers were processed with both scalable coating methods using the orthogonal solvent approach. The use of non-orthogonal solvents resulted in complete intermixing of the material. The results are explained by calculations of solubilities and simulating drying and diffusion kinetics of the small molecule solutions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Use of a Mylar filter to eliminate vacuum ultraviolet pulse pileup in low-energy x-ray measurements

We describe a method to reduce vacuum ultraviolet (VUV) pulse pileup (PPU) in x-ray pulse-height Silicon Drift Detector (SDD) signals. An Amptek FAST SDD, with C1 (Si 3 N 4 ) window, measures bremsstrahlung emitted from PFRC-2 plasma to extract the electron temperature (T e ) and density (n e ). The C1 window has low transmissivity for photons with energy below 200 eV though will transmit some VUV and soft x-ray photons, which PFRC-2 plasmas abundantly emit. Multi-VUV-photon PPU contaminates the interpretation of x rays with energy > 100 eV, particularly in a low-energy exponential tail. The predicted low transmissivity of ~1 μm thick Mylar [polyethylene terephthalate (PET)] to photons of energy <100 eV led to the selection of Mylar as the candidate filter to reduce VUV PPU. Experiments were conducted on an x-ray tube with a graphite target and on a quasi-Maxwellian tenuous plasma (n e ~ 10 9 cm –3 ) with effective temperatures reaching 1500 eV. A Mylar filter thickness of 850 nm is consistent with the results. The Mylar-filter-equipped SDD was then used on the PFRC-2 plasma, showing a substantial reduction in the low-energy x-ray signal, supporting our hypothesis of the importance of VUV PPU. Here, we describe the modeling and experiments performed to characterize the effect of the Mylar filter on SDD measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of polarization on the structure of electromagnetic field and spatiotemporal distribution of e{sup +}e{sup –} pairs generated by colliding laser pulses

We have studied the production of electron–positron pairs due to polarization of vacuum in the presence of the strong electromagnetic field of two counterpropagating laser pulses. The structure of the electromagnetic field with the circular polarization has been determined using the 3D model of focused laser pulses, which was proposed by Narozhny and Fofanov. Analytic calculations have shown that the electric and magnetic fields are almost parallel to each other in the focal region when the laser pulses are completely transverse in the electric (E-wave) or magnetic (H-wave) field. On the other hand, the electric and magnetic fields are almost orthogonal when laser pulses consist of a mixture of E- and H-waves of the same amplitude. It has been found that although the latter configuration of colliding laser pulses has a much higher pair production threshold, it can generate much shorter electron–positron pulses as compared to the former configuration. The dependence of the production efficiency of pairs and their spatiotemporal distribution on the polarization of laser pulses has been analyzed using the structure of the electromagnetic field in the focal plane.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Oxygen on a Cylindrical Tungsten Polycrystal

Using low-energy (0–25 eV) threshold electron spectroscopy and contact potential difference in vacuum not worse than 2 × 10{sup –8} Pa, oxygen films obtained at 295, 325–1425 (in steps of 50), and 1575 K, including in subsequent heating from the adsorption temperature to 1925 ± 50 K, on​​the cylindrical surface of a gas-phase tungsten coating 30 μm thick on NbC-1 alloy (Nb – 1% Zr), used as a collector material for thermal emission in space-borne nuclear power plants, have been studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Soft matter and nanomaterials characterization by cryogenic transmission electron microscopy

Soft matter has historically been an unlikely candidate for investigation by electron microscopy techniques due to damage by the electron beam as well as inherent instability under a high vacuum environment. Characterization of soft matter has often relied on ensemble-scattering techniques. The recent development of cryogenic transmission electron microscopy (cryo-TEM) provides the soft matter community with an exciting opportunity to probe the structure of soft materials in real space. Cryo-TEM reduces beam damage and allows for characterization in a native, frozen-hydrated state, providing direct visual representation of soft structure. This article reviews cryo-TEM in soft materials characterization and illustrates how it has provided unique insights not possible by traditional ensemble techniques. Soft matter systems that have benefited from the use of cryo-TEM include biological-based “soft” nanoparticles (e.g., viruses and conjugates), synthetic polymers, supramolecular materials as well as the organic–inorganic interface of colloidal nanoparticles. We conclude that while many challenges remain, such as combining structural and chemical analyses; the opportunity for soft matter research to leverage newly developed cryo-TEM techniques continues to excite.

36 MATERIALS SCIENCE↗

Design of a proton-electron beam overlap monitor for the new RHIC electron lens, based on detecting energetic backscattered electrons

The optimal performance of the two electron lenses that are being implemented for high intensity polarized proton operation of RHIC requires excellent collinearity of the {approx}0.3 mm RMS wide electron beams with the proton bunch trajectories over the {approx}2m interaction lengths. The main beam overlap diagnostic tool will make use of electrons backscattered in close encounters with the relativistic protons. These electrons will spiral along the electron guiding magnetic field and will be detected in a plastic scintillator located close to the electron gun. A fraction of these electrons will have energies high enough to emerge from the vacuum chamber through a thin window thus simplifying the design and operation of the detector. The intensity of the detected electrons provides a measure of the overlap between the e- and the opposing proton beams. Joint electron arrival time and energy discrimination may be used additionally to gain some longitudinal position information with a single detector per lens.

43 PARTICLE ACCELERATORS↗

An Assessment of Molten Metal Detachment Hazards During Electron Beam Welding in Space

The safety issue has been raised with regards to potential molten metal detachments from the weld pool and cold filler wire during electron beam welding in space. This investigation was undertaken to evaluate if molten metal could detach and come in contact with astronauts and burn through the fabric of the astronauts' Extravehicular Mobility Unit (EMU) during electron beam welding in space. Molten metal detachments from either the weld/cut substrate or weld wire could present harm to a astronaut if the detachment was to burn through the fabric of the EMU. Theoretical models were developed to predict the possibility and size of the molten metal detachment hazards during the electron beam welding exercises at Low Earth Orbit (LEO). The primary molten metal detachment concerns were those cases of molten metal separation from the metal surface due to metal cutting, weld pool splashing, entrainment and release of molten metal due to filler wire snap-out from the weld puddle, and molten metal accumulation and release from the end of the weld wire. Some possible ways of obtaining molten metal drop detachments would include an impulse force, or bump, to the weld sample, cut surface, or filler wire. Theoretical models were developed for these detachment concerns from principles of impact and kinetic energies, surface tension, drop geometry, surface energies, and particle dynamics. The surface tension represents the force opposing the liquid metal drop from detaching whereas the weight of the liquid metal droplet represents a force that is tending to detach the molten metal drop. Theoretical calculations have indicated that only a small amount of energy is required to detach a liquid metal drop; however, much of the energy of an impact is absorbed in the sample or weld plate before it reaches the metal drop on the cut edge or surface. The tendency for detachment is directly proportional to the weld pool radius and metal density and inversely proportional to the surface tension of the liquid metal. For a detachment the initial kinetic energy of the weld pool with respect to the plate has to exceed the energy to form the extra surface required for the detachment of the pool. The difficulty is in transferring the energy from the point of impact through the plate and sample to the cut edge. It is likely that not all of the kinetic energy is available for detaching the pool; some may be sequestered in weld pool oscillations. The coefficient of restitution for the collision will be lower than one if irreversible deformation, for example plastic flow deformation, takes place during the collision. Thus determining the amount of energy from an impact that actually reaches the molten metal droplet is critical. Various molten metal detachment scenarios were tested experimentally in an enclosed vacuum chamber using the Ukrainian Universal Hand Tool, an electron beam welder designed for space welding. The experimental testing was performed in a 4 ft. X 4 ft. vacuum chamber at Marshall Space Flight Center, evacuated to vacuum levels of at least 50 microTorr, and also some welding garment material was utilized to observe the effect of the molten metal detachments on the material. A "carillon" apparatus consisting of four pendulum hammer strikers, each weighing approximately 3.65 lbs, raised to predetermined specific heights was used to apply an impact force to the weld sample/plate during electron beam welding and cutting exercises. The strikers were released by switching on an electric motor to rotate a pin holding wires retaining the strikers at desired heights. The specimens were suspended so as to be free to respond to the blows with a sudden velocity increment. The specimens were mounted on a hinged plate for minimizing effective mass with the option to fasten it down so as to raise its effective mass closer to that anticipated for an actual space welding scenario. Measurements were made of the impact energy and the horizontal fling distances of the detached metal drops. It was not particularly easy to generate the detachments for this experiment. This document presents the details of the theoretical modeling effort and a summary of the experimental effort to measure molten metal drop detachments from terrestrial electron beam welding in the enclosed vacuum chamber. The results of the experimental effort have shown that molten metal detachments can occur from the sample/weld plate only if a sufficiently large impact force is applied to the weld plate. A "weld pool detachment parameter" was determined to indicate whether detachment would occur. Detachment can be either full or partial (dripping), Partial detachment means that the weld pool detached from one side of the liquid-solid boundary so as to leave a hole at the puddle site but remained attached over part of the liquid-solid boundary and dripped down the plate with no fully detached material detected. Full detachment, however, does not necessarily mean that the whole pool fully detached; in some cases only a smaller portion of the pool detached, the remainder dripping down the plate. The weld pool detachment parameter according to theory and according to the empirical data allows a determination of whether full detachments might occur. Theoretical calculations indicated titanium alloy would be the most difficult from which to detach molten metal droplets followed by stainless steel and then by aluminum. The experimental results were for the most part consistent with the theoretical analysis and predictions. The above theory is applicable to other situations as desired for assessing the potential for molten metal detachments.

Fragomeni, James M.↗

Hydrogen Maser Clock (HMC) Experiment

The Hydrogen Maser Clock (HMC) project was originally conceived to fly on a reflight of the European Space Agency (ESA) free flying platform, the European Recoverable Carrier (EURECA) that had been launched into space and recovered by NASA's Space Transportation System (STS). A Phase B study for operation of HMC as one of the twelve EURECA payload components was begun in July 1991, and completed a year later. Phase C/D of HMC began in August 1992 and continued into early 1995. At that time ESA decided not to refly EURECA, leaving HMC without access to space. Approximately 80% of the flight support electronics are presently operating the HMC's physics package in a vacuum tank at the Smithsonian Astrophysical Observatory, and are now considered to be well-tested flight electronics. The package will continue to be operated until the end of 1997 or until a flight opportunity becomes avaiable. Appendices: letters and trip report; proceedings of the symposium on frequency standards and metrology; milli-celsius-stability thermal control for an orbiting frequency standard.

Vessot, Robert F. C.↗

An innovative experimental setup for the measurement of sputtering yield induced by keV energy ions

An innovative experimental equipment allowing to study the sputtering induced by ion beam irradiation is presented. The sputtered particles are collected on a catcher which is analyzed in situ by Auger electron spectroscopy without breaking the ultra high vacuum (less than 10{sup −9} mbar), avoiding thus any problem linked to possible contamination. This method allows to measure the angular distribution of sputtering yield. It is now possible to study the sputtering of many elements such as carbon based materials. Preliminary results are presented in the case of highly oriented pyrolytic graphite and tungsten irradiated by an Ar{sup +} beam at 2.8 keV and 7 keV, respectively.

36 MATERIALS SCIENCE↗

Russian Physics Journal (Former Soviet Physics Journal) and its Contribution to the Development of High-Current Pulse Electronics and Electrophysics

This article assesses the impact that the journal has had on the research and development in high-current pulse electronics and electrophysics, gas electronics, physics of gas lasers, relativistic microwave electronics, plasma electronics, etc. All these fields of research involve achievements in three areas of science and technology, namely, the creation of high-power nanosecond pulse generators; fundamental studies of nanosecond high-current discharges in gases, which have led to the discovery of the phenomenon of multielectron initiation of discharges, and studies of pulsed vacuum discharges, which have resulted in the discovery of explosive electron emission. The author began his research activities in these areas in 1958 at Tomsk Polytechnic Institute and continued them at the Institute of High Current Electronics of the Siberian Branch of the USSR Academy of Sciences, which was opened in 1977. A number of articles published in the journal were devoted to priority issues such as the studies of nanosecond discharges in gases, in vacuum, and in water; the description of the properties of explosive electron emission; the invention of metal-dielectric cathodes with ferroelectrics, and the proposal of gas compression in devices based on electrically exploded cylindrical conductors.

42 ENGINEERING↗

Development and construction status of the Mu2e electromagnetic calorimeter mechanical structures

Abstract The Mu2e experiment at Fermilab will search for the CLFV neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the evidence of physics beyond the Standard Model. Mu2e comprises a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides electron identification, a fast trigger and aids track reconstruction. It is a state-of-the-art crystal calorimeter and employs 1340 pure CsI crystals readout by UV-extended SiPM and fast electronics. The design consists of two identical annular disks positioned at the relative distance of 70 cm downstream the target.The hostile Mu2e conditions (total ionizing dose of 12 krad and a neutron fluence of 5 × 10 10 n/cm 2 @ 1 MeVeq (Si)/y, 1 T magnetic field and vacuum level of 10 −4 Torr) posed tight constraints on the mechanical structures and materials choice. The support structure of the two crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. SiPMs and front-end electronics for each crystal are assembled in one mechanical unit inserted in a machined copper holder. The units are supported by a plate made of vacuum-compatible material. The plate integrates the cooling system made of a network of copper lines flowing a low temperature fluid and placed in thermal contact with the copper holders. The DAQ is hosted in aluminum crates positioned on the lateral surface of the disks. The crates also integrate the DAQ electronics cooling system. We review the constraints on the calorimeter structures design, the development of all the structural components, including the simulations that have determined the materials and technological choices and the specifications of the cooling station, components production and quality assurance tests, the procedures for detector assembly, transportation and installation in the experimental area.

Instruments & Instrumentation↗

Survival of bacterial isolates exposed to simulated Jovian trapped radiation belt electrons and solar wind protons

With missions to Jupiter, the spacecraft will be exposed for extended durations to solar wind radiation and the Jovian trapped radiation belt. This study is designed to determine the effect of these radiation environments on spacecraft bacterial isolates. The information can be used in the probability of contamination analysis for these missions. A bacterial subpopulation from Mariner Mars 1971 spacecraft (nine spore-forming and three non-spore-forming isolates) plus two comparative organisms, Staphylococcus epidermidis ATCC 17917 and a strain of Bacillus subtilis var. niger, were exposed to 2, 12, and 25 MeV electrons at different doses with simultaneous exposure to a vacuum of 1.3 x 10(-4) N m-2 at 20 and -20 degrees C. The radioresistance of the subpopulation was dependent on the isolate, dose and energy of electrons. Temperature affected the radioresistance of only the spore-forming isolates. Survival data indicated that spores were reduced approximately 1 log/1500 J kg-1 (10 J kg-1=1 krad), while non-spore-forming isolates (micrococci) were reduced 1.5-2 logs/1500 J kg-1 with the exception of an apparent radioresistant isolate whose resistance approached that of the spores. The subpopulation was found to be less resistant to lower energy than to higher energy electrons. The bacterial isolates were exposed to 3 keV protons under the same conditions as the electrons with a total fluence of 1.5 x 10(13) p cm-2 and a dose rate of 8.6 x 10(9) p cm-2 s-1. The results showed that only 20% of S. epidermidis and 45% of B. subtilis populations survived exposure to the 3 keV protons, while the mean survival of the spacecraft subpopulation was 45% with a range from 31.8% (non-spore-former) to 64.8% (non-spore-former). No significant difference existed between spore-forming and non-spore-forming isolates.

Electrons↗

Beam-driven dynamics of aluminium dopants in graphene

Abstract Substituting heteroatoms into graphene can tune its properties for applications ranging from catalysis to spintronics. The further recent discovery that covalent impurities in graphene can be manipulated at atomic precision using a focused electron beam may open avenues towards sub-nanometer device architectures. However, the preparation of clean samples with a high density of dopants is still very challenging. Here, we report vacancy-mediated substitution of aluminium into laser-cleaned graphene, and without removal from our ultra-high vacuum apparatus, study their dynamics under 60 keV electron irradiation using aberration-corrected scanning transmission electron microscopy and spectroscopy. Three- and four-coordinated Al sites are identified, showing excellent agreement with ab initio predictions including binding energies and electron energy loss spectrum simulations. We show that the direct exchange of carbon and aluminium atoms predicted earlier occurs under electron irradiation, although unexpectedly it is less probable than the same process for silicon. We also observe a previously unknown nitrogen–aluminium exchange that occurs at Al–N double-dopant sites at graphene divacancies created by our plasma treatment.

36 MATERIALS SCIENCE↗

Considerations of metal joining processes for space fabrication, construction and repair

A comprehensive evaluation is conducted of candidate processes for metalworking in orbital (vacuum-microgravity) conditions. Attention is given to electron-beam welding, brazing, gas-tungsten arc welding, laser welding, plasma arc welding, and gas-metal arc welding. It is established that several of these processes will be required to cover all foreseeable requirements. Microgravity effects are considered minor, and efforts are being concentrated on problems associated with vacuum conditions and with process-operator safety.

Russell, C.↗

Low-temperature formation of epitaxial graphene on 6H-SiC induced by continuous electron beam irradiation

It is observed that epitaxial graphene forms on the surface of a 6H-SiC substrate by irradiating electron beam directly on the sample surface in high vacuum at relatively low temperature ({approx}670 Degree-Sign C). The symmetric shape and full width at half maximum of 2D peak in the Raman spectra indicate that the formed epitaxial graphene is turbostratic. The gradual change of the Raman spectra with electron beam irradiation time increasing suggests that randomly distributed small grains of epitaxial graphene form first and grow laterally to cover the entire irradiated area. The sheet resistance of epitaxial graphene film is measured to be {approx}6.7 k{Omega}/sq.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of photoemission and secondary emission from laboratory dust grains

The overall goal of this project is experimentally determine the emission properties of dust grains in order to provide theorists and modelers with an accurate data base to use in codes that predict the charging of grains in various plasma environments encountered in the magnetospheres of the planets. In general these modelers use values which have been measured on planar, bulk samples of the materials in question. The large enhancements expected due to the small size of grains can have a dramatic impact upon the predictions and the ultimate utility of these predictions. The first experimental measurement of energy resolved profiles of the secondary electron emission coefficient, 6, of sub-micron diameter particles has been accomplished. Bismuth particles in the size range of .022 to .165 micrometers were generated in a moderate pressure vacuum oven (average size is a function of oven temperature and pressure) and introduced into a high vacuum chamber where they interacted with a high energy electron beam (0.4 to 20 keV). Large enhancements in emission were observed with a peak value, delta(sub max) = 4. 5 measured for the ensemble of particles with a mean size of .022 micrometers. This is in contrast to the published value, delta(sub max) = 1.2, for bulk bismuth. The observed profiles are in general agreement with recent theoretical predictions made by Chow et al. at UCSD.

Hazelton, Robert C.↗