Climatology of Aerosol Optical Depth at Mid-Continental US Site: Ground-based Observations

The total aerosol burden in the atmosphere is typically represented by aerosol optical depth (AOD). To capture important and climate-relevant signatures of the aerosol burden, such as year-to-year and seasonal variability, continuous multi-year AOD observations are required. For more than two decades, these observations have been performed at the mid-continental Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Central Facility (CF) using ground-based passive remote sensing. The partially overlapping and fragmentary AOD records at the ARM SGP CF have been provided by four individual instruments, namely two co-located (C1 and E13) Multifilter Rotating Shadowband Radiometers (MFRSRs), a Normal Incidence Multifilter Radiometer (NIMFR), and a Cimel Sunphotometer (CSPHOT). Since these individual records are sporadic with instrument- and time-dependent data quality, development of a continuous multi-year high-quality AOD dataset is a challenging task. In this work, an initial development of a continuous 20-year (1997-2017) high-quality AOD product is introduced. The development involves (1) incorporation of the available data quality information and delivery of the historical time series of AOD with high quality from four individual instruments, (2) comparison of multiple AOD retrievals to identify potential instrument-related issues and/or retrieval problems, and (3) merging these individual time series, generation of a two-decade continuous climatology of high-quality AOD and reporting of the uncertainty estimations of the merged product.

Ground based remote sensing, Atmospheric Radiation↗

Direct measurement of absorbed dose to water in HDR {sup 192}Ir brachytherapy: Water calorimetry, ionization chamber, Gafchromic film, and TG-43

Purpose: Gafchromic film and ionometric calibration procedures for HDR {sup 192}Ir brachytherapy sources in terms of dose rate to water are presented and the experimental results are compared to the TG-43 protocol as well as with the absolute dose measurement results from a water calorimetry-based primary standard. Methods: EBT-1 Gafchromic films, an A1SL Exradin miniature Shonka thimble type chamber, and an SI HDR 1000 Plus well-type chamber (Standard Imaging, Inc., Middleton, WI) with an ADCL traceable S{sub k} calibration coefficient (following the AAPM TG-43 protocol) were used. The Farmer chamber and Gafchromic film measurements were performed directly in water. All results were compared to direct and absolute absorbed dose to water measurements from a 4 deg. C stagnant water calorimeter. Results: Based on water calorimetry, the authors measured the dose rate to water to be 361{+-}7 {mu}Gy/(h U) at a 55 mm source-to-detector separation. The dose rate normalized to air-kerma strength for all the techniques agree with the water calorimetry results to within 0.83%. The overall 1-sigma uncertainty on water calorimetry, ionization chamber, Gafchromic film, and TG-43 dose rate measurement amounts to 1.90%, 1.44%, 1.78%, and 2.50%, respectively. Conclusions: This work allows us to build a more realistic uncertainty estimate for absorbed dose to water determination using the TG-43 protocol. Furthermore, it provides the framework necessary for a shift from indirect HDR {sup 192}Ir brachytherapy dosimetry to a more accurate, direct, and absolute measurement of absorbed dose to water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 11: Commissioning of a system for the measurement of electron stopping powers

Purpose: To develop the techniques required to experimentally determine electron stopping powers for application in primary standards and dosimetry protocols. Method and Materials: A large-volume HPGe detector system (>80% efficiency) was commissioned for the measurement of high energy (5–35 MeV) electron beams. As a proof of principle the system was used with a Y-90/Sr-90 radioactive source. Thin plates of absorbing material (< 0.1 gcm-2) were then placed between the source and detector and the emerging electron spectrum was acquired. The full experimental geometry was modelled using the EGSnrc package to validate the detector design, optimize the experimental setup and compare measured and calculated spectra. Results: The biggest challenge using a beta source was to identify a robust spectral parameter to determine for each measurement. An end-point-fitting routine was used to determine the maximum energy, Emax, of the beta spectrum for each absorber thickness t. The parameter dEmax/dt is related to the electron stopping power and the same routine was applied to both measured and simulated spectra. Although the standard uncertainty in dEmax/dt was of the order of 5 %, by taking the ratio of measured and Monte Carlo values for dEmax/dt the uncertainty of the fitting routine was eliminated and the uncertainty was reduced to less than 2 %. The agreement between measurement and simulation was within this uncertainty estimate. Conclusion: The investigation confirmed the experimental approach and demonstrated that EGSnrc could accurately determine correction factors that will be required for the final measurement setup in a linac beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electroweak diboson production at ATLAS

This paper is giving an overview of recent ATLAS results on the production cross sections of gauge boson pairs decaying leptonically using data from pp collisions at √s = 13 TeV for ZZ and at √s = 8 TeV for W{sup ±} Z and W{sup ±} W{sup ±} at the LHC at CERN. The cross sections are found to be in agreement with the expectations from the Standard Model within the estimated uncertainties. The production cross section measurements also allow for studies of anomalous triple and quartic gauge couplings for which 95% confidence level limits are set.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bayesian Abel Inversion in Quantitative X-Ray Radiography

A common image formation process in high-energy X-ray radiography is to have a pulsed power source that emits X-rays through a scene, a scintillator that absorbs X-rays and uoresces in the visible spectrum in response to the absorbed photons, and a CCD camera that images the visible light emitted from the scintillator. The intensity image is related to areal density, and, for an object that is radially symmetric about a central axis, the Abel transform then gives the object's volumetric density. Two of the primary drawbacks to classical variational methods for Abel inversion are their sensitivity to the type and scale of regularization chosen and the lack of natural methods for quantifying the uncertainties associated with the reconstructions. In this work we cast the Abel inversion problem within a statistical framework in order to compute volumetric object densities from X-ray radiographs and to quantify uncertainties in the reconstruction. A hierarchical Bayesian model is developed with a likelihood based on a Gaussian noise model and with priors placed on the unknown density pro le, the data precision matrix, and two scale parameters. This allows the data to drive the localization of features in the reconstruction and results in a joint posterior distribution for the unknown density pro le, the prior parameters, and the spatial structure of the precision matrix. Results of the density reconstructions and pointwise uncertainty estimates are presented for both synthetic signals and real data from a U.S. Department of Energy X-ray imaging facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithm 1049: The Delaunay Density Diagnostic

Accurate approximation of a real-valued function depends on two aspects of the available data: the density of inputs within the domain of interest and the variation of the outputs over that domain. There are few methods for assessing whether the density of inputs is sufficient to identify the relevant variations in outputs—i.e., the “geometric scale” of the function—despite the fact that sampling density is closely tied to the success or failure of an approximation method. In this article, we introduce a general purpose, computational approach to detecting the geometric scale of real-valued functions over a fixed domain using a deterministic interpolation technique from computational geometry. The algorithm is intended to work on scalar data in moderate dimensions (2–10). Our algorithm is based on the observation that a sequence of piecewise linear interpolants will converge to a continuous function at a quadratic rate (in L 2 norm) if and only if the data are sampled densely enough to distinguish the feature from noise (assuming sufficiently regular sampling). We present numerical experiments demonstrating how our method can identify feature scale, estimate uncertainty in feature scale, and assess the sampling density for fixed (i.e., static) datasets of input–output pairs. Finally, we include analytical results in support of our numerical findings and have released lightweight code that can be adapted for use in a variety of data science settings.

97 MATHEMATICS AND COMPUTING↗

Developments in Sensitivity Methodologies and the Validation of Reactor Physics Calculations

The sensitivity methodologies have been a remarkable story when adopted in the reactor physics field. Sensitivity coefficients can be used for different objectives like uncertainty estimates, design optimization, determination of target accuracy requirements, adjustment of input parameters, and evaluations of the representativity of an experiment with respect to a reference design configuration. A review of the methods used is provided, and several examples illustrate the success of the methodology in reactor physics. A new application as the improvement of nuclear basic parameters using integral experiments is also described.

Palmiotti, Giuseppe↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

invspheroids6.f

Program invspheroid6.f inverts time domain measurements of normalized magnetic dipole polarizabilities in axial and transverse directions, for the parameters of a conducting magnetic (ferrous) spheroid: axial and transverse diameters, relative magnetic permeability and conductivity. It uses the sphere/spheroid approximation of J.T. Smith and H.F. Morrison, 2006, "Approximating spheroid inductive responses using spheres" (Geophysics, vol 71, G21-G25). It estimates uncertainty in the inverted parameters, based on a Monte Carlo method using multiple inversions with additional noise added to the data. The transmitter time function may be a step function pulse, a square wave pulse, or a half sine of given duration , at a given repetition rate. Any subset of spheroid parameters may be held fixes while solving for the others.

Smith, Torquil↗

QUiNN

SAND2023-05484O Quantification of Uncertainties in Neural Networks (QUiNN) is a python library centered around various probabilistic wrappers over PyTorch modules in order to provide uncertainty estimation in neural network (NN) predictions. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Sargsyan, Khachik↗

Space Situational Awareness for Python

SSAPy is a python package allowing for fast and precise orbital modeling. SSAPy is designed with speed and accuracy in mind and offers the following capabilities: - A variety of integrators, including Runge-Kutta, SciPy, SGP4, etc. - Customizable force propagation models, including a variety of Earth gravity models, lunar gravity, radiation pressure, etc. - Multiple-hypothesis tracking (MHT) UCT linker - Vectorized computations - Short arc probabilistic orbit determination - Conjunction probability estimation - Uncertainty quantification - Monte Carlo data fusion - Support for multiple coordinate frames (with coordinate frame conversions)

Schlafly, Edward↗

scANN

SAND2025-00656O scANN, also known as sampling by coinflips artificial neural networks, is a software tool that estimates uncertainty in artificial intelligence by performing Monte Carlo analysis on the weight matrices of feedforward neural networks. This computationally intensive process aims to explore the potential value added by future probabilistic hardware. The program’s output helps researchers gain insights into how probabilistic neural networks work. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

SciDAC↗

NIF Target Assembly Metrology Methodology and Results

During our inertial confinement fusion (ICF) experiments at the National Ignition Facility (NIF) we require cryogenic targets at the 1-cm scale to be fabricated, assembled, and metrologized to micron-level tolerances. During assembly of these ICF targets, there are physical dimensmetrology is completed using optical coordinate measurement machines that provide repeatable measurements with micron precision, while also allowing in-process data collection for absolute accuracy in assembly. To date, 51 targets have been assembled and metrologized, and 34 targets have been successfully fielded on NIF relying on these metrology data. In the near future, ignition experiments on NIF will require tighter tolerances and more demanding target assembly and metrology capability. Metrology methods, calculations, and uncertainty estimates will be discussed. Target diagnostic port alignment, target position, and capsule location results will be reviewed for the 2009 Energetics Campaign. The information is presented via control charts showing the effect of process improvements that were made during target production. Certain parameters, including capsule position, met the 2009 campaign specifications but will have much tighter requirements in the future. Finally, in order to meet these new requirements assembly process changes and metrology capability upgrades will be necessary.

42 ENGINEERING↗

Gaussian Process Optimization of Sensitivity-Based Similarity Metrics between New Nuclear Applications and New/Existing Benchmarks

Confidently designing safe, new nuclear criticality experiments requires expert judgement, which could take years of experience. Sensitivity/uncertainty (S/U) analysis can be utilized by less experienced individuals to conservatively estimate uncertainties in important parameters, such as k eff , in newly proposed nuclear applications. This type of analysis relies on matching new nuclear applications with existing benchmark experiments. The Whisper-1.1 software package included in MCNP6.2 ®1 contains more than 1,100 International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmarks. These benchmarks however rarely match new nuclear applications. The number of benchmarks available to match a given set of materials or geometric configurations varies significantly. Furthermore, recently performed benchmark experiments may not have had enough time to be properly documented and published. Benchmarks are vital for determining the accuracy of nuclear data and can assist nuclear physics and evaluators in improving nuclear data libraries. Exhaustively exploring the parameter space using simulations with software such as MCNP is too computationally expensive. In this work, Gaussian process optimization was implemented to reduce the number of simulations needed for optimization over multiple parameters. This optimization scheme was designed to selectively generate new benchmarks with high sensitivity-based similarity metrics to user-defined nuclear applications. Two benchmark models of spherically nested shells containing plutonium, uranium, tantalum, and water were used in the optimization to match an application containing plutonium plates, stacked in a tantalum reflector, surrounded by water.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Operation and investigation of a tilted bottom cavity for pyrgeometer characterizations

A new cavity for pyrgeometer characterizations has been built at the Infrared Radiometry Section of the World Radiation Center (WRC-IRS) at PMOD/WRC. The calculated effective emissivity of 0.99993{+-}0.00033 was obtained from Monte Carlo simulations taking into account the geometry and the measured temperature distributions of the cavity. The cavity is operated in a temperature range of -30 deg. C to +30 deg. C and is initially flushed with nitrogen to reduce the relative humidity in the cavity. The estimated uncertainties of retrieved pyrgeometer parameters k1, k2, and k3 are {+-}0.024, {+-}0.0008, and {+-}0.03, respectively. The relative uncertainty of pyrgeometer sensitivity C is 0.8%. The comparison with the cavity used since 1995 at PMOD/WRC gave average differences of 0.005, 0.00026, and 0.08 for k1, k2, and k3, respectively. The pyrgeometer sensitivity retrieved with the new cavity is on average 1.0% higher than with the original cavity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline vs. DER Scenario

Projections and associated uncertainty estimates are generated for a variety of user-selectable EV charging sessions, electricity tariffs, subsidy levels, revenue schemes, charging station configurations, and on-site solar and/or storage options. The outputs are presented in CHIP's web portal browser in the form of easily interpretable graphics (interactive graphs and bar charts) that facilitate convenient comparison among different scenarios to aid decision-making. The user should bring assumptions for modeling on simulation planning horizon, number of EV charging sessions per year, electricity costs (energy and demand charge rates; flat versus time-of-use rate), site capital costs (equipment for EV chargers and transformer), solar PV, and battery energy storage (kW).