Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

High-Resolution Ultrasound Imaging Using Model-Bases Iterative Reconstruction For Canister Degradation Detection

The inspection of the dry storage canisters that house spent nuclear fuel is an important issue facing the nuclear industry; currently, there are limited options available to provide for even minimal inspections. An issue of concern is stress corrosion cracking (SCC) in austenitic stainless steel canisters. SCC is difficult to predict and exhibits small crack opening displacements on the order of 15 30 m. Nondestructive examination (NDE) of such microscopic cracks is especially challenging, and it may be possible to miss SCC during inspections. The coarse grain microstructure at the heat affected zone reduces the achievable sensitivity of conventional ultrasound techniques. At Oak Ridge National Laboratory, a tomographic approach is under development to improve SCC detection using ultrasound guided waves and model-based iterative reconstruction (MBIR). Ultrasound-guided waves propagate parallel to the physical boundaries of the surface and allow for rapid inspection of a large area from a single probe location. MBIR is a novel, effective probabilistic imaging tool that offers higher precision and better image quality than current reconstruction techniques. This paper analyzes the canister environment, stainless steel microstructure, and SCC characteristics. The end goal is to demonstrate the feasibility of an NDE system based on ultrasonic guided waves and MBIR for canister degradation and to produce radar-like images of the canister surface with significantly improved image quality. The proposed methodology can potentially reduce human radiation exposure, result in lower operational costs, and provide a methodology that can be used to verify canister integrity in-situ during extended storage

Chatzidakis, Stylianos↗

WE-D-BRF-02: Acoustic Signal From the Bragg Peak for Range Verification in Proton Therapy

Purpose: Range verification in ion beam therapy relies to date on nuclear imaging techniques which require complex and costly detector systems. A different approach is the detection of thermoacoustic signals that are generated due to localized energy loss of ion beams. Aim of this work is to study the feasibility of determining the ion range with sub-mm accuracy by use of high frequency ultrasonic (US) transducers and to image the Bragg peak by tomography. Methods: A water phantom was irradiated by a pulsed 20 MeV proton beam with varying pulse intensity, length and repetition rate. The acoustic signal of single proton pulses was measured by different PZT-based US detectors (3.5 MHz and 10 MHz central frequencies). For tomography a 64 channel US detector array was used and moved along the ion track by a remotely controlled motor stage. Results: A clear signal of the Bragg peak was visible for an energy deposition as low as 10{sup 12} eV. The signal amplitude showed a linear increase with particle number per pulse and thus, dose. Range measurements were reproducible within +/− 20 micrometer and agreed well with Geant4 simulations. The tomographic reconstruction does not only allow to measure the ion range but also the beam spot size at the Bragg peak position. Conclusion: Range verification by acoustic means is a promising new technique for treatment modalities where the tumor can be localized by US imaging. Further improvement of sensitivity is required to account for higher attenuation of the US signal in tissue, as well as lower energy density in the Bragg peak in realistic treatment cases due to higher particle energy and larger spot sizes. Nevertheless, the acoustic range verification approach could offer the possibility of combining anatomical US imaging with Bragg Peak imaging in the near future. The work was funded by the DFG cluster of excellence Munich Centre for Advanced Photonics (MAP)

60 APPLIED LIFE SCIENCES↗

TH-C-17A-05: Cherenkov Excited Phosphorescence Oxygen (CEPhOx) Imaging During Multi-Beam Radiation Therapy

Purpose: Cherenkov radiation is created during external beam radiation therapy that can excite phosphorescence in tissue from oxygen-sensitive, bio-compatible probes. Utilizing the known spatial information of the treatment plan with directed multiple beam angles, Cherenkov Excited Phosphorescence Oxygen (CEPhOx) imaging was realized from the reconstructions of Cherenkov excited phosphorescence lifetime. Methods: Platinum(II)-G4 (PtG4) was used as the oxygen-sensitive phosphorescent probe and added to a oxygenated cylindrical liquid phantom with a oxygenated/deoxygenated cylindrical anomaly. Cherenkov excited phosphorescence was imaged using a time-gated ICCD camera temporallysynchronized to the LINAC pulse output. Lifetime reconstruction was carried out in NIRFAST software. Multiple angles of the incident radiation beam was combined with the location of the prescribed treatment volume (PTV) to improve the tomographic recovery as a function of location. The tissue partial pressure of oxygen (pO2) in the background and PTV was calculated based on the recovered lifetime distribution and Stern-Volmer equation. Additionally a simulation study was performed to examine the accuracy of this technique in the setting of a human brain tumor. Results: Region-based pO2 values in the oxygenated background and oxygenated/deoxygenated PTV were correctly recovered, with the deoxygenated anomaly (15.4 mmHg) easily distinguished from the oxygenated background (143 mmHg). The data acquisition time could be achieved within the normal irradiation time for a human fractionated plan. The simulations indicated that CEPhOx would be a sufficient to sample tumor pO2 sensing from tumors which are larger than 2cm in diameter or within 23mm depth from the surface. Conclusion: CEPhOx could be a novel imaging tool for pO2 assessment during external radiation beam therapy. It is minimally invasive and should work within the established treatment plan of radiation therapy with multiple beams in situations where tumor pO2 measurement is a pertinent radiotherapy efficiency and dosimetric need.

07 ISOTOPE AND RADIATION SOURCES↗

Inspection of a LOCA test rod at the Halden reactor project using gamma emission tomography

The LOCA test series IFA-650 conducted at the OECD Halden Reactor Project (HRP) has provided unique data on the performance of fuel rods during LOCA transients. One focus of the current investigations is the performance of the fuel in the ballooning stage of the LOCA transient. In this stage, relocation of fuel material is a possibility, in which case pellet fragments fall down to fill the void introduced by the increased volume of the ballooned cladding. This increases the heat load in that region, further promoting corrosion of the cladding. A special concern in the case of high-burnup fuels is the increasing number of small fuel fragments, which may be expected to cause a higher packing fraction in the ballooned region. In this work, a novel technique is presented for assessing the average density of the fuel material in the ballooned region of LOCA test rods. The investigation is based on non-destructive gamma emission tomography measurements, using the dedicated instrument recently developed at the HRP in collaboration with Westinghouse (Sweden) and Uppsala University. In this approach, the gamma radiation field surrounding the test rod has been measured with a narrowly collimated HPGe detector. Tomographic reconstruction of the data was performed, providing the radial gamma-ray source distribution within the measured volume, which reveals the fuel fragment distribution. From this, the density of the fuel in the measured volume (i.e., the packing fraction) may be calculated. The technique has been used to investigate a LOCA test rod of the Halden Reactor Project LOCA series. The LOCA experiment was carried out about one month prior to the gamma tomography examination. The results show that the distribution of the relocated fuel can be imaged using gamma rays from fission products. The reconstructions of the 662 keV rays from {sup 137}Cs and 1596 keV from {sup 140}Ba/La are demonstrated. In addition, the peaks of activation products offer valuable information on the location of the test rig structures, which may be utilized in a quantitative tomographic reconstruction to assess the spatially resolved packing fraction. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

WE-DE-BRA-05: Monte Carlo Simulation of a Novel Multi-Layer MV Imager

Purpose: To develop and validate a Monte Carlo (MC) model of a novel multi-layer imager (MLI) for megavolt (MV) energy beams. The MC model will enable performance optimization of the MLI design for clinical applications including patient setup verification, tumor tracking and MVCBCT. Methods: The MLI is composed of four layers of converter, scintillator and light detector, each layer similar to the current clinical AS1200 detector (Varian Medical Systems, Inc). The MLI model was constructed using the Geant4 Application for Tomographic Emission (GATE v7.1) and includes interactions for x-ray photons, charged particles and optical photons. Computational experiments were performed to assess Modulation Transfer Function (MTF), Detective Quantum Efficiency (DQE) and Noise Power Spectrum normalized by photon fluence and average detector signal (qNNPS). Results were compared with experimental measurements. The current work incorporates, in one model, the complete chain of events occurring in the imager; i.e. starting from x-ray interaction to charged particle transport and energy deposition to subsequent generation, interactions and detection of optical photons. Results: There is good agreement between measured and simulated MTF, qNNPS and DQE values. Normalized root mean squared error (NRMSE) between measured and simulated values over all four layers was 2.18%, 2.43% and 6.05% for MTF, qNNPS and DQE respectively. The relative difference between simulated and measured values for qNNPS(0) was 1.68% and 1.57% for DQE(0). Current results were obtained using a 6MV Varian Truebeam™ spectrum. Conclusion: A comprehensive Monte Carlo model of the MLI prototype was developed to allow optimization of detector components. The model was assessed in terms of imaging performance using standard metrics (i.e. MTF, qNNPS, DQE). Good agreement was found between simulated and measured values. The model will be used to assess alternative detector constructions to facilitate advanced clinical imaging applications including MV-CBCT and tumor tracking. The project was supported, partially, by a grant from Varian Medical Systems, Inc., and Award No. R01CA188446-01 from the National Cancer Institute. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Cancer Institute or the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

Fourier method for 3-dimensional data fusion of X-ray Computed Tomography and ultrasound

X-ray Computed Tomography (CT) is essential for nondestructive inspection of many manufactured components but is susceptible to various forms of artifacts and noise. In particular, multi-detector row cone-beam CT systems can suffer from so called “cone-beam” artifacts and partial volume effects, particularly on planar edges at the periphery of the field of view in the cone angle dimension. Uni-directional ultrasonic testing methods generally have extremely accurate in-plane depth resolution but poorer lateral resolution due to physical and geometric constraints. This paper presents a novel technique called Computed Tomographic Fusion (CT-F) which uses three-dimensional Fourier filtering to combine x-ray cone-beam CT reconstructions and ultrasound data in the frequency space. The result is a single image with improved accuracy and quality. CT-F mitigates artifacts while allowing for rapid, accurate characterization of large three-dimensional CT volumes. Finally, using simulations and experiments, we demonstrate artifact reduction and edge contrast improvement in volumetric reconstructions.

42 ENGINEERING↗

Development of a statistical model (tool) for classifying buried object detectability

To improve warfighter safety under changing requirements, assets must be adaptable and able to detect and mark buried hazards. Current GPR systems would benefit by improvements in speed, usability, and operational versatility to enhance operational effectiveness for all platforms and missions. Our sponsor requests that LLNL research GPR methodologies and approaches to allow for specific improvements to be made in those areas. MiRadar uses a novel multi-static array architecture coupled with tomographic processing to focus returned energy from the real (physical) and synthetic (motion-derived) apertures. 3D streaming movies of the subsurface are easily interpreted, slashing training times. Real-time processing codes enable imaging and operation three times faster; automated volumetric detection algorithms warn of possible hazards. In a two-week trial, multiple vehicle-mounted arrays and a new ultralightweight architecture on a small, unmanned aircraft system executed 498 runs, collecting over 400km of data on 13 preemplaced lanes containing 384 simulated buried threats.

42 ENGINEERING↗

Utah FORGE: Seismic DAS and Geophone Borehole Data Processing and 3D Imaging of Vp/Vs Ratio in the 2024 Stimulated Reservoir

This dataset includes a final report and a 3D velocity model derived from seismic DAS and geophone borehole data collected during the April 2024 stimulation of the reservoir at Utah FORGE. The report details the processing of over 50,000 P- and S-wave travel times used in a tomographic inversion to estimate the Vp/Vs ratio, revealing anomalies adjacent to wells 16A and 16B that may be associated with injected fracturing fluids. Additionally, Wadati analysis of more than 27,000 pairs of differential P- and S-wave travel times supports this interpretation with a high Vp/Vs estimate of 1.86, averaged over the dimensions of the earthquake cluster. The accompanying data file provides a 3D model of P- and S-wave velocities and Vp/Vs ratios, structured with spatial coordinates and velocity values.

15 GEOTHERMAL ENERGY↗

Imaging of colloidal deposits in granular porous media by X-ray difference micro-tomography

High resolution synchrotron-based X-ray computed microtomography (X-CMT) was used to identify the morphology of colloidal deposits formed in porous media. We show that difference microtomography - whereby a tomographic reconstruction is performed across an absorption edge - provides valuable information on the nature and location of the aggregates formed by the deposition of colloidal particles. Column experiments were performed using an idealized porous medium consisting of glass beads through which colloidal ZrO{sub 2} particles were transported. Tomographic reconstructions of the porous medium and of the aggregate structure provide an unique opportunity to observe colloidal particle deposits and of their morphology. These results show that the local pore geometry controls particle deposition and that deposits tend to form in a rather heterogeneous manner in the porous medium.

58 GEOSCIENCES↗

Technical Report on Subsurface Monitoring of the Brady Hot Spring Geothermal Site, Nevada, based upon Full Waveform Inversion

Abilities to accurately characterize the subsurface in a geothermal setting is key to assess and support production. An important element of geothermal reservoir monitoring is also the ability to investigate fluid transport within fracture network. This report focuses on improving subsurface imaging and monitoring in geothermal settings using full waveform inversion based on the adjoint method and time-lapse imaging. To assess our method, we rely on a dense seismic dataset collected in 2016 at the Brady Hot Springs geothermal site in Nevada for the DOE-funded project Poroelastic Tomography by Adjoint Inverse Modeling of Data from Seismology, Geodesy, and Hydrology. This dataset captures subsurface changes across four stages of geothermal power plant operations, which involve varying rates of fluid injection and extraction. Two velocity models were previously derived from this dataset using different methods: one based on travel times and another on sweep interferometry. Our first step is to refine these models using adjoint tomography, which has been applied successfully at global and regional-scales but is less common at the reservoir-scale. Two approaches are then explored for time-lapse analysis: directly comparing refined tomographic models from different stages or backpropagating waveform differences relative to a baseline tomographic model. The main take away is that both approaches highlight similar reservoir behaviors, but the latter approach is more computationally effective in capturing small-scale changes in subsurface properties. For this work, we leverage the use of Salvus (www.mondaic.com), an end-to-end seismic imaging solution, relying on the spectral element method to compute forward and adjoint simulations, and developed by Mondaic Ltd. It includes integrated workflow management that handles waveform and metadata, launches simulations, computes waveform misfits and adjoint sources, and iterates for model updates by nonlinear optimization.

15 GEOTHERMAL ENERGY↗

DLSIA: Deep Learning for Scientific Image Analysis

DLSIA (Deep Learning for Scientific Image Analysis) is a Python-based machine learning library that empowers scientists and researchers across diverse scientific domains with a range of customizable convolutional neural network (CNN) architectures for a wide variety of tasks in image analysis to be used in downstream data processing. DLSIA features easy-to-use architectures, such as autoencoders, tunable U-Nets and parameter-lean mixed-scale dense networks (MSDNets). Additionally, this article introduces sparse mixed-scale networks (SMSNets), generated using random graphs, sparse connections and dilated convolutions connecting different length scales. For verification, several DLSIA-instantiated networks and training scripts are employed in multiple applications, including inpainting for X-ray scattering data using U-Nets and MSDNets, segmenting 3D fibers in X-ray tomographic reconstructions of concrete using an ensemble of SMSNets, and leveraging autoencoder latent spaces for data compression and clustering. As experimental data continue to grow in scale and complexity, DLSIA provides accessible CNN construction and abstracts CNN complexities, allowing scientists to tailor their machine learning approaches, accelerate discoveries, foster interdisciplinary collaboration and advance research in scientific image analysis.

97 MATHEMATICS AND COMPUTING↗

Neutron tomographic analysis: Material characterization of silver and electrum coins from the 6th and 5th centuries BCE

Neutron tomography was applied to study a set of Greek silver coins and a single Lydian electrum coin minted in the 6 and 5th centuries BCE. The investigation was conducted at the new neutron imaging station DINGO at ANSTO in order to demonstrate capabilities and to explore limits of this non-invasive method in characterizing numismatic materials. From the reconstructed volume of each sample, the morphology, porosity, inclusions, and presence of composite structures can be revealed and evaluated. This information can be used to elucidate ancient minting technology and to prove authenticity. Moreover, the state of conservation, corrosion processes and attempts to repair the coins can be determined. - Highlights: •Pre-Roman coins •Non-destructive analysis •Neutron tomography: limit and capability.

36 MATERIALS SCIENCE↗

Quantitative characterization of high temperature oxidation using electron tomography and energy-dispersive X-ray spectroscopy

We report quantitative characterization of the high temperature oxidation process by using electron tomography and energy-dispersive X-ray spectroscopy. As a proof of principle, we performed 3D imaging of the oxidation layer of a model system (Mo 3 Si) at nanoscale resolution with elemental specificity and probed the oxidation kinetics as a function of the oxidation time and the elevated temperature. Our tomographic reconstructions provide detailed 3D structural information of the surface oxidation layer of the Mo 3 Si system, revealing the evolution of oxidation behavior of Mo 3 Si from early stage to mature stage. Based on the relative rate of oxidation of Mo 3 Si, the volatilization rate of MoO 3 and reactive molecular dynamics simulations, we propose a model to explain the mechanism of the formation of the porous silica structure during the oxidation process of Mo 3 Si. We expect that this 3D quantitative characterization method can be applied to other material systems to probe their structure-property relationships in different environments.

36 MATERIALS SCIENCE↗

GENFIRE: A generalized Fourier iterative reconstruction algorithm for high-resolution 3D imaging

Tomography has made a radical impact on diverse fields ranging from the study of 3D atomic arrangements in matter to the study of human health in medicine. Despite its very diverse applications, the core of tomography remains the same, that is, a mathematical method must be implemented to reconstruct the 3D structure of an object from a number of 2D projections. Here, we present the mathematical implementation of a tomographic algorithm, termed GENeralized Fourier Iterative REconstruction (GENFIRE), for high-resolution 3D reconstruction from a limited number of 2D projections. GENFIRE first assembles a 3D Fourier grid with oversampling and then iterates between real and reciprocal space to search for a global solution that is concurrently consistent with the measured data and general physical constraints. The algorithm requires minimal human intervention and also incorporates angular refinement to reduce the tilt angle error. We demonstrate that GENFIRE can produce superior results relative to several other popular tomographic reconstruction techniques through numerical simulations and by experimentally reconstructing the 3D structure of a porous material and a frozen-hydrated marine cyanobacterium. As a result, equipped with a graphical user interface, GENFIRE is freely available from our website and is expected to find broad applications across different disciplines.

36 MATERIALS SCIENCE↗

Objectives and Layout of a High-Resolution X-ray Imaging Crystal Spectrometer for the Large Helical Device (LHD)

A high-resolution X-ray imaging crystal spectrometer, whose concept was tested on NSTX and Alcator C-Mod, is being designed for LHD. This instrument will record spatially resolved spectra of helium-like Ar16+ and provide ion temperature profiles with spatial and temporal resolutions of < 2 cm and ≥ 10 ms. The stellarator equilibrium reconstruction codes, STELLOPT and PIES, will be used for the tomographic inversion of the spectral data. The spectrometer layout and instrumental features are largely determined by the magnetic field structure of LHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2-D soft x-ray arrays in the EAST

A high spatial and temporal resolution soft x-ray (SXR) imaging diagnostic has been installed in EAST for the study of magnetohydrodynamics activities and core high-Z impurity transport. Up to 122 lines of sight view the poloidal plasma from three directions (two up-down symmetrical horizontal arrays and one vertical array), which renders the diagnostic able to provide detailed tomographic reconstructions under various conditions. Fourier-Bessel method based on flux coordinates was employed for 2-D SXR tomographic reconstruction. Examples of several events measured by SXR diagnostic in EAST are shown, namely the crash patterns of sawtooth, periodical burst of edge localized modes, and the transport of high-Z intrinsic impurities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of heat release on strain rate field in turbulent premixed Bunsen flames

The effects of combustion on the strain rate field are investigated in turbulent premixed CH 4 /air Bunsen flames using simultaneous tomographic PIV and OH LIF measurements. Tomographic PIV provides three-dimensional velocity measurements, from which the complete strain rate tensor is determined. The OH LIF measurements are used to determine the position of the flame surface and the flame-normal orientation within the imaging plane. This combination of diagnostic techniques enables quantification of divergence as well as flame-normal and tangential strain rates, which are otherwise biased using only planar measurements. Measurements are compared in three lean-to-stoichiometric flames that have different amounts of heat release and Damköhler numbers greater than unity. The effects of heat release on the principal strain rates and their alignment relative to the local flame normal are analyzed. The extensive strain rate preferentially aligns with the flame normal in the reaction zone, which has been indicated by previous studies. The strength of this alignment increases with increasing heat release and, as a result, the flame-normal strain rate becomes highly extensive. These effects are associated with the gas expansion normal to the flame surface, which is largest for the stoichiometric flame. In the preheat zone, the compressive strain rate has a tendency to align with the flame normal. Away from the flame front, the flame – strain rate alignment is arbitrary in both the reactants and products. The flame-tangential strain rate is on average positive across the flame front, and therefore the turbulent strain rate field contributes to the enhancement of scalar gradients as in passive scalar turbulence. As a result, increases in heat release result in larger positive values of the divergence as well as flame-normal and tangential strain rates, the tangential strain rate has a weaker dependence on heat release than the flame-normal strain rate and the divergence.

47 OTHER INSTRUMENTATION↗

Toward Rapid Unattended X-ray Tomography of Large Planar Samples at 50-nm Resolution

X-ray tomography at sub-50 nm resolution of small areas ({approx}15 {mu}mx15 {mu}m) are routinely performed with both laboratory and synchrotron sources. Optics and detectors for laboratory systems have been optimized to approach the theoretical efficiency limit. Limited by the availability of relatively low-brightness laboratory X-ray sources, exposure times for 3-D data sets at 50 nm resolution are still many hours up to a full day. However, for bright synchrotron sources, the use of these optimized imaging systems results in extremely short exposure times, approaching live-camera speeds at the Advanced Photon Source at Argonne National Laboratory near Chicago in the US These speeds make it possible to acquire a full tomographic dataset at 50 nm resolution in less than a minute of true X-ray exposure time. However, limits in the control and positioning system lead to large overhead that results in typical exposure times of {approx}15 min currently.We present our work on the reduction and elimination of system overhead and toward complete automation of the data acquisition process. The enhancements underway are primarily to boost the scanning rate, sample positioning speed, and illumination homogeneity to performance levels necessary for unattended tomography of large areas (many mm{sup 2} in size). We present first results on this ongoing project.

77 NANOSCIENCE AND NANOTECHNOLOGY↗