Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Progress Towards Improved Analysis of TES X-ray Data Using Principal Component Analysis

The traditional method of applying a digital optimal filter to measure X-ray pulses from transition-edge sensor (TES) devices does not achieve the best energy resolution when the signals have a highly non-linear response to energy, or the noise is non-stationary during the pulse. We present an implementation of a method to analyze X-ray data from TESs, which is based upon principal component analysis (PCA). Our method separates the X-ray signal pulse into orthogonal components that have the largest variance. We typically recover pulse height, arrival time, differences in pulse shape, and the variation of pulse height with detector temperature. These components can then be combined to form a representation of pulse energy. An added value of this method is that by reporting information on more descriptive parameters (as opposed to a single number representing energy), we generate a much more complete picture of the pulse received. Here we report on progress in developing this technique for future implementation on X-ray telescopes. We used an 55Fe source to characterize Mo/Au TESs. On the same dataset, the PCA method recovers a spectral resolution that is better by a factor of two than achievable with digital optimal filters.

Low-temperature detectors A[center dot] Transition↗

Testing of A Photon-Counting Optical Ground Receiver With Emulated Space-to-Ground Link Effects

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) developed and previously characterized a photon-counting optical ground receiver system. The receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization High Photon Efficiency (HPE) Standard. The standard will be used on the Optical Artemis-2 Orion (O2O) communications demonstration and the Deep Space Optical Communication (DSOC) project aboard the Psyche spacecraft. The receiver system consists of a fiber interconnect, up to sixteen superconducting nanowire single-photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Previously, the receiver system architecture was described and test results without emulated link effects were presented. SNSPD device properties, which impact detection jitter and time delay, can limit the receiver dynamic range, especially when operating with varying flux rates (>10 dB) between detectors. Codeword error-rate curves with and without simulated clock drifts attributed to Doppler shift and space transmitter clock differences are presented. Results with ±66 ppm clock differences show minimal performance impact (<0.2 dB). Test results show that the receiver dynamic range (>28 dB) is limited by changing SNSPD detection delays at high photon flux rates.

optical communications↗

Testing of A Photon-Counting Optical Ground Receiver With Emulated Space-to-Ground Link Effects

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) developed and previously characterized a photon-counting optical ground receiver system. The receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization High Photon Efficiency (HPE) Standard. The standard will be used on the Optical Artemis-2 Orion (O2O) communications demonstration and the Deep Space Optical Communication (DSOC) project aboard the Psyche spacecraft. The receiver system consists of a fiber interconnect, up to sixteen superconducting nanowire single-photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Previously, the receiver system architecture was described and test results without emulated link effects were presented. SNSPD device properties, which impact detection jitter and time delay, can limit the receiver dynamic range, especially when operating with varying flux rates (>10 dB) between detectors. Codeword error-rate curves with and without simulated clock drifts attributed to Doppler shift and space transmitter clock differences are presented. Results with ±66 ppm clock differences show minimal performance impact (<0.2 dB). Test results show that the receiver dynamic range (>28 dB) is limited by changing SNSPD detection delays at high photon flux rates.

optical communications↗

Development of Concurrent Artificially-Intelligent Spectrometry and Adaptive Lidar System (CASALS) for Swath Mapping From Space

We present the design and performance of a Concurrent Artificially-intelligent Spectrometry and Adaptive Lidar System (CASALS) for 3D imaging from Space. With a single fast wavelength tuning laser, CASALS accomplishes a 1,200 resolvable spots swath mapping by grating dispersion wavelength steering. Any subset of these 1,200 spots can be selected by wavelength switching. The validation operating principle was accomplished and reported in IGASS-2022. With configurable base design, we report the designs and progress of the CASALS airplane campaign with 256 contiguous ground spots. It is accomplished with a single fast tuning lase at 1040-nm, 1.152MHz tuning rate, and pulse modulated 2-ns on each wavelength. Return pulses are mapped to an eight-pixel detector array with single-photon sensitivity. The lidar returns are time-multiplexed to two outputs that are digitized with two 1-GSPS-digitizer. A grating spectrometer rejects solar background noise spatially and spectrally. We are developing a 1040-nm CASALS intended for multiple LEO orbit missions: Earth Venture Mission on ESPA Grande, STV Mission on ESPA Grande SmallSat, STV Mission on spacecraft equivalent to ICESat power (SWaP,) and splitting the laser beam requires higher laser pulse energy.

ranging lidar↗

The elemental and isotopic composition of quiet time low energy cosmic rays

Isotopic abundances during several periods of solar quiet times are derived from multidimensional analysis of double dE/dX modes made with two 150 micron dE detectors and a 3000 micron stopping E detector. The spectra of the low-energy cosmic rays suggest that all the primary species of elements exhibit flux enhancements. The flux increases of 5-12 MeV/N for C, Mg, Si, and Fe are different from the anomalous components and may result from solar contamination of the quiet time data or from interplanetary acceleration processes. They may be anomalous components (ACR), although to a lesser extent than He, N, O, and Ne. The isotopic data indicate that the ACR component is predominantly N-14, O-16, and Ne-20. The isotopic compositions require that the ACRs have traversed a very limited amount of material, suggesting a local origin for them.

Smith, B.↗

Assessment of SNPP VIIRS RSB detector-to-detector differences using deep convective clouds and deserts

An accurate on-orbit characterization of the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership satellite is essential to satisfy the requirements from NOAA, NASA, and the general research community for high-quality operational and research products. NASA’s Land Science Investigator-led Processing System (LSIPS) sensor data records (SDRs) are utilized to assess the stability of the calibrated top of atmosphere reflectance over the deep convective clouds (DCCs) and over the Libya-4desert site. The results from DCCs and desert show detector-to-detector (D2D) reflectance differences in the VIIRS reflective solar bands, 10 moderate-resolution bands (M-bands, M1to M5, M7 to M11), and three imagery resolution bands (I-bands, I1-I3). More importantly, the D2D differences exhibit an increase in magnitude over time for bands M1 to M5 and I1to I2, which induces noticeable striping and higher uncertainties in the downstream data products. The largest D2D difference is observed in bands M1 and M2, with magnitudes greater than1.8% in trends among the 16 detectors and standard deviations less than 0.12% over time. TheD2D stability assessment results over DCCs are consistent with those observed over the Libya-4desert site. To improve the quality of the calibrated SDR reflectance data, NASA’s VIIRS characterization support team has improved the calibration algorithm to incorporate corrections based on these DCC measurements to mitigate the striping (detector differences) observed in the current version of the SDR. These improvements are planned to be included in the next mission reprocessing of the LSIPS land products.

SNPP VIIRS↗

Passive imaging through the turbulent atmosphere - Fundamental limits on the spatial frequency resolution of a rotational shearing interferometer

The signal-to-noise (S/N) ratio to be expected when a 180 deg rotationally shearing interferometer is used for image recovery at the diffraction limit of a large telescope is computed. The variance and covariance of the irradiance fluctuations at the detector array are shown to yield measures of the high-frequency spatial spectrum of the source. Four fundamental sources of noise are considered: temporal fluctuations of the source, space-time fluctuations of the atmosphere, shot noise in the detected photocurrents, and the effects of finite sampling. S/N is found to be directly proportional to the angular resolution of the telescope, the single-frame integration time, the square root of the number of frames, the cube of the operating wavelength, the quantum efficiency of the detector, and the average spectral irradiance from the source on the pupil. It is inversely proportional to the cube of the field angle subtended by the source (or part thereof) under study.

Burke, J. J.↗

Detection and Estimation of an Optical Image by Photon-Counting Techniques

Statistical description of a photoelectric detector is given. The photosensitive surface of the detector is divided into many small areas, and the moment generating function of the photo-counting statistic is derived for large time-bandwidth product. The detection of a specified optical image in the presence of the background light by using the hypothesis test is discussed. The ideal detector based on the likelihood ratio from a set of numbers of photoelectrons ejected from many small areas of the photosensitive surface is studied and compared with the threshold detector and a simple detector which is based on the likelihood ratio by counting the total number of photoelectrons from a finite area of the surface. The intensity of the image is assumed to be Gaussian distributed spatially against the uniformly distributed background light. The numerical approximation by the method of steepest descent is used, and the calculations of the reliabilities for the detectors are carried out by a digital computer.

Wang, Lily Lee↗

The Observed On-Orbit Background of the ACIS Instrument of the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic x-rays. The ACIS instrument contains eight Front-Illuminated (FI) CCDs and two Back-Illuminated (BI) CCDs. The FI and BI CCDs exhibit dramatically different responses to enhancements in the particle flux. The FI CCDs show relatively little increase in the overall count rate, typical increases are 1-3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The directions of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the detectors. The spectral distribution can be characterized by a simple power law. The events produce morphologies which are similar to cosmic x-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, Paul P.↗

Rocket observations of energetic particles at the geomagnetic equator

Energetic particle detectors were included in the payloads of two rockets launched in Peru during the Condor campaign of 1983. These night-time flights reached altitudes of 587 and 535 km, respectively. The pitch-angle distribution is anisotropic with the maximum at 90 deg. Each payload included two solid-state detectors differing in the thickness of the aluminum coating. Comparison of the fluxes measured by the two detectors leads to the conclusion that, on both occasions, the energetic particles are predominantly helium ions. The flux is small below 200 km, increases linearly to 350 km, and then more slowly to apogee. The east-west asymmetry of flux, noted at 200 km in a previous equatorial launch, is not seen at greater altitudes, consistent with the flux profile and the large gyroradius of the ions.

Smith, L. G.↗

Fabrication of a Hybrid Transition Edge Sensor Array for Lynx

Lynx is a proposed NASA X-Ray telescope flight mission aimed at achieving state-of-the-art angular and energy resolution with a 100 kilopixel array to probe the hot energetic young universe in unprecedented detail. To achieve these goals, our team plans on leveraging our current work in development of the focal plane for the Athena X-Ray Integral Field Unit (X-IFU) while advancing the state-of-the-art in transition edge sensor (TES) X-ray detector technology. The TES is an optimal technology for achieving both high energy and fine angular resolution at the same time because pixel features can be made extremely small and the absorber which dominates the heat capacity can be tuned to meet resolution requirements. Specifically, the proposed mission concept calls for a hybrid detector of three different arrays fabricated in the same planar process in one focal plane and optimized for different science goals. The main arrays consist of 5x5 hydras, 25 pixels of 4 micron thick Au absorbers each with a different thermal link to one common TES. The outer array has absorbers on a 50-micron pitch for most of the 5 arc-minute field-of-view, and the inner array has 25-micron absorbers for the central 1 arc-minute region. A high resolution array consisting of single pixel 1 micron thick Au absorbers on 50-micron pitch will lie off to the side. Reading out an array of this magnitude will likely require improvements in indium bump bonding to superconducting flexible wiring. Fabrication of absorbers of two different sizes requires electroplating through a photoresist mold by careful tuning of the current density to achieve uniform flat absorbers on a fine pitch scale, followed by ion milling to yield narrow streets separating the pixels while preserving high quantum efficiency. We report on progress made at fabricating the hybrid array with different absorber sizes and thicknesses. Further, we also report on ongoing work to adequately heat sink the pixels with backside wire bonding and copper coating. We also report on work to improve detector pixel yield and top side indium bump bonding to flexible wiring.

Focal plane array↗

HgCdTe e-APD Detector Arrays with Single Photon Sensitivity for Space Lidar Applications

A multi-element HgCdTe electron initiated avalanche photodiode (e-APD) array has been developed for space lidar applications. The detector array was fabricated with 4.3-μm cutoff HgCdTe which covered a spectral response from 0.4 to 4.3 μm. We have characterized a 4x4 detector array with 80 μm square elements and an integrated custom cryogenic silicon read-out integrated circuit (ROIC). The device operated at 77K inside a small closed-cycle Dewar. Measurements showed a unity gain quantum efficiency of about 90% at 1.55 μm. The bulk dark current of the HgCdTe e-APD at 77K was less than 50,000 input referred electrons/s at 12 V APD bias where the APD gain was 620 and the measured noise equivalent power (NEP) was 0.4 fW/Hz1/2. The electrical bandwidth of the ROIC was about 6 MHz, which was chosen to match the laser pulse width of our CO2 lidar. Even with the relatively low bandwidth, the high APD gain and low dark current enabled the device to detect single photon events. Because the APD was biased below the break-down voltage, the detector output was linear with the input optical signal and there was no dead-time and afterpulsing. A new series of HgCdTe e-APDs are being developed with a much wider bandwidth ROIC and higher gain HgCdTe e-APD array, which is expected to give a much better performance in linear mode photon counting applications.

HgCdTe↗

Observations of the ratio of low-energy cosmic-ray positrons and electrons during solar quiet times

Simultaneous observations of the quiet-time interplanetary positron and electron spectra between 0.16 and 1.6 MeV are reported. The measurements were made in selected time intervals between October 1, 1972 and February 1, 1973 with the Caltech Electron/Isotope Spectrometer on the IMP-7 satellite. The detector system consists of a stack of 11 silicon surface-barrier detectors surrounded by a plastic scintillator anti-coincidence cup. The method of e+ identification and possible background effects are discussed and upper limits to the 0.16 to 1.6 MeV quiet-time positron flux are reported. During this period positrons amounted to less than 20% of the total 0.16 to 1.6 MeV electron flux.

Hurford, G. J.↗

The absence of rapid X-ray variability in active galaxies

Variations on time scales ranging from minutes to several hours in the X-ray flux from 54 observations of 38 active galaxies are identified. The sample is composed mostly of Seyfert I galaxies but also includes radio galaxies, NELG's BL Lacs and 3C 273. Only NGC 6814 varied on time scales as short as 100 sec. No other source was observed to vary with a time scale of less than 12 hours. Large amplitude short term variations are not a characteristic of the X-ray emission from active galaxies. Upper limits on sigma sub I/I ranged from 2% for Cen A, 5% for NGC 4151, to approximately 20% for sources giving 1 ct/sec in the detector. Three objects NGC 3227, NGC 4151 and MCG 5-23-16 show variability consistent with a time scale of approximately 1 day. Ways to reconcile the rapid variability seen for NGC 6814 (and NGC 4051) with the general stability observed for the other objects are considered.

Tennant, A. F.↗

A Measurement of the Energy Spectra of Cosmic Rays from 20 to 1000 GeV Per Amu

The design features and operational performance from the test flight of the fourth generation of spherical geometry cosmic ray detectors developed at Bristol University (Bristol University Gas Scintillator 4 - BUGS-4) are presented. The flight from Ft. Sumner (NM) in Sept. 1993 was the premier flight of a large (1m radius) spherical drift chamber which also gave gas scintillation and Cerenkov signals. The combinations of this chamber with one gas and two solid Cerenkov radiators lead to a large aperture factor (4.5 m2sr), but low (approximately 3.5 g/sq cm) instrument mass over the energy sensitive range 1 to several hundred GeV/a. Moreover, one simple timing measurement determined the impact parameter which provided a trajectory (path length) correction for all detector elements. This innovative and efficient design will be of interest to experimental groups engaged in studies of energetic charged particles. Although there were technical problems on the flight, which were compounded by the total destruction of BUGS-4 by fire while landing in Oklahoma, there was a period of stable operation during which the instrument was exposed at float altitude (approximately 125,000 ft.) to high energy cosmic rays. We present the performance of the instrument as determined from the analysis of these data and an appraisal of its novel design features. Suggestions for design improvements in a future instrument are made.

Gregory, J. C.↗

Novel Multiplexing Technique for Detector and Mixer Arrays

Future submillimeter and far-infrared space telescopes will require large-format (many 1000's of elements) imaging detector arrays to perform state-of-the-art astronomical observations. A crucial issue related to a focal plane array is a readout scheme which is compatible with large numbers of cryogenically-cooled (typically < 1 K) detectors elements. When the number of elements becomes of the order of thousands, the physical layout for individual readout amplifiers becomes nearly impossible to realize for practical systems. Another important concern is the large number of wires leading to a 0.1-0.3 K platform. In the case of superconducting transition edge sensors (TES), a scheme for time-division multiplexing of SQUID read-out amplifiers has been recently demonstrated. In this scheme the number of SQUIDs is equal to the number (N) of the detectors, but only one SQUID is turned on at a time. The SQUIDs are connected in series in each column of the array, so the number of wires leading to the amplifiers can be reduced, but it is still of the order of N. Another approach uses a frequency domain multiplexing scheme of the bolometer array. The bolometers are biased with ac currents whose frequencies are individual for each element and are much higher than the bolometer bandwidth. The output signals are connected in series in a summing loop which is coupled to a single SQUID amplifier. The total number of channels depends on the ratio between the SQUID bandwidth and the bolometer bandwidth and can be at least 100 according to the authors. An important concern about this technique is a contribution of the out-of-band Johnson noise which multiplies by factor N(exp 1/2) for each frequency channel. We propose a novel solution for large format arrays based on the Hadamard transform coding technique which requires only one amplifier to read out the entire array of potentially many 1000's of elements and uses approximately 10 wires between the cold stage and room temperature electronics. This can significantly reduce the complexity of the readout circuits.

Karasik, Boris S.↗

The AXAF/XRS test dewar - A versatile design

The X-Ray Spectrometer (XRS) to be flown on the Advanced X-ray Astrophysics Facility (AXAF) consists of an array of microcalorimeters and an Adiabatic Demagnetization Refrigerator (ADR). The ADR provides an operating temperature of 0.065 to 0.100 K. To support extensive development testing of the ADR and the detector array, a test dewar has been designed and built that surpasses specification requirements. Pumping on the liquid helium bath with a 47 l/s pump, we have achieved temperatures lower than 1.5 K with a hold time in excess of 72 hrs. The dewar can be operated without liquid nitrogen with a hold time of 36 hrs. This feature was incorporated in the design because boiling nitrogen may introduce microphonic noise to the detectors. To further reduce the susceptibility to microphonic vibration a unique suspension system utilizing Kevlar fibers was devised which provides both translational and rotational rigidity to the detector mount. Finally, the dewar is very manageable and may be rotated by only one person.

Weintz, Karl F.↗

Research relative to high resolution camera on the advanced X-ray astrophysics facility

The HRC (High Resolution Camera) is a photon counting instrument to be flown on the Advanced X-Ray Astrophysics Facility (AXAF). It is a large field of view, high angular resolution, detector for the x-ray telescope. The HRC consists of a CsI coated microchannel plate (MCP) acting as a soft x-ray photocathode, followed by a second MCP for high electronic gain. The MCPs are readout by a crossed grid of resistively coupled wires to provide high spatial resolution along with timing and pulse height data. The instrument will be used in two modes, as a direct imaging detector with a limiting sensitivity of 10 to the -15 ergs sq cm sec in a 10 to the 5th second exposure, and as a readout for an objective transmission grating providing spectral resolution of several hundreds to thousands.

Source record↗