Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Multi-Line Gamma-Ray Spectrometer Performance of a Si(Li) Detector Stack

Experimental data is presented which for the first time displays multi-line spectrometer performance of a Si(Li) detector stack at elevated temperature. The stack consists of four elements, each with a 2 cm diameter active area. Ba-133 and Ag-110m spectra are obtained using various techniques to enhance the peak-to-background ratio. Spectral data are shown as a function of temperature (94 K less than or = T less than or = 230 K) using optimized peak shaping.

Hubbard, G. Scott↗

Measurement of the primary cosmic electron spectrum from 10 to about 250 GeV

The intensity and energy spectrum of primary cosmic electrons from 10 to about 250 GeV have been studied by using balloon-borne detectors. The detectors were large-area ionization calorimeters which sampled showering particles frequently and demonstrated an energy resolution of about 7% in calibration tests. On one of the flights a time-of-flight system and detectors to sample the lateral properties of showers were used to examine and to test background rejection. The results of the balloon flights from Alamogordo, N. Mex., in 1970 and Cape Girardeau, Mo., in 1972 indicated that the primary cosmic ray electron differential energy spectrum exhibits no change of slope in the energy range measured and is well represented by a power law. The results indicate that the cosmic electron spectrum is steeper than the cosmic ray proton spectrum. It is shown that these data are consistent with the leakage lifetime model for the propagation of cosmic electrons in the galaxy, although other more complex models cannot be excluded on the basis of these data.

Silverberg, R. F.↗

A directional low energy gamma-ray detector

The sensitivity of a directional gamma ray detector, which relies on blocking a source to determine its direction and energy spectrum, is calculated and compared to the more conventional well-shaped shielded detectors. It is shown that such an anticollimator detection system provides a basis for measuring the celestial diffuse gamma ray background, gamma ray sources and bursts with good energy, angular, and time resolution, and that additionally the system is 20 to 50 times as sensitive as conventional detectors when compared on a per unit mass basis.

Morfill, G.↗

A directional low energy gamma-ray detector

The sensitivity of a directional gamma ray detector, which relies on blocking a source to determine its direction and energy spectrum, is calculated and compared to the more conventional well shaped shielded detectors. It is shown that such an anticollimator detection system provides a basis for measuring the celestial diffuse gamma ray background, gamma ray sources and bursts with good energy, angular, and time resolution, and that additionally the system is 20 to 50 times as sensitive as conventional detectors when compared on a per unit mass basis.

Morfill, G.↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

Improving ICARUS Track Reconstruction Algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino (SBN) program at Fermilab. The main goal of the experiment is to investigate the possibility of sterile neutrinos in the O(1 eV) mass region and provide clarification of the anomaly detected from the Liquid Scintillator Neutrino Detector (LSND) and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber (LAr-TPC), that can provide excellent 3D imaging and calorimetric reconstruction of any ionizing particles. This detection technique allows a detailed study of neutrino interactions, spanning a wide energy spectrum (from a few keV to several hundreds of GeV). The detector consists of two identical adjacent modules, filled with a total of 760 tons of ultra-pure liquid argon. Each module houses two LAr-TPCs separated by a common cathode with a maximum drift distance of 1.5 m, equivalent to about 1 ms drift time for the nominal $500$ V/m electric drift field. The anode is made of three parallel wire planes positioned 3 mm apart, where the stainless-steel wires are oriented on each plane at a different angle with respect to the horizontal direction ($+60^\degree$,$-60^\degree$,$0^\degree$). The first two planes (Induction 1 and Induction 2) provide a non-destructive charge measurement, whereas the ionization charge is fully collected by the last collection plane. In total, 53248 wires with a 3 mm pitch and length up to 9 m are installed in the detector. In the first stage of the reconstruction, segments of waveforms corresponding to physical signals (hits) are searched for in the deconvolved wire waveform with a threshold-based hit-finding algorithm. Each hit is then fitted with a Gaussian, whose area is proportional to the number of drift electrons generating the signal. In the second stage of the reconstruction, hits are passed as input to Pandora, a framework software composed of different pattern recognition algorithms, that performs a 3D reconstruction of the full image recorded in the collected event, including the identification of interaction vertices and tracks and showers inside the TPC. These are organized into a hierarchical structure (called slice) of particles generated starting from a primary interaction vertex. In some cases, related to the inefficiencies in the hit detection or excessive deflection of the particle trajectory, Pandora breaks the particle's track into two or more smaller pieces and considers each piece as an independent track. We studied this phenomenon focusing on primary muons from ν_μ CC interactions contained in a single module with a track at least 20 cm long, to exclude delta rays. The study determined that about $7-8\%$ of the muon tracks are broken. Approximately $80\%$ of the times, Pandora assigns all segments of the track to the same slice (intra-slice track split), while in the remaining $20\%$ of the cases, one of the segments is associated with another slice (extra-slice track split). To mitigate this phenomenon, we designed an algorithm that detects and stitches the tracks broken by Pandora for the intra-slice split. In Monte Carlo simulations, the algorithm showed an efficiency exceeding $80\%$ and a purity exceeding $93\%$.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Super Photon Counters

The perfect photon detector would measure the arrival time, the energy, the polarization, and the position of every arriving quantum, but that is easier said than done. Two groups have now succeeded in doing time-resolved spectroscopy on the Crab Nebula pulsar, measuring everything but the polarization, with reports from Romani et al. at Stanford and from Perryman et al. at ESTEC. Both groups use superconducting detectors to gain the necessary speed and sensitivity. The photon can heat the electrons in a superconductor biased in the middle of its resistive transition, or break bound superconducting electron-hole pairs, which can then be collected. Three years ago, Peacock et al. reported that they had detected single optical photons with a superconducting tunnel junction (STJ), and Paresce wrote a News and Views article. A tunnel junction uses two pieces of conductive material, separated by a tiny gap of insulating material or even vacuum. If the gap is thin enough, electrons can tunnel across anyway, and if the conductors are superconductors, the junction displays very useful quantum mechanical properties and electrical nonlinearities. Amplifiers, detectors, oscillators, and computer circuits can all be made from them. Their special advantage is that they operate at very low temperatures, dissipate very little power, operate very fast, and are very small.

Mather, John↗

Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k

DarkSide-20k (DS-20k) is a dark matter detection experimentunder construction at the Laboratori Nazionali del Gran Sasso (LNGS)in Italy. It utilises ∼ 100 t of low radioactivity argon from anunderground source (UAr) in its inner detector, with half serving astarget in a dual-phase time projection chamber (TPC). The UArcryogenics system must maintain stable thermodynamic conditionsthroughout the experiment's lifetime of over10 years. Continuous removal ofimpurities and radon from the UAr is essential for maximising signalyield and mitigating background. We are developing an efficient andpowerful cryogenics system with a gas purification loop with atarget circulation rate of1000 slpm. Central to itsdesign is a condenser operated with liquid nitrogen which is pairedwith a gas heat exchanger cascade, delivering a combined coolingpower of more than 8 kW. Here wepresent the design choices in view of the DS-20k requirements, inparticular the condenser's working principle and the coolingcontrol, and we show test results obtained with a dedicatedbenchmarking platform at CERN and LNGS. We find that the thermalefficiency of the recirculation loop, defined in terms of nitrogenconsumption per argon flow rate, is95 % and the pressure in the testcryostat can be maintained within±(0.1–0.2) mbar. Wefurther detail a 5-day cool-down procedure of the test cryostat,maintaining a cooling rate typically within-2 K/h, as required for theDS-20k inner detector. Additionally, we assess the circuit's flowresistance, and the heat transfer capabilities of two heat exchangergeometries for argon phase change, used to provide gas forrecirculation. We conclude by discussing how our findings influencethe finalisation of the system design, including necessarymodifications to meet requirements and ongoing testing activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC

The 3×1×1 m3 demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performance of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CACTUS: A depleted monolithic active timing sensor using a CMOS radiation hard technology

The planned luminosity increase at the Large Hadron Collider in the coming years has triggered interest in the use of the particles' time of arrival as additional information in specialized detectors to mitigate the impact of pile-up. The required time resolution is of the order of tens of picoseconds, with a spatial granularity of the order of 1 mm. A time measurement at this precision level will also be of interest beyond the LHC and beyond high energy particle physics. We present in this paper the first developments towards a radiation hard Depleted Monolithic Active Pixel Sensor (DMAPS), with high-resolution time measurement capability. The technology chosen is a standard high voltage CMOS process, in conjunction with a high resistivity detector material, which has already proven to efficiently detect particles in tracking applications after several hundred of Mrad of irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strong-field nonsequential double photoionization using virtual-detector theory with path summation

We present an ab initio study of the nonsequential strong-field ionization dynamics of a model two-electron atom with helium character. Single- and double-ionization events are characterized and displayed using detector signals extracted at different points in the two-electron two-dimensional space. The double photoelectron momentum distribution is calculated via coherent path-summation over virtual-particle trajectories. A comparison is made between the momentum distributions obtained with the virtual-detector method, the Schrödinger wave function, and the time-dependent surface flux method developed by Tao and Scrinzi [New J. Phys. 14, 013021 (2012)]. Insights into different ionization and electron recollision pathways are gained from detailed virtual-particle tracking and energy-time readouts. Furthermore, this study demonstrates the extension of virtual-detector theory to strong-field multielectron quantum dynamics and highlights the importance of the evolving quantum phase in quasiclassical electron propagation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

LBNF/DUNE Cryostats and Cryogenics Infrastructure for the DUNE Far Detector (Design Report)

DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on both a near detector and a cryogenic far detector. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines many tens-of-kilotons of fiducial mass with sub-centimeter spatial resolution to collect neutrino events and image them with high precision. Given its size, this detector will be implemented as a set of up to four modules, each of which will require its own cryostat that will contain approximately 17.5 metric kilotons of ultra-pure liquid argon (LAr). The cryogenics infrastructure to support the detector modules includes systems to receive, transfer, store, purify, and maintain the LAr. This design report describes the cryostats and the cryogenics infrastructure required for the first two detector modules; this infrastructure is designed to support expansion to up to four far detector modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of SPND Material Candidates for Real-Time Neutron Spectrum Monitoring Poster

The future of the nuclear industry will be shaped by advanced reactor designs requiring innovative instrumentation for safe operation. A key area of innovation is the ability to accurately and reliably monitor the neutron energy spectrum during operations, which would also enhance the experimental capabilities of existing research reactors. To address this need, our research focuses on the potential use of Self-Powered Neutron Detectors (SPNDs) for real-time neutron spectrum monitoring. We investigated various candidate materials for SPNDs by evaluating their energy-dependent reaction rates. Promising materials were further modeled using MCNP to determine the free electron production per neutron across the neutron energy spectrum, approximating their energy-dependent signal sensitivity. Our findings identified Samarium (Sm) and Gadolinium (Gd) as top candidates for thermal neutrons, Hafnium (Hf) and Thulium (Tm) for epithermal neutrons, and Tantalum (Ta) for fast neutrons. These materials will undergo future experimental validation to confirm the modeled responses and assess their feasibility for real-time neutron spectrum measurements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Time-resolved diffusion tomographic imaging in highly scattering turbid media

A method for imaging objects in highly scattering turbid media. According to one embodiment of the invention, the method involves using a plurality of intersecting source/detectors sets and time-resolving equipment to generate a plurality of time-resolved intensity curves for the diffusive component of light emergent from the medium. For each of the curves, the intensities at a plurality of times are then inputted into the following inverse reconstruction algorithm to form an image of the medium: X.sup.(k+1).spsp.T =?Y.sup.T W+X.sup.(k).spsp.T .LAMBDA.!?W.sup.T W+.LAMBDA.!.sup.-1 wherein W is a matrix relating output at detector position r.sub.d, at time t, to source at position r.sub.s, .LAMBDA. is a regularization matrix, chosen for convenience to be diagonal, but selected in a way related to the ratio of the noise, to fluctuations in the absorption (or diffusion) X.sub.j that we are trying to determine: .LAMBDA..sub.ij =.lambda..sub.j .delta..sub.ij with .lambda..sub.j = /<.DELTA.Xj.DELTA.Xj> Here Y is the data collected at the detectors, and X.sup.k is the kth iterate toward the desired absoption information.

Alfano, Robert R.↗

Rocks, water, and noble liquids: Unfolding the flavor contents of supernova neutrinos

Measuring core-collapse supernova neutrinos, both from individual supernovae within the Milky Way and from past core collapses throughout the Universe (the diffuse supernova neutrino background, or DSNB), is one of the main goals of current and next generation neutrino experiments. Detecting the heavy-lepton flavor (muon and tau types, collectively v x ) component of the flux is particularly challenging due to small statistics and large backgrounds. Further, while the next galactic neutrino burst will be observed in a plethora of neutrino channels, allowing us to measure a small number of v x events, only upper limits are anticipated for the diffuse v x flux even after decades of data taking with conventional detectors. However, paleo detectors could measure the time-integrated flux of neutrinos from galactic core-collapse supernovae via flavor-blind neutral current interactions. In this work, we show how combining a measurement of the average galactic core-collapse supernova flux with paleo detectors and measurements of the DSNB electron-type neutrino fluxes with the next-generation water Cherenkov detector Hyper-Kamiokande and the liquid noble gas detector DUNE will allow to determine the mean supernova vx flux parameters with precision of order ten percent. Realizing this potential requires both the cosmic supernova rate out to z~1 and the integrated Galactic supernova rate over the last ~1 Gyr to be established at the ~10% level.

79 ASTRONOMY AND ASTROPHYSICS↗

Tomographic Reconstruction of the Neutron Time-Energy Spectrum from a Dense Plasma Focus

A dense plasma focus (DPF) nuclear fusion device is an attractive pulsed neutron source in many applications, due to its relatively large neutron yield, produced in a short time duration. In order to design a DPF that generates neutrons within a specified time profile, or generates a neutron energy spectrum with specific properties, it is necessary to be able to characterize and model the results of the fusion process releasing the neutrons. The time-energy spectrum of fusion neutrons is an ideal quantity to use to validate multiphysics codes that simulate the pinch and fusion processes, because it is a quantity that requires the physics of each of the stages leading up to and ending in the fusion reaction to be simulated correctly. In particular, since DPF fusion neutrons are not monoenergetic -- and there can often be several fusion pinches creating neutrons -- a computer simulation matching high quality neutron spectrum measurements provides great confidence in the fidelity of the simulation. In order to make such a comparison, it is first necessary to have quality measurements from which to infer the spectrum. In this work we pose neutron spectroscopy as the classical tomographic inverse problem from neutron time of flight data at multiple distances, but enhanced by using an additional measurement of the time profile of the fusion pinch near its source and by using detector pairs set up in a geometry that allows for scatter background subtraction. The detector pairs enhance the quality of the time of flight measurements, and the additional constraint posed by the measured time profile allows for reconstructions discretized as finely as the time measurements and in energy as finely as 100 keV, without the problem being underdetermined. We present results from a Deuterium-fueled DPF at the U.S. Department of Energy's Nevada National Security Site and show that we can infer the time-energy spectrum from our measurements for both single and multi-pinch fusion reactions with equal fidelity.

Catenacci, Jared↗