SEARCH · Engineering Papers
Results for “time source”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
NARROWBAND GYROSYNCHROTRON BURSTS: PROBING ELECTRON ACCELERATION IN SOLAR FLARES
Recently, in a few case studies we demonstrated that gyrosynchrotron microwave emission can be detected directly from the acceleration region when the trapped electron component is insignificant. For the statistical study reported here, we have identified events with steep (narrowband) microwave spectra that do not show a significant trapped component and, at the same time, show evidence of source uniformity, which simplifies the data analysis greatly. Initially, we identified a subset of more than 20 radio bursts with such narrow spectra, having low- and high-frequency spectral indices larger than three in absolute value. A steep low-frequency spectrum implies that the emission is nonthermal (for optically thick thermal emission, the spectral index cannot be steeper than two), and the source is reasonably dense and uniform. A steep high-frequency spectrum implies that no significant electron trapping occurs, otherwise a progressive spectral flattening would be observed. Roughly half of these radio bursts have RHESSI data, which allow for detailed, joint diagnostics of the source parameters and evolution. Based on an analysis of radio-to-X-ray spatial relationships, timing, and spectral fits, we conclude that the microwave emission in these narrowband bursts originates directly from the acceleration regions, which have a relatively strong magnetic field, high density, and low temperature. In contrast, the thermal X-ray emission comes from a distinct loop with a smaller magnetic field, lower density, but higher temperature. Therefore, these flares likely occurred due to interaction between two (or more) magnetic loops.
Open Source Tools for High Performance Quasi-Static-Time-Series Simulation Using Parallel Processing.
Abstract not provided.
Real-Time Simultaneous 3D Volumetric Imaging and Mapping of Gamma-ray and Neutron Sources
The invention combines radiation detection instrumentation, data processing algorithms, and visualization software to enable, for the first time ever, simultaneous, real-time imaging of both gamma ray and neutron sources (fast and slow). Radiation detectors sensitive to gamma rays and neutrons are integrated with readout electronics that allow discriminated particles to be incorporated into real-time 3D volumetric reconstructions as two separate data streams. Using the Scene Data Fusion (SDF) conceptual framework and contextual sensors from the Localization and Mapping Platform (LAMP) developed at LBNL, gamma-ray and neutron data are fused onto contextual information from the environment around the detection system. The invention is compatible with radiation detection media capable of detecting and discriminating between gamma rays and neutrons or the pairing of multiple detectors separately capable of detecting gamma rays and/or neutrons. It can be integrated into a compact, lightweight imaging platform for operation as a hand-carry device, on unmanned aerial systems, and with unmanned vehicles. The ability to measure neutron enables the detection and 3D localization of shielded nuclear materials such as Pu-239 which is not possible with means of gamma-ray detection and spectroscopy overcoming of major limitation in the detection of such materials to-date.
Tunable isolated attosecond X-ray pulses with gigawatt peak power from a free-electron laser
The quantum-mechanical motion of electrons in molecules and solids occurs on the sub-femtosecond timescale. Consequently, the study of ultrafast electronic phenomena requires the generation of laser pulses shorter than 1 fs and of sufficient intensity to interact with their target with high probability. Probing these dynamics with atomic-site specificity requires the extension of sub-femtosecond pulses to the soft X-ray spectral region. Here, we report the generation of isolated soft X-ray attosecond pulses with an X-ray free-electron laser. Our source has a pulse energy that is millions of times larger than any other source of isolated attosecond pulses in the soft X-ray spectral region, with a peak power exceeding 100 GW. This unique combination of high intensity, high photon energy and short pulse duration enables the investigation of electron dynamics with X-ray nonlinear spectroscopy and single-particle imaging, unlocking a path towards a new era of attosecond science.
Multiple monopolar outflows driven by massive protostars in IRAS 18162-2048
In this article, we present Combined Array for Research in Millimeter-wave Astronomy (CARMA) 3.5 mm observations and SubMillimeter Array (SMA) 870 μm observations toward the high-mass star-forming region IRAS 18162-2048, which is the core of the HH 80/81/80N system. Molecular emission from HCN, HCO{sup +}, and SiO traces two molecular outflows (the so-called northeast and northwest outflows). These outflows have their origin in a region close to the position of MM2, a millimeter source known to harbor two protostars. For the first time we estimate the physical characteristics of these molecular outflows, which are similar to those of 10{sup 3}-5 × 10{sup 3} L {sub ☉} protostars, and suggest that MM2 harbors high-mass protostars. High-angular resolution CO observations show an additional outflow due southeast. Also for the first time, we identify its driving source, MM2(E), and see evidence of precession. All three outflows have a monopolar appearance, but we link the NW and SE lobes, and explain their asymmetric shape as being a consequence of possible deflection.
A search for time-dependent astrophysical neutrino emission with icecube data from 2012 to 2017
High-energy neutrinos are unique messengers of the high-energy universe, tracing the processes of cosmic ray acceleration. This work presents analyses focusing on time-dependent neutrino point-source searches. A scan of the whole sky, making no prior assumption about source candidates, is performed, looking for a space and time clustering of high-energy neutrinos in data collected by the IceCube Neutrino Observatory between 2012 and 2017. No statistically significant evidence for a time-dependent neutrino signal is found with this search during this period, as all results are consistent with the background expectation. Within this study period, the blazar 3C 279, showed strong variability, inducing a very prominent gamma-ray flare observed in 2015 June. This event motivated a dedicated study of the blazar, which consists of searching for a time-dependent neutrino signal correlated with the gamma-ray emission. No evidence for a time-dependent signal is found. Hence, an upper limit on the neutrino fluence is derived, allowing us to constrain a hadronic emission model.
Effects of mass reduction, flow reduction and enhanced biodecay of DNAPL source zones
A mathematical model and an analytical solution are presented to describe field-scale dense non-aqueous phase liquid (DNAPL) source dissolution and source zone biodecay rates coupled with advective-dispersive dissolved plume transport. The model is employed to investigate various source remediation options on source zone mass depletion, net source mass flux, and dissolved plume attenuation for different source zone 'architectures' (i.e., pools versus residual DNAPL) and compliance criteria. Remediation options considered include partial source mass removal, source flow reduction, and source zone enhanced biodecay. Partial mass reduction reduces the source zone mass flux and downgradient concentrations for residual DNAPL sources and pools, which can significantly reduce dissolved plume size and time to reach compliance criteria. Source zone flow reduction decreases the rate of source mass depletion, but can facilitate compliance, if concentrations at compliance locations are not too high initially. Increase in source biodecay rate, especially with concomitant increases in dissolution kinetics, can decrease the time to achieve compliance criteria over biodecay alone.
Active workflow system for near real-time extreme-scale science. In: PPAA '14 Proceedings of the first workshop on Parallel programming for analytics applications
In recent years, streaming-based data processing has been gaining substantial traction for dealing with overwhelming data generated by real-time applications, from both enterprise sources and scientific computing. In this work, however, we look at an emerging class of scientific data with Near Real-Time (NRT) requirement, in which data is typically generated in a bursty fashion with the near real-time constraints being applied primarily between bursts, rather than within a stream. A key challenge for this types of data sources is that the processing time per data element is not uniform, and not always feasible to predict. Given the observations on the increasing unpredictability of compute load and system dynamics, this work looks to adapt streaming-based approach to the context of this new class of large experiments and simulations that have complex run-time control and analysis issues. In particular, we deploy a novel two-tier scheme for handling the increasing unpredictability of runtime behaviors: Instead of relying on determining what and where to run the scientific workflows beforehand or partial dynamically, the decision will also be adaptively enhanced online according to system runtime status. This is enabled by embedding workflow along with data streams. Specifically, we break data outputs generated from experiments or simulations into multiple self-describing "chunks", which we call active data objects. As such, if there is a transient hotspot observed, a data object with unfinished workflow pipeline can break its previous schedule and search for a least loaded location to continue the execution. Our preliminary experiment results based on synthetic workloads demonstrate the proposed active workflow system as a very promising solution by outperforming the state-of-the-art semi-dynamic workflow schedulers with an improved workflow completion time, as well as a good scalability.
Characterization of LAPPD timing at CERN PS testbeam
Large Area Picosecond PhotoDetectors (LAPPDs) are photosensors based on microchannel plate technology with about 400 cm 2 sensitive area. The external readout plane of a capacitively coupled LAPPD can be segmented into pads providing a spatial resolution down to 1 mm scale. The LAPPD signals have about 0.5 ns rise time followed by a slightly longer fall time and their amplitude reaches a few dozens of mV per single photoelectron. In this article, we report on the measurement of the time resolution of an LAPPD prototype in a test beam exercise at CERN PS. Most of the previous measurements of LAPPD time resolution had been performed with laser sources. In this article we report time resolution measurements obtained through the detection of Cherenkov radiation emitted by high energy hadrons. Our approach has been demonstrated capable of measuring time resolutions as fine as 25-30 ps. The available prototype had performance limitations, which prevented us from applying the optimal high voltage setting. Finally, the measured time resolution for single photoelectrons is about 80 ps r.m.s.
A Mo-anode-based in-house source for small-angle X-ray scattering measurements of biological macromolecules
We demonstrate the use of a molybdenum-anode-based in-house small-angle X-ray scattering (SAXS) setup to study biological macromolecules in solution. Our system consists of a microfocus X-ray tube delivering a highly collimated flux of 2.5 × 10{sup 6} photons/s at a beam size of 1.2 × 1.2 mm{sup 2} at the collimation path exit and a maximum beam divergence of 0.16 mrad. The resulting observable scattering vectors q are in the range of 0.38 Å{sup −1} down to 0.009 Å{sup −1} in SAXS configuration and of 0.26 Å{sup −1} up to 5.7 Å{sup −1} in wide-angle X-ray scattering (WAXS) mode. To determine the capabilities of the instrument, we collected SAXS data on weakly scattering biological macromolecules including proteins and a nucleic acid sample with molecular weights varying from ∼12 to 69 kDa and concentrations of 1.5–24 mg/ml. The measured scattering data display a high signal-to-noise ratio up to q-values of ∼0.2 Å{sup −1} allowing for an accurate structural characterization of the samples. Moreover, the in-house source data are of sufficient quality to perform ab initio 3D structure reconstructions that are in excellent agreement with the available crystallographic structures. In addition, measurements for the detergent decyl-maltoside show that the setup can be used to determine the size, shape, and interactions (as characterized by the second virial coefficient) of detergent micelles. This demonstrates that the use of a Mo-anode based in-house source is sufficient to determine basic geometric parameters and 3D shapes of biomolecules and presents a viable alternative to valuable beam time at third generation synchrotron sources.
Improved Acquisition and Reconstruction for Wavelength-Resolved Neutron Tomography
Wavelength-resolved neutron tomography (WRNT) is an emerging technique for characterizing samples relevant to the materials sciences in 3D. WRNT studies can be carried out at beam lines in spallation neutron or reactor-based user facilities. Because of the limited availability of experimental time, potential imperfections in the neutron source, or constraints placed on the acquisition time by the type of sample, the data can be extremely noisy resulting in tomographic reconstructions with significant artifacts when standard reconstruction algorithms are used. Furthermore, making a full tomographic measurement even with a low signal-to-noise ratio can take several days, resulting in a long wait time before the user can receive feedback from the experiment when traditional acquisition protocols are used. In this paper, we propose an interlaced scanning technique and combine it with a model-based image reconstruction algorithm to produce high-quality WRNT reconstructions concurrent with the measurements being made. The interlaced scan is designed to acquire data so that successive measurements are more diverse in contrast to typical sequential scanning protocols. The model-based reconstruction algorithm combines a data-fidelity term with a regularization term to formulate the wavelength-resolved reconstruction as minimizing a high-dimensional cost-function. Using an experimental dataset of a magnetite sample acquired over a span of about two days, we demonstrate that our technique can produce high-quality reconstructions even during the experiment compared to traditional acquisition and reconstruction techniques. In summary, the combination of the proposed acquisition strategy with an advanced reconstruction algorithm provides a novel guideline for designing WRNT systems at user facilities.
Results from laboratory tests of the two-dimensional Time-Encoded Imaging System.
A series of laboratory experiments were undertaken to demonstrate the feasibility of two dimensional time-encoded imaging. A prototype two-dimensional time encoded imaging system was designed and constructed. Results from imaging measurements of single and multiple point sources as well as extended source distributions are presented. Time encoded imaging has proven to be a simple method for achieving high resolution two-dimensional imaging with potential to be used in future arms control and treaty verification applications.
Observational window effects on multi-object reverberation mapping
ABSTRACT Contemporary reverberation mapping campaigns are employing wide-area photometric data and high-multiplex spectroscopy to efficiently monitor hundreds of active galactic nuclei (AGNs). However, the interaction of the window function(s) imposed by the observation cadence with the reverberation lag and AGN variability time-scales (intrinsic to each source over a range of luminosities) impact our ability to recover these fundamental physical properties. Time dilation effects due to the sample source redshift distribution introduce added complexity. We present comprehensive analysis of the implications of observational cadence, seasonal gaps, and campaign baseline duration (i.e. the survey window function) for reverberation lag recovery. We find that the presence of a significant seasonal gap dominates the efficacy of any given campaign strategy for lag recovery across the parameter space, particularly for those sources with observed-frame lags above 100 d. Using the Australian Dark Energy Survey as a baseline, we consider the implications of this analysis for the 4MOST/Time-Domain Extragalactic Survey campaign providing concurrent follow-up of the Legacy Survey of Space and Time deep-drilling fields, as well as upcoming programmes. We conclude that the success of such surveys will be critically limited by the seasonal visibility of some potential field choices, but show significant improvement from extending the baseline. Optimizing the sample selection to fit the window function will improve survey efficacy.
BrachyView, A novel inbody imaging system for HDR prostate brachytherapy: Design and Monte Carlo feasibility study
Purpose: High dose rate (HDR) brachytherapy is a form of radiation therapy for treating prostate cancer whereby a high activity radiation source is moved between predefined positions inside applicators inserted within the treatment volume. Accurate positioning of the source is essential in delivering the desired dose to the target area while avoiding radiation injury to the surrounding tissue. In this paper, HDR BrachyView, a novel inbody dosimetric imaging system for real time monitoring and verification of the radioactive seed position in HDR prostate brachytherapy treatment is introduced. The current prototype consists of a 15 Multiplication-Sign 60 mm{sup 2} silicon pixel detector with a multipinhole tungsten collimator placed 6.5 mm above the detector. Seven identical pinholes allow full imaging coverage of the entire treatment volume. The combined pinhole and pixel sensor arrangement is geometrically designed to be able to resolve the three-dimensional location of the source. The probe may be rotated to keep the whole prostate within the transverse plane. The purpose of this paper is to demonstrate the efficacy of the design through computer simulation, and to estimate the accuracy in resolving the source position (in detector plane and in 3D space) as part of the feasibility study for the BrachyView project.Methods: Monte Carlo simulations were performed using the GEANT4 radiation transport model, with a {sup 192}Ir source placed in different locations within a prostate phantom. A geometrically accurate model of the detector and collimator were constructed. Simulations were conducted with a single pinhole to evaluate the pinhole design and the signal to background ratio obtained. Second, a pair of adjacent pinholes were simulated to evaluate the error in calculated source location.Results: Simulation results show that accurate determination of the true source position is easily obtainable within the typical one second source dwell time. The maximum error in the estimated projection position was found to be 0.95 mm in the imaging (detector) plane, resulting in a maximum source positioning estimation error of 1.48 mm.Conclusions: HDR BrachyView is a feasible design for real-time source tracking in HDR prostate brachytherapy. It is capable of resolving the source position within a subsecond dwell time. In combination with anatomical information obtained from transrectal ultrasound imaging, HDR BrachyView adds a significant quality assurance capability to HDR brachytherapy treatment systems.
Observations of 14 CO 2 in ecosystem respiration from a temperate deciduous forest in Northern Wisconsin
We show that the 14 CO 2 composition of plant and soil respiration can be used to determine the residence time of photosynthetically fixed carbon before it is released back to the atmosphere. To estimate the residence time of actively cycled carbon in a temperate forest, we employed two approaches for estimating the Δ 14 CO 2 of ecosystem respiration (Δ 14 C-R eco ) at the Willow Creek AmeriFlux site in Northern Wisconsin, USA. Our first approach was to construct nighttime Keeling plots from subcanopy profiles of Δ 14 CO 2 and CO 2 , providing estimates of Δ 14 C-R eco of 121.7‰ in June and 42.0‰ in August 2012. These measurements are likely dominated by soil fluxes due to proximity to the ground level. Our second approach utilized samples taken over 20 months within the forest canopy and from 396 m above ground level at the nearby LEF NOAA tall tower site (Park Falls, WI). In this canopy-minus-background approach we employed a mixing model described by Miller and Tans (2003) for estimating isotopic sources by subtracting time-varying background conditions. For the period from May 2011 to December 2012 the estimated Δ 14 C-R eco using the Miller-Tans model was 76.8‰. Together, these Δ 14 C-R eco values represent mean R eco carbon ages of approximately 1–19 years. We also found that heterotrophic soil-respired Δ 14 C at Willow Creek was 5–38‰ higher (i.e., 1–10 years older) than predicted by the Carnegie-Ames-Stanford Approach global biosphere carbon model for the 1 × 1 pixel nearest to the site. Finally, this study provides much needed observational constraints of ecosystem carbon residence times, which are a major source of uncertainty in terrestrial carbon cycle models.
Nuclear reactor transient analysis via a quasi-static kinetics Monte Carlo method
The predictor-corrector quasi-static (PCQS) method is applied to the Monte Carlo (MC) calculation for reactor transient analysis. To solve the transient fixed-source problem of the PCQS method, fission source iteration is used and a linear approximation of fission source distributions during a macro-time step is introduced to provide delayed neutron source. The conventional particle-tracking procedure is modified to solve the transient fixed-source problem via MC calculation. The PCQS method with MC calculation is compared with the direct time-dependent method of characteristics (MOC) on a TWIGL two-group problem for verification of the computer code. Then, the results on a continuous-energy problem are presented.
Global threat reduction initiative efforts to address transportation challenges associated with the recovery of disused radioactive sealed sources - 10460
Proper disposition of disused radioactive sources is essential for their safe and secure management and necessary to preclude their use in malicious activities. Without affordable, timely transportation options, disused sealed sources remain in storage at hundreds of sites throughout the country and around the world. While secure storage is a temporary measure, the longer sources remain disused or unwanted the chances increase that they will become unsecured or abandoned. The Global Threat Reduction Initiative's Off-Site Source Recovery Project (GTRIlOSRP), recovers thousands of disused and unwanted sealed sources annually as part of GTRl's larger mission to reduce and protect high risk nuclear and radiological materials located at civilian sites worldwide. Faced with decreasing availability of certified transportation containers to support movement of disused and unwanted neutron- and beta/gamma-emitting radioactive sealed sources, GTRIlOSRP has initiated actions to ensure the continued success of the project in timely recovery and management of sealed radioactive sources. Efforts described in this paper to enhance transportation capabilities include: {sm_bullet} Addition of authorized content to existing and planned Type B containers to support the movement of non-special form and other Type B-quantity sealed sources; {sm_bullet} Procurement of vendor services for the design, development, testing and certification of a new Type B container to support transportation of irradiators, teletherapy heads or sources removed from these devices using remote handling capabilities such as the IAEA portable hot cell facility; {sm_bullet} Expansion of shielded Type A container inventory for transportation of gamma-emitting sources in activity ranges requiring use of shielding for conformity with transportation requirements; {sm_bullet} Approval of the S300 Type A fissile container for transport of Pu-239 sealed sources internationally; {sm_bullet} Technology transfer of field-sealable (non-welded) special form capsules for commercial use.