Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

SansEC: A New Dimension to Sensing Electrical Sensors with No Electrical Connections

This DVD contains an introduction to SansEC, a new electrical sensor technology without electrical connections. This new class of sensors represents a stand-alone 2-dimensional geometric pattern of electrically open circuits without electrical connections. The sensor is powered with an external, harmonic magnetic field and as the property being sensed changes, responds to frequency, amplitude or bandwidth changes. This response is interrogated using an external antenna, a single electrical component having no electrical connections. The sensor can be encased in any nonconductive material to provide protection from its environment. If the container is nonconductive, the sensor can be placed external to the container without contacting it, making installation very simple. An encased sensor can also be placed inside a container for measuring the level of any fluid or material, including acids. Any readout device can be used with the sensor, including standard or digital gauges. SansEC sensors can be used to measure real-time fluid slosh to determine if a fuel tank's internal structural isogrid can be used to replace some of the baffles surface, thus reducing the overall baffle weight and giving a better understanding of the effect that isogrids have on fluid motion. Any SansEC sensor can also be used for damage or tamper detection. When damaged, torn or tampered with, the measured response shift in frequency is commensurate to the detected damage, with the response frequency increasing with rising damage. The unique sensor design allows it to function even if damaged, because unlike other circuits, there is no single point on the sensor that, if damaged, renders it non-functional. The broad metallic coverage of the array allows the array to be one of many thermal insulation layers. Two such arrays were tested to understand the effects of high velocity damage. Each test article was targeted with metal projectiles emulating micrometeorite or orbital debris impact. Even with the damage that the sensors received every sensor was still functional with the new response baseline, and remained capable of detecting even more damage.

Source record↗

GBT Detection of Polarization-Dependent HI Absorption and HI Outflows in Local ULIRGs and Quasars

We present the results of a 21-cm HI survey of 27 local massive gas-rich late-stage mergers and merger remnants with the Green Bank Telescope (GBT). These remnants were selected from the Quasar/ULIRG Evolution Study (QUEST) sample of ultraluminous infrared galaxies (ULIRGs; L(sub 8 - 1000 micron) > 10(exp 12) solar L) and quasars; our targets are all bolometrically dominated by active galactic nuclei (AGN) and sample the later phases of the proposed ULIRG-to-quasar evolutionary sequence. We find the prevalence of HI absorption (emission) to be 100% (29%) in ULIRGs with HI detections, 100% (88%) in FIR-strong quasars, and 63% (100%) in FIR-weak quasars. The absorption features are associated with powerful neutral outflows that change from being mainly driven by star formation in ULIRGs to being driven by the AGN in the quasars. These outflows have velocities that exceed 1500 km/s in some cases. Unexpectedly, we find polarization-dependent HI absorption in 57% of our spectra (88% and 63% of the FIR-strong and FIR-weak quasars, respectively). We attribute this result to absorption of polarized continuum emission from these sources by foreground HI clouds. About 60% of the quasars displaying polarized spectra are radio-loud, far higher than the approx 10% observed in the general AGN population. This discrepancy suggests that radio jets play an important role in shaping the environments in these galaxies. These systems may represent a transition phase in the evolution of gas-rich mergers into "mature" radio galaxies.

Teng, Stacy H.↗

Biases In A Magnitude Limited Versus A Distant Limited Planet Search

All methods utilized to conduct a search or survey inevitably have some built-in biases. These biases are often traced to some limitation of the instrument used or some inherent character of the signal being recorded. We address these limitations for various methods used or proposed for planet detection: spectroscopy, astrometry, interferometry, and photometry. For spectroscopy, the turbulence in the photosphere limits the minimum measurable dossier velocity to 3 m/s and hence the minimum planet to star mass ratio, thereby favoring massive close-in planets. Limited available observing time will necessarily introduce additional selection biases in the targets observed and telescope aperture will limit the faintest magnitude stars to be measured; For astrometry, the angular resolution of the instrument along with motions in the photometric center of the star limit the furthest distance for which giant planets can be detected to about 10 pc and favor massive outer orbit planets around low mass non-solar like stars; For imaging interferometry, the minimum angular size of the central null limits both the distance to the star and closeness of the planet to the host star to about 1 AU at 10 pc and thus to the very few solar-like stars within 10 pc. Solar and extra-solar zodiacal emission will limit the minimum size of the detectable planet. For photometry, the inherent variability of the star does not limit the minimum planet size until earth-sized or smaller planets are considered around solar-like stars. The telescope aperture limits the faintest stars that can be monitored. As with spectroscopy, there is no inherent distant limit to the method. After addressing the limiting factors of each method, an estimate is made of the number of planets of various sizes that could be found for each stellar type based on the detection probability and the number of stars that can be searched for planets.

Koch, David↗

First-results from the Perseverance SHERLOC Investigation: Aqueous Alteration Processes and Implications for Organic Geochemistry in Jezero Crater, Mars

The Perseverance rover landed in Jezero crater, a site selected to fulfill the Mars-2020 mission goals of characterizing the geology of habitable environments and searching for signs of life while collecting samples for return to Earth [1]. Jezero hosted an open-basin lake during the late Noachian/early Hesperian (~3.7 Ga) [1-2], has units associated with the largest carbonate deposit identified on Mars [3-4], and has a well-preserved delta with clay and carbonate-bearing sediments, well-suited to preservation of organics [1,3-4]. Investigating the nature of organics and aqueous environments within their geologic con-text allows us to understand important aqueous processes and determine habitability within Jezero crater. Previous in situ landed measurements of organics could not resolve their spatial and mineralogical con-text [5-6]. Although Martian meteorites lack geological context, the spatial distribution of organic compounds in Martian meteorites have allowed recognition of an association between aqueous processes and organics [7-8]. Here, we show for the first time in-situ associations between carbonate-forming ultramafic alteration process, later stage aqueous sulfate and perchlorate formation, and organics on the Martian surface. Methodology and geological context: We use the Perseverance rover’s SHERLOC instrument (Scanning Habitable Environments with Raman and Lumines-ence of Organics and Chemicals), a deep-ultraviolet fluorescence and Raman scattering spectrometer capable of mapping the organic and mineral composition with a spatial resolution of 100 μm resolution to report the presence of organics and aqueously formed minerals at Jezero crater [9]. These spectral detections were compared with co-located images obtained with the autofocus context imager (ACI) and the WATSON camera for textural analysis [9]. As of writing, the Per-severance rover has abraded five targets that were measured with the SHERLOC instrument. The five targets are located in two different orbitally-identified geological units within the floor of Jezero crater; the Crater Floor Fractured Rough unit (CF-Fr) and the Séítah region within the Crater Floor Fractured 1 unit (CF-F1) [10]. In orbital infrared spectroscopic data, the CF-Fr unit is associated with pyroxene spectral signatures and minor alteration, while the Séítah region is associated with olivine and minor Mg-rich carbonates and clays [3-4,10]. Carbonation of ultramafic protolith recorded within Jezero crater: All scans of abraded targets within the Séítah region reveal strong peaks at 1080–1090 cm−1 consistent with carbonate and peak singlets or doublets at 820–840 cm−1 attributed to olivine (Fig. 1), consistent with orbital infrared observations. Our detailed micron-scale petrographic and spectroscopic evidence shows that these carbonates formed through carbonation of an ultramafic protolith. The supporting observations include: (1) Carbonate cation compositions match those of olivine, suggesting mixed Fe- and Mg-olivine gave rise to mixed Fe- and Mg-carbonates, similar to observations of ultramafic systems on Earth and within Martian meteorites [3-4,7-8]. (2) The ob-served carbonates co-occur with hydrated materials, gypsum, and potentially aqueously-formed phases, amorphous silicates and phosphate. (3) The spectral and textural variation of olivine and carbonate dominated zones and olivine-carbonate mixtures within both primary grains and interstitial zones are expected for carbonated ultramafic protoliths. (4) These mineral associations and textures closely resemble those observed within the ALH84001 and Nakhlite meteorites attributed to olivine carbonation on Mars [6-7]. Taken together, micron-scale SHERLOC documentation of these phenomena bridge previous orbital and meteorite observations and demonstrate in-situ regionally extensive (~106 km2) ultramafic alteration resulting in geo-logical deposition of carbonates. Furthermore, we observe that olivine carbonation was involved in preserving and possibly synthesizing organics, which makes this environment potentially habitable, as previously suggested in [1,3-4] (Fig. 1). Late-stage aqueous perchlorate and sulfate in Jezero crater: An abrasion target within the CF-Fr unit contains combinations of high intensity 950-955 cm−1 peaks and minor 1090-1095 cm−1 and 1150-1155 cm−1 peaks that are spectral fits to anhydrous perchlorate (Fig. 1). Some spectra show a combination of 950-955 cm−1 peaks with equally strong 1010-1020 cm−1 peaks, low intensity broad features at 1120 cm−1, and occasional broad 3450 cm−1 hydration (-OH) features, indicating a mixture of Ca-sulfate and perchlorate that is minimally hydrated (Fig. 1). The detections of per-chlorates within Jezero crater differ from previous measurements (e.g. Phoenix lander, Curiosity rover, Tissint meteorite [7,11]) because they are observed to be intimately related to aqueous processes including sulfate formation, they present as a secondary white void-fill occurring within the interior of the rock, and they are found to likely be Na-perchlorate. implications for their formation: Three different types of organics embedded within three different lithologies were observed within the abraded targets. Organics associated with low intensity ~340 nm fluorescence were widespread within targets with no apparent association to particular minerals (Fig. 1). Organics associated with ~305 nm and ~275 nm fluorescence correlated with sulfates within the Bellegarde target in the CF-Fr unit, while organics associated with high intensity ~340 nm fluorescence correlated with carbonate, phosphate, and amorphous silicate mixtures within the Garde target in the Séítah region (Fig. 1). Although assignment of fluorescence signatures to specific organic compounds is not conclusive, ~340 nm fluorescence is generally more consistent with 2-ring aromatic organics, ~275 nm fluorescence is more consistent with 1-ring aromatic organics, and ~305 nm fluorescence can be created by either 2- or 1-ring aromatics [12]. These observations indicate that the strongest fluorescence signatures interpreted as organics were found in materials associated with aqueous processes, i.e. sulfate- and carbonate-bearing materials, suggesting both brines and ultramafic carbonation aqueous environments were capable of preserving organics on ancient Mars. In Martian meteorites, simple aromatic organics proposed to have been synthesized through aqueous processes can be found within minerals associated with olivine carbonation and in spatial association with perchlorate and sulfate materials [7-8], similar to SHERLOC observations. Hence, we advance an abiotic aqueous synthesis origin for the organics although we cannot rule out the presence of organics from meteoritic in-fall or putative organic biosignatures. Detailed analyses will be required upon return of these materials to Earth.

E L Scheller↗

Thermal neutron image intensifier tube provides brightly visible radiographic pattern

Vacuum-type neutron image intensifier tube improves image detection in thermal neutron radiographic inspection. This system converts images to an electron image, and with electron acceleration and demagnification between the input target and output screen, produces a bright image viewed through a closed circuit television system.

Berger, H.↗

The use of radar and LANDSAT data for mineral and petroleum exploration in the Los Andes region, Venezuela

A geological study of a 27,500 sq km area in the Los Andes region of northwestern Venezuela was performed which employed both X-band radar mosaics and computer processed Landsat images. The 3.12 cm wavelength radar data were collected with horizontal-horizontal polarization and 10 meter spatial resolution by an Aeroservices SAR system at an altitude of 12,000 meters. The radar images increased the number of observable suspected fractures by 27 percent over what could be mapped by LANDSAT alone, owing mostly to the cloud cover penetration capabilities of radar. The approximate eight fold greater spatial resolution of the radar images made possible the identification of shorter, narrower fractures than could be detected with LANDSAT data alone, resulting in the discovery of a low relief anticline that could not be observed in LANDSAT data. Exploration targets for petroleum, copper, and uranium were identified for further geophysical work.

Vincent, R. K.↗

Observations of interstellar zinc

The International Ultraviolet Explorer observations of interstellar zinc toward 10 stars are examined. It is found that zinc is at most only slightly depleted in the interstellar medium; its abundance may serve as a tracer of the true metallicity in the gas. The local interstellar medium has abundances that apparently are homogeneous to within a factor of two, when integrated over paths of about 500 pc, and this result is important for understanding the history of nucleosynthesis in the solar neighborhood. The intrinsic errors in detecting weak interstellar lines are analyzed and suggestions are made as to how this error limit may be lowered to 5 mA per target observation.

Jura, M.↗

Development of an apparatus for obtaining molecular beams in the energy range from 2 to 200 eV

The formation and detection of molecular beams obtained by charge exchange from a low-energy ion source is discussed. Dispersion in energy of the ion source was measured and problems concerning detection of neutral beams were studied. Various methods were used, specifically secondary electron emissivity of a metallic surface and ionization of a gas target with a low ionization voltage. The intensities of neutral beams as low as 10 eV are measured by a tubular electron multiplier and a lock-in amplifier.

Clapier, R.↗

Analysis of AIS radiometry at Mono Lake, California

Airborne imaging spectrometer (AIS) data were studied to establish absolute instrumental calibration and to provide atmospheric corrections. Good agreement is found between calculated and measured radiances for uniform surface targets (beaches), but simulations of atmospheric properties with LOWTRAN lead to unreasonably low values of atmospheric precipitable water. Absorptions from CO2 are not detected in the AIS data, but are strongly present in the LOWTRAN model. The apparent low contrast of all atmospheric absorption bands leads to a study of contamination from overlapping spectral orders in the AIS data. The suspected contamination is shown unambiguously to be present beyond 1500 nm. The magnitude remains uncertain. Spectral band filling at 1400 nm cannot be accounted for by order mixing because of the 800 nm blocking filter used. Rough corrections for short wavelength mode observations might be possible if an after-the-fact radiometric calibration of the instrument can be developed.

Conel, J. E.↗

Relativity effects for space-based coherent lidar experiments

An effort was initiated last year in the Astrionics Laboratory at Marshall Space Flight Center to examine and incorporate, if necessary, the effects of relativity in the design of space-based lidar systems. A space-based lidar system, named AEOLUS, is under development at Marshall Space Flight Center and it will be used to accurately measure atmospheric wind profiles. Effects of relativity were also observed in the performance of space-based systems, for example in case of global positioning systems, and corrections were incorporated into the design of instruments. During the last summer, the effects of special relativity on the design of space-based lidar systems were studied in detail, by analyzing the problem of laser scattering off a fixed target when the source and a co-located receiver are moving on a spacecraft. Since the proposed lidar system uses a coherent detection system, errors even in the order of a few microradians must be corrected to achieve a good signal-to-noise ratio. Previous analysis assumed that the ground is flat and the spacecraft is moving parallel to the ground, and developed analytical expressions for the location, direction and Doppler shift of the returning radiation. Because of the assumptions used in that analysis, only special relativity effects were involved. In this report, that analysis is extended to include general relativity and calculate its effects on the design.

Gudimetla, V. S. Rao↗

SPARCLE: Validation of Observing System Simulations (SPace Readiness Coherent Lidar Experiment)

NASA recently approved a mission to fly a Doppler Wind Lidar (DWL) on a U.S. Space Shuttle. SPARCLE, managed by Marshall Space Flight Center in Huntsville, AL, is targeted for launch in March 2001. This mission is viewed as a necessary demonstration of a solid state (2 micron) lidar using coherent detection before committing resources to a 3-5 year research or operational mission. While, to many, this shuttle mission is seen as the first step in a series leading to a fully operational wind observing system, to others, it is a chance to validate predictions of performance based upon theoretical models, analyses of airborne and ground-based data, and sophisticated observing system simulation experiments. This paper will be presented in two parts: first a brief overview of the SPARCLE mission and second, a summary of current performance predictions and key contributions from ground- based and airborne DWL research. The SPARCLE instrument is a 100 mJ, 6 Hz, diode-pumped 2-micron laser with a .25 m telescope using heterodyne mixing in a fiber and an InGaAs detector. A 25 cm silicon wedge scanner will be used in step-stare modes with dwells ranging from 60 seconds to .5 seconds. Pointing knowledge is achieved with a dedicated GPS/INS mounted close to the lidar. NASA's Hitchhiker program is providing the instrument enclosures (2 cans) and mission logistics support. An on-board data system is sized to record 150 Gbytes of raw signal from a two 400 MHZ A/D converters. On-board signal processing will be used to control the frequency of the Local Oscillator. SPARCLE is predicted to have a single shot backscatter sensitivity near 1x10(exp -6) m-1 sr-1, To achieve higher sensitivity, shot accumulation will be employed. Ground-based, 2 micron DWLs have been used to assess the benefits of shot accumulation (approximately SQRT for SNR). Airborne programs like MACAWS have provided good datasets for evaluating various sampling strategies and signal processing algorithms. Using these real data to calibrate our simulation models, we can describe when and how well SPARCLE is expected to preform. Outputs from these performance models will be presented.

Emmitt, G. D.↗

Volcanic Activity at Tvashtar Catena, Io

Tvashtar Catena (63 N, 120 W) is one of the most interesting features on Io. This chain of large paterae (caldera-like depressions) has exhibited highly variable volcanic activity in a series of observations. Tvashtar is the type example of a style of volcanism seen only at high latitudes, with short-lived Pele-type plumes and short-lived by intense thermal events. Evidence for a hot spot at Tvashtar was first detected in an eclipse observation in April 1997 (orbit G7) by the Solid State Imager (SSI) on the Galileo Spacecraft. Tvashtar was originally targeted for observation at higher resolution in the close flyby in November 1999 (I25) because of its interesting large-scale topography. There are relatively few but generally larger paterae at high latitudes on Io. I25 images revealed a 25 km long, 1-2 km high lava curtain via a pattern of saturation and bleeding in the CCD image, which requires very high temperatures.

Milazzo, M. P.↗

Routine detection of Epstein-Barr virus specific T-cells in the peripheral blood by flow cytometry

The ability to detect cytomegalovirus-specific T-cells (CD4(+)) in the peripheral blood by flow cytometry has been recently described by Picker et al. In this method, cells are incubated with viral antigen and responding (cytokine producing) T-cells are then identified by flow cytometry. To date, this technique has not been reliably used to detect Epstein-Barr virus (EBV)-specific T-cells primarily due to the superantigen/mitogenic properties of the virus which non-specifically activate T-cells. By modifying culture conditions under which the antigens are presented, we have overcome this limitation and developed an assay to detect and quantitate EBV-specific T-cells. The detection of cytokine producing T-cells by flow cytometry requires an extremely strong signal (such as culture in the presence of PMA and ionomycin). Our data indicate that in modified culture conditions (early removal of viral antigen) the non-specific activation of T-cells by EBV is reduced, but antigen presentation will continue uninhibited. Using this method, EBV-specific T-cells may be legitimately detected using flow cytometry. No reduction in the numbers of antigen-specific T-cells was observed by the early removal of target antigen when verified using cytomegalovirus antigen (a virus with no non-specific T-cell activation properties). In EBV-seropositive individuals, the phenotype of the EBV-specific cytokine producing T-cells was evaluated using four-color flow cytometry and found to be CD45(+), CD3(+), CD4(+), CD45RA(-), CD69(+), CD25(-). This phenotype indicates the stimulation of circulating previously unactivated memory T-cells. No cytokine production was observed in CD4(+) T-cells from EBV-seronegative individuals, confirming the specificity of this assay. In addition, the use of four color cytometry (CD45, CD3, CD69, IFNgamma/IL-2) allows the total quantitative assessment of EBV-specific T-cells while monitoring the interference of EBV non-specific mitogenic activity. This method may have significant utility for the monitoring of the immune response to latent virus infection/reactivation.

Non-NASA Center↗

The HOSTS Survey-Exozodiacal Dust Measurements for 30 Stars

The Hunt for Observable Signatures of Terrestrial Systems survey searches for dust near the habitable zones (HZs) around nearby, bright main-sequence stars. We use nulling interferometry in the N band to suppress the bright stellar light and to probe for low levels of HZ dust around the 30 stars observed so far. Our overall detection rate is 18%, including four new detections, among which are the first three around Sun-like stars and the first two around stars without any previously known circumstellar dust. The inferred occurrence rates are comparable for early-type and Sun-like stars, but decrease from 60(sup +16)(sub -21)% for stars with previously detected cold dust to 8(sup +10)(sub -3)% for stars without such excess, confirming earlier results at higher sensitivity. For completed observations on individual stars, our sensitivity is five to ten times better than previous results. Assuming a lognormal excess luminosity function, we put upper limits on the median HZ dust level of 13 zodis (95% confidence) for a sample of stars without cold dust and of 26 zodis when focusing on Sun-like stars without cold dust. However, our data suggest that a more complex luminosity function may be more appropriate. For stars without detectable Large Binocular Telescope Interferometer (LBTI) excess, our upper limits are almost reduced by a factor of two, demonstrating the strength of LBTI target vetting for future exo-Earth imaging missions. Our statistics are limited so far, and extending the survey is critical to informing the design of future exo-Earth imaging surveys.

The Hunt for Observable Signatures of Terrestrial ↗

General Services Administration Reclamation Yard, SWMU 010, 2021 Groundwater Monitoring Report

This report presents a summary of the groundwater monitoring activities that occurred in November and December 2021 at General Services Administration Reclamation Yard, Solid Waste Management Unit 010, located at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program. This approach also meets the requirements of Chapter 62-780, Florida Administrative Code. For the purposes of this report, two separate plumes, known as the Polychlorinated Biphenyl (PCB)/Volatile Organic Aromatic (VOA) Plume and the Chlorinated Volatile Organic Compound (VOC) Plume, were identified for this site. The contaminants of concern (COCs) for the PCB/VOA Plume consists of PCBs, 1,2,4-trichlorobenzene, and breakdown products of 1,2,4-trichlorobenzene. The COCs for the Chlorinated VOC Plume are tetrachloroethene, trichloroethene, cis-1,2-dichloroethene, and vinyl chloride. The activities presented in this report include two field events: (1) November 2021 – PCB/VOA Plume groundwater sampling via Direct Push Technology – 70 groundwater samples were collected from 10 locations at varying intervals; and (2) December 2021 – Site-wide semi-annual water level measurements of 54 monitoring wells, redevelopment of 5 monitoring wells, and sampling of 35 monitoring wells. Results for the PCB/VOA plume demonstrated COCs have not rebounded since the 2018 source removal, with groundwater cleanup target levels (GCTLs) exceeded in the 10-30 ft. below ground surface interval only. In the Chlorinated VOC plume area, there were no detections of COCs above a GCTL for at least the second consecutive sampling event for the sampled wells. Cleanup objectives have been met, and it is recommended that VOC monitoring be discontinued. Underground injection control parameters will continue to be monitored in three wells until those analytes return to background concentrations.

GSA Reclamation Yard↗

Development of a Photoacoustic Formaldehyde Monitor

Key indoor air quality pollutant formaldehyde (H2CO) is tracked on International Space Station (ISS) using passive badges returned to the ground periodically for analysis. The process is time-consuming both in preparation and for analysis upon return 6-12 months later. Badges also require precious crew time for deploy, retrieval and stow. As NASA’s focus in space exploration shifts to the Moon and Mars, archival sample return becomes increasingly impractical, so the aim of this project is to develop a highly reliable real-time analyzer for H2CO at low concentrations with data downlinked. Potential sources of H2CO include materials off gassing, use of formalin as a tissue fixative in biological payloads and overheating of acetal polymers. The Spacecraft Maximum Allowable Concentration (SMAC) for H2CO is 100 ppb for exposures of 7 days or longer. ISS concentrations recently run only 10 - 30 ppb but have spiked as high as 60 ppb in the past. Gateway real time monitoring requirements call for a range of 8 - 140 ppb. For this project, a concentration range of 5 - 500 ppb H2CO is targeted. The core tunable diode laser spectroscopy (TDLS) technology was developed by Vista Photonics through the NASA and US Navy Small Business Innovation Research (SBIR) programs. Monitors based on this technology have been demonstrated on ISS, trialed on a nuclear submarine and are in production as Anomaly Gas Analyzers for both ISS and Orion. Initially, direct absorption TDLS was used exclusively in these monitors, however, the H2CO target concentration is much lower, and a longer wavelength required, so a photoacoustic spectroscopy (PAS) technique was adapted, where the laser excitation is detected by a sensitive microphone vs. a conventional photodetector. This paper will discuss the results of NASA-JSC laboratory testing of a prototype PAS based formaldehyde monitor and explore potential adaptations for Gateway missions and beyond.

Paul D Mudgett↗

Detecting Short Term Drought Impact in the Southwest US Using GOES-16 ABI Data

Satellite optical remote sensing has been often used for monitoring broad-region vegetation change, for example, phenology observations and the year-to-year leaf area index (LAI) responses to climate oscillations. However, rapid responses of vegetation to day-to-day weather perturbations are difficult to detect using available optical remote sensing satellites because of the low frequency of the observations. Sun-synchronous optical sensors, such as Moderate Resolution Imaging Spectroradiometer (MODIS) and Advanced Very High Resolution Radiometer (AVHRR), can observe a target area once a day. Daily observations cannot distinguish whether short-term changes in Normalized Differential Vegetation Index (NDVI) are actual LAI change or cloud contamination. NOAA’s GOES satellites make observations every 10 to 15 minutes using the Advanced Baseline Imager (ABI). In this study, we used the Geostationary-NASA Earth Exchange (GeoNEX) L1G Top-of-Atmosphere (TOA) ABI data to detect drought impact on NDVI time series in the Southwest US. We used an empirical method to cancel the BRDF effect of varying solar zenith angle. The ABI was able to detect short term drought impacts as well as an NDVI decrease in the dry season. Increased NDVI right after a rainfall followed by an immediate decrease was observed. These ABI NDVI changes were correlated with the RGB time series from PhenoCam Network data. Results indicated that the ABI can be used for short-term analysis of LAI and can detect small LAI changes caused by drought in an arid area, suggesting the potential for its use in near-real time drought monitoring applications.

ABI↗

Information Foraging and Change Detection for Automated Science Exploration

This paper presents a new algorithm for autonomous on-line exploration in unknown environments. The objective is to free remote scientists from possibly-infeasible extensive preliminary site investigation prior to sending robotic agents. We simulate a common exploration task for an autonomous robot sampling the environment at various locations and compare performance against simpler control strategies. An extension is proposed and evaluated that further permits operation in the presence of environmental variability in which the robot encounters a change in the distribution underlying sampling targets. Experimental results indicate a strong improvement in performance across varied parameter choices for the scenario.

automated exploration↗