Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systems testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Real-Time Inertia Estimation Tool Implementation Based on Probing Signals

As renewable energy penetration increases and the traditional generators retire in power grids, system inertia decreases and exhibits significant daily fluctuations. Furthermore, fast frequency responses (FFRs) provided by the inverter-based resources (IBRs) begin to playa very critical role and bring new challenges to real-time system inertia monitoring due to the difficulties of quantifying its artificial inertia contribution. Thus, necessitating an accurate real-time inertia estimation tool will not only benefit the secure power grid operations, but also provide insights on assessing the artificial inertia contribution from the IBRs. This paper presents a probing-based real-time inertia estimation tool that has been validated through a power-hardware-in-the-Ioop (PHIL) test system using identical hardware battery energy storage system (BESS) and control in an actual power grid. Preliminary results indicate high estimation accuracy of the developed tool and pave the way for the field test and deployment.

inverter-based resources↗

Final report : impacts analysis for cyber attack on electric power systems (national SCADA test bed FY09).

The development continues for Finite State Abstraction (FSA) methods to enable Impacts Analysis (IA) for cyber attack against power grid control systems. Building upon previous work, we successfully demonstrated the addition of Bounded Model Checking (BMC) to the FSA method, which constrains grid conditions to reasonable behavior. The new FSA feature was successfully implemented and tested. FSA is an important part of IA for the power grid, complementing steady-state approaches. It enables the simultaneous evaluation of myriad dynamic trajectories for the system, which in turn facilitates IA for whole ranges of system conditions simultaneously. Given the potentially wide range and subtle nature of potential control system attacks, this is a promising research approach. In this report, we will explain the addition of BMC to the previous FSA work and some testing/simulation upon the implemented code using a two-bus test system. The current FSA approach and code allow the calculation of the acceptability of power grid conditions post-cyber attack (over a given time horizon and for a specific grid topology). Future work will enable analysis spanning various topologies (to account for switching events), as well as an understanding of the cyber attack stimuli that can lead to undesirable grid conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of electron density on the fixed-node errors in Quantum Monte Carlo of atomic systems

We analyze the effect of increasing charge density on the fixed-node errors in diffusion Monte Carlo (FNDMC). We compare FNDMC ground state energies of 4-electron atomic systems with nuclear charge using Hartree–Fock and restricted Configuration Interaction trial wave functions. We perform these calculations for several different values of the nuclear charge, and we analyze the systematic trends of the recovered correlation energies as a function of . For this testing system we demonstrate that the fixed-node error of the Hartree–Fock trial wave functions increases linearly with increasing the nuclear charge.

Chemistry↗

Sustainable extraction of rare earth elements from coal fly ash leachates using a recyclable ionic liquid

The growing demand for rare earth elements (REEs) has prompted interest in their recovery from alternative sources such as coal fly ash (CFA). This study explores the ionic liquid (IL) betainium bis(trifluoromethylsulfonyl)imide, [Hbet][Tf 2 N], for selective extraction of REEs from leachates of a Class C CFA. While previous studies have demonstrated the effectiveness of using [Hbet][Tf 2 N] to extract REEs from different types of CFA in direct ash-IL systems, this study investigates four CFA leachates prepared using HCl, HNO 3 , H 2 SO 4 , and citrate. Extraction experiments were conducted across varying pH levels and with additives such as ascorbic acid and betaine. Among the systems tested, [Hbet][Tf 2 N] achieved REE recoveries of 51% and 47% from the HCl and citrate leachates, respectively, comparable to 49% REE recovery in ash-IL extraction. Co-extraction of bulk elements was significantly reduced in the leachate-IL systems. Optimal REE extraction occurred near pH 11, and addition of ascorbic acid effectively suppressed iron co-extraction without compromising REE recovery. Recycling experiments demonstrated that [Hbet][Tf₂N] retains its performance over five cycles with manageable losses. These results reveal the promise of [Hbet][Tf 2 N] for effectively recovering REEs from leachates of solid wastes, highlighting its applicability as a sustainable strategy for other aqueous REE feedstocks.

chemistry↗

Optimal Droop Setting for Congestion Reduction in a 100% Grid-Forming Inverter-based Power System

he high penetration of inverter-based resources (IBRs) introduces new challenges to power systems due to the complex inverter control. However, IBRs can be configured to maximize their benefits to improve system resilience and reliability. This paper proposes a steady-state optimization model that aims to mitigate transmission congestion in a 100% grid- forming (GFM) IBR-based power system. This goal is achieved by determining the optimal droop settings for the GFM IBRs under different congestion conditions due to renewable energy and load variations. The numerical solution is rigorously verified by a high-fidelity model of the IEEE 39-bus test system with detailed GFM IBR control in the time-domain electromagnetic transient (EMT) simulation tool PSCAD. The numerical solution and simulation results show a significant congestion reduction while meeting all other operating requirements. It is also observed that the numerical solving time is substantially less compared to the EMT simulation time.

Nguyen, Quan H.↗

Smart Particle Collector with Real Time Spectroscopic Analysis

A particle collector breadboard testing system (Racetrack), based on the ACE1.0 particle collector model, was designed and built to study the mechanisms for particle collection and detection. Several parameters were investigated, such as current and voltage of the filament, magnetic fields and supporting electronics. Advanced optical spectroscopic features with data logging capabilities were designed in this project. The advanced features were tested for future incorporation into a new breed of particle collectors. Several experiments conducted with the Racetrack provided a path for a new prototype particle collector “ESP-EV1”. Preliminary results suggest that the new particle collector is an order of magnitude more efficient in collecting material than currently used collector systems. This project also demonstrated the capability to extract nanoparticulates from a sample containing material from 100 nm to 10 micron-sized particulates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The importance of capturing power system operational details in resource adequacy assessments

Traditional methods for assessing the resource adequacy (RA) of a power system are becoming obsolete due to emerging trends such as the increasing deployment of variable renewable energy and storage. Consequently, analysts are recommending that RA be assessed using a Monte Carlo simulation approach that models chronological power system operations over many instances of possible operating conditions. However, this approach is necessarily more complex and computationally demanding, which is an obstacle to real-world implementation. Here, in this study, we investigate which operational details of power systems are important to capture in order to accurately evaluate a system's RA, versus details that add complexity but do not meaningfully affect RA results. To do so, we develop a probabilistic RA assessment framework by adapting an existing production cost model and apply it to a case study based on the IEEE Reliability Test System. Our results indicate that multi-year data, storage dispatch, and transmission limits are key details to incorporate. Accurate RA results can be obtained using non-economic dispatch strategies as long as they are coordinated with detailed operational strategies. We also demonstrate how popular expectation-based RA metrics can mask important differences in the characteristics of loss of load events.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Recovery Act - LADWP Smart Grid Regional Demonstration Program Final Technical Report

LADWP collaborated with its project partners to carry out this demonstration in the designated areas to include two university campuses – the University of California, Los Angeles (UCLA) and the University of Southern California (USC) – surrounding neighborhoods, City of Los Angeles facilities, and LADWP power system test labs. The last project partner, Jet Propulsion Laboratory (JPL) was responsible for the cyber security aspects of the project. The program’s use cases provided insightful information to understand triggers for customers, distributors, and generators to adapt their behavior which aid in reducing system demands and costs, increasing energy efficiency, and increasing grid reliability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

THE SPALLATION NEUTRON SOURCE CRYOMODULE TEST STAND RF SYSTEM

The Spallation Neutron Source (SNS) has recently commissioned a cryomodule test facility for the repair and testing of the super-conducting radio-frequency (SRF) cavities. This facility utilizes the original 402.5/805 MHz Radio Frequency (RF) Klystron Test Stand as its power source along with dual Low Level RF (LLRF) control systems. One control system is based on the standard SNS Linac LLRF controls with a second system for open-loop only control. The system is designed to allow simultaneous testing of devices in the test cave and other devices which can be tested outside of the enclosure. Initial tests have shown good results; some improvements are yet to be implemented.

Crofford, Mark T↗

Combined Effects of Electric Vehicle Charging and Rooftop Solar Integration on Voltage Imbalance in Residential Distribution Networks

Residential electric vehicle (EV) chargers, as single phase loads, contribute to unbalanced voltage drops across phases, while rooftop solar systems, as single phase generators, can exacerbate voltage imbalance by causing unbalanced voltage increases. This paper investigates combined effects of residential EV charging and rooftop solar generation on voltage imbalance in residential distribution grids. The study examines these simultaneous impacts using the IEEE 8500-node test system, enhanced with a secondary network to realistically model the EV chargers and rooftop solar integration. To account for the variability and uncertainty in the EV charging loads and solar generation, a Monte Carlo approach is employed to capture and quantify the simultaneous impact of the EV charging and rooftop solar integration. In this approach, multiple influencing factors are considered, including state-of-charge (SOC), maximum charging power levels, and geographic distribution of chargers. The results provide practical insights for utilities and stakeholders, offering expectations for planning and operating strategies that effectively manage the increasing adoption of EVs and solar power while maintaining grid reliability.

Choi, Jongchan [ORNL] (ORCID:000000025952455X)↗

System Resilience Benefits of Dual-Fuel Capable Generators

The growing dependency on natural gas (NG) for power generation raises challenges for ensuring the resilience of power systems during extreme cold weather. Dual-fuel capable generators that can switch from burning NG to distillate fuel oil during a NG shortage offer one way to alleviate these challenges. In this study, the impacts of gas unavailability on the IEEE 73- bus reliability test system (RTS) with 2019 updated generation mixture are explored. An extension to the standard production cost model formulation of unit commitment and economic dis- patch is proposed to allow representation of dual-fuel capable generators that can switch fuels between NG and distillate oil with a specified oil tank capacity and tank refueling capability. The operation of the system under gas unavailability with 0%, 25%, 50%, 75%, and 100% of combined cycle and combustion turbine generators as dual-fuel capable with a one-day supply of fuel oil are simulated using PLEXOS, a production cost model. The dual-fuel generator performance, unserved energy, and system costs are fully assessed.

duel-fuel generator performance↗

Simulation of Inrush Dynamics for Unbalanced Distribution Systems using Phasor Dynamics

Microgrids are a possible solution to mitigate the extensive interruptions in service to end-use customers caused by abnormal events, such as major natural disasters. Microgrids can be formed by energizing portions of the distribution system to interconnect generator and critical loads. In this scenario, inrush dynamic currents can present a barrier for forming microgrids by preventing the necessary switching operations and/or damaging equipment. Modeling inrush dynamics, through electromagnetic transient tools, presents a challenge when the microgrid represents a large portion of a distribution feeder. This paper uses a phasor dynamics approach to approximate the envelope of inrush dynamics, thus allowing simulations of large systems. The two main contributions of this paper are: a) a new formulation to solve a set of phasor-dynamic differential equations representing an unbalanced distribution system; and b) modeling of transformer saturation in the phasor-dynamics frame. These two contributions allow the in-rush phenomena to be simulated on full size microgrid and/or distribution feeder models. The new formulation and model are implemented in GridLAB-D, and tested on IEEE test systems.

inrush, GridLAB-D, distribution analysis, microgri↗

Parallel Harmony Search Based Distributed Energy Resource Optimization

This paper presents a harmony search based parallel optimization algorithm to minimize voltage deviations in three phase unbalanced electrical distribution systems and to maximize active power outputs of distributed energy resources (DR). The main contribution is to reduce the adverse impacts on voltage profile during a day as photovoltaics (PVs) output or electrical vehicles (EVs) charging changes throughout a day. The IEEE 123- bus distribution test system is modified by adding DRs and EVs under different load profiles. The simulation results show that by using parallel computing techniques, heuristic methods may be used as an alternative optimization tool in electrical power distribution systems operation.

Ceylan, Oguzhan↗

Qualification study of SiPMs on a large scale for the CMVD Experiment

A Cosmic Muon Veto (CMV) detector using extruded plastic scintillators is being designed around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai for the feasibility study of shallow depth underground experiments. The scintillation signals that are produced in the plastic due to muon trajectories are absorbed by wavelength shifting (WLS) fibres. The WLS fibres re-emit photons of longer wavelengths and propagate those to silicon photo-multipliers (SiPMs). The SiPMs detect these photons, producing electronic signals. The CMV detector will use more than 700 scintillators to cover the mini-ICAL detector and will require around 3000 SiPMs. The design goal for the cosmic muon veto efficiency of the CMV is >99.99%. Hence, every SiPM used in the detector needs to be tested and characterised to satisfy the design goal of CMV. A mass testing system was developed for the measurement of gain and choice of the overvoltage ($V_{ov}$) of each SiPMs using an LED driver. The $V_{ov}$ is obtained by studying the noise rate, the gain of the SiPM. This paper describes the experimental setup used to test the SiPMs characteristics along with detailed studies of those characteristics as a function of temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System Resilience Benefits of Dual-Fuel Capable Generators

The growing dependency on natural gas (NG) for power generation raises challenges for ensuring the resilience of power systems during extreme cold weather. Dual-fuel capable generators that can switch from burning NG to distillate fuel oil during an NG shortage over one way to alleviate these challenges. In this study, the impacts of gas unavailability on the IEEE 73-bus reliability test system (RTS) with 2019 updated generation mixture are explored. An extension to the standard production cost model formulation of unit commitment and economic dispatch is proposed to allow the representation of dual-fuel capable generators that can switch fuels between NG and distillate oil with a specified oil tank capacity and tank refueling capability. The operation of the system under gas unavailability with 0%, 25%, 50%, 75%, and 100% of combined cycle and combustion turbine generators as dual-fuel capable with a one-day supply of fuel oil are simulated using PLEXOS, a production cost model. The dual-fuel generator performance, unserved energy, and system costs are fully assessed.

dual-fuel capable generator↗

Operational impacts of high penetration solar power on a real-world distribution feeder

Higher penetration of solar photovoltaic (PV), with their uncontrollable generation variability, imposes various grid stability challenges on distribution system operation. The primary problem is significant voltage rise in the distribution feeder that forces existing voltage control devices such as on-load tap-changers and line voltage regulators to operate more frequently. The consequence is the deterioration of the operating life of the voltage control mechanism. The objective of this paper is to investigate the voltage impact of increased penetration of PV systems on distribution load tap changer operations. Both steady-state and quasi-static power flow analyses have been conducted to assess the impact on load tap changes under different solar PV penetration levels. Two real-world distribution feeder circuits are used as a test system in this study. Simulations are carried out for up to one-year period with 1-minute time step using OpenDSS. A comparison study was performed to investigate potential voltage rise issues in the network by increasing total PV penetration from 0 to 100% in the feeder. Results show significant increase in the total number of tap operations as solar PV penetration increases. Impacts on nodal voltages and feeder net power are also presented.

Dong, Jin↗

Post-Disaster Microgrid Formation for Enhanced Distribution System Resilience

This paper proposes a deep reinforcement learning (DRL) based approach for post-disaster critical load restoration in active distribution systems to form microgrids through network reconfiguration to minimize critical load curtailments. Distribution networks are represented as graph networks, and optimal network configurations with microgrids are obtained by searching for the optimal spanning forest. The constraints to the research question being explored are the radial topology and power balance. Unlike existing analytical and population-based approaches, which necessitate the repetition of entire analyses and computation for each outage scenario to find the optimal spanning forest, the proposed approach, once properly trained, can quickly determine the optimal, or near-optimal, spanning forest even when outage scenarios change. When multiple lines fail in the system, the proposed approach forms microgrids with distributed energy resources in active distribution systems to reduce critical load curtailment. The proposed DRL-based model learns the action-value function using the REINFORCE algorithm, which is a model-free reinforcement learning technique based on stochastic policy gradients. A case study was conducted on a 33-node distribution test system, demonstrating the effectiveness of the proposed approach for post-disaster critical load restoration.

active distribution systems↗

A Hierarchical VLSM-Based Demand Response Strategy for Coordinative Voltage Control between Transmission and Distribution Systems

This paper presents a two-stage hierarchical voltage-load sensitivity matrix (VLSM)-based demand response (DR) algorithm for regulating the voltage at distribution feeders while fulfilling the transmission system DR requests. This allows distributed energy resources be aggregated to provide transmission-level services without causing operational issues in the distribution grids. At the beginning of each operation interval, a transmission system controller will issue DR commands to distribution system controllers. In the first stage, the distribution system controller uses a VLSM-based dispatch algorithm to dispatch the available DR resources on the distribution feeder with an objective to minimize the total voltage deviations at the lowest cost. Then, power flow studies are conducted assuming that the DR commands have been executed. If voltage violations are detected, a second-stage VLSM-based DR dispatch will be performed to remove those violations. After that, the upper and lower DR limits calculated for the next operation interval are sent back to the transmission system controller so the transmission optimization algorithm can use them as operational constraints to make subsequent decisions. The DR resources include smart photovoltaic (PV) inverters that can curtail real power and provide reactive power support, controllable loads and capacitor banks. In conclusion, the IEEE 123-bus test system with 5-minute PV and load data is used to evaluate the performance of the algorithm. In conclusion, simulation results show that the proposed algorithm can fulfill the transmission-level DR requests while maintaining the voltage in the distribution system within limits.

24 POWER TRANSMISSION AND DISTRIBUTION↗