Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Deciphering Photoinduced Catalytic Reaction Mechanisms in Natural and Artificial Photosynthetic Systems on Multiple Temporal and Spatial Scales Using X-ray Probes

Utilization of renewable energies for catalytically generating value-added chemicals is highly desirable in this era of rising energy demands and climate change impacts. Artificial photosynthetic systems or photocatalysts utilize light to convert abundant CO 2 , H 2 O, and O 2 to fuels, such as carbohydrates and hydrogen, thus converting light energy to storable chemical resources. Here, the emergence of intense X-ray pulses from synchrotrons, ultrafast X-ray pulses from X-ray free electron lasers, and table-top laser-driven sources over the past decades opens new frontiers in deciphering photoinduced catalytic reaction mechanisms on the multiple temporal and spatial scales. Operando X-ray spectroscopic methods offer a new set of electronic transitions in probing the oxidation states, coordinating geometry, and spin states of the metal catalytic center and photosensitizers with unprecedented energy and time resolution. Operando X-ray scattering methods enable previously elusive reaction steps to be characterized on different length scales and time scales. The methodological progress and their application examples collected in this review will offer a glimpse into the accomplishments and current state in deciphering reaction mechanisms for both natural and synthetic systems. Looking forward, there are still many challenges and opportunities at the frontier of catalytic research that will require further advancement of the characterization techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The approximate second order coupled-cluster method based on a size-consistent Brillouin–Wigner partitioning

We present a variant of the approximate second order coupled-cluster method (CC2) with a two-parameter size-consistent Brillouin–Wigner (BW-s) partitioning instead of a Møller–Plesset (MP) partitioning for the unperturbed Hamiltonian, which we refer to as BWs-CC2. The computational complexity of this model scales identically to CC2 with molecular size. Conventional CC2 and its regularized BWs-CC2 variants, as well as conventional MP2 and two of its regularized BW-s2 variants, were assessed on a 535 element database spanning thermochemistry, non-covalent interactions, barrier heights, and isomerization energies. To ensure a well-defined model chemistry, the assessment was performed using internally stable spin-polarized Hartree–Fock (HF) orbitals in the finite aug-cc-pVQZ basis without counterpoise corrections. As a result of using stable orbitals, contrary to conventional wisdom, we find that CC2 substantially outperforms MP2 on molecules with significantly spin contaminated reference orbitals without a significant increase in error on systems with a spin-pure reference, showing the value of its single substitutions. While no single choice of regularization parameters can be optimal for all datasets, we find that BWs-CC2 generally outperforms both CC2 and BW-s2 with a single judicious parameter choice. Additional tests on dipole moments and bond lengths of diatomics provide further support for the utility of this choice. Furthermore, the main outliers and poorest performing cases are associated with large amounts of spin-contamination in the HF reference, which is indicative of systems with either strong correlation or extensive artificial symmetry breaking. Overall, these findings argue that the perception of the quality of the CC2 ground state should be reevaluated and that it can be further improved upon by the soundly based BWs-CC2 variant with the recommended parameter choice.

Correlation energy↗

Developing socially and economically generative, resilient PV-energy systems for low- and moderate-income communities: Applications for Puerto Rico (Final Technical Report)

The nexus of energy and poverty is one of the most significant long-term challenges facing the energy and electricity sectors, with negative feedback loops between energy-related costs, risks, and insecurities, on the one hand, and diverse other social and economic insecurities, on the other, helping to undermine health, wellbeing, and resilience in low- and moderate-income communities around the US and the world (Biswas et al. 2022). The transition of energy systems to clean energy alternatives offers a potential opportunity to redesign future energy arrangements in ways that, instead, create beneficial social value for communities, reverses the energy-poverty nexus, and enhances community wellbeing (Biswas et al. 2020; Miller et al. 2018). The promise of clean energy transitions to address the energy-poverty nexus is especially significant when designed using principles of just energy transitions. To leverage just clean energy transitions to accomplish a reversal of the energy-poverty nexus requires improvement in three capabilities: (1) Understanding and mapping the community-scale dynamics and variability of the energy-poverty nexus, which vary considerably from community to community; (2) Evaluating the technical, social, and economic potential for different clean energy system designs to deliver social value to specific communities; and (3) Working collaboratively with communities to imagine and design clean energy systems solutions that meet their needs, fit their capabilities and contexts, and deliver multiple forms of community-desired social value/benefits that help reverse key facets of the energy-poverty nexus. This project developed a portfolio of novel tools, methodological approaches, and collaborative partnerships with four communities in Puerto Rico that further the objective of building these three capabilities.

14 SOLAR ENERGY↗

CATMoS: Collaborative Acute Toxicity Modeling Suite

Background: Humans are exposed to tens of thousands of chemical substances that need to be assessed for their potential toxicity. Acute systemic toxicity testing serves as the basis for regulatory hazard classification, labeling, and risk management. However, it is cost- and time-prohibitive to evaluate all new and existing chemicals using traditional rodent acute toxicity tests. In silico models built using existing data facilitate rapid acute toxicity predictions without using animals. Objectives: The U.S. Interagency Coordinating Committee on the Validation of Alternative Methods Acute Toxicity Workgroup organized an international collaboration to develop in silico models for predicting acute oral toxicity based on five different endpoints: LD50 value, U.S. Environmental Protection Agency hazard categories, Globally Harmonized System for Classification and Labelling hazard categories, very toxic chemicals (LD50 =50 mg/kg), and non-toxic chemicals (LD50 >2000 mg/kg). Methods: An acute oral toxicity data inventory for 11,992 chemicals was compiled, split into training and evaluation sets, and made available to 35 participating international research groups that submitted a total of 139 predictive models. Predictions that fell within the applicability domains of the submitted models were evaluated using external validation sets. These were then combined into consensus models to leverage strengths of individual approaches. Results: The resulting consensus predictions, which leverage the collective strengths of each individual model, form the Collaborative Acute Toxicity Modeling Suite (CATMoS). CATMoS demonstrated high performance in terms of accuracy and robustness when compared to in vivo results. Discussion: CATMoS is being evaluated by regulatory agencies for its utility and applicability as a potential replacement for in vivo rat acute oral toxicity studies. CATMoS predictions for over 800,000 chemicals have been made available via the NTP’s Integrated Chemical Environment. The models are also implemented in a free, standalone open-source tool, OPERA, which allows predictions of new and untested chemicals to be made.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Development of High-Temperature Emissivity Measurement Capabilities for Molten Salts at PNNL

In this study, an emissivity measurement system for a liquid molten salt was developed on the bases on the Stefan Boltzmann Law. A prototype device operating in ambient atmosphere was constructed an initial result compared well with available literature. The diffuse emissivity of NaCl-KCl system (NaCl, 51mol% NaCl – 49mol% KCl and KCl) was measured from 550 to 850 °C at a wavelength of 1.3 µm. The system appears to be relatively invariant with composition but a clear trend of decreasing emissivity values from ~0.9 at 550 °C to 0.75 at 850 °C was observed. A schematic for an enclosed system for inert atmosphere and actinide salts was drafted. Several of the components for fabrication of this device, improved laser system, furnace, nickel for capsule construction, have been purchased and are ready for assembly. The new laser system will have an improved measurement range of 275-1000 °C. The clam shell furnace has a maximum temperature of 1200 °C and will support the hermetically sealed inert encapsulation vessels. Nickel plate and tubing will create a relatively corrosion resistance capsule for testing that can withstand temperature up to 1000 °C. Emissivity measurements are important for a larger effort to understand radiative heat transfer within molten salts at elevated temperatures (600-1000 °C). Literature review of optical salt properties and radiative heat transfer models indicated that systems within elevated temperature regimes could see upwards of 20% or more of their total heat transferred through photonic mechanisms. Ultimately, future work will measure the total thermal conductivity and break down the molecular and radiative portions. Thermal conductivity, along with other thermal properties of molten salts, both coolant and fuel, are fundamental to modeling and simulations that support MSR design. The results presented here and ongoing work at PNNL will be useful in selecting optimal salt compositions, designing reactor systems, and optimizing heat transfer within a MSR power plant.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Adapting Existing Energy Planning, Simulation, and Operational Models for Resilience Analysis

Resilience is a topic receiving much attention in relation to energy systems, with particular attention being paid to the supply of electricity. As a result, research communities have proposed a plethora of candidate indicators and metrics for resilience, most of which remain immature at different scales and segments within the energy system. Given the complexity of resilience analyses and mitigation strategies, there is limited value in attempting to identify a single resilience metric, as no one metric can quantify resilience or its associated value for all stakeholders. Instead, a necessary focus of the research community should lie in implementing, testing, and validating resilience metrics and analysis approaches in energy sector models, which will be invaluable for informing resilience planning and investment decisions. Recognizing that implementing, testing, and validating resilience metrics are challenges that need to be addressed, the National Renewable Energy Laboratory (NREL) dedicated staff and time to researching how to effectively integrate resilience considerations into energy sector models and tools, as part of the Laboratory Directed Research and Development (LDRD) program. The overarching goal of the effort was to evaluate the data needs, methodologies, and outcomes - including consequences and/or changes in investment or operational decisions due to avoided consequences - based on resilience analysis in a range of existing tools. In particular, we selected five models originally built at NREL to explore non-resilience energy research questions to implement and exercise resilience metrics and analysis approaches.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Empirical validation of building energy simulation model input parameter for multizone commercial building during the cooling season

This paper presents a critical advancement in Building Energy Modeling (BEM) through an empirical validation approach using a high-quality dataset from a multizone commercial office building in Oak Ridge, TN, USA. BEM is widely utilized in diverse construction applications, but its effectiveness relies on the accuracy of its predictions. The study focuses on empirical validation of input parameters in BEM, including building envelope data, infiltration modeling, and rooftop unit system performance curves. The validation of simulation input parameters leads to substantial improvements in the accuracy of simulation results. Notable both NMBE and cv (RMSE) values are reduced by 0.5 % for indoor air temperature and 17 % for indoor air relative humidity compared to the previous model. At the system level, both NMBE and cv (RMSE) values are reduced by 2 % for fan energy consumption and 4 % for cooling energy consumption, compared to the previous model. A literature review highlights a significant gap in empirical validation studies, which predominantly concentrate on either component-level or whole building validation. Furthermore, many studies employ simplified setups that may not faithfully represent the complexities of multizone commercial buildings. This paper distinguishes itself by emphasizing the critical importance of component-level input parameter validation. It underlines the need to validate data related to building envelope components and HVAC system performance curves, resulting in more accurate simulation outcomes. In conclusion, the utilization of actual multizone commercial building data enhances the study's practical relevance. In summary, this research underscores the pivotal role of input parameter validation in enhancing the accuracy and reliability of BEM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identification of Intraday False Data Injection Attack on DER Dispatch Signals

The urgent need for the decarbonization of power grids has accelerated the integration of renewable energy. Concurrently, increasing distributed energy resources (DER) and advanced metering infrastructure (AMI) have transformed the power grids into a more sophisticated cyber-physical system with numerous communication devices. While these transitions provide economic and environmental value, they also impose increased risk of cyber attacks and operation al challenges. This paper investigates the vulnerabilit y of the power grids with high renewable penetration against an intraday false data injection (FDI) attack on DER dispatch signals and proposes a kernel support vector regression (SVR) based detection model as a countermeasure. The intraday FDI attack scenario and the detection model are demonstrated in a numerical experiment using the HCE 187-bus test system.

Kim, Jip↗

An optimization framework for the network design of advanced district thermal energy systems

In this work, a topology optimization framework for district thermal energy systems is presented. The framework seeks to address the questions, for a given district, "What is the best subset of buildings to connect to a district thermal energy system, and by what network should they be connected, to minimize life cycle cost?" A particle swarm optimization approach is validated to address the selection of the subset of buildings, and a graph theory-based heuristic is validated for selection of the network topology for any candidate subset of buildings. The framework is applied to a prototypical urban district for illustrative purposes. Additionally, modeling of prototypical districts revealed reductions in source energy use intensity for heating and cooling of 21-25% through the use of advanced district energy systems relative to code-compliant, building level systems. The framework identifies solutions with life cycle cost values 14% to 72% lower than that of base case scenarios based on conventional design approaches, depending on the base case scenario selected. Analysis of the search space indicates that topology optimization facilitates reductions in life cycle cost, source energy use intensity, and carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Valuing Maintenance Strategies for Fusion Plants as Part of a Future Electricity Grid

Scheduled maintenance is likely to be lengthy and therefore consequential for the economics of fusion power plants. The maintenance strategy that maximizes the economic value of a plant depends on internal factors such as the cost and durability of the replaceable components, the frequency and duration of the maintenance blocks, and the external factors of the electricity system in which the plant operates. Here, this paper examines the value of fusion power plants with various maintenance properties in a decarbonized United States Eastern Interconnection circa 2050. Seasonal variations in electricity supply and demand mean that certain times of year, particularly spring to early summer, are best for scheduled maintenance. Seasonality has two important consequences. First, the value of a plant can be 15% higher than what one would naively expect if value were directly proportional to its availability. Second, in some cases, replacing fractions of a component in shorter maintenance blocks spread over multiple years is better than replacing it all at once during a longer outage, even through the overall availability of the plant is lower in the former scenario.

power plant, maintenance, seasonality, electricity↗

A Reinforcement Learning Approach to Augment Conventional PID Control in Nuclear Power Plant Transient Operation

The ability of nuclear reactors to operate their power conversion cycles more flexibly will enhance their value to energy grids with variable pricing. Current nuclear control systems are typically classical controllers that are often based on proportional-integral-derivative (PID) control. This paper presents a method of augmenting the existing PID control for difficult transient operations in nuclear power plants using a reinforcement learning–derived feedforward signal applied in real time. The agents, which are trained on a test thermal load-following problem, are designed to improve steam generator outlet temperature control for a range of fast load-following scenarios covering ramp rates from 9%/min to 15%/min. Several reinforcement learning algorithms were initially investigated for the training of the feedforward agents with deep Q-learning (DQN) and proximal policy optimization (PPO) networks, which were found to be the most promising. The DQN controllers utilize discrete actions, giving them a better disturbance rejection at steady state but inconsistent response to initial temperature deviations. In contrast, PPO-trained agents, which take continuous actions except for a dead zone around zero, were shown to have the best combination of high disturbance rejection at steady state and good tracking of the desired temperature value. The ability of the PPO agent was also examined, with the average time of decision making found to be on the order of 1 ms. The fault properties of the controller under the loss of the reinforcement learning agent feedforward signal were also examined. The controller showed strong performance in situations of “no-signal” faults. but was less good at handling “stuck-at” faults, where the feedforward signal remains at a set value. In both cases, however, the PID was able to successfully maintain stability, eventually returning the system to a steady state. It is hoped that this work will allow for the proposed control architecture to be examined for more difficult control problems such that it may eventually be used to adapt existing nuclear plants for more aggressive load-following on grids of the future.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Specifying Calibration of Environmental Sensors

The emergence of the Internet of Things is resulting in an increased ability of devices and systems to share data and is generating increasing interest in integrating sensors into a variety of devices deployed in the built environment. The value of such data is a function of how the data can be used. Data-producing devices and systems that enable valuable use-cases in turn can be seen as more valuable. Lighting systems are particularly interesting platforms for integrated sensors. Both indoor and outdoor lighting devices are becoming more connected, and their location is often ideally suited for hosting environmental sensors that can characterize the properties of indoor or outdoor spaces in ways that support a wide variety of use cases, from improving air quality to supporting fault diagnostics and prediction. The value of environmental-sensor-driven use-cases and the lighting systems that house them is dependent to some degree on sensor accuracy. Environmental sensors utilize a wide variety of sensing techniques or technologies and have varying accuracy. More-accurate, laboratory-grade products or reference standards are often used to characterize, refine, calibrate, adjust, and monitor devices that are deployed, or are intended to be deployed, in physical spaces of interest. Sensors or reference standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user and use-case requirements. This paper provides guidance for evaluating the performance of environmental sensors so as to ensure that they meet user or use-case needs. It describes best practices that have been developed for a) calibrating sensors to ensure some known level of accuracy, and b) determining whether calibration-laboratory accreditation meets user or use-case needs. Excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently have sensors calibrated or who have new or changing needs for sensor calibration, rationale is provided for why a specification might be used to request calibration services that meet specific needs. Commercially available calibration-service providers that are accredited for environmental-sensor calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of environmental-sensor test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

42 ENGINEERING↗

Bias control for a memory device

Methods, systems, and devices for bias control for a memory device are described. A memory system may store indication of whether data is coherent. In some examples, the indication may be stored as metadata, where a first value indicates that the data is not coherent and a second value or a third value indicate that the data is coherent. When a processing unit or other component of the memory system processes a command to access data, the memory system may operate according to a device bias mode when the indication is the first value, and according to a host bias mode when the indication is the second value or the third value.

97 MATHEMATICS AND COMPUTING↗

Bias control for a memory device

Methods, systems, and devices for bias control for a memory device are described. A memory system may store indication of whether data is coherent. In some examples, the indication may be stored as metadata, where a first value indicates that the data is not coherent and a second value or a third value indicate that the data is coherent. When a processing unit or other component of the memory system processes a command to access data, the memory system may operate according to a device bias mode when the indication is the first value, and according to a host bias mode when the indication is the second value or the third value.

Walker, Dean↗

Reactor System Facility Modification to Detect Compromised Human Machine Interfaces

This study focuses on a multi-layered Industrial Control System (ICS)/Operational Technology (OT) security architecture to aid in the discovery and mitigation of compromised Human Machine Interface (HMI)/Instrumentation & Control (I&C) based systems for modifying a prototypical reactor condition test facility called the Flowing Autoclave System (FAS) at Idaho National Laboratory (INL). This is achieved through a three-layered combination of network security solutions, hash-based algorithms, and blockchain technologies. Hash algorithms are mathematical functions used to generate a predetermined set of fixed-length values. They are widely used in computer security to verify the integrity of system information and data, both on a local network and the wider internet. Even small amounts of unauthorized system modification will cause the hash algorithm to output a set of characters that deviate significantly from its original value. Assisting secure hash functions, blockchain technology is a secure and distributed technology used to provide an immutable set of records replicated on all devices within a decentralized network. Blockchain offers a cost-effective solution to detect system compromise by providing a traceable breadcrumb trail of all network activity and data modification happening on a system. If both are used in conjunction with network monitoring tools, the integration of this three-pronged approach can become an asset in detecting suspected system compromises before any real damage can occur.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

County-level assessment of behind-the-meter solar and storage to mitigate long duration power interruptions for residential customers

Customer concerns over electric system resilience could drive early adoption of behind-the-meter solar-plus-storage (BTM PVESS), especially as wildfire, hurricane, and other climate-driven risks to electric grids become more pronounced. However, the resilience benefits of BTM PVESS are poorly understood, especially for residential customers, owing to lack of data and methodological challenges, making it difficult to forecast adoption trends. In this paper, we develop a methodology to model the performance of BTM PVESS in providing backup power across a wide range of customer types, geography / climate conditions, and long duration power interruption scenarios, considering both whole-building backup and backup of specific critical loads. We combine novel, disaggregated end-use load profiles across the continental United States with temporally and geospatially aligned solar generation estimates. We then implement a PVESS dispatch algorithm to calculate the amount of load served during interruptions. We find that PVESS with 10 kWh of storage can meet a limited set of critical loads in most United States counties during any month of the year, though this capability drops to meeting only 86% of critical load, averaged across all counties and months, when heating and cooling are considered critical. Backup performance is lowest in winter months where electric heat is common (southeast and northwest U.S.) and in summer months in places with large cooling loads (southwest and southeast U.S.). Winter backup performance varies by roughly 20% depending on infiltration rates, while summer performance varies by close to 15% depending on the efficiency of the central air-conditioning system. Differences in temperature set-points in Harris County correspond to a 40% range in winter backup performance and a 20% range in summer performance. Economic calculations show that a customer’s resilience value of PVESS must be high to motivate adoption of these systems.

14 SOLAR ENERGY↗