Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

Quantifying Uncertainty of Landing and Takeoff Noise for Commercial Supersonic Aircraft

Of the many challenges faced by manufacturers attempting to offer supersonic travel to the public, the uncertainty in predicting the noise of these aircraft in airport operations has an immediate impact. No noise regulation exists in FAA or ICAO for certifying such aircraft, as these organization require solid data, usually from existing aircraft. Manufacturers are taking large risks to design a vehicle not knowing whether it will be allowed to fly. A partial solution to this conundrum is to use physics-based simulations to provide the “data” used to calibrate system-level prediction methods, carefully documenting the uncertainty of the method for application to supersonic aircraft. A close look at the accuracy of empirical prediction methods points to areas where improvements need to be made if noise studies of supersonic aircraft are to be useful. As NASA embarks on a focused research program to improve predictions of noise from the noise-dominant propulsion noise of commercial supersonic aircraft, this paper documents the work done to baseline the uncertainties found in today’s noise prediction methods. A relatively simplistic method was developed, summarizing the error of the empirical methods on a component basis and following their impact on the total aircraft during landing and takeoff operations using Monte Carlo analysis. By this method it is found that current empirical noise prediction methods have an uncertainty of 1.5 EPNdB cumulative for propulsion noise of a representative conventional subsonic passenger aircraft. When applied to likely near-term supersonic commercial aircraft, the uncertainty is 7.6 EPNdB cumulative, a difference that must be reduced if the prediction methods are to guide decision makers.

Airport noise↗

Ozone Monitoring Instrument (OMI) collection 4: establishing a 17-year-long series of detrended level-1b data

The Ozone Monitoring Instrument (OMI) was launched on 15 July 2004, with an expected mission lifetime of 5 years. After more than 17 years in orbit the instrument is still functioning satisfactorily and in principle can continue doing so until the expected decommissioning of its platform Aura in 2025. In order to continue the datasets acquired by OMI and the Microwave Limb Sounder, the mission was extended up to at least 2023. Actions have been taken to ensure the proper functioning of the OMI operations, the data processing, and the calibration monitoring system until the eventual end of the mission. For the data processing a new level-0 (L0) to level-1b (L1b) data processor was built based on the recent developments for the TROPOspheric Monitoring Instrument (TROPOMI). With corrections for the degradation of the instrument now included, it is feasible to generate a new data collection to supersede the current collection-3 data products and reprocess the data of the entire mission up to now. This paper describes the differences between the collection-3 and collection-4 data. It will be shown that the collection-4 L1b data comprise a clear improvement with respect to the previous collections. By correcting for the gentle optical and electronic aging that has occurred over the past 17 years, OMI’s ability to make trend-quality ozone measurements has further improved.

UV↗

Dust Ejecta RADAR Technology (DERT): A Millimeter Wave Doppler Radar to Measure Plume Surface Interaction Ejecta Velocities

A novel method to measure the velocity of ejecta generated by the impingement of rocket plumes on a lunar or planetary surface is presented. Dust Ejecta RADAR Technology (DERT), is a Millimeter Wave Doppler Radar sensor that provides a unique dataset based on direct measurements of ejecta particle velocities during plume-surface interactions, which will help inform risk assessments associated with impacts by high-speed ejecta particles. DERT has measured velocities of a pendulum (~1 m/s), a rotating strip (60 m/s), projected regolith simulant BP-1 (~250 m/s) and rifle rounds (~820 m/s). Signal-to-noise ratios of up to 60 dB with regolith simulant BP-1 have been demonstrated with a CW 94 GHz unit. Data collected from DERT will inform the development of high-fidelity computational models of plume-surface interaction effects and will help address NASA Strategic Knowledge Gaps related to characterizing entry, descent and landing effects, and the risks associated with high-speed ejecta on the lander and lunar surface assets. Recent efforts to develop DERT as a flight instrument are presented as well as the development of a Lunar Regolith Ejecta Simulator (LuRES) system to calibrate DERT.

PSI↗

A Preliminary Assessment of Step Effects on the BOLT Geometry in Mach 6 Flow

An infrared thermography measurement technique has been installed in the Langley Aerothermodynamic Laboratory. The system is calibrated for use with commercially available thermoplastics and ceramic materials, and to the surface temperature ranges when exposed to the facility hypersonic flow. Herein an uncertainty quantification is performed, revealing 5% surface temperature and 20% heat transfer uncertainty bands to two-sigma confidence. As a first application of the test measurement technique, an investigation was conducted to explore the correlation between the height of forward facing (FF) and rearward facing (RF) two-dimensional steps, free stream Reynolds number, and the onset of boundary layer transition from laminar to turbulent in Mach 6 flow on a 50% scale Boundary Layer Transition (BOLT) flight test vehicle geometry. Computational predictions were generated to identify potential x/L locations of transition onset for various flow conditions with a smooth outer mold line geometry and are compared to experimental results. The BOLT Step Test was conducted in the NASA Langley Aerothermodynamic Laboratory 20-inch Mach 6 wind tunnel at Reynolds numbers between 1.4 and 11.3 million conditions for various step heights. Data were collected using a developmental infrared thermography test technique and reduced to heat transfer for comparison with CFD solutions. This is a preliminary assessment of the developmental infrared thermography test technique used to acquire and reduce the experimental data. insight into the ongoing comparative analysis of the effects of FF and RF steps on boundary layer transition for the BOLT geometry in Mach 6 flow.

BOLT↗

A Preliminary Assessment of Step Effects on the BOLT Geometry in Mach 6 Flow

An infrared thermography measurement technique has been installed in the Langley Aerothermodynamic Laboratory. The system is calibrated for use with commercially available thermoplastics and ceramic materials, and to the surface temperature ranges when exposed to the facility hypersonic flow. Herein an uncertainty quantification is performed, revealing 5% surface temperature and 20% heat transfer uncertainty bands to two-sigma confidence. As a first application of the test measurement technique, an investigation was conducted to explore the correlation between the height of forward facing (FF) and rearward facing (RF) two-dimensional steps, free stream Reynolds number, and the onset of boundary layer transition from laminar to turbulent in Mach 6 flow on a 50% scale Boundary Layer Transition (BOLT) flight test vehicle geometry. Computational predictions were generated to identify potential x/L locations of transition onset for various flow conditions with a smooth outer mold line geometry and are compared to experimental results. The BOLT Step Test was conducted in the NASA Langley Aerothermodynamic Laboratory 20-inch Mach 6 wind tunnel at Reynolds numbers between 1.4 and 11.3 million conditions for various step heights. Data were collected using a developmental infrared thermography test technique and reduced to heat transfer for comparison with CFD solutions. This is a preliminary assessment of the developmental infrared thermography test technique used to acquire and reduce the experimental data. insight into the ongoing comparative analysis of the effects of FF and RF steps on boundary layer transition for the BOLT geometry in Mach 6 flow.

BOLT↗

Life After Launch: A Snapshot of the First 6 Months of NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) Mission

The NASA Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission launched from Kennedy Space Center in the early morning of February 8, 2024. Just 63 days later, data from NASA’s newest Earth-observing satellite became available to the public. These data will extend and improve upon NASA’s 20+ years of global satellite observation of our living oceans, atmospheric aerosols, and cloud and initiate an advanced set of climate-relevant data records. Ultimately, PACE is the first mission to provide daily, global measurements that will enable prediction of the “boom-bust” cycle of fisheries, the appearance of harmful algae, and other factors that affect commercial and recreational industries. PACE also observes clouds and tiny airborne particles known as aerosols that influence air quality and absorb and reflect sunlight, thus warming and cooling the atmosphere. In the months since launch and initial data release, the PACE Project pursued instrument temporal and system vicarious calibrations, executed cross-instrument comparisons, conducted performance assessments, explored synergies with other missions, and released advanced science data products. In parallel, the PACE Validation Science Team left for the field and the Post-launch Airborne eXperiment (PACE-PAX) prepared for its mission. And, most importantly, preliminary science results were realized. Here, we present a snapshot of these activities and their impacts and outcomes, encompassing the first half year of the PACE mission.

PACE↗

DFT Calculation of Thermal Expansion within Debye-Grüneisen Framework Made Simple and Accurate

The density functional theory (DFT) based Debye-Grüneisen approach is a computational method used to calculate the thermodynamic properties of materials by relating the volume dependence of the Debye frequency to the Grüneisen parameter. In this study, we propose a new model to describe the volume dependence of the Grüneisen parameter. This model offers a simple yet accurate approach to predict the thermal expansion of materials within the framework of the Debye-Grüneisen theory. Specifically, for pure elements or species used as a reference system, we calibrated the parameters to reproduce the experimental coefficient of thermal expansion, heat capacity, and entropy. For compounds with arbitrary compositions, the parameters are determined by taking the arithmetic or geometric average of those obtained from the pure elements or species based on their composition. We then compared the model prediction with experiments. This allowed for a comprehensive characterization of the thermal expansion behavior of various materials.

Wang, Yi↗

Calibration and Measurement techniques in the LLRF systems of the Fermilab PIP-II Linac

he PIP-II Accelerator is an 800 MeV superconducting Linac in the injection chain of the Fermilab accelerator complex. The LLRF systems are a based on two different hardware platforms controlling a variety of cavity types and resonance control systems including temperature, pneumatic and piezzo tuners. The various calibrations required prior to beam operation include, signal power, gradient, amplifier characterization, cavity Q measurement and detune constants. Measurements such as piezzo capacitance, cavity piezo transfer function help in determining tuner health and in devising microphonics control strategies. These measurement and calibration methods of the PIP-II LLRF system are discussed here.

Varghese, P.↗

Development and implementation of the NASA Metrology and Information System

The NASA Metrology Information System (NMIS) was developed as a subsystem of the NASA Equipment Management System (NEMS) to provide a standardized technique in managing the calibration programs of its field Centers and facilities. The NMIS is a computerized data-base system providing: automatic instrument calibration recall and control, historical data including calibration and repair labor and parts costs, incoming instrument performance condition; instrument data including description, manufacturer, model and serial number, and instrument user name location. NMIS automatically provides 28 standardized calibration system performance reports on a user selected schedule. An ad hoc report generation capability is also provided. A standardized form, the Metrology Control Document, was developed for use as a calibration work order and data input document. System implementation plan is presented.

German, Earl S.↗

Method and apparatus for calibrating a tiled display

A display system that can be calibrated and re-calibrated with a minimal amount of manual intervention. To accomplish this, one or more cameras are provided to capture an image of the display screen. The resulting captured image is processed to identify any non-desirable characteristics, including visible artifacts such as seams, bands, rings, etc. Once the non-desirable characteristics are identified, an appropriate transformation function is determined. The transformation function is used to pre-warp the input video signal that is provided to the display such that the non-desirable characteristics are reduced or eliminated from the display. The transformation function preferably compensates for spatial non-uniformity, color non-uniformity, luminance non-uniformity, and other visible artifacts.

Johnson, Michael J.↗

Aquarius's Instrument Science Data System (ISDS) Automated to Acquire, Process, Trend Data and Produce Radiometric System Assessment Reports

The Aquarius Radiometer, a subsystem of the Aquarius Instrument required a data acquisition ground system to support calibration and radiometer performance assessment. To support calibration and compose performance assessments, we developed an automated system which uploaded raw data to a ftp server and saved raw and processed data to a database. This paper details the overall functionalities of the Aquarius Instrument Science Data System (ISDS) and the individual electrical ground support equipment (EGSE) which produced data files that were infused into the ISDS. Real time EGSEs include an ICDS Simulator, Calibration GSE, Labview controlled power supply, and a chamber data acquisition system. ICDS Simulator serves as a test conductor primary workstation, collecting radiometer housekeeping (HK) and science data and passing commands and HK telemetry collection request to the radiometer. Calibration GSE (Radiometer Active Test Source) provides source choice from multiple targets for the radiometer external calibration. Power Supply GSE, controlled by labview, provides real time voltage and current monitoring of the radiometer. And finally the chamber data acquisition system produces data reflecting chamber vacuum pressure, thermistor temperatures, AVG and watts. Each GSE system produce text based data files every two to six minutes and automatically copies the data files to the Central Archiver PC. The Archiver PC stores the data files, schedules automated uploads of these files to an external FTP server, and accepts request to copy all data files to the ISDS for offline data processing and analysis. Aquarius Radiometer ISDS contains PHP and MATLab programs to parse, process and save all data to a MySQL database. Analysis tools (MATLab programs) in the ISDS system are capable of displaying radiometer science, telemetry and auxiliary data in near real time as well as performing data analysis and producing automated performance assessment reports of the Aquarius Radiometer.

Source record↗

Calibration technique of wall shear stress sensors using oscillating plate

Disclosed are a system and methods for calibrating wall shear stress sensors. The system includes an oscillating plate coupled to an actuator and mounted on a rolling elements, and one or more sensors coupled to a height adjusting device. The system can further comprise a height control rod coupled to a height control base and a sensor holder configured to house the one or more sensors and supported on a connector, the connector configured to be rotatably disposed about the height control rod. The system can be calibrated by causing the actuator to oscillate the oscillating plate at a frequency, sensing, using the one or more sensors, shear stress at a wall, the shear stress at the wall being associated with a velocity field, and determining a theoretical wall shear stress based on fluid properties, the frequency, and the height of the one or more sensors above the oscillating plate.

Freidkes, Brett R.↗

Calibration improvements to electronically scanned pressure systems and preliminary statistical assessment

Orifice-to-orifice inconsistencies in data acquired with an electronically-scanned pressure system at the beginning of a wind tunnel experiment forced modifications to the standard, instrument calibration procedures. These modifications included a large increase in the number of calibration points which would allow a critical examination of the calibration curve-fit process, and a subsequent post-test reduction of the pressure data. Evaluation of these data has resulted in an improved functional representation of the pressure-voltage signature for electronically-scanned pressures sensors, which can reduce the errors due to calibration curve fit to under 0.10 percent of reading compared to the manufacturer specified 0.10 percent of full scale. Application of the improved calibration function allows a more rational selection of the calibration set-point pressures. These pressures should be adjusted to achieve a voltage output which matches the physical shape of the pressure-voltage signature of the sensor. This process is conducted in lieu of the more traditional approach where a calibration pressure is specified and the resulting sensor voltage is recorded. The fifteen calibrations acquired over the two-week duration of the wind tunnel test were further used to perform a preliminary, statistical assessment of the variation in the calibration process. The results allowed the estimation of the bias uncertainty for a single instrument calibration; and, they form the precursor for more extensive and more controlled studies in the laboratory.

Everhart, Joel L.↗

Calibration of NASA Turbulent Air Motion Measurement System

A turbulent air motion measurement system (TAMMS) was integrated onboard the Lockheed 188 Electra airplane (designated NASA 429) based at the Wallops Flight Facility in support of the NASA role in global tropospheric research. The system provides air motion and turbulence measurements from an airborne platform which is capable of sampling tropospheric and planetary boundary-layer conditions. TAMMS consists of a gust probe with free-rotating vanes mounted on a 3.7-m epoxy-graphite composite nose boom, a high-resolution inertial navigation system (INS), and data acquisition system. A variation of the tower flyby method augmented with radar tracking was implemented for the calibration of static pressure position error and air temperature probe. Additional flight calibration maneuvers were performed remote from the tower in homogeneous atmospheric conditions. System hardware and instrumentation are described and the calibration procedures discussed. Calibration and flight results are presented to illustrate the overall ability of the system to determine the three-component ambient wind fields during straight and level flight conditions.

Barrick, John D. W.↗