Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “surface tension”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 775 records · Page 43

The nature of melt process changes in microgravity

The effects on melt impurities of the lack of buoyancy-driven convection in melts and the gas phase are outlined. Probable effects noted are: retardation of convective flow by a thin adsorbed impurity layer because of surface tension gradients (Marangoni flow); changes in the transport of volatile impurities to the melt surface and the consequent reduction of evaporation; and the change in dependence of evaporation rates on pressure due to the absence of convective flow in the gas next to the melt.

Wilcox, W.↗

Impurity Extraction by Droplets

The goals are to model and to measure the phase equilibrium properties of a finely divided fluid containing a large number of chemically similar species. The objective is to develop an accurate, usable model for such phenomena as pollutant extraction of rain clouds, industrial separation in spray towers, and separation in emulsions. The project was designed as a hierarchy of complementary theoretical and experimental steps. A theory was developed to describe the segregation of complex impurities at the interface of a solvent. This phenomenon is important in phase behavior when a large fraction of molecules in a material are near an interface, the situation in a finely divided material. The theory will be modified to account for the effect of surface curvature on the surface tension. The study of mixtures differs from pure fluids not only because of the surface effects but also because composition differences between the droplet and the surrounding vapor can stabilize a droplet with respect to a bulk phase.

Morrison, G.↗

Biobriefcase aerosol collector

A system for sampling air and collecting particles entrained in the air that potentially include bioagents. The system comprises providing a receiving surface, directing a liquid to the receiving surface and producing a liquid surface. Collecting samples of the air and directing the samples of air so that the samples of air with particles entrained in the air impact the liquid surface. The particles potentially including bioagents become captured in the liquid. The air with particles entrained in the air impacts the liquid surface with sufficient velocity to entrain the particles into the liquid but cause minor turbulence. The liquid surface has a surface tension and the collector samples the air and directs the air to the liquid surface so that the air with particles entrained in the air impacts the liquid surface with sufficient velocity to entrain the particles into the liquid, but cause minor turbulence on the surface resulting in insignificant evaporation of the liquid.

47 OTHER INSTRUMENTATION↗

Supercritical CO2 Cleaning System for Planetary Protection and Contamination Control Applications

Current spacecraft-compatible cleaning protocols involve a vapor degreaser, liquid sonication, and alcohol wiping. These methods are not very effective in removing live and dead microbes from spacecraft piece parts of slightly complicated geometry, such as tubing and loosely fitted nuts and bolts. Contamination control practices are traditionally focused on cleaning and monitoring of particulate and oily residual. Vapor degreaser and outgassing bakeout have not been proven to be effective in removing some less volatile, hydrophilic biomolecules of significant relevance to life detection. A precision cleaning technology was developed using supercritical CO2 (SCC). SCC is used as both solvent and carrier for removing organic and particulate contaminants. Supercritical fluid, like SCC, is characterized by physical and thermal properties that are between those of the pure liquid and gas phases. The fluid density is a function of the temperature and pressure. Its solvating power can be adjusted by changing the pressure or temperature, or adding a secondary solvent such as alcohol or water. Unlike a regular organic solvent, SCC has higher diffusivities, lower viscosity, and lower surface tension. It readily penetrates porous and fibrous solids and can reach hard-to-reach surfaces of the parts with complex geometry. Importantly, the CO2 solvent does not leave any residue. The results using this new cleaning device demonstrated that both supercritical CO2 with 5% water as a co-solvent can achieve cleanliness levels of 0.01 mg/cm2 or less for contaminants of a wide range of hydrophobicities. Experiments under the same conditions using compressed Martian air mix, which consists of 95% CO2, produced similar cleaning effectiveness on the hydrophobic compounds. The main components of the SCC cleaning system are a high-pressure cleaning vessel, a boil-off vessel located downstream from the cleaning vessel, a syringe-type high-pressure pump, a heat exchanger, and a back pressure regulator (BPR). After soaking the parts to be cleaned in the clean vessel for a period, the CO2 with contaminants is flushed out of the cleaning vessel using fresh CO2 in a first-in-first-out (FIFO) method. The contaminants are either precipitating out in the boil-off container or being trapped in a filter subsystem. The parts to be cleaned are secured in a basket inside and can be rotated up to 1,400 rpm by a magnetic drive. The fluid flows within the vessel generate tangential forces on the parts surfaces, enhancing the cleaning effectiveness and shortening the soaking time. During the FIFO flushing, the pump subsystem pushes fresh CO2 into the cleaning vessel at a constant flow rate between 0.01 and 200 mL/min, while the BPR regulates the pressure in the cleaning vessel to within 0.1 bar by controlling the needle position in an outlet valve. The fresh CO2 gas flows through the heat exchanger at a given temperature before entering the cleaning vessel. A platinum resistance thermometer (PRT) reads the cleaning vessel interior temperature that can be controlled to within 0.1 K. As a result, cleaning vessel temperature remains constant during the FIFO flushing. There is no change in solvent power during FIFO flushing since both temperature and pressure inside the cleaning vessel remain unchanged, thus minimizing contaminants left behind. During decompression, both temperature and pressure are strictly controlled to prevent bubbles from generating in the cleaning vessel that could stir up the contaminants that sank to the bottom by gravity.

Lin, Ying↗

Methods of Fabricating a Layer of Metallic Glass-Based Material Using Immersion and Pouring Techniques

Systems and methods in accordance with embodiments of the invention implement layers of metallic glass-based materials. In one embodiment, a method of fabricating a layer of metallic glass includes: applying a coating layer of liquid phase metallic glass to an object, the coating layer being applied in a sufficient quantity such that the surface tension of the liquid phase metallic glass causes the coating layer to have a smooth surface; where the metallic glass has a critical cooling rate less than 1000 K/s; and cooling the coating layer of liquid phase metallic glass to form a layer of solid phase metallic glass.

Hofmann, Douglas↗

Containerless processing of hypermonotectic and glass forming alloys using the Marshall Space Flight Center 100 meter drop tube facility

Two separate projects were carried out to study alloys whose solidification structures can be strongly influenced by the presence of a container during melting and solidifications. One project involved containerless solidification of hypermonotectic Au35Rh65 alloys. This alloy exhibits liquid immiscibility over a temperature range. It has been suggested that containerless melting might be one solution to the problem of sedimentation in the dispersions of immiscible liquid phases. However, surface tension driven flows could also lead to accumulation of the minority liquid phase at the external surface of a containerlessly melted alloy. The research underway is a first step in determining the influence of containerless, microgravity processing on immiscible alloys. Nickel-niobium alloys were studied using the drop tube facility. One alloy in this system, a Ni60Nb40 alloy, is a good candidate for the formation of a bulk metallic glass. Amorphous alloys of this composition were produced using thin film and mechanical alloying techniques. However, theory indicates that if heterogeneous nucleation can be avoided, it should be possible to produce an amorphous structure in this system using a moderate cooling rate from the melt. The containerless melting and solidification capabilities of the drop tube faciltiy provide ideal conditions for a study of this type. To date, several Ni60Nb40 samples have been levitated, melted and cooled during 4.6 seconds of free fall in the 100 meter drop tube. Structures obtained are discussed.

Andrews, J. B.↗

Current status of liquid sheet radiator research

Initial research on the external flow, low mass liquid sheet radiator (LSR), has been concentrated on understanding its fluid mechanics. The surface tension forces acting at the edges of the sheet produce a triangular planform for the radiating surface of width, W, and length, L. It has been experimentally verified that (exp L)/W agrees with the theoretical result, L/W = (We/8)exp 1/2, where We is the Weber number. Instability can cause holes to form in regions of large curvature such as where the edge cylinders join the sheet of thickness, tau. The W/tau limit that will cause hole formation with subsequent destruction of the sheet has yet to be reached experimentally. Although experimental measurements of sheet emissivity have not yet been performed because of limited program scope, calculations of the emissivity and sheet lifetime is determined by evaporation losses were made for two silicon based oils; Dow Corning 705 and Me(sub 2). Emissivities greater than 0.75 are calculated for tau greater than or equal to 200 microns for both oils. Lifetimes for Me(sub 2) are much longer than lifetimes for 705. Therefore, Me(sub 2) is the more attractive working fluid for higher temperatures (T greater than or equal to 400 K).

Chubb, Donald L.↗

Dust-Tolerant Intelligent Electrical Connection System

Faults in wiring systems are a serious concern for the aerospace and aeronautic (commercial, military, and civilian) industries. Circuit failures and vehicle accidents have occurred and have been attributed to faulty wiring created by open and/or short circuits. Often, such circuit failures occur due to vibration during vehicle launch or operation. Therefore, developing non-intrusive fault-tolerant techniques is necessary to detect circuit faults and automatically route signals through alternate recovery paths while the vehicle or lunar surface systems equipment is in operation. Electrical connector concepts combining dust mitigation strategies and cable diagnostic technologies have significant application for lunar and Martian surface systems, as well as for dusty terrestrial applications. The dust-tolerant intelligent electrical connection system has several novel concepts and unique features. It combines intelligent cable diagnostics (health monitoring) and automatic circuit routing capabilities into a dust-tolerant electrical umbilical. It retrofits a clamshell protective dust cover to an existing connector for reduced gravity operation, and features a universal connector housing with three styles of dust protection: inverted cap, rotating cap, and clamshell. It uses a self-healing membrane as a dust barrier for electrical connectors where required, while also combining lotus leaf technology for applications where a dust-resistant coating providing low surface tension is needed to mitigate Van der Waals forces, thereby disallowing dust particle adhesion to connector surfaces. It also permits using a ruggedized iris mechanism with an embedded electrodynamic dust shield as a dust barrier for electrical connectors where required.

Lewis, Mark↗

Superior Metal‐Organic Framework Activation with Dimethyl Ether

Abstract Metal–organic frameworks (MOFs) are demonstrated to be readily activated by treatment with the low surface tension, low boiling point solvent dimethyl ether (DME). The mildness of the method enables access to high surface areas by avoiding structural changes in the framework that often plague thermal activation methods. A distinction from previous methods is that DME activation succeeds for materials with coordinatively unsaturated sites (CUS) and non‐CUS MOFs as well. DME displaces solvent molecules occupying the pores of the MOF as well as those coordinated to metal centers; reducing evacuation temperature by using a coordinating, yet highly volatile guest enables low temperature activation with structural retention as demonstrated surface area measurements that match or exceed existing activation protocols.

Wright, Keenan R.↗

Superior Metal‐Organic Framework Activation with Dimethyl Ether

Abstract Metal–organic frameworks (MOFs) are demonstrated to be readily activated by treatment with the low surface tension, low boiling point solvent dimethyl ether (DME). The mildness of the method enables access to high surface areas by avoiding structural changes in the framework that often plague thermal activation methods. A distinction from previous methods is that DME activation succeeds for materials with coordinatively unsaturated sites (CUS) and non‐CUS MOFs as well. DME displaces solvent molecules occupying the pores of the MOF as well as those coordinated to metal centers; reducing evacuation temperature by using a coordinating, yet highly volatile guest enables low temperature activation with structural retention as demonstrated surface area measurements that match or exceed existing activation protocols.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Marangoni bubble motion in zero gravity

It is shown experimentally that the Marangoni phenomenon is a primary mechanism for the movement of a gas bubble in a nonisothermal liquid in a low-gravity environment. In such two-phase flow systems, local variations in bubble surface tension are caused by a temperature gradient in the liquid. Shearing stresses thus generated at the bubble surface lead to convection in both media, as a result of which the bubble begins to move. A mathematical model consisting of the Navier-Stokes equations and the thermal energy equations, along with the appropriate boundary conditions for both media, is proposed.

Thompson, R. L.↗

Hort-Range Wetting at Liquid Gallium-Bismuth Alloy Surfaces: X-ray Measurements and Square-Gradient Theory

We present an x-ray reflectivity study of wetting at the free surface of the binary liquid metal alloy gallium-bismuth (Ga-Bi) in the region where the bulk phase separates into Bi-rich and Ga-rich liquid phases. The measurements reveal the evolution of the microscopic structure of the wetting films of the Bi-rich, low-surface-tension phase along several paths in the bulk phase diagram. The wetting of the Ga-rich bulk's surface by a Bi-rich wetting film, the thickness of which is limited by gravity to only 50 Angstroms, creates a Ga-rich/Bi-rich liquid/liquid interface close enough to the free surface to allow its detailed study by x rays. The structure of the interface is determined with Angstromsngstrem resolution, which allows the application of a mean-field square gradient model extended by the inclusion of capillary waves as the dominant thermal fluctuations. The sole free parameter of the gradient model, the influence parameter K, that characterizes the influence of concentration gradients on the interfacial excess energy, is determined from our measurements. This, in turn, allows a calculation of the liquid/liquid interfacial tension, and a separation of the intrinsic and capillary wave contributions to the interfacial structure. In spite of expected deviations from MF behavior, based on the upper critical dimensionality (Du = 3 ) of the bulk, we find that the capillary wave excitations only marginally affect the short-range complete wetting behavior. A critical wetting transition that is sensitive to thermal fluctuations appears to be absent in this binary liquid-metal alloy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Suppression of Marangoni Convection in Float Zones

The basic purpose of this program is to demonstrate by means of an Earth-based 1-g experiment that the undesirable Marangoni (surface tension) convection can be suppressed or significantly reduced by means of gas jets directed tangentially to the free surface of the liquid in a float zone. These jets will establish the tangential shear stress field over the surface which must be adjusted to equal the counter-stress resultant of the Marangoni shear stress which causes the convection. For proposed materials processing in space (o-g), particularly of important, highly reactive semiconductor materials, e.g., silicon, microgravity will virtually eliminate the unwanted thermal-buoyancy convection in the liquid silicon, but will have no effect in reducing the Marangoni convection. Unless this can be sufficiently suppressed by other means, there may be no significant advantages to the proposed space processing of reactive semiconductors. Although some inert gas such as argon must be used for the corrosive liquid silicon, the Earth-based experiment uses air jets and various transparent oils, since the basic principle involved is the same. The first float zone is enclosed in a very small rectangular box with a quasi-planar free surface. Stable Marangoni convection has been achieved and velocities measured photographically. The air jet system with variable velocity and temperature is under construction. Three independent parameters must be optimized to attain maximum suppression: the gas velocity, angle of attack, and gas temperature.

Dressler, R. F.↗

Chromite-Plagioclase Assemblages as a New Shock Indicator; Implications for the Shock and Thermal Histories of Ordinary Chondrites

Chromite in ordinary chondrites (OC) can be used as a shock indicator. A survey of 76 equilibrated H, L and LL chondrites shows that unshocked chromite grains occur in equant, subhedral and rounded morphologies surrounded by silicate or intergrown with metallic Fe-Ni and/or troilite. Some unmelted chromite grains are fractured or crushed during whole-rock brecciation. Others are transected by opaque veins; the veins form when impacts cause localized heating of metal-troilite intergrowths above the Fe-FeS eutectic (988 C), mobilization of metal-troilite melts, and penetration of the melt into fractures in chromite grains. Chromite-plagioclase assemblages occur in nearly every shock-stage S3-S6 OC; the assemblages range in size from 20-300 microns and consist of 0.2-20-micron-size euhedral, subhedral, anhedral and rounded chromite grains surrounded by plagioclase or glass of plagioclase composition. Plagioclase has a low impedance to shock compression. Heat from shock-melted plagioclase caused adjacent chromite grains to melt; chromite grains crystallized from this melt. Those chromite grains in the assemblages that are completely surrounded by plagioclase are generally richer in Al2O3, than unmelted, matrix chromite grains in the same meteorite. Chromite veinlets (typically 0.5-2 microns thick and 10-300 microns long) occur typically in the vicinity of chromite-plagioclase assemblages. The veinlets formed from chromite-plagioclase melts that were injected into fractures in neighboring silicate grains; chromite crystallized in the fractures and the residual plagioclase-rich melt continued to flow, eventually pooling to form plagioclase-rich melt pockets. Chromite-rich chondrules (consisting mainly of olivine, plagioclase-normative mesostasis, and 5-15 vol.% chromite) occur in many shocked OC and OC regolith breccias but they are absent from primitive type-3 OC. They may have formed by impact melting chromite, plagioclase and adjacent mafic silicates during higher-energy shock events. The melt was jetted from the impact site and formed droplets due to surface tension. Crystallization of these droplets may have commenced in flight, prior to landing on the parent-body surface. Chromite-plagioclase assemblages and chromite veinlets occur in 25 out of 25 shock-stage S1 OC of petrologic type 5 and 6 that I examined. Although these rocks contain unstrained olivine with sharp optical extinction, most possess other shock indicators such as extensive silicate darkening, numerous occurrences of metallic Cu, polycrystalline troilite, and opaque veins. It seems likely that these rocks were shocked to levels at least as high as shock-stage S3 and then annealed by heat generated during the shock event. During annealing, the olivine crystal lattices healed but other shock indicators survived. Published Ar-Ar age data for some SI OC indicate that many shock and annealing events occurred very early in the history of the parent asteroids. The common occurrence of shocked and annealed OC is consistent with collisions being a major mechanism responsible for metamorphosing OC.

Rubin, Alan E.↗

Development and Testing of Femtosecond Laser Surface Processing (FLSP) Treated Guide Vanes for Application to Advanced Cryogenic Liquid Acquisition Devices

Liquid Acquisition Devices (LADs) are used inside propellant tanks in microgravity to collect liquid propellant to move towards the sump or outlet of a tank during expulsion or transfer. In microgravity, vehicle thrusters can produce necessary phase separation, but in the absence of thrust, surface tension is the driver of fluid behavior. Liquid in microgravity will tend to form a sphere to minimize surface area. If a LAD can be made more “attractive” to a propellant (omniphilic), then it should perform its function more effectively. This paper presents preliminary results on using femtosecond laser surface processing (FLSP) to change the wetting properties of a vane LAD. FLSP can make metals superhydrophilic or omniphilic; by controlling the applied laser parameters, the resulting micro and nanoscale surface features can be tailored to control and optimize hydrophilic/omniphilic properties. Two LAD galleries with guide vanes were recently fabricated, a control sample and an FLSP-treated sample. The LADs were ground tested and also implemented in a parabolic flight experiment. Based on contact angle and roll-off angle measurements of the surface-treated vane, FLSP appears to be a promising technique to improve efficiency of LADs

Liquid Acquisition Devices↗

A variational approach to the study of capillary phenomena

The problem of determining the free surface of a liquid in a capillary tube, and of a liquid drop, sitting first on a horizontal plane and then on more general surfaces is considered. With some modifications, the method applies to the study of pendent drops and of rotating drops as well. The standard capillary problem, i.e. the determination of the free surface of a liquid in a thin tube of general cross section, which resuls from the simultaneous action of surface tension, boundary adhesion and gravity is discussed. It turns out that in this case the existence of the solution surface depends heavily on the validity of a simple geometric condition about the mean curvature of the boundary curve of the cross section of the capillary tube. Some particular examples of physical interest are also be discussed. Liquid drops sitting on or hanging from a fixed horizontal plane are discussed. The symmetry of the solutions (which can actually be proved, as consequence of a general symmetrization argument) now plays the chief role in deriving both the existence and the regularity of energy-minimizing configurations. When symmetry fails (this is the case, for example, when the contact angle between the drop and the plate is not constant, or when the supporting surface is not itself symmetric), then more sophisticated methods must be used. Extensions in this direction are outlined.

Emmer, M.↗

Fluorographite-co-polydimethylsiloxane coated polyvinylidene-fluoride membrane for desalination of highly saline water with humic acid in direct contact membrane distillation

Highlights: • Surface modifications by FGi particles with PDMS binder of PVDF microporous membranes shown improvement in DCMD. • LEP with DI water & performance of M2-M4 modified membranes in DCMD was enhanced with 1M NaCl & 10 ppm HA feed solution. • Amphiphobicity was evidenced by CA with low surface tension liquids upto 38 dyne/cm as well as with canola oil. • EDX analysis proved enhancement in FC ratio and membrane surface analysis lead to understand enhanced performance in DCMD. Membranes with amphiphobic properties are crucial for desalination of concentrated saline water with organic foulant by membrane distillation. In this research, we coated Fluorographite (FGi) particles on polyvinylidene-fluoride (PVDF) flat sheet membranes with 0.8% v/v polydimethylsiloxane (PDMS) as binder by filtration coating method. We evaluated its amphiphobicity via contact angles which were observed by DI water, canola oil and organic solutions as mimicking for oleophobicity. Surface modifications by FGi particles on the surface of membranes was introduced with PDMS binder which brought bifunctionality of amphiphobicity to enhance hydrophobicity and oleophobicity. We also investigated performance of coated membranes in direct contact membrane distillation (DCMD) with 1 molar concentrated NaCl solution along with humic acid being organic foulant and compared with virgin membrane (M1 membrane) and Liquid entry pressure (LEP) was also evaluated. LEP was measured by dynamic method which shown considerable improvement in coated membranes. M3 membrane showed overall better performance in terms of salt rejection higher than 99.87% and flux as compared to M1 membrane. Furthermore, the evaluation of surface characterizations was done by FESEM with EDX, AFM and FTIR. Surface morphology confirmed the coating of FGi on membrane surface while EDX evidenced increase in atomic percent of fluorine in turn F:C ratio.

54 ENVIRONMENTAL SCIENCES↗